MBVK***P1X00
BLOWER CABINET
INSTALLATION INSTRUCTIONS
is a registered trademark of Maytag Corporaon or its related companies and is used under license. All rights reserved.
© 2026
Daikin Comfort Technologies Manufacturing, Inc.
19001 Kermier Rd., Waller, TX 77484
www.daikincomfort.com - www.goodmanmfg.com - www.amana-hac.com
P/N: IO-438G Date: January 2026
WARNING
Do not bypass safety devices.
ONLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL,
ADJUST, SERVICE, MAINTENANCE OR REPAIR
(HEREINAFTER, “SERVICE”) THE EQUIPMENT SPECIFIED IN
THIS MANUAL SHOULD SERVICE THE EQUIPMENT.
THIS EQUIPMENT IS NOT INTENDED FOR USE BY
PERSONS (INCLUDING CHILDREN) WITH REDUCED
PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK
OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE
BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERN-
ING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE
FOR THEIR SAFETY.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT
THEY DO NOT PLAY WITH THE EQUIPMENT.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR
ANY INJURY OR PROPERTY DAMAGE ARISING FROM
IMPROPER SUPERVISION, SERVICE OR SERVICE
PROCEDURES. IF YOU SERVICE THIS UNIT, YOU ASSUME
RESPONSIBILITY FOR ANY INJURY OR PROPERTY
DAMAGE WHICH MAY RESULT. IN ADDITION, IN
JURISDICTIONS THAT REQUIRE ONE OR MORE LICENSES
TO SERVICE THE EQUIPMENT SPECIFIED IN THIS
MANUAL, ONLY LICENSED PERSONNEL SHOULD SERVICE
THE EQUIPMENT. IMPROPER SUPERVISION, INSTALLA-
TION, ADJUSTMENT, SERVICING, MAINTENANCE OR RE-
PAIR OF THE EQUIPMENT SPECIFIED IN THIS MANUAL, OR
ATTEMPTING TO INSTALL, ADJUST, SERVICE OR REPAIR
THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT
PROPER SUPERVISION OR TRAINING MAY RESULT IN
PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.
WARNING
NOTICE
IF AN “EC” ERROR IS ENCOUNTERED ON STARTUP, VERIFY
THAT THE ELECTRIC HEATER DIP SWITCHES HAVE BEEN SET TO
THE APPROPRIATE HEATER SIZE. SEE PAGES 7 AND 8 FOR THE
HEATER KIT AIRFLOW DELIVERY AND DIP SWITCH SETTINGS.
QUEBEC DISCLOSURE REGARDING AVAILABILITY
OF REPLACEMENT PARTS, REPAIR SERVICES AND
INFORMATION FOR MAINTENANCE AND REPAIR:
Daikin Comfort Technologies Manufacturing,
Inc. (Daikin) does not guarantee the availability
of (1) replacement parts; (2) repair services; and
(3) information necessary to maintain or repair
products, within the meaning of section 39.1 of
the Consumer Protection Act, CQLR, c P-40.1 and
section 79.18 of the Regulation respecting the
application of the Consumer Protection Act, CQLR,
c P-40.1, r. 3.
AVIS POUR LE QUÉBEC CONCERNANT LA
DISPONIBILITÉ DES PIÈCES DE RECHANGE,
DES SERVICES DE RÉPARATION ET DES
RENSEIGNEMENTS POUR L’ENTRETIEN ET LA
RÉPARATION : Daikin Comfort Technologies
Manufacturing, Inc. (Daikin) ne garantit pas la
disponibilité (1) des pièces de rechange, (2) des
services de réparation et (3) des renseignements
pour l’entretien et la réparation, au sens de
l’article 39.1 de la Loi sur la protection du
consommateur, RLRQ c P-40.1 et de l’article
79.18 du Règlement d’application de la Loi sur la
protection du consommateur, RLRQ c P-40.1, r 3.

2
Introduction............................................................................ 2
Electrostatic Discharge (ESD) Precautions ............................ 2
Checking Product Received ...................................................... 2
Replacement Parts ................................................................... 2
Ordering Parts ........................................................................ 2
Important Safety Instructions .............................................. 3
Recognize Safety Symbols, Words, and Labels ....................... 3
General Information ............................................................... 4
Features.................................................................................... 4
Achieving Less Air Leakage ....................................................... 4
Clearances And Accessibility ................................................... 4
Insulation ................................................................................ 4
Installation Instructions ........................................................ 4
Blower with Cased Evaporator Coil Installation ................... 4
Upflow Installation ................................................................ 4
Counterflow Installation ....................................................... 5
Horizontal Installation .......................................................... 5
Counterflow and Horizontal Applications ............................ 5
Electrical Connections ............................................................ 6
208/230 Volt Line Connections ................................................ 6
Low Voltage Wiring ................................................................. 6
Operation on 208 Volt Supply .................................................. 6
24 Volt “Legacy” Thermostat Wiring ....................................... 6
Auxiliary Alarm Switch .......................................................... 6
Circulator Blower ................................................................... 7
Troubleshooting ................................................................... 11
Electrostatic Discharge (ESD) Precautions ........................... 11
Diagnostic Chart ................................................................... 11
Fault Recall ............................................................................ 11
ComfortNet™ System ............................................................. 11
Airflow Consideration .......................................................... 11
Control Wiring ...................................................................... 12
ComfortNet™ System Advance Features ............................... 12
Modular Blower Advanced Features Menu ......................... 13
Diagnostics ............................................................................ 14
Network Troubleshooting .................................................... 14
System Troubleshooting ....................................................... 14
Troubleshooting Information .............................................. 15
Wiring Diagram
................................................................... 20
Homeowners Routine Maintenance Recommendations .... 21
Start Up CHecklist ............................................................... 22
THIS PRODUCT CONTAINS ELECTRONIC COMPONENTS WHICH REQUIRE A
DEFINITE GROUND. PROVISIONS ARE MADE FOR CONNECTION OF THE GROUND.
A DEDICATED GROUND FROM THE MAIN POWER SUPPLY OR AN EARTH GROUND
MUST BE PROVIDED.
Introduction
This booklet contains the installaon and operang instrucons for
your modular blower cabinet. All warnings and precauons within
this booklet must be observed. Improper installaon can result in
problems ranging from noisy operaon to property or equipment
damages, dangerous condions that could result in injury or per-
sonal property damage and that are not covered by the warranty.
Read this booklet and any instrucons packaged with accessories
prior to installaon. Give this booklet to the user and explain its
provisions. The user should retain this booklet for future reference.
NOTE: Upon start up in communicang mode the circuit board
may display an “Ec” error. This is an indicaon that the dip switches
on the control board need to be congured in accordance with the
Electric Heang Airow Table in this manual. Conguring the dip
switches and reseng power to the unit will clear the error code.
Electrostatic Discharge (ESD) Precautions
NOTE: Discharge body’s stac electricity before touching unit. An
electrostac discharge can adversely aect electrical components.
Use the following precauons during modular blower installaon
and servicing to protect the integrated control module from dam-
age. By pung the modular blower, the control, and the person
at the same electrostac potenal, these steps will help avoid
exposing the integrated control module to electrostac discharge.
This procedure is applicable to both installed and uninstalled (un-
grounded) blowers.
1. Disconnect all power to the blower. Do not touch the
integrated control module or any wire connected to the
control prior to discharging your body’s electrostac charge
to ground.
2. Firmly touch a clean, unpainted, metal surface of the
modular blower near the control. Any tools held in a
person’s hand during grounding will be discharged.
3. Service integrated control module or connecng wiring
following the discharge process in step 2. Use cauon not
to recharge your body with stac electricity; (i.e., do not
move or shue your feet, do not touch ungrounded objects,
etc.). If you come in contact with an ungrounded object,
repeat step 2 before touching control or wires.
4. Discharge your body to ground before removing a new
control from its container. Follow steps 1 through 3 if
installing the control on a blower. Return any old or new
controls to their containers before touching any ungrounded
object.
Checking Product Received
Upon receiving the unit, inspect it for damage from shipment.
Claims for damage, either shipping or concealed, should be led
immediately with the shipping company. Check the unit model
number, specicaons, electrical characteriscs and accessories
to determine if they are correct. In the event an incorrect unit is
shipped, it must be returned to the supplier and must NOT be in-
stalled. The manufacturer assumes no responsibility for installaon
of incorrectly shipped units.
Replacement Parts
Ordering Parts
When reporng shortages or damages, or ordering repair parts,
give the complete unit model and serial numbers as stamped on
the unit’s nameplate.
Replacement parts for this appliance are available through your
contractor or local distributor. For the locaon of your nearest
distributor contact:
HOMEOWNER SUPPORT
DAIKIN COMFORT TECHNOLOGIES MANUFACTURING, INC.
19001 KERMIER ROAD
WALLER, TEXAS 77484
(877) 254-4729
Contents

