RV5
Power Hub
User Manual V1.0
Important instructions
• Read and understand this manual before use and keep it handy for future
reference.
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.

Tips !
1. Before first use, make sure the connected batteries are in good condition and
functioning properly.
2. Only connect devices that meet the voltage requirements for each port.
3. Do not connect the unit's AC output to the grid.
4. Ensure proper ventilation if the unit is placed in a confined space.
5. Do not remove the wiring covers or touch exposed terminals while the unit is in
use.
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.

Legal Information
Copyright © 2025 Shenzhen PowerOak Newener Co., Ltd. All Rights Reserved.
No reproduction or transmission of any part of this document is permitted without
the prior written consent of Shenzhen PowerOak Newener Co., Ltd.
Notice
BLUETTI's products and services are subject to the terms and conditions agreed upon
during purchase. Some aspects described in this manual may not be available under
your purchase contract. Unless otherwise specified in the contract, BLUETTI makes no
express or implied representations or warranties regarding the contents of this
manual.
The contents of this manual are subject to change without notice. Please obtain the
latest version from BLUETTI official website.
If you have any questions or concerns about this manual, please contact BLUETTI
support for further assistance.
Shenzhen PowerOak Newener Co., Ltd.
19F, Block A, Kaidaer Bldg., No. 168 Tong Sha Rd, Shenzhen, China
Website: https://www.bluettipower.com/
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.

About the Manual
Contents
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
1. Safety Instructions------------------------------------------------------------------------------------
1.1 General Instructions ------------------------------------------------------------------------------
1.2 Installation Safety----------------------------------------------------------------------------------------------
1.3 Battery Safety --------------------------------------------------------------------------------------------------
1.4 Electrical Safety -----------------------------------------------------------------------------------
1.5 Handling Requirements-------------------------------------------------------------------------
2. What's in the Box -------------------------------------------------------------------------------------------------
3. Get to Know Your RV5 -------------------------------------------------------------------------------
3.1 System Overview ---------------------------------------------------------------------------------
3.2 RV5 Introduction----------------------------------------------------------------------------------
4. Install & Wire Your RV5 ------------------------------------------------------------------------------
4.1 Required Tools -------------------------------------------------------------------------------------------------
4.2 Mount the RV5 ------------------------------------------------------------------------------------------------
4.3 Wiring and Fuses---------------------------------------------------------------------------------
4.4 Wiring Instructions Overview -------------------------------------------------------------------
4.5 AC Input Wiring ----------------------------------------------------------------------------------
4.6 AC Output Wiring--------------------------------------------------------------------------------
4.7 Battery Wiring ------------------------------------------------------------------------------------
4.8 DC Input Wiring ----------------------------------------------------------------------------------
4.9 DC Output Wiring --------------------------------------------------------------------------------
4.10 Grounding ------------------------------------------------------------------------------------------------------
4.11 CAN Communication Wiring & Configuration--------------------------------------------------------
07
07
10
11
12
13
14
15
15
18
21
21
22
27
28
30
33
34
38
41
42
43

1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
5. Use Your RV5 -------------------------------------------------------------------------------------------------------
5.1 Power On/Off --------------------------------------------------------------------------------------------------
5.2 Initial Setup ----------------------------------------------------------------------------------------------------
5.3 Configure Your RV5 ------------------------------------------------------------------------------
5.4 Button Control------------------------------------------------------------------------------------
6. Maintenance and Care ------------------------------------------------------------------------------
7. Specifications------------------------------------------------------------------------------------------------------
8. Troubleshooting --------------------------------------------------------------------------------------------------
Appendix 1------------------------------------------------------------------------------------------------------------ ---
Appendix 2 --------------------------------------------------------------------------------------------------------------
Appendix 3 --------------------------------------------------------------------------------------------------------------
Compliance -------------------------------------------------------------------------------------------------------------
1. Sécurité Instructions -----------------------------------------------------------------------------------------------
1.1
Général Instructions----------------------------------------------------------------------------
1.2 Installation Safety -----------------------------------------------------------------------------
1.3 Batterie Sécurité---------------------------------------------------------------------------------------------
1.4 Électrique Sécurité -------------------------------------------------------------------------------
1.5 Manutention Exigences--------------------------------------------------------------------------
Conformité---------------------------------------------------------------------------------------------------------------
45
45
47
47
48
49
49
51
54
55
56
57
62
62
65
66
68
69
70

About the Manual
Symbol Conventions
This manual uses the following symbols to highlight important information:
Purpose
This user manual describes the installation, electrical connection, commissioning, maintenance
and troubleshooting of RV5. Please read and understand all instructions in this manual before
use.
Danger
Warning
Caution
Attention
Note
It indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
It indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
It contains important additional information as well as useful tips for safe,
efficient and hassle-free operation of the RV5.
It indicates a potentially hazardous situation which, if not avoided,
could cause substantial damage to property and the environment.
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.

1. Safety Instructions
1.1 General Instructions
1.1.1 Statement
SAVE THESE INSTRUCTIONS – This manual contains important safety and operating
instructions for RV5.
Before installing, operating, or maintaining this unit, please read this manual thoroughly and
follow all safety precautions indicated on the unit and in this manual.
Look for and follow all "Note", "Attention", "Caution", "Warning", and "Danger" statements in
this manual. The safety guidelines provided herein do not cover all possible safety consider
ations. Please follow all relevant international, national, or regional standards, as well as
industry practices. Our company shall not be liable for damages resulting from non-compli
ance with these safety requirements or standards.
For issues or operations not covered in this manual, please contact BLUETTI support,
otherwise we are not responsible for any damage or injury caused by unauthorized operations.
Always consider the actual on-site conditions when using the unit. Use it only in environments
that meet the requirements outlined in this manual. Failure to do so may cause equipment
malfunctions or damage, which are not covered by the warranty. Our company is not liable
for any injuries or property damage caused by improper use.
Thus, for proper installation and use of this unit, it's crucial to adhere to the following guide
lines:
1. Always operate or store the unit in the conditions specified in this manual.
2. CAUTION – To reduce risk of injury, charge only LiFePO4 or lead-acid batteries type
rechargeable batteries . Other types of batteries may burst causing personal injury and
damage.
3. Do not expose the unit to rain or snow.
4. Use of an attachment not recommended or sold by us may result in a risk of fire, electric
shock, or injury to persons.
5. Do not disassemble the RV5; take it to a qualified serviceman when service or repair is
required. Incorrect reassembly may result in a risk of electric shock or fire.
6. To reduce risk of electric shock, unplug the RV5 from the outlet before attempting any
maintenance or cleaning. Turning off controls will not eliminate this risk.
7. The installation and ambient conditions must comply with the regulations in the relevant
international, national or regional standards.
8. Avoid unauthorized disassembly, equipment alterations, or software code modifications.
9. Our company shall also not be liable for the following situations or their consequences:
• Damage caused by force majeure events such as earthquakes, fires, storms, floods, or
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
IMPORTANT SAFETY INSTRUCTIONS
JUST POWER ON 07
EN

1.1.2 General Requirements
Attention
Follow these guidelines for proper use.
Follow these guidelines for proper use.
Danger
mudslides.
• Transport-related damages during customer handling.
• Equipment damage due to improper storage conditions as outlined in the manual.
• Hardware damage or data loss resulting from customer negligence, improper use, or
intentional damage.
• System damage caused by third parties or customers, including improper handling or
installation not in line with the manual's instructions.
• Damage from adjustments, modifications, or removal of labels not authorized in the
manual.
• Use of the unit in environments not compliant with relevant international, national, or
regional standards.
• installation or operation by unauthorized personnel.
• Use of customer-provided materials or tools that do not meet local legal requirements or
relevant standards.
• This unit is not intended for use with devices that have high-performance requirements for
UPS (Uninterruptible Power Supply), including but not limited to data servers, workstations,
medical equipment, and similar devices. Our company shall not be liable for any data loss or
equipment damage resulting from the violation of this requirement.
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
EN
JUST POWER ON
08

Note
Comply with applicable laws and regulations.
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
• When handling, installing, wiring, or maintaining this product, comply with the country or
region's legal regulations and standards.
• Use materials and tools that meet applicable legal requirements and standards.
• Understand the operational principles and standards relevant to the energy storage system
in the location.
JUST POWER ON 09
EN

1.2 Installation Safety
Danger
Follow these guidelines for proper use.
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
1. Avoid working with live electrical components.
2. Before installation, double check the unit for any signs of damage or defects to minimize
potential risks.
3. Make sure the unit and all associated switches are turned off (not in sleep mode) to prevent
electric shock.
4. Do not touch any terminal while the unit is running, as it may pose a risk of electric shock.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
1.2.1 General Requirements
1. After installation, remove the idle package materials from the site such as cardboard, foam,
plastic, nylon ties, etc.
2. Keep people other than the installers away from the site.
3. Handle the unit and accessories carefully during transport; use original or protective packag-
ing.
4. Seal wiring ports securely with fireproof and waterproof materials.
5. Do not alter or cover equipment markings or nameplates.
6. Check and make sure all safe guards, including screws and waterproof rings, are in place and
properly tightened.
7. Clean the unit and accessories with a soft cloth; avoid water or harsh chemicals.
8. Do not make any changes to the unit's structure, installation sequence, or any other aspects
without permission.
1.2.2 Drilling Requirements
When drilling holes in the wall or on the ground, follow these safety measures:
1. Wear goggles and protective gloves at all times.
2. Shield the unit to prevent debris from falling into it, and remove all debris after drilling.
3. Drill holes on the unit is forbidden as it may damage the the unit’s electromagnetic shielding
performance. The metal shavings may cause short circuits on the circuit board.
4. Make sure to check for any embedded pipes or cables before drilling to prevent short circuits
or other hazards.
1.2.3 Location Requirements
1. Locate RV5 away from battery in a separate, well ventilated compartment.
2. Never place device directly above battery; gases from battery will corrode and damage
device.
3. Never allow battery acid to drip on device when reading gravity or filling battery.
4. Do not operate device in a closed-in area or restrict ventilation in any way.
1.3 Battery Safety
1.3.1 Disclaimer
Our company shall not be liable for equipment malfunctions, component damage, personal
injury, property loss, or other issues caused by:
• Using damaged or modified battery packs or devices.
• Using battery types not specified in the manual or batteries with unsupported voltage.
• Failing to follow the battery user manual for proper use and handling.
• Incorrect battery operational settings.
• Short circuits, damage, drops, or leaks due to improper use or connections.
1.3.2 General Requirements
1. WARNING – RISK OF EXPLOSIVE GASES.
2. CAUTION – WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS
REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING THE UNIT IN
THE VICINITY OF THE BATTERY, YOU READ THIS MANUAL AND FOLLOW THE
INSTRUCTIONS EXACTLY.
3. To reduce risk of battery explosion, follow these instructions and those published by battery
manufacturer and manufacturer of any unit you intend to use in vicinity of battery. Review
cautionary marking on these products and on engine.
4. This unit is intended to recharge batteries. The battery that is connected to this product is
only suitable if it complies with the given battery standard for that battery type and is provided
with a battery management system that will monitor and control the electrical and thermal
health of the battery during charging. When installing this device, the battery is to be verified
as in compliance with the applicable battery standard.
5. CAUTION – It's recommended to use battery packs provided by BLUETTI. Unverified,
damaged, or modified batteries may pose fire, explosion, or injury risks. If using a third-party
battery, follow its user manual for proper use and maintenance.
6. If the battery has no built-in protection features, install a properly rated fuse or DC circuit
breaker at the terminal.
7. Use short battery cables to minimize heat buildup and improve performance.
8. WARNING –Never reverse the battery's positive and negative terminals. Damage caused by
incorrect connection is not covered under warranty.
9. For marine use, pair this unit with Epad or any compatible voltage and current monitoring
device to track the charging process.
1.3.3 Personal Precautions
1. Someone should be within range of your voice or close enough to come to your aid when
you work near a lead-acid battery.
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or
eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working
near battery.
4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters
eye, immediately flood eye with running cold water for at least 10 min and get medical
attention immediately.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
6. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or
short-circuit battery or other electrical part that may cause explosion.
7. Remove personal metal items such as rings, bracelets, necklaces, and watches when
working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high
enough to weld a ring or the like to metal, causing a severe burn.
8. NEVER charge a frozen battery.
9. If necessary to remove battery from vessel, always remove grounded terminal from battery
first. Make sure all accessories in the vessels are off, so as not to cause an arc.
10. Be sure area around battery is well ventilated.
11. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
12. Study all battery manufacturer's specific precautions such as removing or not removing
cell caps while charging and recommended rates of charge.
13. Add distilled water in each cell until battery acid reaches level specified by battery
manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery without
cell caps, carefully follow manufacturer's recharging instructions.
1.3.4 DC Connection Precautions
1. Connect and disconnect battery connections only after setting any device switches to off
position and removing AC cord from electric outlet or opening AC disconnect.
2. EXTERNAL CONNECTIONS TO CHARGER SHALL COMPLY WITH THE UNITED STATES
COAST GUARD ELECTRICAL REGULATIONS (33CFR183, SUB PART I).
1.4 Electrical Safety
1.4.1 General Requirements
1. Ensure all electrical connections comply with national/regional electrical standards.
2. User-provided cables should meet local legal requirements.
3. Use specialized insulated tools for electrical work.
1.4.2 Grounding Requirements
1. Before operating the unit, always confirm that it is properly grounded to reduce the risk of
electric shock.
2. Take care not to damage the grounding conductor.
3. Connections to unit should comply with all local codes and ordinances.
4. According to IEC62109-1 guidelines, if the ground wire is damaged or disconnected, connect
a protective ground wire to ensure safe use of the unit. Ensure the ground wire meets at least
one of these criteria:
a. Use a single-core outdoor copper cable with a conductor cross-sectional area of ≥10 mm² if
the PE terminal in the AC connector is not connected.
b. Use cables with the same wire diameter as the AC output cables, grounding both the PE
terminal in the AC connector and the chassis grounding screw separately.
1.4.3 Wiring Requirements
1. Keep cables at least 1.18in (30mm) away from heat sources and devices that emit heat, as
high temperatures can cause insulation to age or become damaged.
2. Bundle cables of similar types together to reduce electromagnetic interference. Keep
different types of cables at least 1.18in (30mm) apart and avoid twisting or crossing them.
3. All cable must be securely connected, well-insulated, and of suitable specifications.
4. Take necessary measures to protect cables when passing through pipes or holes.
5. in cold temperatures, severe impacts or vibrations can cause the plastic coating of cables to
become brittle and crack. To ensure safe installation:
a. Lay and install all cables at temperatures above 0°C (32°F). Handle cables with care, especially
when working in cold environments.
b. If cables have been stored in temperatures below 0°C (32°F), store them at room tempera-
ture for at least 24 hours before installation.
1.5 Handling Requirements
Table 1-1 Recommended Number of People Based on the Weight of Product
EN
JUST POWER ON
10

