Lawn
Sprinkler
Pump
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
© 1998 Wayne Home Equipment
Description
This pump is a high capacity, self-prim-
ing centrifugal pump suitable for lawn
sprinkling or other applications where
large quantities of water are required.
Flammable liquids such as gasoline,
chemicals or corrosive liquids should
never be used with this pump
.
Safety Guidelines
This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
may result in minor or moderate injury.
Notice indicates
important infor-
mation, that if not followed, may cause
damage to equipment.
General Safety Information
1. Read these rules and
instructions carefully.
Failure to follow these
instuctions could
cause serious bodily
injury and/or property damage.
NOTICE
!
CAUTION
!
WARNING
!
DANGER
Operating Instructions and Parts Manual WLS Series
This pump is non-
submersible.
Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil,
kerosene, etc. Do not use in a flamma-
ble and/or explosive atmosphere.
Personal injury and/or property dam-
age could result.
This pump is not
designed to handle
salt water, brine, laundry discharge or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will
void warranty.
All wiring must be per-
formed by a qualified
electrician. The pump
must be installed in com-
pliance with all local and national
codes.
2. Connect this product to a grounded
circuit equipped with a ground
fault interruptor device.
3. Before installing this product, have
the electrical circuit checked by an
electrican to ensure proper ground-
ing.
4. BE CERTAIN the pump
power source is dis-
connected before
installing or servicing
pump.
5. Check motor voltage setting on
motor endplate and make sure the
line voltage of the electrical current
supply is correct.
6. Be sure the water source and piping
is clear of sand, dirt and scale.
!
WARNING
NOTICE
!
WARNING
!
DANGER
320200-001 6/98
Debris will clog pump and void war-
ranty.
7. Failure to protect pump and piping
from freezing could cause severe
damage and will void the warranty.
8. Do not run pump dry. Follow prim-
ing instructions.
Installation
Protect pump from the elements by
installing in a basement, garage, tool
shed or pump house. Install the pump so
the centerline of the pump is as close as
possible to the water level. Keep installa-
tion area clear to provide access for ser-
vice and maintenance. Protect the pump
against flooding and excess moisture.
Make sure the pump has adequate ven-
tilation. The surrounding temperature
should not exceed 100
o
F (38
o
C) or nui-
sance tripping of the motor may occur.
PUMP PIPING INSTALLATION
Use new pipe for best results.
Galvanized or plastic pipe can be used.
When using galvanized pipe, provide
independent supports for both suction
and discharge piping near the pump to
avoid strain on the pump. Minimize use
of elbows and fittings to reduce friction
loss. Refer to the friction loss chart for
specific information.
Increase diameter of suction or dis-
charge piping if length is over 50 feet.
SUCTION PIPING
Install foot valve
or strainer screen
over intake of suction piping.
Never use pipe smaller than 2” in
diameter for suction piping. The suc-
tion pipe must be kept free of air leaks.
!
WARNING
MANUAL
1
2
3
4
5
6
8
7
9
10
11
1 Motor 32031-001 32015-001 32020-001 32021-001 1
2 Tornillo Hex. de 9,5 mm (3/8”) -16 x 2,5 cm (1”) 16334 16334 16334 16334 4
3 Placa selladora 41011-001 41011-001 41011-001 41011-001 1
4 Ensamblaje del sello del eje 15559-002 15559-002 15559-002 15559-002 1
5 Propela 29806-001 29805-001 29804-001 29803-001 1
6 Difusor 29807-001 29807-001 29807-001 29807-001 1”)
7 Tornillo tipo Phillips de 10-24 x 2,5 cm (1”) 67017-001 67017-001 67017-001 67017-001 3
8 Anillo cuadrado 19013-001 19013-001 19013-001 19013-001 1
9 Voluta 41010-001 41010-001 41010-001 41010-001 1
10 Tornillo Hex. de 11,1 mm (7/16”) -16 x 3,2 cm (1.25”) 67018 67018 67018 67018 4
11 Tapón de 6,4 mm (1/4”) NPT 16314-002 16314-002 16314-002 16314-002 1
Para ordenar repuestos comuníquese con el distribuidor
más cercano a su domicilio
Sírvase suministrarnos la siguiente
información:
-Número del modelo
-Número de Serie (de haberlo)
-Descripción y número del repuesto
según la lista de repuestos
Puede escribirnos a:
Wayne Home Equipment
100 Production Drive
Harrison, OH 45030 U.S.A.
No. de Para los Modelos:
Ref. Descripción WLS75 WLS100 WLS150 WLS200 Ctd.
Garantía Limitada
Durante un año a partir de la fecha de compra del comprador original, la compañía Wayne Home Equipment Division ("Wayne") reparará o reemplazará, según
lo decida, cualquier pieza de esta bomba de desagüe o bomba de agua que se encuentre defectuosa debido a materiales usados o procesos de manofactura.
Sírvase llamar a la compañía Wayne (800-237-0987, desde EUA) para recibir instrucciones al respecto o comuníquese con el distribuidor más cercano a su domi-
cilio. Para hacer reclamos bajo esta garantía deberá suministrarnos el número del modelo y el número de serie del producto. El comprador será responsable de
pagar todos los gastos de flete para enviar las piezas o el producto para que sean reparados o reemplazados.
Esta garantía Limitada no cubre los daños que sufra el producto debido a accidentes, abusos, usos inadecuados, negligencia, instalación incorrecta, mantenimien-
to inadecuado o haberse utilizado sin seguir las instrucciones escritas suministradas por la compañía Wayne.
NO EXISTEN OTRAS GARANTIAS EXPRESAS. LAS GARANTIAS IMPLICITAS INCLUYENDO GARANTIAS EN RELACION AL MERCADEO O USOS ESPECIFI-
COS ESTAN LIMITADAS A UN AÑO A PARTIR DE LA FECHA DE COMPRA. ESTA ES LA UNICA GARANTIA DISPONIBLE Y TODAS LAS REPONSABILIDADES
CIVILES, DIRECTAS O INDIRECTAS, O GASTOS POR DAÑOS INDIRECTOS O CONSECUENTES QUEDAN EXCLUIDOS.
Algunos estados no permiten que se establezcan límites en la duración de las garantías implicitas o no permiten que se excluyan ni se establezcan límites en los
daños por incidentes o consecuencias, por lo tanto los límites antes mencionados podrían ser no válidos. Esta Garantía Limitada le otorga derechos legales
especificos, y usted también puede tener otros derechos que varian de un Estado a otro
.
En ningún caso, bien sea por ruptura del contrato de la garantía, responsabilidad civil (incluyendo negligencia) u otra causa, Wayne o sus distribuidores serán
responsables pon daños especiales, consecuentes ni circunstanciales ni penales, incluyendo, pero no limitados a la pérdida de ganancias, pérdida de uso del pro-
ducto o equipos asociados, daños a equipos asociados, costos de capitales, costos para substituir productos, costos para substituir o reemplazar servicios, costos
por pérdida de productividad, o reclamos de clientes del comprador por dichos daños.
DEBE conservar el recibo de compra con esta garantía. En caso de que necesite hacer un reclamo bajo esta garantía, DEBERA enviarnos una copia del recibo
junto con el material o correspondencia. Sírvase comunicarse con la compañía Wayne (800-237-0987, en EUA) para recibir autorización e instrucciones para enviar
el producto.
NO ENVIE ESTA GARANTIA A WAYNE. Use este documento sólo para mantener sus records.
NO DEL MODELO _______________ NO DE SERIE __________________________ FECHA DE INSTALACION _____________
ANEXE SU RECIBO AQUI
Manual de Instrucciones y Lista de Repuestos

Problema Posible(s) Causa(s) Acción a Tomar
Diagnóstico de Averías
El motor no funciona
El motor se recalieenta
y el sistema de protec-
ción lo apaga
El motor funciona pero
la bomba no suminis-
tra agua
Nota: Ante todo
chequée el sistema de
cebado. Sáquele el
tornillo del sistema de
cebado y vea si el orifi-
cio está lleno de agua.
