Honda EB5000 Industrial Generator

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual
  • Owner's Manual EA7 3122769 - 9999999 - (English) Read Online | Download pdf
  • Owner's Manual EAKC 1044406 - 9999999 - (English) Download
  • Owner's Manual AG, AN types (mfg on or after 4/1/23) EBPC 1519915 - 9999999 - (English) Download
  • Owner's Manual EA7 3104994 - 3122768 - (English) Download
  • Owner's Manual EA7 3100001 - 3104993 - (English) Download
  • Owner's Manual EA7 3000001 - 3099999 - (English) Download
  • Owner's Manual AG type EBPC 1506333 - 1519914 - (English) Download
  • Owner's Manual EBPC 1025411 - 1506332 - (English) Download
  • Owner's Manual EAKC 1037291 - 1044405 - (English) Download
  • Owner's Manual EAKC 1000001 - 1037290 - (English) Download
  • Owner's Manual EBPC 1000001 - 1025410 - (English) Download
Other Documents
  • AC Receptacle Selection EAKC 1000001 - 9999999 - (English) Download
  • Breather Heater Kit EAKC 1000001 - 9999999 - (English) Download
User Service
  • Common replacement parts guide EAKC 1000001 - 9999999 - (English) Download
Installation Instruction
  • Handle and Wheel Kit Installation EAKC 1000001 - 9999999 - (English) Download
EB5000 photo

Owner's Manual EA7 3122769 - 9999999

This is the main product document for model EB5000. Additionally, the document applies to other Honda models: EB5000XK3AN, EB5000XK3AG

The file format is pdf, 59 pages, you can download this manual here .

background
background
The engine exhaust from this product
contains chemicals known to the State
of California to cause cancer, birth
defects or other reproductive harm.
The generator is a potential source of electrical shock if misused. Do
not expose the generator to moisture, rain or snow. Do not let the
generator get wet, and do not operate
it
with wet hands.
Keep this owner's manual handy,
so
you can refer to
it
at
any time.
This owner's manual is considered
a
permanent part of the generator
and should remain with the generator if resold.
The information and specifications included in this publication were in
effect
at
the time of approval for printing. Honda Motor
Co.,
Ltd.
reserves the right, however, to discontinue or change specifications or
design
at
any time without notice and without incurring any obIi,gation
whatever.
No
part of this publication may be reproduced without
written permission.
background
Congratulations on your selection of
a
Honda generator. We are
certain you
will
be pleased with your purchase of one of the finest
generators on the market.
We want to help you get the best results from your new generator and
to operate
it
safely. This manual contains the information on how to
do that; please read
it
carefully.
As
you read this manual, you will find information preceded
by
a
r-
symbol. That information is intended to help you avoid
damage to your generator, other property, or the environment.
We suggest you read the warranty policy to fully understand its
coverage and your responsibilities of ownership. Thewarranty policy
is
a
separate document that should have been given to you by your
dealer.
When your generator needs scheduled maintenance, keep in mind
that your Honda servicing dealer is specially trained in servicing
Honda generators. Your authorized Honda servicing dealer is
dedicated to your satisfaction and
will
be pleased to answer your
questions and concerns.
Best Wishes,
Honda Motor
Co.,
Ltd.
1
background
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important. And using
this generator safely
is
an important responsibility.
To help you make informed decisions about safety, we have provided
operating procedures and other information on labels and in this
manual. This information alerts you to potential hazards that could
hurt you or others.
Of
course,
it
is not practical or possible to warn you about
all
the
hazards associated with operating or maintaining
a
generator. You
must use your own good judgment.
You
will
find important safety information in
a
variety of forms,
including:
Safety
Labels
-
on the generator.
Safety Messages
-
preceded by
a
safety alert symbol
A
and one
of three signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
You WILL be KILLED or SERIOUSLY
HURT
if
you don’t follow instructions.
You CAN be KILLED or SERIOUSLY HURT if
you don’t follow instructions.
You CAN be HURT if you don‘t follow instruc-
tions.
Safety Headings
-
such as
IMPORTANT SAFETY
INFORMATION.
Safety Section
-
such
as
GENERATOR SAFETY
Instructions
-
how to use this generator correctly and safely.
This entire book is filled with important safety information
-
please
I
read
it
carefully.
2
background
CONTENTS
SAFETY
.......................................................................................................
5
Safety Label Locations
........................................................................
5
Safety Information
...............................................................................
7
COMPONENT IDENTIFICATION
...............................................................
9
CONTROLS
...............................................................................................
11
Engine Switch
.....................................................................................
11
Recoil Starter
......................................................................................
11
Fuel Valve Lever
.................................................................................
12
Choke Rod
...........................................................................................
12
Voltage Selector Switch (Dual Voltage System)
.............................
13
Ground Terminal
................................................................................
13
Oil Alert@ System
...............................................................................
14
Auto-throttle System
.........................................................................
14
Circuit
Breaker
....................................................................................
15
Circuit Protector
.................................................................................
16
Ground Fault Circuit Interrupter (GFCI)
............................................
17
GENERATOR
USE
....................................................................................
21
Connections to a Building's Electrical System
................................
21
Ground System
...................................................................................
21
Special Requirements
........................................................................
21
AC Operation
......................................................................................
23
AC Receptacle Selection
.................................................................... 24
Auto-throttle System
.........................................................................
25
High Altitude Operation
.....................................................................
26
Engine Oil
...........................................................................................
