Westinghouse WTA070 WGo 70W PD Universal Travel Adapter

Product's Documents

Below are documents related to this product, you can read online or download:
WTA070 photo

WGo 70W PD Universal Travel Adapter User Manual

This is the main product document for model WTA070.

The file format is pdf, 23 pages, you can download this manual here .

background
Please read this manual carefully before using
our adapter and keep it for future reference.
User Manual
Model: WTA070
WGo 70W Universal Travel Adapter
background
01
WARNINGS
Westinghouse and all its related parties, including, but
not limited to, manufacturers, dealers, distributors,
sponsored influencers, assume no liability for any
damage, loss or injury caused by using our adapter in
violation of the following warnings:
This adapter (AC-AC) does NOT convert voltage.
The input voltage of the appliance you want to connect
MUST match the local power network voltage.
Unplug the adapter when not in use.
Do not use with appliances requiring ground wire.
Do not use the adapter if the housing is damaged.
Do not expose to liquid, moisture or humidity.
Do not use it with electronic devices that demand power
over (1000W at 100V~; 2400W at 240V~).
Do not handle with wet hands.
Keep out of reach of children.
Indoor use only.
background
02
PRODUCT OVERVIEW
Type-A
Socket x 2
USB-C x 3
Plug Toggle
USB-A x 2
Universal Socket
LED Indicator
(Steady White:
Normal
operation)
background
Specifications
Rating: 100V-240V~, 50/60Hz, 10A MAX
Input: 100V-240V~, 50/60Hz, 1.8A MAX
(For USB ports load)
C1: 5.0V 3.0A 15.0W / 9.0V 3.0A 27.0W / 12.0V 3.0A
36.0W / 15.0V 3.0A 45.0W / 20.0V 3.5A 70.0W
(70.0W MAX)
C2/C3: 5.0V 3.0A 15.0W (15.0W MAX)
A1/A2: 5.0V 2.4A 12.0W (12.0W MAX)
C1+C2/C3=45.0W+15.0W
C1+A1/A2=45.0W+12.0W
C1+(C2+C3)=45.0W+15.0W
C1+(A1+A2)=45.0W+12.0W
C1+(C2/C3+A1/A2)=45.0W+15.0W
C1+(C2+C3+A1+A2)=45.0W+15.0W
Total USB Output: 70.0W MAX
03
Packing List
Travel Adapter x 1 User Manual x 1
background
04
HOW TO USE THE ADAPTER
Use Plug:
Press the toggle (A) and push out
the desired plug to use.
Done Using:
Press the toggle (A) and slide
it all the way back.
US Plug for Canada, Colombia,
Japan, Mexico, USA, etc.
A
A
background
05
UK Plug for Ireland, Malaysia,
Singapore, the UK, UAE, etc.
EU Plug for all continental EU
countries and many other
countries in Asia, Africa and
South America.
AUS Plug for Argentina, Australia,
China, New Zealand, etc.
It shares blades with the US plug,
and you need to manually turn
them to the slant “ ” shape.
background
06
Our adapter can be used to charge or power:
a) USB-charged products such as smartphones,
smartwatches, battery sets, etc.
COMPATIBILITY
Laptop Tablet Smartphone Smartwatch
Power bank Headset Handheld
game console
Camera
b) small power devices that support dual (world-wide)
voltage, which has "100-240V, 50/60Hz" printed on it*,
such as phone or tablet chargers, most laptops, etc.
* Some brands might use "110-230V", "110/250V”,
"125/240V", or a variation of a similar range.
background
07
NOT A VOLTAGE CONVERTER
Any hair dryer
over 2000W
In the US and Canada, the standard AC outlets are
110-120V. In Europe and many other countries, they are
220-240V. Please note that our adapter does NOT
convert voltage. Using single voltage devices* at
incompatible voltage through our adapter is strictly
prohibited, as such a practice will damage your device
and lead to serious consequences like overheating,
smoke, fire, or even explosion.
* Normally you will see "120V, 60Hz" and/or "household
use only" on such devices. Some brands might use "117V",