1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
1. Avoid working with live electrical components.
2. Before installation, double check the unit for any signs of damage or defects to minimize
potential risks.
3. Make sure the unit and all associated switches are turned off (not in sleep mode) to prevent
electric shock.
4. Do not touch any terminal while the unit is running, as it may pose a risk of electric shock.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
1.2.1 General Requirements
1. After installation, remove the idle package materials from the site such as cardboard, foam,
plastic, nylon ties, etc.
2. Keep people other than the installers away from the site.
3. Handle the unit and accessories carefully during transport; use original or protective packag-
ing.
4. Seal wiring ports securely with fireproof and waterproof materials.
5. Do not alter or cover equipment markings or nameplates.
6. Check and make sure all safe guards, including screws and waterproof rings, are in place and
properly tightened.
7. Clean the unit and accessories with a soft cloth; avoid water or harsh chemicals.
8. Do not make any changes to the unit's structure, installation sequence, or any other aspects
without permission.
1.2.2 Drilling Requirements
When drilling holes in the wall or on the ground, follow these safety measures:
1. Wear goggles and protective gloves at all times.
2. Shield the unit to prevent debris from falling into it, and remove all debris after drilling.
3. Drill holes on the unit is forbidden as it may damage the the unit’s electromagnetic shielding
performance. The metal shavings may cause short circuits on the circuit board.
4. Make sure to check for any embedded pipes or cables before drilling to prevent short circuits
or other hazards.
1.2.3 Location Requirements
1. Locate RV5 away from battery in a separate, well ventilated compartment.
2. Never place device directly above battery; gases from battery will corrode and damage
device.
3. Never allow battery acid to drip on device when reading gravity or filling battery.
4. Do not operate device in a closed-in area or restrict ventilation in any way.
1.3 Battery Safety
1.3.1 Disclaimer
Our company shall not be liable for equipment malfunctions, component damage, personal
injury, property loss, or other issues caused by:
• Using damaged or modified battery packs or devices.
• Using battery types not specified in the manual or batteries with unsupported voltage.
• Failing to follow the battery user manual for proper use and handling.
• Incorrect battery operational settings.
• Short circuits, damage, drops, or leaks due to improper use or connections.
1.3.2 General Requirements
1. WARNING – RISK OF EXPLOSIVE GASES.
2. CAUTION – WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS
REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING THE UNIT IN
THE VICINITY OF THE BATTERY, YOU READ THIS MANUAL AND FOLLOW THE
INSTRUCTIONS EXACTLY.
3. To reduce risk of battery explosion, follow these instructions and those published by battery
manufacturer and manufacturer of any unit you intend to use in vicinity of battery. Review
cautionary marking on these products and on engine.
4. This unit is intended to recharge batteries. The battery that is connected to this product is
only suitable if it complies with the given battery standard for that battery type and is provided
with a battery management system that will monitor and control the electrical and thermal
health of the battery during charging. When installing this device, the battery is to be verified
as in compliance with the applicable battery standard.
5. CAUTION – It's recommended to use battery packs provided by BLUETTI. Unverified,
damaged, or modified batteries may pose fire, explosion, or injury risks. If using a third-party
battery, follow its user manual for proper use and maintenance.
6. If the battery has no built-in protection features, install a properly rated fuse or DC circuit
breaker at the terminal.
7. Use short battery cables to minimize heat buildup and improve performance.
8. WARNING –Never reverse the battery's positive and negative terminals. Damage caused by
incorrect connection is not covered under warranty.
9. For marine use, pair this unit with Epad or any compatible voltage and current monitoring
device to track the charging process.
1.3.3 Personal Precautions
1. Someone should be within range of your voice or close enough to come to your aid when
you work near a lead-acid battery.
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or
eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working
near battery.
4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters
eye, immediately flood eye with running cold water for at least 10 min and get medical
attention immediately.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
6. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or
short-circuit battery or other electrical part that may cause explosion.
7. Remove personal metal items such as rings, bracelets, necklaces, and watches when
working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high
enough to weld a ring or the like to metal, causing a severe burn.
8. NEVER charge a frozen battery.
9. If necessary to remove battery from vessel, always remove grounded terminal from battery
first. Make sure all accessories in the vessels are off, so as not to cause an arc.
10. Be sure area around battery is well ventilated.
11. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
12. Study all battery manufacturer's specific precautions such as removing or not removing
cell caps while charging and recommended rates of charge.
13. Add distilled water in each cell until battery acid reaches level specified by battery
manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery without
cell caps, carefully follow manufacturer's recharging instructions.
1.3.4 DC Connection Precautions
1. Connect and disconnect battery connections only after setting any device switches to off
position and removing AC cord from electric outlet or opening AC disconnect.
2. EXTERNAL CONNECTIONS TO CHARGER SHALL COMPLY WITH THE UNITED STATES
COAST GUARD ELECTRICAL REGULATIONS (33CFR183, SUB PART I).
1.4 Electrical Safety
1.4.1 General Requirements
1. Ensure all electrical connections comply with national/regional electrical standards.
2. User-provided cables should meet local legal requirements.
3. Use specialized insulated tools for electrical work.
1.4.2 Grounding Requirements
1. Before operating the unit, always confirm that it is properly grounded to reduce the risk of
electric shock.
2. Take care not to damage the grounding conductor.
3. Connections to unit should comply with all local codes and ordinances.
4. According to IEC62109-1 guidelines, if the ground wire is damaged or disconnected, connect
a protective ground wire to ensure safe use of the unit. Ensure the ground wire meets at least
one of these criteria:
a. Use a single-core outdoor copper cable with a conductor cross-sectional area of ≥10 mm² if
the PE terminal in the AC connector is not connected.
b. Use cables with the same wire diameter as the AC output cables, grounding both the PE
terminal in the AC connector and the chassis grounding screw separately.
1.4.3 Wiring Requirements
1. Keep cables at least 1.18in (30mm) away from heat sources and devices that emit heat, as
high temperatures can cause insulation to age or become damaged.
2. Bundle cables of similar types together to reduce electromagnetic interference. Keep
different types of cables at least 1.18in (30mm) apart and avoid twisting or crossing them.
3. All cable must be securely connected, well-insulated, and of suitable specifications.
4. Take necessary measures to protect cables when passing through pipes or holes.
5. in cold temperatures, severe impacts or vibrations can cause the plastic coating of cables to
become brittle and crack. To ensure safe installation:
a. Lay and install all cables at temperatures above 0°C (32°F). Handle cables with care, especially
when working in cold environments.
b. If cables have been stored in temperatures below 0°C (32°F), store them at room tempera-
ture for at least 24 hours before installation.
1.5 Handling Requirements
Table 1-1 Recommended Number of People Based on the Weight of Product
JUST POWER ON 11
EN

1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
1. Avoid working with live electrical components.
2. Before installation, double check the unit for any signs of damage or defects to minimize
potential risks.
3. Make sure the unit and all associated switches are turned off (not in sleep mode) to prevent
electric shock.
4. Do not touch any terminal while the unit is running, as it may pose a risk of electric shock.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
1.2.1 General Requirements
1. After installation, remove the idle package materials from the site such as cardboard, foam,
plastic, nylon ties, etc.
2. Keep people other than the installers away from the site.
3. Handle the unit and accessories carefully during transport; use original or protective packag-
ing.
4. Seal wiring ports securely with fireproof and waterproof materials.
5. Do not alter or cover equipment markings or nameplates.
6. Check and make sure all safe guards, including screws and waterproof rings, are in place and
properly tightened.
7. Clean the unit and accessories with a soft cloth; avoid water or harsh chemicals.
8. Do not make any changes to the unit's structure, installation sequence, or any other aspects
without permission.
1.2.2 Drilling Requirements
When drilling holes in the wall or on the ground, follow these safety measures:
1. Wear goggles and protective gloves at all times.
2. Shield the unit to prevent debris from falling into it, and remove all debris after drilling.
3. Drill holes on the unit is forbidden as it may damage the the unit’s electromagnetic shielding
performance. The metal shavings may cause short circuits on the circuit board.
4. Make sure to check for any embedded pipes or cables before drilling to prevent short circuits
or other hazards.
1.2.3 Location Requirements
1. Locate RV5 away from battery in a separate, well ventilated compartment.
2. Never place device directly above battery; gases from battery will corrode and damage
device.
3. Never allow battery acid to drip on device when reading gravity or filling battery.
4. Do not operate device in a closed-in area or restrict ventilation in any way.
1.3 Battery Safety
1.3.1 Disclaimer
Our company shall not be liable for equipment malfunctions, component damage, personal
injury, property loss, or other issues caused by:
• Using damaged or modified battery packs or devices.
• Using battery types not specified in the manual or batteries with unsupported voltage.
• Failing to follow the battery user manual for proper use and handling.
• Incorrect battery operational settings.
• Short circuits, damage, drops, or leaks due to improper use or connections.
1.3.2 General Requirements
1. WARNING – RISK OF EXPLOSIVE GASES.
2. CAUTION – WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS
REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING THE UNIT IN
THE VICINITY OF THE BATTERY, YOU READ THIS MANUAL AND FOLLOW THE
INSTRUCTIONS EXACTLY.
3. To reduce risk of battery explosion, follow these instructions and those published by battery
manufacturer and manufacturer of any unit you intend to use in vicinity of battery. Review
cautionary marking on these products and on engine.
4. This unit is intended to recharge batteries. The battery that is connected to this product is
only suitable if it complies with the given battery standard for that battery type and is provided
with a battery management system that will monitor and control the electrical and thermal
health of the battery during charging. When installing this device, the battery is to be verified
as in compliance with the applicable battery standard.
5. CAUTION – It's recommended to use battery packs provided by BLUETTI. Unverified,
damaged, or modified batteries may pose fire, explosion, or injury risks. If using a third-party
battery, follow its user manual for proper use and maintenance.
6. If the battery has no built-in protection features, install a properly rated fuse or DC circuit
breaker at the terminal.
7. Use short battery cables to minimize heat buildup and improve performance.
8. WARNING –Never reverse the battery's positive and negative terminals. Damage caused by
incorrect connection is not covered under warranty.
9. For marine use, pair this unit with Epad or any compatible voltage and current monitoring
device to track the charging process.
1.3.3 Personal Precautions
1. Someone should be within range of your voice or close enough to come to your aid when
you work near a lead-acid battery.
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or
eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working
near battery.
4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters
eye, immediately flood eye with running cold water for at least 10 min and get medical
attention immediately.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
6. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or
short-circuit battery or other electrical part that may cause explosion.
7. Remove personal metal items such as rings, bracelets, necklaces, and watches when
working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high
enough to weld a ring or the like to metal, causing a severe burn.
8. NEVER charge a frozen battery.
9. If necessary to remove battery from vessel, always remove grounded terminal from battery
first. Make sure all accessories in the vessels are off, so as not to cause an arc.
10. Be sure area around battery is well ventilated.
11. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
12. Study all battery manufacturer's specific precautions such as removing or not removing
cell caps while charging and recommended rates of charge.
13. Add distilled water in each cell until battery acid reaches level specified by battery
manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery without
cell caps, carefully follow manufacturer's recharging instructions.
1.3.4 DC Connection Precautions
1. Connect and disconnect battery connections only after setting any device switches to off
position and removing AC cord from electric outlet or opening AC disconnect.
2. EXTERNAL CONNECTIONS TO CHARGER SHALL COMPLY WITH THE UNITED STATES
COAST GUARD ELECTRICAL REGULATIONS (33CFR183, SUB PART I).
1.4 Electrical Safety
1.4.1 General Requirements
1. Ensure all electrical connections comply with national/regional electrical standards.
2. User-provided cables should meet local legal requirements.
3. Use specialized insulated tools for electrical work.
1.4.2 Grounding Requirements
1. Before operating the unit, always confirm that it is properly grounded to reduce the risk of
electric shock.
2. Take care not to damage the grounding conductor.
3. Connections to unit should comply with all local codes and ordinances.
4. According to IEC62109-1 guidelines, if the ground wire is damaged or disconnected, connect
a protective ground wire to ensure safe use of the unit. Ensure the ground wire meets at least
one of these criteria:
a. Use a single-core outdoor copper cable with a conductor cross-sectional area of ≥10 mm² if
the PE terminal in the AC connector is not connected.
b. Use cables with the same wire diameter as the AC output cables, grounding both the PE
terminal in the AC connector and the chassis grounding screw separately.
1.4.3 Wiring Requirements
1. Keep cables at least 1.18in (30mm) away from heat sources and devices that emit heat, as
high temperatures can cause insulation to age or become damaged.
2. Bundle cables of similar types together to reduce electromagnetic interference. Keep
different types of cables at least 1.18in (30mm) apart and avoid twisting or crossing them.
3. All cable must be securely connected, well-insulated, and of suitable specifications.
4. Take necessary measures to protect cables when passing through pipes or holes.
5. in cold temperatures, severe impacts or vibrations can cause the plastic coating of cables to
become brittle and crack. To ensure safe installation:
a. Lay and install all cables at temperatures above 0°C (32°F). Handle cables with care, especially
when working in cold environments.
b. If cables have been stored in temperatures below 0°C (32°F), store them at room tempera-
ture for at least 24 hours before installation.
1.5 Handling Requirements
Table 1-1 Recommended Number of People Based on the Weight of Product
EN
JUST POWER ON
12