27
Fuel
......................................................................................................
28
STARTING THE ENGINE/STOPPING THE ENGINE
...............................
30
MAINTENANCE
.......................................................................................
31
The Importance of Maintenance
.......................................................
31
Maintenance Safety
...........................................................................
32
Emission Control System Information
.............................................
33
Air Index
..............................................................................................
36
Maintenance Schedule
......................................................................
37
Engine Oil Change
.............................................................................
38
Air Cleaner Service
............................................................................
39
Fuel Sediment Cup Cleaning
............................................................
40
Spark Plug Service
.............................................................................
41
Spark Arrester Maintenance
.............................................................
42
AC Applications
..................................................................................
22
PRE-OPERATION CHECK
........................................................................
27
background
Pni
+:
04:
2,:
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
background
SAFETY
SAFETY LABEL LOCATION
These labels warn you
of
potential hazards that can cause serious
injury. Read them carefully.
If
a
label comes off or becomes hard to read, contact your Honda
generator dealer for
a
replacement.
5
background
A
WARNING
You
risk electric shock
if
you
operate
this generator with a faulty
GFCl
(ground-fault circuit-interrupter).
Test
GFCl
before each use.
If
GFCl
fails test,
do
not use
your
generator. See your Honda dealer.
I
EB5000X
HONDA
MOTOR
CO.,
LTD.
MADEIN
JAPAN
Q
WITH RECOMMENDED
OIL
FREQUENCY
1201240V
BEFORE USING. RATED OUTPUT 4.5kVA
SEE THE OWNER’S MANUAL. PHASE
6
background
SAFETY INFORMATION
Honda generators are designed to give safe and dependable service
if
operated according to instructions. Read and understand this owner's
manual before operating your generator.
You
can help prevent
accidents
by
being familiar
with
your generator's controls, and
by
observing safe operating procedures.
Operator Responsibility
Know how to stop the generator quickly
in
case of emergency.
Understand the use of all generator controls, output receptacles,
and connectiom--
Be sure that anyone who operates the generator receives proper
instruction.
Do
not let children operate the generator without
parental supervision.
Carbon Monoxide
Hazards
*
Exhaust contains poisonous carbon monoxide, a colorless and
odorless gas. Breathing exhaust can cause
loss
of consciousness
and may lead to death.
If
you run the generator
in
an area that
is
confined, or even partially
enclosed, the air you breathe could contain a dangerous amount
of
exhaust gas.
To
keep exhaust gas from accumulating, provide
adequate ventilation.
7
background
Electric
Shock Hazards
The generator produces enough electric power to cause a serious
shock or electrocution if misused.
Using a generator or electrical appliance in wet conditions, such as
rain or snow, or near a pool or sprinkler system, or when your hands
are wet, could result
in
electrocution. Keep the generator dry.
If
the generator is stored outdoors, unprotected from the weather,
check the Ground-Fault Circuit Interrupter (GFCI), and all other
electrical components on the control panel, before each use.
Moisture or ice can cause a malfunction or short circuit
in
electrical
components which could result in electrocution.
e
Do
not connect to a building electrical system unless an isolation
switch has been installed by a qualified electrician.
e
Do
not connect
to
swimming pool equipment installed before
adoption ofthe
1965
national electric code.
Fire
and Burn Hazards
The exhaust system gets hot enough to ignite some materials.
-Keep the generator at least
3
feet
(1
meter
)
away from buildings
-Do
not enclose the generator
in
any structure.
-Keep flammable materials away from the generator.
and other equipment during operation.
The muffler becomes very hot during operation and remains hot for
a while after stopping the engine. Be careful not to touch the muffler
while
it
is
hot. Let the engine cool before storing the generator
indoors.
Gasoline is extremely flammable and is explosive under certain
conditions.
Do
not smoke or allow flames or sparks where the
generator is refueled or where gasoline is stored. Refuel
in
a well-
ventilated area
with
the engine stopped.
Fuel vapors are extremely flammable and may ignite after the
engine has started. Make sure that any spilled fuel has been wiped
up
before starting the generator.
background
COMPONENT IDENTIFICATION
VOLTAGE SELECTOR SWITCH
GFCl RESET BUTTON
and
GFCl
TEST BUTTON
AC CIRCUIT BREAKER
CHOKE
ROD
AC CIRCUIT
PROTECTORS
AIR CLEANER
RECEPTACLES
ENGINE OIL FILLER
CAP
RECOIL STARTER GRIP
ENGINE
SERIAL
NUMBER
9
background
FUEL
FILLER
CAP
\
\
i
FUEL
GAUGE
\
SPARK
PLUG
CAP
/
FRAME
SERIAL
NUMBER
MUFFLER
*Record the engine and frame serial numbers for your future
reference. Refer to these serial numbers when ordering parts, and
when making technical
or
warranty inquiries (see page52
).
Frame serial number:
Engine serial number:
10
background
CONTROLS
ENGINE
SWITCH
To
start and stop the engine.
Switch position:
OFF:
To
stop the engine.
ON: To
start and run the engine.
ENGINE
SWITCH
OFF
RECOIL STARTER
To
start
the engine,
pull
,the
starter
grip
lightly until resistance is felt,
then
pull
briskly.
pKF
Do
not allow the starter grip
to
snap back against the engine. Return
it
gently to prevent damage
to
the starter.
