Andeman EPOWER-199 Car Jump Starter, 4000A Battery Up to 10L

Product's Documents

Below are documents related to this product, you can read online or download:
EPOWER-199 photo

User Manual

This is the main product document for model EPOWER-199.

The file format is pdf, 13 pages, you can download this manual here .

background
Epower-199
MODEL
JUMP S
T
ARTER
MULTI-FUNCTION
Jump Starter
Power bank
Car electronics
Torch
User Manual
Name VISHTEC ltd
Add 3 rd floor office 5, Plovdiv 2 Liuben
Karavelov bul, 4002 Bulgaria
Email compliance@vish-tec.com
Phone +359 32 540 357
Name VISHTEC UK Co.,Ltd
Add 275 ISLINGTON SUITE 1405 NEW NORTH
ROAD LONDON ENGLAND N1 7AA
Email Vincent.feng@vish-tec.com
Phone + 44 1584 879 384
background
ENGLISH
PRODUCT OVERVIEW
Display Screen
Power Button: Turn on the activation host and long
press to turn on the light
BOOST Button Force start (2S on)
USB-C PD/SC 65W Input/Output Port
5V/2.4A Output Port
5V/9V/12V Output Port
15V/10A DC Output Port
12V DC Output Port (OUT, MAX 4000A)
Flashlight
1.
2.
3.
4.
5.
6.
7.
8.
9.
1
2
3
4
6
7
5
8
9
001
CATALOG
ENGLISH 001-011
DEUTSCH 012-022
FRANÇAIS 023-033
ESPAÑOL 045-055
POLSKI 034-044
ITALIANO 056-066
ČEŠTINA 067-077
background
ENGLISH ENGLISH
PACKAGE CONTENTS HOW TO USE
DO NOT jump start the vehicle if less than 60%
Insert the jump cable into the booster and connect the clamps to the car battery. (Red to positive/Black to
negative)
The screen displays“START, (WARNING: The device works normally only when displays START”)
01.
02.
03.
Epower-199 ×1 12V Needle-Nose
Battery Clamps ×1
cigarette lighter ×1
USB-C Cable(IN/OUT) ×1
Adapter x 1
User Manual ×1 Accessories Bag
Essential Version
002 003
background
ENGLISH ENGLISH
PACKAGE CONTENTS HOW TO USE
DO NOT jump start the vehicle if less than 60%
Insert the jump cable into the booster and connect the clamps to the car battery. (Red to positive/Black to
negative)
The screen displays“START”, (WARNING: The device works normally only when displays “START”)
01.
02.
03.
Epower-199 ×1 12V Needle-Nose
Battery Clamps ×1
cigarette lighter ×1
USB-C Cable(IN/OUT) ×1
Adapter x 1
User Manual ×1 Accessories Bag
Essential Version
002 003
background
ENGLISH ENGLISH
Epower-199 is designed to jump start 12-volt
ead-acid batteries,if your battery is too low,the
Epower-199 will be no“START”display. You can press
the BOOST button for 2 seconds to activate
“Override mode”.
WARNING: Disable safety protection and manually
forces "OVERRIDE MODE" ,Only for use when a
battery voltage is too low to be detected
1. Battery power percentage
2. Start
3. Stop
4. Reverse connection
5. DC
6. USB input/output
7. USB
HOW TO USE THE OVERRIDE MODE
DISPLAY SCREEN DESCRIPTION
SPECIFICATIONS
1
2
3
4
5
67
Performance index Performance index Specifications
L × W × H (mm)
Internal Battery
Peak current
Battery Capacity
Input USB-C
Output USB-C
Output USB
Output DC
Working Temperature
Charging Temperature
Storage Temperature
233x100x42
Lithium Ion
4000A
88.8Wh
USB-C PD/SC65W
USB-C PD/65W
Quick Charge(5V/9V/12V);5V/2.4A;
15V/10A
14°F to 140°F
32°F to 113°F
-4°F to 122°F
Dimensions
Main Parameters
004 005
background
ENGLISH ENGLISH
Epower-199 is designed to jump start 12-volt
ead-acid batteries,if your battery is too low,the
Epower-199 will be noSTARTdisplay. You can press
the BOOST button for 2 seconds to activate
Override mode.
WARNING: Disable safety protection and manually
forces "OVERRIDE MODE" ,Only for use when a
battery voltage is too low to be detected
1. Battery power percentage
2. Start
3. Stop
4. Reverse connection
5. DC
6. USB input/output
7. USB
HOW TO USE THE OVERRIDE MODE
DISPLAY SCREEN DESCRIPTION
SPECIFICATIONS
1
2
3
4
5
67
Performance index Performance index Specifications
L × W × H (mm)
Internal Battery
Peak current
Battery Capacity
Input USB-C
Output USB-C
Output USB
Output DC
Working Temperature
Charging Temperature
Storage Temperature
233x100x42
Lithium Ion
4000A
88.8Wh
USB-C PD/SC65W
USB-C PD/65W
Quick Charge(5V/9V/12V);5V/2.4A;
15V/10A
14°F to 140°F
32°F to 113°F
-4°F to 122°F
Dimensions
Main Parameters
004 005
background
ENGLISH ENGLISH
HOW TO CHARGE THE EPOWER-199
1. Plug the wall charger into the universal socket.
2. Plug the end of the wall charger into the USB-C input
port of Epower-199.
LED INLIGHT
FAQ
Recharge Time Charger Rating
With Wall Charger
Press and hold the power button for 6 seconds to turn