La bomba no le sumi-
nistra agua a la capaci-
dad máxima
1. El interruptor está en “off”
(apagado)
2. El fusible está quemado
3. El interruptor está dañado
4. Los cables eléctricos del
motor están flojos,
desconectados o mal conec-
tados
1. Los cables del motor están
mal conectados
2. El voltaje es muy bajo
3. La envoltura de la bomba
no está bien ventilada
1. Después de instalar la bomba
en un sitio dife-rente, la
bomba no completó el proce-
so de cebado debido a:
a. Cebado incorrecto
b. Fugas de aire
c. Fugas en la válvula de pie
2. La bomba perdió el cebado
debido a:
a. Fugas de aire
b. El nivel de agua inferior
a la distancia de succión
de la bomba
3. La propela está obstruída
4. La válvula de chequeo o la
válvula de pie están atas-
cadas en la posición cerrada
5. Las tuberías están conge-
ladas
6. La válvula de pie y/o el
colador están enterrados en
arena o lodo
1. El nivel de agua del pozo es
inferior a lo estimado
2. Las tuberías de acero (de
usarlas) están oxidadas o
alcalizadas, ocasionando
fricción excesiva
3. Las tuberías son muy
pequeñas
1. Cerciórese de que el interruptor esté en “ON” (encendido)
2. Reemplace el fusible
3. Reemplace el interruptor
4. Vea las instrucciones del alambrado. Chequée y conecte bien
todos los alambres
El voltaje del capacitador podría
ser peligroso. Para descargarlo
tóquelo con un desarmador aislado. CERCIORESE de sostener el
desarmador por el mango aislado cuando esté haciendo contacto
con los terminales del capacitador.
1. Vea las instrucciones del alambrado
2. Consúltele a la compañía de eléctricidad. Instale alambres más
resistentes si los disponibles no son adecuados (Vea la tabla de
almabrado)
3. Cerciórese de que la bomba tenga suficiente ventilación para
enfriar el motor
1. Instalación nueva:
a. Siga las instrucciones para cebar la bomba
b. Chequée todas las conecciones de la línea de succión
c. Reemplace la válvula de pie
2. Instalaciones actuales:
a. Chequée todas las conecciones de la línea de succión y el
sello del eje
b. Baje la línea de succión y cebe la bomba una vez más. Si no
logra alcanzar el nivel del agua en el tanque con la tubería
de succión, deberá utilizar una bomba para pozos profun-
dos
3. Limpie la propela
4. Reemplace las válvulas de chequeo o de pie
5. Descongele las tuberías. Entiérrela por debajo de la línea de
congelamiento. Caliente el pozo o el sitio donde tenga alma-
cenada la bomba
6. Coloque la válvula de pie y/o el colador por encima del fondo
del pozo
1. Quizás necesite usar una bomba de propulsión para pozos
profundos (si el agua está a más de 7,6 metros (25’)
2. Reemplace las tuberías con tuberías de plástico donde sea
posible, de lo contrario use tuberías de acero nuevas
3. Use tuberías más anchas
!
ADVERTENCIA
Serie WLS
19 Sp
Manual de Instrucciones y Lista de Repuestos
2
Operating Instructions and Parts Manual
Installation (Continued)
For horizontal runs, lay pipe from the
water source so the upward slope is at
least 1/2” per foot. This eliminates
trapped air. The threaded inlet of the
pump is 2” NPT.
Do not install suc-
tion piping near
swimming areas.
DISCHARGE PIPING
Install a 1-1/2” pipe tee in the pump
discharge to allow easy priming. Plug
the end of the tee opposite the pump
to allow the branch piping to go to the
spray nozzles (See Figure 1). Remove
the pipe plug to fill the pump with
water for priming.
CONNECTION TO WATER SOURCE
The maximum vertical suction lift from
pump to the water level is 25 feet.
DRILLED WELL
1. Install a foot valve on the first sec-
tion of pipe (see Figure 2).
2. Lower the pipe into the well.
3. Add pipe until the foot valve is 10
feet below the lowest anticipated
water level.
Leaking joints or couplings will allow
air to leak into the pipe and cause poor
pump operation. Make sure to use
pipe joint compound or Teflon
®
tape on
all pipe connections.
!
DANGER
Locate foot valve
no closer than 2
feet from the bottom of the well so
sand or sediment is not drawn into the
system.
4. After the proper depth is reached,
install a well seal or pitless adapter
to support the pipe.
5. Slope the horizontal pipe upward
toward the pump to eliminate trap-
ping air.
6. When using a foot valve, a priming
tee and plug above the well seal is
recommended.
DRIVEN WELL
1. Drive the point several feet below
the water table.
NOTE: A packer-type foot valve can be
installed in the well (See Figure 3). This
type of foot valve allows the well pipe
to be filled with water when priming
and makes the inlet pipe much easier
to test for leaks. Follow the manufac-
turer’s instructions when installing the
packer-type foot valve.
As an alternative, an in-line check valve
can be used with a driven well (See
Figure 4).
!
CAUTION
It may be necessary to supply the
pump with multiple well points to
maintain the high flow capability of
this pump. Consult with a plumbing
professional for appropriate materials
and installation instructions.
Leaking joints or couplings will allow
air to leak into the pipe and cause poor
pump operation. Make sure to use
pipe joint compound or Teflon
®
tape on
all pipe connections.
Lawn Sprinkler Pump
To Pump
Well Seal
Well
Casing
Foot Valve
Figure 2
Drive Point
Figure 3
To Pump
Packer Type
Foot Valve
To Pump
Inline Check Valve
Drive Point
Figure 4
Pipe Plug
To Spray
Nozzles
Short
Section
of Pipe
1-1/2” Pipe
Tee
Pump
Figure 1

Manual de Instrucciones y Lista de Repuestos
Bomba para Regar Césped
18 Sp
Funcionamiento
(Continuación)
bomba no comienza a bombear agua
en 10 minutos, apáguela y llénela de
agua limpia una vez más.
Si la bomba no funciona después de
varios intentos, chequée lo siguiente:
1. La distancia vertical entre la bomba
y el nivel de agua no debe ser más
de 7,6 metros (25’).
2. Las tuberías de succión deben estar
apretadas herméticamente.
3. Cerciórese de que la(s) válvula(s) de
las tuberías de descarga o de suc-
ción estén abiertas (de haberlas).
Nunca
use la
bomba si las tuberías de descarga están
cerradas u obstruídas. El agua dentro
de la bomba podría hervir y dañar la
bomba.
Mantenimiento
El motor de la bomba debe mantenerse
bien ventilado. Los cojinetes del motor
vienen de fábrica lubricados de por vida.
Éstos no necesitan lubricación adicional.
DURANTE EL INVIERNO
Siempre proteja la bomba y las tuberías
contra temperaturas congelantes. Si
hay peligro de que se congelen, drene
el sistema. Para drenar el sistema:
!
PRECAUCION
1. Quítele el tapón al conector en T de
la tubería de descarga.
2. Quítele el tapón de 6,4 mm (1/4”)
ubicado en la parte inferior del
frente de la bomba.
3. Drene todas las tuberías ubicadas
por debajo de la línea de conge-
lamiento.
