SS-GAMST-R32 www.goodmanmfg.com 01/25
Supersedes 12/24A
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited
Warranty, online registraon must be completed within 60 days of installaon. Online registraon and some of the addional
requirements are not required in Florida, California, or Québec. The duraon of warranty coverage in Texas and Florida diers in
some cases. Other limitaons and exclusions apply; refer to complete warranty details for a full list of limitaons and exclusions.
AMST Series
Product Features
• Internal factory-installed thermal expansion
valves for cooling and heat pump applicaons
• Direct drive, mul-speed ECM blower motor
• All-aluminum evaporator coil
• Coil mounng track for quick reposioning
• Opmized for use with R-32 refrigerant
• Cabinet air leakage less than 2.0% at 1.0 inch H₂O when
tested in accordance with ASHRAE standard 193
• Cabinet air leakage less than 1.4% at 0.5 inch H₂O when
tested in accordance with ASHRAE standard 193
• AHRI cered; ETL listed
• UL 60335 2-40 Compliant
• Factory installed R32 sensor designed
for lifespan of coil
• Rigid SmartFrame
™
cabinet
• Horizontal or vercal
conguraon capabilies
• 21" depth for easier ac access
• DecaBDE-free thermoplasc drain
pan with secondary drain connecons
• Screw-less sides and back helps to
reduce condensaon when installed
in humid locaons
• Foil-faced insulaon covers the internal
casing to reduce cabinet condensaon
• Galvanized, leather grain-embossed nish
• Glue-less cabinet insulaon retenon
• Tool-less lter access
• Field Installed 3 kW – 25 kW electric
heater kits available
Contents
Air Handler Nomenclature .................... 2
Heater Kit Nomenclature ...................... 2
Product Specicaons ........................... 3
Dimensions ............................................ 4
Airow Data ........................................... 5
Heat Kit Data .......................................... 7
Wiring Diagram ...................................... 9
Accessories .......................................... 12
Multi-Position, Multi-Speed,
ECM-Based Air Handler
with Internal TXV
1½ to 5 Tons

2 www.goodmanmfg.com SS-GAMST-R32
Nomenclature
A M S T 36 B U 1 3 0 0 A A
1 2 3 4 5,6 7 8 9 10 11,12 13 14
Minor Revision
Brand
D - Daikin Air Handler
A - Corporate Air Handler
Major Revision
Application
C - Ceiling Mounted
Factory Installed Electric Heat KW
M - Multi-Positional
00 -No Electric Heat
W - Wall Mounted
H - Horizontal Discharge Compatible
Multi-Positional
Refrigerant
3 - R32
Motor
S - MS-ECM
V - VS-ECM Communicating
Electrical
Expansion Device
1 208/230 V, 1 Phase, 60 Hz
E - Electronic Expansion Valve
F - Flowrator
T - Thermal Expansion Valve
Cabinet
Nominal Capacity
N - Uncased
12 - 1.0 Ton 36 - 3.0 Tons
P - Painted
18 - 1.5 Tons 42 - 3.5 Tons U - Unpainted
24 - 2.0 Tons 48 - 4.0 Tons
30 - 2.5 Tons 60 - 5.0 Tons
Cabinet Width
AC* Series AM* Series AW* Series