1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
1. Avoid working with live electrical components.
2. Before installation, double check the unit for any signs of damage or defects to minimize
potential risks.
3. Make sure the unit and all associated switches are turned off (not in sleep mode) to prevent
electric shock.
4. Do not touch any terminal while the unit is running, as it may pose a risk of electric shock.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
1.2.1 General Requirements
1. After installation, remove the idle package materials from the site such as cardboard, foam,
plastic, nylon ties, etc.
2. Keep people other than the installers away from the site.
3. Handle the unit and accessories carefully during transport; use original or protective packag-
ing.
4. Seal wiring ports securely with fireproof and waterproof materials.
5. Do not alter or cover equipment markings or nameplates.
6. Check and make sure all safe guards, including screws and waterproof rings, are in place and
properly tightened.
7. Clean the unit and accessories with a soft cloth; avoid water or harsh chemicals.
8. Do not make any changes to the unit's structure, installation sequence, or any other aspects
without permission.
1.2.2 Drilling Requirements
When drilling holes in the wall or on the ground, follow these safety measures:
1. Wear goggles and protective gloves at all times.
2. Shield the unit to prevent debris from falling into it, and remove all debris after drilling.
3. Drill holes on the unit is forbidden as it may damage the the unit’s electromagnetic shielding
performance. The metal shavings may cause short circuits on the circuit board.
4. Make sure to check for any embedded pipes or cables before drilling to prevent short circuits
or other hazards.
1.2.3 Location Requirements
1. Locate RV5 away from battery in a separate, well ventilated compartment.
2. Never place device directly above battery; gases from battery will corrode and damage
device.
3. Never allow battery acid to drip on device when reading gravity or filling battery.
4. Do not operate device in a closed-in area or restrict ventilation in any way.
1.3 Battery Safety
1.3.1 Disclaimer
Our company shall not be liable for equipment malfunctions, component damage, personal
injury, property loss, or other issues caused by:
• Using damaged or modified battery packs or devices.
• Using battery types not specified in the manual or batteries with unsupported voltage.
• Failing to follow the battery user manual for proper use and handling.
• Incorrect battery operational settings.
• Short circuits, damage, drops, or leaks due to improper use or connections.
1.3.2 General Requirements
1. WARNING – RISK OF EXPLOSIVE GASES.
2. CAUTION – WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES
GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS
REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING THE UNIT IN
THE VICINITY OF THE BATTERY, YOU READ THIS MANUAL AND FOLLOW THE
INSTRUCTIONS EXACTLY.
3. To reduce risk of battery explosion, follow these instructions and those published by battery
manufacturer and manufacturer of any unit you intend to use in vicinity of battery. Review
cautionary marking on these products and on engine.
4. This unit is intended to recharge batteries. The battery that is connected to this product is
only suitable if it complies with the given battery standard for that battery type and is provided
with a battery management system that will monitor and control the electrical and thermal
health of the battery during charging. When installing this device, the battery is to be verified
as in compliance with the applicable battery standard.
5. CAUTION – It's recommended to use battery packs provided by BLUETTI. Unverified,
damaged, or modified batteries may pose fire, explosion, or injury risks. If using a third-party
battery, follow its user manual for proper use and maintenance.
6. If the battery has no built-in protection features, install a properly rated fuse or DC circuit
breaker at the terminal.
7. Use short battery cables to minimize heat buildup and improve performance.
8. WARNING –Never reverse the battery's positive and negative terminals. Damage caused by
incorrect connection is not covered under warranty.
9. For marine use, pair this unit with Epad or any compatible voltage and current monitoring
device to track the charging process.
1.3.3 Personal Precautions
1. Someone should be within range of your voice or close enough to come to your aid when
you work near a lead-acid battery.
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or
eyes.
3. Wear complete eye protection and clothing protection. Avoid touching eyes while working
near battery.
4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters
eye, immediately flood eye with running cold water for at least 10 min and get medical
attention immediately.
5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
6. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or
short-circuit battery or other electrical part that may cause explosion.
7. Remove personal metal items such as rings, bracelets, necklaces, and watches when
working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high
enough to weld a ring or the like to metal, causing a severe burn.
8. NEVER charge a frozen battery.
9. If necessary to remove battery from vessel, always remove grounded terminal from battery
first. Make sure all accessories in the vessels are off, so as not to cause an arc.
10. Be sure area around battery is well ventilated.
11. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
12. Study all battery manufacturer's specific precautions such as removing or not removing
cell caps while charging and recommended rates of charge.
13. Add distilled water in each cell until battery acid reaches level specified by battery
manufacturer. This helps purge excessive gas from cells. Do not overfill. For a battery without
cell caps, carefully follow manufacturer's recharging instructions.
1.3.4 DC Connection Precautions
1. Connect and disconnect battery connections only after setting any device switches to off
position and removing AC cord from electric outlet or opening AC disconnect.
2. EXTERNAL CONNECTIONS TO CHARGER SHALL COMPLY WITH THE UNITED STATES
COAST GUARD ELECTRICAL REGULATIONS (33CFR183, SUB PART I).
1.4 Electrical Safety
1.4.1 General Requirements
1. Ensure all electrical connections comply with national/regional electrical standards.
2. User-provided cables should meet local legal requirements.
3. Use specialized insulated tools for electrical work.
1.4.2 Grounding Requirements
1. Before operating the unit, always confirm that it is properly grounded to reduce the risk of
electric shock.
2. Take care not to damage the grounding conductor.
3. Connections to unit should comply with all local codes and ordinances.
4. According to IEC62109-1 guidelines, if the ground wire is damaged or disconnected, connect
a protective ground wire to ensure safe use of the unit. Ensure the ground wire meets at least
one of these criteria:
a. Use a single-core outdoor copper cable with a conductor cross-sectional area of ≥10 mm² if
the PE terminal in the AC connector is not connected.
b. Use cables with the same wire diameter as the AC output cables, grounding both the PE
terminal in the AC connector and the chassis grounding screw separately.
1.4.3 Wiring Requirements
1. Keep cables at least 1.18in (30mm) away from heat sources and devices that emit heat, as
high temperatures can cause insulation to age or become damaged.
2. Bundle cables of similar types together to reduce electromagnetic interference. Keep
different types of cables at least 1.18in (30mm) apart and avoid twisting or crossing them.
3. All cable must be securely connected, well-insulated, and of suitable specifications.
4. Take necessary measures to protect cables when passing through pipes or holes.
5. in cold temperatures, severe impacts or vibrations can cause the plastic coating of cables to
become brittle and crack. To ensure safe installation:
a. Lay and install all cables at temperatures above 0°C (32°F). Handle cables with care, especially
when working in cold environments.
b. If cables have been stored in temperatures below 0°C (32°F), store them at room tempera-
ture for at least 24 hours before installation.
1.5 Handling Requirements
Table 1-1 Recommended Number of People Based on the Weight of Product
Weight
<18kg (39.7Ibs)
18kg-32kg (39.7lbs-70.5lbs)
32kg-55kg (70.5lbs-121.3lbs)
>55kg (121.3lbs)
Number of People
1
2
3
4 or a cart
JUST POWER ON 13
EN

2. What's in the Box
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
RV5
Power Hub
M8 Wood Screw ×8
Anchor x8
Drilling TemplateUser Manual & Warranty Card
The following accessories are not included. You can purchase optional accessories at
https://www.bluettipower.com/
B4810
LiFePO4 Battery Unit
Epanel
Smart Distribution Panel
Epad
Central Control Screen
Temperature Sensor Cable
PV100 FX
Solar Panel
Cable Kit
Edock
Battery Communication
Interface Box
Waterproof Cover
RV5
Power Hub
User Manual
V1.0
Important instructions
•
For optimal performance, update your unit to the latest firmware before first use.
•
See the appendix "Update Firmware via BLUETTI App" for guidance.
•
Read and understand this manual before use and keep it handy for future
reference.
EN
JUST POWER ON
14

3. Get to Know Your RV5
3.1 RV5 System
3.1.1 Introduction
1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
The RV5 System is a complete energy solution designed for RVs, boats, and off-grid power
setups. At its core, the RV5 5-in-1 power hub integrates seamlessly with the B4810 battery, Epad
control pad, Epanel distribution panel, and PV100 FX solar panel, providing efficient manage-
ment and monitoring of both DC and AC power.
The system is also compatible with BLUETTI battery packs like B1210, B1228, and the B300
series, as well as lead-acid and non-communication lithium batteries. With support for solar
panels with an open-circuit voltage of 12V-50V, the RV5 system delivers flexible, reliable power
wherever you go.
Battery Module (48V, 5120Wh)
Smart Distribution Panel: Supports up to 20 DC circuits
(6 app-controlled) and 8 AC circuits (4 app-controlled) for seamless
power distribution.
100W Flexible Solar Panel
Component
RV5
B4810
Epad
Epanel
PV100 FX
Note: The RV5 cannot be paralled.
Description
5-in-1 Power Hub: Integrated DC and AC power management
system featuring solar MPPT charging, vehicle charging, AC inverter,
battery charging, and a 48V DC-DC step-down module.
Energy Controller: Centralized system management with RV-C and
NEMA2000 protocol support, featuring liquid level and temperature
sensors, digital I/O, and multiple physical interfaces.
For instructions on other components, please refer to their respective user manuals.
JUST POWER ON 15
EN