it off.
Note that Epower-199 is able to detect its own battery
status and can take steps to save power, such as going
into sleep mode when the battery is very low.
1.Q: How do I turn off Epower-199?
1. Plug the USB-C cable into the USB-C Port of the device.
2. Plug the other end of the USB-C cable into an external
power supply.
Short press to turn on, long press for 2 seconds to turn on the
light, and then short press to switch the mode,
The modes are as follows: low light, high light, white light
flashing, SOS, red light flashing quickly.
Press and hold the BOOST button for 2 seconds to turn on
the forced ignition, and press and hold for 6 seconds to turn
off.
With External Power Supply
LIGHT MODES
1. Plug the car charger into the input port of the device.
2. Plug the car charger into the cigarette adapter of your
car.
With Car Charger (Optional) How to turn on low current output mode
16h
8h
4h
1.5h
5W
10W
20W
65W
A:
If left in storage, the battery will hold its charge for
around 2 years. However, it's recommended that you
charge it a little bit every three months, as this will
prolong the overall lifespan of the battery
2.Q: When fully charged, how long will charge
remain in the battery when Epower-199 is not in
use?
A:
It takes around 1.5 hours to fully charge the battery
using a 65W USB PD charger.
3.Q: How long does it take to recharge Epower-199's
battery from flat?
A:
It could last for around five years if kept in good
condition. The battery should support around 500
recharges from 0 to 100%.
4. Q: What is expected lifespan of Epower-199?
A:
Yes, Epower-199 includes both standard USB and
USB-C output ports. You can charge any mobile
device simply by connecting it to one of these two
ports. For high-power charging via the USB-C port,
a cable that supports fast charging will be required.
For more information on output current and voltage,
see page 6.
5.Q: Can I use Epower-199 to charge my phone
or tablet?
A:
006 007
Double-click the power button to turn on the low current
output mode, and then double-click the power button to
turn off
background
ENGLISH ENGLISH
HOW TO CHARGE THE EPOWER-199
1. Plug the wall charger into the universal socket.
2. Plug the end of the wall charger into the USB-C input
port of Epower-199.
LED INLIGHT
FAQ
Recharge Time Charger Rating
With Wall Charger
Press and hold the power button for 6 seconds to turn
it off.
Note that Epower-199 is able to detect its own battery
status and can take steps to save power, such as going
into sleep mode when the battery is very low.
1.Q: How do I turn off Epower-199?
1. Plug the USB-C cable into the USB-C Port of the device.
2. Plug the other end of the USB-C cable into an external
power supply.
Short press to turn on, long press for 2 seconds to turn on the
light, and then short press to switch the mode,
The modes are as follows: low light, high light, white light
flashing, SOS, red light flashing quickly.
Press and hold the BOOST button for 2 seconds to turn on
the forced ignition, and press and hold for 6 seconds to turn
off.
With External Power Supply
LIGHT MODES
1. Plug the car charger into the input port of the device.
2. Plug the car charger into the cigarette adapter of your
car.
With Car Charger (Optional) How to turn on low current output mode
16h
8h
4h
1.5h
5W
10W
20W
65W
A:
If left in storage, the battery will hold its charge for
around 2 years. However, it's recommended that you
charge it a little bit every three months, as this will
prolong the overall lifespan of the battery
2.Q: When fully charged, how long will charge
remain in the battery when Epower-199 is not in
use?
A:
It takes around 1.5 hours to fully charge the battery
using a 65W USB PD charger.
3.Q: How long does it take to recharge Epower-199's
battery from flat?
A:
It could last for around five years if kept in good
condition. The battery should support around 500
recharges from 0 to 100%.
4. Q: What is expected lifespan of Epower-199?
A:
Yes, Epower-199 includes both standard USB and
USB-C output ports. You can charge any mobile
device simply by connecting it to one of these two
ports. For high-power charging via the USB-C port,
a cable that supports fast charging will be required.
For more information on output current and voltage,
see page 6.
5.Q: Can I use Epower-199 to charge my phone
or tablet?
A:
006 007
Double-click the power button to turn on the low current
