Mi-T-M JP-Electric Operator's Manual 1
©Copyright 2005, Mi-T-M Corporation Form #37-0595-E/S-012523
CAUTION
RISK OF INJURY!
READ MANUAL BEFORE OPERATING!
This manual is an important part of the pressure washer
and must remain with this unit!
THE JOB PRO
®
JP-SERIES
OPERATION MANUAL
COLD WATER ELECTRIC
PRESSURE WASHER
PARTS LIST

2 Mi-T-M JP-Electric Operator's Manual
WARNING: This product can expose you to
chemicals including Lead, which is known to
the State of California to cause cancer and birth
defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov
WARNING
TABLE OF CONTENTS
INTRODUCTION .............................................................................................................3
IMPORTANT SAFETY WARNINGS.................................................................................4
ELECTRICAL PRECAUTIONS ...................................................................................................................4
SPRAY PRECAUTIONS .............................................................................................................................5
MISCELLANEOUS SAFETY PRECAUTIONS ............................................................................................5
DETERGENT CLEANING PRECAUTIONS .................................................................................................7
FEATURES .............................................................................................................. 8 & 10
SAFETY DECALS & PLACEMENT ........................................................................ 9 & 11
INSTALLATION & PREPARATION ................................................................................12
ATTIRE: ....................................................................................................................................................12
SETUP: ....................................................................................................................................................12
POWER CORD CONNECTION: ............................................................................................................... 12
NOZZLE REVIEW (2503 AND 3004): .....................................................................................................13
NOZZLE REVIEW (1002 AND 1502): ......................................................................................................13
NOZZLE CONNECTION: .........................................................................................................................14
WATER SUPPLY: ...................................................................................................................................... 14
UNLOADER: ............................................................................................................................................15
THERMAL RELIEF VALVE: ....................................................................................................................... 15
PRE-START INSPECTION PROCEDURES: ............................................................................................. 15
OPERATING INSTRUCTIONS ......................................................................................16
PRIMING THE PUMP: ..............................................................................................................................16
START-UP: ...............................................................................................................................................16
CLEANING WITH DETERGENTS: ............................................................................................................17
SHUTDOWN: ...........................................................................................................................................17
STORAGE & MAINTENANCE ....................................................................................... 18
SPECIFIC MAINTENANCE: .....................................................................................................................18
WINTERIZING: ......................................................................................................................................... 18
STARTING UNIT AFTER EXTENDED STORAGE: ....................................................................................19
TROUBLESHOOTING ...................................................................................................20
ACCESSORIES ..............................................................................................................22
STATEMENT OF WARRANTY ......................................................................................23

Mi-T-M JP-Electric Operator's Manual 3
Congratulations on the purchase of your Job Pro® pressure washer! You can be assured your Job Pro® pressure
washer was constructed and designed with quality and performance in mind. Each component has been rigorously
tested to ensure the highest level of acceptance.
This operator's manual was compiled for your benet. By reading and following the simple safety, installation, oper-
ation, maintenance and troubleshooting steps described in this manual, you will receive years of trouble free opera-
tion from your Job Pro® pressure washer. The contents of this manual are based on the latest product information
available at the time of publication. Mi-T-M® reserves the right to make changes in price, color, materials, equip-
ment, specications or models at any time without notice.
! IMPORTANT !
THESE PARAGRAPHS ARE SURROUNDED BY A "SAFETY ALERT BOX". THIS BOX IS USED TO
DESIGNATE AND EMPHASIZE SAFETY WARNINGS THAT MUST BE FOLLOWED WHEN OPERATING
THIS PRESSURE WASHER.
ACCOMPANYING THE SAFETY WARNINGS ARE "SIGNAL WORDS" WHICH DESIGNATE THE DEGREE
OR LEVEL OF HAZARD SERIOUSNESS. THE "SIGNAL WORDS" USED IN THIS MANUAL ARE AS
FOLLOWS:
DANGER:INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, WILL RESULT
IN DEATH OR SERIOUS INJURY.
WARNING: INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD
RESULT IN DEATH OR SERIOUS INJURY.
CAUTION: INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED MAY RESULT
IN MINOR OR MODERATE INJURY.
THE SYMBOLS SET BELOW THIS PARAGRAPH ARE "SAFETY ALERT SYMBOLS". THESE SYMBOLS ARE
USED TO CALL ATTENTION TO ITEMS OR PROCEDURES THAT COULD BE DANGEROUS TO YOU OR
OTHER PERSONS USING THIS EQUIPMENT.
ALWAYS PROVIDE A COPY OF THIS MANUAL TO ANYONE USING THIS EQUIPMENT. READ ALL
INSTRUCTIONS BEFORE OPERATING THIS PRESSURE WASHER AND ESPECIALLY POINT OUT THE
"SAFETY WARNINGS" TO PREVENT THE POSSIBILITY OF PERSONAL INJURY TO THE OPERATOR.
Once the unit has been removed from the box, immediately write in the serial number of your unit in the space pro-
vided below.
SERIAL NUMBER_________________________________
Inspect for signs of obvious or concealed freight damage. If damage does exist, le a claim with the transportation
company immediately. Be sure that all damaged parts are replaced and that the mechanical problems are corrected
prior to operation of the unit. If you require service, contact Customer Service at 800-553-9053.
Please have the following information available for all service calls:
1.Model Number
2.Serial Number
3.Date and Place of Purchase
Mi-T-M Corporation
50 Mi-T-M Drive
Peosta, IA 52068
INTRODUCTION

4 Mi-T-M JP-Electric Operator's Manual
ELECTRICAL PRECAUTIONS
RISK OF ELECTRIC SHOCK OR ELECTROCUTION: WARNING
SERIOUS INJURY OR DEATH COULD OCCUR IF THE
PRESSURE WASHER IS NOT PROPERLY GROUNDED. YOUR
PRESSURE WASHER IS POWERED BY ELECTRICITY AND MAY
CAUSE ELECTRIC SHOCK OR ELECTROCUTION IF NOT USED
PROPERLY.
1. This product must be grounded. Make sure the pressure washer is equipped
with a GFCI built into the power supply cord. If this is not available, the
pressure washer must be plugged into a receptacle that is protected by a
GFCI. Disconnect when not in use.
2. If your unit is equipped with a GFCI, DO NOT drop the GFCI as damage
could result. If the GFCI is accidentally dropped, be certain to test the
GFCI before using to ensure it is working properly. (Follow instructions on
GFCI for test procedures.)
3. Always be certain the unit is receiving proper voltage. Disconnect when
not in use.
4. DO NOT modify the plug provided with the product. If it will not t the
outlet, have a proper outlet installed by a qualied electrician. DO NOT
use any type of adapter.
WARNING ELECTRICAL SHOCK MAY OCCUR FROM ELECTRICAL
CORD.
5. Check power cord for signs of crushing, cutting or heat damage. If
replacement of plug or cord is needed use only identical replacement parts
6. DO NOT use extension cords with this pressure washer.
7. Keep all connections dry and off the ground. Do not allow electrical cords
to lay in water or in such a position where water could come in contact
with them. Do not touch plug with wet hands.
8. DO NOT pull on the electrical cord to disconnect from the outlet.
WARNING ELECTRICAL SHOCK MAY OCCUR IF PRESSURE
WASHER IS NOT OPERATED PROPERLY.
9. DO NOT direct spray on or into electrical installations of any kind! This
includes electrical outlets, light bulbs, fuse boxes, transformers, the unit
itself, etc.
10. DO NOT allow metal components of the pressure washer to come in contact
with live electrical components.
11. Never operate the pressure washer with safety guards/covers removed or
damaged.
WARNING SERIOUS INJURY OR DEATH MAY OCCUR IF
UNQUALIFIED PERSONS ATTEMPT ELECTRICAL REPAIRS.
12. Any electrical wiring or repairs performed on this pressure washer should
be done by Authorized Service Personnel in accordance with National and
Local electrical codes.
13. Before opening any electrical enclosure, always shut off the pressure washer,
relieve pressure and unplug the pressure washer from the power source.
Allow the pressure washer to cool down. Never assume the pressure
washer is safe to work on just because it is not operating. It could restart
at any time! Service in a clean, dry, at area.
IMPORTANT SAFETY WARNINGS

Mi-T-M JP-Electric Operator's Manual 5
SPRAY PRECAUTIONS
DANGER RISK OF INJECTION OR SEVERE CUTTING INJURY: KEEP
CLEAR OF NOZZLE. DO NOT DIRECT DISCHARGE STREAM
AT PERSONS OR PETS. WHEN USING THIS PRODUCT, BASIC
PRECAUTIONS SHOULD ALWAYS BE OBSERVED, INCLUDING
THE FOLLOWING:
1. Keep clear of the nozzle and spray! Never put your hand, ngers or body
directly over the spray nozzle.
2. Never point the high pressure spray at yourself or anyone else.
3. This product is to be used only by trained operators.
4. Always keep operating area clear of all persons.
5. Never allow children or adolescents to operate this unit.
6. SEEK EMERGENCY MEDICAL CARE if the spray appears to have penetrated
the skin! DO NOT TREAT AS A SIMPLE CUT!
7. High pressure hoses should be inspected daily for signs of wear. If evidence
of failure exist, promptly replace all suspect hoses to prevent the possibility
of injury from the high pressure spray. If a hose or tting is leaking, NEVER
PLACE YOUR HAND DIRECTLY ON THE LEAK.
8. NEVER operate the gun with the trigger wired in the open position. To
prevent accidental discharge, the trigger gun should be securely locked
when not in use.
9. Do not move the unit by pulling on the hose
10. Before removing the spray nozzle or servicing the unit, ALWAYS shut off
the unit and trigger the gun to release trapped pressure. (Even after you
shut off the unit, there is high pressure water left in the pump, hose and
gun until you release it by triggering the gun.)
11. Do not leave pressurized unit unattended. Shut off the pressure washer
and relieve trapped pressure before leaving.
MISCELLANEOUS SAFETY PRECAUTIONS
RISK OF EXPLOSION OR FIRE: WARNING SERIOUS INJURY OR
DEATH MAY OCCUR FROM NORMAL SPARKS IN THE MOTOR
AND ELECTRICAL SYSTEM.
1. DO NOT operate unit in an area where ammable gas vapors may be
present. An electric spark may cause an explosion or re.
2. DO NOT spray ammable liquids. Do not spray in an area containing
combustible dust, liquids or vapors.
RISK OF ASPHYXIATION:
WARNING SERIOUS INJURY OR DEATH MAY OCCUR FROM
INHALING DANGEROUS VAPORS.
1. Follow all safety instructions provided with the materials you are spraying.
Use of a respirator may be required when working with some materials.
Do not use this pressure washer to dispense hazardous detergents.
IMPORTANT SAFETY WARNINGS

6 Mi-T-M JP-Electric Operator's Manual
RISK OF BURSTING
WARNING SERIOUS INJURY MAY OCCUR FROM A PRESSURE
WASHER MALFUNCTION OR EXPLODING ACCESSORIES IF
INCORRECT SYSTEM COMPONENTS, ATTACHMENTS OR
ACCESSORIES ARE USED.
1. Never make adjustments to the factory set pressures.
2. Never exceed manufacturers maximum allowable pressure rating of
attachments.
3. Use only manufacturer recommended repair parts for your pressure washer.
WARNING SERIOUS INJURY OR DEATH MAY OCCUR IF
ATTEMPTING TO START THE PRESSURE WASHER WHEN THE
PUMP IS FROZEN.
4. In freezing temperatures, the unit must always be warm enough to ensure
there is no ice formation in the pump. Do not start the pressure washer
if it has been transported in an open or underheated vehicle without rst
allowing the pump to thaw.
RISK FROM MOVING PARTS
WARNING SERIOUS INJURY MAY OCCUR TO THE OPERATOR
FROM MOVING PARTS ON THE PRESSURE WASHER.
1. Never make adjustments to the unit while it is connected to the power
source.
2. Do not operate the unit without all protective covers in place.
3. Before servicing the pressure washer, turn the unit off, disconnect from the
power source, relieve the water pressure and allow the unit to cool down.
Service in a clean, dry, at area.
4. Follow the maintenance instructions specied in the manual.
RISK OF BODILY INJURY
WARNING SERIOUS INJURY CAN OCCUR FROM LOOSE DEBRIS
BEING PROPELLED AT HIGH SPEED FROM THE SPRAY GUN.
1. Always wear protective goggles when operating the unit to shield the eyes
from ying debris and detergents.
2. Do not direct spray toward fragile materials such as glass. Shattering could
result in serious injury.
WARNING INJURY MAY OCCUR IF THE OPERATOR LOSES
BALANCE CAUSED BY THE THRUST OF WATER TRAVELING
THROUGH THE SPRAY NOZZLE.
1. Stay alert-watch what you are doing. Do not operate the unit when fatigued
or under the inuence of alcohol or drugs.
2. Never squeeze the trigger unless securely braced. DO NOT overreach or
stand on unstable support. Wet surfaces can be slippery, wear protective
foot gear and keep good footing and balance at all times. Never trigger
the gun while on a ladder or roof.
WARNING INJURY MAY OCCUR FROM THE PRESSURE WASHER.
1. Always hold on rmly to the gun/lance assembly when starting and operating
the unit. Failure to do so can cause the lance to fall and whip dangerously.
2. Know how to stop the pressure washer and bleed pressures quickly. Be
thoroughly familiar with controls.
IMPORTANT SAFETY WARNINGS

Mi-T-M JP-Electric Operator's Manual 7
DETERGENT CLEANING PRECAUTIONS
RISK OF BODILY INJURY:
WARNING SERIOUS INJURY OR DEATH MAY OCCUR FROM
DETERGENTS CONTACTING THE SKIN.
1. DO NOT use solvents, highly corrosive detergents or acid type cleaners
with this pressure washer. Use only mild detergents.
2. KNOW YOUR DETERGENTS! Be prepared to tell a physician exactly what
you are using in the event of an emergency. Read the Material Safety
Data Sheet (MSDS) provided with your detergent and all detergent labels.
Follow all appropriate instructions regarding preparation, use, safety and
transportation.
3. Protective equipment such as rubber suits, gloves and respirators are
advisable, especially when using cleaning detergents.
4. Keep all detergents out of the reach of children.
! SAVE THESE INSTRUCTIONS !
IMPORTANT SAFETY WARNINGS

8 Mi-T-M JP-Electric Operator's Manual
FEATURES
FEATURES LISTING
1. Quick Connect Nozzle
2. Gun Assembly
3. GFCI
4. Decal-Warning: Risk of Electrocution
5. High Pressure Discharge Hose
6. Thermal Relief Valve
7. Water Outlet
8. Water Inlet Strainer
9. Water Inlet
10. Detergent Strainer
11. Detergent Hose
12. Oil Sight Glass
13. Pump
14. Adjustment Unloader Knob
15. Decal-Warning: Risk of Injection/Explosion
16. On/Off Switch
17. Decal-Warning: Caution
JP-SM-ELECTRIC FEATURES 070522