1. Do not install, use, or maintain the unit in adverse weather conditions such as lightning, rain,
snow, and strong breezes (including handling, operating, plugging and unplugging signal
connections for outdoor facilities, working at heights, and outdoor installations).
2. Keep the unit away from heat sources or high temperatures, and do not expose it to direct
sunlight.
3. Do not clean the unit with water.
4. Regularly inspect the unit and its accessories for signs of damage or deterioration.
5. Use a tester to check for dangerous voltage before touching any conductor or terminal.
6. In the event of a fire, prioritize personal safety. If safe to do so, immediately disconnect power
and use a CO2, FM-200, or ABC dry powder fire extinguisher.
7. If a fire occurs, EVACUATE the affected area promptly. Activate the nearest FIRE ALARM
system and CONTACT local emergency services.
8. Do not store flammable or explosive materials near the unit.
9. Maintain a well-ventilated and spacious installation area.
10. Do not block or cover the unit’s openings and vents.
11. Use the unit only for its intended purpose and refrain from stacking objects on or near it
during storage or use.
12. Do not move the unit during operation, as vibrations and shocks from movement may
cause damage.
13. In case of malfunction, immediately power the unit off and contact BLUETTI support or your
local BLUETTI dealer if the manual does not adequately explain the issue.
14. Mount the unit securely on a metal bracket, wall, or stable platform to prevent it from falling.
Avoid placing it on inclined surfaces.
15. Keep the unit out of the reach of children and pets.
16. Do not install the unit where it may be exposed to water or submerged.
17. Do not touch the unit when it’s running, as the shell may become hot and pose a risk of
burns.
3.1.2 RV System Wiring
RV system wiring
Chassis
GND
Chassis
GND
AC Inputs
B4810
RV5
PV100 FX
AC Appliance
DC Appliance
Epanel
Epad
Starter
battery
Chassis
GND
Chassis
GND
AC Inputs
B4810
RV5
PV100 FX
AC Appliance
DC Appliance
Epanel
Epad
Starter
battery
EN
JUST POWER ON
16

3.1.3 Off-grid System Wiring
Off-grid system wiring
AC Inputs
B4810
RV5
PV100 FX
PV100 FX
AC Appliance
DC Appliance
Epanel
Epad
JUST POWER ON 17
EN

3.2 RV5 Power Hub
3.2.1 Dimensions
EN
JUST POWER ON
18

3.2.2 Overview
13 14 15
7
9
10
11
12
2
1
3
5
4
6
8
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
DC Power Button
Power Button
AC Power Button
LCD Display
Grounding Terminal*
EMS Communication Port
Epanel Communication Port
12V/24V DC Output
PV1 Input
PV2 Input
Battery Temperature Sampling Port
Battery Communication Port
Battery Terminal
AC Input (N/L1/L2/G)
AC Output (L/N/G)
* Used for grounding when powering certain appliances.
JUST POWER ON 19
EN

1 2 3
5
4
6 7
8
9
20
19
3.2.3 LCD Display
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
Fan
PV Input
Bluetooth Connection
WiFi Connection
State of Charge (SoC)
Capacity Progress;
Turbo Charging
Low Battery Alert
Output Power
AC Output Frequency
AC Input
DC Output
AC Output
Remaining Time
Charge / Discharge Status
High Temperature
Overload
Over-current
System Fault
Charge / Discharge Progress
Input Power
⑪
⑫
⑬
⑭
⑮
⑯
⑰
⑱
⑲
⑳
EN
JUST POWER ON
20

4. Set up Your RV5
4.1 Required Tools
Danger
Warning
Caution
• Do not install the unit below pipes, windows, or in areas prone to
water leaks and accumulation.
• Disconnect all electrical connections from the unit before installation.
• Do not block ventilation openings or heat dissipation pathways.
• Restricted airflow can lead to overheating and pose a fire risk.
• When moving the unit, be mindful of its weight and balance. Take care
to avoid tipping or dropping it, as that could result in damage to the unit
or personal injury.
• Do not lift heavy loads without assistance.
#2 Screwdriver Multimeter Allen Wrench (6mm)
Note: The listed tools are required for installing the RV5. Please prepare any additional tools
and accessories as needed.
JUST POWER ON 21
EN

4.2 Mount the RV5
4.2.1 Space Requirements
Make sure there's at least 8in (20cm) of space around the unit for cables and airflow as shown
below.
Space requirements
Cool air
Hot air
≥200mm/7.87in≥200mm/7.87in
≥200mm/7.87in≥200mm/7.87in
If the RV5 operates in a high-temperature environment without proper ventilation, its charging
and discharging power will decrease. To maintain performance, ensure the RV5 has adequate
ventilation.
Note: The data shown is based on lab tests under controlled conditions and is for reference
only. Actual results may vary based on the environment.
Ambient
Temperature
131°F (55°C)
95°F (35°C)
Charging Power Discharging Power
AC ACDC 12VDC 24VDC
5,000W 3,000W 4,000W 1,000W 1,620W
5,000W 3,600W 5,000W 1,360W 1,620W
EN
JUST POWER ON
22

1 2
4.2.2 Mounting Instructions
Danger
•
Before drilling, check for nearby water pipes or electrical cables to avoid
any hazards.
• The included M8 screws and anchors are for wooden and cement walls.
Use suitable screws for other surfaces to ensure a secure installation.
RV5 can be installed in two ways: wall-mounted or floor-mounted, using different screw
holes shown below.
① Round holes: For floor mounting in RVs, boats, or other vibration-prone condition.
② Keyhole slots: For wall mounting in stable places like cabins. Not for use in moving
vehicles.
JUST POWER ON 23
EN

A. Wall-Mounted Installation
Step 1: Select a suitable location. Tape the drilling template to the wall and mark the keyholes.
Step 2: Use a #2 screwdriver to fasten the M8 screws into the keyhole slots.
Step 3: Hang the RV5 on the screws.
Step 4: Ensure all screws are firmly tightened.
1
390mm/15.35in
481mm/18.94in
476mm/18.74in
330mm/12.99in
EN
JUST POWER ON
24

B. Floor-Mounted Installation
Step 1: Select a suitable location. Tape the drilling template to the wall and mark the round
holes.
Step 2: For cement walls, drill holes at the marked points and insert the anchors.
Step 3: Secure the unit by driving M8 screws into the anchor.
For other wall materials, drive the appropriate screws into the wall. It's recommended to have 2
people for this.
Step 4: Ensure all screws are firmly tightened.
Floor-mounted installation
2
390mm/15.35in
481mm/18.94in
476mm/18.74in
330mm/12.99in
JUST POWER ON 25
EN

4.2.3 Install the Waterproof Cover
In rainy areas, you can install the optional waterproof cover above the fan vent to prevent ceiling
drips.
Waterproof cover installation
EN
JUST POWER ON
26

4.3 Wire and Fuse Specifications
For best performance and safety, use the shortest and thickest cables possible. Undersized
cables can overheat and cause a fire risk. If you're unsure about the right cable size, contact
BLUETTI support or consult a professional.
Connection Image
To 48V Battery
AC Input
Cable
AC Output
Cable
Vehicle
Charging
Cable
DC Output
Cable
RJ45 Ethernet
Cable
Wire Gauge Qty.
Recommended
Fuse
Note
Solar Charging
Cable
6-8 AWG
(10-6mm²)
6-8 AWG
(10-6mm²)
6-8 AWG
(10-6mm²)
2-4 AWG
(25-16 mm²)
/
/
/
/
/
0-4 AWG
(50-16mm²)
6-8 AWG
(10-6mm²)
2
(1 red, 1 black)
2
(1 red, 1 black)
3 (for 3-pin) /
4(for 4-pin)
*
2
(1 red, 1 black)
2
(1 red, 1 black)
~200A
(Use a fuse rated
at ~1.5x current)
Built-in fuse
with the AC
input port
~75A
No fuse needed
with the B4810
battery. Choose
the wire gauge
based on load
power.
Match the wire
gauge to your AC
input socket
specifications.
A fuse is required
for vehicle charging.
Required for
BLUETTI devices
communicating
with RV5. Use the
shortest cable
possible.
3
JUST POWER ON 27
EN

4.4 Wiring Overview
Step 1
Make sure the unit is
intact and securely
mounted.
Step 2
Remove the two
external screws and
take off the first cover.
Keep the screws and
set the cover aside.
Step 3
Remove the second
panel (no screws).
Step 4
Connect the cables as
shown and secure
them.
Step 5
Reattach the second
panel.
EN
JUST POWER ON
28

Press and hold
for 2 seconds.
Step6
Connect the cables as
shown and secure
them.
Step7
Connect the commu
nication cables.
Step8
Secure the first cover
with all screws.
Step9
Connect the ground
ing cable.
Step10
Power on the unit and
complete the initial
setup in the BLUETTI
app.
JUST POWER ON 29
EN

4.5 AC Input Wiring
The RV5 supports both single-phase 120V input and 208V/240V input (EV charging mode).
Below is the power flow for each mode:
Bypass Mode (120V Input)
EV Charging Mode (208V/240V Input)
EN
JUST POWER ON
30

4.5.1 Shore Power
Connect the AC input cable from the RV5 to a 120V shore power inlet.
Note: A 3-pin RV adapter is required.
4.5.2 Generator
Connect the RV5 to a gasoline, propane, or diesel generator using the AC charging cable.
The charging stops automatically when the battery is fully charged.
Note: This product requires a 3-pin RV inlet (not included).
Single-phase 120VAC generator charging
Single-phase 120VAC shore power charging
JUST POWER ON 31
EN
JUST POWER ON
EN

If using the Epad, connect its DO port to the generator's start signal port for black start. For more
details, refer to the Epad User Manual.
Make sure the generator delivers a pure sine wave output with matching
voltage and frequency.
Ensure the generator's output power exceeds the RV5's charging
requirements.
It's recommended to enable the Grid Self-Adaption mode when charging
the RV5 with a generator.
Attention
• Enable EV charging in the app before use. Disconnect the AC loads
during charging, as bypass output is not available while charging.
• Use a 4-pin RV inlet for permanent wiring.
Attention
4.5.3 EV Charging Station
Connect the RV5 to an SAE J1772-compatible EV charging station as shown below. The
charging stops automatically when fully charged.
Single-phase 208V/240V EV charging
RV Power Inlets
(Not included)
EV charger adapter
(Not included)
EN
JUST POWER ON
32

4.6 AC Output Wiring
The RV5 supports AC output of up to 5,000W and 42A for single-phase 120V AC appliances. In
bypass mode, it can handle up to 6,000W and 50A.
For optimal performance, it's recommended to use the Epanel to manage the AC output
current. For details, refer to the Epanel User Manual.
AC output wiring with Epanel
Step 1: Prepare three power cables (bare ends on both sides) and one RJ45 Ethernet cable.
Then, unscrew the AC output seal cover.
Step 2: Insert the bare ends of the power cables into the corresponding terminals (L/N/G), and
connect the other ends to the Epanel. Make sure there are no exposed cables.
Step 3: Ensure that all connections are secure.
Ethernet Cable
JUST POWER ON 33
EN

Attention
When using lead-acid or non-communication lithium batteries, ensure
the total voltage is 48V.
Warning
Attention
•
Before servicing any connected devices, physically disconnect them
from the RV5.
• If the AC output terminals are not in use, keep the seal covers in place.
• For a permanently wired system, install a ground-fault circuit
interrupter (GFCI) at the AC output to protect all branch circuits. We
recommend using the Blue Sea Systems GFCI breaker (PN3093).
• Use an overcurrent protection device for the branch circuit. It's
recommended to use it with the Epanel.
4.7 Battery Wiring
The RV5 supports 48V battery systems and is compatible with various battery types. To
protect your battery, the RV5 applies different current-limiting strategies, with a maximum
current of 150A.
Battery Model
B4810
B1210/B1228
B300
Series
B300
B300K
B300S
Lead-Acid Battery
Non-communication
Lithium Battery
1S1P
1SnP (n = 24P Max. )
4S1P
4SnP (n = 24P Max.)
1SnP (n = 4P Max.)
1SnP (n = 6P Max.)
48V
48V
1C (A)
150A
1C (A)
150A
75A
75A
75A
1C (A)
1C (A)
For setups with more than
8 batteries, Edocks are
required. See Appendix 1
for wiring details.
See Appendix 2 for wiring
details.
Necessary adapter cables
needed. See Appendix 3
for wiring details.
For details, refer to the
relevant user manual.
Configuration Current Limit Notes
EN
JUST POWER ON
34

The RV5 battery terminal doesn't have reverse polarity protection. Ensure
the battery is connected with the correct polarity, as indicated on the
port. If you're unsure, use a multimeter or consult a qualified electrician.
The B4810 and B1210 battery packs have reverse polarity protection. If
the polarity is incorrect, an E091 error will appear and the power
button indicator will flash. For more details, refer to the battery pack's
user manual.
4.7.1 Wiring Instructions
To check the battery polarity and voltage with a multimeter:
Step 1: Set the multimeter to DC voltage mode.
Step 2: Connect the positive lead to the battery's positive terminal (red) and the negative
lead to the negative terminal (black).
Battery polarity check
Step 3: Check the reading:
• 48V to 56V: The polarity and voltage are correct. You can continue wiring.
• Negative reading: Reverse the connections.
• Outside 48V to 56V: Verify the battery’s condition and check the wiring.
4.7.2 B4810 Battery
To achieve full power output, it is recommended to pair the RV5 with two B4810 battery
packs, providing a total capacity of 10kWh. When used with a single B4810, the total load
power is approximately 4320W.
An Ethernet cable is also required for connection with the B4810. Refer to chapter 4.11 for
details.
Attention
Warning
JUST POWER ON 35
EN