M - 43.25” B - 17.5" S - 20.2”
L - 49.25” C -21.0" L - 36.05”
D - 24.5"
H K T S D 2 5 D 1
1 2 3 4 5 6 7 8 9
Unit Type
HKTS - Electric heater
Kit for air handlers
Electrical
A - Single phase 208 V
Service Disconnect
B - Single phase 240 V
D - Service disconnect
1 - Single phase 208/240 V
N - No service disconnect 3 - Three phase 208/240 V
Cabinet Size
X - All Cabinets C - C Cabinet
D - D Cabinet
Heang Capacity @ 240 V
3 3.0 kW 10 9.6 kW
5 4.8 kW 15 14.4 kW
6 6.0 kW 19 19.2 kW with 170°F limit
8 8.0 kW 20 19.2 kW with 160°F limit
Note: 20X3 = 18.0 kW with 160°F limit
25 24.0 kW

SS-GAMST-R32 www.goodmanmfg.com 3
Product Specifications
AMST
24BU13*
AMST
30BU13*
AMST
36BU13*
AMST
36CU13*
AMST
42CU13*
AMST
48CU13*
AMST
60DU13*
Nominal Ratings
Cooling (Btu/h)
24,000 30,000 36,000 36,000 42,000 48,000 60,000
Nominal Tons
1.5 Ton 2.0 Ton 2.5 Ton 3 Ton 3.5 Ton 4 Ton 5 Ton
Blower
Diameter 10" 10" 10" 10" 10" 10" 11"
Width 6" 6" 6" 8" 8" 10" 10"
Coil Connections
Liquid
⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon
¾" ¾" ¾" ¾" ¾" ⅞" ⅞"
Coil Drain Connect (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾"
Electrical Data
Voltage 208/240 -1 208/240-1 208/240-1 208/240-1 208/240-1 208/240-1 208/240-1
Minimum Circuit Ampacity 5.8 5.6 5.6 7.1 5.9 7.1 8.6
Max. Overcurrent Device (Amps) 15 15 15 15 15 15 15
Min. / Max VAC 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253
Blower Motor
Full Load Amps (FLA) 4.6 4.5 4.5 5.7 5.7 5.7 6.9
Horsepower (HP) ¾ ¾ ¾ ¾ ¾ ¾ 1
Ship Weight (Lbs.) 112 129 129 153 153 153 167
*Airow rate @.3 stac
Note: Assumes dry coil; SCFM correcon for wet coil = 4% (208V / 240V)

4 www.goodmanmfg.com SS-GAMST-R32
Dimensions
Model A" B" C" D" E" F" G" H" J" K"
AMST24BU* 45 16⁵⁄
16
17⁹⁄
16
15¼ 12 12½ 9 12
9
⁄
16
2 13⅝
AMST30BU* 53⁷⁄
16
16⁵⁄
16
17⁹⁄
16
23
11
⁄
16
20
1
⁄
16
12½ 9 12¾ 2 13⅝
AMST36BU* 53⁷⁄
16
16⁵⁄
16
17⁹⁄
16
23
11
⁄
16
20
1
⁄
16
12½ 9 12¾ 2 13⅝
AMST36CU* 49 19
13
⁄
16
21⅛ 21
12
⁄
16
17¾ 16
1
⁄
16
9 12¾ 2 17⅛
AMST42CU* 53⁷⁄
16
19
13
⁄
16
21⅛ 21
12
⁄
16
18½ 16
10
⁄
16
9 12¾ 2 17⅛
AMST48CU* 58 19
13
⁄
16
21⅛ 26
3
⁄
16
22
15
⁄
16
14
10
⁄
16
10
13
⁄
16
6
13
⁄
16
2 17⅛
AMST06DU*
58 23¼ 24⅝ 26 223⁄4 17
11
⁄
16
12
9
⁄
16
13
13
⁄
16
2 20⅝

SS-GAMST-R32 www.goodmanmfg.com 5
Airflow Data
Model
Number
Speed
Tap
Static Pressure (in w.c)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
AMST24
BU1300AA
T1 825 800 745 730 660 645 560 550 460
T2 850 825 770 750 675 665 590 575 470
T3 935 910 865 850 790 780 715 705 620
T4 1,045 1,025 985 970 920 910 850 845 785
T5 1,100 1,080 1,035 1,020 970 960 905 900 840
T6 900 875 830 815 750 740 670 655 550
T7 1,030 1,005 960 950 900 890 825 820 760
T8 1,215 1,195 1,155 1,145 1,105 1,095 1,045 1,040 980
T9 1,215 1,195 1,155 1,145 1,105 1,095 1,045 1,040 980
AMST30
BU1300
T1 855 830 780 765 705 695 625 615 515
T2 920 895 845 830 780 770 710 700 615
T3 985 960 915 900 850 840 785 775 710