Mi-T-M JP-Electric Operator's Manual 9
SAFETY DECALS & PLACEMENT
DO not remove safety decals from unit unless Replacing with most current safety decal!!
CAUTION / PRECAUCION
IMPORTANT / IMPORTANTE
1. Read operator's manual
carefully before using.
2. Spray gun can kick back.
Hold with both hands.
3. Risk of eye injury. Always
wear eye protection.
4. See the operator's manual
for proper chemical usage.
1. Lea cuidadosamente el manual del
operador antes de usar.
2. El revolver rociadora puede
retroceder violentemente. Sujétela
con ambas manos.
3. Riesgo de lesiones a los ojos. Use
siempre protección para los ojos.
4. Para un uso químico apropiado
consulte el Manual del Operador.
CONNECT TO AN
INDIVIDUAL BRANCH
CIRCUIT ONLY.
• For indoor and outdoor use.
• Store indoors.
• Avoid pump damage.
Protect from freezing. Do
not run for more than 3
minutes with spray gun not
triggered.
• If connected to a circuit
protected by fuses, use
time-delay fuses marked D.
• Para uso interior y exterior.
• Almacene bajo techo.
• Evite daños a la bomba. Protéjala
contra la congelación. No haga
funcionar por más de 3 minutos
sin accionar el gatillo de la pistola.
• Si le raccordement se fait á un
cicuita protégé par fusibles,
utiliser un fusible temporisé
marqué D.
RIESGO DE LESIONESRISK OF INJURY
34-1015/080912
CONECTAR SOLAMENTE
A UN CIRCUITO
DERIVADO INDIVIDUAL.
RISK OF INJECTION OR SEVERE INJURY
Never put your hand, fingers or body directly
over the spray nozzle.
34-1253/07272012
RIESGO DE INYECCIÓN O LESIÓN SEVERA
Nunca coloque la mano, los dedos o el cuerpo
directamente sobre la boquilla de rocío.
WARNING
ADVERTENCIA
CAUTION
PRECAUCION
34-1254/051322
Hot discharge fluid. Do not
touch or direct discharge
stream at people.
Pump surface temperature
is same as inlet water
temperature.
180°F maximum water inlet
temperature.
Descarga de caliente.¡No
dirija el chorro de descarga
hacia personas. De
temperatura del superficie la
bomba como lo mismo
entrada de temperatura del
agua.
Entrada de temperatura del
agua la máximo 180°F.
WARNING ADVERTENCIA
RISK OF EXPLOSION: Do not
spray flammable liquids.
RISK OF ELECTROCUTION: Do
not spray electrical apparatus
and wiring.
RISK OF INJECTION OR
SEVERE CUTTING INJURY:
Keep clear of nozzle. Do not
direct discharge stream at persons.
RISQUE D'EXPLOSION: Ne pas pulvériser
de liquides inflammables.
RISQUE D'ÉLECTROCUTION: Ne pas
vaporiser sur des appareils et des fils
électriques.
RISQUE D'INJECTION OU DE COUPURES
GRAVES: Rester à l’écart de la buse. Ne
jamais diriger le jet vers des personnes
ou soi-même.
RIESGO DE EXPLOSI
ÓN
: No
rocie liquidos inflamables.
RIESGO DE ELECTROCUCIÓN:
No rocíe el aparato y el cableado
eléctricos.
RIESGO DE INYECCI
ÓN O LESIÓN
DE CORTE
: Manténgase alejado de la
boquilla. No dirija la corriente de descarga
hacia las personas.
34-4125/062322
AVERTISSEMENT
WARNING / ADVERTENCIA
34-2796/071019
RISK OF ELECTROCUTION. DO NOT REMOVE THIS TAG.
WARNING: Cancer and Reproductive Harm —
www.P65warnings.ca.gov/
1. Connect only to a properly grounded outlet. Do not remove
ground pin.
2. Inspect cord before using. Do not use if cord is damaged.
3. Keep all connections dry and off the ground.
4. Do not touch plug with wet hands.
5. This product is provided with a Ground Fault Circuit
Interrupter (GFCI) built into the power cord plug. If
replacement of plug or cord is needed, use only identical
replacement parts.
6. Do not use an extension cord with this machine.
7. Read the operator's manual before using.
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS
COULD RESULT IN A SEVERE ELECTRICAL SHOCK.
RIESGO DE ELECTROCUCION. NO RETIRE ESTA CALCOMANIA.
ADVERTENCIA: Peligro de cáncer y daño reproductivo —
www.P65warnings.ca.gov/
1. Conecte solamente a un tomacorriente apropiadamente conectado a
tierra. No retire la clavija de conexion a tierra.
2. Antes de usar inspeccione el cordon. si el cordon esta dañado no la
use.
3. Mantenga todas las conexiones secas y alejadas del suelo.
4. No toque el enchufe con las manos mojadas.
5. Este producto viene con un interruptor de circuito de falla de
conexion a tierra (GFCI) incorporado al enchufe del cordon
electirco. Use solo piezas identicas de repuesto si se necesita un
reemplazo del enchufe o del cordon.
6. No use un cordon de extension con esta maquina.
7. Antes de usar lea el manual del operador.
EL NO SEGUIR LAS INSTRUCCIONES DE ARRIBA PUEDE
RESULTAR EN UN CHOQUE ELECTRICO GRAVE.
34-4126/062322
WARNING
If connection is made to
a potable water system,
the system shall be
protected against backflow.
Si la conexión se hace a un
sistema de agua potable, el
sistema será protegido contra
la expulsión.
Si l'appareil est raccordé à un
réseau d'eau potable, il doit
être protégé contre les
refoulements.
ADVERTENCIA AVERTISSEMENT
34-1068/080912
IMPORTANT/IMPORTANTE
Do not operate
without water.
Do not use
water that is
over 125°F.
No se opere sin agua.
No se use con agua
con temperaturas de
mas de 52 °C.

10 Mi-T-M JP-Electric Operator's Manual
FEATURES
FEATURES LISTING
JP-LG-ELECTRIC-FEATURES 040422
1. Motor Overload
2. Decal-Warning/Caution/Operating
3. Motor
4. Decal- Warning: Risk of Injection/Explosion
5. Pump
6. Detergent Strainer
7. Detergent Hose
8. Adjustment Unloader Knob
9. Adjustable Detergent Injector
10. Water Inlet
11. Decal- Warning: Potable Water
12. Water Outlet
13. High Pressure Discharge Hose
14. On/Off Switch
15. Decal-Warning: Risk of Electrocution
16. Power Cord
17. GFCI
18. Tag-Warning: Risk of Electrocution
19. Gun Assembly
20. Decal-Warning: Risk of Injection
21. Quick Connect Nozzle

Mi-T-M JP-Electric Operator's Manual 11
SAFETY DECALS & PLACEMENT
DO not remove safety decals from unit unless replacing with most current safety decal!!
34-1471/081712
RISK OF ELECTROCUTION. DO NOT REMOVE THIS TAG.
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS
COULD RESULT IN A SEVERE ELECTRICAL SHOCK.
RIESGO DE ELECTROCUCION. NO RETIRE ESTA CALCOMANIA.
EL NO SEGUIR LAS INSTRUCCIONES DE ARRIBA PUEDE
RESULTAR EN UN CHOQUE ELECTRICO GRAVE.
ADVERTENCIA
WARNING
1.Conecte solamente a una toma corriente que está bien fundado. No
quite la pata de conexión de la tierra.
2. Antes de usar inspeccióne la cuerda. No use si la cuerda està dañando.
3. Mantenga los conexiones secos y apar tados de la tierra.
4.No torque el enchufe con manos mojados.
5.Este producto debe conectarse a tierra. Asegúrese de que la lavadora
a presión esté equipada con un Interruptor de circuito de falla a tierra
(Ground Fault Circuit Interrupter, GFCI) incorporado en el cordón de
alimentación. Si no lo tiene, debe conectarse la lavadora a presión
únicamente en un receptáculo que esté protegido por un Interruptor de
circuito de falla a tierra. Desconéctela cuando no esté en uso.
6.No use una cuerda extensión con la unidad.
7.Antes de usar lea y entienda todas las instrucciónes y el manual de
operación.
1.Connect only to a properly grounded outlet. Do not remove ground pin.
2.Inspect cord before using. Do not use if cord is damaged.
3.Keep all connections dry and off the ground.
4.Do not touch plug with wet hands.
5.This unit may be provided with a Ground Fault Circuit Interrupter (GFCI)
built into the power cord plug. If replacement of the plug or cord is
needed, use only identical replacement parts. If this unit is not provided
with a GFCI, this unit should only be connected to a power supply
receptacle protected by a ground fault circuit interrupter.
6.Do not use an extension cord with this machine.
7.Read the operator's manual before using.
CAUTION
PRECAUCION
34-1254/051322
Hot discharge fluid. Do not
touch or direct discharge
stream at people.
Pump surface temperature
is same as inlet water
temperature.
180°F maximum water inlet
temperature.
Descarga de caliente.¡No
dirija el chorro de descarga
hacia personas. De
temperatura del superficie la
bomba como lo mismo
entrada de temperatura del
agua.
Entrada de temperatura del
agua la máximo 180°F.
WARNING ADVERTENCIA
RISK OF EXPLOSION: Do not
spray flammable liquids.
RISK OF ELECTROCUTION: Do
not spray electrical apparatus
and wiring.
RISK OF INJECTION OR
SEVERE CUTTING INJURY:
Keep clear of nozzle. Do not
direct discharge stream at persons.
RIESGO DE EXPLOSI
ÓN
: No
rocie liquidos inflamables.
RIESGO DE ELECTROCUCIÓN:
No rocíe el aparato y el cableado
eléctricos.
RIESGO DE INYECCI
ÓN O LESIÓN
DE CORTE
: Manténgase alejado de la
boquilla. No dirija la corriente de descarga
hacia las personas.
34-1017/080612
RISK OF INJECTION OR SEVERE INJURY
Never put your hand, fingers or body directly
over the spray nozzle.
34-1253/07272012
RIESGO DE INYECCIÓN O LESIÓN SEVERA
Nunca coloque la mano, los dedos o el cuerpo
directamente sobre la boquilla de rocío.
WARNING
ADVERTENCIA
34-1477/080612
WARNING/ADVERTENCIA
If connection is made to
a potable water system,
the system shall be
protected against backflow.
Si la conexión se hace a un
sistema de agua potable, el
sistema será protegido
contra la expulsión.
34-1068/080912
IMPORTANT/IMPORTANTE
Do not operate
without water.
Do not use
water that is
over 125°F.
No se opere sin agua.
No se use con agua
con temperaturas de
mas de 52 °C.
CAUTION
1. Read operator's manual carefully before
using.
2. Spray gun can kick back. Hold with both
hands.
3. Risk of eye injury. Always wear eye protection.
4. See the operator's manual for proper
chemical usage.
1. Lea cuidadosamente el manual del operador antes de usar.
2. El revolver rociadora puede retroceder violentemente.
Sujétela con ambas manos.
3. Riesgo de lesiones a los ojos. Use siempre protección
para los ojos.
4. Para un uso químico apropiado consulte el Manual del
Operador.
IMPORTANT
• For indoor and outdoor use.
• Store indoors.
• Avoid pump damage. Protect from freezing.
Do not run for more than 3 minutes with
spray gun not triggered.
• If connected to a circuit protected by fuses,
use time-delay fuses only.
• Para uso interior y exterior.
• Almacene bajo techo.
• Evite daños a la bomba. Protéjala contra la congelación.
No haga funcionar por más de 3 minutos sin accionar el
gatillo de la pistola.
• Si se conecta a un circuito protegido por fusibles, use
fusibles con retardo solamente.
RIESGO DE LESIONESRISK OF INJURY
34-4058/111821
PRÉCAUTION
IMPORTANT

12 Mi-T-M JP-Electric Operator's Manual
INSTALLATION & PREPARATION
ATTIRE:
Proper attire is essential to your safety. It is advised to utilize whatever
means necessary to protect eyes, ears, and skin. Additional safety attire
(such as respiratory mask) may be required when using detergent cleaning
agents with this washer.
SETUP:
1. This unit should only be placed on a level surface to ensure proper lubrication
for the water pump while operating. NEVER spray water directly on the
unit!
2. Do not place unit in an area:
a. where there is evidence of oil or gas leaks.
b. where ammable gas vapors may be present.
3. Do not allow the unit to be exposed to rain, snow or freezing temperatures.
If any part of the unit becomes frozen; excessive pressure may build up
in the unit which could cause it to burst, resulting in possible serious injury
to the operator or bystanders.
4. Before each use, be certain the oil level is in the center of the sight glass.
If low, ll with Mi-T-M pump oil (#AW-4085-0016). DO NOT OVERFILL!
WARNING RISK OF
EXPLOSION!
DO NOT OPERATE UNIT IN AN
AREA WHERE FLAMMABLE
GAS VAPORS MAY BE PRES-
ENT. AN ELECTRIC SPARK
MAY CAUSE AN EXPLOSION.
RISK OF BURSTING!
DO NOT STORE / OPERATE
UNIT IN A FREEZING ENVI-
RONMENT.
DANGER RISK OF
ELECTROCUTION!
THIS UNIT MUST BE CON-
NECTED TO A PROPERLY
GROUNDED OUTLET. DO NOT
USE AN ADAPTER OR RE-
MOVE THE THIRD GROUND-
ING PRONG.
WARNING RISK OF
ELECTROCUTION!
TO REDUCE THE RISK OF
ELECTROCUTION, KEEP ALL
CONNECTIONS DRY AND
OFF THE GROUND. DO NOT
TOUCH PLUG WITH WET
HANDS.
POWER CORD CONNECTION:
1. Make certain the motor switch is in the "OFF" position.
2. Ensure electrical supply is identical to the specications listed on the
pressure washer data plate.
3. GROUNDING INSTRUCTIONS: This product must be grounded. If it should
malfunction or breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This product is equipped
with a cord having an equipment-grounding conductor. The plug must be
plugged into an appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
4. DANGER: Improper connection of the equipment-grounding conductor
can result in a risk of electrocution. Check with a qualied electrician or
service personnel if you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug - if it will not t the outlet, have a proper
outlet installed by a qualied electrician. Do not use any type of adaptor
with this product.
5. GROUND FAULT CIRCUIT INTERRUPTER PROTECTION:
a. SINGLE PHASE: If this pressure washer is provided with a Ground
Fault Circuit Interrupter (GFCI) built into the plug or the power supply
cord, test the GFCI each time it is plugged into an outlet according to
instructions on the GFCI. DO NOT use the pressure washer if the test
fails! The GFCI provides additional protection from the risk of electric
shock. Should replacement of the plug or cord become necessary, use
only identical replacement parts that include GFCI protection.
b. SINGLE PHASE: If this pressure washer is not provided with a GFCI,
this pressure washer should only be connected to a receptacle that
is protected by a Ground Fault Circuit Interrupter (GFCI) to comply with
the National Electric Code (NFPA 70) and to provide additional protection
from the risk of electric shock.
c. THREE PHASE: These pressure washers are not provided with GFCI
protection.
6. EXTENSION CORDS: Mi-T-M DOES NOT RECOMMEND THE USE OF
EXTENSION CORDS! If use of an extension cord is unavoidable, it must
be plugged into a GFCI found in circuit boxes or protected receptacles.
When using an extension cord, consult a qualied electrician to determine
the proper wire gauge needed for the length of the extension cord.

