1000A AC/DC CLAMP METER
Visit our website at: https://www.harborfreight.com
email our technical support at: [email protected]
59456
Owner’s Manual & Safety Instructions
Save This Manual Keep this manual for the safety warnings and precautions, assembly,
operating, inspection, maintenance and cleaning procedures. Write the product’s date code in the back
of the manual near the assembly diagram (or month and year of purchase if product has no number).
Keep this manual and the receipt in a safe and dry place for future reference. 25h
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-800-444-3353 as soon as possible.
Copyright
©
2025 by Harbor Freight Tools
®
. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

Page 2 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
table of contents
Safety .................................... 2
Specifications ........................ 5
Setup ..................................... 6
Operation ............................... 8
Maintenance ......................... 15
Warranty ............................... 16
tM
WarninG SyMBOLS anD DeFinitiOnS
This is the safety alert symbol. It is used to alert you to potential
personal injury hazards. Obey all safety messages that
follow this symbol to avoid possible injury or death.
Indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
Addresses practices not related to personal injury.

Page 3For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
iMpOrtant SaFety inFOrMatiOn
Safety Warnings and precautions
read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
1. Electrical shock can cause death or injury! NEVER
TOUCH exposed conductors of electricity.
2. test cable voltages with care. One use one
hand when securing the clamp around cable.
3. Inspect the Meter before use. In addition to
a general inspection, look specifically for:
a. Pay special attention to the insulation
protecting the connectors.
b. Check the leads for exposed metal,
damaged insulation, and continuity.
c. Replace damaged test lead
immediately, before use.
4. Do not use the Meter if:
a. Either of the test leads are
damaged in any way.
b. Test leads are dirty or have residue on them.
c. The battery is low.
d. Near any explosive gasses or fumes.
e. Any abnormal operation is detected.
(If in doubt about the condition of the
Meter, have it serviced before use.)
f. The battery cover is open.
5. Power this Meter using only the battery(ies)
referenced in the Specifications Chart.
6. Use caution when working near voltages above
30 VAC rms, 42 VAC peak, or 60 VDC. Voltages
this high present a risk of electric shock.
7. Disconnect the circuit’s power before connecting
the Meter in series, when measuring current.
8. Connect the common (COM) test
lead first and disconnect it last.
9. Hold the probes with fingers behind guards.
10. Avoid electrical shock. Use extreme caution
when working near uninsulated conductors or
bus bars. Prevent body contact with grounded
surfaces such as pipes, radiators, ranges, and
cabinet enclosures when testing voltages.
11. Observe work area conditions. Do not test
voltages in damp or wet locations. Don’t expose
to rain. Keep work area clean and well lit.
12. Keep children away. Children must
never be allowed in the work area.
13. Stay alert. Watch what you are doing,
use common sense. Do not operate
any Meter when you are tired.
14. Do not operate Meter if under the influence
of alcohol or drugs. Read warning labels on
prescriptions to determine if your judgment
or reflexes are impaired while taking drugs. If
there is any doubt, do not operate the Meter.
15. People with pacemakers should consult their
physician(s) before use. Electromagnetic fields in
close proximity to heart pacemaker could cause
pacemaker interference or pacemaker failure.
16. Do not test voltage on circuits higher
than 1000 VDC or 1000 VAC.
17. Do not test current on circuits higher than 1000 A.
18. Dress properly. Protective, electrically
nonconductive clothes and nonskid footwear
are recommended when working.
19. Wear ANSI-approved safety goggles during use.
20. Only use accessories intended
for use with this Meter.
21. Avoid damaging Meter. Use only
as specified in this manual.
22. Prior to testing resistance, diodes, or
continuity; disconnect all power to the circuit
and discharge all high-voltage capacitors.
23. Performance of this Meter may vary
depending on battery condition.
24. Use the proper settings, terminals, techniques,
and range for the tests performed. Start
with the range stated in the instructions.
25. Do not apply voltage to the Test Leads
when the Meter is in the Ohms testing
setting. Damage can occur to the Meter.
26. Do not switch between testing modes
with the Meter connected to a circuit.

