Honda EB10000 Industrial Generator

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual
  • Owner's Manual AG, AN types (mfg on or after 4/1/23) EBVC 1506962 - 9999999 - (English) Read Online | Download pdf
  • Owner's Manual AG, AN types EBVC 1501249 - 1506961 - (English) Download
  • Owner's Manual EBVC 1004170 - 1501248 - (English) Download
  • Owner's Manual EBVC 1000001 - 1004169 - (English) Download
Other Documents
  • AC Receptacle Selection EBVC 1000001 - 9999999 - (English) Download
  • Breather Heater Kit EBVC 1000001 - 9999999 - (English) Download
User Service
  • Common replacement parts guide EBVC 1000001 - 9999999 - (English) Download
EB10000 photo

Owner's Manual AG, AN types (mfg on or after 4/1/23) EBVC 1506962 - 9999999

This is the main product document for model EB10000. Additionally, the document applies to other Honda models: EB10000AN, EB10000AG

The file format is pdf, 120 pages, you can download this manual here .

background
PANTONE
186C
K
2024 Honda Motor Co., Ltd. -All Rights Reserved
C
EB10000
31Z26627
00X31-Z26-6270
Printed in China
英AH
FM
H i
GENERATOR
EB10000
Owner’s Manual
3mm
See page 12 for instructions on assembling your generator.
See page 17 for Initial Use Instructions.
background
Keep this owner’s manual handy so that you can refer to it any time.
This owner’s manual is considered a permanent part of the generator and
should remain with the generator if resold.
The information and specifications included in this publication were in effect at
the time of approval for printing. Honda Motor Co., Ltd. reserves the right,
however, to discontinue or change specifications or design at any time without
notice and without incurring any obligation whatsoever.
The illustration may vary according to the type.
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other
reproductive harm.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.
background
1
INTRODUCTION
Thank you for purchasing a Honda generator.
We would like to help you get the best results from your new generator and to
operate it safely. This manual contains the information on how to do that; please
read it carefully.
We suggest you read the "Distributor’s Limited Warranty" (see page 102) to fully
understand its coverage and your responsibilities of ownership.
When your generator needs scheduled maintenance, keep in mind that your
Honda servicing dealer is specially trained in servicing Honda generators and is
supported by the parts and service divisions of American Honda. Your Honda
servicing dealer is dedicated to your satisfaction and will be pleased to answer
your questions and concerns.
background
2
INTRODUCTION
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important.
We have provided important safety messages in this manual and on the
generator. This information alerts you to potential hazards that could hurt you
or others. Please read these messages carefully.
Of course, it is not practical or possible to warn you about all the hazards
associated with operating or maintaining a generator. You must use your own
good judgment.
You will find important safety information in a variety of forms:
• Safety Labels — on the generator.
• Instructions — how to use this generator correctly and safely.
• Safety Headings — such as IMPORTANT SAFETY INFORMATION.
• Safety Messages — preceded by a safety alert symbol and one of three
signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
This entire book is filled with important safety information - please read it
carefully.
DAMAGE PREVENTION MESSAGES
In addition to the above, you will find information preceded by a symbol.
That information is intended to help you avoid damage to your generator, other
property, or the environment.
You WILL be KILLED or SERIOUSLY HURT if you do
not follow instructions.
You CAN be KILLED or SERIOUSLY HURT if you do
not follow instructions.
You CAN be HURT if you do not follow instructions.
background
3
CONTENTS
INTRODUCTION ................................................................................................ 1
GENERATOR SAFETY ........................................................................................ 7
IMPORTANT SAFETY INFORMATION................................................................................7
Operator Responsibility...................................................................................................7
Carbon Monoxide Hazards.............................................................................................8
Electric Shock Hazards .....................................................................................................9
Fire and Burn Hazards ......................................................................................................9
Refuel With Care...............................................................................................................10
Vehicles and Transportation Hazards.......................................................................10
SAFETY LABEL LOCATIONS................................................................................................11
ASSEMBLY....................................................................................................... 12
SAFETY......................................................................................................................................12
The Importance of Proper Assembly ........................................................................12
ASSEMBLY................................................................................................................................13
Unpacking ..........................................................................................................................13
Loose Parts .........................................................................................................................13
Handle Installation ..........................................................................................................14
Wheel Kit Installation......................................................................................................15
Hanger Kit Installation ...................................................................................................16
INITIAL USE INSTRUCTIONS........................................................................... 17
ENGINE OIL..............................................................................................................................17
ENGINE OIL RECOMMENDATIONS..................................................................................18
FUEL...........................................................................................................................................19
FUEL RECOMMENDATIONS...............................................................................................21
CONTROLS & FEATURES................................................................................. 22
COMPONENT & CONTROL LOCATIONS ........................................................................22
CONTROLS...............................................................................................................................24
Fuel Valve Lever................................................................................................................24
Engine Switch....................................................................................................................24
Choke Knob........................................................................................................................24
CO-MINDER (CO Shut-off System) .............................................................................25
AC Circuit Protectors ......................................................................................................27
AC Circuit Breaker............................................................................................................28
Ground Fault Circuit Interrupter (GFCI) ...................................................................29
Auto Throttle® System ...................................................................................................31
Folding Handle .................................................................................................................32
FEATURES ................................................................................................................................33
Oil Alert® System..............................................................................................................33
i-Monitor .............................................................................................................................34
background
4
CONTENTS
Ground Terminal..............................................................................................................38
Fuel Gauge .........................................................................................................................39
BEFORE OPERATION....................................................................................... 40
ARE YOU READY TO GET STARTED? ...............................................................................40
Knowledge .........................................................................................................................40
IS YOUR GENERATOR READY TO GO?............................................................................40
Check the Engine.............................................................................................................41
Check the GFCI..................................................................................................................41
Check the Battery.............................................................................................................41
AC Appliance and Power Cord....................................................................................42
ENGINE OIL LEVEL CHECK ..................................................................................................43
AIR FILTER CHECK .................................................................................................................44
SAFE OPERATING PRECAUTIONS ....................................................................................46
OPERATION ..................................................................................................... 47
STARTING THE ENGINE .......................................................................................................47
STOPPING THE ENGINE.......................................................................................................51
HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)
................................................................................................................................................52
GFCI OPERATION CHECK....................................................................................................53
GFCI System ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A Receptacles)...........................54
GFCI System ②
(120V-20A Duplex Receptacle) ...................................................................................56
AC OPERATION ......................................................................................................................59
AC Applications ................................................................................................................60
AUTO THROTTLE® SYSTEM ................................................................................................61
STANDBY POWER..................................................................................................................62
Connections to a Building’s Electrical System.......................................................62
System Ground.................................................................................................................62
Special Requirements.....................................................................................................63
SERVICING YOUR GENERATOR ...................................................................... 64
THE IMPORTANCE OF MAINTENANCE...........................................................................64
MAINTENANCE SAFETY ......................................................................................................65
Safety Precautions...........................................................................................................65
MAINTENANCE SCHEDULE................................................................................................66
ENGINE OIL CHANGE ...........................................................................................................67
AIR CLEANER SERVICE .........................................................................................................68
Foam Air Filter Cleaning................................................................................................68
SEDIMENT CUP CLEANING ................................................................................................69
SPARK PLUG SERVICE ..........................................................................................................71
background
5
CONTENTS
SPARK ARRESTER SERVICE .................................................................................................73
BATTERY SERVICE..................................................................................................................75
Emergency Procedures..................................................................................................75
Battery Inspection ...........................................................................................................77
Battery Removal ...............................................................................................................78
Battery Charging..............................................................................................................79
Battery Installation ..........................................................................................................79
FUSE...........................................................................................................................................80
STORAGE ......................................................................................................... 81
STORAGE PREPARATION ....................................................................................................81
Cleaning ..............................................................................................................................81
Fuel .......................................................................................................................................81
Engine Oil ...........................................................................................................................85
Engine Cylinder ................................................................................................................85
STORAGE PRECAUTIONS....................................................................................................86
REMOVAL FROM STORAGE................................................................................................86
TRANSPORTING .............................................................................................. 87
TAKING CARE OF UNEXPECTED PROBLEMS ................................................. 89
ENGINE WILL NOT START ...................................................................................................89
ENGINE LACKS POWER........................................................................................................90
NO POWER AT THE AC RECEPTACLES ...........................................................................90
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR
FLASHING ...........................................................................................................................91
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING....................................................................................................91
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING
THE ENGINE........................................................................................................................91
TECHNICAL INFORMATION............................................................................ 92
SERIAL NUMBER LOCATION..............................................................................................92
CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION.......................93
EMISSION CONTROL SYSTEM INFORMATION.............................................................94
Air Index ...................................................................................................................................96
SPECIFICATIONS....................................................................................................................97
WIRING DIAGRAM.................................................................................................................99
CONSUMER INFORMATION.......................................................................... 100
DEALER LOCATOR INFORMATION...............................................................................100
Honda PUBLICATIONS......................................................................................................100
CUSTOMER SERVICE INFORMATION ...........................................................................101
background
6
CONTENTS
Distributor’s Limited Warranty .................................................................................... 102
Emission Control System Warranty ............................................................................107
REGISTRATION .................................................................................................................... 112
INDEX ............................................................................................................ 113
QUICK REFERENCE INFORMATION.......................................inside back cover
background
7
GENERATOR SAFETY
IMPORTANT SAFETY INFORMATION
Honda generators are designed for use with electrical equipment that has
suitable power requirements. Other uses can result in injury to the operator or
damage to the generator and other property.
Most injuries or property damage can be prevented if you follow all instructions
in this manual and on the generator. The most common hazards are discussed
below, along with the best way to protect yourself and others.
Operator Responsibility
• Never attempt to modify the generator. It can cause an accident as well as
damage to the generator and appliances.
• Know how to stop the generator quickly in case of emergency.
• Understand the use of all generator controls, output receptacles, and
connections.
• Be sure that anyone who operates the generator receives proper instruction.
• Protect children by keeping them at a safe distance from the generator.
• Obey all applicable laws and regulations where the generator is used.
background
GENERATOR SAFETY
8
Carbon Monoxide Hazards
A generator's exhaust contains toxic carbon monoxide, which you cannot see or
smell. Breathing carbon monoxide can KILL YOU IN MINUTES. To avoid carbon
monoxide poisoning, follow these instructions when operating a generator:
• Only run a generator OUTSIDE, far away from windows, doors, and vents with
engine exhaust directed away from occupied structures.
• Never operate a generator inside a house, garage, basement, crawl space, any
type of vehicle, trailer, or boat, or any enclosed or partly enclosed space.
• Never operate a generator near open doors, windows, vents, or hatches.
• Get fresh air and seek medical attention immediately if you suspect you have
inhaled carbon monoxide.
Early symptoms of carbon monoxide exposure include headache, fatigue,
shortness of breath, nausea, and dizziness. Continued exposure to carbon
monoxide can cause loss of muscular coordination, loss of consciousness, and
then death.
To alert you to potentially dangerous levels of carbon monoxide coming from a
generator operating outside or from other sources, install battery operated
carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-
up on every level of your home, outside sleeping areas, inside any type of
vehicle, trailer, or boat in accordance with the alarm’s instructions.
CO-MINDER:
This generator is equipped with a CO-MINDER system that automatically stops
the engine before the surrounding carbon monoxide concentration exceeds a
certain concentration.
• Do not modify the CO-MINDER.
• The CO-MINDER cannot prevent all danger associated with or caused by
carbon monoxide. Pay careful attention to the location of the generator (see
page 25).
background
GENERATOR SAFETY
9
Electric Shock Hazards
The generator produces enough electric power to cause a serious shock or
electrocution if misused.
• Do not use in wet conditions. Keep the generator dry.
– Do not use in the rain or snow.
– Do not use near pool or a sprinkler system.
– Do not use when your hands are wet.
• If the generator is stored outdoors, unprotected from the weather, check all
of the electrical components on the control panel before each use. Moisture
or ice can cause a malfunction or short circuit in electrical components that
could result in electrocution.
• Do not connect to a building’s electrical system unless an isolation switch has
been installed by a qualified electrician.
Fire and Burn Hazards
• The exhaust system gets hot enough to ignite some materials.
– Keep the generator at least 3 feet (1 meter) away from buildings and any
type of vehicle, trailer, boat, or other equipment during operation.
– Do not enclose the generator in any structure.
– Keep flammable materials away from the generator.
– Generators with standard equipment transport wheels must not be
operated with the wheels and/or stands removed.
– Do not block intake or exhaust vents, hoses, ports, or restrict air into or
away from generator.
– Do not add, remove, or modify covers, panels, cowlings, or straps.
• The muffler becomes very hot during operation and remains hot for a while
after stopping the engine. Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator.
• Do not pour the water directly on the generator to put out the fire when it
occurs. Use an appropriate fire extinguisher specially designed for electric fire
or oil fire.
background
GENERATOR SAFETY
10
Refuel With Care
Gasoline is highly flammable, and gasoline vapor can explode.
• Do not refuel during operation.
• Allow the engine to cool if it has been in operation.
• Refuel only outdoors in a well-ventilated area and on a level surface.
• Never smoke near gasoline, and keep other flames and sparks away.
• Do not overfill the fuel tank.
• Make sure that any spilled fuel has been wiped up and cleaned before
starting the engine.