Mi-T-M JP-Electric Operator's Manual 13
WARNING RISK OF
INJECTION CAUSING
SEVERE INJURY!
NEVER LOOK DIRECTLY AT THE
NOZZLE ORIFICE UNLESS IT IS
DISCONNECTED FROM THE
GUN/WAND ASSEMBLY!
CONNECTION OF Q.C. NOZZLES
QUICK-CONNECT (Q.C.)
INSTALLATION & PREPARATION
SINGLE PHASE: Use only 3-wire extension cords that have 3-prong grounding-
type plugs and 3-pole cord connectors that accept the plug from the product.
THREE PHASE: Use only 4 wire extension cords that have 4-prong grounding
type plugs and 4-pole cord connectors that accept the plug from the product.
Use only extension cords that are intended for outdoor use. These ex-
tension cords are identied by a marking "Acceptable for use with outdoor
appliances; store indoors while not in use." Use only extension cords having
an electrical rating not less than the rating of the product. Do not use dam-
aged extension cords. Examine extension cord before using and replace
if damaged. Do not abuse extension cord and do not pull on any cord to
disconnect. Keep cord away from heat and sharp edges. Always connect
or disconnect the extension cord from the receptacle before connecting or
disconnecting the product from the extension cord.
7. Ensure the area between the pressure washer cord and outlet is kept dry.
8. Insert the male plug into a grounded AC outlet. DO NOT use an adapter
OR remove the grounding plug!!
NOZZLE REVIEW (2503 AND 3004):
Various nozzles may be quick-connected into the end of the wand to change
the spray pattern or use the detergent feature. When using Quick Connects
(Q.C.), be certain the connection is securely locked. If not, the high pressure
water may shoot the nozzle from the wand, causing severe injury or serious
damage. To determine spray fan, refer to the actual number stamped on the
nozzle. The rst two digits indicate the spray fan in degrees, i.e.; 00=0”,
15=15°, 25=25°, 65=detergent/low pressure.
1. The 0” nozzle (RED): This is a blasting nozzle. It delivers a very concentrated
stream of water. Be cautious when using the straight narrow stream. It is
not recommended for use on painted or wood surfaces, or items attached
with adhesive backings. Uses: Removing weeds from sidewalk cracks,
stubborn stains from concrete, masonry, aluminum and steel, caked mud
from equipment, and cleaning lawn mower undersides.
2. The 15° nozzle (YELLOW): This is a chiseling nozzle. The spray should
be directed at a 45° angle to the surface and used like a scraper to remove
paint, grease and dirt. Uses: Surface preparation (removing mildew stains
and paint chips).
3. The 25° nozzle (GREEN): This is a ushing nozzle. This pattern is best
suited for ushing dirt, mud, and grime. Uses: Wet sweeping leaves from
walks, curbs and driveways, cleaning stable oors, washing swimming pool
bottoms, degreasing engines.
4. The 65° nozzle (BLACK): This is a low pressure detergent application
nozzle. This broad spray pattern distributes solution over vast areas under
low pressure. Uses: Detergent application, misting or rinsing.
NOZZLE REVIEW (1002 AND 1502):
NOTE: Depending on your model, there are two different variations for
adjusting your nozzle. Nozzle assembly should NOT be connected to
the gun assembly at this time.
Variation 1 (see Figure A)
1. Selections of high and low pressure can be achieved by pulling the nozzle
cover at the end of the wand "TOWARD" yourself for the High Pressure
setting, and pushing the nozzle cover "AWAY" from yourself for Low Pressure
and detergent application.
2. The spray pattern can be adjusted from 0° to 65° by rotating the nozzle cover
at the end of the wand in a clockwise and counter-clockwise direction. Be
cautious when using the straight narrow stream. It is not recommended
for use on painted or wood surfaces OR items attached with adhesive
backings.
FIGURE A. ADJUSTABLE NOZZLE
LOW PRESSURE / DETERGENT
NOZZLE COVER
HIGH PRESSURE
NOZZLE COVER

14 Mi-T-M JP-Electric Operator's Manual
WATER SUPPLY:
1. Select a water supply hose which is a quality grade of garden hose measuring
at least 3/4" ID and no longer than 50 feet.
2 Check the water inlet strainer to ensure it is clean and free of any obstructions.
Periodic cleaning of the water strainer will help prevent pump problems.
As a strainer becomes obstructed, it restricts proper ow of water to the
pump. This can cause cavitation which will result in premature failure of
pump packings and valves. Using a screw driver, remove the screen; clean
or replace with Mi-T-M #19-0001 if necessary.
3. Connect the hoses.
a. Connect one end of the water supply hose to the water inlet of the unit.
b. Connect the other end of the hose to your pressurized water supply.
NOTE: Do not use a non-pressurized water supply (i.e. from a well or
pond) with this unit.
c. Connect the high pressure discharge hose to the water outlet of the unit.
4. Follow the incoming water requirements listed below:
a. Water pressure must be a minimum of 20 pounds per square inch (PSI)
and a maximum of 125 PSI. (A typical outdoor faucet will generally
supply this PSI if turned completely "ON".)
b. Incoming GPM must be approximately one gallon more than the outgoing
GPM stated on the pressure washer nameplate. (You can check GPM
by timing how long it takes to ll a 5 gallon container.
c. Incoming water temperature must not exceed 140°F (78°C). If unit is
equipped with hot packing kit (2ME1 models only), temperature can not
exceed up to 190°F (87°C). Excessive pump damage may result if the
water temperature exceeds this acceptable level.
5. Never allow the unit to operate without the incoming water line attached
and the water supply turned all the way on.
INSTALLATION & PREPARATION
Variation 2 (see Figure B)
1. Selection of high pressure can be achieved by turning the protective collar
clockwise as shown in Drawing 1, Figure B. While in the high pressure
mode, water is directed solely through the 15° spray nozzle creating a
concentrated high pressure "fan" spray.
2. Selection of low pressure detergent application can be achieved by turning
the collar counterclockwise as shown in Drawing 2, Figure B. Once the
pressure is low enough, the detergent injector on the pressure washer will
draw detergent into the system. As the collar is turned, a water/detergent
mixture exits not only from the spray nozzle, but also around the nozzle.
This creates a "fan/cone" combination spray pattern.
NOZZLE CONNECTION:
1. Be certain the trigger gun is locked in the "OFF" position. See WARNING,
left.
2. The nozzle assembly should be disconnected from the gun/wand assembly
at this by retracting the locking ring on the quick-connect tting to remove
the nozzle (see Figure A) or by unscrewing the nozzle/lance assembly from
the gun/lance assembly (see Figure B).
QUICK-CONNECT FITTING
WARNING RISK OF SEVERE
INJURY!
THE TRIGGER GUN SHOULD
ALWAYS BE LOCKED IN THE
OFF POSITION WHEN NOT IN
USE!
CHECK WATER INLET STRAINER
Drawing 2
Drawing 1
FIGURE B.
ADJUSTABLE NOZZLE
CONNECT
DISCONNECT
FIGURE A FIGURE B

Mi-T-M JP-Electric Operator's Manual 15
PRE-START INSPECTION PROCEDURES:
Before starting the unit, perform the following procedures:
1. Inspect electrical cord for cuts. If a cut is found, DO NOT TOUCH OR USE
ELECTRICAL CORD! Replace cord before starting the unit.
2. Check the oil level in the pump.
3. Inspect the inlet water strainer. Clean or replace if necessary. See "Water
Supply", #2, pg. 15.
4. Check all hose connections to ensure they are securely tightened. See
"Water Supply", #3, pg. 15.
5. Inspect for system water leaks and oil leaks. Be sure that all damaged
parts are replaced and that the mechanical problems are corrected prior
to operation of the unit. If service is needed, contact Customer Service.
6. Inspect high pressure hose for kinking, cuts or leaks. If a cut or leak is
found, DO NOT USE HOSE! Replace hose before starting unit. Be sure
that all damaged parts are replaced and that the mechanical problems
are corrected prior to operation of the unit. If you need service, contact
Customer Service.
INSTALLATION & PREPARATION
UNLOADER:
The unloader valve on your machine is equipped with an adjustment knob
to adjust the pressure. Should less pressure be required, simply turn the ad-
justment knob counterclockwise. To set back to maximum, turn adjustment
knob completely clockwise. DO NOT OVERTIGHTEN!
CAUTION
RISK OF UNIT DAMAGE!
DO NOT OVERTIGHTEN THE
UNLOADER. BREAKAGE WILL
RESULT IN IMMEDIATE LOSS OF
WATER PRESSURE AND COSTLY
REPAIRS.
THERMAL RELIEF VALVE:
To ensure the water temperature does not exceed acceptable levels, never allow
the pressure washer to operate in the bypass mode (with the unit running and
the trigger closed) for more than three minutes.
A thermal relief valve has been added to this unit to protect the pump. This valve
will open and release water if the water temperature in the pump has exceeded
140° F. This will allow fresh, cool water to enter the system, preventing premature
failure of pump packings.
END OF PREPARATION INSTRUCTIONS
WARNING
THE FOLLOWING PAGES CONTAIN OPERATING AND MAINTENANCE INSTRUCTIONS
DO NOT ATTEMPT TO OPERATE THIS PRESSURE WASHER UNTIL YOU HAVE READ AND UNDERSTOOD ALL
SAFETY PRECAUTIONS AND INSTRUCTIONS LISTED IN THIS MANUAL.
INCORRECT OPERATION OF THIS UNIT CAN CAUSE SERIOUS INJURY!!
DO NOT ALTER OR MODIFY THIS EQUIPMENT IN ANY MANNER!

16 Mi-T-M JP-Electric Operator's Manual
PRIMING THE PUMP:
1. It is essential to prime the pump on initial start-up and each time the water
supply is disconnected from the unit after initial use.
2. Lay the high pressure hose out to remove any loops. Water ow will constrict
the hose, creating tight loops if the hose is not straight.
3. Securely connect the gun assembly to the high pressure hose.
NOTE: The nozzle should NOT be connected to the gun assembly at this
time. See "Nozzle Connection" pg. 14.
4. With the trigger gun locked in the "OFF" position, turn the water supply
completely on. Pointing the gun in a safe direction, unlock the trigger gun
and squeeze the trigger.
5. Low pressure water will begin owing from the hose/gun assembly. This
allows the unit to prime and purge any air from the system. The unit is
primed when water ow is uninterrupted by air.
6. Once the unit is primed, release the trigger and lock the gun in the "OFF"
position. Securely connect the nozzle assy. (See "Nozzle Connection" pg.
14.)
START-UP:
1. Refer to the "Safety Precautions" pgs. 4-7 before starting the unit.
2. Locate the Safety Decals on your unit and heed their warnings.
3. With the gun locked in the "OFF" position, point the trigger gun away from
yourself or anyone else. Ensure water supply is turned completely on.
4. Disengage the safety lock-off on the gun and squeeze the trigger. Low
pressure water will begin owing from the nozzle.
5. Before starting the unit, brace yourself as the gun will kickback from the
high pressure created by the pump once the unit has started.
6. Move the switch to the "ON" position. On the 1002/1502 units, this switch
includes a circuit breaker for protection of the motor. In case of excess
load, the circuit breaker will automatically move the switch to the "OFF"
position. To restart, move the On/Off Switch to the "ON" position again.
7. Once the unit is turned on, perform the following procedures with the gun
open:
a. Inspect for system water leaks and oil leaks. If a leak is found, TURN
UNIT OFF IMMEDIATELY! Be sure that all damaged parts are replaced
and that the mechanical problems are corrected prior to operation of
the unit. If you require service, contact Mi-T-M Customer Service.
b. Inspect high pressure hose for kinking cuts and leaks. If a cut or leak
is found, DO NOT TOUCH HOSE AT CUT OR LEAK!!! TURN UNIT OFF
IMMEDIATELY! Replace hose before restarting the unit. Be sure that
all damaged parts are replaced and that the mechanical problems are
corrected prior to operation of the unit. If you require service, contact
Mi-T-M Service.
c. Inspect electrical cord for cuts. If a cut is found, DO NOT TOUCH OR
USE ELECTRICAL CORD! Replace cord before starting the unit.
8. Trigger the gun several times. Be certain to LOCK the trigger gun in the
"OFF" position whenever changing the nozzle. NEVER look directly into
the nozzle! High pressure water creates a risk of severe injury!
9. Do not allow unit to operate in bypass mode (with trigger closed) for more
than three minutes without triggering the gun. Failure to follow this simple
rule can cause premature failure of pump packing seals, resulting in costly
pump repair.
10. Because your pressure washer delivers a high pressure spray and a variety
of spray patterns, there are many cleaning jobs that can be done without
the use of detergents. If a cleaning agent is required, see "Cleaning with
Detergents" for the correct procedures.
WARNING RISK OF
INJECTION CAUSING
SEVERE INJURY!
-KEEP CLEAR OF NOZZLE!
NEVER PLACE HAND OR FIN-
GERS IN FRONT OF NOZZLE!
-DO NOT DIRECT DISCHARGE
STREAM AT PEOPLE OR PETS!
-BE CERTAIN THE NOZZLE IS
SECURELY CONNECTED TO
THE WAND TO PREVENT AN
ACCIDENTAL DISCHARGE!
OPERATING INSTRUCTIONS

Mi-T-M JP-Electric Operator's Manual 17
CLEANING WITH DETERGENTS:
1. Refer to "Detergent Cleaning Precautions" before working with detergents.
Be certain to wear protective safety attire as stated.
2. Prepare detergent solution according to label directions. Never pump
acids, alkaline, abrasive uids or solvents through the unit.
3. Connect your detergent hose to the unit as show on page 8; detergent
solution is determined as follows below depending on your model:
Figure A. Your injector is equipped with an adjustment knob on the
pump head, you may adjust the amount of detergent desired by
turning the knob completely counterclockwise to set at the maximum
siphon rate.
Figure B and C. The detergent ratio is preset and cannot be adjusted.
4. Immerse the detergent strainer into the detergent solution to allow
detergent to siphon.
5. With the trigger gun locked in the "OFF" position, adjust detergent
according to the "Nozzle Review Section" on page 13.
NOTE: This injection system is designed to apply detergents under
low pressure only. It will not allow detergent solutions to be intro-
duced into the system unless the detergent nozzle (6540 Black) is
installed.
6. To apply solution; unlock the trigger gun and squeeze the trigger. In a
few moments a detergent/water mixture will exit the low pressure nozzle.
Start spraying the lower portion of the surface being cleaned and move
up, using long overlapping strokes. Applying from the bottom up helps
avoid streaking. Allow to soak briey. DO NOT allow detergent solution
to dry on the surface. (Avoid working on hot surfaces or in direct sunlight
to minimize the chances of the detergent drying, which may result in
damaging painted surfaces.) Be certain to rinse a small section at a time.
7. To rinse; lock the trigger gun in the "OFF" position, either securely quick-
connect the desired high pressure nozzle into the end of the wand, or
adjust your nozzle according to the "Nozzle Review Section". Unlock
the trigger gun and spray. It will take about 30 seconds to purge all
detergent from the line. For best rinsing results, start at the top and
work down.
8. Siphon a gallon of water through the low pressure detergent injection
system after each use. This prevents the possibility of corrosion or
detergent residue causing mechanical problems during the next use.
SHUTDOWN:
1. Move the switch to the "OFF" position to turn unit off.
2. Turn the water supply off.
3. Pointing the gun in a safe direction, trigger the gun momentarily to relieve
any trapped pressure.
4. Once pressure is relieved, disconnect the nozzle.
5. Disconnect the unit from the power source.
6. Disconnect and drain gun, wand and hoses.
7. Wipe unit clean and store with gun, wand and hoses in a safe area.
FIGURE A. QUICK CONNECT
DETERGENT
FIGURE B. ADJUSTABLE NOZZLE
DETERGENT
FIGURE C. ADJUSTABLE NOZZLE
DETERGENT
OPERATING INSTRUCTIONS

18 Mi-T-M JP-Electric Operator's Manual
SPECIFIC MAINTENANCE:
PUMP: The pump oil must be changed after the rst 25 hours of operation.
Once the initial oil change has been completed, it is recommended the oil
be changed every 3 months or 250 hour intervals. If oil appears dirty or
milky, changes may be required at a greater frequency. Use Mi-T-M pump
oil #AW-4085-0016 and ll only to the center of the oil sight glass. DO NOT
OVERFILL!
NOZZLES: Water ow through the spray nozzle will erode the orice, making
it larger, resulting in a pressure loss. Nozzles should be replaced whenever
pressure is less than 85% of the maximum. The frequency of replacement
will depend upon such variables as mineral content in the water and number
of hours the nozzle is used.
QUICK COUPLERS (if applicable): There is an o-ring seal inside the female
quick coupler. This o-ring will deteriorate or, if the unit is allowed to pump
without the high pressure hose or nozzle attached, the o-ring may be blown
out occasionally. Simply insert a replacement o-ring to correct the leak. (Ad-
ditional o-rings can be purchased from your dealer.)
WINTERIZING:
For storage and transportation purposes in subfreezing ambient tempera-
tures, it will be necessary to winterize this unit. This unit must be protected
to the lowest incurred temperature for the following reasons:
1. If any part of the pumping system becomes frozen; excessive pressure may
build up in the unit which could cause the unit to burst resulting in possible
serious injury to the operator or bystanders.
2. The pumping system in this unit may be permanently damaged if frozen.
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below
32°F, you can protect your unit by following the procedure outlined below.
1. Gather the following items:
a. Two 5 gallon containers.
b. One gallon of antifreeze. (Mi-T-M recommends an environmentally safe
antifreeze.)
c. Water supply.
d. Three foot hose, 1/2-3/4 I.D. with a 3/4 inch male garden hose tting.
2. Procedure:
a. To start winterizing, unit must be run and primed according to the
"Start-up Procedures" listed on page 16.
b. After running and priming, shut off the unit and water supply.
c. Relieve system pressure by pointing the trigger gun in a safe direction
and squeezing the trigger until water ow ceases to exit the nozzle.
d. Lock the trigger gun in an OFF position and remove the nozzle.
e. Remove the water supply hose from the unit and attach the 3 foot hose
securely to the inlet connection.
f. Shut off the detergent injector if applicable.
g. Fill one 5 gallon bucket with water.
h. Holding the 3 foot hose in an upright position, completely ll the hose
with water. Then plug the hose outlet with your thumb or nger. Place
the plugged end into the 5 gallon bucket of water.
i. Turn the unit on. Trigger the gun several times until all the air is worked
out of the system (unit is primed).
STORAGE & MAINTENANCE
WARNING RISK OF UNIT
BURSTING!
DO NOT STORE OR OPERATE
UNIT IN A FREEZING ENVI-
RONMENT!
32˚F 0˚C

Mi-T-M JP-Electric Operator's Manual 19
STORAGE & MAINTENANCE
NOTE: Proper winterizing is based on the recommended manufacturer's
instructions listed on the "Protection Chart" shown on the back label
of most antifreeze containers.
j. With the trigger gun held open, siphon enough water out of the 5 gallon
bucket until there is just enough water left to mix with the antifreeze.
k. Point the wand into the empty container and start the unit.
l. Trigger the gun until the antifreeze begins to exit the wand. Release
the trigger for 3 seconds, then trigger the gun for 3 seconds. Continue
cycling the gun several times until all the antifreeze mixture is siphoned
from the container.
m. Detach the 3 foot hose from the unit and drain any excess antifreeze
back into the 5 gallon container.
n. Disconnect the hose/gun/wand assembly from the unit and drain any
excess antifreeze back into the 5 gallon container.
o. Store the hose, gun and wand with the unit in a safe area.
p. Store antifreeze solution for next use or dispose of according to state
EPA laws.
3. Optional Procedure:
a. Shut the unit off.
b. Relieve system pressure by pointing the trigger gun in a safe direction
and squeezing the trigger until water ow ceases to exit the nozzle.
c. Disconnect and drain the hose, gun and wand.
d. Start the unit and allow it to run until all the water exits the unit. Once
the water has stopped owing from the unit, turn off.
NOTE: When using this procedure, caution should be used as ice chips
can form from drops of water which could cause the unit to burst if
starting before completely thawed.
STARTING UNIT AFTER EXTENDED STORAGE:
1. BE CERTAIN the unit is NOT plugged into the power source.
2. Prior to restarting the unit, thaw out any possible ice from the wand, gun,
hose and unit.
3. After following all "PREPARATION" instructions, start the unit momentarily
and immediately turn "OFF" to ensure all parts are lubricated before
operation.