output mode, and then double-click the power button to
turn off
background
ENGLISH ENGLISH
TOXIC AND HAZARDOUS SUBSTANCES
TROUBLESHOOTING
TOXIC AND HARMFUL SUBSTANCES
Problem Solution
SAFETY INSTRUCTIONS
Lead (Pb)
Indicate all homogeneous materials’ hazardous substances content are below the MCV limit specified in the
Standard 2002/95/EC(RoHs).
If the following operations can not solve your problems, please stop using the device and contact the
manufacture with E-mail
Mercury (Hg) Cadmium (Cd)
Hexavalent
Chromium
(Cr (Vi))
Polybrominated
Biphenyls (PBB)
Polybrominated
Diphenyl Ethers
(PBDE)
No response when pressing
the power button
The voltage of the Epower-199 is really low and triggers the low power protection
to shut down the device. Plug the wall charger into the Epower-199 to recharge it.
Make sure the power switch is in the on position.
Check that jump-starter is full charged. Recharge unit if necessary.
Make sure a proper polarity cable connection has been established.
Make sure the USB Charging Port Power Button is in the on position.
Check that Jump-Starter has a full charge. Recharge unit if necessary
1. Read the user manual carefully before using this device.
2. Do not use this device as a car battery.
3. Do not use this device as a toy.
4. Be careful to use it when there are children around to avoid injury.
Unit fails to jump-start
USB power port fails to power
008 009
background
ENGLISH ENGLISH
TOXIC AND HAZARDOUS SUBSTANCES
TROUBLESHOOTING
TOXIC AND HARMFUL SUBSTANCES
Problem Solution
SAFETY INSTRUCTIONS
Lead (Pb)
Indicate all homogeneous materials hazardous substances content are below the MCV limit specified in the
Standard 2002/95/EC(RoHs).
If the following operations can not solve your problems, please stop using the device and contact the
manufacture with E-mail
Mercury (Hg) Cadmium (Cd)
Hexavalent
Chromium
(Cr (Vi))
Polybrominated
Biphenyls (PBB)
Polybrominated
Diphenyl Ethers
(PBDE)
No response when pressing
the power button
The voltage of the Epower-199 is really low and triggers the low power protection
to shut down the device. Plug the wall charger into the Epower-199 to recharge it.
 Make sure the power switch is in the on position.
 Check that jump-starter is full charged. Recharge unit if necessary.
 Make sure a proper polarity cable connection has been established.
 Make sure the USB Charging Port Power Button is in the on position.
 Check that Jump-Starter has a full charge. Recharge unit if necessary
1. Read the user manual carefully before using this device.
2. Do not use this device as a car battery.
3. Do not use this device as a toy.
4. Be careful to use it when there are children around to avoid injury.
Unit fails to jump-start
USB power port fails to power
008 009
background
ENGLISH
WARNING
!
The product only works with 12V battery.
Use the clamps that come with the device. When the clamp or wire is damaged, stop using it immediately to avoid personal
injuries caused by fire or electric shock.
Do not connect the positive and negative clamps to each other.
Before starting, make sure there is no rust or foreign matter on the interface. Connect the device with the clamp tightly to
make sure the device starts properly.
Remove the clamps from the car battery within 30 seconds after successfully starting the car. Otherwise, it may cause
damage.
Do not start the device more than three times in a row, and the interval between each start should be at least two minutes,
otherwise the product will be overheated and damaged.
Do not use the clamps to power other devices.
Do not place the device in an environment where the temperature exceeds 140°F.
The device shall be charged at a temperature of 32°F to 113°F.
Do not put the device in water or expose it to rain.
Do not expose the device to high temperature or fire.
Do not use the device in explosive environment with flammable liquid, gas or dust.
Make sure that someone around is available to help you when using the device.
Do not wear metal jewelry such as rings, bracelets, and necklaces while using the device.
Disconnect the jump starter and the clamp at the battery clamp plug to reduce the risk of damage to the power plug and
power cord.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
ENGLISH
Do not use damaged or modified battery packs to avoid the danger of fire, explosion, and injury.