T4 1,070 1,050 1,005 995 945 935 890 885 830
T5 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960
T6 985 960 915 900 850 840 785 775 710
T7 1,070 1,050 1,005 995 945 935 890 885 830
T8 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960
T9 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960
AMST36
BU1300
T1 855 830 780 765 705 695 625 615 515
T2 920 895 845 830 780 770 710 700 615
T3 985 960 915 900 850 840 785 775 710
T4 1,070 1,050 1,005 995 945 935 890 885 830
T5 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960
T6 985 960 915 900 850 840 785 775 710
T7 1,070 1,050 1,005 995 945 935 890 885 830
T8 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960
T9 1,185 1,165 1,125 1,115 1,070 1,060 1,015 1,010 960
AMST36
CU1300
T1 1,070 1,035 960 935 830 810 700 690 610
T2 1,165 1,130 1,055 1,035 960 940 825 815 715
T3 1,285 1,255 1,190 1,170 1,100 1,085 990 980 885
T4 1,430 1,400 1,345 1,330 1,260 1,250 1,175 1,165 1,065
T5 1,560 1,530 1,470 1,455 1,390 1,380 1,310 1,300 1,235
T6 1,430 1,400 1,345 1,330 1,260 1,250 1,175 1,165 1,065
T7 1,735 1,710 1,660 1,645 1,580 1,570 1,510 1,500 1,440
T8 1,830 1,805 1,755 1,740 1,685 1,675 1,605 1,595 1,525
T9 1,830 1,805 1,755 1,740 1,685 1,675 1,605 1,595 1,525

6 www.goodmanmfg.com SS-GAMST-R32
Airflow DataAirflow Data (cont.)
Model
Number
Speed
Tap
Static Pressure (in w.c)
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
AMST42
CU1300
T1 1,165 1,140 1,085 1,065 990 975 895 880 765
T2 1,230 1,205 1,150 1,135 1,070 1,060 990 975 850
T3 1,410 1,385 1,335 1,325 1,280 1,270 1,195 1,185 1,115
T4 1,440 1,415 1,365 1,355 1,305 1,295 1,235 1,225 1,155
T5 1,495 1,470 1,425 1,415 1,365 1,355 1,305 1,295 1,220
T6 1,580 1,550 1,510 1,490 1,450 1,420 1,380 1,330 1,300
T7 1,410 1,385 1,335 1,325 1,280 1,270 1,195 1,185 1,115
T8 1,760 1,730 1,700 1,670 1,640 1,610 1,580 1,550 1,505
T9 1,760 1,730 1,700 1,670 1,640 1,610 1,580 1,550 1,505
AMST48
CU1300
T1 1,420 1,390 1,330 1,310 1,235 1,220 1,135 1,125 1,050
T2 1,465 1,435 1,375 1,355 1,280 1,265 1,165 1,155 1,065
T3 1,580 1,550 1,490 1,470 1,400 1,390 1,315 1,305 1,230
T4 1,635 1,610 1,560 1,545 1,480 1,470 1,400 1,390 1,315
T5 1,735 1,710 1,660 1,640 1,560 1,550 1,485 1,475 1,410
T6 1,420 1,390 1,330 1,310 1,235 1,220 1,135 1,125 1,050
T7 1,800 1,775 1,730 1,715 1,675 1,635 1,595 1,550 1,460
T8 1,820 1,795 1,750 1,735 1,680 1,670 1,605 1,595 1,525
T9 1,820 1,795 1,750 1,735 1,680 1,670 1,605 1,595 1,525
AMST60
DU1300
T1 1,215 1,175 1,095 1,070 975 950 790 780 700
T6 1,815 1,785 1,725 1,710 1,650 1,640 1,570 1,560 1,490
T7 1,360 1,325 1,250 1,230 1,145 1,125 1,010 990 850
T8 2,070 2,045 1,995 1,980 1,930 1,920 1,855 1,845 1,785
T9 1,970 1,945 1,895 1,880 1,815 1,805 1,740 1,730 1,660
Notes
1. Airow data indicated is at 230V without air lter in place.
2. Stac on table includes stac from media lter. Motor Speed Tap should be selected with media lter included in stac value.