Page 4 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
27. Do not use the Meter at a setting
marked as blank on the scale.
28. Have Meter calibrated by a qualified technician
every year to maintain accurate results.
29. Do not disassemble meter; take it to a
qualified technician when service or repair
is required. Incorrect reassembly may
result in a risk of electric shock or fire.
30. The warnings, cautions, and instructions
discussed in this instruction manual cannot
cover all possible conditions and situations
that may occur. It must be understood by the
operator that common sense and caution are
factors which cannot be built into this product,
but must be supplied by the operator.
SaVe tHeSe inStructiOnS.

Page 5For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
Specifications
DC Voltage Ranges: 600mV / 6V / 60V / 600V / 1000V
DC Voltage Accuracy (@0-599.9mV) ± 0.5% + 5D, (@600mV-1000V) ± 1.5% + 2D
DC Current Ranges: 600A / 1000A
DC Current Accuracy (@600A) ± 2.5% + 5D, (@1000A) ± 2.8% + 5D
AC Voltage Ranges: 6V / 60V / 600V / 1000V
Frequency Range: 50-400Hz
AC Voltage Accuracy (@1000V) ± 1.5% + 5D
AC Current Ranges: 600A / 1000A
Frequency Range:
(@0-600A) 50-400Hz, (@600A-1000A) 50-60Hz
AC Current Accuracy (@0-600A) ± 2.5% + 8D, (@0-1000A) ± 2.8% + 8D
Inrush Current Ranges: 600A / 1000A
Frequency Range: 50-400Hz
Inrush Integration Time 100mS
Resistance Ranges: 600Ω / 6kΩ / 60kΩ / 600kΩ / 6MΩ / 60MΩ
Resistance Accuracy (@0-599.9Ω) ± 1.0% + 4D, (@600Ω-599.9kΩ) ± 1.5% + 2D
(@600kΩ-599.9MΩ) ± 2.5% + 3D,
(@6MΩ-59.99MΩ) ± 3.5% + 5D
Continuity Meter beeps at < 50Ω
Diode Forward DC Current: ~ 0.3mA
Reverse DC Voltage: ~ 3.2V
Capacitance Ranges: 60nF / 600nF / 6uF / 60uF / 600uF / 6mF / 60mF / 100mF
Capacitance Accuracy (@0-59.99nF) ± 4.0% + 20D, (@60-599.9uF) ± 3.0% + 5D,
(@600uF-5.999mF) ± 5.0% + 5D, (@6mF-59.99mF) ± 5.0% + 8D,
(@60mF-99.99mF) ± 5.0% + 15D,
Frequency Current Mode Range: 100Hz / 1000Hz
Voltage Mode Range: 100Hz / 1000Hz / 100kHz
Frequency Accuracy Current Mode: ± 1.5% + 5D
Voltage Mode: ± 1.5% + 5D
Hz/Duty Mode: ± 0.3% + 5D
Duty Cycle 10.0%-90.0%
Duty Cycle Accuracy ± 1.2% + 2D
Sampling Rate ~2 samples per second
Operating Temperature Range: 41°F - 104°F (5°C - 40°C)
Operating Humidity Max 80% RH Non-Condensing
Storage Temperature Range: 14°F - 122°F (-10°C - 50°C)
Storage Humidity <80% RH Non-Condensing
Display Liquid Crystal Display (LCD)
Battery (3) AAA (Included)

Page 6 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
Setup - Before use:
read the entire iMpOrtant SaFety inFOrMatiOn section at the beginning of this
manual including all text under subheadings therein before set up or use of this product.
Functions
current
clamp
rotary
Switch
Max/Min/VFD
Button
Mode/inrush
Button
Display
input Jack
cOM Jack
range
Button
clamp
trigger
Worklight
DC
700
TM
ncV indicator
relative/
Backlight
Button
Data Hold/
Worklight
Button