20 Mi-T-M JP-Electric Operator's Manual
SYMPTOM PROBABLE CAUSE REMEDY
Pump motor will not start, or
stops while operating.
GFCI tripped. Turn unit "OFF". Test GFCI by pressing
reset button
Loose or disconnected plug. Reconnect plug.
Circuit overload. Tripped circuit
breaker or fuse blown in circuit
fuse box.
Disconnect all other plugs on the circuit be-
ing used and reset circuit breaker OR check
and replace fuse.
Tripped circuit breaker in unit. Allow to cool and restart unit.
Motor overload. Reset thermal overload button on pump
motor or inside electrical control panel.
Unit is frozen. Allow to thaw. If any part of the unit be-
comes frozen; excessive pressuremay build
up in the unit which could cause the unit to
burst resulting in possible serious injury to
the operator or bystanders.
Circuit breaker trips or fuse
blows in the
Circuit overload. Ensure electrical supply is identical to the
specications listed on the pressure washer
data plate. Disconnect all plugs on the cir-
cuit. When connecting to a circuit protected
by fuses, use time delay fuses only.
Extension cord is too long or wire
is too small.
Electrical requirements on extension cord
should comply with thespecications listed
on the pressure washer data plate.
Too much pressure. Use Adjusting Knob on Unloader to reduce
pressure.
GFCI trips. Incorrect voltage. Ensure electrical supply is identical to the
specications listed on the pressure washer
data plate.
Electrical short to ground. Contact Customer Service
Motor runs but there is no dis-
charge at nozzle when trigger
mechanism is squeezed
Water supply is not turned on. Turn water supply completely on.
Kink in water inlet hose. Remove kink.
Kink in high pressure discharge
hose
Replace hose
Low or uctuating pressure. Water inlet screen obstructed. Remove screen, clean or replace.
Pump sucking air. (Prime lost) Tighten all water intake connections. Elimi-
nate leaks in intake line.
Not in high pressure mode. Insert high pressure nozzle.
Obstructed or worn orice. Remove and clean, or replace.
Damaged or obstructed valve
assembly on pump.
Remove, clean or replace.
Pump packings worn. Replace packings.
Unloader valve not operating
correctly.
Repair or replace.
Water is leaking from Thermal
relief Valve.
Water inlet temperature is too
high.
Incoming water temperature must be less
than 140°.
Water temperature in unit is too
high.
Do not allow unit to operate in bypass mode
(with the trigger gun closed) for more than
three minutes.
Defective valve. Defective valve.
TROUBLESHOOTING

Mi-T-M JP-Electric Operator's Manual 21
SYMPTOM PROBABLE CAUSE REMEDY
Water is leaking from Thermal
relief Valve
Water inlet temperature is too
high
Incoming water temperature must be less
than 140°.
Water temperature in unit is too
high.
Do not allow unit to operate in bypass mode
(with the trigger gun closed) for more than
three minutes.
Defective valve. Replace
Oil appears milky or foamy. Water in oil. Change pump oil. Fill to proper level.
Oil leaking from unit. Worn seals or o-rings. Contact Customer Service.
Detergent will not siphon into
Low Pressure Detergent mode.
Detergent strainer is not com-
pletely submerged in detergent
solution
Check; submerge if necessary.
Detergent strainer is obstructed. Inspect, clean or replace
Detergent hose is obstructed, cut
or kinked
Inspect, clean or replace.
Detergent adjusting knob turned
to the closed position.
Open adjusting knob.
Not in Low Pressure mode. Insert 6540° (BLACK) nozzle.
Nozzle assembly is plugged. Clean or replace.
Too many high pressure hose
extensions attached to the water
outlet.
Use one extension maximum.
Ball & Spring in detergent strainer
stuck.
Remove, clean or replace.
Water ows back into detergent
container.
Ball & Spring in Venturi reversed,
missing or corroded.
Remove, clean or replace.
Water ows from the nozzle
when the trigger gun is in the
"OFF" position.
Gun is malfunctioning. Repair or replace.
TROUBLESHOOTING

22 Mi-T-M JP-Electric Operator's Manual
ACCESSORIES
15-0006 Supply Hose ¾ in.
50-0195 Hose Reel 13 in. (Holds 100 ft. of Hose)
851-0338 3000 PSI Extension Hose 50 ft.
AW-3000-XXXX Sandblaster Carbide Nozzle (Consult Factory)*
AW-4085-0016 Pump Oil 16 oz.
AW-7003-XXXX Rotary Brush (Consult Factory)*
AW-7018-XXXX Extension Wand (Consult Factory)*
AW-7103-XXXX Extension Wand (Consult Factory)*
AW-7300-XXXX Rotating Nozzle (Consult Factory)*
*PSI and GPM must be specied when ordering.
Mi-T-M All Purpose Cleaner, Paint Surface Prep, House and Deck Wash, and Heavy Duty
Degreaser are specially formulated detergents for use with all Mi-T-M pressure washers
and are packaged in one (1), ve (5), and fty-ve (55) gallon containers. Contact Mi-T-M
Customer Service Department at (800) 553-9053 for more information.

Mi-T-M JP-Electric Operator's Manual 23
STATEMENT OF WARRANTY
Mi-T-M warrants all parts, (except those referred to below), of your new pressure washer to be free from
defects in materials and workmanship during the following periods:
For Five (5) Years from the date of original purchase:
High Pressure Pump
For Two (2) Years from the date of original purchase:
Cart Assembly
Plumbing
For One (1) Year from the date of original purchase:
GFCI Selector Switch
For Ninety (90) days from the date of original purchase:
Trigger Gun/Wand High Pressure Hose
Unloader Valve Strainer/lter
Defective parts not subject to normal wear and tear will be repaired or replaced at our option during the
warranty period. In any event, reimbursement is limited to the purchase price paid.
EXCLUSIONS
1. The motor is covered under separate warranty by its respective manufacturer and is subject to the terms
set forth therein.
2. Normal wear parts:
Pump Packings Spray Nozzles
Pump Valves Detergent Valves
Quick Couplings/Screw Connects O-rings
3. This warranty does not cover parts damaged due to normal wear, misapplication, misuse, operation
at other than recommended speeds, pressures or temperature. Parts damaged or worn because of
the use of caustic liquids or by operation in abrasive or corrosive environments or under conditions
causing pump cavitation are not warranted. Failure to follow recommended operating and maintenance
procedures also voids warranty.
4. The use of other than genuine Mi-T-M repair parts will void warranty. Parts returned, prepaid to our
factory or to an Authorized Service Center will be inspected and replaced free of charge if found to be
defective and subject to warranty. There are no warranties which extend beyond the description of the
face hereof. Under no circumstances shall Mi-T-M bear any responsibility for loss of use of the unit,
loss of time or rental, inconvenience, commercial loss or consequential damages.
For Service or Warranty Consideration, contact Customer Service.
563-556-7484 / 800-553-9053 / Fax 563-556-1235
Monday - Friday 8:00 a.m. - 5:00 p.m. CST

24 Manual del Operador
ADVERTENCIA: Este producto puede
exponerlo a productos químicos, incluido el
plomo, que el Estado de California conoce a
causar cáncer y defectos congénitos u otros
daños reproductivos. Para obtener más
información, visite www.P65Warnings.ca.gov
ADVERTENCIA
TABLE OF CONTENTS
INTRODUCCION ...........................................................................................................25
ADVERTENCIAS DE SEGURIDAD ...............................................................................26
PRECAUCIONES ELECTRICAS: .............................................................................................................26
PRECAUCIONES PARA ROCIADO..........................................................................................................27
PRECAUCIONES MISCELANEAS DE SEGURIDAD ................................................................................27
PRECAUCIONES PARA LIMPIEZA CON DETERGENTES ......................................................................29
ELEMENTOS Y COMPONENTES ....................................................................... 30 & 32
CALCOMANIAS DE SEGURIDAD Y UBICACION .............................................. 31 & 33
INSTALACION Y PREPARACION .................................................................................34
PROTECCIÓN PERSONAL: .....................................................................................................................34
PREPARACIÓN: ....................................................................................................................................... 34
CONEXIÓN DEL CABLE DE ALIMENTACIÓN ELÉCTRICA: ....................................................................34
BOQUILLA DE REPASO: (2503 Y 3004): ................................................................................................35
BOQUILLA DE REPASO: .........................................................................................................................36
CONEXION DE LA BOQUILLA:................................................................................................................36
SUMINISTRO DE AGUA: .........................................................................................................................36
DESCARGADOR: .....................................................................................................................................37
VALVULA DE DESCARGA TERMICA: ......................................................................................................37
PROCEDIMIENTOS DE INSPECCION DE PREARRANQUE: ..................................................................37
INSTRUCCIONES DE OPERACION .............................................................................39
CEBADO DE LA BOMBA: ....................................................................................................................... 39
ARRANQUE: ............................................................................................................................................39
LIMPIEZA CON DETERGENTES .............................................................................................................40
APAGADO: ............................................................................................................................................... 41
ALMACENAMIENTO Y MANTENIMIENTO .................................................................42
MANTENIMIENTO ESPECIFICO:.............................................................................................................42
PREPARACION PARA EL INVIERNO: ...................................................................................................... 42
ARRANQUE DE LA UNIDAD DESPUES DE UN ALMACENAMIENTO PROLONGADO: ......................... 43
LOCALIZACION DE FALLAS ........................................................................................ 44
ACCESSOIRES ..............................................................................................................46
NOTA ..............................................................................................................................47
DECLARACIÓN DE GARANTÍA ...................................................................................49

Manual del Operador 25
INTRODUCCION
¡Felicitaciones por la compra de su nueva lavadora a presión Job Pro®! Puede estar seguro que su lavadora a
presión Job Pro® fue construida con el nivel más alto de precisión y exactitud. Cada componente ha sido probado
rigurosamente por técnicos para asegurar la calidad, la resistencia y el rendimiento de esta unidad.
Este manual del operador fue compilado para su benecio. Leyendo y siguiendo los pasos simples de seguridad,
instalación, operación, mantenimiento y localización de fallas descritos en este manual ayudará a prolongar aun más
la operación libre de fallas que usted puede esperar de su nueva lavadora a presión Job Pro. El contenido de este
manual está basado en la información actualizada disponible al momento de la publicación. Mi-T-M® se reserva el
derecho de efectuar cambios en precio, color, materiales, equipo, especicaciones o modelos en cualquier momen-
to sin previo aviso.
¡IMPORTANTE!
ESTOS PÁRRAFOS ESTÁN RODEADOS POR UNA “CASILLA DE ALERTA DE SEGURIDAD”. ESTA
CASILLA SE USA PARA DESIGNAR Y ENFATIZAR LAS ADVERTENCIAS DE SEGURIDAD QUE DEBEN
SEGUIRSE AL OPERAR ESTA LAVADORA A PRESIÓN. ACOMPAÑANDO A LAS ADVERTENCIAS
DE SEGURIDAD ESTÁN LAS “PALABRAS DE ALERTA” QUE DESIGNAN EL GRADO O NIVEL DE
SERIEDAD DE RIESGO. LAS “PALABRAS DE ALERTA” USADAS EN ESTE MANUAL SON LAS
SIGUIENTES:
PELIGRO: INDICA UNA SITUACIÓN INMINENTE RIESGOSA LA CUAL, SI NO SE EVITA, RESULTARA EN
LA MUERTE O EN LESIONES GRAVES.
ADVERTENCIA: INDICA UNA SITUACIÓN POTENCIALMENTE RIESGOSA LA CUAL, SI NO SE EVITA,
PODRIA RESULTAR EN LA MUERTE O EN LESIONES GRAVES.
PRECAUCION: INDICA UNA SITUACIÓN POTENCIALMENTE RIESGOSA LA CUAL, SI NO SE EVITA
PUEDE RESULTAR EN LESIONES MENORES O MODERADAS.
EL SÍMBOLO INDICADO A LA IZQUIERDA DE ESTE PÁRRAFO ES EL “SÍMBOLO DE ALERTA
DE SEGURIDAD”. ESTE SÍMBOLO SE USA PARA ALERTARLO ACERCA DE ARTÍCULOS O
PROCEDIMIENTOS QUE PODRÍAN SER PELIGROSOS PARA USTED U OTRAS PERSONAS USANDO
ESTE EQUIPO.
PROVEA SIEMPRE UNA COPIA DE ESTE MANUAL A CUALQUIER PERSONA QUE USE ESTE EQUIPO.
LEA TODAS LAS INSTRUCCIONES ANTES DE OPERAR ESTA LAVADORA A PRESION, OBSERVANDO
EN PARTICULAR LAS “ADVERTENCIAS DE SEGURIDAD” PARA EVITAR LA POSIBILIDAD DE
LESIONES PERSONALES AL OPERADOR.
Escriba el número de serie de su unidad en el espacio provisto abajo, una vez que la unidad haya sido desempaca-
da.
NUMERO DE SERIE___________________________
Inspeccione por daño el contenido de la caja. Si algo parece dañado, NO LA DEVUELVA AL LUGAR DE COMPRA.
Llame a su representante de servicio al cliente de al 800-553-9053.
Por favor tenga disponible la información siguiente para todas las llamadas de servicio:
1. Número de modelo
2. Número de serie
3. Fecha y lugar de compra
Mi-T-M
®
Corporation
50 Mi-T-M Drive
Peosta, IA 52068-0050