STARTER
GRIP
background
VOLTAGE SELECTOR SWITCH (DUAL VOLTAGE SYSTEM)
The voltage selector switches the main power carrying windings
of
the
generator to produce
"120V
ONLY" or
"120/240V".
If
a
240V
appliance
is connected to the 4-prong receptacle, the switch must be
in
the
"1201
240V"
position.
If
only
a
120V
appliance is being connected to any of
the
120V
3-prong receptacles, select the
"1 20V
ONLY" position.
120/240V:
The
120V
and
120/240V
receptacles can be used
simultaneously.
120V ONLY:
ONLY the
120V
receptacles can be used.
Do
not use the
120/240V
receptacle
in
this position. Rated power will
be available at the
30A
120V
locking plug receptacle.
"120V ONLY"
/-
VOLTAGE SELECTOR
SWITCH
-";i".i
0
Q
Q
8
GROUND TERMINAL
The generator ground terminal is connected to the frame of the
generator, the metal non-current-carrying parts of the generator, and
the ground terminals of each receptacle.
Before using the ground terminal, consult a qualified electrician,
electrical inspector or local agency having jurisdiction for local codes
or ordinances that apply to the intended use of the generator.
background
OIL ALERT@ SYSTEM
The Oil Alert@ system is designed to prevent engine damage caused
by
an insufficient amount of oil
in
the crankcase. Before the oil level
in
the crankcase can fall below a safe
limit,
the Oil Alert@ system will
automatically stop the engine (the engine switch
will
remain
in
the
ON
position).
If the engine stops and will not restart, check the engine
oil
level (see
page
27
)
before troubleshooting
in
other areas.
OIL FILLER HOLE
UPPE
LEV€
Qlk
FILLER
Auto-throttle System
The auto-throttle system automatically reduces engine speed when all
loads are turned off or disconnected. When appliances are turned on
or reconnected, the engine returns to the rated speed.
AUTO:
Recommended to minimize fuel consumption and further
OFF:
The auto-throttle system does not operate.
reduce noise levels when no load is applied to the generator.
Recommended to minimize warm-up time when the
generator is started.
AUTO-THROTTLE
SWITCH
14
background
CIRCUIT
BREAKER
The circuit breaker will automatically switch
OFF
if
there is a short
circuit or a significant overload of the generator at the receptacle, or
if
the ground-fault circuit interrupter
(GFCI)
detects
a
ground-fault
current.
Check the following if the circuit breaker switches
OFF
automatically:
When
.the
GFCl
RESET button
is
extended (page
19
):
-Unplug
all
appliances
from
the receptacle and check the appliance
for
any defects as described
in
TROUBLESHOOTING
(page
46
)~
After making repairs, push the
GFCl
RESET button then turn the
circuit breaker
ON.
~ ~~ ~~
a
When
the
GFCl
RESET
but hot-^
is
not
extended:
-Check that the appliance
is
working
properly and does not exceed
the
rated load capacity of the circuit before switching the circuit
breaker
ON
again.
The
ci~~e~lit
breaker
may
be
used
.to
switch
the
generator
power
on
or
off.
15
background
CIRCUIT PROTECTOR
The circuit protectors will automatically switch
OFF
if
there is
a
short
circuit or a significant overload of the generator
at
the 20A 120V, 30A
120V locking plug, or 120/240V locking plug receptacle.
If
a
circuit
protector is switches
OFF
automatically, check that the appliance is
working properly and does not exceed the rated load capacity
of
the
circuit before resetting the circuit protector
ON.
ON
OFF
16
background
Observe the following precautions to ensure proper GFCl operation
and to reduce shock hazards:
Use grounded 3-conductor extension cords, tools, and appliances,
or double-insulated tools and appliances.
Inspect cords and plugs, and replace if damaged.
Do
not use cord lengths greater than
164
feet
(50
meters), and
do
not use multiple tools and appliances with built-in noise filters. Such
use may activate the GFCl and trip the circuit breaker.
18
background
Inspection:
Always check GFCl operation before using the generator.
You
risk electric shock if
you
operate this generator with a faulty GFCI
(ground-fault circuit interrupter).
Test GFCl before use.
If
GFCl fails test, do not use your generator. See your Honda dealer.
1.
Unplug
all
look
and
appliances
from
the generator.
2.
Start the engine.
3.
Turn the circuit breaker to
the
ON
position.
4.
Turn the autothrottole switch to the OFF position.
5.
Press the GFCl TEST button. The
RESET
button should extend, and
the
circuit breaker should switch to the OFF position.
If
the
GFCl
and circuit breaker
do
not
function
as
described, take
the
generator to an authorized Honda generator dealer for repair.
GFCI
RESET
BUTTON
GFCl
TEST
BUTTON
CIRCUIT
BREAKER
19
background
background
GENERATOR
USE
CONNECTIONS TO
A
BUILDING ELECTRICAL
SYSTEM
Connections for standby power to a building electrical system must be
made
by
a qualified electrician. The connection must isolate the
generator power from utility power, and must comply
with
all
applicable laws and electrical codes. A transfer switch, which isolates
generator power from utility power, is available through authorized
Honda generator dealers.
Improper connections
to
a building electrical system can allow
electricai current from the generator to backfeed
into
the
utility
lines.
Such backfeed may electrocute
utility
company workers
or
others
who contact the lines during a power outage, and the generator may
explode,
burn,
or
cause fires when
utility
power is restored. Consult
the
utility
company
or
a
qualified electrician.