Capacidad de las Bombas de 3/4 CP en Litros/Hora
Distancia Presión de Trabajo (bar)
en Metros 0,69 1,38 2,07
Capacidad de las Bombas de 1 CP en Litros/Hora
Distancia Presión de Trabajo (bar)
en Metros 0,69 1,38 2,07
Capacidad de las Bombas de 1-1/2 CP en Litros/Hora
Distancia Presión de Trabajo (bar)
en Metros 0,69 1,38 2,07 2,76
Capacidad de las Bombas de 2 CP en Litros/Hora
Distancia Presión de Trabajo (bar)
en Metros 0,69 1,38 2,07 2,76
3,2 cm (1-1/4”) 0,179 0,269 0,379 0,648 0,972
3,8 cm (1-1/2”) 0,083 0,179 0,303 0,462 0,648 1,096
5,1 cm (2”) 0,041 0,055 0,089 0,138 0,193 0,324 0,489 0,689
6,4 cm (2-1/2”) 0,041 0,055 0,083 0,089 0,207 0,289
* Multiplique por 1,8 si usa tubos de acero
Pérdida debido a la fricción por cada 30,5 metros de tubos de plástico bar *
Diám. del (Litres por Hora)
Tubo 4,542 5,678 6,814 9,085 11,356 13,627 18,170 22,712 27,255
1,5 14,761 12,566 8,781
3 14,308 11,810 7,949
4,6 13,627 11,015 4,504
6,1 12,302 10,107 3,747
7,6 11,394 9,690 3,179
1,5 16,693 14,838 9,728
3 15,823 13,324 8,706
4,6 14,498 12,643 6,738
6,1 13,930 11,583 4,391
7,6 12,643 10,296 4,769
1,5 18,132 16,958 13,173 7,797
3 17,450 16,315 12,075 5,753
4,6 16,352 15,293 10,977 0
6,1 14,763 14,081 10,144 0
7,6 14,422 12,491 9,047 0
1,5 22,636 21,046 16,315 11,583
3 20,479 19,759 15,482 10,901
4,6 19,797 18,851 14,763 9,728
6,1 15,595 14,535 13,286 8,365
7,6 15,065 13,627 12,491 0
Operation
Never run the
pump dry. Running
pump without water may cause seal
damage. Fill the pump with water
before starting.
PRIMING THE PUMP
After pump installation is complete,
the pump must be primed. Remove the
pipe plug in the discharge piping and
fill the pump and suction pipe with
clean water. Turn power to pump on. If
the pump does not pump water in 10
minutes, turn off the pump and refill
with clean water.
If the pump does not operate after
repeated attempts, check the follow-
ing:
1. Vertical distance of pump to water
level must not be over 25 feet.
2. Suction piping must be air tight.
3. Be sure valve(s) are open if used in
discharge or suction piping.
Never run the
pump with a
closed or clogged discharge. The water
inside the pump could boil and damage
the pump.
Maintenance
Maintain adequate ventilation for the
pump motor. The motor bearings are
permanently lubricated at the factory.
Additional lubrication is not required.
!
CAUTION
!
CAUTION
3
Operating Instructions and Parts Manual
Dug Well, Cistern, Lake And
Spring Installation
1. Install a foot valve on the inlet pipe
and lower into the water.
Locate foot valve
no closer than 2
feet from the bottom of the water
source so sand or sediment is not
drawn into the system.
NOTE: When a lake is used for the
water supply, make sure the suction
pipe is deep enough to be submerged
at all times. Slope the pipe upward
toward the pump to eliminate trap-
ping air. The pipe must be removed
during winter months or protected
against freezing.
Protect the pipe
from damage by
swimmers and boaters.
Electrical Connections
Connect the pump to a separate elec-
trical circuit with a dedicated circuit
breaker. Refer to the electrical specifi-
cations in wiring chart for recommend-
ed circuit breaker and wire size.
Install and maintain wiring for this
pump in accordance with the National
Electrical code and all applicable local
electrical codes.
The motor must be grounded by con-
necting a copper conductor to the
!
WARNING
!
CAUTION
grounding screw provided within the
wiring compartment.
The voltage of power supply must
match the voltage of the pump. The
WLS75, WLS100 and WLS150 have dual
voltage motors preset at the factory to
230 volts. The motors can be converted
to 115 volts by turning the voltage
selector to the desired voltage (See
Figure 5). Use a needle nose pliers to
pull the selector out approximately
1/4”, rotate and then reinsert in correct
position. The WLS200 cannot be con-
verted; the motor is 230 volts only.
WLS Series
115 V
230 V
115 V
230 V
Figure 5 - Voltage Selector
WLS75 3/4 115 13.5 20 12 12 10 10
230 7.0 15 14 14 12 12
WLS100 1 115 14.8 20 12 12 10 10
230 7.4 15 14 14 12 12
WLS150 1-1/2 115 17.0 30 10 10 8 8
230 8.5 15 14 14 12 12
WLS200 2 230 12.0 15 14 14 12 12
Distance in Feet From Motor to Supply
Max. Fuse 0 51 101 201
Load Rating 50 100 200 300
Model HP Volts Amps Amps (AWG Wire Size)
WIRING CHART - RECOMMENDED WIRE AND FUSE SIZES

no se puede modificar; esta bomba
sólo funciona con 230 voltios.
Funcionamiento
Nunca
use la
bomba en seco. El hacerlo podría dañar
los sellos. Llene la bomba de agua
antes de encenderla.
PARA CEBAR LA BOMBA
Después de terminar de instalar la
bomba deberá cebarla. Quítele el
tapón a la tubería de descarga y llene
la bomba y la tubería de succión de
agua limpia. Encienda la bomba. Si la
!
PRECAUCION
17 Sp
Instalación (Continuación)
llenen de agua durante el proceso de
cebar la bomba y le facilita chequear si
hay fugas en la tubería de entrada. Siga
las instrucciones del fabricante para
instalar la válvula de pie tipo packer.
Igualmente, puede usar una válvula de
chequeo incorporada a la línea en los
pozos excavados (Vea la Figura 4).
Quizás sea necesario conectar la
bomba al pozo en varios puntos para
mantener su alta capacidad de flujo.
Consúltele a un plomero profesional
sobre los materiales adecuados y las
instrucciones para instalarla.
Si hay fugas en las conexiones le
entrará aire a las tuberías ocasionando
que la bomba no funcione bien.
Cerciórese de sellar todas las conex-
iones con selladores de tuberías o cinta
de Teflón
®
.
Para instalar la bomba en
pozos excavados, Cisternas,
Lagos y Manantiales
1. Instálele una válvula de pie a la
tubería de entrada y métala dentro
del agua.
No
ubique
la válvula de pie a menos de 0,61 met-
ros del fondo de la fuente de agua
para evitar que entren al sistema resid-
uos de arena u otros sedimentos
NOTA: Si la fuente de suministro de
agua es un lago, cerciórese de que la
!
PRECAUCION
tubería de succión sea suficientemente
larga para que siempre permanezca
sumergida. Incline la tubería hacia arri-
ba en dirección a la bomba para evitar
las acumulaciones de aire. Debe sacar la
tubería durante el invierno para evitar
que se congele.
Proteja
las
tuberías para evitar que personas
nadando o en botes las dañen.
Conecciones Eléctricas
Conecte la bomba a un circuito eléctrico
independiente que tenga un cortacir-
cuito exclusivo. Vea las indicaciones al
respecto en la tabla de especificaciones
del circuito eléctrico y alambrado.
Instale y mantenga el sistema eléctrico
de esta bomba según los códigos
nacionales y locales al respecto.
El motor se debe conectar a tierra con
un conductor de cobre conectado al
tornillo de conexión a tierra suministra-
do en el compartimiento de alambres.
El voltaje de la fuente de suministro
eléctrico debe ser similar al de la bomba.
Los modelos WLS75, WLS100 y WLS150
le ofrecen un sistema de voltaje doble y
vienen de fábrica para funcionar a 230
voltios. Para conectarlas a circuitos de
115 voltios simplemente gire la perilla al
voltaje deseado (Vea la Figura 5). Use
una pinza (alicate) de punta afilada para
halar la perilla aproximadamente un
6,4 mm (1/4”), gírela y colóquela en su
posición correcta. El modelo WLS200
!