The RV5 supports stacking up to 4 B4810 units. Stacking more packs
could damage the battery casing and pose a safety risk.
• Power off the battery before connecting.
• Do not disconnect the battery while it's operating.
Danger
Warning
Attention
For optimal performance and safety, it is recommended to use the
temperature sensor cable. Attach it to the battery surface to help the RV5
adjust its operation based on temperature, ensuring more accurate and safe
charging.
When connecting lead-acid batteries, ensure they are of the same brand
and voltage, as lead-acid batteries don’t have a balancing feature. Do not
mix different capacities or combine new and used batteries.
RV5 + 2* B4810 Wiring
Step 1: Prepare two power cables (bare ends on both sides—red for positive, black for negative )
and the pre-assembled B4810 battery packs based your load requirements.
Step 2: Connect the black power cable from the RV5's BAT- port to the B4810's main negative
terminal.
Step 3: Connect the red power cable from the RV5's BAT+ port to the B4810's main positive
terminal.
Step 4: Ensure that all connections are secure.
4.7.3 Lead-acid Batteries & Non-communication Lithium Batteries
When using a lead-acid battery for the first time, please discharge the battery pack to 0%
and then fill it up to 100% Soc.
EN
JUST POWER ON
36

The maximum charging current for lead-acid batteries is set at 0.2C, with the constant
charging voltage adjusted for temperature. Non-communication lithium batteries have a
maximum charging current of 0.5C.
Since lead-acid batteries cannot release their full capacity under high-rate discharge
conditions, and it is easy to accelerate the corrosion of the lead-acid battery plates and
capacity decay, please try to avoid frequent or continuous high-rate discharge. It is recom
mended to reasonably configure the lead-acid battery capacity according to your actual
needs, see the table below:
RV5 + lead-acid batteries wiring (4S1P)
0.1C load power
(AC+DC) can
carry load for a
long time
Maximum power
allowed (estimated
based on 90%
efficiency) can be
short-term loaded
Recommended
total lead-acid
battery capacity
Recommended
series-parallel
configuration
(taking 12V100Ah
lead-acid battery
as an example)
Recommended
wire diame-
ter(Battery to RV5)
0AWG or 50mm²
2AWG or 25mm²
2AWG or 25mm²
2AWG or 25mm²
4AWG or 16mm²
4S15P
4S10P
4S5P
4S2P
4S1P
1500Ah
1000Ah
500Ah
200Ah
100Ah
6600W
6600W
6600W
6600W
4320W
6600W
4320W
2100W
900W
450W
JUST POWER ON 37
EN

Step 1: Wire the 12V lead-acid battery packs in series and parallel to achieve a total
voltage of 48V, ensuring correct polarity.
Step 2: Prepare one red and one black power cable (bare ends to OT terminals), and
install the appropriate fuse on the battery’s positive terminal.
Step 3: Connect the black power cable’s bare end to the RV5’s BAT- port and the OT
terminal to the battery’s negative terminal.
Step 4: Connect the red power cable’s bare end to the RV5’s BAT+ port and the OT
terminal to the battery positive terminal.
Step 5: Insert the temperature sensor cable into the battery’s temperature sampling
port and attach the other end to the battery surface.
Step 6: Ensure that all connections are secure.
Danger
Attention
•
Make sure your solar panel(s) meet the following requirements:
VOC: 12V-50V Current: 50A Max. Power: 1,800W Max.
• Do not ground the solar panels' positive and negative terminals.
Warning
Attention
When using lead-acid batteries or non-BLUETTI battery packs:
1. Ensure correct wiring polarity. Damage from reversed polarity is not
covered under warranty.
2. Use a properly rated overcurrent protection device, such as a fuse or
DC circuit breaker.
When using a lead-acid battery, turning the device on or off must be
done via the power switch button on RV5 (or Epad).
Please note that due to the lower voltage of lead-acid batteries under
high discharge rates, overcurrent protection may be triggered,
making it impossible to operate at full power.
4.8 DC Input Wiring
4.8.1 Solar Panel
Do not use the vehicle's cigarette lighter to charge.
EN
JUST POWER ON
38

The RV5 comes with two DC input ports, PV1 and PV2. Each supports up to 50A and
1,800W of solar charging power, totaling 3,600W. The charging time may vary based on
weather conditions, sunlight intensity, panel orientation, and other variables.
Step 1: Prepare two power cables (bare ends to MC4 connectors-red for positive, black for
negative) and the connected PV100 FX solar array. Make sure the PV circuit breaker is off.
Step 2: Insert the bare ends into the PV1+/PV1- ports, ensuring no exposed cables.
Step 3: Connect the MC4 ends to the PV100 FX's MC4 connectors.
Step 4: Ensure that all connections are secure.
For the recommended setup, see the table below. For more details, refer to the PV100 FX User
Manual.
RV5+PV100 FX wiring(6 pcs)
Note: The function of PV2 port can be set through the APP
600W
1,000W
1,600W
PV100 FX Panels
6
10
16
Solar Charging Cables
5
9
15
Input Power
JUST POWER ON 39
EN
JUST POWER ON
EN

For safety, always install a fuse or other overcurrent protection on the
starter battery ports. Damage caused by missing protection is not covered
under warranty.
If you're unsure about the required fuse rating, consider using the optional
cable kit provided by BLUETTI or contacting BLUETTI support for
assistance.
Attention
4.8.2 Vehicle (12V/24V)
Connect the RV5 to your vehicle's starter battery via the PV2 ports. The required connec-
tion cable and fuse are included in the optional cable kit. Once fully charged, the RV5 will
stop charging automatically.
Charging power may vary based on your vehicle's output and environmental conditions.
To prevent battery drain, set the charging current in the app according to your
alternator's capacity.
Vehicle charging wiring
Step 1: Prepare two 6 AWG power cables, (bare ends to OT terminals—red for positive,
black for negative) and a properly rated overcurrent protection device such as a fuse.
Step 2: Insert the bare ends into the PV2+/PV2- ports, ensuring no exposed cables.
Step 3: Connect the OT terminal of the black (negative) cable to the starter battery's
negative terminal.
Step 4: Install a fuse on the starter battery's positive terminal.
Step 5: Connect the OT terminal of the red (positive) cable to the other end of the fuse.
Step 6: Ensure that all connections are secure.
EN
JUST POWER ON
EN
JUST POWER ON
40

Danger
Attention
Do not connect battery packs to the RV5's DC output ports, as battery
charging is not supported.
To change the DC output voltage, turn off the DC output and wait
for 1 minute before adjusting the settings.
4.9 DC Output Wiring
The RV5 supports both 12V and 24V DC output. Select the appropriate voltage based on
your battery system requirements and configure the settings before first use. For setup
details, refer to the App User Manual.
Supported Output:
• 12V: 100A, up to 1,360W
•
24V: 60A, up to 1,620W
It's highly recommended to use the Epanel smart distribution panel along with an
Ethernet cable to manage the DC output. Refer to chapter 4.11 for details.
DC output wiring with Epanel
Step 1: Prepare two 2 AWG power cables (bare ends on both sides—red for positive, black for
negative).
Step 2: Insert the two ends of the cables into the DC OUT+/DC OUT- ports, and the other ends
into the Epanel's DC IN+/DC IN- ports.
Step 3: Ensure all cables are fully secured with no exposed wires.
To power a leveling system, connect it to the DC busbar before any distribution device. This
setup supports high-current surges up to 100A at 12V.
JUST POWER ON 41
EN

4.10 Grounding
For temporary AC input connections, such as in an RV or marine setup, the unit must be
grounded to the vehicle chassis or the boat's hull or grounding plate. Follow the instruc-
tions below for proper installation:
Step 1: Prepare a grounding cable (recommended to use 10mm2 yellow-green outdoor
cable), RNB14-6S OT terminal, and M6 screws (pre-installed on the unit).
Step 2: Strip the insulation layer of the grounding cable with a cable stripper to a proper
length. Insert the exposed core wires into the RNB14-6S OT terminal and crimp them
with a crimp.
Step 3: Fix the OT terminal with M6 screws at the position shown in the figure below.
Securely ground the other end of the cable in the favorite way.
Recommended torque: 2 Nm.
Grounding cable assembly
L2 is 3 mm (0.12 in) longer than L1.
L2=L1+3mm
L1
L3=2 mm/0.079 in
L4=1 mm/0.039 in
Visible wire
Wire even or bulge up to 1 mm/0.04 in
Terminal block
Wire
EN
JUST POWER ON
42

Danger
Follow local regulations for proper grounding. Incorrect grounding
may pose a risk of electric shock. If you're uncertain, consult a
qualified electrician.
Grounding cable installation
The RV5 also supports an off-grid TT earthing system, i.e. neutral-ground bonding. For details,
refer to chapter 5.3.4.
4.11 CAN Communication Wiring & Configuration
To ensure seamless communication among your BLUETTI devices, connect and configure
them as shown below. Incorrect setup may lead to communication issues.
Note: Do not plug the battery communication cable into the Epad or Epanel ports.
If you're unsure about your setup, contact BLUETTI support for assistance.
Chassis ground
JUST POWER ON 43
EN

OFF
ON
OFF
ON
OFF
ON
OFF
ON
RV5 + B4810 + Epanel + Epad
RV5 + B4810 + Epad
RV5 + B4810 + Epanel
EN
JUST POWER ON
44

Before use, double-check that all connections are correct and secure.
Once confirmed, cover both the inner and outer panels. Keep the
casing intact during operation, and do not open any covers to avoid
exposing the ports, leading to electric shock.
Attention
5. Use Your RV5
5.1 Power On/Off
A. Power On
Press and hold the power button for 2 seconds while it's off or in sleep mode. The lit button
indicates that the RV5 is on. For initial use, complete the setup in the app.
If you're using BLUETTI B4810, B1210, B1228, or B300 series batteries, you can also power on
the unit via the app.
B. Sleep Mode
JUST POWER ON 45
EN

Attention
• The sleep mode is disabled when AC input is detected. Any AC power
source will automatically wake the unit.
• In sleep mode, the unit maintains low-power solar charging. All ports
remain live—avoid contact to prevent electric shock.
• This mode can only be enabled via the app.
Attention
•
When the RV5 is on (not in sleep mode), press any button to activate the
display.
• Startup time may vary depending on the connected battery type.
The RV5 features a sleep mode to extend battery life. In this mode, it charges the battery with
up to 100W solar power while keeping the display off. When connected to a network, the RV5
also supports remote wake-up.
Enter the mode: With the unit on, press and hold the power button for about 2 seconds until
the display turns off. For app instructions, refer to the App User Manual.
Exit the mode: Press and hold the power button for about 2 seconds until the display turns
back on.
C. Power Off
Press and hold the power button for 5 seconds until "OFF" appears on the display (③). The
display will first enter sleep mode (①), then turn off (②).
Note: The unit cannot be powered off while connected to solar or AC input. To shut it down,
disconnect the solar and AC sources physically or turn off the circuit breaker first.
① 3s ② 1.5s ③ 8s
EN
JUST POWER ON
46

Attention
•
Configure the ports in the app before first use.
5.2 Initial Setup
Initial app configuration
Note: For detailed configurations, refer to the App User Manual.
5.3 Configure Your RV5
5.3.1 Charging Mode
The RV5 offers three charging modes: Standard, Turbo, and Silent. You can set Turbo and
Standard modes directly on the unit, or use the app to set any of the three modes.
Charging stops automatically once the battery is fully charged, and the charging power
is limited by the grid's maximum input current and battery capacity. By default, the unit
charges in Standard mode.
RV5 SetupSTART
Step 1
Step 2Step 3
Step 5Step 4
FINISH
Battery
configuration
PV2
configuration
DC output
voltage setup
Max. grid input
current setup
Standard
1,440W Max. 2,000W Max. 2,000W Max.
2.5 hours
Turbo
5,000W Max. 3,600W Max. 8,600W Max.
Silent 1,200W Max. 1,200W Max. 1,200W Max. 4 hours 7.5 hours
80% charge
in 45 mins;
full charge
in 1.5 hours
80% charge
in 50 mins;
full charge
in 2 hours
4.5 hours
JUST POWER ON 47
ENEN
(for two
B4810 Units)
(for Single
B4810 Units)
Mode
Charging Power
AC PV AC + PV
Charging Time