~ ~
~~~___~~~
GROUND
SYSTEM
Honda portable generators have
a
system ground that connects
generator frame components
to
the
ground .terminals
in
the AC output
receptacles. The system ground
is
not connected to
.the
AC
neutral
wire.
If
the
generator
is
tested
by
a
receptacle tester,
it
will
not
show
the
same ground
circuit
condition
as
for
.a
home
receptacle.
SPECiAL
REQUIREMENTS
There may
be
Federal or State Occupational Safety and Health
Administration (OSHA) regulations, local codes,
or
ordinances that
apply to the intended use
of
the generator. Please consult a qualified
electrician, electrical inspector, or the local agency having jurisdiction.
In
some areas, generators are required to be registered
with
local
utility companies.
*
If
the generator is used at a construction site, there
may
be
additional regulations which must be observed.
21
background
AC APPLICATIONS
Before connecting
an
appliance or power cord to the generator:
Make sure that
it
is
in
good working order. Faulty appliances or
power cords can create a potential for electrical shock.
If
an appliance begins to operate abnormally, becomes sluggish or
stops suddenly, turn
it
off immediately. Disconnect the appliance,
and determine whether the problem is the appliance, or
if
the rated
load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not
exceed that
of
the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than
30
minutes.
I
NOTICE
1
Substantial overloading
will
open the circuit breaker. Exceeding the
time limit for maximum power operation or slightly overloading the
generator may not switch the circuit breaker
OFF,
but will shorten the
service life of the generator.
Limit operation requiring maximum power to
30
minutes.
Maximum power is:
5.0
kVA
For continuous operation, do not exceed the rated power.
Rated power is:
4.5
kVA
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
22
background
A6
OPERATION
1.
Check
GFCl
operation before each use (see page
19
1.
2. Start the engine (see page30
).
3. Burn the voltage selector switch to either position.
With
the voltage selector switch
in
the
"I
20/240V" position, you can
use the 120V and 120/240V receptacles simultaneously.
If
you are
NOT
using the 120/240V receptacle, but require more power from
the 120V locking plug receptacle, then select the "120V
ONLY"
position.
4.
Make
sure
that the
GFCl
RESET
button is pushed
in
(flush with its
base plate).
5.
Switch
ON
the
AC
circuit breaker.
6.
Plug
in
the appliance.
Most
motorized appliances require
more
than
their rated wattage for
startup.
GFCB
RESET
BUTTON
VOLTAGE
SELECTOR
SWITCH
/
AC
ClRCUlT BREAKER
Do
not exceed the current
limit
specified for
any
one receptacle.
If
an
overloaded circuit causes the
AC
circuit breaker or circuit protector to
switch
OFF,
reduce the electrical load on the circuit, wait a few minutes
and then reset the circuit breaker.
23
background
AC RECEPTACLE SELECTION
The generator has separate main power producing circuits. These
:wo circuits supply equal power to different receptacles shown
Nhen the voltage selector switch
is
in the 120/240V position.
Nhen
two
or more receptacles are used; prevent overloading by
jividing the load between the two power circuits.
The chart below shows the rated load in amperes that can be
:onnected to each receptacle to balance the generator.
The total rated ampere draw is 37.5A.
Main power circuit Receptacles powered
Power distribution
by each main circuit
Main Circuit
I
j
2,3 and 4
1
2+3+4=18.8A rated.
Main Circuit
la
I
1 and
5
1
1
+
5=18.8A rated.
“The table shows
the
specifications when the 120/240V locking
plug receptacle is used for 120V.
!xample:
3eceptacle
2
has a 10A load connected to
it.
Receptacle 3 has
a
15
4
load connected to
it.
Both receptacles are powered by main
3ower circuit
It.
The equation tells us that the total power draw on
:ircuit
II
is 25A. This is
a
substantial overload
of
.this circuit. To
zliminate the excess power draw on circuit
II,
the load from
receptacle
3
should be switched to receptacle 1. Now circuit
I
is
3owering the 10A load (less than 18.8A) and circuit
II is
powering
3
15A load (less than 18.8A).
0
120v
20A
@a@
1201240V 30A
background
Auto-throttle System
With the switch in the AUTO position, engine speed is automatically
reduced when ALL loads are turned
OFF
or disconnected. When
appliances are turned
ON
or reconnected, the engine returns to rated
speed. In
the
OFF
position, the auto-throttle system does not operate.
The auto-throttle system will not respond to electrical loads
of
less
than
1
ampere. Turn the auto-throttle to the
OFF
position to operate
loads
of
less than
1
amp.
Appliances with large start-up power demands
may
not allow the
engine 'to reach normal operating rpm when they are connected to the
generator. Turn the auto-throttle to the
OFF
position and connect the
appliance 'to .the generator.
If
.the engine still will not reach normal
operating speed, check that the appliance does not exceed the rated
load capacity
of
the generator.
To
avoid extended warm-up periods, keep .the switch
OFF
until
the
engine reaches operating temperature.
The auto-throttle system is not effective
for
use with appliances that
require
only
momentary power.
If
,the tool or appliance will be turned
ON
and
OFF
quickly,
.the
auto-thrsi"rle
switch should be
in
the
OFF
position.
25
background
HIGH
ALTITUDE
OPERATION
At high altitude, the standard carburetor air-fuel mixture
will
be too
rich. Performance will decrease, and fuel consumption will increase. A
very rich mixture will also foul the spark plug and cause hard starting.
