background
MRCOOL®
Electric Storage Water Heater
INSTALLATION & OWNER’S MANUAL
Read this manual carefully before installation and keep it where
the operator can easily nd it for future reference.
Due to updates and constantly improving performance, the
information and instructions within this manual are subject to
change without notice.
Version Date: August 12, 2025
Please visit www.mrcool.com/documentation
to ensure you have the latest version of this manual.
MTWH045*E
MTWH045*EL
MTWH045*ET
MODELS:
background
mrcool.com1
CONTENTS
SAFETY ................................................................................................................ 2
INSTALLATION................................................................................................ 5
2.1 Location Selection .................................................................................... 5
2.2 Shipment Inspection ................................................................................ 5
2.3 Thermal Expansion .................................................................................. 5
2.4 Water Supply Connections ...................................................................... 6
2.5 Typical Installation ................................................................................... 6
2.6 Relief Valve ............................................................................................... 7
2.7 Filling the Water Heater .......................................................................... 7
2.8 Condensation ........................................................................................... 7
2.9 Energy Cover ............................................................................................. 7
2.10 Electrical Connections ........................................................................... 8
2.11 Energy Eciency ..................................................................................... 9
2.12 Hot & Cold Pipe Insulation Installation ................................................ 9
2.13 Relief Valve Insulation Installation ..................................................... 10
POST-INSTALLATION ................................................................................ 10
3.1 Installation Checklist ............................................................................. 10
3.2 Operating the Water Heater ................................................................. 10
3.3 Water Temperature Settings ................................................................ 11
3.4 Draining the Water Heater ................................................................... 12
3.5 Routine Preventative Maintenance ..................................................... 12
3.6 Extended Shut Down ............................................................................. 12
3.7 Anode Rod ............................................................................................... 12
3.8 Grounding ............................................................................................... 13
3.9 Troubleshooting ..................................................................................... 13
3.10 Replacement Parts ............................................................................... 14
3.11 Service Needs ....................................................................................... 15
3.12 Wiring Diagram .................................................................................... 15
1
Contents
2
3
background
mrcool.com 2 2
Incorrect usage may cause serious damage or injury.
The symbols below are used throughout this manual to indicate instructions that should be
followed closely or actions that should be avoided to prevent death, injury, and/or property
damage.
Safety Precautions
CAUTION
Indicates the possibility of personal injury or loss of life.
Indicates the possibility of property damage or serious
consequences.
Read Before Using
WARNING
SAFETY PRECAUTIONS
• The purpose of this manual is two fold: one, to provide the installer with the basic directions and
recommendations for the proper installation and adjustment of the water heater; and two, for the owner-
operator, to explain the features, operation, safety precautions, maintenance, and troubleshooting of the
water heater. This manual also includes a parts list.
• It is imperative that all persons who are expected to install, operate, or adjust this water heater read these
instructions carefully so they may understand how to perform these operations. If you do not understand
these instructions or any terms within it, seek professional advice.
• Do not destroy this manual. Please read carefully and keep in a safe space for the future.
• Any questions regarding the operation, maintenance, service, or warranty of this water heater should be
directed to the seller from whom it was purchased.
• Inside this manual, you will nd many helpful hints on how to use and maintain your water heater
properly. Just a little preventative care on your part can save you a great deal of time and money over the
life of your water heater.
• You'll nd many answers to common problems in the Troubleshooting section. You may not need to call
for service at all.
• For your safety, the information in this manual must be followed to minimize the risk of re, explosion,
electric shock, or to prevent property damage, personal injury, or loss of life.
• Be sure to read and understand this entire manual before attempting to install or operate this water
heater. Pay particular attention to the safety instructions. Failure to follow these warnings could result in
serious bodily injury or death. Should you have problems understanding the instructions in this manual, or
have any questions, stop and get help from a qualied service technician, or the local electric utility service.
• Use this appliance only for its intended purpose as described in this manual.
• Be sure your appliance is properly installed in accordance with local codes and these instructions.
• DO NOT attempt to repair or replace any part of your water heater unless it is specically recommended.
• All other servicing should be referred to a qualied technician.
• DO NOT turn on the electrical supply or operate the unit unless it is completely full of water.