• Always store gasoline in an approved container.
Vehicles and Transportation Hazards
• Do not operate the generator while it is being transported or while it is
mounted to any type vehicle, trailer, or boat.
• Do not operate the generator when it is in a storage, cargo, or security
enclosure, including any RV generator bay.
• Always completely remove the generator from the vehicle, RV, truck, trailer,
boat, other equipment or structure during operation.
• The generator must remain stationary while in operation.
background
GENERATOR SAFETY
11
SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious injury. Read
them carefully.
If a label comes off or becomes hard to read, contact your servicing dealer for a
replacement.
31Z266270.book 11 ページ 2023年10月24日 火曜日 午後2時35分
background
12
ASSEMBLY
SAFETY
The Importance of Proper Assembly
Proper assembly is essential to operator safety and the reliability of the
machine.
We cannot warn you of every conceivable hazard that can arise in performing
this assembly. Only you can decide whether or not you should perform a given
task.
Improper assembly can cause an unsafe
condition.
Failure to properly follow assembly
procedures can lead to serious injury or
death.
Follow the procedures and precautions
in this owner’s manual carefully.
background
ASSEMBLY
13
ASSEMBLY
Unpacking
1. Remove the generator and loose parts box from the carton.
2. Compare the loose parts with the inventory list below.
Tools Required: 12 mm wrench (2), pliers
Do not add fuel or oil before tipping the generator. Oil or fuel may damage the
engine or your property.
Loose Parts
Check all loose parts against the following list. Contact your dealer if any of the
loose parts shown below are not included with your generator.
Ref. No. Description Qty. Ref. No. Description Qty.
1Wheel 2 9Spring Washer 2
2 Axle Shaft 1 10 Handle holder bolt 2
3 Handle assy 1 11 8×45 mm Flange bolt 2
4 Stand 2 12 8×16 mm Flange bolt 4
5 20 mm Plain Washer 2 13 8×20 mm Flange bolt 4
6 4.0×28 mm Split pin 2 14 Hanger 1
7 Collar 2 15 Hanger bracket 1
812 mm Washer 2
①
②
③
⑭
⑮
⑬
⑫
⑪⑩
④
⑨⑧⑦⑥⑤
background
ASSEMBLY
14
Handle Installation
Install the handle assembly on the generator upper frame using the 12 mm
washers, spring washers and handle holder bolts.
Torque: 19.5 lbf·ft (26.5 N·m, 2.7 kgf·m)
TO EXTEND HANDLE:
Raise the handle to the horizontal position. The handle will click into place when
locked.
Pressing down on the handles may damage the handle holder assembly. Only pull
up on the handles to move the generator.
HANDLE HOLDER BOLT (2)
SPRING WASHER (2)
12 mm WASHER (2)
HANDLE ASSEMBLY
HANDLE LEVER
HANDLE
background
ASSEMBLY
15
Wheel Kit Installation
1. Install the two stands on the under frame using two 8×20 mm flange bolts,
two 8×45 mm flange bolts, and two collars.
2. Install the two wheels on the axle shaft using the plain washers and split pins.
After installing the split pins, bend the pins to ensure that the wheels are
secured to the axle.
3. Install the axle assembly on the generator using four 8×16 mm flange bolts.
Torque: 19.5 lbf·ft (26.5 N·m, 2.7 kgf·m)
8×20 mm
FLANGE BOLT (2)
COLLAR (2)
STAND (2)
AXLE SHAFT
WHEEL (2)
20 mm
PLAIN WASHER (2)
4.0×28 mm
SPLIT PIN (2)
8×45 mm
FLANGE BOLT (2)
8×16 mm
FLANGE BOLT (4)
background
ASSEMBLY
16
Hanger Kit Installation
1. Remove the center beam.
2. Loosely install the hanger to the center beam using the hanger bracket and
two 8×20 mm flange bolts.
3. Reinstall the center beam. Make sure to tighten the four 8×16 mm bolts
securely.
4. Position the hanger at the generator’s center, and tighten the two 8×20 mm
bolts securely.
Torque: 19.5 lbf·ft (26.5 N·m, 2.7 kgf·m)
8×20 mm FLANGE BOLT (2)
HANGER BRACKET
CENTER BEAM
8×16 mm
FLANGE BOLT (4)
HANGER
background
17
INITIAL USE INSTRUCTIONS
ENGINE OIL
The generator is shipped WITHOUT OIL in the engine.
1. Place the generator on a level surface.
2. Open the maintenance cover.
3. Remove the oil filler cap and oil level dipstick.
4. Add enough oil to bring the oil level to the upper limit mark on the oil
dipstick. SAE 10W-30 API service category SJ or later (or equivalent) is
recommended for general use; for additional recommendations (see
page 18).
Maximum oil capacity:
Without oil filter replacement: approximately 1.6 US qt (1.5 L)
With oil filter replacement: approximately 1.8 US qt (1.7 L)
Do not overfill the engine with oil. If the engine is overfilled, the excess oil
may be transferred to the air cleaner housing and air filter.
5. Reinstall the oil level dipstick and filler cap.
6. Close the maintenance cover.
MAINTENANCE COVER
UPPER LIMIT
LOWER LIMIT
OIL FILLER CAP
OIL LEVEL DIPSTICK
background
INITIAL USE INSTRUCTIONS
18
ENGINE OIL RECOMMENDATIONS
Oil is a major factor affecting performance and service life. Use 4-stroke
automotive detergent oil.
SAE 10W–30 is recommended for general use. Other viscosities shown in the
chart may be used when the average temperature in your area is within the
recommended range.
Read the instructions on the oil container before use.
The SAE oil viscosity and service category are in the API label on the oil
container. Honda recommends that you use API service category SJ or later (or
equivalent) oil.
AMBIENT TEMPERATURE
background
INITIAL USE INSTRUCTIONS
19
FUEL
Add fuel to the generator in a well-ventilated area. Fuel only outdoors. Keep
gasoline away from appliance, such as pilot lights, barbecues, electric
appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes
environmental damage. Fuel carefully to avoid spilling fuel. Wipe up spills
immediately. Do not fill the fuel tank above the upper level mark (red) on the
fuel strainer. After fueling, reinstall the fuel tank cap securely.
When appropriate, with the engine stopped, check the fuel gauge for the fuel
level. If the fuel level is low, wait for the generator to cool off and refill the fuel
tank.
This engine is certified to operate on unleaded gasoline with a pump octane
rating 86 or higher. Refer to "FUEL RECOMMENDATIONS" (see page 21) for
additional fuel recommendations.
Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel
tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited
Warranty.
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.
background
INITIAL USE INSTRUCTIONS
20
1. Remove the fuel tank cap.
2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper
level mark (red) on the fuel strainer.
3. After refueling, reinstall the fuel tank cap securely.
Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel
tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited
Warranty.
Move the generator at least 10 feet (3 meters) away from the fueling source and
site before starting the engine.
FUEL TANK CAP
TETHER
EMPTY
FUEL GAUGE
FULL
UPPER LEVEL MARK (RED)
UPPER LEVEL MARK (RED)
background
INITIAL USE INSTRUCTIONS
21
FUEL RECOMMENDATIONS
This engine is certified to operate on regular unleaded gasoline with a pump
octane rating of 86 or higher.
Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting
dirt or water in the fuel tank.
You may use regular unleaded gasoline containing no more than 10% ethanol
(E10) or 5% methanol by volume. In addition, methanol must contain cosolvents
and corrosion inhibitors.
Use of fuels with content of ethanol or methanol greater than shown above may
cause starting and/or performance problems. It may also damage metal, rubber,
and plastic parts of the fuel system.
Engine damage or performance problems that result from using a fuel with
percentages of ethanol or methanol greater than shown above and leaded
gasoline are not covered under the Distributor Limited Warranty.
If your equipment will be used on an infrequent basis, refer to the fuel section of
"STORAGE" chapter (see page 81) for additional information regarding fuel
deterioration.
background
22
CONTROLS & FEATURES
COMPONENT & CONTROL LOCATIONS
Use the two illustrations on these pages to locate and identify the most
frequently used controls.
GFCI TEST BUTTON
AC CIRCUIT PROTECTORS
LED
AC CIRCUIT BREAKER
ENGINE SWITCH
CHOKE KNOB
i-MONITOR
GROUND TERMINAL
AUTO THROTTLE SWITCH
RECEPTACLES GFCI RECEPTACLES
CONTROL PANEL
CO-MINDER
background
CONTROLS & FEATURES
23
FUSE
FUEL TANK CAP
FUEL GAUGE
MUFFLER
SPARK PLUG CAPFUEL VALVE LEVER
AIR CLEANER
OIL LEVEL DIPSTICK
OIL FILLER CAP
MAINTENANCE COVER
BATTERY
SPARK PLUG CAP
OIL FILTER OIL DRAIN BOLT
background
CONTROLS & FEATURES
24
CONTROLS
Fuel Valve Lever
The fuel valve lever is located between
the fuel tank and carburetor.
The fuel valve lever must be in the ON
position for the engine to run.
After stopping the engine, turn the
fuel valve lever to the OFF position.
Engine Switch
The engine switch controls the
ignition system, and it operates the
electric starter.
OFF – Stops the engine. The engine
switch key can be removed/inserted.
ON – Running position.
START – Operates the electric starter.
Choke Knob
The choke knob opens and closes the
choke valve in the carburetor.
The CLOSED position enriches the fuel
mixture for starting a cold engine.
The OPEN position provides the
correct fuel mixture for operation after
starting, and for restarting a warm
engine.
FUEL VALVE LEVER
OFF
ON
ON
OFF
START
ENGINE SWITCH
OPEN
CLOSED
CHOKE KNOB
background
CONTROLS & FEATURES
25
CO-MINDER (CO Shut-off System)
CO-MINDER is a system that automatically stops the engine before the
surrounding carbon monoxide concentration exceeds a certain level.
If the CO-MINDER detects a high carbon monoxide concentration, the engine
will stop and the CO ALARM indicator will flash for about five minutes.
Continuously using the generator in areas with high concentrations of carbon
monoxide can cause serious health hazards due to carbon monoxide poisoning
(see page 8). If you are in the same area as the generator, evacuate the area
immediately. Get fresh air and seek medical attention immediately if you feel
sick or suspect you have inhaled carbon monoxide. Ventilate the area or space
where the generator is located.
If the engine is stopped by the CO-MINDER system, change the operating
location of the generator.
• Do not operate the generator in an enclosed or partly enclosed area such as a
garage.
• Do not enclose or cover the generator with boards or a tent, even when it is
outside and away from of a building.
• Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other
structures, or vehicles.
• Avoid placing the generator near devices that emit carbon monoxide, such as
another generator.
CO-MINDER RESET BUTTON
CO ALARM INDICATOR
FAULT/CO SENSOR LIFE
INDICATOR
background
CONTROLS & FEATURES
26
RESTARTING THE ENGINE
When the engine is stopped automatically by CO-MINDER, press the CO-
MINDER reset button to restart the engine.
If the engine is restarted without pressing the CO-MINDER reset button, the
engine will automatically stop immediately after restarting and the CO ALARM
indicator will flash for approximately five minutes.
Resetting the CO-MINDER is possible only after the CO ALARM indicator is
turned off.
CO-MINDER MALFUNCTION DETECTION
If the CO-MINDER detects a system malfunction, the engine will stop
automatically and the FAULT/CO SENSOR LIFE indicator will flash for
approximately five minutes. Press the CO-MINDER reset button to turn off the
FAULT/CO SENSOR LIFE indicator. If the engine will not remain running after
attempting to restart it and the FAULT/CO SENSOR LIFE indicator comes on
again, there may be a system malfunction. If this occurs, do not attempt to
restart the generator more than two times. If the CO-MINDER system is
malfunctioning, it cannot warn you of potential high concentrations of carbon
monoxide. Move the generator to a well-ventilated location and consult an
authorized Honda Power Equipment dealer.
CO SENSOR LIFE
If the FAULT/CO SENSOR LIFE indicator flashes when operating the generator,
the CO-MINDER may be reaching the end of its useful lifespan and will
eventually need replacement.
• If the indicator flashes once every four seconds, this means there is
approximately six months to one year of life left in the CO-MINDER.
• If the indicator flashes once every two seconds, this means there is
approximately six months of life or less left in the CO-MINDER.
• The FAULT/CO SENSOR LIFE indicator indicates the estimated life left in the CO-
MINDER.
• The generator stopping period and storage period are also included in the useful
lifespan of the CO-MINDER.
• Contact an authorized Honda Power Equipment dealer for CO-MINDER
replacement.
background
CONTROLS & FEATURES
27
AC Circuit Protectors
The AC circuit protectors will automatically switch to OFF if there is a short
circuit or a significant overload of the generator at each receptacle. If an AC
circuit protector switches OFF automatically, check that the appliance is
working properly and does not exceed the rated load capacity of the circuit
before resetting the AC circuit protector ON.
AC CIRCUIT PROTECTOR for Receptacle
AC CIRCUIT PROTECTOR for Receptacle
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
120 V 30 A
120/240 V 30 A
PUSH
ON
OFF
AC CIRCUIT PROTECTOR
for Receptacle
AC CIRCUIT PROTECTOR for Receptacle
AC CIRCUIT PROTECTOR for Receptacle
OFF
ON
background
CONTROLS & FEATURES
28
AC Circuit Breaker
The AC circuit breaker will automatically switch OFF in the following cases.
