Rangaire RCG301S 30" Gas Cooktop Stainless Steel, Sealed Burners, Cast Iron Grates, Die Cast Metal Burner Controls

Product's Documents

Below are documents related to this product, you can read online or download:
RCG301S photo

Installation Manual

This is the main product document for model RCG301S.

The file format is pdf, 28 pages, you can download this manual here .

background
1
Rangaire: Installation Manual
Product Installation & User Manual
background
background
24" Gas Cooktop RCG241S | 30" Gas Cooktop RCG301S | 34" Gas Cooktop RCG341S
INSTALLATION PREPARATION ...................................................................... 1
ELECTRICAL REQUIREMENTS ....................................................................... 6
INSTALLATION OPTIONS ..............................................................................7
DIMENSIONS AND CLEARANCE .................................................................... 8
POWER SUPPLY LOCATIONS ....................................................................... 11
INSTALLATION INSTRUCTIONS .................................................................... 12
ASSEMBLE BURNERS, CHECK IGNITION ......................................................... 16
ADJUST BURNER FLAMES .......................................................................... 18
CARE AND CLEANING ...............................................................................24
background
1
Rangaire: Installation Manual
MODEL
Congratulations on the purchase of your new cooktop. We recommend that you read this instruction
/ installation Manual in order to fully understand how to install and operate it correctly.
Read all the safety instructions carefully before use and keep this Instruction / Installation Manual
for future reference.
INSTALLATION
background
2
Rangaire: Installation Manual
If the information in this manual is not followed exactly, a fire, explosion or gas leak may result, causing
property damage, personal injury or death
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your Building
Immediately call your gas supplier from a neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier
IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS COMPLETELY AND CAREFULLY
INSTALLATION
DANGER
CAUTION
Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
background
3
Rangaire: Installation Manual
IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION
BEFORE YOU BEGIN
IMPORTANT
Save these instructions for local inspector's use.
Observe all governing codes and ordinances.
Remove all packing material and literature before connecting gas and electrical supply to
cooktop.
To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate or sustain other damage.
Note to Installer: Be sure to leave these instructions with the Consumer.
Note to Consumer: Keep these instructions for future reference.
Check the leakage according to the installation instruction. Proper installation is the responsibility of
the installer. Product failure due to improper installation is not covered under the Warranty
FOR YOUR SAFETY:
Disconnect all electrical power at the main circuit breaker or fuse box before installing. Installation of this
cooktop must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/ NFPA54-Latest Edition ANSI Z223.1/ NFPA
Be sure your cooktop is installed properly by a qualified installer or service technician.
To eliminate reaching over surface burners, cabinet storage above burner should be avoided.
Do not install the unit near an outside door or where a draft may affect its use.
PLEASE READ ALL INSTRUCTIONS COMPLETELY AND CAREFULLY
background
4
Rangaire: Installation Manual
STATEMENTS OF INSTALLATION, ELECTRICAL, GAS REQUIREMENTS
INSTALLATION
A statement that the installation must conform with local codes or, in the absence of local codes,
with the National Fuel Gas Code, ANSI Z233.1/NFPA 54.
A statement that the installation of this cooktop for manufactured (mobile) home must conform
to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such
standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA
401A or with local codes. In Canada, the installation of this cooktop must conform with the current
standards CAN/CSA-A240-latest edition, or with local codes.
If an external electrical source is utilized, a statement that the appliance, when installed, must be
electrically grounded in accordance with local codes or, in the absence of local codes, with the
National Electrical Code. ANSI/NFPA 70.
A statement that:
a. The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures more than
1/2 psi (3.5kpa).
b. The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi (3.5kPa).
A statement of the maximum gas supply pressure in accordance with the inlet pressure rating of the
gas appliance pressure regulator supplied.
A description of proper vent installation, if applicable, and the specific type of gas vent to be used,