"110-130V", or a variation of similar number or range.
Need Check: Hair tools, CPAP, electric shavers and
toothbrushes, etc.
NOT Allowed: Dyson products; Any appliance (hair dryer,
steamer, etc.) over 2000W, even if it is labeled as "dual
voltage".
Curling iron Hair straightener
Electric
toothbrush
Electric shaver
Water flosser Garment
steamer
Need Check
background
08
REPLACEMENT OF THE FUSE
Note: A blown fuse is the most common reason your
adapter AC outlet stops working. If AC fails while USB
ports still work, it is almost certain that the fuse is
blown, especially if this happens after you use a
high-power appliance like a hair dryer. The breaking
capacity of the fuse is 10A.
“FUSE" compartment: in-use fuse
“SPARE FUSE" compartment: spare fuse
Step 1: Uncover the "SPARE
FUSE" compartment and
take out the spare fuse.
Step 4: Reinstall the fuse
holder and cover to the
compartments.
Step 2: Remove the fuse
holder from the "FUSE"
compartment.
Step 3: Replace the in-use
(now blown) fuse with
the spare fuse .
1
1
2
2
background
09
APPENDIX A – COMPATIBLE
SOCKETS
Please refer to this chart if you live in the US and plan to
travel to other countries with your US 2-prong or 3-prong
device. Again, you need to make sure the input voltage of
the appliance you want to connect must be compatible
with the local power network voltage.
WTA070 adapter can plug into Type A, B, C, E, F, G, H, l, J,
K, L, N, O sockets.
It does NOT fit into the Type D socket in India and Nepal,
or the Type M socket in South Africa, Swaziland and
Lesotho - if you are traveling to these countries with our
WTA070 adapter, please make sure the place you stay
have the newer Type C or Type N sockets. Otherwise, or
simply unsure, you will need to bring specific Type D or
Type M adapters.
Type A
Type F
Type K
Type B
Type G
Type L
Type C
Type H
Type M
Type D
Type I
Type N
Type E
Type J
Type O
background
10
APPENDIX B – PLUGS ACCEPTED
APPENDIX C – COMPATIBLE
COUNTRIES & REGIONS 200+
Most countries in Europe, North America, and Australia
have well-defined plug, socket, and voltage standards.
On the other hand, many South American, Asian, and
African countries adopt mixed standards, and some of
them are incompatible, due to historical reasons.
Please refer to this chart if your device is not purchased
in the US and you want to check if it can be plugged into
our WTA070 travel adapter. WTA070 adapter can accept
Type A, B, C, D, E/F, G, H, l, J, L, N, O plugs from other
countries.
Type F
Type K
Type G
Type L
Type H
Type M
Type I
Type N
Type A Type B
Type C
Type D Type E
Type J
Type O
background
11
The voltage in some countries even diers from region to
region. This makes it very hard for travelers to determine
what kind of adapter (or voltage transformer) is needed
for their trip. We made this list, to the best of our
knowledge, to give you a general idea of what types of
plugs or sockets are used in over 200 countries and
regions. However, with so many areas in the world and
ever-changing regulations, no single list could cover all
areas and be absolutely accurate. We cannot guarantee
the information provided here is error-free or up-to-date.
You should not rely solely on the information in the list;
it is still your responsibility to do more in-depth adapter
research for your trip.
As a rule of thumb for US or Canadian travelers, if you
don’t see Type M in that country or region, our adapter
will work, provided your device uses the same voltage or
supports dual voltage. If you see Type M, more research is
needed. You can also message us for more information.