Page 7For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
Display
Symbol Description
LoZ
Low impedance input mode
DDcc
Direct current
Minus sign
aacc
Alternating current
Battery low
Auto power-off
autO
Auto range mode
Diode test mode
Continuity test mode (audible)
MaX
The maximum value is being measured
Min
The minimum value is being measured
reL
Relative measurement mode
Indicates that display data is being held
VFD
Variable frequency drive mode
Inrush current mode
Ω, kΩ, MΩ
Ohms, Kilohms, Megaohms (Resistance)
nF, μF, mF
Nanofarads, Microfarads, Millifarads (Capacitance)
mV, V
Millivolts, Volts (Voltage)
a
Amperes (Current)
Hz, kHz
Hertz, Kilohertz (Frequency)
%
Percent (Duty cycle)
°c, °F
Temperature (Celsius, Fahrenheit)
Measurement reading

Page 8 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
Operating instructions
read the entire iMpOrtant SaFety inFOrMatiOn section at the beginning of this manual
including all text under subheadings therein before set up or use of this product. electrical
shock can cause death or injury! neVer tOucH exposed conductors of electricity.
General Operating instructions
reL/Backlight
1. Press the reL/Backlight button once
to enter relative measurement mode
and store a reference value.
2. Take additional measurements to
display difference between measured
value and reference value.
note: Relative measurement mode
will turn off Auto Range mode.
3. Press reL/Backlight button for two or
more seconds to enter backlight mode.
4. Press reL/Backlight button for two or
more seconds to exit backlight mode.
note: Frequent use of the backlight will shorten the life
of the batteries. Only use the backlight when necessary.
Worklight
1. Press the Data Hold/Worklight button for two
or more seconds to turn on the worklight.
2. Press the Data Hold/Worklight button
again to turn the worklight off.
Data Hold
The data hold function keeps the current reading on the Display. To activate data hold:
1. Press the Data Hold/Worklight button
and the reading will be held on the
Display. The symbol appears.
2. Press Data Hold/Worklight
again to release the hold.
tM

Page 9For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
Manual range
The Meter’s default range is autO. To select manual range, press ranGe. The Display will no longer read autO.
Each press of the button increases the range. Hold the ranGe button for two seconds to return to auto range.
note: Manual range cannot be used while measuring frequency.
auto power-Off
If the Meter is not used for approximately 15 minutes, it will automatically turn itself off to conserve
battery power. To turn the Meter back on after auto-off, press the MODe/inruSH button. To
disable Auto Power-Off, hold the MODe/inruSH button while powering the Meter on.
Maximum / Minimum Value / Variable Frequency Measurements
To enter MAX / MIN mode:
1. Press the MAX / MIN / VFD button one time.
2. Press MAX / MIN / VFD again to select
between measuring the minimum or
maximum value at any range.
3. Press and hold the MAX / MIN / VFD
button for two seconds to exit.
note: MAX / MIN does not work with capacitance.
to enter VFD mode:
note: Exit MAX / MIN mode to enter VFD mode.
1. Turn the Rotary Switch to the V Hz% position.
2. Press and hold the MAX / MIN / VFD button for
two or more seconds to enter VFD mode.
3. Press and hold the MAX / MIN / VFD
button for two seconds to exit.
note: The Meter should be set to selected
range prior to entering MAX / MIN mode.
note: Frequency and duty cycle modes
cannot be used while in MAX / MIN mode.
tM