including a statement that the vent pipe must be mechanically fastened to the flue collar and
instructions for accomplishing this attachment.
The cooktop, as shipped from the factory, is set for use with its intended gas. If you wish to use your
cooktop with the alternate gas, you must first replace the orifices and convert the pressure regulator.
This conversion must be performed by a qualified installer or gas supplier in accordance with the
manufacturer’s instructions and all codes and requirements of the authority having jurisdiction.
Failure to follow instructions could result in serious injury or property damage. The qualified agency
performing this work assumes responsibility for the conversion.
background
5
Rangaire: Installation Manual
1. When preparing cooktop opening, make sure the inside of the cabinet and the cooktop do not
interfere with each other. (See section on preparing the opening.)
2. Slide the cooktop out of the end of the box. Remove packaging materials, grate boxes, regulator and
5 literature package from the cooktop before beginning installation. Use the shipping carton as a
pad to protect customer countertops or flooring
3. Remove Installation Instructions from literature package and read them carefully before you begin.
Be sure to place all literature, Owner’s Manual, Installations, etc. in a safe place for future reference.
4. Make sure you have all the tools and materials you need before starting the installation of the
cooktop.
5. Your home must provide the adequate electrical service needed to safely and properly you're your
cooktop. (Refer to section on electrical requirements.)
6. When installing your cooktop in your home, make sure all local codes and ordinances are followed
exactly as stated.
7. Make sure the wall coverings, countertop and cabinets around the cooktop can withstand heat
(up to 200°F) generated by the cooktop.
INSTALLATION PREPARATION
INSTALLATION PREPARATION
INSTALLATION PREPARATION
Surface Burner Grates (2)
24" Model
Wok Grate
LP Kits 4 pcs for 24" model
5 pcs for 30" model
Surface Burner Grates (3)
30" and 34" model
Pipe Fittings (EU ONLY)
and Rubber Gasket
Note: Purchase new line, do not use previously used flexible gas connector.
Shut-Off Valve Flexible Connector Flare Union Adapters (2)
Cooktop Burners and
Caps (4) 24" Model:
COS-640STX-E
Gas Pressure Regulator
Cooktop Burners and
Caps (5) 30" and 34"
model
Gas Pressure Regulator
Foam Tape
INSTALLATION
background
6
Rangaire: Installation Manual
This product must be installed by a licensed plumber or gas fitter.
When using ball-type gas shut-off valves, they shall be the T-handle type.
A flexible gas connector, when used, must not exceed 3 feet.
Be sure the installation of this product in a mobile home conforms with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280. If this standard does not apply, you must follow
the standard for Manufactured Home Installations, ANSI A225.1 and Manufactured Home Installations,
Sites and Communities, ANSI/NFPA 501A or with local codes. You can get a copy of the Federal Standard
by Writing: Office of Mobile Home Standards HUD Building 451 7th Street, S.W. Washington, D.C. 24010
This appliance must be supplied with the proper voltage and frequency and connected to an individual,
properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on
the rating plate.
We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified
electrician. After installation, have the electrician show you where your main cooktop disconnect is
located.
Check with your local utilities for electrical codes which apply in your area. Failure to wire your cooktop
according to governing codes could result in a hazardous condition. If there are no codes, your cooktop
must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70—
Latest Edition. You can get a copy by writing: National Fire Protection Association Battery march Park
Quincy, MA 02269 In Canada, your cooktop must be wired and fused to meet the requirements of the
Canadian Electrical Code.
IN THE COMMONWEALTH OF MASSACHUSETTS
ELECTRICAL REQUIREMENTS
READ AND SAVE THESE INSTRUCTIONS
INSTALLATION
background
7
Rangaire: Installation Manual
Refer to “Installation Preparation” for information on appropriate placement and necessary
clearances when planning installation.
Avoid placing cabinetry directly above cooktop when possible.
If cabinetry is used above cooking surface:
1. Use cabinets no more than 13” deep.
2. Maintain 30” minimum clearance between cooktop and unprotected cabinets or exhaust hood
directly above the 24inch model; maintain 34" for the 30" and 34" model cooktop.
3. If clearance is less than 30”, protect cabinet bottoms with flame-retardant millboard at least
1/4”thick, or gypsum board at least 3/16” thick, covered with 28 gauge sheet steel or .02” thick
copper.
4. Clearance between cooktop and protected cabinetry must not be less than 24”.