√ = Our adapter can plug into the sockets in that
country AND accept devices with that country’s plug.
(Example: US, UK, Germany, France, Italy, Australia,
China etc.)
1
Socket only = Our adapter can plug into the sockets in
that country, but NOT accept devices with that
country’s plug. (Example: Denmark, Greenland)
2
background
12
Warning: Our adapter is NOT a voltage converter or
transformer. Westinghouse and all its related parties
assume no liability for any damage, loss, or injury caused
by using your device with an incompatible voltage
through our adapter.
× = This country only uses Type D or M standard and
our adapter simply won’t work in that country or
accept devices from that country. (Example: Lesotho,
Swaziland)
5
Plug only = Our adapter is NOT able to plug into the
sockets in that country, but it able to accept devices
with that country’s plug. (Example: N/A)
3
Partially = This country has more than one socket/plug
standard, and one of them is Type D or M. You need to
check with the place you are going to visit or stay if
they have sockets other than Type D or M. (Example:
India, South Africa)
4
background
13
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Countries & Regions
Abu Dhabi 50 Hz
Hertz
230 V
Voltage
G
Plug/Socket Type
Afghanistan
C / F 220 V 50 Hz
Albania
C / F 50 Hz230 V
Algeria
C / F 230 V 50 Hz
American Samoa
Andorra
Angola
Anguilla
Antigua
Argentina
Armenia
Aruba
Australia
Austria
Azerbaijan
Azores
A / B / F / I 120 V 60 Hz
C / F 230 V 50 Hz
C / F 220 V 50 Hz
A / B 110 V 60 Hz
A / B 230 V 60 Hz
C / I 220 V 50 Hz
C / F 230 V 50 Hz
120 V 60 HzA / B / F
I 230 V 50 Hz
C / F 230 V 50 Hz
C / F 220 V 50 Hz
A / B / C / F 230 V 50 Hz
Bahamas
Bahrain
Balearic Islands
Bangladesh
Barbados
A / B 120 V 60 Hz
G 230 V 50 Hz
C / F 230 V 50 Hz
A / B / D / G 220 V 50 Hz
A / B 115 V 50 Hz
Belarus
Belgium
Belize
Benin
Bermuda
Bhutan
Bolivia
Bonaire
Bosnia
Botswana
Brazil
C / F 220 V 50 Hz
C / E 230 V 50 Hz
A / B / G 110 V/ 220 V 60 Hz
C / E 220 V 50 Hz
A / B
120 V
60 Hz
C / / GD 230 V 50 Hz
A / C 230 V 50 Hz
A / C 127 V 50 Hz
C / F 230 V 50 Hz
D / G 230 V 50 Hz
C / N 127 V/ 220 V 60 Hz
Brunei 50 Hz240 VG
Bulgaria
C / F 230 V 50 Hz
Burkina Faso
C / E 50 Hz220 V
Burundi
C / E 220 V 50 Hz
Cambodia
Cameroon
Canada
Canary Islands
A / C / G 230 V 50 Hz
C / E 220 V 50 Hz
A / B 120 V 60 Hz
C / E / F 230 V 50 Hz
Cape Verde
C / F 230 V 50 Hz
background
14
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Countries & Regions HertzVoltagePlug/Socket Type
Cayman Islands
Central African Repub
A / B 120 V 60 Hz
C / E 220 V 50 Hz
220 V 50 Hz
230 V 50 Hz
220 V 50 Hz
220 V 50 Hz
230 V 50 Hz
230 V 50 Hz
110 V 60 Hz
220 V 50 Hz
230 V 50 Hz
220 V 50 Hz
240 V 50 Hz
120 V 60 Hz
220 V 50 Hz
230 V 50 Hz
110 V/ 220 V
60 Hz
127 V 50 Hz
230 V 50 Hz
230 V 50 Hz
230 V 50 Hz
220 V 50 Hz
230 V 50 Hz
Chad
Channel Islands
Chile
China
Christmas Island
Cocos (Keeling) Islands
Colombia
Comoros
Congo-Brazzaville
Congo-Kinshasa
Cook Islands
C / E / F
C / G
C / L
A / C / I
I
I
A / B
C / E
C / E
C / E
I
Costa Rica
Cote díIvoire
Croatia
Cuba
Curacao
Cyprus
Czech Republic
Denmark
Djibouti
Dominica
A / B
C / E
C / F
A / B / C / L
A / B
G
C / E
C / E / F / K
C / E
D / G
Socket only
Dominican Republic
Dubai
East Timor
Ecuador
Egypt
El Salvador
England
Equatorial Guinea
Eritrea
Estonia
Ethiopia
Faroe Islands
Falkland Islands
Fiji
Finland
France
French Guiana
60 Hz120 VA / B / C
G 230 V 50 Hz
C / E / F / I 50 Hz220 V
A / B 120 V 60 Hz
C / F 220 V 50 Hz
A / B 120 V 60 Hz
G 230 V 50 Hz
C / E 220 V 50 Hz
C / L 230 V 50 Hz
C / F 230 V 50 Hz