Use the original charger or a charger with the same input terminal as the jumper starter to charge.
Do not charge this device immediately after starting the car.
Do not start the car while charging the device.
The battery may leak in extreme cases. Do not touch the leaked liquid directly with your hands or skin. Rinse immediately
with soap and water in case of contact. If the leaked liquid comes into contact with your eyes, rinse your eyes with cold
water for at least 10 minutes and seek medical advice immediately.
At the end of the product life, lithium battery should be disposed in accordance with local regulations.
If your car battery is in low voltage(below 8V), press the power button and the LED button of the jump starter simultaneous-
ly for 3 seconds to force start your car.
This product is for 12-Voltage vehicle (equipment) batteries. It may be dangerous if used with other types of batteries. Read
and understand the safety instructions before using the jump starter. Fail to follow the safety instructions may cause damage
to the jump starter, and may also result in electric shock, explosions, fire, property damage, and personal injury.
20.
21.
22.
23.
24.
25.
26.
010 011
background
ENGLISH
WARNING
!
The product only works with 12V battery.
Use the clamps that come with the device. When the clamp or wire is damaged, stop using it immediately to avoid personal
injuries caused by fire or electric shock.
Do not connect the positive and negative clamps to each other.
Before starting, make sure there is no rust or foreign matter on the interface. Connect the device with the clamp tightly to
make sure the device starts properly.
Remove the clamps from the car battery within 30 seconds after successfully starting the car. Otherwise, it may cause
damage.
Do not start the device more than three times in a row, and the interval between each start should be at least two minutes,
otherwise the product will be overheated and damaged.
Do not use the clamps to power other devices.
Do not place the device in an environment where the temperature exceeds 140°F.
The device shall be charged at a temperature of 32°F to 113°F.
Do not put the device in water or expose it to rain.
Do not expose the device to high temperature or fire.
Do not use the device in explosive environment with flammable liquid, gas or dust.
Make sure that someone around is available to help you when using the device.
Do not wear metal jewelry such as rings, bracelets, and necklaces while using the device.
Disconnect the jump starter and the clamp at the battery clamp plug to reduce the risk of damage to the power plug and
power cord.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
ENGLISH
Do not use damaged or modified battery packs to avoid the danger of fire, explosion, and injury.
Use the original charger or a charger with the same input terminal as the jumper starter to charge.
Do not charge this device immediately after starting the car.
Do not start the car while charging the device.
The battery may leak in extreme cases. Do not touch the leaked liquid directly with your hands or skin. Rinse immediately
with soap and water in case of contact. If the leaked liquid comes into contact with your eyes, rinse your eyes with cold
water for at least 10 minutes and seek medical advice immediately.
At the end of the product life, lithium battery should be disposed in accordance with local regulations.
If your car battery is in low voltage(below 8V), press the power button and the LED button of the jump starter simultaneous-
ly for 3 seconds to force start your car.
This product is for 12-Voltage vehicle (equipment) batteries. It may be dangerous if used with other types of batteries. Read
and understand the safety instructions before using the jump starter. Fail to follow the safety instructions may cause damage
to the jump starter, and may also result in electric shock, explosions, fire, property damage, and personal injury.
20.
21.
22.
23.
24.
25.
26.
010 011
background
Epower-199
MODEL
JUMP S
T
ARTER
MULTI-FUNCTION
Jump Starter
Power bank
Car electronics
Torch
User Manual
Name VISHTEC ltd
Add 3 rd floor office 5, Plovdiv 2 Liuben
Karavelov bul, 4002 Bulgaria
Phone +359 32 540 357
Name VISHTEC UK Co.,Ltd
Add 275 ISLINGTON SUITE 1405 NEW NORTH
ROAD LONDON ENGLAND N1 7AA
Phone + 44 1584 879 384

Specifications

Andeman EPOWER-199 Questions and Answers