ADVERTENCIA
Serie WLS
115 V
230 V
115 V
230 V
Figura 5 - Perilla para Seleccionar
el Voltaje
WLS75 3/4 115 13,5 20 12 12 10 10
230 7,0 15 14 14 12 12
WLS100 1 115 14,8 20 12 12 10 10
230 7,4 15 14 14 12 12
WLS150 1-1/2 115 17,0 30 10 10 8 8
230 8,5 15 14 14 12 12
WLS200 2 230 12,0 15 14 14 12 12
Distancia entre el Motor y la Fuente (en Metros)
Amperios Amperaje de 0 15,5 30,8 61,3
Máximos los fusibles 15,2 30,5 61 91,4
Modelo CP Voltios Amps (Calibre del Alambre AWG )
TABLA DE ALAMBRADO - ALAMBRES Y FUSIBLES RECOMENDADOS
Manual de Instrucciones y Lista de Repuestos
Operating Instructions and Parts Manual
Lawn Sprinkler Pump
4
Maintenance (Continued)
DRAINING FOR WINTER
Always protect pump and piping
against freezing temperatures. If there
is any danger of freezing, drain the sys-
tem. To drain the system:
1. Remove the pipe plug from the dis-
charge tee.
2. Remove the 1/4” plug from the
lower front face of the pump.
3. Drain all piping below the frost line.
5 3900 3320 2320
10 3780 3120 2100
15 3600 2910 1190
20 3250 2670 990
25 3010 2560 840
3/4 HP Pump Capacity in GPH
Lift Operating Pressure (psi)
in Feet 10 20 30
5 4410 3920 2570
10 4180 3520 2300
15 3830 3340 1780
20 3680 3060 1160
25 3340 2720 1260
1 HP Pump Capacity in GPH
Lift Operating Pressure (psi)
in Feet 10 20 30
5 4790 4480 3480 2060
10 4610 4310 3190 1520
15 4320 4040 2900 0
20 3900 3720 2680 0
25 3810 3300 2390 0
1-1/2 HP Pump Capacity in GPH
Lift Operating Pressure (psi)
in Feet 10 20 30 40
5 5980 5560 4310 3060
10 5410 5220 4090 2880
15 5230 4980 3900 2570
20 4120 3840 3510 2210
25 3980 3600 3300 0
2 HP Pump Capacity in GPH
Lift Operating Pressure (psi)
in Feet 10 20 30 40
1-1/4 2.6 3.9 5.5 9.4 14.1
1-1/2 1.2 1.9 2.6 4.4 6.7 9.4 15.9
2 0.6 0.8 1.3 2.0 2.8 4.7 7.1 10.0
2-1/2 0.6 0.8 1.2 1.3 3.0 4.2
* Multiply by 1.8 for steel pipe
psi Friction Loss in 100 Feet of Plastic Pipe*
Pipe (Gallons per Hour)
Size 1200 1500 1800 2400 3000 3600 4800 6000 7200

16 Sp
Instalación (Continuación)
Si la longitud de las tuberías es más de
15,2 metros (50’) debe aumentar el
diámetro de las tuberías de descarga.
TUBERIAS DE SUCCION
Instálele
una
válvula de pie o un colador en la entra-
da de la tubería de succión.
Nunca use tuberías de menos de 5,1 cm
(2”) de diámetro en el sistema de succión.
Debe evitar las fugas de aire en las
tuberías de succión.
Las tuberías horizontales se deben instalar
de modo que tengan una inclinación hacia
arriba de por lo menos 12,7 mm (1/2”) por
cada pie de longitud. Ésto elima la acumu-
lación de aire en las tuberías. El orificio de
entrada donde se conecta la tubería a la
bomba es de 5,1 cm (2”) NPT.
No insta-
le las
tuberías de succión cerca de áreas
donde se nade.
TUBERIAS DE DESCARGA
Instale un conector en T de 3,8 cm en el
orificio de salida para facilitar el proce-
so de cebar la bomba. Colóquele un
tapón en el ortificio del lado opuesto a
la bomba de modo que el agua se dirija
hacia las regaderas (Vea la Figura 1).
Quítele el tapón cuando vaya a llenar
de agua la bomba para cebarla.
!
PELIGRO
!
ADVERTENCIA
CONEXION A LA FUENTE DE AGUA
La altura máxima de succión entre la
bomba y el nivel de agua es de 7,6 met-
ros (25’).
POZOS TALADRADOS
1. Instale una válvula de pie en la
primera sección de la tubería (vea la
Figura 2).
2. Coloque la tubería dentro del pozo.
3. Añada tubos hasta que la válvula de
pie esté a 3,05 metros por debajo del
nivel de agua más bajo anticipado.
Si hay fugas en las conexiones le entrará
aire a las tuberías ocasionando que la
bomba no funcione bien. Cerciórese de
sellar todas las conexiones con selladores
de tuberías o cinta de Teflón
®
.
Para evi-
tar la
entrada de arena o sedimentos al sis-
tema la distancia mínima entre la
válvula de pie y el fondo del pozo es de
2 pies del fondo del pozo.
4. Después de alcanzar la profundiad
adecuada, instale un sello para
pozos o un adaptador para pozos
sin fondo para sostener las tuberías.
5. Incline las tuberías horizontales
hacia arriba para evitar la acumu-
lación de aire.
!
PRECAUCION
6. Cuando use una válvula de pie, es
recomendable que instale una
conexión en T y un tapón antes del
sello del pozo.
POZOS EXCAVADOS
1. Excave varios pies por debajo del
nivel de agua freática.
NOTA: Puede instalar una válvula de
pie tipo packer en el pozo (Vea la
Figura 3). Este tipo de válvula de pie
permite que la tuberías en el pozo se
Bomba para Regar Césped
Hacia la bomba
Sello del pozo
Paredes
internas
del pozo
Válvula de
pie
Figura 2
Perforador
Figura 3
Hacia la Bomba
Válvula de
Pie Tipo
Packer
Hacia la Bomba
Válvula de Chequeo
Incorporada a la Línea
Perforador
Figura 4
Tapón para
tuberías
Hacia las
regaderas
Tubería
Corta
Conector
en T de
3,8 cm
Bomba
Figura 1
Manual de Instrucciones y Lista de Repuestos
Symptom Possible Cause(s) Corrective Action
Troubleshooting Chart
Motor will not run
Motor runs hot and
overload kicks off
Motor runs but no
water is delivered
Note: Check prime
before looking for
other causes. Unscrew
priming plug and see if
water is in priming
hole.
Pump does not deliver
water to full capacity
1. Disconnect switch is off
2. Fuse is blown
3. Starting switch is defective
4. Wires at motor are loose,
disconnected or wired
incorrectly
1. Motor is wired incorrectly
2. Voltage is too low
3. Pump house not properly
vented
1. Pump in new installation
did not pick up prime
through:
a. Improper priming
b. Air leaks
c. Leaking foot valve
2. Pump has lost prime
through:
a. air leaks
b. water level below suc-
tion of pump
3. Impeller is plugged
4. Check valve or foot valve
is stuck in closed position
5. Pipes are frozen
6. Foot valve and/or strainer
are buried in sand or mud
1. Water level in well is
lower than estimated
2. Steel piping (if used) is
corroded or limed, causing
excess friction
3. Piping is too small in size
1. Be sure switch is on
2. Replace fuse
3. Replace starting switch
4. Refer to wiring instructions. Check and tighten all wiring
Capacitor voltage may be hazardous. To
discharge capacitor, touch short capacitor
terminals with an insulated screwdriver. BE SURE to hold handle
of screwdriver while making contact with capacitor terminals.
1. Refer to wiring instructions
2. Check with power company. Install heavier wiring if wire size
is too small (See wiring chart)
3. Be sure pump has sufficient ventilation to cool the motor
1. New installation:
a. Re-prime according to instructions
b. Check all connections on suction line
c. Replace foot valve
2. Existing installations:
a. Check all connections on suction line and shaft seal
b. Lower suction line into water and re-prime. If receding
water level in well exceeds suction lift, a deep well pump is
needed
3. Clean impeller
4. Replace check valve or foot valve
5. Thaw pipes. Bury pipe below frost line. Heat pit or pump
house
6. Raise foot valve and/or stainer above well bottom
1. A deep well jet pump my be needed (over 25 ft. (7.6M) to
water)
2. Replace with plastic pipe where possible, otherwise with new
steel pipe
3. Use larger piping
!