C / F / G 220 V 50 Hz
230 V 50 Hz
240 V 50 Hz
240 V 50 Hz
230 V 50 Hz
230 V 50 Hz
230 V 50 Hz
C / E / F / K
G
I
C / F
C / E
C / E
220 V 50 HzC / E
French Polynesia
background
Countries & Regions Hertz
50 Hz
Voltage
220 V
Gabon
Partially
15
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
230 V
50 HzC / F
Latvia
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
230 V
230 V
220 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
110 V
120 V 60 Hz
Gambia
Gaza Strip
Georgia
Germany
/ D
Plug/Socket Type
C / E
G
C / H
C / F
G
G
G
C / F
C / F
Ghana
Gibraltar
Great Britain (GB)
Greece
Greenland
Grenada
Guadeloupe
Guam
Guatemala
Socket only
Guinea-Bissau
Guyana
Haiti
Honduras
Hong Kong
Hungary
Iceland
India
Indonesia
Iran
Iraq
Ireland
Isle of Man
Israel
Italy
Jamaica
Japan
Jordan
50 Hz
60 Hz
60 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50/60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
Kazakhstan
Kenya
Kiribati
Kosovo
Kuwait
Kyrgyzstan
Laos
Guinea
50 Hz
220 V
120 V/ 240 V
110 V
120 V
220 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
110 V
100 V
230 V
220 V
240 V
240 V
230 V
240 V
220 V
230 V
220 V
C / E / F / K
G
C / E
A / B
A / B
C / E / F
/ GD
C / / M
/ GD
C / / F / G / J
A / B /
A / B
A / B
G
C / F
C / F
D
C / F
C / F
C /
G
C / G
C / H
C / F / L
A / B
A / B
D
C / F
G
I
G
C / F
A / B / C / E / F
C / F
C / F
background
Countries & Regions HertzVoltagePlug/Socket Type
C / / GD
Lebanon
16
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
230 V
220 V
120 V/ 220 V
230 V
230 V
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
M
A / B / C / F
C / L
C / J
Lesotho
Liberia
Libya
Liechtenstein
X
Lithuania
50 Hz230 VC / F
C / F 230 V 50 Hz
G 50 Hz220 V
C / F
C / E
C / F
G
G
C / / G / LD
C / E
G
A / B
C / E
C / E / F
C / G
C / E
A / B
A / B
C / F
230 V 50 Hz
220 V 50 Hz
230 V 50 Hz
230 V 50 Hz
230 V 50 Hz
230 V 50 Hz
220 V 50 Hz
230 V 50 Hz
120 V 60 Hz
230 V 50 Hz
220 V 50 Hz
230 V 50 Hz
230 V 50 Hz
127 V 60 Hz
120 V 60 Hz
230 V 50 Hz
230 V 50 Hz
50 Hz
Partially
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
C / E / F
C / F
C / F
A / B
C / E
C / F / M
Luxembourg
Macau
Macedonia
Madagascar
Madeira
Malawi
Malaysia
Maldives
Mali
Malta
Marshall Islands
Martinique
Mauritania
Mauritius
Mayotte
Mexico
Micronesia
Moldova
Monaco
Mongolia
Montenegro
Montserrat
Morocco
Mozambique
230 V
230 V
230 V
220 V
220 V
Myanmar
Namibia
Nauru
Nepal
Netherlands
New Caledonia
New Zealand
Partially
A / C / / G / ID
D / M
I
C / D / M
C / F
C / E
I 230 V
220 V
230 V
230 V
220 V
240 V
230 V
Partially
Nicaragua
Niger
Nigeria
Niue
60 Hz120 V
220 V
230 V
230 V
A / B
C / / ED
D / G
I
50 Hz
50 Hz
50 Hz
background
Norfolk Island
North Cyprus
North Korea
Northern Ireland
Norway
Oman
Pakistan
Palau
Palestine
Panama
Papua New Guinea
Paraguay
Peru
Philippines
Pitcairn Islands
230 V
230 V
220 V
230 V
230 V
240 V
230 V
120 V
230 V
120 V
240 V
220 V
220 V
220 V
230 V
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
50 Hz
60 Hz
60 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
60 Hz
50 Hz
60 Hz
50 Hz
Socket only
Poland
Portugal
Puerto Rico
Qatar
RÈunion
Romania
Russia
Rwanda
Saba
Saint BarthÈlemy
Saint Helena
Saint Kitts and Nevis
Saint Lucia
230 V
230 V
120 V
240 V
230 V
230 V
220 V
230 V
110 V
230 V
230 V
230 V
230 V
Saint Martin
Saint Pierre and Miquelon
Saint Vincent and the Grenadines
Samoa
San Marino
Sao TomÈ and PrÌncipe
Saudi Arabia
Scotland
Senegal
Serbia
Seychelles
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
220 V
230 V
110V/230V
230 V
230 V
230 V
220 V
230 V
230 V
230 V
240 V
Sierra Leone