Page 10 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
Measurement Operation
note: Remove plugs from ends of Test Leads
(included) before connecting to Meter.
note: Test Lead probes have removable covers for
overvoltage protection. With covers in place, Test
Leads are rated for use with CAT IV circuits. Exposed
probes are rated for use with CAT II circuits.
current Measurement
WarninG! tO preVent SeriOuS inJury:
To avoid electric shock, use only one hand
to hold Meter when measuring current.
WarninG! tO preVent SeriOuS
inJury: Remove test leads before taking
measurements with the Current Clamp.
note: Amperage is always tested in
series with circuit under test.
note: To measure 2- and 3-wire power cords, use an
AC Line Splitter (not included) and follow its instructions.
note: When using manual range mode, always start
with the highest range if the amperage is unknown.
note: Center conductor between
guides in Clamp jaws, as shown.
DC
700
TM
ac/Dc current
Measure AC and DC conductors
carrying up to 1000 amperes.
1. Turn the Rotary Switch to the
600 or 1000 position, depending on
the amperage of the conductor under test.
2. Always start with the highest range
if the amperage is unknown.
3. Press MODe/inruSH until ac or Dc is displayed.
4. Press reL/Backlight button to zero
display when in Dc mode.
5. Using one hand, press Clamp Trigger
to open Current Clamp. Position Clamp
jaws around conductor to be tested.
note: When measuring DC current, ensure that current
flows in the direction indicated by the Positive (+)
and Negative (-) Symbols on the Current Clamp.
6. Read measurement. Switch to lower ranges, as
necessary, to get the most accurate reading.
7. When testing is complete, turn
Rotary Switch to OFF, and store Meter.
note: If the Display shows OL while in manual
range mode, the measurement has exceeded the
selected range. A higher range should be selected.
inrush current
Measure inrush current of AC conductors
carrying up to 1000A.
1. Turn the Rotary Switch to the
600 or 1000 position, depending on
the amperage of the conductor under test.
2. Press MODe/inruSH for two or more seconds to
switch to inruSH current mode. displays
while waiting for the inrush current to be detected.
3. Using one hand, press Clamp Trigger
to open Current Clamp and insert
conductor inside the jaws.
4. Read measured inrush current on the
Display. The current is only measured once
and the reading is held on the Display.
5. When testing is complete, turn
Rotary Switch to OFF, and store Meter.
note: If the Display shows OL while in manual
range mode, the measurement has exceeded the
selected range. A higher range should be selected.

Page 11For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
ac/Dc Voltage Measurement
Measure AC conductors carrying
up to 1000VAC, 50-400Hz.
Measure DC conductors carrying up to 1000VDC.
WarninG! tO preVent SeriOuS inJury:
Use caution when working near voltages above
30VAC rms, 42VAC peak, or 60VDC. Voltages
this high present a risk of electric shock.
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the V or
V
position, depending on the voltage
of the conductor under test.
3. Press MODe/inruSH until ac or Dc is displayed.
4. Carefully touch exposed conductors
with tips of probes.
5. Read measured voltage on the Display.
6. When testing is complete, turn Rotary Switch to
OFF, remove Test Leads and store with Meter.
note: If voltage is too high, Meter will sound.
Low impedance Voltage Measurement
Measure AC conductors carrying
up to 1000VAC, 50-400Hz.
WarninG! tO preVent SeriOuS inJury:
Use caution when working near voltages
above 30VAC rms, 42VAC peak. Voltages
this high present a risk of electric shock.
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the LoZ V Hz %
position; ac and LoZ are displayed.
3. Carefully touch exposed conductors
with tips of probes.
4. Read measured voltage on the Display.
5. When testing is complete, turn Rotary Switch to
OFF, remove Test Leads and store with Meter.
note: If voltage is too high, Meter will sound.
ncV (non-contact ac Voltage)
Move the Probe Tip of the Clamp close to the
unshielded conductor or hot side of outlet. If detected
voltage is >110VAC, the NCV Indicator will turn on.
WarninG! tO preVent SeriOuS inJury: even if
no indication is given, voltage may still be present.
Do not rely solely on NCV detection to
determine the presence of voltage.
DC
700
TM
tM