SAFETY
1
CALIFORNIA INSTALLATIONS:
• Proposition 65: This product contains chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
• California law requires that residential water heaters must be braced, anchored, or strapped to resist
falling or horizontal displacement due to earthquake motions. For residential water heaters up to 52 gallon
capacity, a brochure with generic earthquake bracing instructions can be obtained from: Oce of the State
Architect, 400 P Street, Sacramento, CA 95814. You may also call 916-324-5315 or ask a water heater dealer.
• Applicable local codes shall govern installation. For residential water heaters with a capacity greater than
52 gallons, consult the local building jurisdiction for acceptable bracing procedures.
background
mrcool.com3
SAFETY
1
WARNINGS
When using electrical appliances, basic safety precautions to reduce the risk of re, electric shock, or
injury to persons should be followed, including:
• Read all instructions before using this water heater.
• This water heater must be grounded. Connect only to a properly grounded outlet. See the "Grounding
Instructions" section in this manual.
• Install or locate this water heater only in accordance with the provided installation instructions.
• Use this water heater only for its intended use as described in this manual.
• Do not use an extension cord set with this water heater. If no receptacle is available adjacent to the water
heater, contact a qualied electrician to have one properly installed.
• As with any appliance, close supervision is necessary when used by children.
• Do not operate if the unit has a damaged cord/plug, is not working properly, or has been damaged or
dropped.
• This water heater should be serviced only by qualied service personnel. Contact your nearest authorized
service facility for examination, repair, or adjustment.
• Do not use volatile oil, alcohol, thinner, etc. to clean the machine, otherwise it may damage the product.
• The installation torque for the inlet and outlet water pipes must not exceed 36.8 lb.ft., otherwise it will
permanently damage the structure of the water heater.
• It is forbidden to modify the purpose and function of the product without permission.
• Before cleaning the machine or performing maintenance, disconnect the main power supply.
• If the machine is not used for a long time, please disconnect the main power supply.
• When not in use for a long time, or when the power is o in cold weather, the water must be drained.
• Do not place water containers on live products. Water seeps into the interior of the water heater and
weakens the insulation of the electrical appliances, causing electric shock, re, etc.
• The power supply must be within the specied voltage range of the product.
• Prevent children from entering the interior of the product.
• The safety precautions are clearly stated as hazard prevention matters.
• Do not install the unit around ammable and explosive products, in an environment with strong
electromagnetic interference, in an environment with an open ame, or a strong corrosive environment.
Also avoid places with safety hazards.
• If there are no independent power supplies, sockets, and other safety switches, do not install the unit.
• The main power supply of the equipment should be located in a place that is not easily accessible to
children and should be avoided from being blocked by ammable objects.
• When the installation involves drainage pipes, it must be ensured that the drainage can be done smoothly.
• Take precautions regarding the necessary strength and structure of the installation location (wall, ceiling,
etc.), the xing method of the fuselage, the method of use, and related precautions.
• The auxiliary materials used for installation must comply with local regulations.
• It is recommended to connect the rated specications of the wiring, the rated specications of the plug or
switch. If the diameter of the user's power cord is too small, it could lead to a risk of re. If the diameter of
the user's power cord is lower than the actual product's required diameter or the diameter does not meet
the total power load, it is prohibited to install the product.
• Before installation, it is necessary to check whether the user's home power supply has a ground wire. If it is
found that the user's home power supply has no ground wire, or the power ground wire is detected to be
energized, and there are no eective on-site rectication measures, it is prohibited to install the product.
• Before drilling holes in walls and oors, if the holes conceal wires or conduits and the locations of wires,
water pipes, gas pipes, etc. cannot be clearly identied, you must conrm with the user. You can also use
an induction test pen to detect whether there is a power line passing through the drilling location to avoid
personal injury accidents caused by the drill bit damaging the power line.
• During installation and maintenance operations, disconnect the main power supply.
• To prevent safety issues such as electrical overload and leakage, it is recommended to install a leakage
protection switch when connecting the power cord to the electrical appliance. This will help to promptly cut
o the power supply in case of any issues with the unit, protecting you and your family.
• When installing, repairing, or replacing TP valves, inlet and outlet pipes, avoid collision between tools and
threads at the connections as this can damage the threads or cause the sealed connection to fail and lead
to water leakage.
background
mrcool.com 4
4
SAFETY
1
WATER TEMPERATURE WARNINGS
• Safety and energy conservation are factors to be considered when selecting the water temperature setting
of the water heater's thermostat.