Singapore
50 Hz
50 Hz
230 V
230 V
D / G
G
17
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Countries & Regions HertzVoltage
I
G
C / F
G
C / F
G
DC /
A / B
C / H
A / B
I
A / C
A / B / C
A / B / C
I
C / E
C / F
A / B
G
C / E
C / F
C / F
C / E / F / G
A / B
C / E
G
D / G
G
C / E
C / E
A / B / G
I
C / F / L
C / F
G
G
C / / ED
C / F
G
Plug/Socket Type
√
√
√
√
√
√
√
background
Sint Eustatius
Sint Maarten
Slovakia
Slovenia
Solomon Islands
Somalia
Somaliland
South Africa
South Korea
South Sudan
Spain
Sri Lanka
Sudan
Suriname
Swaziland
Sweden
Switzerland
Syria
Tahiti
60 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
220V
110V/ 220V
110 V
230 V
230 V
230 V
220 V
220 V
230 V
220 V
230 V
230 V
230 V
230 V
127V/
230 V
230 V
230 V
220 V
220 V
X
Partially
Taiwan
Tajikistan
Tanzania
Thailand
Togo
Tokelau
Tonga
Trinidad & Tobago
Tunisia
Turkey
Turkmenistan
Turks and Caicos Islands
Tuvalu
Uganda
Ukraine
United Arab Emirates
United Kingdom
United States
Uruguay
Uzbekistan
Vanuatu
Vatican City
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
110 V
220 V
230 V
230 V
220 V
230 V
240 V
115 V
230 V
230 V
220 V
120 V
230 V
240 V
230 V
230 V
230 V
120 V
220 V
220 V
230 V
230 V
A / B
C / F
D / G
A / B / C / O
C / E
I
I
A / B
C / E
C / F
C / F
A / B
I
G
C / F
G
G
A / B
C / F / L
C / F
I
C / F / L
18
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Countries & Regions HertzVoltage
A / B / C / F
A / B
C / E
C / F
G / I
C / G
C / G
C / / NM
C / F
C / D
C / F
D / G
C / D
A / B / C / F
M
C / F
C / J
C / E / L
C / E
Plug/Socket Type
background
FCC Statement
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
Venezuela
Vietnam
Virgin Islands (British/USA)
Wales
Wallis and Futuna
West Bank
Western Sahara
Yemen
Zambia
Zimbabwe
60 Hz
50 Hz
60 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
120 V
220 V
110 V
230 V
220 V
230 V
220 V
230 V
230 V
230 V
A / B
A / B / C
A / B
G
C / E
C / H
C / E
A / / GD
C / / GD
D / G
Socket only
19
√
√
√
√
√
√
√
√
√
Countries & Regions HertzVoltagePlug/Socket Type
background
20
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning the
equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a circuit
dierent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician
for help.
Important: You are cautioned that changes or
modifications not expressly approved by the party
responsible for compliance could void the user's
authority to operate the equipment.
background
21
All products bearing this symbol are waste electrical and
electronic equipment (WEEE as in directive 2012/19/EU)
which should not be mixed with unsorted household
waste. Instead, you should protect human health and the
environment by handing over your waste equipment to a
designated collection point for the recycling of waste
electrical and electronic equipment, appointed by the
government or local authorities. Correct disposal and
recycling will help prevent potential negative
consequences to the environment and human health.
Please contact the installer or local authorities for more
information about the location as well as terms and
conditions of such collection points.
background
Manufacturer: BEYOND BRANDS MANAGEMENT LIMITED
Address: RM A6, UNIT 1 ON 11TH FLOOR, ASIA TRADE
CENTRE, NO.79 LEI MUK ROAD, KWAI CHUNG HK
and Westinghouse are trademarks of Westinghouse
Electric Corporation.
Used under license by BEYOND BRANDS MANAGEMENT
LIMITED.
https://westinghouse.com
Service Number: (866) 761-2929

Specifications

Indexed Terms: Power Delivery

Westinghouse WTA070 Questions and Answers

Questions and Answers

Related Products