Page 12 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
Frequency/Duty cycle Measurement
Measure frequency up to 10kHz.
note: Frequency and duty cycle modes cannot be used while in minimum and maximum value mode.
in current Mode:
WarninG! tO preVent SeriOuS
inJury: Remove test leads before taking
measurements with the Current Clamp.
1. Turn the Rotary Switch to the 600
or 1000 position, depending on the
amperage of the conductor under test.
2. Press the Clamp Trigger to open the Current
Clamp and insert conductor inside the jaws.
3. Press MODe/inruSH until Hz is displayed.
4. Read measured frequency or
duty cycle on the Display.
5. When testing is complete, turn
Rotary Switch to OFF, and store Meter.
note: Current test range is 100Hz-10kHz.
in Voltage/Frequency Mode:
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the V Hz%
or LoZ V Hz % position.
3. Press MODe/inruSH until Hz is displayed.
4. Connect the Test Leads across
the circuit to be measured.
5. Read measured frequency or
duty cycle on the Display.
6. When testing is complete, turn Rotary Switch to
OFF, remove Test Leads and store with Meter.
note: Frequency test range is
100Hz-100kHz. If the frequency is lower than
100.0Hz, 00.0 is shown on the Display.
note: If the duty cycle is less than 10%,
0.0 is displayed. If the duty cycle is greater
than 94.9%, OL is displayed.
resistance Measurement
Measure circuit resistance up to 60M Ohms.
WarninG! tO preVent SeriOuS
inJury: To prevent electric shock, turn off
all power and fully discharge capacitors on
the circuit under test before measuring.
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the
Ω cap position.
3. Carefully touch exposed conductors
with tips of probes.
4. Read measured resistance on the Display.
5. When testing is complete, turn Rotary Switch to
OFF, remove Test Leads and store with Meter.
note: Sometimes the resistor value and measured
resistance differ. This is due to the Meter’s output test
current going through all possible paths between leads.
note: For resistance measurements above 1MΩ,
allow a few seconds to get a steady reading.
note: When leads are disconnected or
measurement is out of range, OL is displayed.
tM

Page 13For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
continuity Measurement
Test continuity between two points of a circuit.
WarninG! tO preVent SeriOuS
inJury: To prevent electric shock, turn off
all power and fully discharge capacitors on
the circuit under test before measuring.
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the
Ω cap position.
3. Press MODe/inruSH until is displayed.
4. Connect the test leads across the
circuit to be measured.
5. Read measured resistance on the
Display. If the measured resistance is
less than 50Ω, Meter will sound.
6. When testing is complete, turn Rotary Switch to
OFF, remove Test Leads and store with Meter.
note: If Test Leads are open or the resistance
of the circuit is over 50Ω, OL is displayed.
Diode Measurement
Test voltage drop in diodes.
WarninG! tO preVent SeriOuS
inJury: To prevent electric shock, turn off
all power and fully discharge capacitors on
the circuit under test before measuring.
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the
Ω cap position.
3. Press MODe/inruSH until is displayed.
4. Connect red probe to diode’s anode
and black probe to its cathode.
5. Read measured forward-biased
voltage drop on the Display.
note: If the test leads are reversed
or open, OL is displayed.
6. When testing is complete, turn Rotary Switch to
OFF, remove Test leads and store with Meter.
tM

Page 14 For technical questions, please call 1-800-444-3353. Item 59456
SaFety OperatiOn MaintenanceSetup
capacitance Measurements
Measure capacitance up to 100mF.
WarninG! tO preVent SeriOuS inJury:
Turn off all power and fully discharge capacitors
on the circuit under test before measuring.
1. Plug black test lead into cOM Jack. Plug
red test lead into input Jack.
2. Turn the Rotary Switch to the
Ω cap position.
3. Press MODe/inruSH until nF is displayed.
4. Carefully touch capacitor leads with tips of probes.
5. Read measured capacitance on the Display.
note: Large capacitance values can
take up to 6 seconds to display.
6. When testing is complete, turn Rotary Switch to
OFF, remove Test leads and store with Meter.
temperature Measurements
WarninG! tO preVent SeriOuS inJury:
Turn off all power and fully discharge capacitors
on the circuit under test before measuring.
1. Plug Temperature Probe leads into cOM and
input Jacks, observing correct polarity.
2. Turn the Rotary Switch to the
teMp °c °F position.
3. Press MODe/inruSH until °c or °F is displayed.
4. Carefully touch temperature probe head
to test area until temperature stabilizes
(approximately 30 seconds).
5. Read measured temperature on the Display.
6. When testing is complete, turn
Rotary Switch to OFF, remove Temperature
Probe leads and store with Meter.
cautiOn! tO preVent inJury: Make sure
Temperature Probe is removed from Meter before
selecting another measurement function.
tM