3
Important Safety Instructions
Recognize Safety Symbols, Words, and Labels
The following symbols and labels are used throughout this man-
ual to indicate immediate or potenal hazards. It is the owner’s
responsibility to read and comply with all safety informaon and
instrucons accompanying these symbols. Failure to heed safety
informaon increases the risk of property damage, product dam-
age, personal injury or death.
HIGH VOLTAGE!
D
ISCONNECT
ALL
POWER
BEFORE
SERVICING
.
M
ULTIPLE
POWER
SOURCES
MAY
BE
PRESENT
. F
AILURE
TO
DO
SO
MAY
CAUSE
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
WARNING
CO can cause serious illness including permanent brain
damage or death.
Advertencia especial para la instalación de calentadores ó manejadoras
de aire en áreas cerradas como estacionamientos ó cuartos de servicio.
El monóxido de carbono puede causar enfermedades severas
como daño cerebral permanente ó muerte.
Las emisiones de monóxido de carbono pueden circular a través
del aparato cuando se opera en cualquier modo.
RISQUE D'EMPOISONNEMENT AU
MONOXYDE DE CARBONE
Cette ventilation est nécessaire pour éviter le danger d'intoxication
au CO pouvant survenir si un appareil produisant du monoxyde
de carbone continue de fonctionner au sein de la zone confinée.

4
General Information
The MBVK Blower Cabinets are used in combinaon with a cased
evaporator coil. This combinaon of blower and coil funcons
as the indoor part of a split air-condioning system, and may be
matched with a remote condensing or heat pump unit. The blower
cabinet can also funcon as an electric furnace when used with
an electric heater.
NOTE: The electric heating elements for electric furnace
installaon are not shipped with the cabinet and are eld-installed.
Systems should be properly sized by heat gain and loss calculaons
made according to methods of the Air Condioning Contractors
Associaon (ACCA) or equivalent. It is the contractor’s responbility
to ensure the system has adequate capacity to heat or cool the
condioned space.
Features
This modular blower is a part of the ComfortNet™ family of prod-
ucts. It may be installed as part of a “legacy” system using a stan-
dard 24 VAC thermostat or, with a ComfortNet™ thermostat kit, as
part of a digitally communicang system. The ComfortNet™ system
simplies wiring, provides enhanced setup features and elevates
diagnoscs capabilies.
Achieving Less Air Leakage:
Ensure all the gaskets remain intact on surfaces as shipped with the
unit. Ensure upon installaon that the plasc breaker cover is ush
with the access panel and access panel is ush with the cabinet.
With these requirements sased, the unit achieves less airow
leakage when tested in accordance with ASHRE Standard 193.
• Cabinet air leakage less than 2.0% at 1.0 inch H
2
O when
tested in accordance with ASHRAE standard 193.
• Cabinet air leakage less than 1.4% at 0.5 inch H
2
O when
tested in accordance with ASHRAE standard 193.
Clearances And Accessibility
The unit can be posioned for upow, counterow, horizontal right
or horizontal le operaon. Zero clearance is allowed on all sides
for combusble materials. Thirty-six inches should be alloed on
the door side for maintenance and service.
To reduce risk of rusng, do not install the unit directly on the
ground or on a oor that is likely to be wet. In such environments,
the unit must be elevated by use of a sturdy, nonporous material.
NOTE: This unit should be installed in a manner so that it is not
accessible to the public.
Insulation
To ensure ecient operaon, review the following precauons.
• If the unit is located in an area with high ambient
temperature and/or high humidity, the air handler may
be subject to nuisance sweang of the casing. On these
installaons, a wrap of 2” berglass insulaon with a
vapor barrier is recommended.
• The factory recommends insulang the duct running
through any uncondioned spaces.
To reduce operang sound and vibraon transmission use exible
canvas duct connecons at the cabinet.
Figure 1 - Coil and Blower Connecon
Installation Instructions
NOTE: This appliance is designed for indoor installaon only at max.
altude of 10,500 feet above sea level & a min altude of -184 feet
below sea level.
Blower with Cased Evaporator Coil Installation
Secure the coil and blower together with the two connector plates
and screws supplied in the blower bag assembly. Use one connec-
tor plate and six screws on each side of the unit.
If accessory electric heat is to be added, install now per the instruc-
ons shipped with the heater kit.
Air Flow
Figure 2 - Upow Applicaon
Upflow Installation
For upow installaons, the blower cabinet must sit on top of the
coil cabinet (Figure 2).
NOTE: All panels should be in place before installing the cabinet.
1. Place the blower and coil cabinet assembly upright on the
return duct or duct opening. Ensure that there is ample
support for the cabinet assembly and all aached ductwork.
2. Connect refrigerant and condensate drain connecons
per the evaporator coil installaon instrucons. Ensure
refrigerant and drain lines do not interfere with service
access to the unit.
3. Aach supply ductwork. Seal connecons between unit and
ductwork as required to reduce/eliminate air leakage.
4. Make electrical connections as specified in Electrical
Connecons secon of this manual.

5
Counterflow Installation
For counterow installaons, the evaporator coil cabinet must sit
on top of the blower cabinet (Figure 3). NOTE: All panels should
be in place when installing the unit.
NOTE: Supply ductwork for counterow applicaons, must be Class I.
However, if combusble ductwork is used, sheet metal protecon
is required.
Air Flow
Figure 3 - Counterow Applicaon
1. Place the blower and coil cabinet assembly supply outlet
on the supply duct or duct opening. Ensure there is ample
support for the unit and all aached ductwork.
2. Connect refrigerant and condensate drain connecons
per the evaporator coil installaon instrucons. Ensure
refrigerant and drain lines do not interfere with service
access to the unit.
3. Aach return ductwork. Seal connecons between unit and
ductwork as required to reduce/eliminate air leakage.
4. Make electrical connections as specified in Electrical
Connecons secon of this manual.
Horizontal Installation
For horizontal installaons, the coil cabinet must be upstream of
the blower cabinet (Figures 4 and 5). NOTE: All panels should be
in place when installing the unit.
1. Set the unit near its nal installaon place. The unit must
be supported along the enre length of the unit. Rubber
isolaon pads may be used to reduce sound and vibraon
transmission. Ensure there is ample support for the unit
and all aached ductwork.
NOTE: Unit must be mounted with access panel facing the front
as shown in following diagrams.
2. If installed above a nished ceiling or living space, be sure
to put a secondary drain pan under the enre unit, and pipe
the drain separately from the main condensate drain.
3. Connect refrigerant and condensate drain connecons per the
coil secon installaon instrucons. Ensure refrigerant and
drain lines do not interfere with service access to the unit.
Support
Figure 4 - Ac Installaon
4. Aach return and supply ductwork. Seal connecons.
5. Make electrical connections as specified in Electrical
Connecons secon of this manual.
Support
Figure 5 - Hanging Installaon
Counterflow and Horizontal Applications
Loosen motor mount and rotate motor (See Figure 6). Be sure mo-
tor is oriented with the female connecons on the casing poinng
down. If the motor is not oriented with the connecons poinng
down, water could collect in the motor and cause premature failure.
NOTE: Aer rotang motor, ghten motor mount to secure motor.
Be sure that the gap between the motor and the insulaon is the
same as it was before loosening the motor mount. This will ensure
that the blower wheel is properly spaced inside the blower housing.
FEMALE CONNECTIONS
SIDE VIEW
WARNI NG
SOFTWARE VER.
TOP
FRONT VIEW
Figure 6 - MBVK Motor Orientaon