WARNING
Operating Instructions and Parts Manual
WLS Series
5

Bomba para
Regar
Césped
Sírvase leer y guardar estas instrucciones. Lea con cuidado antes de tratar de armar, instalar, manejar o darle servicio al producto descrito en
este manual. Protéjase Ud. y a los demás observando todas las reglas de seguridad. El no seguir las instrucciones podría resultar en heridas y/o
daños a su propiedad. Guarde este manual como referencia.
© 1998 Wayne Home Equipment
Descripción
Estas bombas centrifugas, de alta
capacidad, con sistema de cebado
automático, están diseñadas para regar
césped u otras aplicaciones donde se
requieran grandes cantidades de agua.
Esta bomba no se debe utilizar para
rociar líquidos inflamables tales como
gasolina, químicos o líquidos corrosivos.
Medidas de seguridad
Este manual contiene información que
es muy importante que sepa y com-
prenda. Esta información se la suminis-
tramos como medida de SEGURIDAD y
para EVITAR PROBLEMAS CON EL
EQUIPO. Debe reconocer los siguientes
símbolos.
Ésto le
indica
que hay una situación inmediata que
LE OCASIONARIA la muerte o heridas
de gravedad.
Ésto le
indica
que hay una situación que PODRIA oca-
sionarle la muerte o heridas de
gravedad.
Ésto le
indica
que hay una situación que PODRIA oca-
sionarle heridas no muy graves.
Ésto le
indica
una información importante, que de no
seguirla, le podría ocasionar daños al
equipo.
Informaciones Generales de
Seguridad
1. Lea estas instrucciones
con cuidado. Si no sigue
estas instrucciones
podría sufrir heridas de
gravedad y/o daños a su propiedad.
AVISO
!
PRECAUCION
!
ADVERTENCIA
!
PELIGRO
Manual de Instrucciones y Lista de Repuestos Serie WLS
Esta
bomba
no es sumergible.
Úsela sólo para bombear
agua limpia. No la use para
bombear líquidos inflam-
ables o explosivos tales como gasolina,
combuestibles, Kerosene, etc. No la use
en atmósferas inflamables o explosi-
vas. Ésto podría ocasionarle heridas y/o
daños a su propiedad.
Esta
bomba
no está diseñada para bombear agua
salada, salmuera, agua con detergentes
o para ningún tipo de aplicación donde
el agua pueda contener químicos cáus-
ticos y/o desperdicios. Ésto podría
dañar la bomba y cancelaría la garan-
tía.
Todos los trabajos de alam-
brado los debe hacer un elec-
tricista calificado.
2. Conecte esta bomba a un circuito
conectado a tierra que esté equipa-
do con un interruptor de
desconexión automática.
3. Antes de instalar esta bomba, un
electricista calificado debe chequear
el circuito eléctrico para verificar
que esté conectado a tierra ade-
cuadamente.
4. CERCIORESE de que la
bomba esté desconecta-
da del tomacorrientes
antes de instalarla o
darle servicio.
5. Chequée el voltaje indicado en la
placa del motor y cerciórese de que
el voltaje de la corriente eléctrica
sea el adecuado.
!
ADVERTENCIA
AVISO
!
ADVERTENCIA
!
PELIGRO
320200-001 6/98
6. Cerciórese de que el agua
suministrada y las tuberías no ten-
gan residuos de arena, impurezas o
scale. Los residuos de basura atas-
carían la bomba y la garantía
quedaría cancelada.
7. Evite que la bomba y las tuberías se
congelen porque si ésto ocurre podría
ocasionarle daños severos a la bomba
y la garantía quedaría cancelada.
8. No encienda la bomba antes de
cebarla. Siga las instrucciones al
respecto.
Instalación
Proteja la bomba contra las inclemencias
del tiempo instalándola en el sótano,
garaje o cobertizo. Instálela de modo
que el centro de la bomba esté lo más
cerca posible al nivel de agua. Mantenga
el área despejada de modo que esté
accesible para darle servicio y mante-
nimiento. Proteja la bomba contra inun-
daciones y excesos de humedad.
Cerciórese de que la bomba tenga ven-
tilación adecuada. La temperatura
ambiental no debe exceder 38
o
C (100
o
F)
o el motor se puede comenzar a apagar
constantemente.
INSTALACION DE LAS TUBERIAS
Use tuberías nuevas para obtener
mejores resultados. Puede usar tuberías
galvanizadas o plásticas. Si utiliza
tuberías galvanizadas, debe instalarles
soportes independientes tanto a las
tuberías de succión como a las de descar-
ga, lo más cerca posible a la bomba,
para evitar que ésta se fuerce excesiva-
mente. Reduzca el uso de codos y conec-
tores para reducir la pérdida debido a
fricción. Vea la información especifica al
respecto en la tabla de fricción.
15 Sp
1
2
3
4
5
6
8
7
9
10
11
Operating Instructions and Parts Manual
1 Motor 32031-001 32015-001 32020-001 32021-001 1
2 3/8”-16 x 1” Hex cap screw 16334 16334 16334 16334 4
3 Sealplate 41011-001 41011-001 41011-001 41011-001 1
4 Shaft seal assembly 15559-002 15559-002 15559-002 15559-002 1
5 Impeller 29806-001 29805-001 29804-001 29803-001 1
6 Diffuser 29807-001 29807-001 29807-001 29807-001 1
7 10-24 x 1” Phillips screw 67017-001 67017-001 67017-001 67017-001 3
8 Square ring 19013-001 19013-001 19013-001 19013-001 1
9 Volute 41010-001 41010-001 41010-001 41010-001 1
10 7/16”-16 x 1.25” Hex cap screw 67018 67018 67018 67018 4
11 1/4” NPT Sq. hd. pipe plug 16314-002 16314-002 16314-002 16314-002 1
For Replacement Parts, call 1-800-237-0987
Please provide following information:
- Model number
- Serial number (if any)
- Part description and number as
shown in parts list
Address parts correspondence to:
Wayne Home Equipment
100 Production Drive
Harrison, OH 45030 U.S.A.
Ref. Part Number for Models:
No. Description WLS75 WLS100 WLS150 WLS200 Qty.
Limited Warranty
For one year from the date of purchase, Wayne Home Equipment Division ("Wayne") will repair or replace, at its option, for the original purchaser any part
or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne
(800-237-0987) for instructions or see your dealer. Be prepared to provide the model number and the serial number when exercising this warranty. All trans-
portation charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper
maintenance, or failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL
INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential dam-
ages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which
vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special,
consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment,
damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s
customers for such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase
receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE
6

1
2
3
4
5
6
8
7
9
10
11
Instructions d’Utilisation et Manuel de Pièces de Rechange
1 Moteur 32031-001 32015-001 32020-001 32021-001 1
2 Vis d’assemblage hexagonale, 3/8-16 x 1 po 16334 16334 16334 16334 4
3 Plaque de joint 41011-001 41011-001 41011-001 41011-001 1
4 Montage de joint d’arbre 15559-002 15559-002 15559-002 15559-002 1
5 Turbine 29806-001 29805-001 29804-001 29803-001 1
6 Diffuseur 29807-001 29807-001 29807-001 29807-001 1
7 Vis Phillips 10-24 x 1 po 67017-001 67017-001 67017-001 67017-001 3
8 Bague carrée 19013-001 19013-001 19013-001 19013-001 1
9 Volute 41010-001 41010-001 41010-001 41010-001 1
10 Vis d’assemblage hex. 7/16-16 x 1.25 po 67018 67018 67018 67018 4
11 Bouchon mâle de tuyau à t. carré 1/4 po NPT 16314-002 16314-002 16314-002 16314-002 1
Pour Pièces de Rechange, composer 1-800-237-0987
S’il vous plaît fournir l’information suivante:
- Numéro de Modèle
- Numéro de Série (si présent)
- Description et numéro de la pièce
Correspondance:
Wayne Home Equipment
100 Production Drive
Harrison, OH 45030 U.S.A.