High altitude performance can be improved by specific modifications
to the carburetor. If you always operate your generator
at
altitudes
above 1,500 meters (5,000 feet), have your dealer perform this
carburetor modification.
Even
with
carburetor modification, engine horsepower will decrease
about 3.5% for each 300-meter (1,000-foot) increase
in
altitude. The ef-
fect of altitude on horsepower will be greater than this
if
no carburetor
modification is made.
When the carburetor has been modified for
high
altitude operation,
the air-fuel mixture
will
be too lean for low altitude use. Operation at
altitudes
below
1,500
meters
(5,000
feet)
with
a modified carburetor
may cause the engine to overheat and result
in
serious engine
damage. For use at low altitudes, have your dealer return the
carburetor to original factory specifications.
background
PRE-OPERATION CHECK
ENGINE
OIL
piq
Engine
oil
is a major factor affecting engine performance and service
life. Non detergent and 2-stroke engine
oils
will damage the engine
and are not recommended.
Check the oil level BEFORE
EACH USE
with
the generator on
a level surface and the engine
stopped.
Use 4-stroke motor oil
that
meets or exceeds the require-
ments for
API
service classifi-
cation
SJ.
Always
check the
API
SERVICE label on the oil contain-
er to be sure
it
includes the let-
ters
SJ.
SAE Viscosity
Grades
TEMP-20
0
20
40
60
80
100°F
1
I
I
I
I
I
I
-30
-20
-10
0
10
20
30
40°C
AMBIENT TEMPERATURE
SAE
IOW-30
is recommended
for
general, all-temperature use. Other
viscosities shown
in
the chart
may
be used when the average
temperature
in
your area is within the indicated range.
1
.Remove ,the oil filler cap and
wipe
the dipstick clean.
2.Gheck
the
oil level
bv
insertina the dipstick into the filler
neck
UPPER LEVEL
Flbl
27
background
Fuel
Check the fuel gauge, and refill the tank
if
the fuel level
is
low.
Refuel carefully to avoid spilling fuel.
Do
not fill above the shoulder of
the fuel strainer.
Gasoline
is
highly flammable and explosive, and you can be burned
or
seriously injured when refueling.
Stop engine and keep heat, sparks, and flame away.
Refuel only outdoors.
e
Wipe up spills immediately.
Fuel tank capacity:
4.49
US
gal
(17.0
a
I
3.74
Imp
gal)
FUEL
GAUGE
Use unleaded gasoline with
a
pump
octane
rating
of
86
or
higher
This
engine
is
certified to operate
on
unleaded
gasoline.
Unleaded
gasoline produces fewer engine
and
spark
plug
deposits
and
extends
exhaust system
life.
Never
use
stale
OF
contaminated
gasoliwe
or
an
oil/gaso!ine
mixture.
Avoid getting
dirt
or
water
in
the
fuel
tank.
background
Occasionally you may hear a light "spark knock" or "ping.ing"
(metallic rapping noise) while operating under heavy loads. This
IS
no
cause for concern.
If
spark knock or pinging occurs at a steady engine speed, under
normal load, change brands of gasoline.
If
spark knock or pinging
persists, see an authorized Honda generator dealer.
pEE
Running the engine with persistent spark knock
or
pinging can cause
engine damage.
Running the engine
with
persistent spark knock
or
pinging is misuse,
and
the
Distributor's Limited
Warranfydoes
not
cover parts damaged
by
misuse.
Oxygenated Fuels
Some conventional gasolines are being blended
with
alcohol
or
an
ether compound. these gasolines are collectively referred to
as
oxygenated fuels.
To
meet clean air standards, some areas of the
United
States and Canada
use
oxygenated
fuels
to help reduce
emissions.
16
you
use
an
oxygenated fuel,
be
sure
it
is unleaded and meets
the
minimum octane rating requirement.
re
using
an
oxygenated
fuel,
try
to
firm
the
fuel's contents.
e states/prsvinces require
this
infor
ion
to be posted
on
the
-
gensra'kor.
I
he
fo!lo\Ning
are
the
EPA
approved
ps
ETkiANQL
(ethyl
or
grain
alcohol)
1
You
may
use
gasoline
ng
up
lo
10%
ethanol
by
volume.
Gasoline
containing
ethanol
may
be
marE.,a.kd
under-
the
name
"Gasshoi".
Yoas
may
use
gaso0ir-E
coirsPaining
up
'20
75%
MTBE
by
You
8may
use
gasoline
containing
up
to
5%
methanol
corrosion
inhibitors
to
prolecl
.the -lase6
sys%eLmo
Gasoline
cobmining
rTore
than
5%
!-nethano8
by
problems.
It
i-nay
anso
damage
nruetao,
rubI3er,
and
plastic
parts
of
your
-fuel
system.
If
you
notice
any
undesirable
operating
sympto!-ns,
lay
another
service
station
or
switch
Yo
another
brarld
of
gasoline.
e
or
psr6ormance
probleims
rzsuleing
from
the
use
BePes
containing
more
than
the
percentages
of
sxygenstes
mentioned
above
are
not
covered
under
warranty.
MTBE
(rmethyl
tertiary
butyl
ether)
15%
by
volurne
R4ET~=U=i!WL
~
(irnetbayl
or
vuood
alcohol)
5%
by
VoBU~re
vooL!rne~
by
volume
as
long
as
it
also
contains
cosolvents
and
volume
may
causa
starting
and/or
per-brmaai-pee
29
background
STARTING THE ENGINE/SPOPPING THE ENGINE
STARTING THE ENGINE
1.