3. The chart is for informaon only. For sasfactory operaon, external stac pressure must not exceed value shown on rang plate.
4. The cooling/heat pump speed tap should be selected based on the AHRI rang. Otherwise, select a speed tap that provides a minimum 350 CFM per outdoor ton.
5. Use the CFM adjustment fectors of 0.98 for horizontal le and 0.96 for horisontal right & downfow orientaons.
6. When applying a humidistat (normally closed), refer to the installaon and operang instrucons. The humidistat can adjust the cooling airow to 85%.
7. Airow test data is proved to sasfy minimum room area (Amin) and minimum airow at migaon mode (Qmin). See Table 9.

SS-GAMST-R32 www.goodmanmfg.com 7
Heat Kit Data
See Notes on Page 8.
Heater Kit Model
Circuit 1 (208V/240V) Circuit 2 (208V/240V) Single-Point Kit (208V/240V)
Heater Amps MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP²
AMST24BU1300AA 0/0 5.8/5.8 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 19.2/21.4 20/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 27.4/30.8 30/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 32.9/37.0 35/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 41.9/47.4 45/50 --- --- --- --- ---
HKTS*10X1 34.7/40.0 49.1/55.8 50/60 --- --- --- --- ---
HKTSD15XA/B 34.7/40.0 49.1/55.8 50/60 17.3/20 21.6/25 25/25 70.7/80.7 80/90
AMST30BU1300AA 0/0 5.6/5.6 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 19.1/21.2 20/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 27.2/30.6 30/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 32.8/36.9 35/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 41.8/47.2 45/50 --- --- --- --- ---
HKTS*10X1 34.7/40.0 49.0/55.6 50/60 --- --- --- --- ---
HKTSD15XA/B 34.7/40 49/55.6 50/60 17.3/20 21.6/25 25/25 70.6/80.6 80/90
AMST36BU1300AA 0/0 5.6/5.6 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 19.1/21.2 20/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 27.2/30.6 30/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 32.8/36.9 35/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 41.8/47.2 45/50 --- --- --- --- ---
HKTS*10X1 34.7/40.0 49.0/55.6 50/60 --- --- --- --- ---
HKTSD15XA/B 34.7/40 49/56 50/60 17.3/20 21.6/25 25/25 70.6/80.6 80/90
AMST36CU1300AA 0/0 7.1/7.1 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 20.6/22.8 25/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 28.8/32.1 30/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 34.2/38.4 35/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 43.2/48.8 45/50 --- --- --- --- ---
HKTS*10X1 34.7/40.0 50.5/57.1 60/60 --- --- --- --- ---
HKTS*15X3 ^ 0/0 7.1/7.1 15/15 30.0/34.6 37.5/43.3 40/45 --- ---
HKTSD15XA/B 34.7/40 50.5/57.1 60/60 17.3/20 21.6/25 25/25 72.1/82.1 80/90
HKTSD19CA/B 34.7/40 50.5/57.1 60/60 34.7/40 43.4/50 45/50 93.8/107 100/110
AMST42CU1300AA 0/0 7.1/7.1 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 20.6/22.8 20/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 28.8/32.1 30/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 34.2/38.4 35/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 43.2/48.8 45/50 --- --- --- --- ---
HKTS*10X1 34.7/40.0 50.5/57.1 60/60 --- --- --- --- ---
HKTS*15X3 ^ 0/0 7.1/7.1 15/15 30/34.6 37.5/43.3 40/45 --- ---
HKTSD15XA/B 34.7/40 50.5/57.1 60/60 17.3/20 21.6/25 25/25 72.1/82.1 80/90
HKTSD19CA/B 34.7/40 50.5/57.1 60/60 34.7/40 43.4/50 45/50 93.8/107 100/110

8 www.goodmanmfg.com SS-GAMST-R32
Heat Kit Data (cont.)