6
CAUTION
TO AVOID THE RISK OF PERSONAL INJURY, WIRING TO THE
UNIT MUST BE PROPERLY POLARIZED AND GROUNDED.
WARNING
All wiring must comply with applicable local and national
codes. Type and location of fused disconnect switch(es) must
comply with all applicable codes and provide overcurrent
protection as shown on the nameplate.
Operation on 208 Volt Supply
The unit transformer is factory connected for 230 V operaon. If
unit is to operate on 208 V, disconnect the red wire from terminal
3 of the unit transformer and connect them to terminal 2 of the
unit transformer.
24 Volt “Legacy” Thermostat Wiring
NOTE: Wire roung must not interfere with the circulator blower
operaon or roune maintenance.
The oponal usage of a dehumidistat allows the modular blower’s
circulator blower to operate at a slightly lower speed during a com-
bined thermostat call for cooling and dehumidistat call for dehu-
midicaon. This lower blower speed enhances dehumidicaon
of the condioned air as it passes through the AC coil. For proper
funcon, a dehumidistat applied to this modular blower must op-
erate on 24 VAC and ulize a switch which opens on humidity rise.
To install/connect a dehumidistat:
1. Turn OFF power to modular blower
2. Secure the dehumidistat neutral wire (typically the white
lead) to the screw terminal marked “DEHUM” on the
modular blower’s integrated control module.
3. Secure the dehumidistat hot wire (typically the black lead)
to the screw terminal marked “R” on the modular blower’s
integrated control module.
4. Secure the dehumidistat ground wire (typically the green
lead) to the ground screw on the modular blower. NOTE:
Ground wire may not be present on all dehumidistats.
5. Turn ON power to modular blower.
ON
OFF
Move to the
ON position
to enable
dehumidification
S5 S6 S7 S8
Figure 7 - Dip Switches
Auxiliary Alarm Switch
The control is equipped with two Auxiliary Alarm terminals labeled
CAS which can be ulized with communicang mode setups (typ-
ically used for condensate switch wiring but could be used with
compable C02 sensors or re alarms).
Legacy mode use
In a legacy system (Non-communicang), this feature is not oper-
aonal. Any auxiliary alarm switch must be used to interrupt the
Y1 signal either to the indoor or outdoor unit.
Electrical Connections
If this modular blower is matched up with a cased coil from the
CAPEA, CAPE, CHPE, or CXTQ product families, the cased coil PCB
must be supplied with 24VAC from an appropriately powered
transformer. A transformer has been included with the cased coil.
Refer to the cased coil installaon & operaon instrucon manual
regarding transformer parts and installaon. A disconnect should
be incorporated in the eld wiring in accordance with wiring codes.
Consult the local power company and local codes before install-
ing this unit. All wiring must be in accordance with the Naonal
Electrical Code as well as all local codes. Knockouts have been
provided on side and top of the cabinet for the installaon of the
electrical conduit. If the knockouts on the cabinet sides are used
for electrical conduit, an adapter ring must be used in order to
meet UL60335-2-40 safety requirements. Use Minimum Circuit
Ampacity and type of wire to determine proper wire size. The unit
MUST be properly grounded. A ground lug is provided in the unit.
Check all factory connecons before connecng electrical power
to unit to ensure none were loosened or disconnected during
shipping and handling.
208/230 Volt Line Connections
If heater kits will not be installed, remove the proper size knockout
for the electrical conduit connecon. Connect electrical conduit to
the unit using two washers to make an approved connecon. If the
high voltage knockout is removed, please use the provided foam
tape to seal the opening with the conduit.
The power supply wires must be connected to the red and black
power wiring. Two wire nuts are provided in the bag assembly for
this connecon. Wrap the wire nuts with electrical tape. (Insulat-
ed crimp type connectors, eld supplied, may be substuted for
the wire nuts and electrical tape provided proper size connectors
are used.) A ground wire MUST be connected to the ground lug
inside the unit.
Low Voltage Wiring
A 24V-control voltage connects the air handler to the room thermo-
stat and condenser and must use low voltage wiring with copper
conductors. A minimum 18 AWG wire must be used for installaons
up to 150 feet. Low voltage wiring must be connected through the
top of the cabinet or either side. See the “Thermostat Wiring” sec-
on of this manual for typical low voltage wiring connecons. If the
low voltage opening is being used, please replace the pre-installed
cap with the bushing provided in the literature kit.
WARNING
HIGH VOLTAGE
To prevent personal injury or death due to
electrical shock, disconnect the electrical
power before electrically connecting the unit.
WARNING
To avoid the risk of fire or equipment damage, use copper
conductors.

7
Communicaon mode use
This feature can be acvated or deacvated through the thermostat
user menus. An auxiliary alarm switch must be normally closed
and open when the base pan’s water level in the evaporator coil
reaches a parcular level. The control will respond by turning o
the outdoor compressor and display the proper fault codes. If the
switch is detected closed for 30 seconds, normal operaon resumes
and the error message will be removed.
CAS
SWITCH
Figure 8 - Auxiliary Alarm Switch
Air Handler Integrated
Control Module
Typical Single-Stage Cool,
Single-Stage Heat Thermostat
Dehumidistat
[Optional]
Remote Condensing Unit
(Single-Stage AC)
NEU
HOT
1 2 R C G
W1 Y1 Y2
O
DEHUM
R C G
W1 Y1
R C
Y
Place Jumper Between Y1
and O for Proper
Dehumidification Operation
and Proper Ramping
Profile Operation
W2
Figure 9 - Typical Single-Stage Cooling
with Single-Stage Heang
Air Handler Integrated
Control Module
Typical Two-Stage Cool,
Two-Stage Heat Thermostat
Dehumidistat
[Optional]
Remote Condensing Unit
(Two-Stage AC)
NEU
HOT
1 2 R C G
W1 W2 Y1 Y2
O
DEH UM
R C G
W1 W2 Y1 Y2
R C
Y1 Y2
Place Jumper Between Y1
and O for Proper
Dehumidification Operation
and Proper Ramping
Profile Operation
Figure 10 - Typical Two-Stage Cooling
with Two-Stage Heang
1 2 R C
A
ir Handler
Integrated Control Module
Typical Single-Stage Cool,
Single-Stage Heat
Heat Pump Thermostat
Dehumidistat
[Optional]
G
W1 W2 Y1 Y2
O
DEH UM
Remote Condensing Unit
(Single-Stage HP)
NEU
HOT
W/E
R C G
Y1
O
R C
W1 Y
O
Figure 11 - Typical Single-Stage Heat Pump
with Auxilary/Emergency Heang
1 2 R C
A
ir Handler
Integrated Control Module
Typical Two-Stage Cool,
Two-Stage Heat
Heat Pump Thermostat
Dehumidistat
[Optional]
G
W1 W2 Y1 Y2
O
DEH UM
Remote Condensing Unit
(Two-Stage HP)
NEU
HOT
W/E
R C G
W2 Y1 Y2
O
R C
W1 Y1 Y2
O
Figure 12 - Typical Two-Stage Heat Pump Heang
and Auxilary/Emergency Heang
Circulator Blower
This modular blower is equipped with a variable speed circulator
blower. This blower provides ease in adjusng blower speeds. The
Specicaon Sheet applicable to your model provides an air-ow
table, showing the relaonship between airow (CFM) and exter-
nal stac pressure (E.S.P.), for the proper selecon of heang and
cooling speeds. The heang blower speed is shipped set at “21
kW”, and the cooling blower speed is set at “D”. These blower
speeds should be adjusted by the installer to match the installaon
requirements so as to provide the correct electric heang CFM and
correct cooling CFM.
Use the CFM LED (green) to obtain an approximate airow quan-
ty. The green CFM LED blinks once for each 100 CFM of airow.
1. Determine the tonnage of the cooling system installed with
the modular blower. If the cooling capacity is in BTU/hr
divide it by 12,000 to convert capacity to TONs.
Example: Cooling Capacity of 30,000 BTU/hr.
30,000/12,000 = 2.5 Tons
2. Determine the proper air ow for the cooling system. Most
cooling systems are designed to work with air ows between
350 and 450 CFM per ton. Most manufacturers recommend
an air ow of about 400 CFM per ton.
Example: 2.5 tons X 400 CFM per ton = 1000 CFM