• Water temperatures above 125°F (52°C) can cause severe burns or death from scalding.
• Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on
the water heater near the thermostat access panel.
• Households with small children, disabled individuals, or elderly persons may require a 120°F (49°C) or
lower thermostat setting to prevent contact with hot water.
• The temperature of the water in the heater is regulated by the adjustable service mounted thermostat(s)
located behind the jacket access panel(s). Dual element heaters have two thermostats. To comply with
safety regulations, the thermostats were set at 120°F (49°C) before the unit was shipped from the factory.
• Mixing valves are recommended for reducing point of use water temperature by mixing hot and cold water
in branch water lines. It is recommended that a mixing valve complying with the Standard for Temperature
Actuated Mixing Valves for Hot Water Distribution Systems, ASSE 1017 be installed.
DANGER
• Water temperature over 125°F (52°C) can cause
severe burns instantly or death from scalds.
• Children, disabled individuals, and the elderly are at
highest risk of being scalded.
• See the instruction manual before setting the water
heater's temperature.
• Feel water before bathing or showering.
• Temperature limiting valves are available.
Temperature Time to Produce a Serious Burn
120°F / 49°C More than 5 minutes
125°F / 52°C 1.5-2 minutes
130°F / 54°C
About 30 seconds
135°F / 57°C
About 10 seconds
140°F / 60°C
Less than 5 seconds
145°F / 63°C
Less than 3 seconds
150°F / 66°C
About 1.5 seconds
155°F / 68°C
About 1 second
The chart above may be used as a guide in
determining the proper water temperature for your
home.
FOR YOUR RECORDS:
Write the model and serial numbers here. You can
nd them on a label on the unit. Staple the sales
slip or canceled check here. Proof of the original
purchase date is needed to obtain service under the
warranty.
MODEL #: _______________________________
SERIAL #: ________________________________
WARNINGS, CONTD.
• To ensure the safety performance of your home water pipes, we recommend that you choose high-quality
pipes (PPR, CPVC, and PEX) that are resistant to high temperature, pressure, and corrosion when installing
them.
• To ensure the long-term ecient operation of the water heater, it is recommended having the inner
tank cleaned once a year by a qualied installer or plumber to remove the sediment on the electrical
components inside the tank.
background
mrcool.com5
2.1 Location Selection
Regulations
This water heater must be installed in accordance with these instructions, local codes, utility codes, utility
company requirements or, in the absence of local codes, the latest edition of the National Electrical Code.
Location
Install the water heater in a clean, dry area as near as practically possible to the area with the greatest demand
for heated water. Long, uninsulated hot water lines can waste energy and water.
Place the water heater in such a manner that the thermostat and element access panels can be removed to
permit inspection and servicing such as removal of elements or checking controls.
The water heater and water lines should be protected from freezing temperatures. Do not install the water
heater in outdoor, unprotected areas.
Make certain the oor underneath the water heater is strong enough to suciently support the weight of the
water heater once it is lled with water.
It is prohibited to install water heaters in bathrooms, outdoors, or in other humid or open environments to
prevent electrical malfunctions.
INSTALLATION
2
Drain pan kits are available from any water heater
distributor.
NOTE
The auxiliary drain pan must conform to local codes.
CAUTION
The water heater should not be located in an area
where leakage of the tank or connections will result in
damage to the area adjacent to it or to lower oors of
the structure. Where such areas cannot be avoided, it
is recommended that a suitable catch pan, adequately
drained, be installed under the water heater.
2.2 Shipment Inspection
Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be
certain the power supply corresponds to the water heater requirements.
2.3 Thermal Expansion
When a water heater is installed in a closed water-supply system, such as one having a backow preventer in the
cold-water supply, means should be provided to control thermal expansion. Contact the water supplier or local
plumbing inspector for information regarding the control of the situation.
Determine if a check valve exists in the inlet water line. Check with your local water utility. It may have been
installed in the cold water line as a separate back ow preventer, or it may be part of a pressure reducing valve,
water meter, or water softener. A check valve located in the cold water inlet line can cause what is referred to as
a "closed water system". A cold water inlet line with no check valve or back ow prevention device is referred to
as an "open" water system.