Nº Numéro de Pièce pour Modèles:
Réf. Description WLS75 WLS100 WLS150 WLS200 Qté.
Garantie Limitée
Pour un an à compter de la date d’achat, Wayne Home Equipment Division (“Wayne”) vas réparer ou remplacer, à son option, pour l’acheteur
originel n’importe quelle pièce ou pièces de ces Pompes De Puisard ou Pompes À Eau (“Produit”) déterminées défectueuses, par Wayne, en
matière ou en fabrication. S’il vous plaît appeler Wayne (800-237-0987) pour des instructions ou contacter votre marchand. S’assurer d’avoir,
à votre disposition, le numéro du modèle afin d’effectuer cette garantie. Les frais de transportation des Produits ou pièces soumis pour la
réparation ou le remplacement sont la responsabilité de l’acheteur.
Cette Garantie Limitée ne couvre pas les Produits qui se sont fait endommagés en résultat d’un accident, utilisation abusive, mauvais usage,
négligence, l’installation incorrecte, entretien incorrect, ou manque d’utilisation conformément aux instructions écrit de Wayne.
IL N’EXISTE AUCUNE AUTRE GARANTIE OU AFFIRMATION. LES GARANTIES EXPRIMÉES, Y COMPRIS CELLES DE
COMMERCIALISABILITÉ ET D’ADAPTION À UNE FONCTION PARTICULIÈRE, SONT LIMITÉES À UN AN À COMPTER DE LA DATE
D’ACHAT. CECI EST LA REMÈDE EXCLUSIVE ET N’IMPORTE QUELLE RESPONSABILITÉ POUR N’IMPORTE QUEL ET TOUT DOMMAGES
INDIRECTS OU DÉPENSES QUOI QUE SE SOIT EST EXCLUS.
Certaines Provinces n’autorisent pas de limitations de durée pour les garanties implicites, ni l’exclusion ni la limitation des dommages fortuits
ou indirects. Les limitations précédentes peuvent donc ne pas s’appliquer. Cette garantie limitée donne, à l’acheteur, des droits légales pré-
cis, et vous pouvez avoir autres droits légales qui sont variable d’une Province ou d’un État à l’autre.
En aucun cas, soit par suite d’un rupture de contrat de garantie, acte dommageable (y compris la négligence) ou autrement, ni Wayne ou ses
fournisseurs seront responsables pour aucune dommage spéciale, incidentel ou pénal, y compris, mais pas limité à la perte de profits ou
recettes, la perte d’usage des produits ou n’importe quel équipement associé, dommage à l’équipement associé, coût de capital, coût de pro-
duits remplaçants, aménagements, services ou abilité de remplaçement, coût de temps que le produit n’est pas en service, ou la réclamation
des clients de l’acheteur pour ces dommages.
Vous DEVEZ garder votre facture d’achat avec ce bulletin. Il est NÉCESSAIRE d’envoyer une COPIE de la recette d’achat avec le matériel ou
correspondance afin d’effectuer une réclamation de la garantie. S’il vous plaît appeler Wayne (800-237-0987) pour l’autorisation et instruc-
tions concernant le renvoi.
NE PAS ENVOYER, PAR LA POSTE, CE BULLETIN À WAYNE. Utiliser ce bulletin seulement pour vos archives.
Nº DU MODÈLE__________________________ Nº DE SÉRIE________________________________
DATE D’INSTALLATION_____________________________________________
FIXER VOTRE FACTURE ICI
14 Fr
Service Record
État De Service
Hoja de Servicio
7
Lawn Sprinkler Pump
Pompe Pour Arrosoir De Pelouse
Bomba Para Regar Césped
Date
Operating Instructions and Parts Manual
Instructions d’Utilisation et Manuel de Pièces de Rechange
Manual de Instrucciones y Lista de Repuestos
WLS Series
Série WLS
Serie WLS
Date Maintenance performed Replacement components required
Date Entretien Pièces De Rechange Exigées
Fecha Mantenimiento dado Repuestos usados

Symptôme Cause(s) Possible(s) Mesure Corrective
Guide De Dépannage
Le moteur ne fonc-
tionne pas
Le moteur fonctionne
chaud et l’appareil de
déclenchement se
déclenche
Le moteur fonctionne,
mais il n’y a pas de
débit d’eau
Remarque: Vérifier
l’amorçage en premier
lieu. Dévisser le bou-
chon d’amorçage et
vérifier la présence
d’eau dans le trou
d’amorçage
La pompe ne fournie
pas d’eau à pleine
capacité
1. Le sectionneur n’est pas en
marche
2. Fusible sauté
3. L’interrupteur d’allumage
est défectueux
4. Les fils au moteur sont
desserrés, débranchés ou
installés incorrectement
1. L’installation de fils du
moteur est incorrect
2. Tension trop basse
3. Station de pompage insu-
fisamment ventilée
1. La pompe dans la nouvelle
installation ne s’est pas
amorcée à cause de:
a. L’amorçage incorrect
b. Fuites d’air
c. Fuite de clapet de pied
2. La pompe a perdue son
amorçage à cause de:
a. fuites d’air
b. niveau d’eau sous le
niveau d’aspiration de la
pompe
3. Turbine obstruée
4. Vérifier si le clapet ou le
clapet de pied est pris dans
la position fermée
5. Tuyaux congelés
6. Clapet de pied et/ou tamis
sont enterrés dans le sable
ou la boue
1. Le niveau d’eau dans le
puits est plus bas qu’estimé
2. La tuyauterie en acier (si
utilisée) est rouillée ou
encrassée et cause un excès
de friction
3. La tuyauterie est trop petite
1. S’assurer que le sectionneur est en marche
2. Remplacer la fusible
3. Remplacer l’interrupteur d’allumage
4. Se référer aux instructions d’installation de fils. Vérifier et ser-
rer tous les fils
La tension du condensateur peut
être hasardeux. Pour décharger le
condensateur, toucher les bornes courts du condensateur avec
un tournevis isolant. S’ASSURER de tenir la manche du tournevis
pendant le contact aux bornes du condensateur.
1. Se référer aux instructions d’installation de fils
2. Consulter la compagnie d’électricité. Installer des fils plus
lourd si la taille de fil est trop petitie (Voir Tableau
d’Installation de Fils)
3. S’assurer que la pompe soit suffisamment ventilée pour
refroidir le moteur
1. Installation nouvelle:
a. Amorcer à nouveau selon les instructions
b. Vérifier tous les raccordements sur la ligne d’aspiration
c. Remplacer le clapet de pied
2. Installations en existance:
a. Vérifier tous les branchements sur la ligne d’aspiration et
du joint d’arbre
b. Baisser la ligne d’aspiration dans l’eau et amorcer à nou-
veau. Si l’eau dans le puits diminue et dépasse la hauteur
d’aspiration, une pompe de puits profond est exigé
3. Nettoyer la turbine
4. Remplacer le clapet ou le clapet de pied
5. Dégeler les tuyaux. Enterrer les tuyaux sous le niveau de la
gelée. Faire chauffer la fosse ou la cabanne de pompe
6. Soulever le clapet de pied et/ou le tamis au dessus du fond du
puits
1. Une pompe à jet pour puits profond peut être nécessaire (plus
que 7,6 mètres à l’eau)
2. Remplacer avec la tuyauterie en plastique là où possible ou
avec la tuyauterie nouvelle en acier
3. Utiliser la tuyauterie plus large
!