5. An exhaust hood that projects at least 5” beyond front of cabinets can reduce risk of burns
caused by reaching over heated surface units.
6. Working areas adjacent to the cooktop should have 18” minimum clearance between countertop
and cabinet bottom.
A 30” or wider exhaust hood with 350 CFM or greater airflow rating is recommended for use over the
640STX-E cooktop; 36" or wider for the 30" and 34" model Cooktop.
Installation must conform with local codes. In the absence of local codes, the gas cooktop must
comply with the National Fuel Gas Code, ANSI Z223.1, latest edition.
Gas supply should be located near the opening for this cooktop (see Preparing the Opening and Gas
Connection sections of this manual). The supply should provide natural gas at 7” of water column
pressure (11” of water column for LP gas) and a maximum of 14” of water column for natural or LP gas.
The electric spark ignition feature for this model requires a 120V electrical power supply be located in
the immediate vicinity of this cooktop (see Electrical Connections section of this manual).
ADVANCE PLANNING
INSTALLATION OPTIONS
INSTRUCTIONS
Cooktop and Single Oven Combination Installation
These cooktops may be installed over a 30” Oven.
Consideration must be given to electrical and gas supply locations.
Installation Above Cabinet Drawers
When installing the cooktop above a base cabinet with drawers, it may be necessary to use
a shorter depth (front to back) drawer to allow clearance for the gas connection
background
8
Rangaire: Installation Manual
INSTALLATION
To ensure accuracy, it is best to make a template for the opening.
Make sure the sides of the opening are parallel and the rear and front cuts are exactly perpendicular to
the sides.
Make sure the wall coverings, countertop and cabinets around the cooktop can withstand heat (up to
200°F) generated by the cooktop.
DIMENSIONS AND CLEARANCE
background
9
Rangaire: Installation Manual
ABOUT
PRODUCT DIMENSIONS
MODEL A. WIDTH A. WIDTH C. HEIGHT D. BOX WIDTH E. BOX DEPTH
24" model
22 13/16" (58.0) 20 1/16" (51.0) 3 3/8" (8.54) 21 7/8" (55.6) 19 1/8" (48.6)
30" and 34"
model
30 5/16" (77.0) 30"
33 7/8" (86.0) 34"
20 1/16" (51.0)
4 1/4" (10.8) 28 9/16" (72.6) 19 1/8" (48.6)
CUT OUT DIMENSIONS
F. WIDTH G. DEPTH
H.HEIGHT BELOW
COOKTOP
MODEL MIN MAX MIN MAX
24" model
22" (55.8) 22 3/16" (56.3) 19 3/16" (48.8) 19 11/16" (50.0) 8" (20.3)
30" and 34"
model
28 11/16" (72.8) 28 7/8" (73.3) 19 3/16" (48.8)
19 11/16" (50.0)
8" (20.3)
DIMENSIONS AND CLEARANCE
Electrical supply:
All dimensions are stated in inches and (cm).
Dimension H includes a 5" (12.7 cm) space underneath the cooktop for connection to gas supply line.
Install a manual shut-off valve in the gas line in an easily accessible location outside the cooktop. Be sure
you know how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12” below the
countertop.
Install a manual shut-off valve in the gas line in an easily accessible location outside the cooktop. Be sure
you know how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12” below the
countertop
This cooktop features pilotless electric ignition for energy savings and reliability. It operates on a 120 volt, 60
Hz power supply. A separate circuit, protected by a 15 amp time delay fuse or circuit breaker is required.
A properly-grounded 3-prong receptacle should be located within reach of the cooktop’s four-foot power
cord.
background
10
Rangaire: Installation Manual
ABOUT
IMPORTANT
(Please read carefully)
FOR PERSON SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a three-prong (grounding) plug which mates with
a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard
from this appliance.
The customer should have the wall receptacle and circuit checked by a qualified electrician to make
sure the receptacle is properly grounded and has correct polarity.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and
obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
Do Not, Under Any Circumstances, Cut or Remove The Third (Ground) Prong From The Power Cord.
Do not use an extension cord.
background
11
Rangaire: Installation Manual
Gas supply: These cooktops are shipped from the factory set for either natural gas or LP gas. Ensure you
have the correct cooktop for the type of gas being used.
The pressure regulator must be connected in series with the manifold of the cooktop and must
remain in series with the supply line regardless of type of gas being used.
The natural gas model is designed to operate at 5” water column pressure. A regulator is required
at the natural gas source to provide a minimum of 6” water column to the cooktop regulator
The liquid propane model is designed to operate at 10” water column pressure. A regulator is
required at the LP source to provide a minimum of 11” water column to the cooktop regulator. For