5.3.2 Adjust Grid Input Current
The default maximum grid input current is 12A. Use the app to increase it up to 50A.
For safety, set the maximum input current to 80% of your outlet's rated capacity.
Alternatively, consult an electrician to confirm that the outlet can handle the current.
5.3.3 Grid Self-Adaption Mode
When connecting with a generator or unstable grid power, or if consumption power
exceeds charging power, enable this mode in the app. The RV5 automatically adjusts to
handle power fluctuations, protecting the unit and connected devices from potential
issues due to variations in power quality.
You can also adjust the input voltage limits in the app's advanced settings to match
your power needs. For details, please refer to the App User Manual.
5.3.4 Neutral-Ground Bonding
The RV5 has a built-in neutral-ground bonding relay, which automatically manages the
neutral-to-ground connection based on the inverter's operating mode when enabled in
the app's Advanced Settings.
• When the inverter is connected to AC power:
The AC input relay closes, and the neutral-ground bonding relay opens. The
neutral-to-ground connection is provided by the AC source, allowing RCD, RCCB, RCBO,
or GFCI protection devices to function properly.
• When there is no AC input:
The AC input relay opens, and the neutral-ground bonding relay closes, internally
bonding neutral to ground. At this time, the RCD, RCCB, RCBO, or GFCI also are able to
function properly.
For details, refer to the App User Manual.
Follow local regulations for proper grounding. Incorrect grounding
may pose a risk of electric shock. If you're uncertain, consult a
qualified electrician.
5.4 Button Control
①Enter the Settings Mode: Press and hold the AC and DC power buttons simultaneously.
② On the P01 page:
• Adjust settings: Press the DC power button to navigate through the items, and press the
AC power button to adjust.
• View information: Long press the DC power button to view the unit's SN, and press it
again to navigate through information. When on page, long press the AC power
button to clear the history.
③ Exit the Settings Mode: Press and hold both the AC and DC power buttons again.
Danger
EN
JUST POWER ON
48
EN
JUST POWER ON

6. Maintenance and Care
Always power off the system before performing maintenance tasks such as cleaning,
checking connections, and verifying grounding. The RV5 requires regular maintenance,
including:
• Inspect and clean the fan, fan guard, and heat sink if dust or blockages are present.
• Ensure that the fan operates smoothly without any abnormal noise.
• Check and tighten input and output cable connections using a torque wrench. For
frequent mobile use, inspect the connections at least once a month.
7. Specifications
System Voltage
Max. Input/Output Current
Rated Input Voltage
Rated Input Current
Rated Input Current
Rated Input Voltage
Input Frequency
Uninterruptible Power Supply (UPS)
Bypass
Charging Power
Rated Output Voltage
Rated Output Current
Rated Output Frequency
Rated Output Power
Battery Terminal
Model RV5
48V
150A
AC Input
120V
42A
208V/240V
22A
( EV does not support bypass mode. )
60Hz ±3Hz
Switchover time ≤20ms
50A Max.
5,000W Max.
AC Output
120V
42A
60Hz
5,000W
JUST POWER ON 49
EN
[1]
[2]
EV Input (L1/L2/G)
Standard AC
Input (N/L1/G)

[1]Compatible with B4810, B1210, B300 series, and other lithium and lead-acid batteries.
[2]Power limits may vary based on ambient temperature and the connected battery capacity.
PV1/PV2
(Solar)
PV1/PV2 Input
DC Output
Max. Input Power
1,800W
Input Voltage
12V to 50V
Max. Input Current 50A
PV2 (Vehicle
Charging)
PV2 (Vehicle
Charging)
Max. Input Power
600W (12V)
1,200W (24V)
Input Voltage
12V to 14.4V (12V battery)
24V to 28.8V (24V battery)
Max. Input Current 50A
Rated Output Voltage
Rated Output Current
Rated Output Power
12V/24V
100A (12V)
60A (24V)
1,360W (12V)
1,620W (24V)
Approx. 30.86lbs (14kg)
17.72 × 19.69 × 6.30in (450 × 500 × 159.9mm)
-4°F to 113°F (-20°C to 45°C)
113°F to 131°F (45°C to 55°C)*
Load derating
under over-temperature conditions.
-4°F to 131°F (-20°C to 55°C)
95% Max.
UL458
Weight
Dimensions
Storage Temperature
Working altitude ≤2000m
Operating Humidity
Certification
General
EN
JUST POWER ON
50
Operating Temperature

8. Troubleshooting
On the Error Code page, the and error code appears simultaneously on the display. See
the table below for guidance.
Error Code SolutionsDescription
E001
E002
E003
E026
E033
E034
E036
E037
E039
E040
E065
E067
E068
Inverter overload
Inverter overtemperature
protection, AC output off
Inverter short circuit
Unit overload
PV1 overvoltage
PV2 overvoltage
PV1 overcurrent
PV2 overcurrent
PV1 overtemperature
PV2 overtemperature
DC output short circuit
DC output overcurrent
DC output
overtemperature
• Check device power usage.
• Reduce load if too high.
• Wait 10 mins for the unit to cool down.
• Turn on the AC output again.
• Check device for short circuits.
• Disconnect the fault and fix.
• Verify the battery pack is properly
connected.
• Check if the power usage exceeds the
battery terminal’s limit.
• Make sure the PV1 input voltage is within
12V-50V.
• Make sure the PV2 input voltage is within
12V-50V.
• Make sure to use solar panel(s) as the
input source.
• If the voltage from the panels is higher
than the battery voltage, just wait until
the battery voltage rises above the panel
voltage. The system will recover
automatically.
• Wait 10 mins for the unit to cool down.
• Re-enable the PV1 input.
• Wait 10 mins for the unit to cool down.
• Re-enable the PV2 input.
• Disconnect DC loads, and restart the RV5.
• Disconnect DC loads, and restart the RV5.
• Wait 10 mins for the unit to cool down.
JUST POWER ON 51
EN

• Please check if EV mode is enabled when
EV charging is connected.
• Check if the battery pack communication
cable is loose or detached. Reconfirm the
number of battery packs in the system.
E070
E081
E085
E086
E087
E088
Others
/
Battery overvoltage
Charging temperature
too high
Charging temperature
too low
Discharging temperature
too high
Discharging temperature
too low
Battery System
communication
failure
• Ensure the Ethernet cable is properly
connected to the battery pack.
• If using a non-communication battery,
make sure it's set accordingly.
E075
BMS system failure
• Please handle according to the attached
battery pack fault code.
• Disconnect the input source.
• Place the battery in an ambient
temperature range of -4°F to 131°F
(-20°C to 55°C) .
E113
E114
E115
E116
E117
E121
Grid overvoltage
Grid undervoltage
Grid overfrequency
Grid underfrequency
Grid oscillation
PV configuration error
• Verify home grid voltage.
• Contact utility company or enable the
Grid Self-adaption mode if necessary.
• Verify home grid voltage.
• Contact utility company or enable the
Grid Self-adaption mode if necessary.
• Verify home grid frequency.
• Contact utility company if necessary.
• Verify home grid frequency.
• Contact utility company if necessary.
• Verify the grid's stability.
• Enable the Grid Self-adaption mode if
necessary.
• Please check if EV mode is enabled when
EV charging is connected.
• Check if the PV2 port is configured
correctly.
E129
Battery pack
communication
failure (Pack)
EN
JUST POWER ON
52

FAQs (Frequently Asked Questions)
Q1: Can I use third-party solar panels with this unit?
A: Yes, you can use third-party solar panels with open circuit voltage of 12V-50V. Avoid
mixing different types of solar panels.
Q2: Does it support charging and discharging at the same time?
A: Yes, RV5 supports pass-through charging as long as EV charging is not activated.
Q3: Why is the charging power often too low?
A: The built-in BMS adjusts the charging power based on battery temperature and SoC
to protect the battery and extend its life.
Q4: Why can't I run the load at full power with a lead-acid battery?
A: The RV5 limits the current from lead-acid batteries to protect the terminals and
cables. If the battery voltage drops too low, this can prevent the RV5 from providing full
power to the load.
JUST POWER ON 53
EN

Appendix 1
B4810 + Edock connection
Choose the appropriate busbar pair size based on the number of connected battery packs,
ensuring a minimum current capacity of 150A.
For more than two B4810 units, we recommend using a busbar pair to keep cable lengths
consistent for each connection to the RV5.
EN
JUST POWER ON
54

Appendix 2
B1210 + Edock connection
JUST POWER ON 55
EN
JUST POWER ON
EN

Appendix 3
B300K connection
Note: The RV5 supports connecting up to four B300 units.
EN
JUST POWER ON
56
EN
JUST POWER ON

• FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
IMPORTANT NOTE:
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum
distance of 20cm between the radiator and your body.
Compliance
JUST POWER ON 57
EN

EN
JUST POWER ON
58
• IC Caution
This device contains licence-exempt transmitter(s) / receiver(s) that comply with
Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause
undesired operation of the device.
RF exposure statement: The equipment complies with IC Radiation exposure limits set
forth for uncontrolled environments. This equipment should be installed and operated
with a minimum distance of 20cm between the radiator and your body.
CAN ICES (B)/NMB(B) (Canada)
This Class B digital apparatus complies with Canadian ICES-003.

@ BLUETTI Official
@bluetti.inc @bluetti.inc@ bluetti_inc
Need Help? We're here for you!
Visit Us
SHENZHEN POWEROAK NEWENER CO., LTD.
19F, Block A, Kaidaer Bldg., No. 168 Tong Sha Rd, Shenzhen, China
BLUETTI Power Inc.
6185 S Valley View Blvd, Ste D, Las Vegas, NV 89118, US
Customer Service(US)
+1 800-200-2980 (Mon-Sun 9:00-17:00) service@bluettipower.com
Customer Service(DE)
+49 8006273016 (Monday to Friday 9:00 - 17:00) service@bluettipower.com
Customer Service(UK)
+44 8000472906 (Monday to Friday 9:00 - 17:00) service@bluettipower.com
Company: POWEROAK ENERGY UK CO.,LTD
Address: Unit 2 NorthGate, Bolsover Business Park, Woodhouse Lane
Chesterfield England, S44 6BD
Company: POWEROAK GmbH
Address: Lise-Meitner-Str. 14 28816 Stuhr Germany
JUST POWER ON 59
EN

EN
JUST POWER ON
60

À propos le Manuel
Symbole Conventions
Cemanuel utiliser s le suivant symboles à souligner important information :
But
Ce manuel utilisateur décrit le installation, électrique connexion, mise en service, entretien et
dépannage de RV5. S'il te plaît lire et comprendre tous instructions dans ce manuel avant
utiliser.
Danger
Avertissement
Prudence
Attention
Note
Il indique un dangereux situation lequel, si pas évité, volonté résultat
dans la mort ou sérieux blessure.
Il indique un dangereux situation lequel, si pas évité, pourrait résultat
dans la mort ou sérieux blessure.
Il indique un dangereux situation lequel, si pas évité, pourrait résultat
dans mineure ou modéré blessure.
Il contient important supplémentaire information comme Bien comme
utile conseils pour sûr, efficace et sans tracas opération de le RV5.
Il indique une situation potentiellement dangereuse qui, si elle n’est
pas évitée, pourrait cause substantiel dommage à propriété et le
environnement.
JUST POWER ON 61
FR

1. Sécurité Instructions
IMPORTANT SÉCURITÉ INSTRUCTIONS
FR
JUST POWER ON
62
SAUVEGARDER CES INSTRUCTIONS – Ce manuel contient important sécurité et en
fonctionnement instructions pour RV5.
1.1 Général Instructions
1.1.1 Déclaration
Avant installation, en fonctionnement, ou maintenir ce unité, s'il te plaît lire ce manuel
soigneusement et suivre tous sécurité précautions indiqué sur le unité et dans ce manuel.
Regarder pour et suivre tous "Note", "Attention", "Prudence", "Avertissement", et "Danger"
déclarations dans ce manuel. Le sécurité lignes directrices fourni ici faire pas couverture tous
possible sécurité considérer Veuillez respecter toutes les normes internationales, nationales ou
régionales pertinentes, ainsi que industrie pratiques. Notre entreprise devoir pas être respons-
able pour dégâts résultant depuis non-conformité ance avec ces sécurité exigences ou
normes.
Pour problèmes ou opérations pas couvert dans ce manuel, s'il te plaît contact BLUETTI
soutien, autre Nous ne sommes pas responsables des dommages ou blessures causés par des
opérations non autorisées. Toujours considérer le réel sur place conditions quand en utilisant le
unité. Utiliser il seulement dans environnements que rencontrer le exigences décrit dans ce
manuel. Échec à faire donc peut cause équipement dysfonctionnements ou dommage,
lequel sont pas couvert par le garantie. Notre entreprise est pas responsable pour n'importe
lequel blessures ou propriété dommage causé par incorrect utiliser.
Ainsi, pour approprié installation et utiliser de ce unité, c'est crucial à adhérer à le suivant guide
lignes:
1. Toujours fonctionner ou magasin le unité dans le conditions spécifié dans ce manuel.
2. PRUDENCE – À réduire risque de blessure, charge seulement LiFePO4 ou plomb-acide piles
taper rechargeable piles . Autre types de piles peut éclatement causant personnel blessure et
dommage.
3. Faire pas exposer le unité à pluie ou neige.
4. Utiliser de un pièce jointe pas recommandé ou vendu par nous peut résultat dans un risque
de feu, électrique choc, ou blessure à personnes.
5. Faire pas démonter le RV5; prendre il à un qualifié militaire quand service ou réparation est
requis. Incorrect remontage peut résultat dans un risque de électrique choc ou feu.
6. À réduire risque de électrique choc, débrancher le RV5 depuis le sortie avant tenter n'importe
lequel entretien ou nettoyage. Tournant désactivé contrôles volonté pas éliminer ce risque.
7. Le installation et ambiant conditions doit se conformer avec le règlements dans le pertinent
international, national ou régional normes.
8. Éviter non autorisé démontage, équipement modifications, ou logiciel code modifications.
9. Notre entreprise devoir aussi pas être responsable pour le suivant situations ou leur
conséquences:
• Dommage causé par forcer majeure événements tel comme tremblements de terre,
incendies, tempêtes, inondations, ou coulées de boue.
• Lié au transport dégâts pendant client manutention.
• Équipement dommage exigible à incorrect stockage conditions comme décrit dans le
manuel.
• Matériel dommage ou données perte résultant depuis client négligence, incorrect utiliser, ou
intentionnel dommage.
• Système dommage causé par troisième fêtes ou clients, y compris incorrect manutention ou
installation pas dans doubler avec le manuels instructions.
• Dommage depuis ajustements, modifications, ou suppression de étiquettes pas autorisé
dans le manuel.
• Utiliser de le unité dans environnements pas conforme avec pertinent international, national,
ou régional normes.
• installation ou opération par non autorisé personnel.
• Utiliser de fourni par le client matériels ou outils que faire pas rencontrer locale légal
exigences ou pertinent normes.