• If there is a short circuit or a significant overload at the receptacles.
• If there is a ground-fault current from either receptacles A, B or C.
The AC circuit breaker may be used to switch the generator power ON or OFF.
RECEPTACLE A
(120/240 V 37.5 A)
AC CIRCUIT BREAKER RECEPTACLE D
(120 V 20 A DUPLEX RECEPTACLES)
RECEPTACLE C
(120 V 30 A)
RECEPTACLE B
(120/240 V 30 A)
OFF
ON
background
CONTROLS & FEATURES
29
Ground Fault Circuit Interrupter (GFCI)
This generator has two types of Ground Fault Circuit Interrupter (GFCI) systems,
GFCI system ① and GFCI system ②.
GFCI SYSTEM ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A RECEPTACLES)
If there is a ground-fault current from either A, B or C receptacle, it will shut off
the power to receptacles A, B, and C.
If this GFCI system ① activates, the AC circuit breaker will be switched to OFF
position and it will shut off power to all receptacles, including GFCI system ②
120 V 20 A DUPLEX RECEPTACLES.
GFCI SYSTEM ②
(120V-20A DUPLEX RECEPTACLE)
If there is a ground-fault current from either 120 V 20 A DUPLEX RECEPTACLE,
then the GFCI System ② will shut off the power to that 120 V 20 A DUPLEX
RECEPTACLE. GFCI system ① will not be affected.
AC CIRCUIT
BREAKER
RECEPTACLE C
(120 V 30 A)
GFCI SYSTEM ②
(120V-20A DUPLEX RECEPTACLES)
GFCI SYSTEM ①
(120V-30A, 120V/240V-30A, 120V/240 V-37.5 A RECEPTACLES)
RECEPTACLE B
(120/240 V 30 A)
RECEPTACLE A
(120/240 V 37.5 A)
background
CONTROLS & FEATURES
30
All receptacles on the generator are protected by a Ground Fault Circuit
Interrupter (GFCI) for protection against the shock hazard of ground-fault
current.
An example of ground-fault current is the current that would flow through a
person who is using an appliance with faulty insulation and, at the same time, is
in contact with an electrical ground such as a plumbing fixture, wet floor, or
earth. The GFCI will protect against current flowing through that person.
The GFCI will not protect against short circuits or overloads.
GFCIs can be expected to interrupt power supply if there are ground faults or
stray current imposed on the wiring by other electrical devices, wiring, or
equipment. Due to the risk of a power interruption, this generator is not
recommended for powering medical or life support equipment.
120/240 V 30 A RECEPTACLE
GFCI RECEPTACLES
(120 V 20 A DUPLEX RECEPTACLES)
120/240 V 37.5 A RECEPTACLE 120 V 30 A RECEPTACLE
background
CONTROLS & FEATURES
31
Auto Throttle® System
The Auto Throttle® system automatically reduces engine speed when all loads
are turned off or disconnected. When appliances are turned on or reconnected,
the engine returns to the rated speed.
SWITCH POSITION
ON - Recommended to minimize fuel consumption and further reduce noise
levels when no load is applied to the generator.
OFF - The Auto Throttle system does not operate. Recommended to minimize
warm-up time when the generator is started and when starting a load with
large start-up power requirements.
AUTO THROTTLE SWITCH
ON
OFF
OFF
ON
background
CONTROLS & FEATURES
32
Folding Handle
The foldable handle is intended for ease of transportation and should be folded
when the generator is stationary. Do not rest objects on the extended handle.
To extend the handle, lift handle upward. Lock levers will lock and secure the
handle into place.
To fold the handle,
1. Press both handle lock levers downward.
2. Lower the handle.
HANDLE LOCK LEVER
HANDLE
Handle
transport
position
Generator
stationary
position
background
CONTROLS & FEATURES
33
FEATURES
Oil Alert® System
The Oil Alert® system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
can fall below a safe limit, the Oil Alert indicator will come on and the Oil Alert
system automatically will stop the engine (the engine switch will remain in the
ON position).
The i-Monitor display will show “OIL” on the screen and the Oil Alert indicator
will illuminate.
If the engine stops or the Oil Alert indicator comes on when you turn the engine
switch to the START position, check the engine oil level (see page 43) before
troubleshooting in other areas.
Even when oil is added to the engine, the generator will not restart until the Oil
Alert indicator is reset. To reset the Oil Alert indicator, turn the engine switch to
the OFF position, add the proper amount of oil (see page 67), and then turn the
engine switch back to the ON position.
OIL ALERT INDICATOR (RED)
background
CONTROLS & FEATURES
34
i-Monitor
The i-Monitor is a user interface that allows the operator to view (when the
generator is running) total operating time in hours, generator output voltage,
battery voltage, and error messages.
i-Monitor at Start Up
When the engine switch is turned to the ON position, all segments of the i-
Monitor display turn on for a second.
After showing all segments, the i-Monitor shows current accumulated hours
and the battery voltage alternately for three seconds.
When the engine is started and the generator works, the i-Monitor shows
output voltage.
Backlight blinks
If you turn the engine switch to the ON position but then don’t start the engine
within 1 minute, the display starts to blink.
Start the engine or turn the engine switch to the OFF position.
The display also blinks when the engine stops due to an error. In such a case, the
display starts to blink as soon as the engine stops.
background
CONTROLS & FEATURES
35
i-Monitor Display
The four-digit screen displays the total operating hours, battery voltage, and
power output voltage or any activated error messages.
Total Operating Hours
This mode displays the total operating hours of the generator. When the
generator is running, the total operating time accumulates.
The total operating hours can show from 0 up to 9,999 hours. When it reaches
10,000 hours, the display returns to ‘‘0’’.
When the total operating hours reach 29,999 hours, the i-monitor will
continuously show 9,999 hours.
Base the generator’s maintenance schedule on the accumulated time
displayed.
FOUR-DIGIT SCREEN DISPLAY
background
CONTROLS & FEATURES
36
Power Output Voltage
This mode displays an approximate single-phase output voltage.
Battery Voltage
This mode displays the battery condition, expressed in Volts DC.
The battery voltage can be displayed from 8 V up to 16 V.
When the battery voltage is less than 8 V, the i-Monitor shows 8 V. When above
16 V, 16 V is shown.
In this generator, the engine will not start if the battery is removed. Also, if the
battery is disconnected when the generator is operating, the engine will stop.
background
CONTROLS & FEATURES
37
i-Monitor System Error Messages
If the generator has a system malfunction, it will show an error message on the
i-Monitor display. If an error message displays, contact an authorized Honda
Power Equipment dealer.
When there are a number of errors, they are indicated alternately for two
seconds for each.
Error code Type of error Consequence · treatment
E-04 Engine over rev Engine stops
E-31 High AC voltage Engine stops
E-32 ROM/RAM failure Engine stops
E-33 FET overheat Generator stops
------ Communication error Contact an authorized
Honda Power Equipment
dealer.
----h Failed to read out
accumulated hours
Contact an authorized
Honda Power Equipment
dealer.
ERROR MESSAGE
(Example: E-04)
background
CONTROLS & FEATURES
38
Ground Terminal
The ground terminal is connected to the frame of the generator, the metal non-
current-carrying parts of the generator, and the ground terminals of each
receptacle.
Before using the ground terminal, consult a qualified electrician, electrical
inspector, or local agency having jurisdiction for local codes or ordinances that
apply to the intended use of the generator.
NEUTRAL BONDED TO FRAME:
There is a permanent conductor between the generator (stator winding) and
the frame.
GROUND TERMINAL
background
CONTROLS & FEATURES
39
Fuel Gauge
The fuel gauge is a mechanical device that measures the fuel level in the tank.
The red indicator in the window will reference the level in relation to full or
empty. To provide increased operating time, start with a full tank before
beginning operation. Check the fuel level with the generator on a level surface.
Always refuel with the engine OFF and cool.
FUEL GAUGE
EMPTY
FULL
RED INDICATOR
background
40
BEFORE OPERATION
ARE YOU READY TO GET STARTED?
Your safety is your responsibility. A little time spent in preparation will
significantly reduce your risk of injury.
Knowledge
Read and understand this manual. Know what the controls do and how to
operate them.
Familiarize yourself with the generator and its operation before you begin using
it. Know how to quickly shut off the generator in case of an emergency.
If the generator is being used to power appliances, be sure that they do not
exceed the generator’s load rating (see page 60).
IS YOUR GENERATOR READY TO GO?
For your safety, to ensure compliance with environmental regulations, and to
maximize the service life of your equipment, it is very important to take a few
moments before you operate the generator to check its condition. Be sure to
take care of any problem you find, or have your servicing dealer correct it,
before you operate the generator.
To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from
building walls, vehicles, and other equipment during operation. Do not place
flammable objects close to the engine or exhaust.
Failure to properly maintain this
generator, or failing to correct a problem
before operation, could result in a
significant malfunction.
Some malfunctions can cause serious
injuries or death.
Always perform a pre-operation
inspection before each operation and
correct any problems.
background
BEFORE OPERATION
41
Before beginning your pre-operation checks, be sure the generator is on a level
surface and the engine switch is in the OFF position.
Generators with standard equipment transport wheels must not be operated with
the wheels and/or stands removed or else the generator may not operate correctly
and can become damaged.
Check the Engine
• Before each use, look around and underneath the engine for signs of oil or
gasoline leaks.
• Check the engine oil level (see page 43). A low engine oil level will cause the
Oil Alert system to shut down the engine.
• Check the air filters (see page 44). Dirty air filters will restrict air flow to the fuel
system, reducing engine and generator performance.
• Check the fuel level (see page 19). Starting with a full tank will help to
eliminate or reduce operating interruptions for refueling.
Check the GFCI
Check the GFCI operation (see page 53) after starting the engine.
Check the Battery
Check the electrolyte level (see page 77). If the electrolyte level is below the
LOWER level, sulfation and battery plate damage will occur.
UPPER LEVEL
LOWER LEVEL
BATTERY
background
BEFORE OPERATION
42
AC Appliance and Power Cord
Before connecting an AC appliance or power cord to the generator:
• Use grounded 3-prong extension cords, tools, and appliances, or double-
insulated tools and appliances.
• Inspect cords and plugs, and replace if damaged.
• Do not use cord lengths greater than 164 feet (50 meters), and do not use
multiple tools and appliances with built-in noise filters. Such use may activate
the GFCI and interrupt power supply.
• Make sure that the appliance is in good working order. Faulty appliances or
power cords can create a potential for electric shock.
• Make sure the electrical rating of the tool or appliance does not exceed the
rated power of the generator or the receptacle being used.
• Do not exceed the current limit specified for any one receptacle.
background
BEFORE OPERATION
43
ENGINE OIL LEVEL CHECK
Check the engine oil level with the engine stopped and in a level position.
1. Open the maintenance cover to access the oil level dipstick.
2. Remove the oil level dipstick and wipe it clean.
3. Fully insert the dipstick, then remove it to check the oil level.
4. If the level is near or below the lower limit mark on the dipstick, remove the
oil filler cap, and fill with the recommended oil (see page 18) to the upper
limit mark on the oil level dipstick.
5. Reinstall the oil level dipstick and filler cap.
6. Close the maintenance cover.
The Oil Alert system will automatically stop the engine before the oil level falls
below safe limits. However, to avoid the inconvenience of an unexpected
shutdown, check the oil level regularly.
MAINTENANCE COVER
UPPER LIMIT
LOWER LIMIT
OIL FILLER CAP
OIL LEVEL DIPSTICK
background
BEFORE OPERATION
44
AIR FILTER CHECK
1. Open the maintenance cover to access the air cleaner.
2. Pull the air cleaner cover latch to the unlocked position, and remove the
cover.
Remove the wing nut from the paper filter element.
Remove the paper filter element and foam filter element from the air cleaner
case.
Remove the foam filter element from the paper filter element.
3. Inspect both filter elements, and replace them if they are damaged. Always
replace the paper filter element at the scheduled interval (see page 66).
MAINTENANCE COVER
AIR CLEANER COVER LATCH
AIR CLEANER COVER
PAPER FILTER ELEMENT
AIR CLEANER CASE
WING NUT
FOAM FILTER ELEMENT
AIR CHAMBER
PACKING
background
BEFORE OPERATION
45
4. Clean the filter elements if they are to be reused.
Paper filter element: Tap the filter element several times on a hard surface to
remove dirt, or blow compressed air [not exceeding 30 psi (207 kPa, 2.1 kgf/
cm
2
)] through the filter element from the air cleaner case side.
Never try to brush off dirt; brushing will force dirt into the fibers. Replace the
paper filter element if it is excessively dirty.
Foam filter element: If the foam filter is dirty, clean it as described on page 68.
Replace the foam filter if it is damaged.
5. Wipe dirt from the inside of the air cleaner body and cover, using a moist rag.
Be careful to prevent dirt from entering the air chamber that leads to the
carburetor.
6. Place the foam filter element over the paper filter element, and reinstall the
assembled filter element. Be sure the packing is in place beneath the filter
element. Tighten the wing nut securely.