26 Manual del Operador
PRECAUCIONES ELECTRICAS:
RIESGO DE DESCARGA ELÉCTRICA O ELECTROCUCIÓN
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES
CORPORALES GRAVES O LA MUERTE SI NO SE CONECTA
ADECUADAMENTE A TIERRA LA LAVADORA DE CHORRO
A PRESIÓN. LA UNIDAD TRABAJA MEDIANTE ENERGÍA
ELÉCTRICA Y PUEDE CAUSAR UNA DESCARGA ELÉCTRICA O
ELECTROCUCIÓN SI NO SE USA DEBIDAMENTE.
1. Este producto debe estar conectado a tierra. Asegúrese de que la lavadora de
chorro a presión esté equipada con un GFCI (interruptor accionado por falla de
conexión a tierra). Si no lo tiene, la lavadora debe conectarse en un receptáculo
protegido por un GFCI. Desconecte la unidad cuando no esté usándose.
2. Si la unidad está equipada con GFCI, NO deje caer éste, ya que podría dañarse.
Si se deja caer por accidente el GFCI, asegúrese de probarlo para asegurarse de
que trabaja correctamente. (Para el procedimiento de prueba, siga las instrucciones
indicadas en el GFCI.)
3. Siempre asegúrese de que la unidad reciba el voltaje adecuado. Desconéctela
cuando no esté usándose.
4. No modique la clavija eléctrica. Si no entra en la toma de corriente, permita que un
electricista calicado instale una toma adecuada. No use ningún tipo de adapatador.
ADVERTENCIA EL CORDÓN ELÉCTRICO PUEDE CAUSAR UNA
DESCARGA ELÉCTRICA.
5. Revise el cordón eléctrico y vea si muestra señales de aplastamiento,
cortaduras o daños de origen térmico. Si es necesario cambiar la clavija o
el cordón, use exclusivamente piezas de repuesto idénticas.
6. No use cordones de extensión con esta lavadora de chorro a presión.
7. Mantenga secas y lejos del piso todas las conexiones. No permita que los
cordones eléctricos estén en agua o en tal posición que el agua entre en
contacto con ellos. No toque la clavija con las manos húmedas.
8. No tire del cordón eléctrico para desconectarlo de la toma de corriente.
ADVERTENCIA SI NO SE OPERA DEBIDAMENTE LA LAVADORA
DE CHORRO A PRESIÓN PUEDE OCURRIR UNA DESCARGA
ELÉCTRICA.
9. NO dirija el chorro sobre ni dentro de instalaciones eléctricas de ninguna clase,
como tomas de corriente, focos (bombillos), cajas de fusibles, transformadores, la
unidad misma, etc.
10. NO permita que ningún componente metálico de la lavadora de chorro a
presión entre en contacto con elementos electrizados.
11. Nunca utilice la lavadora a presión con las guardas o tapas desmontadas o dañadas.
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES CORPORALES
GRAVES O LA MUERTE SI PERSONAS NO CALIFICADAS
INTENTAR EFECTUAR REPARACIONES DE TIPO ELÉCTRICO.
12. Toda conexión o reparación efectuada en la lavadora de chorro a presión
debe ser realizada por el personal de servicio autorizado, de conformidad
con los códigos eléctricos locales y nacionales.
13. Antes de abrir cualquier compartimiento eléctrico, siempre apague la
lavadora de chorro a presión, purgue la presión y desconecte de la línea
de suministro de voltaje la lavadora. Permita a la lavadora enfriarse. Nunca
suponga que es seguro trabajar en la lavadora simplemente porque no está
funcionando. ¡Puede arrancar en cualquier momento! Dele servicio en un
área limpia, seca y plana.
ADVERTENCIAS DE SEGURIDAD

Manual del Operador 27
PRECAUCIONES PARA ROCIADO
PELIGRO RIESGO DE INYECCIÓN O CORTADURA GRAVE
MANTÉNGASE ALEJADO DE LA BOQUILLA. NUNCA APUNTE
EL CHORRO A ALTA PRESIÓN A SÍ MISMO NI A NADIE
MÁS. DEBEN OBSERVARSE SIEMPRE LAS PRECAUCIONES
BASICAS, INCLUYENDO LAS SIGUIENTES:
1. Manténgase alejado de la boquilla y del chorro a presión. Nunca coloque
la mano, dedos o cuerpo directamente en la boquilla de rociado.
2. Nunca apunte el chorro a alta presión a sí mismo ni a nadie más.
3. Este producto sólo debe emplearse por operarios capacitados.
4. Siempre mantenga el área de trabajo despejada de personas.
5. NO permita a los niños manejar esta unidad.
6. BUSQUE ASISTENCIA MÉDICA si el chorro parece haber penetrado la
piel! ¡NO LO TRATE COMO UNA SIMPLE CORTADA!
7. Las mangueras de alta presión y conductos de combustible deben
inspeccionarse diariamente para ver si muestran señales de desgaste. Si
muestran señales evidenes de falla, cámbielos de inmediato para evitar
toda posibilidad de lesiones causadas por el chorro a alta presión. Si
tiene fugas una manguera o adaptador, NUNCA COLOQUE LA MANO
DIRECTAMENTE EN LA FUGA.
8. NUNCA opere la pistola con el gatillo en la posición abierta. Para evitar
toda descarga accidental, el gatillo debe bloquearse cuando no esté
usándose la pistola.
9. No tire de la manguera para mover la unidad.
10. Antes de desmontar la boquilla de rociado o de dar servicio a la unidad,
SIEMPRE apague ésta y tire del gatillo para liberar toda presión atrapada.
(Incluso después de apagar la unidad, hay alta presión acumulada en la
bomba, manguera y pistola hasta que la libere tirando del gatillo.)
11. NO deje desatendida la unidad si tiene presión. Apague la lavadora y
libere toda presión acumulada antes de retirarse.
PRECAUCIONES MISCELANEAS DE SEGURIDAD
RIESGO DE EXPLOSIÓN O INCENDIO ADVERTENCIA PUEDEN
PRODUCIRSE LESIONES CORPORALES GRAVES O LA
MUERTE DEBIDO AL CHISPEO NORMAL PRESENTE EN
LAS DIFERENTES FUENTES DE MOTOR Y SISTEMA DE
ELECTRICA.
1. Siempre use la lavadora en un área bien ventilada libre de emanaciones
inamables, polvo combustible, gases y cualquier material combustible.
2. ¡No use esta lavadora para rociar material inamable!
RIESGO DE ASFIXIA:
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES CORPORALES
GRAVES O LA MUERTE SI SE INHALAN LAS EMANACIONES
PROVENIENTES DEL OTRAS EMANACIONES PELIGROSAS.
1. Siga todas las instrucciones de seguridad suministradas con los materiales
a los que esté rociando. Puede ser necesario tener puesta una mascarilla
de respiración para trabajar con ciertos materiales. No use esta lavadora
de chorro a presión para aplicar detergentes peligrosos.
ADVERTENCIAS DE SEGURIDAD

28 Manual del Operador
RIESGO DE REVENTÓN:
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES GRAVES SI
FUNCIONA MAL LA LAVADORA O SI EXPLOTAN ACCESORIOS,
EN CASO DE USARSE COMPONENTES, ADITAMENTOS O
ACCESORIOS INADECUADOS.
1. Nunca haga ajustes a las presiones jadas en la fábrica.
2. Nunca se exceda de las presión nominal máxima permitida por el fabricante
de los aditamentos.
3. Use solamente piezas de repuesto recomendadas por el fabricante para
la lavadora.
ADVERTENCIA PUDEN PRODUCIRSE LESIONES GRAVES O LA
MUERTE SI SE INTENTA ARRANCAR LA LAVADORA CUANDO
ESTÁ CONGELADO EL SISTEMA DE BOMBEO DE LA UNIDAD.
4. A temperaturas de congelación, la unidad siempre debe estar a la suciente
temperatura para evitar la formación de hielo en la bomba. No arranque la
lavadora si ha sido transportada en un vehículo abierto o a baja temperatura
sin permitir calentarse primero al sistema de bombeo de la unidad.
RIESGO DE MOVIM. DE PZAS:
ADVERTENCIA PUEDEN CAUSARSE LESIONES GRAVES AL
OPERARIO CON LAS PIEZAS MÓVILES DE LA LAVADORA.
1. Nunca haga ajustes a la unidad mientras esté conectada a la línea de
suministro de voltaje.
2. No opere la unidad sin las tapas protectoras puestas en su lugar.
3. Para dar servicio a la unidad, colóquela en un área limpia, seca y plana. Antes de
darle servicio a la unidad, apáguela, alivie la presión de la pistola y permita enfriarse
a la unidad.
4. Siga las instrucciones de mantenimiento especicadas en el manual.
RIESGO DE LESIONES:
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES POR LA
BASURA IMPULSADA A ALTA VELOCIDAD POR LA PISTOLA DE
ROCIADO.
1. SIEMPRE póngase gafas protectoras al operar la unidad para protegerse
los ojos de la basura que sale despedida y detergentes.
2. NO dirija el chorro hacia materiales frágiles como el vidrio ya que pueden
romperse.
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES SI EL OPERARIO
PIERDE EL EQUILIBRIO O DEBIDO AL EMPUJE DEL AGUA AL
CIRCULAR POR LA BOQUILLA DE ROCIADO.
1. Permanezca alerta de lo que está haciendo. No maneje la unidad si está
fatigado o bajo los efectos del alcohol o drogas.
2. NUNCA accione el gatillo si no lo tiene bien abrazado con el dedo. NO extienda
el cuerpo demasiado ni se pare en una base inestable. Las supercies
húmedas pueden estar resbalosas; póngase equipo antirresbalante en los
pies, párese en forma sólida y mantenga un buen equilibrio.
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES POR LA
LAVADORA DE CHORRO A PRESIÓN.
1. SIEMPRE sostenga rmemente el conjunto de la pistola y la caña al arrancar
y operar la unidad. De lo contrario la caña puede caer y dar chicotazos
peligrosamente.
2. Sepa bien cómo detener la lavadora de chorro a presión y cómo purgar
las presiones con rapidez. Familiarícese bien con los controles.
ADVERTENCIAS DE SEGURIDAD

Manual del Operador 29
PRECAUCIONES PARA LIMPIEZA CON DETERGENTES
RIESGO DE LESIONES:
ADVERTENCIA PUEDEN PRODUCIRSE LESIONES O LA MUERTE SI
LOS DETERGENTES LLEGAN A TOCAR LA PIEL.
1. Nunca use ningún solvente, detergentes corrosivos ni limpiadores de tipo
ácido con esta lavadora de chorro a presión.
2. Esté preparado para indicarle al doctor la clase de detergentes que estaba
aplicando; para ello, lea la hoja de datos de seguridad del material (MSDS)
correspondiente al detergente.
3. Se recomienda ponerse equipo protector como traje de hule, guantes y
mascarilla de respiración, especialmente al aplicar detergentes.
4. ¡Mantenga todo detergente fuera del alcance de los niños!
! GUARDE ESTES INSTRUCCIONES !
ADVERTENCIAS DE SEGURIDAD

30 Manual del Operador
ELEMENTOS Y COMPONENTES
1. Acoples Rapidos Boquilla
2. Conjunto del la pistola
3. GFCI
4. Calcomanía-Advertencia: Riesgo de
electroccución
5. Manguera de descarga de alta presión
6. Válvula de descarga térmica
7. Salida de agua
8. Entrada de agua
9. Tamiz de entrada de agua
10. Tamiz de detergente
11. Manguera de detergente
12. Vidrio de nivel de aceite
13. Bomba
14. Perilla ajustable del descargador
15. Calcomania-Advertencia: Riesgo de
Inyección/Explosién
16. Interruptor On/Off
17. Calcomanía-Declaraciones de Precaucio-
narias
LISTA DE LOS ELEMONTOS Y COMPONENTES
JP-SM-ELECTRIC FEATURES 070522

Manual del Operador 31
CALCOMANIAS DE SEGURIDAD Y UBICACION
No retire las calcomanias de seguridad de la unidad a menos que las reemplace por las calcomanias de seguridad
mas recientes!
CAUTION / PRECAUCION
IMPORTANT / IMPORTANTE
1. Read operator's manual
carefully before using.
2. Spray gun can kick back.
Hold with both hands.
3. Risk of eye injury. Always
wear eye protection.
4. See the operator's manual
for proper chemical usage.
1. Lea cuidadosamente el manual del
operador antes de usar.
2. El revolver rociadora puede
retroceder violentemente. Sujétela
con ambas manos.
3. Riesgo de lesiones a los ojos. Use
siempre protección para los ojos.
4. Para un uso químico apropiado
consulte el Manual del Operador.
CONNECT TO AN
INDIVIDUAL BRANCH
CIRCUIT ONLY.
• For indoor and outdoor use.
• Store indoors.
• Avoid pump damage.
Protect from freezing. Do
not run for more than 3
minutes with spray gun not
triggered.
• If connected to a circuit
protected by fuses, use
time-delay fuses marked D.
• Para uso interior y exterior.
• Almacene bajo techo.
• Evite daños a la bomba. Protéjala
contra la congelación. No haga
funcionar por más de 3 minutos
sin accionar el gatillo de la pistola.
• Si le raccordement se fait á un
cicuita protégé par fusibles,
utiliser un fusible temporisé
marqué D.
RIESGO DE LESIONESRISK OF INJURY
34-1015/080912
CONECTAR SOLAMENTE
A UN CIRCUITO
DERIVADO INDIVIDUAL.
RISK OF INJECTION OR SEVERE INJURY
Never put your hand, fingers or body directly
over the spray nozzle.
34-1253/07272012
RIESGO DE INYECCIÓN O LESIÓN SEVERA
Nunca coloque la mano, los dedos o el cuerpo
directamente sobre la boquilla de rocío.
WARNING
ADVERTENCIA
CAUTION
PRECAUCION
34-1254/051322
Hot discharge fluid. Do not
touch or direct discharge
stream at people.
Pump surface temperature
is same as inlet water
temperature.
180°F maximum water inlet
temperature.
Descarga de caliente.¡No
dirija el chorro de descarga
hacia personas. De
temperatura del superficie la
bomba como lo mismo
entrada de temperatura del
agua.
Entrada de temperatura del
agua la máximo 180°F.
WARNING ADVERTENCIA
RISK OF EXPLOSION: Do not
spray flammable liquids.
RISK OF ELECTROCUTION: Do
not spray electrical apparatus
and wiring.
RISK OF INJECTION OR
SEVERE CUTTING INJURY:
Keep clear of nozzle. Do not
direct discharge stream at persons.
RISQUE D'EXPLOSION: Ne pas pulvériser
de liquides inflammables.
RISQUE D'ÉLECTROCUTION: Ne pas
vaporiser sur des appareils et des fils
électriques.
RISQUE D'INJECTION OU DE COUPURES
GRAVES: Rester à l’écart de la buse. Ne
jamais diriger le jet vers des personnes
ou soi-même.
RIESGO DE EXPLOSI
ÓN
: No
rocie liquidos inflamables.
RIESGO DE ELECTROCUCIÓN:
No rocíe el aparato y el cableado
eléctricos.
RIESGO DE INYECCI
ÓN O LESIÓN
DE CORTE
: Manténgase alejado de la
boquilla. No dirija la corriente de descarga
hacia las personas.
34-4125/062322
AVERTISSEMENT
WARNING / ADVERTENCIA
34-2796/071019
RISK OF ELECTROCUTION. DO NOT REMOVE THIS TAG.
WARNING: Cancer and Reproductive Harm —
www.P65warnings.ca.gov/
1. Connect only to a properly grounded outlet. Do not remove
ground pin.
2. Inspect cord before using. Do not use if cord is damaged.
3. Keep all connections dry and off the ground.
4. Do not touch plug with wet hands.
5. This product is provided with a Ground Fault Circuit
Interrupter (GFCI) built into the power cord plug. If
replacement of plug or cord is needed, use only identical
replacement parts.
6. Do not use an extension cord with this machine.
7. Read the operator's manual before using.
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS
COULD RESULT IN A SEVERE ELECTRICAL SHOCK.
RIESGO DE ELECTROCUCION. NO RETIRE ESTA CALCOMANIA.
ADVERTENCIA: Peligro de cáncer y daño reproductivo —
www.P65warnings.ca.gov/
1. Conecte solamente a un tomacorriente apropiadamente conectado a
tierra. No retire la clavija de conexion a tierra.
2. Antes de usar inspeccione el cordon. si el cordon esta dañado no la
use.
3. Mantenga todas las conexiones secas y alejadas del suelo.
4. No toque el enchufe con las manos mojadas.
5. Este producto viene con un interruptor de circuito de falla de
conexion a tierra (GFCI) incorporado al enchufe del cordon
electirco. Use solo piezas identicas de repuesto si se necesita un
reemplazo del enchufe o del cordon.
6. No use un cordon de extension con esta maquina.
7. Antes de usar lea el manual del operador.
EL NO SEGUIR LAS INSTRUCCIONES DE ARRIBA PUEDE
RESULTAR EN UN CHOQUE ELECTRICO GRAVE.
34-4126/062322
WARNING
If connection is made to
a potable water system,
the system shall be
protected against backflow.
Si la conexión se hace a un
sistema de agua potable, el
sistema será protegido contra
la expulsión.
Si l'appareil est raccordé à un
réseau d'eau potable, il doit
être protégé contre les
refoulements.
ADVERTENCIA AVERTISSEMENT
34-1068/080912
IMPORTANT/IMPORTANTE
Do not operate
without water.
Do not use
water that is
over 125°F.
No se opere sin agua.
No se use con agua
con temperaturas de
mas de 52 °C.