As water is heated, it expands in volume and creates an increase in the pressure within the water system. This
action is referred to as "thermal expansion". In an "open" water system, expanding water which exceeds the
capacity of the water heater ows back into the city main where pressure is easily dissipated.
Fig. 2.1
background
mrcool.com 6
6
2.4 Water Supply Connections
NOTE: Do not apply heat to the hot and cold water
connections. If sweat connections are used, sweat
tubing to the adapter before tting the adapter
to the water connections on the heater. Any heat
applied to the water supply ttings will permanently
damage the dip tube and/or heat traps.
INSTALLATION
2
A "closed water system", however, prevents the expanding water from owing back into the main supply line,
and the result of the "thermal expansion" can create a rapid and dangerous pressure increase in the water
heater and system piping. This rapid pressure increase can quickly reach the safety setting of the relief valve,
causing it to operate during each heating cycle. Thermal expansion, and the resulting rapid and repeated
expansion and contraction of components in the water heater and piping system can cause premature failure of
the relief valve, and possibly the heater itself. Replacing the relief valve will not correct the problem.
The suggested method of controlling thermal expansion is to install an expansion tank in the cold water line
between the water heater and the check valve (refer to the illustration below). The expansion tank is designed
with an air cushion built in that compresses as the system pressure increases, thereby relieving the over
pressure condition and eliminating the repeated operation of the relief valve. Other methods of controlling
thermal expansion are also available. Contact your installing contractor, water supplier, or plumbing inspector
for additional information regarding this subject.
Refer to the illustration below for a suggested typical installation. The installation of unions or exible copper
connectors is recommended on the hot and cold water connections so that the water heater may be easily
disconnected for servicing if necessary. The HOT and COLD water connections are clearly marked and are 3/4"
NPT on all models. Install a shut-o valve in the cold water line near the water heater.
2.5 Typical Installation
Fig. 2.2 Fig. 2.3
To electrical
distribution panel
To electrical
distribution panel
Fig. 2.4
background
mrcool.com7
INSTALLATION
2
CAUTION
To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and
pressure protective equipment as required by local codes and no less than a combination temperature
and pressure relief valve certied by a nationally recognized testing laboratory that maintains periodic
inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves
and Automatic Gas Shuto Devices for Hot Water Supply Systems, ANSI Z21.22. This valve must be
marked with a maximum set pressure not to exceed the marked maximum working pressure of the water
heater. Install the valve into an opening provided and marked for this purpose in the water heater. Orient
the piping so that any water exiting the valve is no higher than 6 inches above the oor and does not
contact any live electrical part. The discharge opening must not be blocked or reduced in size under any
circumstances.
2.6 Relief Valve
The BTU/h rating of the relief valve must not be less than the input rating on the water heater as indicated on
the rating label located on the front of the heater (1 watt = 3.412 BTU/h).
Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live
electrical parts or persons and to eliminate potential water damage.
Piping used should be of a type approved for hot water distribution. The discharge line must be no smaller than
the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the
relief valve and discharge line.
WARNING
The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water
heater as marked on the rating plate.
2.7 Filling the Water Heater
Make certain the drain valve on the water heater is completely closed. Open the shut-o valve in the cold water
supply line. Open each hot water faucet slowly to allow the air to vent from the water heater and piping.
A steady ow of water from the hot water faucet(s) indicates a full water heater.
WARNING
Do not turn on the electrical supply or operate this water heater unless it is completely full of water. The tank
must be full of water before the heater is turned on. The water heater warranty does not cover damage or
failure resulting from operation with an empty or partially empty tank.
2.8 Condensation
Condensation can form on the tank when it is rst lled with water. Condensation might also occur with a heavy
water draw and very cold inlet water. This condition is not unusual, and will disappear after the water becomes
heated. If, however, the condensation continues, examine the piping and ttings for possible leaks.
2.9 Energy Cover
Items Required (Included and only required with Low Boy):
• Water Heater Energy Cover Side (insulation)
• Water Heater Energy Cover Top (insulation)
• Tape Strips
background
mrcool.com 8
8
INSTALLATION
2
2.10 Electrical Connections
A separate branch circuit with copper conductors, over-
current protective device and suitable disconnecting
means must be provided by a qualied electrician.
All wiring must conform to local codes or the latest
edition of National Electrical Code ANSI/NFPA 70.