7. Lock the air cleaner cover latch securely.
8. Close the maintenance cover.
Operating the engine without the air filters, or with a damaged air filters, will allow
dirt to enter the engine, causing rapid engine wear. This type of damage is not
covered by the Distributor’s Limited Warranty.
background
BEFORE OPERATION
46
SAFE OPERATING PRECAUTIONS
Before operating the generator, review chapters "GENERATOR SAFETY" (see
page 7).
For your safety, do not operate the generator in an enclosed, or partly enclosed
area such as a garage (even if the door is open) or near structures or vehicles.
Your generator's exhaust contains poisonous carbon monoxide gas that can
collect rapidly in such areas, structures, vehicles, trailers, or boats.
• Do not operate the generator when it is in a storage, cargo, or security
enclosure, including any RV generator bay.
• Always completely remove the generator from the vehicle, trailer, boat or
other equipment or structure during operation.
• The generator must remain stationary while in operation.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.
background
47
OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from
building or trailer walls, vehicles, trailers, boats, and other equipment during
operation. Do not place flammable objects close to the engine.
• Operating this generator less than 3 feet (1 meter) from a building, obstruction, or
when it is in an enclosure, a storage or security compartment/bay, can cause
overheating and damage the generator.
• For proper cooling, allow at least 3 feet (1 meter) of empty space above and
around the generator.
• Since the CO-MINDER may detect the carbon monoxide concentration and the
engine may stop automatically, pay attention to the direction of exhaust and
where the generator is located (see page 25).
Refer to "SAFE OPERATING PRECAUTIONS" on page 46 and perform the "IS YOUR
GENERATOR READY TO GO?" checks (see page 40).
Refer to "AC OPERATION" (see page 59) for connecting loads to the generator.
1. Make sure that all appliances are
disconnected from the AC
receptacle.
2. Make sure that the AC circuit
breaker is in the OFF position.
AC CIRCUIT BREAKER
OFF
background
OPERATION
48
3. Turn the fuel valve lever to the ON
position.
4. Pull the choke knob to the CLOSED
position to start a cold engine.
Leave the choke knob in the OPEN
position to start a warm engine.
FUEL VALVE LEVER
OFF
ON
CHOKE KNOB
OPEN
CLOSED
background
OPERATION
49
5. Make sure the Auto Throttle switch
is in the OFF position, or more time
will be required for warm up.
6. Start the engine.
Turn the engine switch to the
START position, and hold it there
until the engine starts. When the
engine starts, release the key,
allowing the switch to return to the
ON position.
If the engine fails to start within 5
seconds, release the key, and wait
at least 10 seconds before
operating the starter again.
Using the electric starter for more than 5 seconds at a time will overheat the
starter motor and can damage it.
Do not leave the engine switch in the ON position when the generator is not
operating as the battery will be drained. Turn the engine switch to the OFF
position when not in use.
AUTO THROTTLE SWITCH
OFF
OFF
ENGINE SWITCH
OFF
ON
START
background
OPERATION
50
7. If the choke knob was pulled to the
CLOSED position to start the
engine, gradually move it to the
OPEN position as the engine warms
up.
8. If you wish to use the Auto Throttle
system, turn the Auto Throttle
switch to the ON position after the
engine has warmed up for 2 or 3
minutes.
CHOKE KNOB
OPEN
AUTO THROTTLE SWITCH
ON
ON
background
OPERATION
51
STOPPING THE ENGINE
To stop the engine in an emergency, simply turn the engine switch to the OFF
position. Under normal conditions, use the following procedure.
1. Turn off or disconnect all appliances
that are connected to the generator.
2. Switch the AC circuit breaker to the
OFF position.
3. Turn the engine switch to the OFF
position.
4. Turn the fuel valve lever to the OFF
position.
AC CIRCUIT BREAKER
OFF
ENGINE SWITCH
ON
OFF
FUEL VALVE LEVER
OFF
ON
background
OPERATION
52
HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)
When the engine is automatically stopped by the CO-MINDER, move the
generator to an area with fresh air and away from any device that may be
emitting carbon monoxide, such as another generator. Press the CO-MINDER
reset button and then follow the standard procedure for starting the engine.
When the CO ALARM indicator or the FAULT/CO-MINDER LIFE indicator flashes,
press the CO-MINDER reset button to turn off the indicator.
CO-MINDER RESET BUTTON
CO ALARM INDICATOR
FAULT/CO SENSOR LIFE
INDICATOR
background
OPERATION
53
GFCI OPERATION CHECK
Always check GFCI system ① and GFCI system ② operation before using the
generator.
A faulty GFCI system will not provide
proper protection against electric shock
as designed.
An electric shock can result in serious
injury or death.
Always perform the GFCI system
inspection before using the generator. If
the GFCI system fails the test, the
generator must be repaired by an
authorized Honda servicing dealer
before use.
GFCI SYSTEM ②
(120V-20A DUPLEX RECEPTACLES)
GFCI SYSTEM ①
(120V-30A, 120V/240V-30A, 120V/240 V-37.5 A RECEPTACLES)
background
OPERATION
54
GFCI System ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A Receptacles)
1. Unplug all tools and appliances from the generator.
2. Start the engine (see page 47).
3. Turn the AC circuit breaker to the ON position.
4. Press the GFCI TEST button. The LED comes on, and the AC circuit breaker
switches to the OFF position.
LED
120/240 V 30 A RECEPTACLE
GFCI TEST BUTTON
GFCI SYSTEM ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A RECEPTACLES)
120/240 V 37.5 A RECEPTACLE
AUTO THROTTLE SWITCH
AC CIRCUIT BREAKER
120 V 30 A RECEPTACLE
OFF
background
OPERATION
55
5. When you switch the AC circuit breaker to the ON position, LED will turn off.
If the GFCI and AC circuit breaker do not function as described, take the
generator to an authorized Honda Power Equipment dealer for repair.
• If the red GFCI indicator starts to blink continuously, contact an authorized
Honda Power Equipment dealer.
During generator use, if the AC circuit breaker trips, this usually indicates a
faulty power tool, appliance, or cord.
If that occurs, perform test steps 1 through 5 to verify that the GFCI and AC
circuit breaker are in proper working order. If the GFCI and AC circuit breaker do
test correctly, then the fault is likely to be in the power tool, appliance, or cord.
Repair or replace the faulty power tool, appliance, or cord before further use.
LED
ON
AC CIRCUIT BREAKER
background
OPERATION
56
GFCI System ②
(120V-20A Duplex Receptacle)
1. Unplug all tools and appliances from the generator.
2. Start the engine (see page 47).
3. Turn OFF the auto throttle switch (see page 49).
4. Turn the AC circuit breaker to the ON position. When the GFCI is operating
normally, the GFCI indicator will continuously light green.
Light order:
(red) Blink once (green) Lights continuously
• If the green GFCI indicator does not light on, press the GFCI RESET button.
• If the red GFCI indicator starts to blink continuously, contact an authorized
Honda Power Equipment dealer.
background
OPERATION
57
5. Press the GFCI TEST button:
• The GFCI RESET button will pop out and the green GFCI indicator will go
off.
• If the GFCI does not function as described, contact an authorized Honda
Power Equipment dealer.
AUTO THROTTLE SWITCH
GFCI SYSTEM ②
(120V-20A DUPLEX RECEPTACLES)
AC CIRCUIT BREAKER
GFCI TEST BUTTON
GFCI RESET BUTTON
GFCI INDICATOR
ON
background
OPERATION
58
6. Press the GFCI RESET button:
• The green GFCI indicator will light continuously.
• If the red GFCI indicator starts to blink continuously, contact an authorized
Honda Power Equipment dealer.
When the GFCI RESET button pops out or the green GFCI indicator does not lit
during operation:
• Unplug all appliances from the GFCI protected receptacle.
• Press the GFCI RESET button.
– If the GFCI cannot be reset, the GFCI is faulty. Contact an authorized
Honda Power Equipment dealer.
– If the GFCI RESET button extends, this usually indicates a faulty power
tool, appliance, or cord. If that occurs, perform operation check steps 1
through 6 to verify that the GFCI is in proper working order. If the GFCI
tests correctly, then the fault is likely to be in the power tool, appliance,
or cord. Repair or replace the faulty power tool, appliance, or cord before
further use.
GFCI RESET BUTTON
GFCI INDICATOR
background
OPERATION
59
AC OPERATION
If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is in the appliance or the rated load capacity of the
generator has been exceeded.
Substantial overloading may damage the generator. Marginal overloading may
shorten the service life of the generator.
1. Start the engine (see page 47).
2. Switch ON the AC circuit breaker.
3. Plug in the appliance.
4. Most motorized appliances require more than their rated wattage for startup.
5. Turn on the appliance.
Do not exceed the current limit specified for any of the receptacles.
If an overloaded circuit causes the AC circuit breaker or AC circuit protector to
switch OFF, reduce the electrical load on the circuit, wait a few minutes and
then reset the AC circuit breaker or AC circuit protector.
ON
AC CIRCUIT BREAKER
background
OPERATION
60
Before connecting an appliance to the generator, make sure that it is in good
order and that its electrical rating does not exceed that of the generator. Then
start the generator and connect the appliance power cord.
AC Applications
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. Faulty appliances or power cords
can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is the appliance or the rated load capacity of the
generator has been exceeded.
Most appliance motors require more than their rated wattage for startup.
Make sure the electrical rating of the tool or appliance does not exceed the
maximum power rating of the generator.
Maximum power is:
10.0 kVA
For continuous operation, do not exceed the rated power.
Rated power is:
9.0 kVA
In either case, the total power requirements (VA) of all appliances connected
must be considered. Appliance and power tool manufacturers usually list rating
information near the model number or serial number.
Substantial overloading will open the circuit breaker. Slightly overloading the
generator may not switch the circuit breaker OFF, but will shorten the service life of
the generator.
background
OPERATION
61
AUTO THROTTLE® SYSTEM
With the switch in the ON position, engine speed is automatically reduced when
ALL loads are turned OFF or disconnected. When appliances are turned ON or
reconnected, the engine returns to rated speed. In the OFF position, the Auto
Throttle® system does not operate. The Auto Throttle system will not respond to
electrical loads of less than 1 ampere or intermittent loads such as a staple gun.
Turn the Auto Throttle switch to the OFF position to operate loads of less than 1
amp.
Appliances with large start-up power demands may not allow the engine to
reach normal operating rpm when they are connected to the generator. Push
the Auto Throttle switch to the OFF position and connect the appliance to the
generator. If the engine still will not reach normal operating speed, check that
the appliance does not exceed the rated load capacity of the generator.
To avoid extended warm-up periods, keep the Auto Throttle switch OFF until
the engine reaches operating temperature.
The Auto Throttle system is not effective for use with appliances that require
only momentary power. If the tool or appliance will be turned ON and OFF
quickly, the Auto Throttle switch should be in the OFF position.
AUTO THROTTLE SWITCH
ON
OFF
OFF
ON
background
OPERATION
62
STANDBY POWER
Connections to a Building’s Electrical System
Connections for standby power to a building’s electrical system must be made
by a qualified electrician. The connection must isolate the generator power
from utility power, and must comply with all applicable laws and electrical
codes.
In some areas, generators are required by law to be registered with local utility
companies. Check local regulations for proper registration and use procedures.
System Ground
This generator has a system ground that connects generator frame components
to ground terminals in the AC output receptacles. The system ground is
connected to the AC neutral wire.
Improper connections to a building’s
electrical system can allow current from
the generator to backfeed into the
utility lines.
Such backfeed may electrocute utility
company workers or others who contact
the lines during a power outage, and the
generator may explode, burn, or cause
fires when utility power is restored.
Consult the utility company or a
qualified electrician prior to making any
power connections.
background
OPERATION
63
Special Requirements
There may be Federal or State Occupational Safety and Health Administration
(OSHA) regulations, local codes, or ordinances that apply to the intended use of
the generator. Please consult a qualified electrician, electrical inspector, or the
local agency having jurisdiction.
• In some areas, generators are required to be registered with local utility
companies.
• If the generator is used at a construction site, there may be additional
regulations that must be observed.
background
64
SERVICING YOUR GENERATOR
THE IMPORTANCE OF MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation.
It will also help reduce air pollution.
To help you properly care for your generator, the following pages include a
maintenance schedule, routine inspection procedures, and simple maintenance
procedures using basic hand tools. Other service tasks that are more difficult or
require special tools are best handled by professionals and are normally
performed by a Honda technician or other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If you
operate your generator under unusual conditions, such as sustained high-load
or high-temperature operation, or use it in dusty conditions, consult your
servicing dealer for recommendations applicable to your individual needs and
use.
Remember that an authorized Honda Power Equipment dealer knows your
generator best and is fully equipped to maintain and repair it.
To ensure the best quality and reliability, use only new, Honda Genuine parts or
their equivalents for repair and replacement.
Maintenance, replacement, or repair of the emission control devices and
systems may be performed by any engine repair establishment or
individual, using parts that are “certified” to EPA standards.
Failure to properly maintain this
generator, or failing to correct a problem
before operation, could result in a
significant malfunction.
Some malfunctions can cause serious
injuries or death.
Always follow the inspection and
maintenance recommendations and
schedules in this owner’s manual.
background
SERVICING YOUR GENERATOR
65
MAINTENANCE SAFETY
Some of the most important safety precautions follow. However, we cannot
warn you of every conceivable hazard that can arise in performing
maintenance. Only you can decide whether or not you should perform a given
task.