32 Manual del Operador
ELEMENTOS Y COMPONENTES
1. Sobrecarga del motor
2. Calcomanía-Advertencia/Precaucion/Operacion
3. Motor
4. Calcomanía: Riesgo de inyección/explosión
5. Bomba
6. Tamiz de detergente
7. Manguera de detergente
8. Perilla ajustable del descargador
9. Botón ajustable
10. Tamiz de entrada de agua
11. Calcomania: Advertencia: Agua potable
12. Salida de agua
13. Manguera de descarga de alta presión
14. Interruptor On/Off
15. Calcomanía: Riesgo de inyección/explosión
16. Cordón eléctrico
17. GFCI
18. Etiqueta-Advertencia: Riesgo de electrocución
19. Conjunto del la pistola
20. Calcomania: Riesgo de inyección
21. Acoples Rapidos Boquilla
LISTA DE LOS ELEMONTOS Y COMPONENTES
JP-LG-ELECTRIC-FEATURES 040422

Manual del Operador 33
CALCOMANIAS DE SEGURIDAD Y UBICACION
No retire las calcomanias de seguridad de la unidad a menos que las reemplace por las calcomanias de seguridad
mas recientes!
34-1471/081712
RISK OF ELECTROCUTION. DO NOT REMOVE THIS TAG.
FAILURE TO FOLLOW THE ABOVE INSTRUCTIONS
COULD RESULT IN A SEVERE ELECTRICAL SHOCK.
RIESGO DE ELECTROCUCION. NO RETIRE ESTA CALCOMANIA.
EL NO SEGUIR LAS INSTRUCCIONES DE ARRIBA PUEDE
RESULTAR EN UN CHOQUE ELECTRICO GRAVE.
ADVERTENCIA
WARNING
1.Conecte solamente a una toma corriente que está bien fundado. No
quite la pata de conexión de la tierra.
2. Antes de usar inspeccióne la cuerda. No use si la cuerda està dañando.
3. Mantenga los conexiones secos y apar tados de la tierra.
4.No torque el enchufe con manos mojados.
5.Este producto debe conectarse a tierra. Asegúrese de que la lavadora
a presión esté equipada con un Interruptor de circuito de falla a tierra
(Ground Fault Circuit Interrupter, GFCI) incorporado en el cordón de
alimentación. Si no lo tiene, debe conectarse la lavadora a presión
únicamente en un receptáculo que esté protegido por un Interruptor de
circuito de falla a tierra. Desconéctela cuando no esté en uso.
6.No use una cuerda extensión con la unidad.
7.Antes de usar lea y entienda todas las instrucciónes y el manual de
operación.
1.Connect only to a properly grounded outlet. Do not remove ground pin.
2.Inspect cord before using. Do not use if cord is damaged.
3.Keep all connections dry and off the ground.
4.Do not touch plug with wet hands.
5.This unit may be provided with a Ground Fault Circuit Interrupter (GFCI)
built into the power cord plug. If replacement of the plug or cord is
needed, use only identical replacement parts. If this unit is not provided
with a GFCI, this unit should only be connected to a power supply
receptacle protected by a ground fault circuit interrupter.
6.Do not use an extension cord with this machine.
7.Read the operator's manual before using.
CAUTION
PRECAUCION
34-1254/051322
Hot discharge fluid. Do not
touch or direct discharge
stream at people.
Pump surface temperature
is same as inlet water
temperature.
180°F maximum water inlet
temperature.
Descarga de caliente.¡No
dirija el chorro de descarga
hacia personas. De
temperatura del superficie la
bomba como lo mismo
entrada de temperatura del
agua.
Entrada de temperatura del
agua la máximo 180°F.
WARNING ADVERTENCIA
RISK OF EXPLOSION: Do not
spray flammable liquids.
RISK OF ELECTROCUTION: Do
not spray electrical apparatus
and wiring.
RISK OF INJECTION OR
SEVERE CUTTING INJURY:
Keep clear of nozzle. Do not
direct discharge stream at persons.
RIESGO DE EXPLOSI
ÓN
: No
rocie liquidos inflamables.
RIESGO DE ELECTROCUCIÓN:
No rocíe el aparato y el cableado
eléctricos.
RIESGO DE INYECCI
ÓN O LESIÓN
DE CORTE
: Manténgase alejado de la
boquilla. No dirija la corriente de descarga
hacia las personas.
34-1017/080612
RISK OF INJECTION OR SEVERE INJURY
Never put your hand, fingers or body directly
over the spray nozzle.
34-1253/07272012
RIESGO DE INYECCIÓN O LESIÓN SEVERA
Nunca coloque la mano, los dedos o el cuerpo
directamente sobre la boquilla de rocío.
WARNING
ADVERTENCIA
34-1477/080612
WARNING/ADVERTENCIA
If connection is made to
a potable water system,
the system shall be
protected against backflow.
Si la conexión se hace a un
sistema de agua potable, el
sistema será protegido
contra la expulsión.
34-1068/080912
IMPORTANT/IMPORTANTE
Do not operate
without water.
Do not use
water that is
over 125°F.
No se opere sin agua.
No se use con agua
con temperaturas de
mas de 52 °C.
CAUTION
1. Read operator's manual carefully before
using.
2. Spray gun can kick back. Hold with both
hands.
3. Risk of eye injury. Always wear eye protection.
4. See the operator's manual for proper
chemical usage.
1. Lea cuidadosamente el manual del operador antes de usar.
2. El revolver rociadora puede retroceder violentemente.
Sujétela con ambas manos.
3. Riesgo de lesiones a los ojos. Use siempre protección
para los ojos.
4. Para un uso químico apropiado consulte el Manual del
Operador.
IMPORTANT
• For indoor and outdoor use.
• Store indoors.
• Avoid pump damage. Protect from freezing.
Do not run for more than 3 minutes with
spray gun not triggered.
• If connected to a circuit protected by fuses,
use time-delay fuses only.
• Para uso interior y exterior.
• Almacene bajo techo.
• Evite daños a la bomba. Protéjala contra la congelación.
No haga funcionar por más de 3 minutos sin accionar el
gatillo de la pistola.
• Si se conecta a un circuito protegido por fusibles, use
fusibles con retardo solamente.
RIESGO DE LESIONESRISK OF INJURY
34-4058/111821
PRÉCAUTION
IMPORTANT

34 Manual del Operador
INSTALACION Y PREPARACION
PROTECCIÓN PERSONAL:
Ponerse la protección personal adecuada es vital para la propia seguridad.
Se recomienda utilizar lo que sea necesario para protegerse los ojos, oídos y
piel. Es posible que se necesite aditamentos adicionales de seguridad (como
la mascarilla de respiración) al aplicar agentes limpiadores detergentes con
esta lavadora.
PREPARACIÓN:
1. Esta unidad sólo debe colocarse en una supercie a nivel para asegurar
una lubricación adecuada de la bomba de agua durante el funcionamiento.
NUNCA rocíe agua directamente en la unidad.
2. No use la unidad en áreas:
a. donde existan señales de fugas de aceite o combustible.
b. donde pueda haber presencia de vapores de gases inamables.
3. No exponga la unidad a la lluvia, nieve o temperaturas de congelación. Si
se congela alguna parte de la unidad, puede acumularse presión excesiva,
la cual puede causar que reviente la unidad y se produzcan lesiones graves
al operador y a los circunstantes.
4. Debe revisarse el nivel de aceite de la bomba. Asegúrese de que el aceite llegue
a la marca de "lleno" de la vara de nivel o del centro de la mirilla de nivel del
aceite. Si parece bajo el nivel, llene el tanque con aceite para bomba Mi-T-M
#AW-4085-0016.
PELIGRO RIESGO DE
EXPLOSION!
NO COLOQUE LA UNIDAD EN
UN AREA DONDE PUEDAN
ESTAR PRESENTESE VA-
PORES INFLAMMABLES. UNIA
CHISPA PODRIA CAUSAR UNA
EXPLOSION.
RIESGO QUE LA UNIDAD REVI-
ENTE! NO ALMACENE/OPERE
LA UNIDADA EN U ABIENTE
HELADO.
PELIGRO ¡RIESGO DE
ELECTROCUCIÓN!
ESTA UNIDAD DEBE CONEC-
TARSE A UNA TOMA DE
CORRIENTE CON LA DEBIDA
CONEXIÓN A TIERRA. NO USE
NINGÚN ADAPTADOR NI ELIMI-
NE EL CONTACTO DE TIERRA.
ADVERTENCIA ¡RIESGO DE
ELECTROCUCIÓN!
PARA REDUCIR EL RIESGO DE
ELECTROCUCIÓN, MANTEN-
GA TODAS LAS CONEXIONES
SECAS Y LEJOS DEL PISO. NO
TOQUE LA CLAVIJA CON LAS
MANOS HÚMEDAS.
CONEXIÓN DEL CABLE DE ALIMENTACIÓN ELÉCTRICA:
1. El interruptor debe estar en la posición de apagado (OFF).
2. La fuente de voltaje debe ser idéntica a las especicaciones indicadas en
la placa de datos de la lavadora.
3. INSTRUCCIONES DE CONEXIÓN A TIERRA: Este producto debe estar
conectado a tierra. Si algo funciona mal o se descompone, la conexión a
tierra suministra un trayecto eléctrico de baja resistencia para la corriente
y así se reduce el riesgo de una descarga eléctrica. Este producto dispone
de cordón eléctrico con conductor a tierra para equipo. La clavija debe
enchufarse en una toma de corriente adecuada que esté instalada y
conectada a tierra según todos los códigos y reglamentos locales.
4. PELIGRO: Una conexión inadecuada del conductor a tierra para equipo
puede originar un riesgo de electrocución. Consulte con un electricista o
técnico de servicio calicados si no está seguro que la toma está conectada
a tierra adecuadamente. No modique la clavija; si no encaja bien en la
toma de corriente, permita que un electricista calicado instale una toma
correcta. No use ningún tipo de adaptador con este producto.
5. PROTECCIÓN DE INTERRUPTOR ACCIONADO POR FALLA DE CONEXIÓN
A TIERRA:
a. MONOFÁSICA: Si esta lavadora de chorro a presión cuenta con GFCI
(interruptor accionado por falla de conexión a tierra) integrado en la
clavija o en el cordón de alimentación eléctrica, pruebe el GFCI cada
vez que la conecte a una toma, siguiendo las instrucciones del mismo.
¡NO use la lavadora si el circuito no pasa la prueba! El GFCI proporciona
protección adicional contra el riesgo de descargas eléctricas. Si es
necesario cambiar la clavija o el cordón, sólo use piezas de repuesto
idénticas y que incluyan la protección de un GFCI.
b. MONOFÁSICA: Si esta lavadora de chorro a presión no cuenta con
GFCI, sólo debe conectarse en un receptáculo protegido por GFCI
(interruptor accionado por falla de conexión a tierra) para cumplir con
el Código Eléctrico Nacional (NFPA 70) y para proporcionar protección
adicional contra el rieso de descargas eléctricas.
c. TRIFÁSICA: Estas lavadoras no vienen con protección de GFCI.

Manual del Operador 35
6. CORDONES DE EXTENSIÓN: ¡Mi-T-M NO RECOMIENDA EL USO DE
CORDONES DE EXTENSIÓN! Si es inevitable el uso de un cordón de
extensión, debe conectarse a un GFCI de la caja de fusibles o receptáculo
con tal tipo de protección. Si va a usar un cordón de extensión, consulte a
un electricista calicado para determinar la calibre de conductor adecuado
necesario para la longitud del cordón de extensión.
MONOFÁSICA: Sólo use cordones de extensión de tres hilos y que tenga clavija
de conexión a tierra de tres puntas y conector para cordón de tres polos
que acepte la clavija del producto.
TRIFÁSICA: Sólo use cordones de extensión de cuatro hilos y conector para
cordón de cuatro polos que acepte la clavija del producto.
Sólo use cordones de extensión para uso exterior. Tienen el rótulo
"Aceptables para uso con aparatos de uso al aire libre; almacénese en
el interior cuando no esté en uso." Sólo use cordones de extensión con
especicaciones eléctricas superiores a las del producto. No use cordones
de extensión dañados. Examine el cordón de extensión antes de usarlo y
cámbielo si está dañado. No trate en forma abusiva el cordón de extensión
ni tire del mismo para desconectarlo. Mantenga el cordón alejado del calor
y de bordes alados. Siempre conecte o desconecte el cordón de extensión
del receptáculo antes de conectar o desconectar el producto del cordón
de extensión.
7. Debe manterse seca el área existente entre la lavadora de chorro a presión
y la toma de corriente.
8. Inserte la clavija en una toma de corriente alterna (CA). ¡¡NO use adaptadores
NI retire la clavija de conexión a tierra!!
BOQUILLA DE REPASO: (2503 Y 3004):
Pueden conectarse rápidamente varias boquillas al extremo de la vara para
cambiar el patrón de rociado o para usar la característica de detergente.
Asegúrese que la conexión está seguramente calzada, al usar los conec-
tores rápidos (C.R.). En caso contrario el agua a alta presión puede des-
pedir la boquilla de la vara, causando lesiones graves o daños importantes.
Reérase al número estampado en la boquilla, para determinar el patrón de
abanico del rociado. Los primeros dos dígitos indican el patrón de abanico
del rociado en grados, por ej.: 00=0°, 15=15º, 25=25º, 65=detergente/baja
presión.
1. Boquilla de 0º (ROJA): Esta es una boquilla de disparo que emite una
corriente muy concentrada de agua. Debería ejercerse cuidado para evitar
rayar la madera o dañar supercie frágiles. Usos: eliminación de malas
hierbas de las grietas de las aceras, manchas resistentes del concreto,
mampostería, aluminio y acero, lodo endurecido en equipos, y para limpiar
el fondo de las cortadoras de césped.
2. Boquilla de 15º (AMARILLA): Esta es una boquilla biselada. El rociado
debería dirigirse a un ángulo de 45º sobre la supercie y usarse como
un raspador para sacar pintura, grasa y suciedad. Usos: preparación de
supercies (eliminación de manchas de moho y escamas de pintura).
3. Boquilla de 25º (VERDE): Esta es una boquilla de limpieza por descarga de
agua. Este patrón es más apropiado para limpiar suciedad, lodo, y hollín.
Usos: Barrido en mojado de senderos, cordones de las aceras y entradas
de garages, limpieza de suelos de los establos, lavado de los fondos de
las piscinas de natación, desengrasado de motores.
4. Boquilla de 65º (NEGRA): Esta es una boquilla de aplicación de detergente,
de baja presión. Este patrón de rociado amplio distribuye la solución sobre
áreas amplias a baja presión. Usos: Aplicación de detergente, como rociado
o enjuague.
ADVERTENCIA ¡RIESGO DE
INYECCION CAUSANTE
DE LESIONES GRAVES!
¡NUNCA MIRE DIRECTAMENTE
AL ORIFICIO DE LA BOQUILLA
A MENOS QUE ESTE DE-
SCONECTADO DEL CONJUN-
TO DE LA PISTOLA/VARA!
CONEXION DE LAS BOQUILLAS
DE CONEXION RAPIDA
BOQUILLAS DE CONEXION RAPIDA
(C.R.)
INSTALACION Y PREPARACION
ILUSTRACIÓN A. BOQUILLA AJUSTABLE
BAJA PRESIÓN / DETERGENTE
CUBIERTA DE BOQUILLA
ALTA PRESIÓN
CUBIERTA DE BOQUILLA
BAJA PRESION / DETERGENTE
CUBIERTA DE BOQUILLA
CUBIERTA DE BOQUILLA
ALTA PRESION