8
1
2
1
2
1
2
1
2
OFF OFF OFF OFFON ON ON ON
Tap A Tap B
Cooling Air flow Speed Tap (*indicates factory setting)
Tap C Tap D*
3
4
+5%* -5%
A
ir flow Adjust Taps (*indicates factory setting)
+10% -10%
OFF OFF OFF OFFON ON ON ON
3
4
3
4
3
4
3
4
-5%
A
ir flow Adjust Taps (*indicates factory setting)
+10%
OFF OFF OFF OFFON ON ON ON
3
4
3
4
3
4
12
13
12
13
12
13
12
13
OFF
OFF
OFF
OFFON
ON
ON ON
25% 50%*
Fan Only Selection (*indicates factory setting)
75% 100%
12
13
12
13
12
13
12
13
OFF
OFF
OFF
OFFON
ON
ON ON
Fan Only Selection (*indicates factory setting)
Figure 13 - Airow and Fan Selecon
The cooling system manufacturer’s instrucons must be checked
for required air ow. Any electronic air cleaners or other devices
may require a specic airow; consult installaon instrucons of
those devices for requirements.
3. Knowing the modular blower model, locate the high stage
cooling air ow charts in the Specicaon Sheet applicable to
your model. Look up the cooling air ow determined in step 2
and nd the required cooling speed and adjustment seng.
Example: A MBVK12BP1X00 modular blower installed with
a 2.5 ton air condioning system. The air ow needed
is 1000 CFM. Looking at the cooling speed chart for
MBVK12BP1X00, nd the air ow closest to 1000 CFM. A
cooling airow of 1000 CFM can be aained by seng the
cooling speed to “C” and the adjustment to “Normal” (no
adjustment).
4. Locate the blower speed selecon DIP switches on the
integrated control module. Select the desired “cooling”
speed tap by posioning switches 1 and 2 appropriately.
If airow adjustment is required, set dip switch S8 (trim
enable) to ON (trim enable default is o). Then select
the desired “adjust” tap by posioning switches S3 and
S4 appropriately. Refer to the following gure for switch
posions and their corresponding taps. Verify CFM by
counng the number of mes the green CFM LED blinks.
5. Continuous fan speeds that provide 25, 50, 75, and
100%of the furnace’s maximum airflow capability
are selectable via dip switches S12 and S13.
If the furnace’s maximum airow capability is 2000 CFM
and 25% connuous fan speed is selected, the connuous
fan speed will be 0.25 x 2000 CFM = 500 CFM.
6. The mul-speed circulator blower also oers several custom
ON/OFF ramping proles. These proles may be used to
enhance cooling performance and increase comfort level.
The ramping proles are selected using DIP switches 5
and 6. Refer to Figure 14 for switch posions and their
corresponding taps. Refer to the bullet points below for a
descripon of each ramping prole. Verify prole selecon
by counng the green CFM LED blinks and ming each step
of the ramping prole.
5
6
5
6
5
6
5
6
OFF OFF OFF OFFON ON ON ON
Tap A Tap B Tap C Tap D*
Figure 14 - Switch Posions and Taps
• Prole A provides only an OFF delay of one (1) minute at
100% of the cooling demand airow.
Figure 15 - Prole A
• Prole B ramps up to full cooling demand airow by rst
stepping up to 50% of the full demand for 30 seconds.
The motor then ramps to 100% of the required airow.
A one (1) minute OFF delay at 100% of the cooling
Figure 16 - Prole B
• Prole C ramps up to 82% of the full cooling demand airow
and operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airow. Prole C
also has a one (1) minute 100% OFF delay.
Figure 17 - Prole C
• Prole D ramps up to 50% of the demand for 1/2 minute,
then ramps to 82% of the full cooling demand airow
and operates there for approximately 7 1/2 minutes. The
motor then steps up to the full demand airow. Prole D
has a 1/ 2 minute at 50% airow OFF delay.

9
Figure 18 - Prole D
7. If an electric heater kit has been installed, determine the
heater kilowa (kW) rang. Find the heater size in the
table below. Set dipswitches 9, 10, and 11 for the installed
heater as shown in the table below. The adjust seng
(already established by the cooling speed selecon) also
applies to the electric heater kit airow. Thus, the electric
heater airow is adjusted by the same amount. Verify
selected CFM by counting the green CFM LED blinks.
If an electric heater kit has not been installed, set dip
switches 9, 10, and 11 to any valid heater kit seng (see
airow table for valid sengs). This will prevent an Ec Error
code from being displayed.

10
C ------- 7.5 min/82% 60 sec/100%
Profiles Pre-Run Short-Run OFF Delay
B ------- 30 sec/50% 60 sec/100%
Speed Selection Dip Switches
0140A00068-A
D 30 sec/50% 7.5 min/82% 30 sec/50%
A ------- -------- 60 sec/100%
To Set Airflow: (1) Select model and desired High Stage Cooling Airflow.
Determine the corresponding tap (A,B,C,D). Set dip switches S1 and S2 to
the appropriate ON / OFF positions. (2) Select model and installed electric
heater size. Set dip switches S9, S10, and S11 to the appropriate ON / OFF
positions. (3) If airflow adjustment is required set T
rim Enable Switch S8 to
ON (OFF = 0% Trim) and set S3 and S4
to appropriate ON / OFF positions.
Tap A is +5%, Tap B is -5%, Tap C is +10%, Tap D is -10%.
To Set Comfort Mode: Select desired Comfort Mode Profile (see profiles
above). Set dip switches S5 and S6 to appropriate ON / OFF positions.
Dehumidification: To enable, set dip switch S7 to ON. Cooling airflow will
be reduced to 85% of nominal value during
cool call when Dehum
command is present. To disable, set S7 to OFF.
Continuous Fan Speed: Use dip switches S12 and S13 to select one of 4
continuous fan speeds, Tap A is 25%. Tap B is 50%, Tap C is 75%, Tap D
is 100%.
A 800 1200
B 1070 1600
C 1200 1800
D 1340 2000
A 670 1000
B 800 1200
C 940 1400
D 1070 1600
A 400 600
B 540 800
C 670 1000
D 800 1200
Model
Low Stage
Cool
Tap
High Stage
Cool
Cool
Sele
ction
Switches
Adjust
Selection
Switches
Profile
Selection
Switches
Continuous
Fan
Speed
MBVC1200*
MBVC1600*
MBVC2000*
9
10
OFF OFF OFF OFFON ON ON ON
21 kW* 20 kW
Electric Heating Air Flow (*indicates factory setting)
15 kW 10 kW
OFF OFF OFF OFFON ON ON ON
8 kW 6 kW 5 kW 3 kW
11
9
10
11
9
10
11
9
10
11
9
10
11
9
10
11
9
10
11
9
10
11
Figure 19 - Dip Switches
NOTE: Upon start up in communicang mode the
circuit board may display an “Ec” error. This is an
indicaon that the dip switches on the control board
need to be congured in accordance with the Electric
Heang Airow Table on page 7 of this manual. Con-
guring the dip switches and reseng power to the
unit will clear the error code.
20 OFF OFF ON NR NR 2000
15 OFF ON OFF 1400 1500 1500
10 OFF ON ON 1000 1000 1200
8 ON OFF OFF 740 1000 1000
6 ON OFF ON 635 800 800
5 ON ON OFF 600 800 800
3 ON ON ON 600 800 800
A 800 1200
B 1070 1600
C 1200 1800
D 1340 2000
MBVK20DP1X00
A 670 1000
B 800 1200
C 940 1400
D 1070 1600
MBVK16CP1X00
A 400 600
B 540 800
C 670 1000
D 800 1200
MBVK12BP1X00
Model
C ------- 7.5 min/82% 60 sec/100%
Profiles Pre-Run Short-Run OFF Delay
B ------- 30 sec/50% 60 sec/100%
Speed Selection Dip Switches
0140A01296-A
A OFF OFF OFF OFF OFF OFF
D 30 sec/50% 7.5 min/82% 30 sec/50%
TAP S1 S2 S3 S4 S5 S6
B ON OFF ON OFF ON OFF
A ------- -------- 60 sec/100%
To Set Airflow: (1) Select model and desired High Stage Cooling Airflow.
Determine the corresponding tap (A,B,C,D). Set dip switches S1 and S2 to
the appropriate ON / OFF positions. (2) Select model and installed electric
heater size. Set dip switches S9, S10, and S11 to the appropriate ON / OFF
positions. (3) If airflow adjustment is required set Trim Enable Switch S8 to
ON (OFF = 0% Trim) and set S3 and S4 to appropriate ON / OFF positions.
Tap A is +5%, Tap B is -5%, Tap C is +10%, Tap D is -10%.
To Set Comfort Mode: Select desired Comfort Mode Profile (see profiles
above). Set dip switches S5 and S6 to appropriate ON / OFF positions.
Dehumidification: To enable, set dip switch S7 to ON. Cooling airflow will
be reduced to 85% of nominal value during cool call when Dehum
command is present. To disable, set S7 to OFF.
Continuous Fan Speed: Use dip switches S12 and S13 to select one of 4
continuous fan speeds, Tap A is 25%. Tap B is 50%, Tap C is 75%, Tap D
is 100%.
C OFF ON OFF ON OFF ON
D ON ON ON ON ON ON
Cool Adjust Profile
Selection Selection Selection
Switches Switches Switches
Low Stage
Cool
Tap
High Stage
Cool
Continuous
Fan
Speed
S12
S13
OFF
ON
ON
ON
ONOFF
OFF
OFF
Htr Kw
S9
S10
S11
MBVK12BP1X00
MBVK16CP1X00
MBVK20DP1X00
0140A01296