Heating kW Correction Factor
Supply Voltage 240 230 220 210 208
Correction Factor 1.00 0.92 0.84 0.77 0.75
Mulply the 240-volt heang capacity by correcon factors.
Heater Kit Model
Circuit 1 (208V/240V) Circuit 2 (208V/240V) Single-Point Kit (208V/240V)
Heater Amps MCA¹ MOP² Heater Amps MCA¹ MOP² MCA¹ MOP²
AMST48CU1300AA 0/0 7.1/7.1 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 20.6/22.8 25/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 28.8/32.1 30/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 34.2/38.4 35/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 43.2/48.8 45/50 --- --- --- --- ---
HKTS*10X1 34.7/40 50.5/57.1 60/60 --- --- --- --- ---
HKTS*15X3 ^ 0/0 7.1/7.1 15/15 30.0/34.6 37.5/43.3 40/45 --- ---
HKTSD15XA/B 34.7/40 50.5/57.1 60/60 17.3/20 21.6/25 25/25 72.1/82.1 80/90
HKTSD19CA/B 34.7/40 50.5/57.1 60/60 34.7/40 43.4/50 45/50 93.9/107 100/110
AMST60DU1300AA 0/0 8.6/8.6 15/15 --- --- --- --- ---
HKTSN03X1 10.8/12.5 22.2/24.3 25/25 --- --- --- --- ---
HKTS*05X1 17.3/20.0 30.3/33.6 35/35 --- --- --- --- ---
HKTSN06X1 21.7/25.0 35.7/39.9 40/40 --- --- --- --- ---
HKTS*08X1 28.9/33.3 44.7/50.3 45/60 --- --- --- --- ---
HKTS*10X1 34.7/40.0 52.0/58.6 60/60 --- --- --- --- ---
HKTS*15X3 ^ 0/0 8.6/8.6 15/15 30.0/34.6 37.5/43.3 40/45 --- ---
HKTSD15XA/B 34.7/40 52/58.6 60/60 17.3/20 21.7/25 25/25 73.6/83.6 80/90
HKTS*20X3 ^ 0/0 8.6/8.6 15/15 37.5/43.3 46.9/54.1 50/60 --- ---
HKTSD20DA/B 34.7/40 52/58.6 60/60 34.7/40 43.3/50 45/50 95.3/109 100/110
HKTSD25DA/B 34.7/40 52/58.6 60/60 52/60 65/75 70/80 117/134 125/150
¹Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.25
²Maximum Overcurrent Protecon = 2.25 X Motor Amps + Heater Amps
^ Three-phase Heater Kits (Circuit 1: Single-phase for Air Handlers Circuit 2: Three-phase for Heater Kits)
* D - Service disconnect, N - No service disconnect
--- indicates Not Required

SS-GAMST-R32 www.goodmanmfg.com 9
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring.
⚠ Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
Air Handler Wiring Diagram AMST**U1400** (1.5T-4T)
EHK
PLM
EHK
PLF
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
GND
EM
~
M
1
BL
BL
BK BLACK
BL BLUE
BR BROWN
GR GREEN
PU PURPLE
RD RED
WH WHITE
YL YELLOW
PK PINK
WIRE CODE
HIGH VOLTAGE
LOW VOLTAGE
EARTH GROUND
FIELD WIRING
HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL LOW VOLTAGE
CHASSIS GROUND
FACT ORY WIRING
R C G W1 W2 Y1 Y2 O DH T1 T2 T3 T4 T5TB
1
2
3
4
5
EM
PLF1
34
2
CR
0140A01419-A
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS
ORIGINAL (AT LEAST 105° C). USE COPPER CONDUCTORS ONLY.