Safety Precautions
Read the instructions before you begin, and make sure you have the tools and
skills required.
• Make sure the engine is off before you begin any maintenance or repairs. This
will eliminate several potential hazards:
– Carbon monoxide poisoning from engine exhaust
Operate outside away from open windows or doors with engine exhaust
directed away from occupied structures.
– Burns from hot parts
Let the engine and exhaust system cool before touching.
– Injury from moving parts
Do not run the engine unless instructed to do so.
• To reduce the possibility of fire or explosion, be careful when working around
gasoline. Use only a non-flammable solvent, not gasoline, to clean parts. Keep
cigarettes, sparks, and flames away from all fuel-related parts.
Improper maintenance can cause an
unsafe condition.
Failure to properly follow maintenance
instructions and precautions can cause
serious injuries or death.
Always follow the procedures and
precautions in this owner’s manual.
background
SERVICING YOUR GENERATOR
66
MAINTENANCE SCHEDULE
Failure to follow this maintenance schedule could result in non-warrantable
failures.
(*)Replace paper element type only.
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, unless you have the proper tools and are
mechanically proficient. Refer to the Honda shop manual for service procedures.
See "Honda PUBLICATIONS" on page 100 for ordering information.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
REGULAR SERVICE PERIOD (3)
ITEM
Perform at every indicated month
or operating hour interval,
whichever comes first.
Each
use
First
month
or
20 Hrs.
Every 3
months
or
50 Hrs.
Every 6
months
or
100 Hrs.
Every
year
or
300 Hrs.
Page
Engine oil Check level o 43
Change o o 67
Engine oil filter Replace Every 200 Hrs. (2) —
Air cleaner Check o 44
Clean o (1) 44, 68
Replace o (*) 44
Battery electrolyte Check level o 77
GFCI operation Check o 53
Canister Check Every 2 years (2) —
Purge tube Check Every 2 years (2) —
Charge tube Check Every 2 years (2) —
Sediment cup Clean o 69
Spark plug Check-adjust o
71
Replace o
Spark arrester Clean o 73
Valve clearance Check-adjust o (2) —
Combustion chamber Clean After every 1,000 Hrs. (2) —
Fuel tank and filter Clean o (2) —
Fuel tube Check Every 2 years (Replace if necessary) (2) —
background
SERVICING YOUR GENERATOR
67
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Place a suitable container below the engine to catch the used oil.
2. Open the maintenance cover to access the oil filler cap.
3. Remove the oil filler cap, oil drain bolt and sealing washer, and drain the oil
into the container.
Improper disposal of engine oil can be harmful to the environment.
If you change your own oil, please dispose of the used oil properly. Put it in a
sealed container, and take it to a recycling center. Do not discard it in a trash bin,
dump it on the ground, or pour it down the drain.
4. Install a new sealing washer and the oil drain bolt, and tighten the bolt
securely.
Torque: 32.5 lbf·ft (44.1 N·m, 4.5 kgf·m)
5. If it is difficult to fill the engine with oil, set the funnel contained in the
generator package to the oil filler port, and pour oil. Refill to the upper limit
mark on the dipstick with the recommended oil (see page 17).
Maximum oil capacity:
Without oil filter replacement: approximately 1.6 US qt (1.5 L)
With oil filter replacement: approximately 1.8 US qt (1.7 L)
background
SERVICING YOUR GENERATOR
68
6. Tighten the oil filler cap securely. Close the maintenance cover.
Wash your hands with soap and water after handling used oil.
AIR CLEANER SERVICE
Foam Air Filter Cleaning
A dirty foam air filter will restrict air flow to the carburetor, reducing engine
performance. If you operate the generator in very dusty areas, clean the foam
air filter more frequently than specified in the Maintenance Schedule.
1. Clean the foam air filter in warm soapy water, rinse, and allow to dry
thoroughly, or clean in non-flammable solvent and allow to dry.
2. Dip the foam air filter in clean engine oil, and then squeeze out all excess oil.
The engine will smoke when started if too much oil is left in the filter.
3. Wipe dirt from the air cleaner housing and cover using a moist rag. Be careful
to prevent dirt from entering the air duct that leads to the carburetor.
OIL FILLER CAP
FUNNEL
SEALING WASHER (Replace)
OIL DRAIN BOLT
Clean Squeeze and Dry
Do not twist.
Dip in Oil
Squeeze
Do not twist.
background
SERVICING YOUR GENERATOR
69
SEDIMENT CUP CLEANING
The sediment cup prevents water that may be in the fuel tank from entering the
carburetor. If the engine has not been run for a long time, the sediment cup
should be cleaned.
1. Turn the engine switch to the OFF
position.
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.
ENGINE SWITCH
ON
OFF
background
SERVICING YOUR GENERATOR
70
2. Turn the fuel valve lever to the OFF
position.
3. Unscrew the sediment cup.
4. Clean the sediment cup in non-flammable or high flash point solvent.
5. Install the sediment cup and a new O-ring.
6. Turn the fuel valve to the ON position and check for leaks.
FUEL VALVE LEVER
OFF
ON
FUEL VALVE LEVER
OFF
O-RING (Replace)
SEDIMENT CUP
background
SERVICING YOUR GENERATOR
71
SPARK PLUG SERVICE
In order to service the spark plug, you will need a spark plug wrench
(commercially available).
Required spark plug: ZFR5F (NGK)
To ensure proper engine operation, the spark plug must be properly gapped
and free of deposits.
An incorrect spark plug can cause engine damage.
If the engine is hot, allow it to cool before servicing the spark plugs.
1. Remove the four 6 mm flange bolts, and remove the cover.
2. Disconnect the spark plug caps, and remove any dirt from around the spark
plugs area.
3. Remove the spark plugs with a spark plug wrench.
COVER
6 mm FLANGE BOLT (4)
SPARK PLUG WRENCH
SPARK PLUG CAP
background
SERVICING YOUR GENERATOR
72
4. Inspect the spark plug. Replace it if the electrodes are worn or fouled, or if the
insulator is cracked or chipped. Clean the spark plug with a wire brush if it is
to be reused.
5. Measure the spark plug electrode gap with a wire-type feeler gauge. Correct
the gap, if necessary, by carefully bending the side electrode.
Spark plug gap:
0.028–0.031 in (0.7–0.8 mm)
6. Make sure that the spark plug sealing washer is in good condition, and thread
the spark plug in by hand to prevent cross-threading.
7. After the spark plug is seated, tighten with a spark plug wrench to compress
the washer.
If reinstalling a used spark plug, tighten 1/8–1/4 turn after the spark plug is
seated.
If installing a new spark plug, tighten 1/2 turn after the spark plug is seated.
Torque: 13.0 lbf·ft (17.7 N·m, 1.8 kgf·m)
A loose spark plug can overheat and damage the engine.
Overtightening the spark plug can damage the threads in the cylinder head.
8. Reinstall the spark plug caps securely.
9. Install the cover in the reverse order of removal.
0.028–0.031 in (0.7–0.8 mm)
SEALING WASHER
SIDE ELECTRODE
INSULATOR
background
SERVICING YOUR GENERATOR
73
SPARK ARRESTER SERVICE
The spark arrester must be serviced every 100 hours to keep it functioning as
designed.
If the engine has been running, the muffler will be very hot. Allow the muffler to
cool before servicing the spark arrester.
1. Remove the four 6 mm flange bolts, and remove the muffler protector.
MUFFLER PROTECTOR
6 mm FLANGE BOLT (4)
background
SERVICING YOUR GENERATOR
74
2. Remove the 4 mm self-tapping screw, and remove the spark arrester.
3. Use a brush to remove carbon deposits from the spark arrester screen.
Be careful to avoid damaging the screen.
The spark arrester must be free of breaks and tears. Replace the spark arrester
if it is damaged.
4. Install the spark arrester in the reverse order of removal.
Torque: 1.6 lbf·ft (2.2 N·m, 0.22 kgf·m)
5. Install the muffler protector in the reverse order of removal.
SPARK ARRESTER
4 mm SELF-TAPPING SCREW
background
SERVICING YOUR GENERATOR
75
BATTERY SERVICE
Your generator’s engine charging system charges the battery while the engine
is running. However, if the generator is only used periodically, the battery must
be charged monthly to maintain the battery service life.
Emergency Procedures
Eyes – Wash your eye(s) with plenty of water avoiding damaging your eye(s)
with water pressure. Call your local Poison Center or a doctor immediately.
Skin – Remove contaminated clothing. Wash the skin with large quantities of
water. Call your local Poison Center or a doctor immediately.
Swallowing – Wash mouth with a large amount of water and drink a cup of
water. Call your local Poison Center or a doctor immediately.
The battery contains sulfuric acid
(electrolyte), which is highly corrosive
and poisonous.
Getting electrolyte in your eyes or on
your skin can cause serious burns.
Wear protective clothing and eye
protection when working near the
battery.
background
SERVICING YOUR GENERATOR
76
The battery gives off explosive
hydrogen gas during normal operation.
A spark or flame can cause the battery to
explode with enough force to kill or
seriously hurt you.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.
background
SERVICING YOUR GENERATOR
77
Battery Inspection
The electrolyte level must be kept between the UPPER and LOWER level marks.
If the electrolyte level is below the LOWER level, sulfation and battery plate
damage will occur.
If rapid loss of electrolyte is experienced, or if your battery seems to be weak
causing slow operation of the starter motor, see your authorized Honda Power
Equipment dealer.
1. Locate the battery. Check the electrolyte level with the generator on a level
surface. Remove the battery cell caps.
2. Inspect the electrolyte level of each cell.
The electrolyte level must be kept between the UPPER and LOWER level
marks, and electrolyte liquid should cover all the plates.
3. If any plates are not covered, remove the battery and add distilled water as
necessary.
UPPER LEVEL
BATTERY CELL CAPS
LOWER LEVEL
BATTERY
background
SERVICING YOUR GENERATOR
78
Battery Removal
WARNING: Battery posts, terminals, and related accessories contain lead and
lead compounds. Wash your hands after handling.
1. Remove the four 6 mm flange bolts,
and remove the cover.
2. Remove the negative (–) cable from
the battery negative (–)
terminal first, and then remove the
positive (+) cable from the battery
positive (+) terminal.
3. Remove the flange nuts, and remove
the battery set plate.
4. Remove the battery from the battery
tray.
This symbol on the battery means that this product must not be
treated as household waste.
An improperly disposed of battery can be harmful to the environment and human
health.
Always confirm local regulations for battery disposal.
COVER
6 mm FLANGE BOLT (4)
NEGATIVE (–) CABLE
BATTERY SET PLATE
FLANGE NUT
POSITIVE (+)
CABLE
BATTERY TRAY
background
SERVICING YOUR GENERATOR
79
Battery Charging
The battery is rated at 28.0 Ah (ampere hours). Charging current should equal
10% of the battery’s ampere hour rating.
Battery: 12 V 28.0 Ah (5 HR)
1. Connect the battery charger following the manufacturer’s instructions.
2. Charge the battery.
3. Clean the outside of the battery and the battery compartment with a solution
of baking soda and water.
Battery Installation
1. Install the battery into the generator.
2. Install the battery set plate and tighten the flange nuts.
3. Connect the battery positive (+) cable to the battery positive (+) terminal first,
and tighten the bolt securely.
4. Slide the battery boot over the positive (+) cable and terminal.
5. Connect the battery negative (–) cable to the battery negative (–) terminal,
and tighten the bolt securely.
6. Install the cover in the reverse order of removal.
background
SERVICING YOUR GENERATOR
80
FUSE
If the fuse is blown, the starter motor won’t operate.
In the event of fuse failure, locate the cause of failure and repair it before you
continue operation. If the fuse continues to fail, discontinue generator use and
consult an authorized Honda Power Equipment dealer.
1. Turn the engine switch to the OFF position and remove the key before
checking or replacing the fuse.
4. Install the fuse holder cover in the reverse order of removal.
BLOWN FUSE
20 A FUSE
5 A FUSE
FUSE HOLDER COVER
2. Remove the fuse holder cover
and pull the fuse out.
3. Replace the fuse with a fuse of
the same type and rating.
Specified fuse: 5 A, 20 A
Never use a fuse with a different
rating from that specified. Serious
damage to the electrical system or
fire may result.
background
81
STORAGE
STORAGE PREPARATION
Proper storage preparation is essential for keeping your generator trouble-free
and looking good. The following steps will help to keep rust and corrosion from
impairing your generator’s function and appearance, and will make the engine
easier to start when you use the generator again.
Cleaning
Wipe the generator with a moist cloth. After the generator has dried, touch up
any damaged paint, and coat other areas that may rust with a light film of oil.
Fuel
Depending on the region where you operate your equipment, fuel formulations may
deteriorate and oxidize rapidly. Fuel deterioration and oxidation can occur in as
little as 30 days and may cause damage to the carburetor and/or fuel system. Please
check with your servicing dealer for local storage recommendations.
Gasoline will oxidize and deteriorate in storage. Old gasoline will cause hard
starting, and it leaves gum deposits that clog the fuel system. If the gasoline in
your generator deteriorates during storage, you may need to have the
carburetor and other fuel system components serviced or replaced.
The length of time that gasoline can be left in your fuel tank and carburetor
without causing functional problems will vary with such factors as gasoline
blend, your storage temperatures, and whether the fuel tank is partly or
completely filled. The air in a partly filled fuel tank promotes fuel deterioration.