11
Troubleshooting
Electrostatic Discharge (ESD) Precautions
NOTE: Discharge body’s stac electricity before touching unit. An
electrostac discharge can adversely aect electrical components.
Use the following precauons during modular blower installaon
and servicing to protect the integrated control module from dam-
age. By pung the modular blower, the control, and the person
at the same electrostac potenal, these steps will help avoid
exposing the integrated control module to electrostac discharge.
This procedure is applicable to both installed and uninstalled (un-
grounded) blowers.
1. Disconnect all power to the blower. Do not touch the
integrated control module or any wire connected to the
control prior to discharging your body’s electrostac charge
to ground.
2. Firmly touch a clean, unpainted, metal surface of the
modular blower near the control. Any tools held in a
person’s hand during grounding will be discharged.
3. Service integrated control module or connecng wiring
following the discharge process in step 2. Use cauon not
to recharge your body with stac electricity; (i.e., do not
move or shue your feet, do not touch ungrounded objects,
etc.). If you come in contact with an ungrounded object,
repeat step 2 before touching control or wires.
4. Discharge your body to ground before removing a new
control from its container. Follow steps 1 through 3 if
installing the control on a blower. Return any old or new
controls to their containers before touching any ungrounded
object.
Diagnostic Chart
Refer to the Troubleshoong Chart at the end of this manual for
assistance in determining the source of unit operaonal problems.
The 7 segment LED display will provide any acve fault codes. An
arrow printed next to the display indicates proper orientaon (ar-
row points to top of display). See following image.
WARNING
HIGH VOLTAGE
To prevent personal injury or death due to
electrical shock, disconnect the electrical
power before performing any service or
maintinance
7 Segment
Diagnostic
Display
Figure 20 - Diagnosc Display
Fault Recall
The integrated control module is equipped with a momentary pushbuon
switch that can be used to display the last six faults on the 7 segment LED
display. The control must be in Standby Mode (no thermostat inputs) to
use the feature. Depress the push-buon for approximately two seconds
and less than ve seconds. The LED display will then display the six most
recent faults beginning with the most recent fault and decremenng to
the least recent fault. The faults may be cleared by depressing the buon
for greater than ve seconds.
NOTE: Consecuvely repeated faults are displayed a maximum of three
mes.
ComfortNet ™ System
Overview
The ComfortNet™ system (or CT™ system) is a system that includes
a ComfortNet™ compable modular blower and air condioner
or heat pump with a Daikin Communicang thermostat. Any
other system conguraons are considered invalid ComfortNet™
systems and must be connected as a tradional (or legacy) system
(see Electrical Connecons - 24 Volt Thermostat Wiring for wiring
connecons).
A ComfortNet™ heating/air conditioning system differs from
a legacy/tradional system in the manner in which the indoor
unit, outdoor unit and thermostat interact with one another.
In a traditional system, the thermostat sends commands to
the indoor and outdoor units via analog 24 VAC signals. It is a
one-way communicaon path in that the indoor and outdoor
units typically do not return information to the thermostat.
In a ComfortNetTM system, the indoor unit, outdoor unit, and
thermostat “communicate” digitally with one another creang a
two-way communicaons path. The thermostat sends commands
to the indoor and outdoor units, and also requests and receives
informaon from both the indoor and outdoor units.
Two-way digital communicaons is accomplished using only two
wires. The thermostat and subsystem controls are powered with
24 VAC Thus, a maximum of 4 wires between the equipment and
thermostat is all that is required to operate the system.
Airflow Consideration
Airow demands are managed dierently in a fully communicang
system than they are in a legacy wired system. The system oper-
ang mode (as determined by the thermostat) determines which
unit calculates the system airow demand. If the indoor unit is
responsible for determining the airow demand, it calculates the
demand and sends it to the ECM motor. If the outdoor unit or
thermostat is responsible for determining the demand, it calculates
the demand and transmits the demand along with a fan request
to the indoor unit. The indoor unit then sends the demand to the
ECM motor. Figure 21 lists the various ComfortNet™ systems, the
operang mode, and airow demand source.

12
System
System Operating
Mode
Airflow Demand Source
Cooling Air Conditioner
Heating Air Handler
Continuous Fan Thermostat
Cooling Heat Pump
Heat Pump Heating
Only
Heat Pump
HP + Electric Heat
Strips
> of Heat Pump or Air
Handler Demand
Electric Heat Strips
Only
Air Handler
Continuous Fan Thermostat
Air Conditioner +
Air Handler
Heat Pump + Air
Handler
Figure 21 - Airow Demands
For example, assume the system is a heat pump matched with
an air handler. With a call for low stage cooling, the heat pump
will calculate the system’s low stage cooling airow demand. The
heat pump will then send a fan request along with the low stage
cooling airow demand to the air handler. Once received, the
air handler will send the low stage cooling airow demand to the
ECM motor. The ECM motor then delivers the low stage cooling
airow. See the applicable ComfortNet™ air condioner or heat
pump installaon manual for the airow delivered during cooling
or heat pump heang.
In connuous fan mode, the Daikin Communicang thermostat
provides the airow demand. The thermostat may be cong-
ured for a low, medium, or high connuous fan speed. The low,
medium, and high fan speeds correspond to 25%, 50%, and 75%,
respecvely, of the air handlers’ maximum airow capability.
During connuous fan operaon, the thermostat sends a fan
request along with the connuous fan demand to the air handler.
The air handler, in turn, sends the demand to the ECM motor.
The ECM motor delivers the requested connuous fan airow.
medium, or high connuous fan speed. The low, medium, and
high fan speeds correspond to 25%, 50%, and 75%, respecvely, of
the air handlers’ maximum airow capability. During connuous
fan operaon, the thermostat sends a fan request along with the
connuous fan demand to the air handler. The air handler, in turn,
sends the demand to the ECM motor. The ECM motor delivers the
requested connuous fan airow.
Control Wiring
NOTE: Refer to secon Electrical Connecons for 208/230 volt line
connecons to the modular blower.
NOTE: A removable plug connector is provided with the control
to make thermostat wire connecons. This plug may be removed,
wire connecons made to the plug, and replaced. It is STRONGLY
recommended that you do no connect mulple wires into a single
terminal. Wire nuts are recommended to ensure one wire is used
for each terminal.
Typical 18 AWG thermostat wire may be used to wire the system
components. 150 feet is the maximum recommended length of
wire recommended between indoor and outdoor unit, or between
indoor unit and thermostat.
Only data lines 1 and 2 are required between the indoor and out-
door units. The included 40VA, 208/230 VAC to 24 VAC transformer
must be installed in the outdoor unit to provide 24 VAC power
to the outdoor unit’s electronic control. See kit instrucons for
mounng and wiring instrucons.
1
2
R
C
1
2
R
C
1
2
R
C
CTK04
Figure 22 - System Wiring
ComfortNET™ System Advance Features
The ComfortNet™ system permits access to addional system
informaon, advanced setup features, and advanced diagnos-
c/troubleshoong features. These advanced features are
organized into a menu structure. See the following MODULAR
BLOWER ADVANCED FEATURES MENUS secon for layout of
menu shortcuts.

