This owner’s manual was updated July 2024This owner’s manual was updated July 2024This owner’s manual was updated July 2024This owner’s manual was updated July 2024
* Installer: Leave this manual with the proud new owner *
Renaissance Cooking Systems
Owner’s Manual
For Residential Use Only
America's Best Value in Outdoor Kitchen Equipment
Installation, Operation, Maintenance
Instructions & Parts List
Models:
RVH36A & RVH48B
This owner’s manual was updated August 2025
For the latest news, recipes and cooking tips for your new
Renaissance Cooking Systems vent hood, check out www.RCSGasGrills.com

VENT HOOD
INSTALLATION INSTRUCTIONS & OWNERS MANUAL
36” VENT HOOD WITH SINGLE MOTOR
48” VENT HOOD WITH DUAL MOTOR
NAME:
RVH36A
RVH48B
PART #:
INSTALLER
Please leave this manual for the owner
Serial Number:
Model:
Date of Purchase:
Place of Purchase:

EXPLODED VIEW & REPLACEMENT PARTS LIST
3
4
2
1
13
11
10
7
5
8
6
9
12
7
ITEM # DESCRIPTION
RVH36A RVH48B
PART NO. QTY PART NO. QTY
1 1/2” MOUNTING TEMPLATE 11367 1 11369 1
2 4’’ VENT HOOD SPACER (optional) 11371 1 11373 1
**2a 8’’ VENT HOOD SPACER (optional) 11375 1 11377 1
3 DUCT COVER (optional) 11379 1 11381 1
4 VENT HOOD ASSEMBLY 11383 1 11385 1
5 KNOB 11344 2 11344 3
6 LIGHT CONTROLLER 11387 1 11387 1
7 FAN CONTROLLER 11343 1 11343 2
8 LED LIGHT 11388 2 11388 4
9 BAFFLE FILTER - 12” 11389 3 11389 4
10 BLOWER PLATE 11398 1 11398 2
11 1000 CFM BLOWER 11290 1 11290 2
12 GREASE TUBE 11393 1 11395 1
13 TRANSITION COLLAR FOR 8” VENT 11397 1 11397 2
**14 CAPACITOR 11342 1 11342 1
** NOT SHOWN
3
VENT HOOD USER MANUAL

IMPORTANT SAFETY INSTRUCTIONS
1. Never leave surface units unattended at high
settings.
2. Oil-overs can cause smoking and may ignite.
Heat oils slowly on low heat.
3. Always turn hood ON five minutes prior to
cooking to begin airflow.
4. Clean ventilation filters frequently. DO NOT
ALLOW GREASE TO ACCUMULATE ON FAN
OR FILTER.
5. Use proper pan size. Always use cookware
appropriate for the size of the burner or
element.
TO REDUCE THE RISK OF RANGE TOP
GREASE FIRE, PLEASE OBSERVE THE
FOLLOWING:
• Vent Hoods are for residential use only!
• For general ventilation use only. Do not use to
exhaust hazardous or explosive materials or
vapors
• Use this unit only in the manner intended by
the manufacturer.
• Before servicing or cleaning this unit, switch
power off at service panel and lock the panel
to prevent power from being switched on by
accident. If the service panel cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
• Remove all rings, watches, belt buckles, jewelry and
any clothing with metal buttons or snaps to prevent
damage to hood.
• DO NOT REMOVE HOOD FROM ITS ORIGINAL
CARTON UNTIL YOU ARE READY TO INSTALL IT.
• When you are ready to begin the installation
process, remove the hood from its carton and place
it on a clean soft blanket.
• Inspect the hood carefully for any damage or
imperfections before you begin to install the hood.
If any damage or imperfections exist, re-carton the
hood and call your dealer IMMEDIATELY. Do not
install a damaged hood.
• It is highly recommended that rubber gloves be
used to prevent scratches on the hood and to
provide you with a firm grip.
• When removing the hood from the carton, locate
the filters. The filters are not pre -installed in the
hood. The filters are in a box marked filters inside
the hood carton.
• Model hood series can be ducted to the top or the
rear. Check product guide for additional transitions,
wall caps and roof caps.
• All ventilation hoods have a variable speed control
blower switch.
• To avoid damage that will not be covered
under warranty make sure blowers are
free from obstructions (packing and
debris) prior to running the blowers. Test
run blowers before finalizing installation.
Check with manufacturer before
attempting to use blower systems other
than blower systems.
WARNING
HANDLING PRECAUTIONS
NOTE TO THE INSTALLER
WARNING
WARNING
4. DO NOT USE WATER, including wet dishcloths
or towels - a violent steam explosion may
result.
USE AN EXTINGUISHER ONLY IF:
• You know you have a class ABC extinguisher
and you already know how to operate it.
• The fire is small and contained in the area
where it started.
• The fire department is being called.
IN THE EVENT OF RANGE TOP GREASE
FIRE, OBSERVE THE FOLLOWING:
1. Smother the flames with a close-fitting
lid, cooking sheet or other metal tray, and
then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN.
3. MAKE SURE YOUR VENTILATION SYSTEM IS
COMPLETELY TURNED OFF. DO NOT TURN
HOOD ON TO TRY AND EVACUATE SMOKE.
4
VENT HOOD USER MANUAL