Very warm storage temperatures accelerate fuel deterioration. Fuel
deterioration problems may occur within a few months, or even less if the
gasoline was not fresh when you filled the fuel tank.
The Distributor’s Limited Warranty does not cover fuel system damage or engine
performance problems resulting from neglected storage preparation.
You can extend fuel storage life by adding a gasoline stabilizer that is
formulated for that purpose, or you can avoid fuel deterioration problems by
draining the carburetor, sediment cup, and/or fuel tank.
background
STORAGE
82
Service according to the table below:
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month No preparation required
1 to 2 months Fill with fresh gasoline and add gasoline stabilizer*.
2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer*.
Drain the carburetor float bowl (see page 83).
Drain the fuel sediment cup (see page 69).
1 year or more Fill with fresh gasoline and add gasoline stabilizer*.
Drain the carburetor float bowl (see page 83).
Drain the fuel sediment cup (see page 69).
Remove the spark plug. Put a teaspoon of engine
oil into each cylinder. Turn the engine for a few
seconds by turning the engine switch to the START
position to distribute the oil in the cylinders.
Reinstall the spark plug.
Change the engine oil (see page 67).
After removal from storage, drain the stored
gasoline into a suitable container, and fill with
fresh gasoline before starting.
* Use gasoline stabilizers that are formulated to extend storage life. Follow the
manufacturer’s instructions for use.
Contact your authorized Honda Power Equipment dealer for stabilizer
recommendations.
background
STORAGE
83
DRAINING THE FUEL TANK AND CARBURETOR
1. Unscrew the fuel tank cap, remove the fuel strainer, and empty the fuel tank
into an approved gasoline container. We recommend using a commercially
available gasoline hand pump to empty the tank. Do not use an electric
pump. Reinstall the fuel strainer and the fuel tank cap.
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.
background
STORAGE
84
2. Pull out the carburetor drain tube end under the fan cover of the engine, and
place it in a suitable container.
3. Remove the air cleaner cover (see page 44).
4. Loosen the carburetor drain screw.
If the drain screw is difficult to loosen, wrap duct tape around the screwdriver
stem until the diameter becomes 8 mm as illustrated. By doing so, the
screwdriver is easily inserted into the cutout portion of the drain bolt, and
you can loosen the drain bolt easily.
5. Drain the gasoline from the carburetor into the container.
6. Tighten the carburetor drain screw securely.
7. Install the air cleaner cover (see page 44).
CARBURETOR DRAIN SCREW
DUCT TAPE
CARBURETOR DRAIN TUBE
background
STORAGE
85
Engine Oil
Change the engine oil (see page 67).
Engine Cylinder
1. Remove the spark plugs (see page 71).
2. Pour a teaspoon (5 cc) of clean engine oil into each cylinder.
3. Turn the engine for a few seconds by turning the engine switch to the START
position to distribute the oil in the cylinders.
4. Reinstall the spark plugs (see page 72).
5. Remove the battery and store it in a cool, dry place. Recharge it once a
month.
6. Cover the generator to keep out dust.
background
STORAGE
86
STORAGE PRECAUTIONS
If your generator will be stored with gasoline in the fuel tank and carburetor, it is
important to reduce the hazard of gasoline vapor ignition.
Select a well ventilated storage area away from any appliance that operates with
a flame, such as a furnace, water heater, or clothes dryer.
Also avoid any area with a spark-producing electric motor, or where power tools
are operated.
If possible, avoid storage areas with high humidity, because that promotes rust
and corrosion.
Unless all fuel has been drained from the fuel tank, leave the fuel valve in the
OFF position to reduce the possibility of leakage.
Place the generator on a level surface. Tilting can cause fuel or oil leakage.
With the engine and exhaust system cool, cover the generator to keep out dust.
A hot engine and exhaust system can ignite or melt some materials.
Do not use a plastic sheet as a dust cover. A nonporous cover will trap moisture
around the generator, promoting rust and corrosion.
REMOVAL FROM STORAGE
Check your generator as described in the "BEFORE OPERATION" chapter of this
manual (see page 40).
If the generator was stored for 1 year or longer, drain the fuel tank (see page 83)
and refuel with fresh gasoline. If you keep a container of gasoline for refueling,
be sure that it contains only fresh gasoline. Gasoline oxidizes and deteriorates
over time, causing hard starting.
If the cylinder was coated with oil during storage preparation, the engine may
smoke briefly at startup. This is normal.
background
87
TRANSPORTING
To prevent spillage when transporting, the generator should be secured upright
in its normal operating position, with the fuel valve OFF.
Do not lay the generator on its side when moving, storing, or operating it. Oil or fuel
may leak and damage the engine or your property.
Do not operate the generator while it is being transported or while it is
mounted to any type of vehicle, trailer, or boat.
Take care not to drop or strike the generator when transporting. Do not place
heavy objects on the generator.
When using ropes or tie-down straps to secure the generator for transportation,
be sure to only use the frame bars as attachment points. Do not fasten ropes or
straps to any portions of the generator body or handle bar.
An engine that has been running will
remain very hot for a period of time.
A hot engine and exhaust system can
burn you and ignite some material.
If the generator has been used, allow it
to cool for at least 15 minutes before
loading the generator on the transport
vehicle.
background
TRANSPORTING
88
To lift the generator
Lift the generator by the lifting hanger. Do not try to lift the generator by and
other part.
background
89
TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE WILL NOT START
Possible Cause Correction
Fuel valve lever OFF. Turn lever ON (see page 48).
Engine switch OFF. Turn engine switch to ON
(see page 49).
Choke OPEN. Move to CLOSED unless engine is
warm.
Out of fuel. Refuel (see page 19).
Bad fuel; generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank and carburetor
(see page 83).
Refuel with fresh gasoline
(see page 19).
Low oil level caused Oil Alert to stop
engine.
Add oil (see page 17).
Turn engine switch to OFF and then
restart the engine.
Spark plug faulty, fouled, or
improperly gapped.
Gap or replace spark plug
(see page 71).
Spark plug wet with fuel
(flooded engine).
Dry and reinstall spark plug.
Fuel strainer restricted, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
CO-MINDER (CO Shut-off System) is
detecting high carbon monoxide (CO)
levels around the generator.
Review the location of the generator,
and place it in a well-ventilated
outdoor location (see page 25).
When the engine is stopped
automatically by CO-MINDER, press
the CO-MINDER reset button to restart
the engine (see page 52).
background
TAKING CARE OF UNEXPECTED PROBLEMS
90
ENGINE LACKS POWER
NO POWER AT THE AC RECEPTACLES
Possible Cause Correction
Air filter restricted. Clean or replace air filter
(see pages 44, 68).
Bad fuel; generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank and carburetor
(see page 83).
Refuel with fresh gasoline
(see page 19).
Fuel strainer restricted, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
Possible Cause Correction
AC circuit breaker left in the OFF
position after starting.
Check AC load and reset AC
circuit breaker (see page 59).
GFCI system activated.
•GFCI system ①:
Test GFCI and reset AC circuit
breaker (see page 54).
•GFCI system ②:
Test GFCI and press the GFCI RESET
button (see page 56).
• Replace or repair power tool or
appliance.
AC circuit protector tripped. Check AC load and reset circuit
protector (see page 27).
Faulty power tool or appliance. Replace or repair power tool or
appliance.
Stop and restart the engine.
Faulty generator. Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
background
TAKING CARE OF UNEXPECTED PROBLEMS
91
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE
ENGINE
Possible Cause Correction
CO concentration around the
generator is high.
Review the location of the generator,
and place it in a well-ventilated
outdoor location (see page 25).
When the engine is stopped
automatically by CO-MINDER, press
the CO-MINDER reset button to restart
the engine (see page 52).
Possible Cause Correction
CO sensor malfunction. If the engine cannot be started and the
CO ALARM indicator flashes, even if the
location of the generator has changed,
there may be a CO-MINDER
malfunction. Consult an authorized
Honda Power Equipment dealer.
CO sensor may have reached the end
of its useful lifespan (see page 26).
Consult an authorized Honda Power
Equipment dealer.
Possible Cause Correction
CO sensor may reach the end of its
useful lifespan (see page 26).
Consult an authorized Honda Power
Equipment dealer for replacement.
background
92
TECHNICAL INFORMATION
SERIAL NUMBER LOCATION
Record the engine and frame serial numbers and date purchased in the spaces
below. You will need this serial number when ordering parts, and when making
technical or warranty inquiries.
Engine serial number:
Frame serial number:
Date purchased:
FRAME SERIAL NUMBER
ENGINE SERIAL NUMBER
background
TECHNICAL INFORMATION
93
CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION
At high altitude, the standard carburetor air-fuel mixture will be too rich.
Performance will decrease, and fuel consumption will increase. A very rich
mixture will also foul the spark plug and cause hard starting. Operation at an
altitude that differs from that at which this engine was certified, for extended
periods of time, may increase emissions.
High altitude performance can be improved by specific modifications to the
carburetor. If you always operate your generator at altitudes above 2,000 feet
(610 meters), have your authorized Honda servicing dealer perform this
carburetor modification. This engine, when operated at high altitude with the
carburetor modifications for high altitude use, will meet each emission standard
throughout its useful life.
Even with carburetor modification, engine horsepower will decrease about
3.5% for each 1,000-foot (300-meter) increase in altitude. The effect of altitude
on horsepower will be greater than this if no carburetor modification is made.
When the carburetor has been modified for high altitude operation, the air/fuel
mixture will be too lean for low altitude use. Operation at altitudes below 2,000 feet
(610 meters) with a modified carburetor may cause the engine to overheat and
result in serious engine damage. For use at low altitudes, have your servicing dealer
return the carburetor to original factory specifications.
background
TECHNICAL INFORMATION
94
EMISSION CONTROL SYSTEM INFORMATION
Source of Emissions
The combustion process produces carbon monoxide, oxides of nitrogen, and
hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very
important because, under certain conditions, they react to form photochemical
smog when subjected to sunlight. Carbon monoxide does not react in the same
way, but it is toxic.
Honda utilizes appropriate air/fuel ratios and other emissions control systems to
reduce the emissions of carbon monoxide, oxides of nitrogen, and
hydrocarbons.
Additionally, Honda fuel systems utilize components and control technologies
to reduce evaporative emissions.
The U.S. and California Clean Air Acts, and Environment and Climate
Change Canada (ECCC)
U.S. EPA, California and Canadian regulations require all manufacturers to
furnish written instructions describing the operation and maintenance of
emission control systems.
The following instructions and procedures must be followed in order to keep
the emissions from your Honda engine within the emission standards.
Tampering and Altering
Tampering is a violation of federal and California law.
Tampering with or altering the emission control system may increase emissions
beyond the legal limit. Among those acts that constitute tampering are:
• Removal or alteration of any part of intake, fuel, or exhaust systems.
• Alterations that would cause the engine to operate outside its design
parameters.
background
TECHNICAL INFORMATION
95
Problems That May Affect Emissions
If you are aware of any of the following symptoms, have your engine inspected
and repaired by your authorized Honda Power Equipment dealer.
• Hard starting or stalling after starting.
•Rough idle.
• Misfiring or backfiring under load.
• Afterburning (backfiring).
• Black exhaust smoke or high fuel consumption.
Replacement Parts
The emissions control systems on your new Honda engine were designed, built,
and certified to conform with EPA, California (models certified for sale in
California only), and Canadian emissions regulations. We recommend the use of
Honda Genuine parts whenever you have maintenance done. These original
design replacement parts are manufactured to the same standards as the
original parts, so you can be confident of their performance. Honda cannot
deny coverage under the emission warranty solely for the use of non-Honda
replacement parts or service performed at a location other than an authorized
Honda dealership; you may use comparable EPA certified parts, and have
service performed at non-Honda locations. However, the use of replacement
parts that are not of the original design and quality may impair the effectiveness
of your emissions control system.
A manufacturer of an aftermarket part assumes the responsibility that the part
will not adversely affect emissions performance. The manufacturer or rebuilder
of the part must certify that use of the part will not result in a failure of the
engine to comply with emissions regulations.
Maintenance
As the power equipment engine owner, you are responsible for completing all
required maintenance listed in your owner's manual. Honda recommends that
you retain all receipts covering maintenance on your power equipment engine,
but Honda cannot deny warranty coverage solely for the lack of receipts or for
your failure to ensure that all scheduled maintenance has been completed.
Follow the "MAINTENANCE SCHEDULE" on page 66.
Remember that this schedule is based on the assumption that your Honda
engine product will be used for its designed purpose. Sustained high-load or
high-temperature operation, or use in dusty conditions, will require more
frequent service.
background
TECHNICAL INFORMATION
96
Air Index
(Models certified for sale in California)
An Air Index Information label is applied to engines certified to an emission
durability time period in accordance with the requirements of the California Air
Resources Board.
The bar graph is intended to provide you, our customer, the ability to compare
the emissions performance of available engines. The lower the Air Index, the
less pollution.
The durability description is intended to provide you with information relating
to the engine’s emission durability period. The descriptive term indicates the
useful life period for the engine’s emission control system. See your "Emission
Control System Warranty" (see page 107) for additional information.