13
MODULAR BLOWER ADVANCED FEATURES MENU
12
Submenu Item Indication/User Modifiable Options Comments
ylno yalpsid roFtluaf tnecer tsoM)1# TLUAF( 1 tluaF
Fault 2 (FAULT #2) Next most recent fault For display only
Fault 3 (FAULT #3) Next most recent fault For display only
Fault 4 (FAULT #4) Next most recent fault For display only
Fault 5 (FAULT #5) Next most recent fault For display only
Fault 6 (FAULT #6) Least recent fault For display only
tluaf eht sraelc ”SEY“ gnitceleSSEY ro ON)RAELC( yrots
iH tluaF raelC
history
NOTE:
Consecutively repeated faults are shown a maximum of 3 times
DIAGNOSTICS
Submenu Item Indication (for Display Only; not User Modifiable)
Model Number (MOD NUM) Displays the modular blower model number
Serial Number (SER NUM) Displays the modular blower serial number (Optional)
Software (SOFTWARE) Displays the application software revision
IDENTIFICATION
stnemmoCsnoitpO elbaifidoM resUmetI unembuS
Heat Airflow Trim (HT
TRM)
-10% to +10% in 2% increments,
default is 0%
Trims the heating airflow by the selected
amount.
tupni mralA yrailixuA elbasid ro elbanEFFO / NOmralA yrailixuA
SET-UP
Submenu Item Indication (for Display Only; not User Modifiable)
edom gnitarepo rewolb raludom tnerruc eht syalpsiD)EDOM( edoM
edom gnitarepo tnerruc eht rof wolfria eht syalpsiD)MFC( MFC
STATUS

14
Diagnostics
Accessing the modular blower’s diagnoscs menu provides ready
access to the last six faults detected by the modular blower. Faults
are stored most recent to least recent. Any consecuvely repeat-
ed fault is stored a maximum of three mes. Example: A clogged
return air lter causes the modular blower’s motor to repeatedly
enter a liming condion. The control will only store this fault the
rst three consecuve mes the fault occurs.
NOTE: It is highly recommended that the fault history be cleared
when performing maintenance or servicing the modular blower.
Network Troubleshooting
The ComfortNet™ system is a fully communicang system, and
thus, constutes a network. Occasionally the need to troubleshoot
the network may arise. The integrated control has some on-board
tools that may be used to troubleshoot the network.
These tools are: red communicaons LED, green receive (Rx) LED,
and LEARN buon.
• Red communicaons LED – Indicates the status of the
network. The table below indicates the LED status and
the corresponding potenal problem.
• Green receive LED – Indicates network trac. The table
below indicates the LED status and the corresponding
potenal problem.
• Learn buon – Used to reset the network. Depress the
buon for approximately 2 seconds to reset the network.
System Troubleshooting
NOTE: Refer to the instrucons accompanying the CT™ compable
outdoor AC/HP unit for troubleshoong informaon.
Refer to the Troubleshoong Chart in the Appendix for a lisng of
possible modular blower error codes, possible causes and correc-
ve acons.
Communciations Status LED’s
LED LED Status Indication Possible Causes Corrective Action(s) Notes & Cautions
Off
Normal condition None None None
1 Flash
Communications
Failure
Communications Failure Depress Learn Button
Verify that bus BIAS
and TERM dipswitches
are in the ON position.
Depress once quickly
for a power-up reset
Depress and hold for 2
seconds for an out-of-
box reset
Red
Communications
LED
2 Flashes
Out-of-box reset Control power up
Learn button depressed
None None
Off
No power
Communications error
No power to modular
blower
Open fuse
Communications error
Check fuses and circuit
breakers; replace/reset
Replace blown fuse
Check for shorts in low
voltage wiring in
modular blower/system
Reset network by
depressing learn button
Check data 1/ data 2
voltages
Turn power OFF prior
to repair.
See Network
Troubleshooting
section.
1 Steady
Flash
No network found Broken/ disconnected
data wire(s)
Modular blower is
installed as a legacy/
traditional system
Check communications
wiring (data 1/ data 2
wires)
Check wire connections
at terminal block
Verify modular blower
installation type
(legacy/ traditional or
communicating)
Check data 1/ data 2
voltages
Turn power OFF prior
to repair
Verify wires at
terminal blocks are
securely twisted
together prior to
inserting into terminal
block
See Network
Troubleshooting
section
Rapid
Flashing
Normal network
traffic
Control is “talking” on
network as expected
None None
Green Receive
LED
On Solid
Data 1/ Data 2 miss-
wire
Data 1 and data 2 wires
reversed at modular
blower, thermostat, or
CT™ compatible
outdoor AC/HP
Short between data 1
and data 2 wires
Short between data 1 or
data 2 wires and R
(24VAC) or C (24VAC
common)
Check communications
wiring (data 1/ data 2
wires)
Check wire connections
at terminal block
Check data 1/ data 2
voltages
Turn power OFF prior
to repair
Verify wires at
terminal blocks are
securely twisted
together prior to
inserting into terminal
block
See Network
Troubleshooting
section
Communications Status LED’s

15
TROUBLESHOOTING INFORMATION: AIR HANDLER DIAGNOSTIC CODES
ComfortNet™
Thermostat Only
Symptoms of Abnormal Operation
(Legacy & ComfortNet™ Thermostat)
7-Segment LED
Codes
Fault Description
Message Code
Possible Causes
Corrective Actions
Notes & Cautions
LED display is ON continuously
ON
Normal operation
None None
Normal operation None Normal operation
Electric heaters fail to energize on a
call for W1 or Auxiliary/Emergency
heat
Integrated control module LED display
provides the indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated
ComfortNet™ thermostat scrolls
“Check Air Handler” message
EC
Heater kit selected via
dipswitches is too
large for heater kits
specified in shared
data set
HTR TOO
LARGE
EC
Heater kit selected via
dipswitches is too large for
heater kits in shared data set
Verify electric heat dipswitch
settings
Verify the installed electric
heater is valid for the modular
blower. Check nameplate or
Specification Sheet applicable
to your model* for allowable
heater kit(s).
Verify shared data set is
correct for the specific model.
Re-populate data using
BTSDL01 if required.
Turn power OFF prior to
repair.
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Turn power off before
removing BTSDL01.
Electric heat airflow is higher than
expected on a call for W1 or
Auxiliary/Emergency heat
Integrated control module LED display
provides the indicated error code.
EC
Heater kit selected via
dipswitches is too
small for heater kits
specified in shared
data set
HTR TOO
SMALL
EC
Heater kit selected via
dipswitches is too small for
heater kits in shared data set
Verify electric heat dipswitch
settings
Verify the installed electric
heater is valid for the modular
blower. Check nameplate or
Specification Sheet applicable
to your model* for allowable
heater kit(s).
Verify shared data set is
correct for the specific model.
Re-populate data using
BTSDL01 if required.
Turn power OFF prior to
repair.
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Turn power off before
removing BTSDL01.
Electric heat airflow is higher than
expected on a call for W1 or
Auxiliary/Emergency heat
Integrated control module LED display
provides the indicated error code.
EC
Heater kit selected via
dipswitches does not
heater kits specified in
shared data set
NO HTR
MATCH
EC
Heater kit selected via
dipswitches is doesn’t match
heater kits in shared data set
Verify electric heat dipswitch
settings
Verify the installed electric
heater is valid for the modular
blower. Check nameplate or
Specification Sheet applicable
to your model* for allowable
heater kit(s).
Verify shared data set is
correct for the specific model.
Re-populate data using
BTSDL01 if required.
Turn power OFF prior to
repair.
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Turn power off before
removing BTSDL01.
Integrated control module LED display
EF error code.
ComfortNet™ thermostat “Call for
Service”.
EF
Aux switch open
Aux Alarm
Fault
EF
High water level in the
evaporation coil.
Check overflow pan and
service
Turn power OFF prior to
service.