• Ce unité est pas destiné pour utiliser avec appareils que avoir haute performance exigences
pour UPS (Alimentation Sans Interruption), y compris mais pas limité à données serveurs,
postes de travail, médical équipement, et similaire appareils. Notre entreprise devoir pas être
responsable pour n'importe lequel données perte ou équipement dommage résultant depuis
le violation de ce exigence.
Suivre ces lignes directrices pour approprié utiliser.
Attention
JUST POWER ON 63
FR
SAUVEGARDER CES INSTRUCTIONS – Ce manuel contient important sécurité et en
fonctionnement instructions pour RV5.
1.1 Général Instructions
1.1.1 Déclaration
Avant installation, en fonctionnement, ou maintenir ce unité, s'il te plaît lire ce manuel
soigneusement et suivre tous sécurité précautions indiqué sur le unité et dans ce manuel.
Regarder pour et suivre tous "Note", "Attention", "Prudence", "Avertissement", et "Danger"
déclarations dans ce manuel. Le sécurité lignes directrices fourni ici faire pas couverture tous
possible sécurité considérer Veuillez respecter toutes les normes internationales, nationales ou
régionales pertinentes, ainsi que industrie pratiques. Notre entreprise devoir pas être respons-
able pour dégâts résultant depuis non-conformité ance avec ces sécurité exigences ou
normes.
Pour problèmes ou opérations pas couvert dans ce manuel, s'il te plaît contact BLUETTI
soutien, autre Nous ne sommes pas responsables des dommages ou blessures causés par des
opérations non autorisées. Toujours considérer le réel sur place conditions quand en utilisant le
unité. Utiliser il seulement dans environnements que rencontrer le exigences décrit dans ce
manuel. Échec à faire donc peut cause équipement dysfonctionnements ou dommage,
lequel sont pas couvert par le garantie. Notre entreprise est pas responsable pour n'importe
lequel blessures ou propriété dommage causé par incorrect utiliser.
Ainsi, pour approprié installation et utiliser de ce unité, c'est crucial à adhérer à le suivant guide
lignes:
1. Toujours fonctionner ou magasin le unité dans le conditions spécifié dans ce manuel.
2. PRUDENCE – À réduire risque de blessure, charge seulement LiFePO4 ou plomb-acide piles
taper rechargeable piles . Autre types de piles peut éclatement causant personnel blessure et
dommage.
3. Faire pas exposer le unité à pluie ou neige.
4. Utiliser de un pièce jointe pas recommandé ou vendu par nous peut résultat dans un risque
de feu, électrique choc, ou blessure à personnes.
5. Faire pas démonter le RV5; prendre il à un qualifié militaire quand service ou réparation est
requis. Incorrect remontage peut résultat dans un risque de électrique choc ou feu.
6. À réduire risque de électrique choc, débrancher le RV5 depuis le sortie avant tenter n'importe
lequel entretien ou nettoyage. Tournant désactivé contrôles volonté pas éliminer ce risque.
7. Le installation et ambiant conditions doit se conformer avec le règlements dans le pertinent
international, national ou régional normes.
8. Éviter non autorisé démontage, équipement modifications, ou logiciel code modifications.
9. Notre entreprise devoir aussi pas être responsable pour le suivant situations ou leur
conséquences:
• Dommage causé par forcer majeure événements tel comme tremblements de terre,
incendies, tempêtes, inondations, ou coulées de boue.
• Lié au transport dégâts pendant client manutention.
• Équipement dommage exigible à incorrect stockage conditions comme décrit dans le
manuel.
• Matériel dommage ou données perte résultant depuis client négligence, incorrect utiliser, ou
intentionnel dommage.
• Système dommage causé par troisième fêtes ou clients, y compris incorrect manutention ou
installation pas dans doubler avec le manuels instructions.
• Dommage depuis ajustements, modifications, ou suppression de étiquettes pas autorisé
dans le manuel.
• Utiliser de le unité dans environnements pas conforme avec pertinent international, national,
ou régional normes.
• installation ou opération par non autorisé personnel.
• Utiliser de fourni par le client matériels ou outils que faire pas rencontrer locale légal
exigences ou pertinent normes.

FR
JUST POWER ON
64
1. Faire pas installer, utiliser, ou maintenir le unité dans négatif météo conditions tel comme foudre,
pluie, neige, et fort brises (y compris manutention, en fonctionnement, bouchage et débrancher
signal relations pour de plein air installations, fonctionnement à hauteurs, et de plein air installations).
2. Garder le unité loin depuis chaleur sources ou haut températures, et faire pas exposer il à direct
soleil.
3. Faire pas faire le ménage le unité avec eau.
4. Régulièrement inspecter le unité et c'est accessoires pour signes de dommage ou détérioration.
5. Utiliser un testeur à vérifier pour dangereux tension avant touchant n'importe lequel conducteur
ou Terminal.
6. Dans le événement de un feu, prioriser personnel sécurité. Si sûr à faire donc, immédiatement
déconnecter pouvoir et utiliser un CO2, FM-200, ou abc sec poudre feu extincteur.
7. Si un feu se produit, ÉVACUER le affecté zone rapidement. Activer le le plus proche FEU ALARME
système et CONTACT locale urgence services.
8. Faire pas magasin inflammable ou explosif matériels près le unité.
9. Maintenir un bien ventilé et spacieux installation zone.
10. Faire pas bloc ou couverture le unités ouvertures et évents.
11. Utiliser le unité seulement pour c'est destiné but et s'abstenir depuis empilement objets sur ou
près il pendant stockage ou utiliser.
12. Faire pas se déplacer le unité pendant opération, comme vibrations et chocs depuis mouvement
peut cause dommage.
13. Dans cas de mauvais fonctionnement, immédiatement pouvoir le unité désactivé et contact
BLUETTI soutien ou ton locale BLUETTI revendeur si le manuel fait pas adéquatement expliquer le
problème.
14. Monter le unité en toute sécurité sur un métal support, mur, ou écurie plate-forme à prévenir il
depuis chute. Éviter placement il sur incliné surfaces.
15. Garder le unité dehors de le atteindre de enfants et animaux de compagnie.
16. Faire pas installer le unité où il peut être exposé à eau ou submergé.
17. Faire pas touche le unité quand c'est en cours d'exécution, comme le coquille peut devenir chaud
et pose un risque de brûlures.
1.1.2 Général Exigences
Suivre ces lignes directrices pour approprié utiliser.
Danger