AVERTISSEMENT
Instructions d’Utilisation et Manuel de Pièces de Rechange
Série WLS
13 Fr
Notes
Notas
Operating Instructions and Parts Manual
Instructions d’Utilisation et Manuel de Pièces de Rechange
Manual de Instrucciones y Lista de Repuestos
WLS Series
Série WLS
Serie WLS
8

Instructions d’Utilisation et Manuel de Pièces de Rechange
Pompe Pour Arrosoir De Pelouse
12 Fr
Fonctionnement (Suite)
Si la pompe ne fonctionne pas après
plusieurs essais, vérifier que:
1. La distance verticale de la pompe au
niveau d’eau ne doit pas dépasser
7,6 mètres.
2. La tuyauterie d’aspiration doit être
étanche.
3. S’assurer que la(les) soupape(s)
soient ouverte(s) si utilisée(s) dans la
tuyauterie de décharge ou d’aspira-
tion.
Ne
jamais
faire fonctionner la pompe si le
décharge est fermé ou obstrué. L’eau
dans la pompe peut bouillir et endom-
mager la pompe.
Entretien
Conserver la ventilation suffisante pour
le moteur de la pompe. Les roulements
du moteur sont graissés en permanance
à l’usine. Aucun graissage additionnel
est exigé.
!
ATTENTION
PURGER POUR L’HIVER
Toujours protéger la pompe et la
tuyauterie contre la congélation. S’il y a
danger de congélation, purger le sys-
tème:
1. Enlever le bouchon mâle de tuyau
du té de décharge.
2. Enlever le bouchon d’6,4 mm du bas
de la face supérieure de la pompe.
3. Purger toute la tuyauterie située
sous le niveau de gelée.
1,5 14,761 12,566 8,781
3 14,308 11,810 7,949
4,6 13,627 11,015 4,504
6,1 12,302 10,107 3,747
7,6 11,394 9,690 3,179
Capacité de Pompe 3/4 HP en litres/heure
Hauteur Pression de Service (kPa)
en mètres 69 138 207
1,5 16,693 14,838 9,728
3 15,823 13,324 8,706
4,6 14,498 12,643 6,738
6,1 13,930 11,583 4,391
7,6 12,643 10,296 4,769
Capacité de Pompe 1 HP en litres/min
Hauteur Pression de Service (kPa)
en mètres 69 138 207
1,5 18,132 16,958 13,173 7,797
3 17,450 16,315 12,075 5,753
4,6 16,352 15,293 10,977 0
6,1 14,763 14,081 10,144 0
7,6 14,422 12,491 9,047 0
Capacité de Pompe 1-1/2 HP en litres/min
Hauteur Pression de Service (kPa)
en mètres 69 138 207 276
1,5 22,636 21,046 16,315 11,583
3 20,479 19,759 15,482 10,901
4,6 19,797 18,851 14,763 9,728
6,1 15,595 14,535 13,286 8,365
7,6 15,065 13,627 12,491 0
Capacité de Pompe 2 HP en litres/min
Hauteur Pression de Service (kPa)
en mètres 69 138 207 276
1-1/4 po 17,9 26,9 37,9 64,8 97,2
1-1/2 po 8,3 17,9 30,3 46,2 64,8 109,6
2 po 4,1 5,5 8,9 13,8 19,3 32,4 48,9 68,9
2-1/2 po 4,1 5,5 8,3 8,9 20,7 28,9
* Multiplier par 1,8 pour les tuyaux en acier
Perte de Friction kPa dans 30,5 mètres de Tuyauterie en Plastique*
Taille de (litres par Heure)
Tuyau 4,542 5,678 6,814 9,085 11,356 13,627 18,170 22,712 27,255
Pompe Pour
Arrosoir De
Pelouse
S’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser ou de procéder à l’entretien du produit
décrit. Se protéger ainsi que les autres en observant toutes les instructions de sécurité, sinon, il y a risque de blessure et/ou dégâts matériels!
Conserver ces instructions comme référence.
© 1998 Wayne Home Equipment
Description
Cette pompe centrifuge de haute
capacité à auto-amorçage est conven-
able pour l’arrosage de pelouses ou
autres applications là où de larges
quantités d’eau soient exigées. Ne
jamais utiliser des liquides inflamma-
bles tels que l’essence, des produits
chimiques ni de liquides corrosifs avec
cette pompe.
Directives De Sécurité
Ce manuel contient de l’information très
importante qui est fournie pour la
SÉCURITÉ et pour ÉVITER LES PROBLÈMES
D’ÉQUIPEMENT. Rechercher les symboles
suivants pour cette information.
Danger
indique
une situation hasardeuse imminente
qui résultera en perte de vie ou
blessures graves.
Avertis-
sement
indique une situation hasardeuse
potentielle qui peut résulter en perte
de vie ou blessures graves.
Attention
indique
unesituation hasardeuse potentielle
qui peut résulter en blessures.
Avis
indique
l’information importante pour éviter le
dommage de l’équipement.
Généralités Sur La Sécurité
1. Lire ces directives et ces
instructions attentive-
ment. Manque de suivre
ces instructions peut
causer de blessures
graves et/ou dégâts matériaux.
Cette
pompe
n’est pas submersible.
!
DANGER
AVIS
!
ATTENTION
!
AVERTISSEMENT
!
DANGER
Instructions d’Utilisation et Manuel de Pièces de Rechange Série WLS
Ne pas pomper les fluides
explosifs tels que l’essence,
l’huile à chauffage, le
kérosène etc. Ne pas utiliser dans un
atmosphère inflammable et/ou
explosif. La pompe devrait être utilisée
pour le pompage de l’eau claire seule-
ment, sinon, il y a risque de blessures
personnelles et/ou dégâts matériels.
Cette
pompe
n’est pas conçue pour les substances
qui contiennent les produits chimiques
caustiques et/ou les matières
étrangères tels que l’eau salée, la
saumure, le décharge de buanderie.
L’utilisation de ces produits peut
endommager la pompe et annulera la
garantie.
Toute installation de fils doit
être effectuée par un élec-
tricien qualifié. La pompe
doit être installée conformément aux
codes locaux et nationaux.
2. Brancher ce produit à un circuit mis
à la terre équipé d’un appareil
DDFT.
3. Avant l’installation de ce produit,
faire inspecter le circuit électrique
par un électricien afin d’assurer la
mise à la terre correcte.
4. S’ASSURER que la source
de puissance de la pompe
soit débranchée avant
d’installer ou de procéder
à l’entretien de la pompe.
5. Vérifier le réglage de tension de
moteur sur la plaque d’extrémité du
moteur et s’assurer que la tension
de la ligne du courant électrique
soit correcte.
6. S’assurer que la source d’eau et la
tuyauterie soit libre de sable, saleté
!
AVERTISSEMENT
AVIS
!
AVERTISSEMENT
320200-001 6/98
et de dépôts. Le débris peut
obstruer la pompe et annuler la
garantie.
7. Manque de protéger la pompe et la
tuyauterie contre la congélation
l’endommagera et annulera la
garantie.
8. Ne pas faire fonctionner la pompe
sèche. Suivre les instructions
d’amorçage.
Installation
Protéger la pompe contre les éléments
en installant la pompe dans un sous-sol,
garage, cabane à outils ou à pompe.
Installer la pompe avec la ligne centrale
aussi près que possible au niveau d’eau.
Garder l’endroit d’installation sans
obstructions afin de fournir l’accès à la
pompe pour le service et l’entretien.
Protéger la pompe contre l’inondation
et l’humidité excessive.
Assurer la ventilation suffisante de la
pompe. Pour éviter le déclenchement du
moteur, la température des alentours ne
devrait pas dépasser 38
o
C (100
o
F).
INSTALLATION DE LA TUYAUTERIE
Pour un meilleur résultat, utiliser des
nouveaux tuyaux galvanisés ou en plas-
tique. Si vous utilisez un tuyau gal-
vanisé, il est nécessaire de fournir des
supports indépendents pour les tuyaux
d’aspiration et de décharge près de la
pompe afin d’éviter de forcer la
pompe. Minimiser l’utilisation de
coudes et de raccords pour réduire la
perte de friction. Se référer au tableau
de perte de friction pour plus d’infor-
mation.