Descriptive Term Applicable to Emission Durability Period
Moderate 50 hours (0–80 cc, inclusive)
125 hours (greater than 80 cc)
Intermediate 125 hours (0–80 cc, inclusive)
250 hours (greater than 80 cc)
Extended 300 hours (0–80 cc, inclusive)
500 hours (greater than 80 cc)
1,000 hours (225 cc and greater)
background
TECHNICAL INFORMATION
97
SPECIFICATIONS
Dimensions
Engine
Generator
Model EB10000
Type AG AN
Description code EBVC
Length
[Handle in up position]
41.0 in (1,041 mm)
[55.9 in (1,420 mm)]
Width 27.7 in (703 mm)
Height 35.1 in (891 mm)
Dry mass [weight] 402.8 lbs (182.7 kg)
Model GX630H
Engine type 4-stroke, overhead valve, 2 cylinder
Displacement
42.0 cu-in (688 cm
3
)
Bore×Stroke 3.07×2.83 in (78.0×72.0 mm)
Compression ratio 9.3:1
Engine speed 3,600 rpm
Cooling system Forced air
Ignition system CDI magneto ignition
Oil capacity Without oil filter replacement:
approximately 1.6 US qt (1.5 L)
With oil filter replacement:
approximately 1.8 US qt (1.7 L)
Fuel tank capacity 8.19 US gal (31.0 L)
Spark plug ZFR5F (NGK)
Model EB10000
Type AG AN
AC output Rated frequency 60 Hz
Rated voltage 120 V / 240 V
Rated ampere 37.5 A×2 / 37.5 A
Rated output 9.0 kVA
Maximum output 10.0 kVA
background
TECHNICAL INFORMATION
98
Tuneup Specifications
ITEM SPECIFICATION MAINTENANCE
Spark plug gap 0.028–0.031 in
(0.7–0.8 mm)
Refer to page: 72
Valve clearance (cold) IN: 0.08±0.02 mm
EX: 0.10±0.02 mm
See your authorized
Honda dealer
Other specifications No other adjustments needed.
background
TECHNICAL INFORMATION
99
WIRING DIAGRAM
background
100
CONSUMER INFORMATION
DEALER LOCATOR INFORMATION
To find an authorized Honda Servicing Dealer anywhere in the United States:
Visit our web site:
http://powerequipment.honda.com/dealer-locator
Honda PUBLICATIONS
Shop Manual
This manual covers complete maintenance and overhaul procedures.
It is intended to be used by a skilled technician.
Available through your Honda dealer or visit
http://powerequipment.honda.com/support/shop-manuals
Parts Catalog
This manual provides complete, illustrated parts lists for your generator. Visit
peparts.honda.com for free online access to the parts catalog. It is also available
for purchase in paper form through your Honda dealer.
Accessories Catalog
Your authorized Honda Power Equipment dealer offers a wide selection of
accessories (optional equipment) to make your generator even more useful.
Visit http://powerequipment.honda.com/generators/accessories and click on
See all generator accessories and Welders to see the entire catalog of
accessories.
background
CONSUMER INFORMATION
101
CUSTOMER SERVICE INFORMATION
Honda Power Equipment dealership personnel are trained professionals. They
should be able to answer any question you may have. If you encounter a
problem that your dealer does not solve to your satisfaction, please discuss it
with the dealership’s management.
The Service Manager or General Manager can help. Almost all problems are
solved in this way.
If you are dissatisfied with the decision made by the dealership’s management,
contact the Honda Power Equipment Customer Relations Office. You can write
to:
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Or telephone: (770) 497-6400 M-F 9:00am - 7:30pm ET
When you write or call, please give us this information:
• Model and serial numbers (see page 92)
• Name of the dealer who sold the generator to you
• Name and address of the dealer who services your generator
• Date of purchase
• Your name, address, and telephone number
• A detailed description of the problem
background
CONSUMER INFORMATION
102
Distributor’s Limited Warranty
This warranty is limited to the following Honda products when distributed by
American Honda Motor Co., Inc., Power Sports and Products Division, 4900
Marconi Drive, Alpharetta, Georgia 30005. The following warranty applies to
products manufactured on or after April 1, 2023.
(1) Length of Warranty: Batteries supplied with applicable products as
standard, original equipment are covered by this warranty for a period of 12
months (private residential) or 3 months (commercial/rental/institutional
use) from the date of original retail product purchase.
(2) Private residential: Used in maintaining owner’s primary and/or secondary
residence. Any other use, including but not limited to informal “for hire” use,
is considered commercial/rental/institutional use.
To Qualify for This Warranty:
The product must be purchased in the United States, Puerto Rico, or the U.S.
Virgin Islands from American Honda or a dealer authorized by American Honda
to sell those products. This warranty applies to first retail purchaser and each
subsequent owner during the applicable warranty time period, unless noted
otherwise.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any part that is proven to be
defective in material or workmanship under normal use during the applicable
warranty time period. Warranty repairs and replacements will be made without
charge for parts or labor. Anything replaced under warranty becomes the
property of American Honda Motor Co., Inc. All parts replaced under warranty
will be considered as part of the original product, and any warranty on those
parts will expire coincident with the original product warranty.
PRODUCTS COVERED
BY THIS WARRANTY:
LENGTH OF WARRANTY: (1)
(FROM DATE OF ORIGINAL RETAIL PURCHASE)
PRIVATE
RESIDENTIAL (2)
COMMERCIAL/
RENTAL/INSTITUTIONAL
Generators 36 months 12 months
The Parts, Accessories, and Apparel warranty is on page 105
background
CONSUMER INFORMATION
103
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment product,
accessory, replacement part, apparel, or the power equipment on which the
accessory or replacement part is installed, and proof of purchase to any Honda
Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin
Islands who is authorized to sell and/or service that product, during the dealer’s
normal business hours. To locate a dealer near you, visit our web site at http://
powerequipment.honda.com and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved;
normally this will resolve the problem. However, if you should require further
assistance, write or call the Power Equipment Customer Relations Department
of American Honda Motor Co., Inc. at the following address:
American Honda Motor Co., Inc.
Power Equipment Customer Relations Dept.
4900 Marconi Drive
Alpharetta, GA 30005-8847 Telephone: (770) 497-6400
background
CONSUMER INFORMATION
104
Exclusions:
1. Any damage or deterioration resulting from the following:
– Neglect of the periodic maintenance as specified in the product owner’s
manual
– Improper repair or maintenance
– Operating methods other than those indicated in the product owner’s
manual
– Increasing engine speed beyond factory specification
– The use of non-genuine Honda parts, accessories, lubricants, and fluids
other than those approved by Honda
– Exposure of the product to soot and smoke, chemical agents, bird
droppings, sea water, salt, or other corrosive environments
– Collision, fuel contamination or deterioration, neglect, unauthorized
alteration, misuse, incorporation or use of unsuitable attachments or parts
– Normal wear and tear (including, but not limited to, normal fading of
painted or plated surfaces, sheet peeling, and other natural deterioration)
2. Consumable parts: Honda does not warrant parts deterioration due to
normal wear and tear. The following parts are not covered by this warranty
unless they are needed during another repair covered under this warranty:
spark plug, fuel filter, air cleaner element, clutch disc, tire, wheel bearing,
recoil starter rope, cable, belt, cutter blade, oil, and grease.
3. Cleaning, adjustment, and normal periodic maintenance work (carburetor
cleaning, engine oil draining, blade sharpening, belt and cable adjustments).
4. Any product that has ever been declared a total loss or sold for salvage by a
financial institution or insurer.
5. Auger and paddle assemblies, skid shoes, and scraper bars of snow throwers/
snow blowers, tiller tines of roto-tillers, and mower blades and mower deck
housings are specifically not warranted against impact damage including,
but not limited to, abrasive damage.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the
product, transportation, commercial loss, or any other incidental or
consequential damage. Any implied warranties are limited to the duration of
this written limited warranty. Some states do not allow limitations on how long
an implied warranty lasts and/or do not allow the exclusion or limitation of
incidental or consequential damages, therefore the above exclusions and
limitations may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights, which vary from state to state.
background
CONSUMER INFORMATION
105
Honda Parts, Accessories, and Apparel
This warranty is limited to Honda Power Equipment parts, accessories, and
apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi
Drive, Alpharetta, Georgia 30005-8847.
To Qualify for This Warranty:
1. The parts, accessories, or apparel must be purchased from American Honda
or a dealer authorized by American Honda to sell those products in the
United States, Puerto Rico, and the U.S. Virgin Islands. Parts and accessories
must be purchased for installation on original Honda equipment or engines
to be eligible for warranty coverage.
Installing parts and accessories on non-Honda products or engines voids this
warranty.
2. You must be the first retail purchaser. This warranty is not transferable to
subsequent owners.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any Honda Power
Equipment parts, accessories, or apparel that are proven to be defective in
material or workmanship under normal use during the applicable warranty time
period. Anything replaced under warranty becomes the property of American
Honda Motor Co., Inc. The warranty on all parts, accessories, and apparel
replaced under warranty will expire coincident with the original warranty on the
replaced parts, accessories, or apparel.
Parts and accessories installed by a dealer who is authorized by American
Honda to sell them will be repaired or replaced under warranty without charge
for parts or labor. If installed by anyone else, parts and accessories will be
repaired or replaced under warranty without charge for parts, but any labor
charges will be the responsibility of the purchaser.
Apparel will be repaired or replaced under warranty without any charge.
PRODUCTS COVERED
BY WARRANTY:
LENGTH OF WARRANTY:
(FROM DATE OF ORIGINAL RETAIL PURCHASE)
PRIVATE
RESIDENTIAL
COMMERCIAL/
RENTAL/INSTITUTIONAL
Parts 6 months 3 months
Batteries 6 months 3 months
Accessories 12 months 3 months
Apparel 6 months 3 months
background
CONSUMER INFORMATION
106
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment part, accessory, or
apparel, or the Honda Power Equipment on which the accessory or part is
installed, and proof of purchase to any Honda Power Equipment dealer in the
United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell
that product, during the dealer’s normal business hours.
To locate a dealer near you, go to our web site at http://PowerEquipment.Honda.com
and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved; normally this
will resolve the problem. However, if you should require further assistance,
write or call the Power Equipment Customer Relations Department of American
Honda Motor Co., Inc. Refer to page 103 for contact information.
Exclusions:
This warranty does not extend to parts, accessories, or apparel affected or
damaged by collision, normal wear, use in an application for which the product
was not designed, or any other misuse, neglect, incorporation or use of
unsuitable attachments or parts, unauthorized alteration, improper installation,
or any causes other than defects in material or workmanship of the product.
Installing parts and accessories on non-Honda products or engines voids this
warranty.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the
product, or the power equipment on which the product is installed,
transportation, commercial loss, or any other incidental or consequential
damage. Any implied warranties are limited to the duration of this written
warranty. Some states do not allow limitations on how long an implied warranty
lasts and/or do not allow the exclusion or limitation of incidental or
consequential damages, so the above exclusions and limitations may not apply
to you.
This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state.
background
CONSUMER INFORMATION
107
Emission Control System Warranty
Your new Honda Power Equipment engine complies with the U.S. EPA,
Environment Canada, and State of California (models certified for sale in
California only) emission regulations. American Honda Motor Co., Inc. provides
the emission warranty coverage for engines in the United States and its
territories. Honda Canada Inc. provides the emission warranty for engines in the
13 provinces and territories of Canada. In the remainder of this Emission Control
System Warranty, American Honda Motor Co., Inc. and Honda Canada Inc. will
be referred to as Honda.
CALIFORNIA EXHAUST AND EVAPORATIVE EMISSIONS CONTROL
WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS
The California Air Resources Board and Honda are pleased to explain the
exhaust and evaporative emissions (“emissions”) control system warranty on
your 2024 and later Honda Power Equipment engine. In California, new
equipment that use small off-road engines must be designed, built, and
equipped to meet the State's stringent anti-smog standards. Honda must
warrant the emissions control system on your power equipment engine for the
periods of time listed below provided there has been no abuse, neglect, or
improper maintenance of your small off-road engine or equipment leading to
the failure of the emissions control system.
Your emissions control system may include parts such as the carburetor or
fuel-injection system, the ignition system, catalytic converter, fuel tanks, fuel
lines (for liquid fuel and fuel vapors), fuel caps, valves, canisters, filters, clamps
and other associated components. Also included may be hoses, belts,
connectors, and other emission-related assemblies (see page 111 for additional
covered parts).
Where a warrantable condition exists, Honda will repair your power equipment
engine at no cost to you including diagnosis, parts and labor.
MANUFACTURER'S WARRANTY COVERAGE:
The exhaust and evaporative emissions control system on your Honda power
equipment engine is warranted for two years. If any emissions-related part on
your Honda power equipment engine is defective, the part will be repaired or
replaced by Honda.
background
CONSUMER INFORMATION
108
OWNER'S WARRANTY RESPONSIBILITY:
• As the power equipment engine owner, you are responsible for the
performance of the required maintenance listed in your owner's manual.
Honda recommends that you retain all receipts covering maintenance on
your power equipment engine, but Honda cannot deny warranty coverage
solely for the lack of receipts or for your failure to ensure the performance of
all scheduled maintenance.
• As the power equipment engine owner, you should however be aware that
Honda may deny you warranty coverage if your power equipment engine or a
part has failed due to abuse, neglect, improper maintenance, or unapproved
modifications.