ease of installation, and if local codes permit, the gas supply line into the cooktop should be 1/2” or
3/4” ID flexible metal appliance connector, three to five feet long.
POWER SUPPLY LOCATIONS
NOTE
Purchase new flexible line. DO NOT USE OLD, PREVIOUSLY USED FLEXIBLE CONNECTOR.
ABOUT
background
12
Rangaire: Installation Manual
A. Unpack the cooktop without installing the
cooktop burners and surface grates, and
gently lay it upside down on a towel or
tablecloth covered countertop.
B. Locate electrical outlet and gas shut-off
valve beneath cabinet.
C. Apply the foam gasket tape around the
bottom edge of the cooktop. Gently insert
the cooktop right side up centered into the
cutout opening. Make sure the front edge
of the countertop is parallel to the cooktop.
Check clearances at the front, back, and
sides.
D. Secure the cooktop from underneath
with the mounting brackets and screws
supplied
E. Install the cooktop burners and caps, then
gently place the surface grates on the
cooktop.
INSTALLING THE COOKTOP
INSTALLATION INSTRUCTIONS
INSTALLATION
1
background
13
Rangaire: Installation Manual
No Obstructions Below Cooktop
A. Manifold Entrance
B. Pressure Regulator
C. Flare Union Adapter
D. Flexible Connector
E. Flare Union Adapter
F. Manual Gas Shutoff Valve
INSTALLATION
A. Screw the regulator onto the burner box bottom pipe connection. Make sure the top of the
regulator is facing toward the cabinet front and the arrow on the back of the regulator points to
the cooktop.
B. Complete the connection between the regulator and the shut-off valve.
C. Before testing for leaks, make sure all burner knobs are in the OFF position.After connecting the
cooktop to gas, check system for leaks with a manometer. If a manometer is not available, turn
the gas supply on to the cooktop and use a liquid leak detector at all joints and connections to
check for leaks.Tighten all connections if necessary to prevent gas leakage in the cooktop or
supply line.
INSTALL PRESSURE REGULATOR
INSTALLATION INSTRUCTIONS
2
All Connection must be wrench-tightened
background
14
Rangaire: Installation Manual
INSTALLATION
The gas inlet is located on the bottom of the burner box at the rear and center. Make gas connection
through rear wall, or on cabinet floor at rear, as illustrated.
1. Install the house gas supply at least 1” from the back wall.
2. Locate the electrical outlet 12” below the countertop.
Never reuse old exible connectors. The use of old exible connectors can cause gas leak and
personal injury. Always use new exible connectors when installing a gas appliance.
To reduce the possibility of gas leaks, apply Teon tape or a thread compound approved for use with
LP or Natural gas to all threaded connections.
Do not use a ame to check for leaks.
Disconnect the cooktop and its individual shut-off valve from the gas supply piping system during
any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).
Isolate the cooktop from the gas supply piping system by closing its individual shut-off valve during
any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psig (3.5 kPa)
background
15
Rangaire: Installation Manual
INSTALLATION
A. Check to be sure the receptacle is properly grounded.
B. Plug in the power cord.
CONNECT ELECTRICAL
INSTALLATION INSTRUCTIONS
ASSEMBLE BURNERS, CHECK IGNITION
IMPORTANT:
If the igniter electrodes continue to spark after all the burners are lit, check that each burner
component is assembled and properly seated.
3
The electrode of the electronic ignition system is positioned above the surface of the burner base. Do
not remove a burner cap or touch the electrode of a burner while another is turned on. Damage or
electrical shock may occur.
A. The electrode of the electronic ignition system is positioned above the surface of the burner base.
Do not remove a burner cap or touch the electrode of a burner while another is turned on. Damage
or electrical shock may occur.
B. Place burner heads over the burner base. Make sure the hole in the burner head is properly aligned
with the electrode in the burner base.
C. Place the burner caps on the burner heads. Make sure that the burner caps are properly seated on
the burner heads. Burner cap properly seated Burner cap not properly seated.
Auxiliary Burner Semi-Rapid
Burner
Rapid Burner Triple Ring
Burner
background
16
Rangaire: Installation Manual
INSTALLATION
If you attempt to measure the flame,
please use caution. Burns could result.
Burners should be checked frequently.
ASSEMBLE BURNERS, CHECK IGNITION
NOTES:
If the burner does not light within five seconds, turn the knob off and wait one minute before trying again.
D. Check igniters.
Operation of the electric igniters should be tested after the cooktop and supply line have been
carefully checked for leaks and the cooktop has been connected to the electrical power.
Push and turn a burner valve to the LITE position. All spark igniters will make a series of sparks