Augmenter le diamètre de la tuyauterie
d’aspiration ou décharge si la longueur
est plus que 15,24 mètres.
9Fr

Le moteur doit être mis à la terre en
branchant un fil conducteur en cuivre à
la vis mise à la terre fournie à l’in-
térieur de la boîte d’installation de fils.
La tension de la source d’alimentation
doit correspondre avec la tension de la
pompe. Le WLS75, WLS100 et WLS150
ont des moteurs à double tension réglés
d’avance à l’usine à 230 volts. Les mod-
èles peuvent être transformés à 115
volts en tournant le sélecteur de tension
à la tension désirée (Voir la Figure 5).
Utiliser des pinces à long bec et tirer le
sélecteur environ 6,4 mm, tourner, et le
fixer dans la position correcte. Le
WLS200 ne peut pas être transformé,
le moteur est seulement 230 volts.
Fonctionnement
Ne
jamais
faire fonctionner la pompe sèche. Le
fonctionnement de la pompe sans eau
peut causer du dommage aux joints.
Remplir la pompe avec de l’eau avant
le démarrage.
AMORÇAGE DE LA POMPE
Une fois que l’installation soit com-
plète, la pompe doit être amorcée.
Enlever le bouchon mâle de tuyau dans
la tuyauterie de décharge et remplir la
pompe et le tuyau d’aspiration avec de
l’eau propre. Mettre la pompe en
marche. Si la pompe ne pompe pas
d’eau dans 10 minutes, couper la
pompe et remplir à nouveau avec de
l’eau propre.
!
ATTENTION
11 Fr
Instructions d’Utilisation et Manuel de Pièces de Rechange
Installation (Suite)
En option, un clapet en canalisation
peut être utilisé avec un puits fiché (Voir
Figure 4).
Il peut être nécessaire de fournir la
pompe avec des pointes de pénétration
multiples afin de soutenir le haut débit
de cette pompe. Consulter un plombier
professionnel pour les matériaux et les
instructions de montage convenables.
Les fuites dans les joints ou les accouple-
ments permetteront que l’air entre le
tuyau ce qui peut causer le pauvre ren-
dement de la pompe. Utiliser du mastic
pour joints ou du ruban Teflon
®
sur tous
les raccords.
Installation Pour Puits
Creusés, Réservoirs, Lacs Et
Sources
1. Installer un clapet de pied sur le
tuyau d’admission et le baisser dans
l’eau.
Situer le
clapet de
pied au moins 2 pieds du fond de la
source d’eau afin que la sable ou le sédi-
ment ne soient pas tirés dans le système.
REMARQUE: Lorsque la source d’eau
utilisée est un lac, s’assurer que le tuyau
d’aspiration soit assez creux et toujours
submergé. Incliner le tuyau en haut vers
la pompe afin d’éliminer l’aspiration
d’air. Le tuyau doit être enlevé pendant
les mois d’hiver ou protégé contre la
congélation.
!
ATTENTION
Protéger
le tuyau
contre le dommage des nageurs et des
bateaux.
Raccordements Électriques
Brancher la pompe à un circuit élec-
trique séparé ayant un disjoncteur
unique. Se référer aux spécifications
électriques sur le tableau d’installation
de fils pour le disjoncteur et tailles de
fils recommandés.
L’installation et l’entretien des fils pour
cette pompe doivent conformer au
code National (National Electrical code)
et tous codes électriques locaux.
!
AVERTISSEMENT
Série WLS
115 V
230 V
115 V
230 V
Figure 5 - Sélecteur de Tension
WLS75 3/4 115 13.5 20 12 12 10 10
230 7.0 15 14 14 12 12
WLS100 1 115 14.8 20 12 12 10 10
230 7.4 15 14 14 12 12
WLS150 1-1/2 115 17.0 30 10 10 8 8
230 8.5 15 14 14 12 12
WLS200 2 230 12.0 15 14 14 12 12
Distance en Mètres du Moteur à la Source
Ampères Ampères 0 15,5 30,8 61,3
De Charge De 15,2 30,5 61 91,4
Modèle HP Volts Max. Fusibles (Taille de Fil AWG)
TABLEAU D’INSTALLATION DE FILS - TAILLES DE FILS ET FUSIBLES
10 Fr
Instructions d’Utilisation et Manuel de Pièces de Rechange
Installation (Suite)
TUYAUTERIE D’ASPIRATION
Installer
un clapet
de pied ou un tamis de filtre sur l’ar-
rivée de la tuyauterie d’aspiration.
Ne jamais utiliser un tuyau de diamètre
plus petit que 5,1 cm pour tuyauterie
d’aspiration. Le tuyau d’aspiration doit
être libre de fuites.
Pour les courses horizontaux, placer le
tuyau de la source d’eau afin que la
pente ascendante soit au moins 12,7 cm
par mètres. Ceci sert à éliminer la col-
lection d’air. L’arrivée filetée de la
pompe est 5,1 cm NPT.
Ne pas
installer
la tuyauterie d’aspiration à proximité
des endroits de natation.
TUYAUTERIE DE DÉCHARGE
Installer un té de tuyau d’3,81 cm dans le
décharge de la pompe afin de permettre
l’amorçage facile. Boucher le bout du té
situé au sens opposé de la pompe afin
de permettre que la tuyauterie de
branchement soit dirigé vers les buses de
pulvérisation (Voir Figure 1). Enlever le
bouchon mâle de tuyau afin de remplir
la pompe d’eau pour l’amorçage.
BRANCHEMENT À LA SOURCE D’EAU
La hauteur d’aspiration verticale
maximum de la pompe au niveau d’eau
est de 7,62 mètres.
!
DANGER
!
AVERTISSEMENT
PUITS FORÉ
1. Installer un clapet de pied sur la pre-
mière section de tuyau (voir Figure 2).
2. Faire baisser le tuyau dans le puits.
3. Ajouter de la tuyauterie jusqu’à ce
que le clapet de pied soit 3 mètres
sous le niveau d’eau le plus bas prévu.
Des fuites aux joints ou aux accouple-
ments permettront que l’air entre le
tuyau et peuvent causer le mauvais fonc-
tionnement de la pompe. S’assurer d’u-
tiliser du mastic pour joints ou du ruban
Teflon
®
sur tous les raccordements.
Situer le
clapet de
pied plus que 0,61 mètres du fond du
puits afin d’empêcher l’aspiration de
sable ou de sédiment.
4. Une fois que la profondeur correcte
soit atteinte, installer un joint de
puits ou un adaptateur pour
soutenir le tuyau.
5. Incliner le tuyau horizontal en haut
vers la pompe afin d’éliminer la col-
lecton d’air.
6. Si un clapet de pied est utilisé, l’util-
isation d’un té d’amorçage et d’un
bouchon mâle en haut du joint de
puits est recommandé.
!
ATTENTION
PUITS FICHÉ
1. Ficher le point plusieurs pieds sous
le niveau hydrostatique.
REMARQUE: Un clapet de pied à garni-
ture peut être installé dans le puits
(Voir Figure 3). Ce type de clapet de
pied permet que le tuyau de puits se
remplisse d’eau pendant l’amorçage et
permet l’inspection facile du tuyau d’ar-
rivée pour des fuites. Suivre les instruc-
tions du fabricant pour l’installation du
clapet de pied à garniture.
Pompe Pour Arrosoir De Pelouse
À La Pompe
Joint De Puits
Coffrage
De Puits
Clapet De
Pied
Figure 2
Tuyau De
Pénétration
Figure 3
À La Pompe
Clapet De Pied
À Garniture
À La Pompe
Clapet En
Canalisation
Tuyau De
Pénétration
Figure 4
Bouchon Mâle
de Tuyau
Aux Buses de
Pulvérisation
Petit
Morceau
de Tuyau
Té de Tuyau
3,81 cm
Pompe
Figure 1