Page 15For technical questions, please call 1-800-444-3353.Item 59456
SaFetyOperatiOnMaintenance Setup
Maintenance and Servicing
procedures not specifically explained in this manual must
be performed only by a qualified technician.
cleaning, Maintenance, and Lubrication
1. Wipe unit with a dry, lint-free cloth. Do
not use solvents or abrasives.
2. Remove batteries if not in use for long periods.
3. Store unit in a dry location.
4. Other than the batteries, there are no
replaceable parts on this unit. repairs should
be done by a qualified technician.
Battery replacement
If the sign appears on the Display,
the battery should be replaced.
1. Remove Test Leads from the Meter.
2. Turn the unit over.
3. Remove screw on battery cover.
4. Open battery compartment.
5. Remove batteriest and replace with the same.
note: Do not install old and new batteries together.
Do not install alkaline, carbon-zinc or rechargeable
batteries together. Position batteries in proper
polarity. Do not use swollen or leaking batteries.
6. Replace battery cover and screw to secure.
calibration
Have the Meter calibrated by a qualified technician every year.
A Meter that is not calibrated yearly may not yield accurate results.
record product’s Date code Here:
note: if product has no date code, record month and year of purchase instead.
note: Replacement parts are not available for this item. Reference UPC 193175471468.

26677 agoura road • calabasas, ca 91302 • 1-800-444-3353
tM
3-year LiMiteD Warranty
This DOYLE product is warranted to the original purchaser to be free from defects in materials and workmanship for a
period of three (3) years beginning on the date of purchase. To obtain warranty service, visit your local Harbor Freight
retail store. Warranty registration is not required. The product or part must be returned with proof of purchase (e.g.
in-store receipt or packing slip/invoice) and may require shipment by purchaser to a service center at purchaser’s
expense. If our inspection verifies a covered defect in materials or workmanship during the warranty period, we will,
at our option, repair or replace the defective product. We will return repaired products within a reasonable time at
our expense, but if we determine that there is no defect, or that the defect resulted from causes not within the scope
of our warranty, then we will return the product to you if you pay return shipping costs. Fraudulent returns or claims
will be denied. The repair or replacement described in this warranty shall be your sole and exclusive remedy.
This warranty does not cover any failure or damage that we determine is due directly or indirectly to:
• normal wear and tear, including, without limitation to, batteries, fuses, test leads, thermocouples, and other wear
items
• accident, misuse, abuse, rental, use not for the intended purpose, or use not in accordance with the product
manual
• modification, alteration, unauthorized repair, use of equipment or components we did not supply, improper
installation
• any other failure not arising from defective materials or workmanship
THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES, WRITTEN OR
ORAL, AND ANY IMPLIED WARRANTIES ARE DISCLAIMED TO THE EXTENT PERMITTED BY LAW AND
OTHERWISE LIMITED TO THE DURATION OF THE EXPRESS WARRANTY HEREIN. HARBOR FREIGHT
SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR ANY INCIDENTAL, INDIRECT, SPECIAL,
CONSEQUENTIAL, OR PUNITIVE DAMAGES OR COSTS ARISING FROM THIS WARRANTY OR THE
USE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED
WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THESE LIMITATIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC
LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.