Make sure that the AC circuit breaker is
in
the
OFF
position. The
2.Turn the fuel valve lever to the ON position.
3.
Pull the choke rod to the CLOSE position.
4.
Make sure
the
auto-throttle switch is
in
the OFF position,
or
more
5.
Move the engine switch to the ON position.
6.
Pull the starter grip lightly until resistance is felt,
then
pull briskly.
generator may be hard to start if
a
load is connected.
time will be required for warm up.
I
NOTICE
I
Do
not allow the starter grip to snap back against the engine. Return
it
gently to prevent damage to the starter.
7.
Push the choke rod to the OPEN position as the engine warms up.
8.
If
you wish to use the auto-throttle system, turn the auto-throttle
switch to the
AUTO
position after the engine has warmed up fcr
2
or
3
minutes.
STOPPING
THE
ENGINE
In an emergency:
1,
To stop the engine in an emergency, move the engine switch to the
OFF position.
In normal use:
1,
Turn the AC circuit breaker to the OFF position.
2.
Move the engine switch to the OFF position.
3.
Turn the fuel valve lever to the OFF position.
30
background
MAINTENANCE
THE
IMPORTANCE
OF
MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free
operation.
It
will also help reduce air pollution.
Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction
in
which you can be seriously
hurt
or
killed.
Always follow the inspection and maintenance recommendations and
schedules
in
this owner‘s manual.
To
help you properly care for your generator, the following pages
include
a
maintenance schedule, routine inspection procedures, and
simple maintenance procedures using basic hand tools. Other service
tasks that are more difficult, or require special
tools,
are best handled
by
professionals and are normally performed by
a
Honda technician or
other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If
you operate your generator under severe conditions, such as
sustained high-load or high-temperature operation, or use
it
in
unusually wet or dusty conditions, consult your servicing dealer for
recommendations applicable to
your
individual needs and use.
Maintenance, replacement, or repair
of
the emission control devices
and systems may be performed by any engine repair establishment or
individual, using parts that are “certified” to EPA standards.
31
background
MAINTENANCE SAFETY
Some of
the
most important safety precautions follow. However,
we
cannot warn you of every conceivable hazard that can arise in
performing maintenance. Only you can decide whether or not you
should perform
a
given task.
Failure to properly
follow
maintenance instructions and precautions
can cause you to be seriously hurt or killed.
Always follow the procedures and precautions in the owner’s manual.
Safety Precautions
Make sure the engine is off before you begin
any
maintenance
or
repairs. This will eliminate several potential hazards:
-Carbon monoxide poisoning from engine exhaust.
Be sure there is adequate ventilation whenever you operate the
engine.
-Burns from hot parts.
Let the engine and exhaust system cool before touching.
-Injury from moving parts.
Do
not run
the
engine unless instructed to do
so.
Read the instructions before you begin, and make sure you have the
tools and skills required.
e
To reduce the possibility of fire or explosion, be careful
when
working around gasoline.
Use
only
a
nonflammable solvent,
not
gasoline, to clean parts. Keep cigarettes, sparks, and flames away
from
all
fuel-related parts.
Remember that your servicing dealer knows your generator best and
is fully equipped to maintain and repair
it.
To
ensure the best quality and reliability, use only new, genuine
Honda parts
or
their equivalents for repair or replacement.
background
Problems
That
May
Affect
Emissions
If you are aware of any
of
the following symptoms, have your engine
inspected and repaired by your servicing dealer.
Hard starting
or
stalling after starting.
Rough idle.
Misfiring
or
backfiring under load.
0
Afterburning (backfiring).
0
Black exhaust
smoke
or high fuel consumption.
34
background
Replacement
Parts
The emission control systems on your Honda engine were designed,
built, and certified to conform with
EPA
and California emission
regulations. We recommend the use of genuine Honda parts
whenever you have maintenance done. These original-design
replacement parts are manufactured to the same standards as the
original parts,
so
you can be confident of their performance. The use
of replacement parts that are not of the original design and quality
may impair the effectiveness of your emission control system.
A
manufacturer of an aftermarket part assumes the responsibility that
the
part will not adversely affect emission performance. The
manufacturer or rebuilder of
the
part must certify that use of the part
will
not result in
a
failure
of
the engine to comply with emission
regulations.
Maintenance
Follow the maintenance schedule on page
37
e
Remember that this
schedule is based on the assumption
that
your
machine
will
be
used
for its designed purpose. Sustained high-load or high-temperature
operation, or use in unusually wet or dusty conditions, will require
more frequent service.
background
AIR
INDEX
An Air Index Information hang tag/iabel was applied to this engine
in
accordance
with
the requirements
of
the California Air Resources
Board.
The bar graph is intended to provide you, our customer, the ability to
compare the emissions performance of available engines. The
lower
the
Air Index, the less pollution.
The durability description is intended to provide you with information
relating to the engine's emission durability period.
The
descriptive
term indicates
the
useful-life period for the engine's emission control
system. See your
Emission Control Warranty
for additional
information.
~ ~ ~ ~
Descriptive Term
50 hours (0-65 cc) Moderate
Applicable
to
Emissions Durability Period
125 hours (greater than 65 cc)
Intermediate 125 hours (0-65 cc)
250 hours (greater than 65 cc)
Extended
300
hours
(0-
65 cc)
500 hours (greater than 65 cc)
~
The Air Index information hang tag must remain
on
the generator until
it
is sold. Remove the hang tag before operating the generator.