USE N.E.C. CLASS 2 WIRE FOR ALL LOW VOLTAGE FIELD CONNECTIONS.
2. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT PURPLE WIRE FROM
TERMINAL 4 OF CR RELAY TO APPROPRIATE TAP AT TB.
SEE INSTALLATION
INSTRUCTIONS FOR FURTHER DETAILS ON ADJUSTING MOTOR.
3. DISCARD CONNECTOR EHK PLF WHEN INSTALLING OPTIONAL HEAT KIT.
4.
RED WIRE CONNECTED TO 240V TAP AT THE FACTORY AND BLACK WIRE
TO COM TREMINAL. FOR 208V SUPPLY POWER, MOVE RED WIRE
FROM 240 TAP TO THE 208V TAP.
5. LOW VOLTAGE TRANFORMER RATED 24VAC OUTPUT 75VA @ 3.125 AMP.
L2L1
BK
RD
WH
BR
BL
RD
BK
BK
EM
PLM2
EM
PLF2
EM
PLM1
BK
GR
RD
C
L
G
N
C
L
G
N
1
2
3
4
5
NOTES
PU
WH
BK
BR
YL
PUWHBK BR YL
BL
PU
WH
PU
POWER AND CONTROLS WIRING DIAGRAM
AIR HANDLER
RD
RD
BK
PK
RD BL WH BR
BL
BL
BL
PK
RD
BL
CR
10
BK BL
PU
PK
SEE NOTE 2
REF
PLM
REF PCB
EEV_IN
EEV_OUT
CTM_OUT
R_OUT
C
C
R
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
5V 2 1 C
PORT
SENSOR
NOT USED
BL
BL BL
GR
CB
TR
COM
BL
COMPONENT LEGEND
CB CIRCUIT BREAKER
CR CONTROL RELAY
EHK ELECTRIC HEATER KIT
EM EVAPORATOR MOTOR
GND GROUND
PCB CONTROL BOARD
PLF FEMALE PLUG
PLM MALE PLUG
REF REFRIGERANT
TB TERMINAL BOARD
TR TRANSFORMER
BL
GR
GR
BK
BK
TO HEATER KIT
(SEE NOTE 3)
208V - 230V / 1PH / 60Hz
III
III
(SEE NOTE 4 & 5)
READ THE INSTRUCTIONS
CLASS |||
III

10 www.goodmanmfg.com SS-GAMST-R32
Air Handler Wiring Diagram AMST60DU1400**
Wiring is subject to change. Always
refer to the wiring diagram on the
unit for the most up-to-date wiring.
⚠ Warning
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚡
EHK
PLM
EHK
PLF
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
GND
EM
~
M
1
BL
BL
BK BLACK
BL BLUE
BR BROWN
GR GREEN
PU PURPLE
RD RED
WH WHITE
YL YELLOW
PK PINK
WIRE CODE
HIGH VOLTAGE
OPTIONAL HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL LOW VOLTAGE
CHASSIS GROUND
FACTORY WIRING
R C G W1 W2 Y1 Y2 O DH T1 T2 T3 T4 T5
TB
1
2
3
4
5
EM
PLF1
0140A01420-A
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE OF INSULATION AS
ORIGINAL (AT LEAST 105° C). USE COPPER CONDUCTORS ONLY.
USE N.E.C. CLASS 2 WIRE FOR ALL LOW VOLTAGE FIELD CONNECTIONS.
2. SEE INSTALLATION INSTRUCTIONS FOR FURTHER DETAILS ON ADJUSTING MOTOR SPEED.
3. DISCARD CONNECTOR EHK PLF WHEN INSTALLING OPTIONAL HEAT KIT.
4. RED WIRE CONNECTED TO 240V TAP AT THE FACTORY AND BLACK WIRE
TO COM TREMINAL. FOR 208V SUPPLY POWER, MOVE RED WIRE
FROM 240 TAP TO THE 208V TAP.