CLEANING AND MAINTENANCE
INSPECT ALL MOLDED PACKAGING AND
BOXES FOR PARTS BEFORE DISCARDING.
ANY DAMAGE MUST BE REPORTED BEFORE
INSTALLING THE HOOD. ONCE THE HOOD
HAS BEEN INSTALLED, NO RETURN WILL
BE ACCEPTED.
WARNING
Your hood will not function properly
if not
cleaned regularly and maintained properly.
Clean the filters regularly (at least twice a
month or every 24 hours of use) by soaking
them in soapy water and rinsing them in the
dishwasher at the normal cycle. When the
filters are removed, the accessible interior
of the canopy can be cleaned of grease, again
using only soap and water. Burned out LED
light bulbs are exchanged in the same way as
normal light bulbs. Make sure to only replace
them with the same type and wattage.
Make it a habit to turn on the hood on low
speed even when you are only boiling water.
The cleaning of the outside of the hood
depends on the material used as a decorative
exterior. For stainless steel and powder coated
metals, clean with soap and water only. Do not use
abrasive or aggressive chemicals! Check the
outside end of the duct at least once a year. If you
have an insect screen installed in the duct
termination, make sure that it is not broken or
dislocated. Filters are dishwasher safe or you may
hand wash them with warm soapy water.
PLANNING THE LOCATION FOR YOUR
VENT HOOD
Select the proper height to mount the hood. Take
into consideration the stature of the person or
persons who will be cooking. If mounted at a
height greater than 32” above the cooking surface,
the hood should be at least 6” wider than the
cooking appliance to provide a proper capture of
heat and grease. (Refer to the range
manufacturer’s guidelines) Once the proper height
is established, draw a level line where the bottom
of the hood will rest. If practical, mount a board
equal to the width of the hood along the line so you
may rest the hood on it while installing. Mark a
centerline on the wall equal to the entire height of
the hood to assist with the proper duct alignment
and hood placement. Determine stud location and
mark it clearly. If only one stud can be located,
toggle bolts or additional fastening must be
installed to firmly secure the hood to the wall.
.
5
VENT HOOD USER MANUAL

VENTING REQUIREMENTS & SPECIFICATIONS
VENTING REQUIREMENTS IMPORTANT:
SPECIFICATIONS:FOR THE MOST EFFICIENT & QUIET
OPERATION:
• Do not terminate the vent system in an attic or
other enclosed area.
• Do not use 4” (10.2 cm) laundry-type wall caps.
• Use metal/aluminum vent only. Rigid metal/
aluminum vent is recommended.
• Do not use plastic vent.
• Always keep the vent clean to ensure proper
airflow.
• Calculate the following figures before installation:
o Distance from the floor to the ceiling
o Distance from grill’s cooking surface to
vent hood
o Height of hood and vent cover
• A minimum distance of 32” is recommended* between
the grill’s cooking surface and bottom of vent hood.
• It is recommended that the vent hood be vented
vertically through the roof
• Venting size should be uniform.
• Do not use plastic vent.
• Use no more than three 90° elbows.
• Make sure there is a minimum of 24” of straight vent
between the elbows if more than one elbow is used.
• Do not install two elbows together.
• The length of vent system and number of elbows
should be kept to a minimum to provide efficient
performance.
• Use aluminum foil tape to seal all joints in the vent
system.
• Use caulking to seal exterior wall or roof opening
around the cap. USE 8” ROOF OR WALL VENT CAP
MINIMUM.
• A minimum 8-inch round vent (standard for this vent
hood) must be used to maintain maximum airflow
efficiency.
• Always use rigid type metal/aluminum vents if
available to maximize airflow.
• It is important to install the hood at the proper
mounting height. Hoods mounted too low could
result in heat damage and fire hazard; while hoods
mounted too high will be hard to reach and will lose
its performance and efficiency.
• Refer to the grill manufacturer’s height clearance
requirements and recommended vent hood mounting
height.
Voltage: 120v / 60 hz
Power: 492 W
Motor: 2 x 240 W
LED: 3 W
Venting: Top Vent or Rear
Vent Vent Size: 8 in. diameter
# of Vents:
• 1 (for 36” model)
• 2 (for 48" model)
6
VENT HOOD USER MANUAL

INSTALLATION
7
VENT HOOD USER MANUAL

VENT HOOD DIMENSIONS
MODEL #
A
B C
RVH48B 48” 203/8” 1313/16”
DIMENSIONS - RVH48B
8
VENT HOOD USER MANUAL

DIMENSIONS - RVH36A
VENT HOOD DIMENSIONS
MODEL # WIDTH DEPTH HEIGHT
RVH36A 36” 30” 18”
9
VENT HOOD USER MANUAL

WIRING DIAGRAM
*Number of lights varies between sizes
10
VENT HOOD USER MANUAL

Product Warranty
RCS is proud to provide the industries most comprehensive warranty program.
All RCS American Renaissance Grills, Cutlass Pro Series Grills and Cutlass Pro
Series side burners, sinks, briquette trays, as well as ALL doors and drawers are
warrantied to be free from manufacturer defects for the lifetime of the
original owner.
All RCS Premier Series Grills and Premier Series Side Burners are warrantied to be
free from manufacturer defects for 15 years to the original owner.
All RCS Refrigeration products are warrantied to be free from manufacturer
defects for 7 years to the original owner.y
All other products carry a one-year warranty to the original owner.
This RCS warranty is effective for product sales beginning April 14th, 2025.
For service assistance, please reach out to us at the website below.
This warranty excludes normal surface corrosion, discoloration, surface
scratches and surface rust which may occur. Improper maintenance, salt
spray, chemicals, pesticides will affect the look and integrity of the
components of these products. RCS will not be responsible for any damage
caused as a result of not following owner’s manual instructions. This non-
transferrable warranty is limited to the replacement of original (one-time)
defective parts, does not include shipping and labor to remove or install
replacement parts, if necessary. The owner must retain and submit their
original receipt with any warranty claim to receive warranty parts. The
warranty applies to the original owner only. Coverage is for residential use
only, no commercial applications apply.
For more information, questions or assistance please visit us at
RCSGasGrills.com and click the Customer Care Form.
REV.
04/12/202
5
REV. 04/12/2025REV. 04/12/2025
REV. 04/12/2025