• You are responsible for presenting your power equipment engine to a Honda
Power Equipment servicing dealer as soon as the problem exists. The
warranty repairs shall be completed in a reasonable amount of time, not to
exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities,
you should contact the Honda office in your region:
American Honda Motor Co., Inc.
Power Equipment Customer
Relations
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
@ahm.honda.com
or
Honda Canada Inc.
Power Equipment Customer
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
Telephone: (888) 946-6329
background
CONSUMER INFORMATION
109
YOUR WARRANTY RIGHTS AND OBLIGATIONS
Other States, U.S. territories, and Canada:
In other areas of the United States and in Canada, your engine must be
designed, built, and equipped to meet the U.S. EPA and Environment Canada
emission standards for spark-ignited engines at or below 19 kilowatts.
Specific Honda products that do not meet the California emissions regulations
can be identified by a “California: Not for sale or use” or “California: Only for use
in Farming or Construction Equipment” decal.
All of the United States and Canada:
The exhaust and evaporative emissions control system on your Honda power
equipment engine sold in the United States and Canada is warranted for two
years from the date of delivery to the ultimate purchaser or the length of the
Honda Distributor’s Limited Warranty, whichever is longer. This warranty is
transferable to each subsequent purchaser for the duration of the warranty
period.
If any emissions-related part on your Honda power equipment engine is
defective, the part will be repaired or replaced by Honda. All defective parts
replaced under this warranty become the property of Honda. Only Honda
approved replacement parts may be used in the performance of any warranty
repairs and must be provided without charge to the owner. A list of warranted
parts is on the reverse side of this warranty statement. All emission related parts
are under warranty for the remainder of the warranty period. Normal
maintenance items, such as spark plugs and filters, that are on the warranted
parts list are warranted up to their required replacement interval only.
Honda will also replace other engine components damaged by a failure of any
warranted part during the warranty period. Honda cannot deny coverage under
the emission warranty solely for use of non-Honda replacement parts or service
performed at a location other than an authorized Honda dealership; however,
use of a part that is not functionally identical to the original equipment part in
any respect that may in any way affect emissions (including durability) could
result in denial of coverage. If such a non-Honda replacement part is used in the
repair or maintenance of your engine, and an authorized Honda dealer
determines it is defective or causes a failure of a warranted part, your claim for
repair of your engine may be denied. If the part in question is not related to the
reason your engine requires repair, your claim will not be denied.
background
CONSUMER INFORMATION
110
TO OBTAIN WARRANTY SERVICE:
You must, at your own expense, take your Honda Power Equipment engine or
the product on which it is installed, along with your sales registration card or
other proof of original purchase date, to any Honda Power Equipment dealer
who is authorized by Honda to sell and service that Honda product during their
normal business hours. Claims for repair or adjustment found to be caused
solely by defects in material or workmanship will not be denied because the
engine was not properly maintained and used.
If you are unable to obtain emission warranty service or are dissatisfied with the
warranty service you received, contact the owner of the dealership involved.
Normally this should resolve your problem. However, if you require further
assistance, contact the Honda office in your region:
EXCLUSIONS:
Failures other than those resulting from defects in material or workmanship are
not covered by this warranty. This warranty does not extend to emission control
systems or parts that are affected or damaged by owner abuse, neglect,
improper maintenance, or unapproved modifications.
This warranty does not cover replacement of expendable maintenance items
made in connection with required maintenance service after the item's first
scheduled replacement as listed in the maintenance section of the product
owner's manual, such as: spark plugs and filters.
American Honda Motor Co., Inc.
Power Equipment Customer
Relations
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
@ahm.honda.com
or
Honda Canada Inc.
Power Equipment Customer
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
Telephone: (888) 946-6329
background
CONSUMER INFORMATION
111
DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION OF IMPLIED
WARRANTIES:
American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any
responsibility for incidental or consequential damages such as loss of time or
the use of the power equipment, or any commercial loss due to the failure of the
equipment; and any implied warranties are limited to the duration of this
written warranty. This warranty is applicable only where the California, U.S. EPA,
or Environment Canada emission control system warranty regulation is in effect.
EMISSION CONTROL SYSTEM WARRANTY PARTS:
*Covered up to the first required replacement only.
See the "MAINTENANCE SCHEDULE" on page 66.
SYSTEMS COVERED
BY THIS WARRANTY:
PARTS
DESCRIPTION:
Fuel Metering Carburetor assembly (includes starting enrichment
system), Oxygen sensor, Throttle body, Engine
temperature sensor, Engine control module, Fuel
injector, Fuel regulator, Intake manifold
Evaporative Fuel tank, Fuel cap, Fuel lines (for liquid and fuel
vapors), Carbon canister, Canister mounting
brackets, Fuel line fittings, Fuel strainer, Fuel valve,
Fuel pump, Fuel hose joint, Canister purge port
connector, Evaporative emission canister purge
valve
Exhaust Catalyst, Exhaust pipe, Muffler (with catalyst),
Exhaust manifold
Air Induction Air cleaner case, Air cleaner element*
Ignition Flywheel comp., Flywheel magneto, Ignition pulse
generator, Crankshaft position sensor, Power coil,
Ignition coil assembly, Ignition control module,
Spark plug cap, Spark plug*
Crankcase Emission
Control
Crankcase breather tube, Breather valve assembly,
Oil filler cap
Miscellaneous Parts Tubing, fittings, seals, gaskets, and clamps
associated with these listed systems.
background
CONSUMER INFORMATION
112
REGISTRATION
Please Register Your Generator
If your dealer did not collect registration information from you, please take a
few minutes and register your purchase with Honda. This allows us to contact
you with any important updates regarding your generator. Please note
registration is not required to obtain warranty service. You can register your
generator by visiting the Honda Power Equipment website,
http://powerequipment.honda.com/support and click on Product Registration.
Your information will remain confidential. It will not be released to any other
company or organization.
background
113
INDEX
A
AC Appliance and Power Cord........................................................................................ 42
AC Applications.................................................................................................................... 60
AC Circuit Breaker................................................................................................................ 28
AC Circuit Protectors .......................................................................................................... 27
AC OPERATION ..................................................................................................................... 59
AIR CLEANER SERVICE ........................................................................................................ 68
AIR FILTER CHECK ................................................................................................................ 44
Air Index .................................................................................................................................. 96
ARE YOU READY TO GET STARTED? .............................................................................. 40
ASSEMBLY........................................................................................................................ 12, 13
Auto Throttle® System ....................................................................................................... 31
AUTO THROTTLE® SYSTEM ............................................................................................... 61
B
Battery Charging.................................................................................................................. 79
Battery Inspection ............................................................................................................... 77
Battery Installation .............................................................................................................. 79
Battery Removal ................................................................................................................... 78
BATTERY SERVICE................................................................................................................. 75
BEFORE OPERATION ........................................................................................................... 40
C
Carbon Monoxide Hazards................................................................................................. 8
CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION...................... 93
Check the Battery................................................................................................................. 41
Check the Engine................................................................................................................. 41
Check the GFCI...................................................................................................................... 41
Choke Knob............................................................................................................................ 24
Cleaning .................................................................................................................................. 81
CO-MINDER (CO Shut-off System) ................................................................................. 25
COMPONENT & CONTROL LOCATIONS ....................................................................... 22
Connections to a Building’s Electrical System........................................................... 62
CONSUMER INFORMATION........................................................................................... 100
CONTROLS & FEATURES .................................................................................................... 22
CONTROLS.............................................................................................................................. 24
CUSTOMER SERVICE INFORMATION .......................................................................... 101
D
DEALER LOCATOR INFORMATION.............................................................................. 100
Distributor’s Limited Warranty .................................................................................... 102
background
114
INDEX
E
Electric Shock Hazards ......................................................................................................... 9
Emergency Procedures...................................................................................................... 75
EMISSION CONTROL SYSTEM INFORMATION............................................................ 94
Emission Control System Warranty ............................................................................107
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR
FLASHING .......................................................................................................................... 91
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING................................................................................................... 91
Engine Cylinder .................................................................................................................... 85
ENGINE LACKS POWER....................................................................................................... 90
ENGINE OIL CHANGE .......................................................................................................... 67
ENGINE OIL LEVEL CHECK ................................................................................................. 43
ENGINE OIL RECOMMENDATIONS................................................................................. 18
ENGINE OIL...................................................................................................................... 17, 85
Engine Switch........................................................................................................................ 24
ENGINE WILL NOT START .................................................................................................. 89
F
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING
THE ENGINE....................................................................................................................... 91
FEATURES ............................................................................................................................... 33
Fire and Burn Hazards .......................................................................................................... 9
Foam Air Filter Cleaning.................................................................................................... 68
Folding Handle ..................................................................................................................... 32
Fuel Gauge ............................................................................................................................. 39
FUEL RECOMMENDATIONS.............................................................................................. 21
Fuel Valve Lever ................................................................................................................... 24
FUEL.................................................................................................................................. 19, 81
FUSE.......................................................................................................................................... 80
G
GENERATOR SAFETY............................................................................................................. 7
GFCI OPERATION CHECK................................................................................................... 53
GFCI System ①
(120V-30A, 120V/240V-30A, 120V/240V-37.5A Receptacles)............................... 54
GFCI System ②
(120V-20A Duplex Receptacle) ....................................................................................... 56
Ground Fault Circuit Interrupter (GFCI) ....................................................................... 29
Ground Terminal.................................................................................................................. 38
background
115
INDEX
H
Handle Installation .............................................................................................................. 14
Hanger Kit Installation ....................................................................................................... 16
Honda PUBLICATIONS..................................................................................................... 100
HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)
............................................................................................................................................... 52
I
i-Monitor ................................................................................................................................. 34
IMPORTANT SAFETY INFORMATION............................................................................... 7
INITIAL USE INSTRUCTIONS.............................................................................................. 17
INTRODUCTION ......................................................................................................................1
IS YOUR GENERATOR READY TO GO?........................................................................... 40
K
Knowledge ............................................................................................................................. 40
L
Loose Parts ............................................................................................................................. 13
M
MAINTENANCE SAFETY ..................................................................................................... 65
MAINTENANCE SCHEDULE............................................................................................... 66
N
NO POWER AT THE AC RECEPTACLES .......................................................................... 90
O
Oil Alert® System.................................................................................................................. 33
OPERATION ............................................................................................................................ 47
Operator Responsibility....................................................................................................... 7
Q
QUICK REFERENCE INFORMATION .................................................. inside back cover
R
Refuel With Care................................................................................................................... 10
REGISTRATION ................................................................................................................... 112
REMOVAL FROM STORAGE............................................................................................... 86
S
SAFE OPERATING PRECAUTIONS ................................................................................... 46
SAFETY LABEL LOCATIONS............................................................................................... 11
Safety Precautions............................................................................................................... 65
background
116
INDEX
SAFETY..................................................................................................................................... 12
SEDIMENT CUP CLEANING ............................................................................................... 69
SERIAL NUMBER LOCATION............................................................................................. 92
SERVICING YOUR GENERATOR........................................................................................ 64
SPARK ARRESTER SERVICE ................................................................................................ 73
SPARK PLUG SERVICE ......................................................................................................... 71
Special Requirements......................................................................................................... 63
SPECIFICATIONS................................................................................................................... 97
STANDBY POWER................................................................................................................. 62
STARTING THE ENGINE ...................................................................................................... 47
STOPPING THE ENGINE...................................................................................................... 51
STORAGE PRECAUTIONS................................................................................................... 86
STORAGE PREPARATION ................................................................................................... 81
STORAGE................................................................................................................................. 81
System Ground..................................................................................................................... 62
T
TAKING CARE OF UNEXPECTED PROBLEMS............................................................... 89
TECHNICAL INFORMATION .............................................................................................. 92
THE IMPORTANCE OF MAINTENANCE.......................................................................... 64
The Importance of Proper Assembly............................................................................ 12
TRANSPORTING .................................................................................................................... 87
U
Unpacking .............................................................................................................................. 13
V
Vehicles and Transportation Hazards........................................................................... 10
W
Wheel Kit Installation.......................................................................................................... 15
WIRING DIAGRAM................................................................................................................ 99
background
QUICK REFERENCE INFORMATION
Fuel Type Regular unleaded gasoline with an
ethanol content of no more than 10%
and a pump octane rating of 86 or
higher (see page 21)
Engine Oil Type SAE 10W-30, API SJ or later (or
equivalent), for general use
(see page 18)
Maximum oil capacity:
Without oil filter replacement:
approximately 1.6 US qt (1.5 L)
With oil filter replacement:
approximately 1.8 US qt (1.7 L)
Spark Plug Type ZFR5F (NGK)
Electrode Gap 0.028–0.031 in (0.7–0.8 mm)
Maintenance Before each use Check engine oil level.
Check air cleaner.
Check GFCI operation.
Check battery electrolyte.
First 20 hours Change engine oil.
Subsequent See "MAINTENANCE SCHEDULE"
(see page 66)
background
PANTONE
186C
K
2024 Honda Motor Co., Ltd. -All Rights Reserved
C
EB10000
31Z26627
00X31-Z26-6270
Printed in China
英AH
FM
H i
GENERATOR
EB10000
Owner’s Manual
3mm
See page 12 for instructions on assembling your generator.
See page 17 for Initial Use Instructions.

Specifications

Indexed Terms: Generator, Industrial