The water heater is completely wired to the junction box
inside the jacket at the top front of the water heater. An
opening for 1/2" or 3/4" electrical tting is provided for
eld wiring connections. The voltage requirements and
wattage load for the water heater are specied on the
rating plate on the front of the water heater.
Connect the ground wire to the green ground screw.
To provide continued protection against risk of electrical
shock, connect to a properly grounded circuit that is
protected by a recognized Class A Ground-Fault Circuit
Interrupter (GFCI).
1. Wrap the cover around the water heater as shown if gure 2.5, pay attention to the hole positions of the
cover and the corresponding installation positions of the valve bodies on the water heater.
2. Apply 4 pieces of tape strips across the water heater energy cover side as shown in gure 2.6.
3. Press down the covers top until it laps over the upper end of the cover side as shown in gure 2.7.
4. Cut the remaining tape strips short with scissors and secure the top insulation to the cover by using 4 tape
strips that are 7 in (17.78 cm) long as shown in gure 2.8.
CAUTION
Avoid contact with eyes and skin. Wear long sleeved, loose tting clothing, gloves, and eye protection
when handling berglass. Wash with soap and warm water after handling.
Fig. 2.5
Fig. 2.6 Fig. 2.7 Fig. 2.8
Fig. 2.9
29.53in (750mm)
77.32x26.57in
(1964x675mm)
32.28in (820mm)
85.04x28.54in
(2160x725mm)
background
mrcool.com9
INSTALLATION
2
The branch circuit wiring should include either:
1. Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with
ttings approved for this purpose.
2. Non-metallic sheathed cable, metallic conduit, or metallic sheathed cable not approved for use as a ground
connector shall include a separate conductor for grounding. It should be attached to the ground terminals of
the water heater and the electrical distribution box.
CAUTION
• The presence of water in the piping and water heater does not provide sucient conduction for a
ground. Non-metallic piping, dielectric unions, exible connectors, etc. can cause the water heater to
be electrically isolated.
• Do not turn on the electrical supply or operate this water heater unless it is completely full of water.
• This appliance must be connected to a grounded, metallic, permanent wiring system or an equipment-
grounding conductor must be run with the circuit conductors and connected to the equipment-
grounding terminal or lead on the unit.
Branch Circuit Sizing & Wire Size
NOTE: This guide recommends minimum branch circuit sizing
and wire size based on the National Electric Code. Refer to the
wiring diagrams in this manual for eld wiring connections.
Total Water
Heater
Wattage
Recommended Over
Current Protection
(Fuse or Circuit Breaker
Amperage Rating)
Copper Wire Size AWG
Based on N.E.C. Table
310-16 (167°F / 75°C)
208V 240V 208V 240V
3,000 20 20 12 12
4,000 25 25 10 10
4,500 30 25 10 10
5,000 30 30 10 10
5,500 35 30 8 10
Technical Performance Parameters
Phase 1 1
Volts AC 240V 208V
Upper Element Watts 4500W 3380W
Lower Element Watts 4500W 3380W
Total Watts 4500W 3380W
Recommended Circuit
Breaker
25A 20A
Protection Against Electric Shock: Class I
2.11 Energy Eciency
This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to
insulation and standby loss requirements when the energy cover is installed. The energy cover must be installed
in accordance with the instructions provided.
2.12 Hot & Cold Pipe Insulation Installation
For increased energy eciency, the water heater includes two 24" sections of pipe insulation. Please install the
insulation, according to the illustrations above, that best meets your requirements.
Fig. 2.10 Fig. 2.11
background
mrcool.com 10
POST-INSTALLATION
3
Phase 1 1
Volts AC 240V 208V
Upper Element Watts 4500W 3380W
Lower Element Watts 4500W 3380W
Total Watts 4500W 3380W
Recommended Circuit
Breaker
25A 20A
Protection Against Electric Shock: Class I
2.13 Relief Valve Insulation Installation
3.1 Installation Checklist
A. Water Heater Locations
□ Close to the area of heated water demand.
□ Unit is indoors and protected from freezing
temperatures.
□ Area is free of ammable vapors.
□ Provisions are made to protect the area from
water damage.
B. Water Supply
□ Water heater is completely lled with water.
□ Air is purged from the water heater and
piping.
□ Water connections are tight and free of leaks.