16
TROUBLESHOOTING INFORMATION: AIR HANDLER DIAGNOSTIC CODES
ComfortNet™
Thermostat Only
Symptoms of Abnormal Operation
(Legacy & ComfortNet™ Thermostat)
7-Segment LED
Codes
Fault Description
Message Code
Possible Causes Corrective Actions Notes & Cautions
Modular blower fails to operate
Integrated control module LED display
provides no signal.
ComfortNet™ thermostat “Call for
Service” icon illuminated
ComfortNet™ thermostat scrolls
“Check Air Handler” message
No 208/230 volt power
to modular blower or
no 24 volt power to
integrated control
module
Blown fuse or circuit
breaker
Integrated control
module has an internal
fault.
INTERNAL
FAULT
EE
Manual disconnect switch OFF
or 24 volt wire improperly
connected or loose
Blown fuse or circuit breaker
Integrated control module has
an internal fault
Assure 208/230 volt and 24
volt power to modular blower
and integrated control
module.
Check integrated control
module fuse (3A). Replace if
necessary.
Check for possible shorts in
208/230 volt and 24 volt
circuits. Repair as necessary.
Replace bad integrated
control module.
Turn power OFF prior to
repair.
Replace integrated
control module fuse with
3A automotive fuse.
Replace integrated
control module with
correct replacement part
Read precautions in
“Electrostatic Discharge”
section of manual.
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
d0
Data not yet on
network.
NO NET
DATA
d0
Modular blower does not
contain any shared data.
Populate shared data set
using BTSDL01.
Turn power OFF prior to
repair
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Error code will be
cleared once data is
loaded.
Turn power off before
removing BTSDL01
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
d1
Invalid data on
network.
INVALID
DATA
d1
Modular blower does not
contain an appropriate shared
data set.
Populate correct shared data
set using BTSDL01.
Turn power OFF prior to
repair
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Error code will be
cleared once data is
loaded.
Operation different than expected or no
operation.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
d4
Invalid shared data.
INVALID
SHARED
DATA
d4
Shared data set on BTSDL01
has been rejected by
integrated control module
Verify shared data set is
correct for the specific model.
Re-populate data using
BTSDL01 if required.
Turn power OFF prior to
repair
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Error code will be
cleared once data is
loaded.
Turn power off before
removing BTSDL01

17
TROUBLESHOOTING INFORMATION: AIR HANDLER DIAGNOSTIC CODES
ComfortNet™
Thermostat Only
Symptoms of Abnormal Operation
(Legacy & ComfortNet™ Thermostat)
7-Segment LED
Codes
Fault Description
Message Code
Possible Causes
Corrective Actions
Notes & Cautions
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b0
Circulator blower
motor is not running
when it should be
running.
MOTOR
NOT RUN
b0
Loose wiring connection at
circulator motor power leads
or circulator motor power
leads disconnected.
Failed circulator blower motor.
Tighten or correct wiring
connection.
Check circulator blower
motor. Replace if necessary.
Turn power OFF prior to
repair
Replace circulator motor
with correct
replacement part.
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b1
Integrated control
module has lost
communications with
circulator blower
motor.
MOTOR
COMM
b1
Loose wiring connection at
circulator motor control leads.
Failed circulator blower motor.
Failed integrated control
module.
Tighten or correct wiring
connection.
Check circulator blower
motor. Replace if necessary.
Check integrated control
module. Replace if
necessary.
Turn power OFF prior to
repair
Replace circulator motor
with correct
replacement part.
Replace integrated
control module with
correct replacement
part.
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b2
Circulator blower
motor horse power in
shared data set does
not match circulator
blower motor horse
power.
MOTOR
MISMATCH
b2
Incorrect circulator blower
motor in modular blower.
Incorrect shared data set in
integrated control module.
Verify circulator blower motor
horse power is the same
specified for the specific
modular blower model.
Replace is necessary.
Verify shared data set is
correct for the specific model.
Re-populate data using
correct shared data if
required.
Turn power OFF prior to
repair
Replace motor with
correct replacement
part.
Use shared data for
the specific model
Insert BTSDL01
BEFORE turning power
ON. BTSDL01 may
be removed after data is
loaded.
Error code will be
cleared once shared
data and motor horse
power match.
Turn power off before
removing BTSDL01
Modular blower operates at reduced
performance.
Airflow delivered is less than expected.
Integrated control module LED display
provides b3 error code.
b3
Circulator blower
motor is operating in a
power, temperature, or
speed limiting
condition.
MOTOR
LIMITS
b3
Blocked filters.
Restrictive ductwork.
Undersized ductwork.
High ambient temperatures.
Check filters for blockage.
Clean filters or remove
obstruction.
Check ductwork for blockage.
Remove obstruction. Verify
all registers are fully open.
Verify ductwork is
appropriately sized for
system. Resize/replace
ductwork if necessary.
See "Installation Instructions"
for installation requirements.
Turn power OFF prior to
repair.
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b4
Circulator blower
motor senses a loss of
rotor control.
Circulator blower
motor senses high
current.
MOTOR
TRIPS
b4
Abnormal motor loading,
sudden change in speed or
torque, sudden blockage of
modular blower/coil air inlet or
outlet.
High loading conditions,
blocked filters, very restrictive
ductwork, blockage of modular
blower/coil air inlet or outlet.
Check filters, filter
grills/registers, duct system,
and modular blower/coil air
inlet/outlet for blockages.
Turn power OFF prior to
repair.

18
TROUBLESHOOTING INFORMATION: AIR HANDLER DIAGNOSTIC CODES
ComfortNet™
Thermostat Only
Symptoms of Abnormal Operation
(Legacy & ComfortNet™ Thermostat)
7-Segment LED
Codes
Fault Description
Message Code
Possible Causes
Corrective Actions
Notes & Cautions
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b5
Circulator blower
motor fails to start 10
consecutive times.
MTR
LCKD
ROTOR
b5
Obstruction in circulator
blower housing.
Seized circulator blower motor
bearings.
Failed circulator blower motor.
Check circulator blower for
obstructions. Remove and
repair/replace wheel/motor if
necessary.
Check circulator blower motor
shaft rotation and motor.
Replace motor if necessary.
Turn power OFF prior to
repair
Replace motor with
correct replacement
part.
Replace wheel with
correct replacement
part.
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b6
Circulator blower
motor shuts down for
over or under voltage
condition.
Circulator blower
motor shuts down due
to over temperature
condition on power
module.
MOTOR
VOLTS
b6
High AC line voltage to
modular blower.
Low AC line voltage to
modular blower.
High ambient temperatures.
Check power to modular
blower. Verify line voltage to
blower is within the range
specified on the modular
blower rating plate.
See "Installation Instructions"
for installation requirements.
Turn power OFF prior to
repair.
Modular blower fails to operate.
Integrated control module LED display
provides indicated error code.
ComfortNet™ thermostat “Call for
Service” icon illuminated.
ComfortNet™ thermostat scrolls
“Check Air Handler” message.
b7
Circulator blower
motor does not have
enough information to
operate properly.
Motor fails to start 40
consecutive times.
MOTOR
PARAMS
b7
Error with integrated control
module.
Motor has a locked rotor
condition.
Check integrated control
module. Verify control is
populated with correct shared
data set. See data errors
above for details.
Check for locked rotor
condition (see error code
above for details).
Turn power OFF prior to
repair.
Replace with correct
replacement part(s).
Use shared data for
the specific model.
Insert BTSDL01
BEFORE turning power
ON.
BTSDL01 may be
removed after data is
loaded
Turn power off before
removing BTSDL01.
Modular blower operates at reduced
performance or operates on low stage
when high stage is expected.
Integrated control module LED display
provides indicated error code.
b9
Airflow is lower than
demanded.
LOW ID
AIRFLOW
b9
Blocked filters.
Restrictive ductwork.
Undersized ductwork.
Check filters for blockage.
Clean filters or remove
obstruction.
Check ductwork for blockage.
Remove obstruction. Verify
all registers are fully open.
Verify ductwork is
appropriately sized for
system. Resize/replace
ductwork if necessary.
Turn power OFF prior to
repair.