5. LOW VOLTAGE TRANFORMER RATED 24VAC OUTPUT 75VA @ 3.125 AMP.
L2L1
BK
RD
WH
BR
BL
RD
BK
BK
EM
PLM2
EM
PLF2
EM
PLM1
BK
GR
RD
C
L
G
N
C
L
G
N
1
2
3
4
5
NOTES
PU
WH
BK
BR
YL
PUWHBK BR YL
BL
POWER AND CONTROLS WIRING DIAGRAM
AIR HANDLER
RD
PK
BL
BK
RD BL WH BR
BL
RD
BL
PK
WH
PU
WH
PU
SEE NOTE 2
REF
PLM
REF PCB
EEV_IN
EEV_OUT
CTM_OUT
R_OUT
C
C
R
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
5V 2 1 C
PORT
SENSOR
NOT USED
GR
BL BL
GR
BL
CB
TR
COM
PK
GR
BK
BK
YL
BRBR
BL
YL
COMPONENT LEGEND
CB CIRCUIT BREAKER
EHK ELECTRIC HEATER KIT
EM EVAPORATOR MOTOR
GND GROUND
PCB CONTROL BOARD
PLF FEMALE PLUG
PLM MALE PLUG
REF REFRIGERANT
TB TERMINAL BOARD
TR TRANSFORMER
TO HEATER KIT
(SEE NOTE 3)
III
III
(SEE NOTE 4 & 5)
READ THE INSTRUCTIONS
CLASS |||
III
HIGH VOLTAGE
LOW VOLTAGE
EARTH GROUND
FIELD WIRING
208V - 230V / 1PH / 60Hz

SS-GAMST-R32 www.goodmanmfg.com 11
Accessories
Downflow Kits
DFKE-02 DFKE-03
AMST24BU1300** AMST48CU1300**
AMST30BU1300** AMST60DU1300**
AMST36BU1300**
AMST36CU1300**
AMST42CU1300**
Condensate Management Kit
CMK0018 CMK0019 CMK0020
AMST24BU1300** AMST30BU1300** AMST48CU1300**
AMST36CU1300** AMST36BU1300** AMST60DU1300**
AMST42CU1300**
High Humidity Kit
HHK0004 HHK0005 HHK0007
AMST24BU1300** AMST36CU1300**
AMST60DU1300**
AMST30BU1300** AMST42CU1300**
AMST36BU1300** AMST48CU1300**
Filters
Chassis Part # Size
B ALFH16201E 16.0” x 20.0”
C ALFH1912201E 19.5” x 20.0”
D ALFH20231E 23.0” x 20.0”
Single Point Wiring Kit (SPW-01)
HEATER KIT MODEL SPWK-B SPWK-C SPWK-D
HKTSD15XA
AMST24BU1300**
AMST30BU1300**
AMST36CU1300**
AMST42CU1300**
AMST48CU1300**
AMST60DU1300**
HKTSD15XB
HKTSD19CA
HKTSD19CB
HKTSD20DA
AMST60DU1300**
HKTSD20DB
HKTSD25DA
AMST60DU1300**
HKTSD25DB
FRPP Drain Pan Kit for UVC application
Module FRPP drain pan kit
AMST24BU1300** UVPK01
AMST30BU1300**
UVPK02
AMST36BU1300**
AMST36CU1300** UVPK03
AMST42CU1300** UVPK04
AMST48CU1300** UVPK05
AMST60DU1300** UVPK07
R32 ZONING ACCESSORY KIT
KIT NUMBER Models
0230K00007 All AMST Models

12 www.goodmanmfg.com SS-GAMST-R32
Our connuing commitment to quality products may mean a change in specicaons without noce.
©2024 • Houston, Texas • Printed in the USA
Notes