C. Relief Valve
□ Temperature and Pressure Relief Valve is
properly installed and the discharge line allows
for proper drainage.
□ The discharge line is protected from freezing.
D. Wiring
□ Power Supply voltage agrees with water heater
rating plate.
□ Branch circuit wire and fusing or circuit
breaker of proper size.
□ Electrical connections are tight and the unit is
properly grounded.
□ Verify and check electrical grounding. Refer to
page 12.
3.2 Operating the Water Heater
CAUTION
Hydrogen gas can be produced in a hot water
system served by this water heater that has not
been used for a long period of time (generally
two weeks or more). Hydrogen gas is extremely
ammable! To dissipate such gas and to reduce
risk of injury, it is recommended that the hot
water faucet be opened for several minutes at the
kitchen sink before using any electrical appliance
connected to the hot water system. If hydrogen is
present, there will be an unusual sound such as
air escaping through the pipe as the water begins
to ow. Do not smoke or use an open ame near
the faucet at the time it is open.
Safety Precautions
A. Turn o power to the water heater if it has been
subjected to overheating, re, ood, or physical
damage.
B. Do NOT turn on the water heater unless it is lled
with water.
C. DO NOT turn on the water heater if the cold water
supply shut-o valve is closed.
D. If there is any diculty in understanding
or following the operating or maintenance
instructions within this manual, it is
recommended that a qualied person or service
person perform the work.
Safety Controls
The water heater is equipped with a combination
thermostat and temperature limiting control
(ECO) that is located above the heating element in
contact with the tank surface. If for any reason the
water temperature becomes excessively high, the
temperature limiting control (ECO) breaks the power
circuit to the heating element. Once the control
opens, it must be reset manually.
1. Turn o the power to the water heater.
2. Remove the jacket access panel(s) and insulation.
The thermostat protective cover should not be
removed.
3. Press the red RESET button.
4. Replace the insulation and jacket access panel(s)
before turning on the power to the water heater.
CAUTION
Ensure the T&P valve opening is not obstructed by
the insulation.
For increased energy eciency, some water heaters
have been supplied with a 2-3/8" section of pipe
insulation. Please install the insulation, according
to the illustrations above, that best meets your
requirements.
Fig. 2.12
background
mrcool.com11
WARNING
If the water heater has been subjected to ood, re,
or physical damage, turn o power and water to the
water heater. Do not operate the water heater again
until it has been thoroughly checked by qualied
service personnel.
CAUTION
The cause of the high temperature condition must
be investigated by a qualied service technician
and corrective action must be taken before
placing the water heater into service again.
3.3 Water Temperature Settings
The temperature of the water in the water heater can be regulated
by setting the temperature dial of the adjustable surface mounted
thermostat(s) located behind jacket access panel(s).
Dual element heaters have two thermostats.
Safety and energy conversation are factors to be considered when
selecting the water temperature setting of the water heater's
thermostat(s). The lower the temperature setting, the greater the
savings in energy and operating costs.
To comply with safety regulations, the thermostat(s) are factory
set at 120°F (49°C) or less where local codes require. This is the
recommended starting point. The factory set temperature of this
electric water heater is 125°F (52°C).
Water temperatures above 125°F (52°C) can cause severe burns or
death from scalding.
Be sure to read and follow the warnings outlined in this manual and
on the label on the water heater. This label is located on the water
heater near the thermostat access panel.
Mixing valves are recommended for reducing the point of use water
temperature by mixing hot and cold water in branch water lines. It
is recommended that a mixing valve complying with the Standard
for Temperature Actuated Mixing Valves for Hot Water Distribution
Systems, ASSE 1017 be installed. Contact a licensed plumber or the
local plumbing authority for further information.
DANGER
• There is a hot water scald potential if
the thermostat is set too high.
• Households with small children,
disabled individuals, or elderly
persons may require a 120°F (49°C)
or lower thermostat setting to
prevent contact with hot water.
Time/Temperature Relationship in Scalds
Temperature
Time to Produce a Serious
Burn
120°F / 49°C More than 5 minutes
125°F / 52°C 1.5-2 minutes
130°F / 54°C About 30 seconds
135°F / 57°C About 10 seconds
140°F / 60°C Less than 5 seconds
145°F / 63°C Less than 3 seconds
If Adjustment is Necessary:
1. Turn o the power to the water heater.
2. Remove the jacket access panel(s) and insulation
exposing the thermostat(s). The thermostat
protective cover should not be removed.