19
TROUBLESHOOTING INFORMATION: AIR HANDLER DIAGNOSTIC CODES
0140A00070-A
7 SEGMENT LED
(characters will alternate)
DES CRIPTION OF CONDITION
(no display) INTERNAL CONTROL FAULT / NO POWER
On STANDBY, WAITING FOR INPUTS
Ec HEATER KIT TOO LARGE, TOO SMALL, OR NO MATCH
E5 FUSE OPEN
EF AUXILIARY SWITCH OPEN
d0 DATA NOT ON NETWORK
d1 INVALID DATA ON NETWORK
d4 INVALID SHARED DATA
b0 BLOWER MOTOR NOT RUNNING
b1 BLOWER MOTOR COMMUNICATION ERROR
b2 BLOWER MOTOR HP MISMATCH
b3
BLOWER MOTOR OPERATING IN POWER, TEM
P., OR SPEED
LIMIT
b4 BLOWER MOTOR CURRENT TRIP OR LOST ROTOR
b5 BLOWER MOTOR ROTOR LOCKED
b6 OVER/UNDER VOLTAGE TRIP OR OVER TEMPERATURE TRIP
b7 INCOMPLETE PARAMETER SENT TO MOTOR
b9 LOW INDOOR AIRFLOW
C1 LOW STAGE COOL - LEGACY MODE ONLY
C2 HIGH STAGE COOL - LEGACY MODE ONLY
P1 LOW STAGE HEAT PUMP HEAT - LEGACY MODE ONLY
P2 HIGH STAGE HEAT PUMP HEAT - LEGACY MODE ONLY
h1 EMERGENCY HEAT LOW - COMMUNICATING MODE ONLY
h2 EMERGENCY H
EAT HIGH - COMMUNICATING MODE ONLY
FC FAN COOL - COMMUNICATING MODE ONLY
FH FAN HEAT - COMMUNICATING MODE ONLY
F FAN ONLY
H1 ELECTRIC HEAT LOW
H2 ELECTRIC HEAT HIGH
dF
DEFROST - COMMUNICATING MODE ONLY
(Note: defrost is displayed as H1 in a legacy setup)
GREEN CFM LED - EACH FLASH REP RESENTS 100CFM (USE FOR AIRFLOW APPROXIMATION
ONLY) - EXAMPLE: 8 FLASHES = 800CFM

20
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
WARNING
Wiring Diagram

21
AIR HANDLER
AIR HANDLER HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDATIONS
We strongly recommend a bi-annual maintenance checkup be performed
before the heang and cooling seasons begin by a qualied servicer.
REPLACE OR CLEAN FILTER
IMPORTANT NOTE: Never operate unit without a lter installed
as dust and lint will build up on internal parts resulng in loss of
eciency, equipment damage and possible re.
An indoor air lter must be used with your comfort system. A
properly maintained lter will keep the indoor coil of your comfort
system clean. A dirty coil could cause poor operaon and/or severe
equipment damage.
Your air lter or lters could be located in your furnace, in a blower
unit, or in “lter grilles” in your ceiling or walls. The installer of your
air condioner or heat pump can tell you where your lter(s) are,
and how to clean or replace them.
Check your lter(s) at least once a month. When they are dirty,
replace or clean as required. Disposable type lters should be
replaced. Reusable type lters may be cleaned.
You may want to ask your dealer about high eciency lters. High
eciency lters are available in both electronic and non-electronic
types. These lters can do a beer job of catching small airborne
parcles.
MOTORS
Indoor and outdoor fan motors are permanently lubricated and do
not require addional oiling.
ALUMINUM INDOOR COIL CLEANING
(QUALIFIED SERVICER ONLY)
This unit is equipped with an aluminum tube evaporator coil. The
safest way to clean the evaporator coil is to simply ush the coil
with water. This cleaning pracce remains as the recommended
cleaning method for both copper tube and aluminum tube resi-
denal evaporator coils.
It has been determined that many coil cleaners and drain pan tab-
lets contain corrosive chemicals that can be harmful to aluminum
tube and n evaporator coils. Even a one-me applicaon of these
corrosive chemicals can cause premature aluminum evaporator coil
failure. Any cleaners that contain corrosive chemicals including,
but not limited to, chlorine and hydroxides, should not be used.
An alternate cleaning method is to use one of the products listed in
TP-109* to clean the coils. The cleaners listed are the only agents
deemed safe and approved for use to clean round tube aluminum
coils. TP-109 is also available on the web site in Partner Link >
Service Toolkit.
NOTE: Ensure coils are rinsed well aer use of any chemical cleaners.
BEFORE YOU CALL YOUR SERVICER
• Check the thermostat to conrm that it is properly set.
• Wait 15 minutes. Some devices in the outdoor unit or
in programmable thermostats will prevent compressor
operaon for awhile, and then reset automacally. Also,
some power companies will install devices which shut o
air condioners for several minutes on hot days. If you wait
several minutes, the unit may begin operaon on its own.
• Check the electrical panel for tripped circuit breakers or
open fuses. Reset the circuit breakers or replace fuses as
necessary.
• Check the disconnect switch near the indoor furnace or
blower to conrm that it is closed.
• Check for obstrucons on the outdoor unit . Conrm that
it has not been covered on the sides or the top. Remove
any obstrucon that can be safely removed. If the unit is
covered with dirt or debris, call a qualied servicer to clean
it.
• Check for blockage of the indoor air inlets and outlets.
Conrm that they are open and have not been blocked by
objects (rugs, curtains or furniture).
• Check the lter. If it is dirty, clean or replace it.
• Listen for any unusual noise(s), other than normal operang
noise, that might be coming from the outdoor unit. If you
hear unusual noise(s) coming from the unit, call a qualied
servicer.

22
Air Handler / Coil
ELECTRICAL
Line Voltage (Measure L1 and L2 Voltage) L1 - L2
Secondary Voltage (Measure Transformer Output Voltage) R - C
Blower Amps
Heat Strip 1 - Amps
Heat Strip 2 - Amps
BLOWER EXTERNAL STATIC PRESSURE
Return Air Stac Pressure IN. W.C.
Supply Air Stac Pressure IN. W.C.
Total External Stac Pressure (Ignoring +/- from the reading above, add total here) IN. W.C.
TEMPERATURES
Return Air Temperature (Dry bulb / Wet bulb)
DB °F WB °F
DB °F WB °F
Heang Supply Air Temperature DB °F
Temperature Rise DB °F
Delta T (Difference between Supply and Return Temperatures) DB °F
Air Handler / Coil - (Inverter Matched)
INVERTER AH / COIL ONLY
Check EEV and EEV wiring is secure (no adjustment required)
Addional Checks
Check wire roungs for any rubbing
Check product for proper draining
Check screw ghtness on blower wheel
Check factory wiring and wire connecons
Check product for proper clearances as noted by installaon instrucons
°F to °C formula: (°F - 32) divided by 1.8 = °C °C to °F formula: (°C mulplied by 1.8) + 32 = °F
Model Number
Serial Number
Cooling Supply Air Temperature (Dry bulb / Wet bulb)

23
THIS PAGE INTENTIONALLY LEFT BLANK

24
NOTE: SPECIFICATIONS AND PERFORMANCE DATE LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Visit our website at www.daikincomfort.com , www.goodmanmfg.com or www.amana-hac.com for informaon on:
• Products • Parts
• Warranes • Contractor Programs and Training
• Customer Services • Financing Opons
Daikin Comfort Technologies Manufacturing, Inc.
19001 Kermier Rd., Waller, TX 77484
©2026
is a registered trademark of Maytag or its related companies and is used under license. All rights reserved.
CUSTOMER FEEDBACK
We are very interested in all product comments.
Please ll out the feedback form on one of the following links:
Daikin Products: (https://daikincomfort.com/contact-us)
Goodman
®
Brand Products: (http://www.goodmanmfg.com/about/contact-us).
Amana
®
Brand Products: (http://www.amana-hac.com/about-us/contact-us).
You can also scan the QR code on the right for the product brand you
purchased to be directed to the feedback page.
DAIKIN
AMANA
®
BRAND
GOODMAN
®
BRAND