36
background
MAINTENANCE SCHEDULE
Emission related items.
(1)
Service more frequently when used in dusty areas.
(2)
These items should be serviced by an authorized lionda generaior dealer, unless the owner
(3)
For
commercial use,
log
hours
of
operation
to
determine proper maintenance intervals.
has the proper tools
and
is mechanically proficient.
See
the
I-londa Shop Manual.
37
background
ENGINE
OIL
CHANGE
Drain the oil while the engine
is
warm to assure rapid and complete
draining.
1,
Remove the drain plug and sealing washer, remove the oil filler cap,
2.
Reinstall the drain plug and sealing washer. Tighten the plug
3.
Refill with the recommended oil (see page
27
)
and check the
oil
and drain the oil.
securely.
level.
Oil
capacity:
1.2
US
qt
(1
.I
Q,1
.O
Imp qt)
OIL
DRAIN
PLUG
Wash your hands with soap and water after handling used oil.
Please dispose of used motor oil in a manner that is compatible
with
the environment. We suggest you take
it
in
a
sealed container to your
local service station or recycling center for reclamation. Do not throw
it
in
the trash, pour
it
on
the
ground, or down
a
drain.
background
AIR CLEANER SERVICE
A
dirty air cleaner will restrict air flow to the carburetor.
To
prevent
carburetor malfunction, service the air cleaner regularly. Service more
frequently when operating the generator in extremely dusty areas.
Never run the generator without the air filter. Rapid engine wear
will
result.
1.
2.
3.
Unsnap
the
air cleaner cover clips,
remove the air cleaner cover, and
remove the
element.
Wash the air filter
in
a
solution
of
household detergent and warm
water, then rinse thoroughly,
or
wash
in
nonflammable or high
flashpoint solvent. Allow
the
air
filter to
dry
thoroughly.
Soak
the
air filter
in
clean engine
oil
and squeeze out
the
excess oil.
The
engine
will
smoke
during
initial
startup
if'too
much
oil is left
in
the
air
fiSter.
4.
Reinstall
.the
air cleaner element
and
.the
cover.
AIR CLEANER
COVER
CLIP
AIR
CLEANER ELEMENT
ELEMENT
DL
39
background
background
SPARK
PLUG SERVICE
In order to service the spark plug, you
will
need
a
spark plug wrench
(commercially available).
Recommended
spark
plugs:
BPR5ES
(NGK)
WIGEPR-U
(DENSO)
To
ensure proper engine operation, the spark plug must be properly
gapped and free of deposits.
If the engine has been running, the muffler
will
be very hot. Be careful
not to touch the muffler.
1.
Remove the spark plug cap.
2.
Clean any dirt from around the spark plug base.
3.
Use
a
spark plug wrench to remove the spark plug.
SPARK
PLUG WRENCH
4.Visually inspect .the spark plug. Discard
it
if the insulator
is
cracked
or chipped. Clean the spark plug with
a
wire brush if
it
is
to
be
reused.
Correct
as
necessary by carefully bending the side electrode.
5.
Measure
the
plug gap with
a
feeler gauge.
The
gap
should
be:
0.028-0.031
in (0.70-0.80 mm)
0.028-0.031
in
(0.70-0.80
mm)
41
background
background
background
background
TROUBLESHOOTING
When the engine will not start:
NO
Is
there fuel in the
tank?
Refill the fuel tank.
-
I
I
YES
Is
there enough oil
mended oil.
in the engine?
Add the recom-
NO
~
YES
Is
there a spark
Take the generator
plug?
Honda generator
from the
spark
to an authorized
To
check:
1)Rernove the spark
plug cap and clean
Be
sure there
is
no
any dirt from around
spilled fuel around the
the spark plug.
spark plug. Spilled
fuel
2)Remove the spark
plug and install the
spark plug in the
plug cap.
3)
Set the plug side elec-
trode on the cylinder
head.
4)Crank the engine,
sparks should jump
across the gap.
Is
the fuel reaching
sediment cup.
the carburetor?
Clean the fuel
NO
-
-
may
ignite.
I
YES
I""
If the engine still
does not start, take
the generator to
an
authorized Honda
generator dealer.
To
check:
1)Turn
off
the engine
DRAIN
SCREW
I
switch and
logsen
the drain screw.
2)Turn the fuel valve to
ON.
Fuel should flow
from the drain when
the fuel valve is
turned
ON.
r
45
background
No
electricity
at
the AC receptacles:
(When the GFCl RESET button is extended)
L
Unplug
all
appliances
(refer to page
18)
spect the GFCl operation.
is
extended
again.
and equipment, and in-
The
GFCl
RESET button
c-
Take
the
generator to
an
au-
I
thorized Honda genarator
dealer.
L
pliance or equipment.
Take the electrical ap-
pliance or equipment to
an
electrical shop for repair.
(When ,the GFCl RESET button is not extended
>
~-
Is
the
AC
circuit breaker
ON.
ON?
Turn the AC circuit breaker
Iruo-
YES
~
Is
the
AC circuit protector
ON?
Reset the circuit protector.
No-
YES
NO
DEFECTS
I
I
I
I
I
,
k-1
dealer.
1
Check the electrical
ap-
Take the generator to an au-
pliance or equipment for thorized Honda genarator
any defects.
I
DEFECTS
Replace the electrical ap-
pliance or equipment.
*Take the electrical ap-
pliance or equipment to an
electrical shop for repair.