3. Using a small screwdriver, set the thermostat(s) dial
pointer(s) to the desired temperature.
4. Replace the insulation and jacket access panel(s).
Turn on the power to the water heater.
POST-INSTALLATION
3
Fig. 3.1
background
mrcool.com 12
12
POST-INSTALLATION
3
3.4 Draining the Water Heater
In order to drain the water heater, turn o the cold
water supply. Open a hot water faucet or lift the handle
on the relief valve to admit air to the tank.
Attach a garden hose to the drain valve on the water
heater and direct the stream of water to a drain. Open
the valve.
CAUTION
Shut o power to the water heater before draining
water.
3.5 Routine Preventative Maintenance
Properly maintained, your water heater will provide
years of dependable, trouble-free service.
It is suggested that a routine, preventative
maintenance program be established and followed by
the user.
It is further recommended that a periodic inspection
of the operating controls, heating element, and wiring
should be made by service personnel qualied in
electrical appliance repair.
Most electrical appliances, even when new, make some
sound in operation. If the hissing or singing sound
level increases excessively, the electric heating element
may require cleaning. Contact a qualied installer or
plumbing contractor to inspect.
At least once a year, lift and release the lever handle
on the temperature pressure relief valve, located near
the top of the water heater, to make certain the valve
operates freely. Allow several gallons to ush through
the discharge line to an open drain.
A water heater's tank can act as a setting basin for
solids suspended in the water. It is therefore not
uncommon for hard water deposits to accumulate
in the bottom of the tank. It is suggested that a few
quarts of water be drained from the water heater's
tank every month to clean the tank of these deposits.
NOTE: If the temperature and pressure relief valve
on the hot water heater discharges periodically, this
may be due to thermal expansion in a closed water
system. Contact the water supplier or your plumbing
contractor on how to correct this. Do not plug the
relief valve outlet.
3.6 Extended Shut Down
If the water heater is to remain idle for an extended
period of time, the power and water to the appliance
should be turned o to conserve energy and prevent a
build-up of dangerous hydrogen gas.
The water heater and piping should be drained if they
might be subjected to freezing temperatures.
After a long shut-down period, the water heater's
operation and controls should be checked by qualied
service personnel. Make certain the water heater is
completely lled again before placing it in operation.
NOTE: Refer to the Hydrogen Gas caution in "3.2
Operating the Water Heater".
3.7 Anode Rod
This water heater is equipped with an anode rod
designed to prolong the life of the glass lined tank. The
anode rod is slowly consumed, thereby eliminating or
minimizing corrosion of the glass-lined tank.
Water sometimes contains a high sulfate and/or
mineral content and together with cathodic protection
processes can produce a hydrogen sulde, or rotten
egg odor in the heated water. Chlorination of the water
supply should minimize the problem.
NOTE: Do NOT remove the anode rod from the
water heater's tank, except for inspection and/
or replacement, as operation with the anode rod
removed will greatly shorten the life of the glass lined
tank and will exclude warranty coverage.
Rapid closing of faucets or solenoid valves in automatic
water-using appliances can cause a banging noise
heard in a water pipe. Strategically located risers in the
water pipe system or water hammer arresting devices
can be used to minimize the problem.
The anode rod should be removed from the water
heater's tank annually for inspection and replaced
when more than 6" of core wire is exposed at either
end of the rod.
Make sure the cold water supply is turned o before
removing the anode rod.
Fig. 3.2
background
mrcool.com13
POST-INSTALLATION
3
3.9 Troubleshooting
Review the following chart before calling for service.
Problem Causes What To Do
Rumbling Noise
Water conditions in your home caused a build-up of
scale or mineral deposits on the heating elements.
Remove and clean the heating elements.
Relief valve producing
popping noise or
draining
Pressure build-up caused by thermal expansion in a
closed system.
This is an unacceptable condition and must be
corrected. Contact the water supplier or plumbing
contractor on how to correct this. Do not plug the
relief valve outlet.
Not enough or no hot
water
Water usage may have exceeded the capacity of the
water heater.
Wait for the water heater to recover after an
abnormal demand.
A fuse is blown or a circuit breaker tripped. Replace fuse or reset circuit breaker.