(ticking sounds), but only the burner turned to LITE will light.
The burner should light when gas is available to the burner.
Once the burner lights, it should be turned to another position.
· Test each valve separately until all burners have been checked.
E. Burner ignition. Cooktop Spark Ignition—When you turn the cooktop knob to LITE, the spark igniter
makes a series of electric sparks (ticking sounds) which light the burner. During a power failure, the
burners will not light automatically. In an emergency, a cooktop burner may be lit with a match by
following the steps below.
Light a match and hold the flame near the burner you want to light. Wooden
matches work best.
Push in and turn the control knob slowly. Be sure you are turning the correct knob for the burner
you are lighting.
F. Turn on each burner. On LP models, flames should be blue in color but may have yellow tips.
Natural gas models should have soft, blue flames. The burner flames should not flutter or blow away
from the burner. The flame should be no less than 1/4” on the lowest setting and no greater than 1-1/2”
on highest setting.
background
17
Rangaire: Installation Manual
OPERATION CHECKLIST
Make sure all controls are left in the OFF position.
1. The serial plate for your cooktop is located on the bottom of the burner box. In addition to the
model and serial numbers, it tells you the ratings of the burners and the type of fuel and pressure
the cooktop was adjusted for when it left the factory.
2. When ordering parts, always include the serial number, model number and a code letter to ensure
proper replacement parts.
3. Check again to be sure all installation procedures have been completed.
OPERATION
background
18
Rangaire: Installation Manual
OPERATION
ADJUST BURNER FLAMES
A. Turn all burners on highest setting and check the flames. They should be blue in color and may have
some yellow tipping at the ends of the flame when using LP gas. Foreign particles in the gas line may
cause an orange flame at first, but this will soon disappear.
B. Turn the cooktop burner knob to “LO” while observing the flame. Adjust the setting of the upper
row of flames using the valve bypass screw as follows: Adjustments must be made with two other
burners in operation on a medium setting. This prevents the upper row of flames from being set too
low, resulting in the flame being extinguished when other burners are turned on
C. To adjust the flame, remove the knobs. Insert a screwdriver through the access hole in valve shaft
as shown
If the flames were too small or fluttered, open the valve more than the original setting.
If the flames blew away from the burner, close the valve more than the original setting.
D. Make the adjustment by slowly turning the screw
until flame appearance is correct Testing Flame
Stability: Test 1— Turn the knob from “HI” to “LO”
quickly. If the upper row of flames goes out at this
setting, increase the flame size and test again.
E. Test 2— With the burner on “LO”, open and close
the cabinet door under the cooktop. If the flame
is extinguished by the air currents created by the
door movement, increase the flame height and test
again
F. Flame Recheck: After the adjustment is made,
turn all burners off. Ignite each burner individually.
Observe the flame at the “HI” position. Rotate the
knob to the lowest setting and be sure that the
flame size decreases as the knob is rotated counterclockwise
Once the conversion is complete and checked ok, fill out the conversion sticker and include your
name, organization and date conversion was made. Apply the sticker near the cooktop gas inlet
opening to alert others in the future that this appliance has been converted. If converting back to the
original gas, please remove the sticker so others know the appliance is set to use its original gas.
background
19
Rangaire: Installation Manual
CONVERT COOKTOP TO LP GAS
1
When the cooktop is converted for liquid petroleum (LP) gas, the LP gas supply is required to provide a
minimum of 10" to a maximum of 14" water column to the cooktop regulator.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's
instructions and all applicable codes and requirements of the authority having jurisdiction. If the information
in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not proper and complete until the operation of the
converted appliance is checked as specified in the manufacturer's instructions supplied with the kit.
IMPORTANT: Disconnect all electrical power at the main circuit breaker or fuse box. Shut off the gas
supply to the range by closing the manual shut-off valve.
1. Unscrew the regulator cap with the wrench.
Tools Needed for Conversion:
• Wrench • 7 mm Nut Driver • Safety Glasses • Small Flat-head Screwdriver
ADJUST THE REGULATOR
STEP
HOW TO USE
background
20
Rangaire: Installation Manual
HOW TO USE
2. Remove the retainer pin that is currently positioned for use with Natural Gas.