46
background
I
EXCITER WINDING
II
ACRECEPTACLES
-
-
A-
CONTROLBOXBLOCIC
1
-c
J
OIL
LEVEL
01
background
SPECIFICATIONS
Dimensions
Model
EB5000X
Power product description code
172
Ibs
(78 kg)
Dry weight
19.3 in (490
mm)
Height
20.1
in
(510
mm)
Width
25.8
in
(655
mm)
Length
EA7
Engine
Model GX340 K1
Engine Type
Forced air
Cooling System
3,600 rpm
Engine Speed
8.0
:
1
Compression Ratio
[3.2
X
2.5
in
(82
X
64
mm)]
[Bore
X
Stroke)
20.6 cu-in (337 cm3)
Displacement
4-stroke, overhead valve, sinqle cylinder
Ignition System
BPR5ES (NGK)
Spark Plug
4.49
US
gal (17.0 Q,3.74 Imp gal)
Fuel Tank Capacity
1.2
US
qt
(1
.I
Q,1
.O
Imp
qt)
Oil
Capacity
Transistorized magneto
1
W16EPR-U (DENSO)
Generator
Model
1201240 V
-~
Rated ~ ~~~ voltage
EB5000X
TY
Pe
.~
A
Rated frequency
5.0 kVA Maximum output
4.5 kVA Rated output
60 Hz
AC output
37.511
8.8
A
Rated ampere
Tune-up Specifications
ITEM SPECIFICATION
I
MAINTENANCE
1
Spark plug gap
No other adjustments needed.
Other specifications
See your authorized
IN:
0.15
f
0.02
mm
(cold)
Valve clearance
Refer to page: 41
0.028-0.031
in
(0.70-0.80
mm)
EX:
0.20
k
0.02
mm
(cold)
Honda dealer
NOTE:
Specifications may vary according to the types, and are subject
to change without notice.
background
INSTALLATION
OF
OPTIONAL PARTS
Hanger Kit Installation
1.
Remove the upper frame. Install the hanger
on
it
and install the
upper frame on the body.
BRACKET
NOTE.
Install
at
near center avoiding the fuel filler cap.
FUEL
FILLER
CAP
/
49
background
4
Wheel
Kit Installation
1.
Install the four wheels on the axle shaft.
2.
Install the axle assembly on the generator using four bolts and nuts.
WHEEL
STOPPER
NOTE:
Install the shaft with wheel stopper facing engine side.
50
background
2
Wheel Kit Installation
1.
Install the two wheels on the axle shaft.
2.
Install the axle assembly on the generator using four bolts and nuts.
3.
Install the two stands using four bolts and nuts.
4.
Install right and left handles on the generator upper frame using
brackets and six bolts.
51
background
WARRANTY SERVICE INFORMATION
~ ~~
Servicing dealership personnel are trained professionals. They should
be able to answer any question you may have. If you encounter
a
problem that your dealer does not solve to your satisfaction, please
discuss
it
with the dealership’s management. The Service Manager or
General Manager can help. Almost all problems are solved in this way.
If
you are dissatisfied with the decision made by the dealership’s
management, contact the Honda Power Equipment Customer
Relations Office. You can write to:
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Or telephone:
(?70)
497-6400
When you write or call, please give us this information:
Model and serial number (see pages9 and
10
)
Name of dealer who sold the generator to you
Name and address of dealer who services your generator
Date of purchase
Your name, address, and telephone number
A
detailed description of the problem
52
background
INDEX
COMPONENT IDENTIFICATION
...............................................................
9
CONTENTS
.................................................................................................
3
CONTROLS
...............................................................................................
11
Choke Rod
...........................................................................................
12
Circuit Breaker
....................................................................................
15
Auto-throttle System
.........................................................................
14
Circuit Protector
.................................................................................
16
Engine Switch
.....................................................................................
11
Fuel Valve Lever
.................................................................................
12
Ground Fault Circuit Interrupter (GFCI)
............................................
17
Ground Terminal
................................................................................
13
Oil Alert@ System
...............................................................................
14
Recoil Starter
......................................................................................
11
AC Applications
..................................................................................
22
AC Operation
......................................................................................
23
AC Receptacle Selection
....................................................................
24
Connections to
a
Building's Electrical System
................................
21
Ground System
...................................................................................
21
High Altitude Operation
.....................................................................
26
Voltage Selector Switch (Dual Voltage System)
.............................
13
GENERATOR
USE
....................................................................................
21
Auto-throttle System
.........................................................................
25
Special Requirements
........................................................................
21
INSTALLATION
OF
OPTIONAL PARTS
..................................................
49
MAINTENANCE
.......................................................................................
31
Air Cleaner Service
............................................................................
39
Air Index
..............................................................................................
36
Emission Control System Information
.............................................
33
Engine
Oil
Change
.............................................................................
38
Fuel Sediment Cup Cleaning
............................................................
40
Importance of Maintenance
..............................................................
31
Maintenance Safety
...........................................................................
32
Spark Arrester Maintenance
.............................................................
42
Maintenance Schedule
......................................................................
37
Spark
Plug
Service
.............................................................................
41
53
background
-.
ZI
n:
0:
m:
si
Oi
2;
5:
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
..
+
I
rn
rn
z
G,
z
rn
-
..
0
I
rn
0
i-i
background
background

Specifications

Indexed Terms: Generator, Industrial

Honda EB5000 Questions and Answers

Questions and Answers