Electric supply may be o.
Make sure the electric supply to the water heater and
disconnect switch, if used, are in the ON position.
The thermostat may be set too low.
See the temperature regulation section of this
manual.
Leaking or open hot water faucets. Make sure all faucets are closed.
Electric service to your home may be interrupted. Contact the local electric utility.
Improper Wiring See the installation section of this manual.
Manual reset limit (ECO).
See the temperature regulation section of this
manual.
Cold water inlet temperature may be colder during
the winter months.
This is normal. The colder inlet water takes longer to
heat.
Water is too hot The thermostat is set too high.
See the temperature regulation section of this
manual.
3.8 Grounding
WARNING
Improper grounding can result in serious injury or death from electric shock. This water heater must be
properly grounded in accordance with the National Electrical Code (NEC) and all local electrical codes. Failure
to provide proper grounding may result in electric shock, equipment failure, or re.
1. Purpose of Grounding - This water heater must
be grounded to ensure user safety and to allow
proper operation of overcurrent protection devices.
Grounding provides a low-resistance path to carry
away fault current in the event of a short circuit or
insulation failure.
2. Before Installation: Verify Grounding - Disconnect
the breaker and inspect the electrical connections
in the old water heater. If damage to the wiring
coming from the electrical panel is apparent, call an
electrician before continuing. Damage could look
like frayed wiring, insulation degradation, and failed
electrical bushings. Once electrical connections are
conrmed to be undamaged, disconnect the wiring
and removed the old water heater.
3. During Installation:
• Visual Inspection of Water Heater - Conrm the
green or bare copper grounding wire is securely
connected to the heater's ground screw within the
terminal box located on the top pan.
• Continuity Test - Connect the wiring from the panel
box to the water heater. Then, using a multimeter,
check for electrical continuity between the water
heater's metal jacket (or ground terminal), the
ground terminal screw located on the breaker panel
(e.g., service panel ground bar or grounded outlet
box). The resistance should be close to 0 ohms. A
high resistance indicates a faulty or broken ground.
If broken, contact a qualied electrician for repair.
• Ground Loop Impedance Test (if required by
local code) - For professional verication, a loop
impedance tester can be used to verify that the
ground path has suciently low impedance
allowing breakers to safely trip in fault conditions.
4. After installation: Conrm Connection - Ensure
that all wire terminations are tight and corrosion-
free. Do not paint over bonding or grounding
points. Do not energize the unit until grounding is
conrmed.
background
mrcool.com 14
14
POST-INSTALLATION
3
3.10 Replacement Parts
CAUTION
For your safety, DO NOT attempt the repair of electrical wiring, thermostats, heating elements, or other
safety devices. Refer repairs to qualied service professionals.
To order replacement parts, contact MRCOOL
®
tech support at https://mrcool.com/contact or call (270) 366-
0457. Use the following diagram to identify the needed replacement parts.
Fig. 3.3
Fig. 3.4
Fig. 3.5
background
mrcool.com15
POST-INSTALLATION
3
3.11 Service Needs
Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine
maintenance, it is suggested that you rst contact your installer, plumbing contractor, or previously agreed upon
service agency.
Should your problem not be solved to your complete satisfaction, contact MRCOOL
®
tech support at https://
mrcool.com/contact or call (270) 366-0457.
When contacting contact MRCOOL
®
tech support, it is helpful to have the following information available:
• Model and serial number of the water heater as shown on the rating plate attached to the jacket of the
heater.
• Address where the water heater is located and its physical location.
• Name and address of the installer and any service agency who performed service on the water heater.
• Date of original installation and dates any service work was performed.
• Details of the problems as you can best describe them.
3.12 Wiring Diagram
This electric water heater is wired as indicated below.
Double Element Non-Simultaneous
* Grounding conductor may be required. Refer to wiring section of this manual.
This water heater is factory equipped for two (2) wire connection to electrical
power. For use with "o-peak" meter (timer), remove the wire nut from the red
and black leads and connect to "o-peak" meter (timer).
Fig. 3.6
background
Electric Tank
Water Heater
The design and specications of this product and/or manual are subject to change without prior notice.
Consult with the sales agency or manufacturer for details.

Specifications

Mrcool MTWH04528EL Questions and Answers

Questions and Answers

Related Products