36 Manual del Operador
ADVERTENCIA ¡RIESGO DE
LESIONES GRAVES!
¡CUANDO NO SE USA, LA PISTO-
LA A GATILLO DEBERIA ESTAR
SIEMPRE ASEGURADO EN LA
POSICION DESCONECTADO!
REVISE EL COLADOR DE ENTRADA
DE AGUA
INSTALACION Y PREPARACION
BOQUILLA DE REPASO:
NOTA: Dependiendo de su modelo, hay dos variaciones diferentes
para ajustar la boquilla. Asamblea de boquilla no debería conec-
tarse a la asamblea de pistola a este tiempo.
Variación 1 (Ver ilustración A)
1. Las selecciones de alta y baja presión pueden lograrse tirando de la cubierta
de la boquilla al extremo de la vara “HACIA” usted para la graduación
de Alta Presión y empujando la cubierta de la boquilla “ALEJADA” de
usted para Baja Presión y aplicación del detergente.
2. El patrón de rociado puede ajustarse de 0º a 65º girando la cubierta de la
boquilla al extremo de la vara hacia la derecha y hacia la izquierda. Ejerza
precaución al usar la corriente estrecha recta. No se recomienda para
usar en supercies pintadas o de madera, o artículos jados mediante
respaldos adhesivos.
Variación 2 (Ver ilustración B)
1. Seleción de presión alta puede obtener por doblando el cuello protectivo
en un dirección de las agujas del reloj como vea en dibujo técnico 1,
ilustración A. Mientras en modo de presión alta, el agua está directado
solamente por una boquilla de rociado de 15° haciendo un rociado
"abanico" concentrado de presión alta.
2. Seleción de aplicación de detergente de presión baja puede obtener por
doblando el cuello ensentido contrario como vea en dibujo técnico 2,
ilustración B. izquierda. Cuando presión está bastante baja, la inyectadora
en limpiadora de presión traerá detergente entre el sistemo. Como el
cuello está doblado, una mezcla de agua/detergente existe de boquilla
de rociado y alrededor de la boquilla. Este empieza un combinación un
patron de rociado de "abanico/cono".
CONEXION DE LA BOQUILLA:
1. Asegúrese que la pistola a gatillo esté asegurada en la posición "OFF"
(DESCONECTADO). Vea la ADVERTENCIA, a la derecha.
2. La asamblea de boquilla no debe conectar de la asamblea de pistola
en este tiempo como la asamblea de boquilla / lanza de la asamblea de
pistola / lanza. Retraiga el anillo de cierre sobre el adaptador de conexión
rápida para sacar la boquilla ilustración O por destornillar la boquilla /
conjunto lanza de la pistola /conjunto de lanza (ver ilustración B).
SUMINISTRO DE AGUA:
1. Seleccione una manguera de suministro de agua que sea de calidad de
manguera de jardín que mida 3/4" de DI por lo menos y que no sea más
larga que 50 pies.
2. Inspeccione el tamiz de entrada de agua para asegurar que esté limpio y
libre de obstrucciones. La limpieza periódica del tamiz de agua ayudará
a prevenir problemas con la bomba. El tamiz restringe el ujo apropiado
de agua a la bomba, a medida que se obstruye. Esto puede resultar en
cavitaciones que causarán la falla prematura de los empaques de las
bombas.
a. Retire el tamiz de la unidad, usando un destornillador.
Drawing 2
Drawing 1
ILUSTRACIÓN B.
BOQUILLA AJUSTABLE
CONECTE
RACOR DE CONEXIÓN RÁPIDA
DISCONECTADO
ILUSTRACIÓN A ILUSTRACIÓN B

Manual del Operador 37
b. Si fuera necesario, limpie o reemplace con la Pieza No.19-0001 de
Mi-T-M.
3. Connect la mangureras:
a. Conecte un extremo de la manguera de suministro de agua a la entrada
de agua de la unidad.
b. Conecte el otro extremo de la manguera a su suministro presurizado
de agua.
NOTA: No use un suministro de agua no presurizado (por ej. agua de
pozo o estanque) con esta unidad.
c. Efectúe la conexión de la manguera de descarga de alta presión a la
salida de agua de la unidad.
4. Siga los requerimientos de agua entrante listados abajo:
a. La presión de agua debe estar a un mínimo de 40 libras por pulgada
cuadrada (PSI) y un máximo de 125 PSI. (Un grifo típico al aire libre
suministrará generalmente estas PSI si está completamente ABIERTO).
b. Los GPM (galones por minuto) entrantes deben ser ser 1 galón más
aproximadamente que los GPM salientes deben indicados en la placa
de nombre de la lavadora a presión. (Usted puede inspeccionar los
GPM observando el tiempo requerido para llenar un recipiente de 5
galones.)
c. La temperatura del agua de entrada no debe exceder 140°F. Si la
unidad está equipada con un kit de embalaje en caliente (modelos
2ME1 solamente), la temperatura no puede exceder hasta 190 ° F (87
° C). Puede resultar un daño excesivo a la bomba si la temperatura del
agua excede este nivel aceptable.
5. Nunca permita que la unidad opere sin que esté conectada la tubería de
agua de entrada y el suministro de agua completamente abierto.
DESCARGADOR:
Usted puede ajustar la presión, si el descargador de su máquina está equi-
pado con una perilla de ajuste. Si se requiere menos presión, simplemente
gire la perilla de ajuste en sentido contrario a las agujas del reloj. Para retor-
nar al máximo, gire completamente la perilla de ajuste en el sentido de las
agujas del reloj. ¡NO AJUSTE EN EXCESO!
VALVULA DE DESCARGA TERMICA:
Nunca permita que la lavadora a presión opere en el modo de derivación durante
más de tres minutos (con la unidad funcionando y la pistola a gatillo cerrado),
para asegurar que la temperatura del agua no exceda niveles aceptables.
Se ha agregado una válvula de descarga térmica a esta unidad para proteger la
bomba. Puede comenzar a abrirse y permitir la salida de agua si la temperatura
del agua en la bomba ha excedido los 140°F. Esto permitirá que agua fresca
y fría entre al sistema.
PROCEDIMIENTOS DE INSPECCION DE PREARRANQUE:
Efectúe los procedimientos siguientes antes de arrancar la unidad:
1. Inspeccione los cordones electricos para cortes. Si encuentre unos cortes,
NO TOQUÉ NI USE CORDÓN! Antes de arrancar reponza el cordon.
2. Inspeccione el nivel de aceite en la bomba y en el motor.
3. Inspeccione el tamiz de entrada de agua. Limpie o reemplace si fuera
necesario. Vea “Suministro de agua”, #2, pág. 37.
4. Inspeccione todas las conexiones de las mangueras para asegurar que
estén bien ajustadas. Vea “Suministro de agua”, #3, pág. 37.
5. Inspeccione por pérdidas de combustible del sistema. Asegúrese que se
reemplacen todas las piezas dañadas y que se corrijan todos los problemas
INSTALACION Y PREPARACION
PRECAUCION ¡RIESGO DE
DAÑO A LA UNIDAD!
NO AJUSTE EN EXCESO EL
DESCARGADOR. LA ROTURA
RESULTARA EN UNA PERDIDA
INMEDIATA DE PRESION DE
AGUA Y REPARACIONES COS-
TOSAS.

38 Manual del Operador
FINAL DE LAS INSTRUCCIONES DE PREPARACION
ADVERTENCIA
LAS PAGINAS SIGUIENTES CONTIENEN INSTRUCCIONES DE OPERACION Y MANTENIMIENTO
NO TRATE DE OPERAR ESTA LAVADORA A PRESION HASTA QUE HAYA LEIDO Y ENTENDIDO TODAS
LAS PRECAUCIONES E INSTRUCCIONES DE SEGURIDAD LISTADAS EN ESTE MANUAL.
¡¡LA OPERACION INCORRECTA DE ESTA UNIDAD PUEDE CAUSAR LESIONES GRAVES!!
¡¡DE NINGUNA MANERA ALTERE O MODIFIQUE ESTE EQUIPO!!
mecánicos antes de operar la unidad. Consulte con el Servicio al Cliente
de Mi-T-M, si usted requiere servicio.
6. Inspeccione las mangueras de alta presión por dobleces, cortes y pérdidas.
Asegúrese que se reemplacen todas las piezas dañadas y que se corrijan los
problemas mecánicos antes de operar la unidad. Consulte con el Servicio
al Cliente de Mi-T-M, si usted requiere servicio.
INSTALACION Y PREPARACION

Manual del Operador 39
CEBADO DE LA BOMBA:
1. Es esencial cebar la bomba en el arranque inicial y cada vez que se
desconecta el suministro de agua de la unidad después del uso inicial.
2. Desplieque la manguera de alta presión para eliminar los dobleces. El ujo
de agua endurecerá la manguera, creando bucles rígidos si la manguera
no está recta.
NOTA: El conjecto de la boquilla NO debería conectarse al conjunto de la
pistola en este momento. Vea “Conexión de la boquilla”, pág. 36.
3. Abra completamente el suministro de agua, con la pistola a gatillo asegurado
en la posición “OFF”. Suelte el seguro de la pistola a gatillo y accione este
último, apuntando la pistola en una dirección segura.
4. Comenzará a uir agua a baja presión del conjunto de manguera/pistola.
Esto permite que la unidad se cebe y purgue todo el aire del sistema. Esta
unidad está cebada cuando el ujo de agua no esté interrumpido por el
aire.
5. Suelte el gatillo y asegure la pistola en la posición “OFF”, una vez que la
unidad esté cebada. Conecte seguramente el conjunto de la boquilla.
(Vea "Conexión de la boquilla", pág. 36.)
ARRANQUE:
1. Reérase a las “Precauciones de seguridad”, págs. 26-29 antes de arrancar
la unidad.
2. Ubique las calcomanías de seguridad en su unidad y obedezca sus
advertencias.
3. Apunte la pistola a gatillo alejado de usted o de cualquier otra persona, con
el mismo asegurado en la posición “OFF”. Asegúrese que el suminstro de
agua esté completamente abierto.
4. Desenganche el seguro de la pistola y accione el gatillo. Comenzará a uir
agua a baja presión de la boquilla.
5. Afírmese ya que la pistola retrocederá violentamente a causa de la alta
presión causada por la bomba una vez que haya arrancado el motor.
6. Mueva el interruptor On/Off a la posición “ON”. En la unidad este interruptor
incluye un interruptor de circuitos para la protección del motor. El interruptor
de circuito moverá automáticamente el interruptor a la posición “OFF”,
en caso de carga excesiva. Para volver a arrancar, mueva nuevamente el
interruptor On/Off a la posición “ON”.
7. Efectúe los procedimientos siguientes una vez que haya arrancado el motor
con la pistola en la posición abierta:
a. Inspeccione por pérdidas de aceite y de agua del sistema. ¡APAGUE
INMEDIATAMENTE LA UNIDAD, si encuentra una pérdida! Antes de
operar la unidad, asegúrese que se hayan reemplazado todas las piezas
dañadas y que se hayan corregido todos los problemas mecánicos.
Consulte con el Servicio, si usted requiere servicio.
b. Inspeccione las mangueras de alta presión por dobleces, cortes y
pérdidas. ¡¡¡NO TOQUE LA MANGUERA EN LA PERDIDA, si encuentra
un corte o una pérdida!!! ¡APAGUE INMEDIATAMENTE LA UNIDAD!
Antes de arrancar nuevamente la unidad, reemplace la manguera.
Antes de operar la unidad, asegúrese que se hayan reemplazado todas
las piezas dañadas y que se hayan corregido todos los problemas
mecánicos. Consulte con el Servicio, si usted requiere servicio.
c. Inspeccione el cordón eléctrico por cortes. ¡NO TOQUE NI USE EL
CORDON ELECTORCO, si se halla un corte! Remplace el cordón
antes de arrancar la unidad. Consulte con el Servicio al Cliente si usted
requiere servicio.
8. ASEGURE la pistola a gatillo en la posición “OFF” siempre que cambie las
ADVERTENCIA ¡RIESGO DE
INYECCION CAUSANTE
DE LESIONES GRAVES!
¡MANTENGASE ALEJADO DE
LA BOQUILLA! ¡NUNCA COLO-
QUE LA MANO NI LOS DEDOS
ENFRENTE DE LA BOQUILLA!
¡NO DIRIJA LA CORRIENTE
DE DESCARGA HACIA LAS
PERSONAS O LOS ANIMALES
DOMESTICOS!
¡PARA PREVENIR UNA DES-
CARGA ACCIDENTAL ASE-
GURESE QUE EL CONJUNTO
DE LA BOQUILLA AJUST-
ABLE ESTE SEGURAMENTE
CONECTADO A LA VARA!
PRECAUCION RIESGO DE
DAÑO
NO DIRIJA CONTINUAMENTE
EL PATRON DE ROCIADO EN
UNA SECCION DE LA SUPER-
FICIE DURANTE UN PERIODO
PROLONGADO DE TIEMPO.
PUEDEN OCURRIR POSIBLES
DAÑOS.
INSTRUCCIONES DE OPERACION

40 Manual del Operador
boquillas de conexión rápida. ¡NUNCA mire directamente en la boquilla!
¡El agua a alta presión crea un riesgo de lesiones graves!
9. No permita que la unidad funcione en un modo de derivación (con el
gatillo cerrado) por más de tres minutos sin accionar el gatillo de la
pistola. El no seguir esta simple regla puede causar la falla prematura
de los sellos del empaque de la bomba, resultando en una reparación
costosa a la misma.
10. Puede haber muchas tareas de limpieza que pueden efectuarse sin el uso
de detergentes, a causa que la lavadora a presión suministra un rociado
a alta presión y una variedad de patrones de rociado. Vea “Limpieza con
detergentes”, pág. 39, para los procedimientos correctos, si se requiere
un agente de limpieza.
LIMPIEZA CON DETERGENTES
1. Reérase a las “Precauciones de limpieza con detergentes”, pág.
28. Asegúrese de usar vestimenta protectora de seguridad según lo
mencionado en la pág. 34.
2. Prepare la solución de detergente de acuerdo con las instrucciones del
rótulo. Nunca bombee ácidos, alcalinos, uidos abrasivos o solventes
a través de la unidad.
3. Conecte la inyectadora de detergente a la unidad como vea en pagiña
48. La solución de detergente se determina a continuación según su
modelo:
Ilustración A: De unidad están equipadas con un botón ajustable
sobre la bomba de presión, puded ajustar la cantidad de detergente
deseado, girando el botón completamente en contra de reloj, para
ajustar a razón de sifón máxima.
Ilustración B y C:La porporción de detergente está pregraduada en la
unidad y no puede ajustarse.
4. Sumerja el tamiz dentro de la solución del detergente para permitir que
este último circule por sifón.
5. Ajuste el detergente de acuerdo con "Sección de revisión de boquillas"
en la página 35, con la pistola a gatillo asegurado en la posición “OFF”.
NOTA: Este sistema de inyección está diseñado para aplicar deter-
gentes a baja presión solamente. No permitirá que se introduzcan
soluciones de detergente en el sistema a menos que la boquilla
del detergente esté instalada en la vara.
6. Desenganche la pistola a gatillo y accione el gatillo, para aplicar la
solución. Una mezcla de detergente/agua saldrá de la boquilla de baja
presión en unos pocos momentos. Comience rociando la porción inferior
de la supercie que está siendo limpiada y muévase hacia arriba usando
pasadas largas superpuestas. El aplicar desde abajo hacia arriba ayuda
a evitar el estriado. Permita que se empape brevemente. (Para minimizar
la posibilidad de que se seque el detergente, lo que puede resultar en
daños a las supercies pintadas, evite trabajar sobre supercies calientes
o bajo la luz directa del sol.) Asegúrese de enjuagar una sección pequeña
por vez.
7. Para enjuagar: asegure la pistola a gatillo en la posición “OFF”, y usando
el conector rápido, conecte seguramente la boquilla de alta presión al
extremo de la vara. Desenganche la pistola a gatillo y rocíe. Llevará 30
segundos aproximadamente purgar todo el detergente de la tubería.
Comience en la parte superior y trabaje hacia abajo, para obtener los
mejores resultados del enjuague.
8. Después de cada uso, extraiga por sifón un galón de agua del sistema
de inyección de detergente a baja presión. Esto evita la posibilidad de
corrosión o de que el residuo de detergente cause problemas mecánicos
durante el próximo uso.
ILUSTRACIÓN A. QUICK CONNECT DE-
TERGENT
ILUSTRACIÓN B. BOQUILLA AJUST-
ABLE PARA DETERGENTES
ILUSTRACIÓN C. BOQUILLA AJUSTABLE
PARA DETERGENTES
INSTRUCCIONES DE OPERACION