3. Turn the retainer pin upside down and replace it into the regulator cap. It is now positioned for
use with LP gas.
4. Screw and tighten the regulator cap back into the regulator with the wrench.
Regulator Cap
background
21
Rangaire: Installation Manual
2
IMPORTANT: Carefully read and observe each orifice label for correct location. See the Burner Chart in this
section.
24" Model
CHANGE BURNER ORIFICES
STEP
30" and 34" model
HOW TO USE
background
22
Rangaire: Installation Manual
Burner and Orifice Characteristic Table (ADA)
1. Remove the burner grates, burner caps and burner heads.
2. Using a 7 mm nut driver, remove the burner orifices.
Triple Ring Burner
Auxiliary Burner
Semi-Rapid
Burner
Rapid Burner
Orifice Size
(091 - Denotes
0.91mm)
Burner Gas Type
Orice
Diam. (mm)
Pressure
[i.w.c.]
Rate
[BTU/h]
1
Triple Ring
NG 2.1 4" 18000 BTU
LP (Propane) 1.26 10" 18000 BTU
2
Rapid
NG 1.45 4" 8500 BTU
LP (Propane) 0.91 10" 8500 BTU
3 Semi-Rapid
NG 1.29 4" 6800 BTU
LP (Propane) 0.8 10" 6800 BTU
4 Auxiliary
NG 1.1 4" 5000 BTU
LP (Propane) 0.7 10" 5000 BTU
NOTES:
First remove all orifices and then start replacing them. This will help avoid the possibility that some may
not be replaced.
HOW TO USE
background
23
Rangaire: Installation Manual
3. Install the proper orifices in the exact locations as noted in the previous graphic
4. Replace the burner bases, heads, caps and top grates. Make sure burner caps are properly seated on
the burner head.
Properly Seated
Not Properly Seated
HOW TO USE
background
24
Rangaire: Installation Manual
CARE AND MAINTENANCE
CLEANING COOKTOP
Removing Burner Grates:
1. The burner grates are located in the recessed area of the cooktop.
2. They can be removed for cleaning by carefully lifting them from the cooktop.
3. Clean by washing in warm soapy water. Make sure to dry thoroughly.
4. Do not drop the burner grates into place. To avoid scratches and damages carefully place the
burner grates back to its place.
Check again to be sure all installation procedures have been completed.
Removing the Burner:
1. The burner caps and heads are removable for cleaning.
2. Blockage of the flame port should be cleaned using a match stick or brush.
3. . If the caps, heads and cups are heavily soiled, use a non-abrasive cleaning compound to
help remove build-up.
Refitting the Burner Heads and Caps:
1. The burner cap must be placed
correctly into the burner head or
damage may occur during
operation.
2. To ensure correct placement, make
sure the Ignitor and Flame detector
(for older models) are positioned into
the 2 slots of the burner head.
(Refer to Figure 14.)
3. The burner cap is simply positioned
over the top of the burner head.
(Refer to Figure 14.)
HOW TO USE
background
25
Rangaire: Installation Manual
IMPORTANT
To avoid possible burns use care when cleaning the cooktop. DO NOT attempt to clean the cooktop
whenever the cooktop or burner heads are still hot. To avoid possible burns DO NOT attempt any of the
following cleaning instructions before turning OFF ALL the surface burners and
allowing them to cool.
Control Knobs - For general cleaning, use hot, soapy water and a cloth. For more difficult soils and built-
up grease, apply a liquid detergent directly onto the soil. Rinse with a damp cloth and dry.
DO NOT use steel wool or acidic cleaners on the knobs; as they can scratch
Burner Grates - Clean burner grates in the dishwasher and dry upon removal.
Burner Caps - Should you ever need to remove the burner caps for cleaning lift the burner cap off the
burner head. Clean heavy soils with an absorbent cloth. Rinse with a clean, damp cloth and immediately
thoroughly dry including the bottom and inside of the cap. Do not use harsh abrasive cleaners. They
can scratch the cap. Do not clean burner caps in dishwasher.
Burner Heads - The holes in the burners of your cooktop MUST be always kept clean for proper ignition
and a complete, even flame. Remove any food from between the burner slots using a small nonabrasive
brush like a toothbrush and afterwards wipe using a damp cloth. To remove deposits from the burner
cavities, remove the cap and separate the two parts. Clean the burner holes routinely with a small
gauge wire or needle and especially after bad spillovers which could clog these holes. After cleaning,
put the two parts back together and return them correctly to their position, making sure they are
seated and level. DO NOT put burner units in the dishwasher
Stainless Steel - Clean stainless steel with hot, soapy water and a dishcloth. Rinse with clean water
and a cloth. Do not use cleaners with high concentrations of chlorides or chlorines. Do not use harsh
scrubbing cleaners. Only use kitchen cleaners that are especially made for cleaning stainless steel.
CARE AND CLEANING
HOW TO USE

Specifications

Indexed Terms: Gas Cooktop, Sealed Burner

Rangaire RCG301S Questions and Answers

Questions and Answers

Related Products