Manual del Operador 41
APAGADO:
1. Para apagar la unidad, mueva el interruptor On/Off a la posición “OFF”.
2. CIERRE el suministro de agua.
3. Accione momentáneamente el gatillo de la pistola para descargar toda
la presión interna, apuntando la pistola en una dirección segura.
4. Desconecte el conjllunto de la boquilla, una vez que se haya eliminado
la presión.
5. Desconecte la unidad de la fuente de potencia.
6. Drene la pistola, la vara y las mangueras. Desconecte las mangueras,
una vez drenado.
7. Limpie la unidad con un paño y almacene con la pistola, la vara y las
mangueras en un área segura.
INSTRUCCIONES DE OPERACION

42 Manual del Operador
MANTENIMIENTO ESPECIFICO:
BOMBA: El aceite de la bomba debe ser cambiado después de las primeras
25 horas de operación en todas las unidades. Se recomienda intervalos de
250 horas, después de la carga inicial. Pueden requerirse cambios con may-
or frecuencia, si el aceite parece sucio o lechoso. Use aceite para bombas
de Mi-T-M (Pieza No. AW-4085-0016) y llene sólo hasta la marca en el vidrio.
NO llene en exceso.
BOQUILLAS: El agua que uye a través de la boquilla de rociado de con-
exión rápida desgastará y agrandará el oricio, resultando en una pérdida
de presión. Deberían reemplazarse las boquillas siempre que la presión sea
menor que el 85% del máximo. La frecuencia de reemplazo dependerá de
tales variables tales como el contenido mineral en el agua y el número de
horas que se usa la boquilla.
ACOPLES RAPIDOS (si aplicable): Hay un sello del anillo en O dentro de
acople rápido hembra en la salida de agua de su unidad. Este anillo en O
se deteriorará, o se saldrá de lugar si se permite que la unidad bombee
sin la manguera de alta presión. Simplemente inserte un anillo de repuesto
para corregir la pérdida. (Pueden comprarse anillos en O adicionales de su
distribuidor).
PREPARACION PARA EL INVIERNO:
Será necesario preparar esta unidad para el invierno, para nes de Alma-
cenamiento y transporte en temperaturas ambiente inferiores al punto de
congelación. Esta unidad debe protegerse contra la temperatura más baja
incurrida por las siguientes razones:
1. Si se congela cualquier parte del sistema de bombeo puede acumularse una
presión excesiva en la unidad, lo que podría causar que la misma reviente
resultando en lesiones posibles graves al operador o a los observadores.
2. El sistema de bombeo de esta unidad puede resultar dañado
permanentemente si se congela. LOS DAÑOS POR CONGELACION NO
ESTAN CUBIERTOS POR LA GARANTIA.
Usted puede proteger su unidad siguiendo el procedimiento indicado abajo,
si debe almacenarla en un lugar donde la temperatura puede descender por
debajo de los 32°F.
1. Reúne los artículos siguientes:
a. Dos recipientes de 5 galones.
b. Un galón de anticongelante. (Mi-T-M recomienda un anticongelante
seguro para el medio ambiente.)
c. Suministro de agua.
d. Una manguera de tres pies de largo con un D.I. de 1/2-3/4 y con un
adaptador macho de manguera de jardín de 3/4 de pulgada.
2. Procedimiento:
a. Para comenzar a preparar su unidad para el invierno, la misma debe
hacerse funcionar y cebarse de acuerdo con los “Procedimientos de
Arranque” indicados en la página 36-37.
b. Apague la unidad y corte el suministro de agua, después de hacerla
funcionar y cebarla.
c. Elimine la presión del sistema apuntando la pistola a gatillo hacia una
dirección segura y accionando el gatillo hasta que el ujo de agua cese
de salir por la boquilla.
d. Asegure la pistola a gatillo en la posición OFF y retire la boquilla.
e. Retire la manguera de suministro de agua de la unidad y je seguramente
la manguera de 3 pies a la conexión de entrada.
f. Si fuera aplicable apague el inyector de detergente.
g. Llene con agua un balde de 5 galones.
ADVERTENCIA ¡RIESGO
QUE LA UNIDAD
REVIENTE!
¡NO ALMACENE/OPERE LA
UNIDAD EN UN AMBIENTE
HELADO!
32˚F 0˚C
ALMACENAMIENTO Y MANTENIMIENTO

Manual del Operador 43
ALMACENAMIENTO Y MANTENIMIENTO
h. Manteniendo la manguera de 3 pies en una posición vertical, llénela
completamente con agua. A continuación tapone la salida de la
manguera con su dedo pulgar u otro dedo. Coloque el extremo
taponado dentro del balde de agua de 5 galones.
i. Arranque la unidad. Accione varias veces el gatillo de la pistola hasta
que todo el aire haya salido del sistema (la unidad está cebada).
j. Por medio de la acción de sifón extraiga suciente agua del balde de
5 galones hasta que haya justo suciente agua restante para mezclar
con el anticongelante, con la pistola a gatillo mantenido abierto.
NOTA: La preparación apropiada para el invierno está basada en las
instrucciones recomendadas del fabricante incluidas en la “Tabla
de Protección” mostrada en el rótulo posterior de la mayoría de los
recipientes de anticongelantes.
k. Apunte la vara hacia el recipiente vacío.
l. Accione el gatillo de la pistola hasta que el anticongelante comience a
salir por la vara. Suelte el gatillo por 3 segundos, a continuación accione
el gatillo de la pistola por 3 segundos. Continúe ciclando la pistola
varias veces hasta que toda la mezcla anticongelante es extraída del
recipiente por la acción de sifón.
m. Separe la manguera de 3 pies de la unidad y drene todo el exceso
restante de anticongelante dentro del reciente de 5 galones.
n. Desconecte el conjunto de manguera/pistola/vara de la unidad y drene
todo el exceso restante de anticongelante dentro del recipiente de 5
galones.
o. Almacene la manguera, la pistola y vara junto con la unidad, en un
lugar seguro.
p. Almecene la solución anticongelante para un uso ulterior o descártela
de acuerdo con las leyes de protección del medio ambiente
correspondientes.
3. Procedimiento opcional:
a. Apague la unidad y corte el suministro de agua.
b. Elimine la presión del sistema apuntando la pistola a gatillo hacia una
dirección segura y accionando el gatillo hasta que el ujo de agua cese
de salir por la boquilla.
c. Desconecte y drene la manguera, la pistola y la vara.
d. Arranque la unidad y permita que funcione hasta que toda el agua
salga de la misma. Apague una vez que el agua ha cesado de uir de
la unidad.
NOTA: Debe ejercerse precaución al usar este procedimiento, ya que
pueden formarse plaquitas de hielo de las gotas de agua, lo que
podría causar que la unidad reviente si se arranca antes de estar
completamente descongelada.
ARRANQUE DE LA UNIDAD DESPUES DE UN
ALMACENAMIENTO PROLONGADO:
1. ASEGURE que la unidad NO esté enchufada a la fuente de potencia.
2. Derrita todo el hielo eventual de la vara, la pistola, la manguera y la unidad,
antes de arrancar la unidad.
3. Arranque la unidad momentáneamente y apáguela inmediatamente para
asegurarse que todas las piezas están lubricadas antes de la operación,
después de seguir todas las instrucciones de “PREPARACION”.

44 Manual del Operador
SINTOMA CAUSA PROBABLE SOLUCION
El motor de la bomba no arran-
ca o sestops while operating.
apaga durante el funcionamien-
to.
GFCI activado o no se volvió a
ajustar.
Apague la unidad. Oprima el botón dereset
button reposición del GFCI después que se
ha enchufado a la fuente eléctrica.
Enchufe ojo o desconectado. Vuelva a conectar el enchufe.
Interruptor de circuito activado
o circuito quemado en la caja de
fusibles.
Desconecte todos los otros enchufes del
circuito que está siendo usado y reponga
el interruptor de circuito o inspeccione y
reemplace el fusible.
Interruptor de circuito activado
en la unidad.
Permita que la unidad se enfríe vuelva a
arrancar.
Sobrecarga del motor. Restablezca el botón de sobrecarga térmica
del motor de la bomba o dentro del tablero
de control eléctrico.
La unidad están congelados. Permita que se descongele. Si alguna parte
de sla unidada se condgela, es posible
que se acumule la presión, lo cual podría
ocasionar que la unidad reviente y conse-
cuentement provoque lesiones graves al
operador o las personas que se encuentren
alrededor.
Se activa el interruptor de cir-
cuito o se quema el fusible en la
caja de fusibles.
Sobrecarga del circuito. Verique que el circuito esté clasicado a
15 amperios o más.Desconecte todos los
enchufes en el circuito.
El cordón de extensión es de-
masiado largo o el conductor es
demasiado pequeño.
Observe los requerimientos eléctricos cor-
rectos indicados.
Demasiada presión. Reduzca la presión usando la perilla de
ajuste de presión.
Se activa el GFCI. Voltaje incorrecto. Asegúrese que el suministro eléctrico sea de
120 Voltios/15 Amperios/60 Hertz/Monofási-
co.
Corto circuito interno. Consulte con el Centro de Servicio.
El motor funciona pero no hay
descarga en la boquilla cuando
se acciona el mecanismo del
gatillo.
Suministro inadecuado de agua. Asegure que la manguera tenga ¾” de
diámetro y que este abierto el suministro de
agua entrante.
Doblez en la manguera de entra-
da de agua.
Elimine el doblez.
Doblez en la manguera de discar-
gade alta presión.
Reemplace la manguera.
Presión baja o uctuante. Está obstruido el tamiz de la
entrada de agua.
Retire el ltro, limpie o reemplace.
La bomba absorbe aire (elimina-
do elcebado).
Ajuste todas las conexiones de toma de
agua. Elimine pérdidas en la línea de toma.
No está en el modo de alta
presión.
Para enganchar el modo de alta presión, tire
de la cubierta de la boquilla hacia la pistola.
Oricio obstruido o gastado. Retire y limpie, o reemplace.
La válvula de derivación no está
funcionando correctamente.
Repárelos o cámbielos.
Empaques de la bomba des-
gastados.
Cambie los empaques.
El descargador o la válv. de des-
viación no trabajan bien.
Repárelos o cámbielos.
LOCALIZACION DE FALLAS

Manual del Operador 45
SINTOMA CAUSA PROBABLE SOLUCION
Fuga de agua en la válv. de
desc. térm.
Temp. de la entr. de agua muy
alta.
La temp. del agua de entr. debe ser inferior
a 140° F (52° C).
Temperatura del agua muy alta. No deje a la unidad trabajar en modo de
desviación (con la pistola cerrada) más de 5
minutos.
Válvula defectuosa. Cámbiela.
Aceite lechoso o espumoso. Hay agua en el aceite. Cambie el aceite de la bomba. Llénela al
nivel adecuado.
Fuga de aceite en la unidad. Sellos o aros tóricos desgasta-
dos.
Hable al dep. de servicio al cliente.
El detergente no uirá por sifón
en el modo de detergente a baja
presión.
El tamiz de detergente no está
completamente sumergido en la
solución de detergente.
Inspeccione; sumerja si fuera necesario.
El tamiz del detergetne está
obstruido.
Inspecciona, limpie o reemplace.
La manguera de detergente está
obstruida o cortada.
Inspecciona, limpie o reemplace.
Perilla de ajuste de deterg. está
en la posición cerrada.
Abra la perilla.
No está en el modo de baja
presión.
Inserte la boquilla 6540° (NEGRA).
La boquilla del detergente está
taponado.
Limpie o reemplace.
Hay demasiadas extensiones de
lasmangueras de alta presión
conectadas a la salida de agua.
Use una extensión como maximo.
Están atascados la bolilla y el
resorte del Venturi.
Retire, limpie o reemplace.
El ujo de agua retrocede al
recipiente del detergente.
La esfera y el resorte en el Venturi
están invertidos, faltano están
desgastados.
Saque, limpie o reemplace.
Cuando la pistola de gatillo está
asegurado en la posición "OFF",
el agua uye desde la boquilla.
La pistola funciona mal. Repárelos o cámbielos.
LOCALIZACION DE FALLAS

46 Manual del Operador
ACCESSOIRES
15-0006 Manguera de alimentación de 3/4"
50-0195 Carrete para la manguera 100'
851-0338 Manguera de extensión de 50' de 3000 PSI
851-0006 Manguera de extensión de 50' de 4000 PSI
AW-3000-XXXX Correador de arena-Punte de carburo (Llame el Servicio al Cliente)*
AW-4085-0016 Petroleo de bomba
AW-7003-XXXX Cepilla giratora (Llame el Servicio al Cliente)*
AW-7018-XXXX Vara de extensión (Llame el Servicio al Cliente)*
AW-7103-XXXX Vara de extensión de (Llame el Servicio al Cliente)*
AW-7300-XXXX Boquilla giratoria (Llame el Servicio al Cliente)*
*Se debe especicar presión (PSI) y volumen (GPM) al hacer el pedido.
Detergentes de Mi-T-M son detergentes expecialmente para usar con lavadoras a presion
de Mi-T-M y estan envasando en dimensiones varios. Para mas llame lose servicios para
clientes a 800-553-9053.

Manual del Operador 47
NOTA

48 Manual del Operador
NOTA

Manual del Operador 49
DECLARACIÓN DE GARANTÍA
Mi-T-M
®
Corporation garantiza que todas las piezas (excepto aquellas a las que se hace referencia abajo), de su nueva
lavadora a presión Job Pro
®
Series Cestán libres de defectos en materiales y mano de obra durante los periodos
siguientes:
Por un (5) años a partir de la fecha original de compra:
Bomba de Alta Presión
Por dos (2) años a partir de la fecha original de compra:
Unidad Base Tuberías
Por una (1) años a partir de la fecha original de compra:
GFCI Enciende/apaga la luz
Por noventa (90) días a partir de la fecha original de compra:
Manguera de alta Presión Pistola de Gatillo
Válvulas de descargador Filtro
Las piezas defectuosas que no están sujetas a deterioro causado por el uso serán reparadas o reemplazadas a
nuestra opción durante el periodo de garantía. En todo caso, el reembolso está limitado al precio de compra pagado.
EXCLUSIONES
1. El motor está cubierto bajo una garantía separada proporcionada por el fabricante respectivo y está sujeta a los
términos en ella establecidos.
2. Partes de desgaste normal:
Empaques de las Bombas Válvulas de la Bomba
Boquillas Válvulas del Detergente
Círculo Connexión Rapida
3. Esta garantía no cubre las piezas dañadas debido al deterioro normal causado por el uso, mala aplicación, mal
uso, operación a velocidades, presiones o temperaturas diferentes a las recomendadas. Las piezas dañadas o
gastadas a causa del uso de líquidos cáusticos o por la operación en medios ambientes abrasivos o corrosivos o
bajo condiciones que causan cavitación de la bomba no están garantizadas. La falla en seguir los procedimientos
recomendados de operación y mantenimiento también cancela la garantía.
4. El uso de piezas de repuesto diferentes a las genuinas Mi-T-M cancelará la garantía. Las piezas devueltas, con
franqueo pagado a un Centro de Servicio Autorizado Mi-T-M serán inspeccionadas y reemplazadas, libre de cargos,
si se determina que están defectuosas y sujetas a la garantía. No existen garantías que se extiendan más allá de
la descripción contenida aquí. Bajo ninguna circunstancia Mi-T-M
®
Corporation será responsable por la pérdida de
uso de la unidad, pérdida de tiempo, inconvenientes, pérdida comercial o daños consecuentes.
PARA SERVICIO O CONSIDERACION DE LA GARANTIA CONSULTE CON:
Mi-T-M
®
Corporation/50 MI-T-M Drive, Box 50/Peosta, IA 52068-0050
Telefono: 319-556-7484/Telefone gratis en los EE. UU.: 800-553-9053/Fax 319-556-1235
Lunes - Viernes 8:00 a.m. - 5:00 p.m. CST

50 Manual del Operador