différent types de câbles à moins 1,18 pouces (30 mm) à part et éviter torsion ou passage eux.
3. Tous câble doit être en toute sécurité connecté, bien isolé, et de approprié caractéristiques.
4. Prendre nécessaire mesures à protéger câbles quand passage à travers tuyaux ou trous.
5. dans froid températures, grave impacts ou vibrations peut cause le plastique revêtement de
câbles à devenir fragile et fissure. À assurer sûr installation:
a. Poser et installer tous câbles à températures au-dessus de 0°C (0°C). Poignée câbles avec
soins, en particulier quand fonctionnement dans froid environnements.
b. Si câbles avoir a été stocké dans températures ci-dessous 0°C (0°C), magasin eux à chambre
détrempe- ture pour à moins 24 heures avant installation.
1.5 Manutention Exigences
Tableau 1-1 Recommandé Nombre de Personnes Basé sur le Poids de Produit
1.2 Installation Safety
Danger
Suivre ces lignes directrices pour approprié utiliser.
Note
Se conformer avec en vigueur lois et règlements.
• Quand manutention, installation, câblage, ou maintenir ce produit, se conformer avec le pays
ou région légal règlements et normes.
• Utiliser matériels et outils que rencontrer en vigueur légal exigences et normes.
• Comprendre le opérationnel principes et normes pertinent à le énergie stockage système
dans le emplacement.
JUST POWER ON 65
FR
1. Éviter fonctionnement avec en direct électrique composants.
2. Avant installation, double vérifier le unité pour n'importe lequel signes de dommage ou
défauts à minimiser potentiel risques.
3. Faire bien sûr le unité et tous associé commutateurs sont tourné désactivé (pas dans dormir
mode) à prévenir électrique choc.
4. Faire pas touche n'importe lequel Terminal alors que le unité est en cours d'exécution,
comme il peut pose un risque de électrique choc.
5. Utiliser un testeur à vérifier pour dangereux tension avant touchant n'importe lequel
conducteur ou Terminal.
1.2.1 Général Exigences
1. Après installation, retirer le inactif emballer matériels depuis le site tel comme carton, mousse,
plastique, nylon liens, etc.
2. Garder personnes autre que le installateurs loin depuis le site.
3. Poignée le unité et accessoires soigneusement pendant transport; utiliser original ou
protecteur paquet- ing.
4. Joint câblage ports en toute sécurité avec ignifuger et étanche matériels.
5. Faire pas modifier ou couverture équipement marquages ou plaques signalétiques.
6. Vérifier et faire bien sûr tous sûr gardes, y compris vis et étanche anneaux, sont dans lieu et
correctement resserré.
7. Faire le ménage le unité et accessoires avec un doux tissu; éviter eau ou rude produits
chimiques.
8. Faire pas faire n'importe lequel changements à le unités structure, installation séquence, ou
n'importe lequel autre aspects sans autorisation.
1.2.2 Forage Exigences
Quand forage trous dans le mur ou sur le sol, suivre ces sécurité mesures:
1. Porter lunettes de protection et protecteur gants à tous fois.
2. Bouclier le unité à prévenir débris depuis chute dans il, et retirer tous débris après forage.
3. Percer trous sur le unité est interdit comme il peut dommage le le unités électromagnétique
blindage performance. Le métal copeaux peut cause court circuits sur le circuit conseil.
4. Faire bien sûr à vérifier pour n'importe lequel intégré tuyaux ou câbles avant forage à
prévenir court circuits ou autre dangers.
1.2.3 Emplacement Exigences
1. Situer RV5 loin depuis batterie dans un séparé, Bien ventilé compartiment.
2. Jamais lieu appareil directement au-dessus de batterie; gaz depuis batterie volonté corroder
et dommage appareil.
3. Jamais permettre batterie acide à goutte sur appareil quand en lisant pesanteur ou
remplissage batterie.
4. Faire pas fonctionner appareil dans un fermé zone ou limiter ventilation dans n'importe
lequel chemin.
1.3 Batterie Sécurité
1.3.1 Clause de non-responsabilité
Notre entreprise devoir pas être responsable pour équipement dysfonctionnements,
composant dommage, personnel blessure, propriété perte, ou autre problèmes causé par:
• En utilisant endommagé ou modifié batterie paquets ou appareils.
• En utilisant batterie types pas spécifié dans le manuel ou piles avec non pris en charge
tension.
• Défaut à suivre le batterie utilisateur manuel pour approprié utiliser et manutention.
• Incorrect batterie opérationnel paramètres.
• Court circuits, dommage, gouttes, ou fuites exigible à incorrect utiliser ou relations.
1.3.2 Général Exigences
1. AVERTISSEMENT – RISQUE DE EXPLOSIF GAZ.
2. PRUDENCE – FONCTIONNEMENT DANS ENVIRONS DE UN PLOMB-ACIDE BATTERIE EST
DANGEREUX. PILES GÉNÈRE DES GAZ EXPLOSIFS PENDANT LE FONCTIONNEMENT
NORMAL DE LA BATTERIE. POUR CELA RAISON, IL EST DE MAXIMUM IMPORTANCE QUE
CHAQUE TEMPS AVANT ENTRETIEN LE UNITÉ DANS À PROXIMITÉ DE LA BATTERIE, VOUS
LISEZ CE MANUEL ET SUIVEZ LES INSTRUCTIONS EXACTEMENT.
3. À réduire risque de batterie explosion, suivre ces instructions et ceux publié par batterie
fabricant et fabricant de n'importe lequel unité toi avoir l'intention à utiliser dans environs de
batterie. Revoir de précaution marquage sur ces produits et sur moteur.
4. Ce unité est destiné à recharger piles. Le batterie que est connecté à ce produit est
seulement approprié si il conforme avec le donné batterie standard pour que batterie taper et
est fourni avec un batterie gestion système que volonté moniteur et contrôle le électrique et
thermique santé de le batterie pendant charge. Quand installation ce appareil, le batterie est à
être vérifié comme dans conformité avec le en vigueur batterie standard.
5. ATTENTION – Il est recommandé d'utiliser les batteries fournies par BLUETTI. Non vérifié,
endommagé, ou modifié piles peut pose feu, explosion, ou blessure risques. Si en utilisant un
tierce personne batterie, suivre c'est utilisateur manuel pour approprié utiliser et entretien.
6. Si le batterie a Non intégré protection caractéristiques, installer un correctement noté fusible
ou DC circuit briseur à le Terminal.
7. Utiliser court batterie câbles à minimiser chaleur s'accumuler et améliorer performance.
8. AVERTISSEMENT -Jamais inverse le batteries positif et négatif terminaux. Dommage causé
par incorrect connexion est pas couvert sous garantie.
9. Pour marin utiliser, paire ce unité avec Epad ou n'importe lequel compatible tension et
actuel surveillance appareil à piste le charge processus.
1.3.3 Personnel Précautions
1. Quelqu'un devrait être dans gamme de ton voix ou fermer assez à viens à ton aide quand toi
travail près un plomb-acide batterie.
2. Avoir beaucoup de frais eau et savon proche dans cas batterie acide contacts peau,
vêtements, ou yeux.
3. Porter complet œil protection et vêtements protection. Éviter touchant yeux alors que
fonctionnement près batterie.
4. Si batterie acide contacts peau ou vêtements, laver immédiatement avec savon et eau. Si
acide entre yeux, rincer immédiatement les yeux à l'eau froide courante pendant au moins 10
minutes et consulter un médecin attention immédiatement.
5. JAMAIS fumée ou permettre un étincelle ou flamme dans environs de batterie ou moteur.
6. Être supplémentaire prudent à réduire risque de goutte un métal outil sur batterie. Il pourrait
étincelle ou court-circuit batterie ou autre électrique partie que peut cause explosion.
7. Retirez vos objets personnels en métal tels que bagues, bracelets, colliers et montres lorsque
fonctionnement avec un plomb-acide batterie. UN plomb-acide batterie peut produire un
court-circuit actuel haut assez à souder un anneau ou le comme à métal, causant un grave
brûler.
8. JAMAIS charge un congelé batterie.
9. Si nécessaire à retirer batterie depuis navire, toujours retirer fondé Terminal depuis batterie
d'abord. Faire bien sûr tous accessoires dans le navires sont désactivé, donc comme pas à
cause un arc.
10. Être bien sûr zone autour batterie est Bien ventilé.
11. Faire le ménage batterie terminaux. Être prudent à garder corrosion depuis à venir dans
contact avec yeux.
12. Étude tous batterie du fabricant spécifique précautions tel comme suppression ou pas
suppression cellule casquettes alors que charge et recommandé tarifs de charge.
13. Ajoutez de l'eau distillée dans chaque cellule jusqu'à ce que l'acide de la batterie atteigne le
niveau spécifié par la batterie fabricant. Ce aide purge excessif gaz depuis cellules. Faire pas
déborder. Pour un batterie sans cellule casquettes, soigneusement suivre du fabricant
recharger instructions.
1.3.4 DC Connexion Précautions
1. Connecter et déconnecter batterie relations seulement après paramètre n'importe lequel
appareil commutateurs à désactivé position et suppression CA corde depuis électrique sortie
ou ouverture CA déconnecter.
2. EXTERNE RELATIONS À CHARGEUR DEVOIR SE CONFORMER AVEC LE UNI ÉTATS CÔTE
GARDE ÉLECTRIQUE RÈGLEMENTS (33CFR183, SOUS PARTIE JE).
1.4 Électrique Sécurité
1.4.1 Général Exigences
1. Assurer tous électrique relations se conformer avec national/régional électrique normes.
2. Fourni par l'utilisateur câbles devrait rencontrer locale légal exigences.
3. Utiliser spécialisé isolé outils pour électrique travail.
1.4.2 Mise à la terre Exigences
1. Avant en fonctionnement le unité, toujours confirmer que il est correctement fondé à
réduire le risque de électrique choc.
2. Prendre soins pas à dommage le mise à la terre conducteur.
3. Relations à unité devrait se conformer avec tous locale codes et ordonnances.
4. Selon à IEC62109-1 lignes directrices, si le sol fil est endommagé ou déconnecté, connecter
un protecteur sol fil à assurer sûr utiliser de le unité. Assurer le sol fil rencontre à moins un de
ces critères:
a. Utiliser un monocœur de plein air cuivre câble avec un conducteur transversale zone de ≥10
mm2 si le éducation physique Terminal dans le CA connecteur est pas connecté.
b. Utiliser câbles avec le même fil diamètre comme le CA sortir câbles, mise à la terre les deux le
éducation physique Terminal dans le CA connecteur et le châssis mise à la terre vis
séparément.
1.4.3 Câblage Exigences
1. Garder câbles à moins 1,18 pouces (30 mm) loin depuis chaleur sources et appareils que
émettre chaleur, comme haut températures peut cause isolation à âge ou devenir
endommagé.
2. Paquet câbles de similaire types ensemble à réduire électromagnétique ingérence. Garder

différent types de câbles à moins 1,18 pouces (30 mm) à part et éviter torsion ou passage eux.
3. Tous câble doit être en toute sécurité connecté, bien isolé, et de approprié caractéristiques.
4. Prendre nécessaire mesures à protéger câbles quand passage à travers tuyaux ou trous.
5. dans froid températures, grave impacts ou vibrations peut cause le plastique revêtement de
câbles à devenir fragile et fissure. À assurer sûr installation:
a. Poser et installer tous câbles à températures au-dessus de 0°C (0°C). Poignée câbles avec
soins, en particulier quand fonctionnement dans froid environnements.
b. Si câbles avoir a été stocké dans températures ci-dessous 0°C (0°C), magasin eux à chambre
détrempe- ture pour à moins 24 heures avant installation.
1.5 Manutention Exigences
Tableau 1-1 Recommandé Nombre de Personnes Basé sur le Poids de Produit
FR
JUST POWER ON
66
1. Éviter fonctionnement avec en direct électrique composants.
2. Avant installation, double vérifier le unité pour n'importe lequel signes de dommage ou
défauts à minimiser potentiel risques.
3. Faire bien sûr le unité et tous associé commutateurs sont tourné désactivé (pas dans dormir
mode) à prévenir électrique choc.
4. Faire pas touche n'importe lequel Terminal alors que le unité est en cours d'exécution,
comme il peut pose un risque de électrique choc.
5. Utiliser un testeur à vérifier pour dangereux tension avant touchant n'importe lequel
conducteur ou Terminal.
1.2.1 Général Exigences
1. Après installation, retirer le inactif emballer matériels depuis le site tel comme carton, mousse,
plastique, nylon liens, etc.
2. Garder personnes autre que le installateurs loin depuis le site.
3. Poignée le unité et accessoires soigneusement pendant transport; utiliser original ou
protecteur paquet- ing.
4. Joint câblage ports en toute sécurité avec ignifuger et étanche matériels.
5. Faire pas modifier ou couverture équipement marquages ou plaques signalétiques.
6. Vérifier et faire bien sûr tous sûr gardes, y compris vis et étanche anneaux, sont dans lieu et
correctement resserré.
7. Faire le ménage le unité et accessoires avec un doux tissu; éviter eau ou rude produits
chimiques.
8. Faire pas faire n'importe lequel changements à le unités structure, installation séquence, ou
n'importe lequel autre aspects sans autorisation.
1.2.2 Forage Exigences
Quand forage trous dans le mur ou sur le sol, suivre ces sécurité mesures:
1. Porter lunettes de protection et protecteur gants à tous fois.
2. Bouclier le unité à prévenir débris depuis chute dans il, et retirer tous débris après forage.
3. Percer trous sur le unité est interdit comme il peut dommage le le unités électromagnétique
blindage performance. Le métal copeaux peut cause court circuits sur le circuit conseil.
4. Faire bien sûr à vérifier pour n'importe lequel intégré tuyaux ou câbles avant forage à
prévenir court circuits ou autre dangers.
1.2.3 Emplacement Exigences
1. Situer RV5 loin depuis batterie dans un séparé, Bien ventilé compartiment.
2. Jamais lieu appareil directement au-dessus de batterie; gaz depuis batterie volonté corroder
et dommage appareil.
3. Jamais permettre batterie acide à goutte sur appareil quand en lisant pesanteur ou
remplissage batterie.
4. Faire pas fonctionner appareil dans un fermé zone ou limiter ventilation dans n'importe
lequel chemin.
1.3 Batterie Sécurité
1.3.1 Clause de non-responsabilité
Notre entreprise devoir pas être responsable pour équipement dysfonctionnements,
composant dommage, personnel blessure, propriété perte, ou autre problèmes causé par:
• En utilisant endommagé ou modifié batterie paquets ou appareils.
• En utilisant batterie types pas spécifié dans le manuel ou piles avec non pris en charge
tension.
• Défaut à suivre le batterie utilisateur manuel pour approprié utiliser et manutention.
• Incorrect batterie opérationnel paramètres.
• Court circuits, dommage, gouttes, ou fuites exigible à incorrect utiliser ou relations.
1.3.2 Général Exigences
1. AVERTISSEMENT – RISQUE DE EXPLOSIF GAZ.
2. PRUDENCE – FONCTIONNEMENT DANS ENVIRONS DE UN PLOMB-ACIDE BATTERIE EST
DANGEREUX. PILES GÉNÈRE DES GAZ EXPLOSIFS PENDANT LE FONCTIONNEMENT
NORMAL DE LA BATTERIE. POUR CELA RAISON, IL EST DE MAXIMUM IMPORTANCE QUE
CHAQUE TEMPS AVANT ENTRETIEN LE UNITÉ DANS À PROXIMITÉ DE LA BATTERIE, VOUS
LISEZ CE MANUEL ET SUIVEZ LES INSTRUCTIONS EXACTEMENT.
3. À réduire risque de batterie explosion, suivre ces instructions et ceux publié par batterie
fabricant et fabricant de n'importe lequel unité toi avoir l'intention à utiliser dans environs de
batterie. Revoir de précaution marquage sur ces produits et sur moteur.
4. Ce unité est destiné à recharger piles. Le batterie que est connecté à ce produit est
seulement approprié si il conforme avec le donné batterie standard pour que batterie taper et
est fourni avec un batterie gestion système que volonté moniteur et contrôle le électrique et
thermique santé de le batterie pendant charge. Quand installation ce appareil, le batterie est à
être vérifié comme dans conformité avec le en vigueur batterie standard.
5. ATTENTION – Il est recommandé d'utiliser les batteries fournies par BLUETTI. Non vérifié,
endommagé, ou modifié piles peut pose feu, explosion, ou blessure risques. Si en utilisant un
tierce personne batterie, suivre c'est utilisateur manuel pour approprié utiliser et entretien.
6. Si le batterie a Non intégré protection caractéristiques, installer un correctement noté fusible
ou DC circuit briseur à le Terminal.
7. Utiliser court batterie câbles à minimiser chaleur s'accumuler et améliorer performance.
8. AVERTISSEMENT -Jamais inverse le batteries positif et négatif terminaux. Dommage causé
par incorrect connexion est pas couvert sous garantie.
9. Pour marin utiliser, paire ce unité avec Epad ou n'importe lequel compatible tension et
actuel surveillance appareil à piste le charge processus.
1.3.3 Personnel Précautions
1. Quelqu'un devrait être dans gamme de ton voix ou fermer assez à viens à ton aide quand toi
travail près un plomb-acide batterie.
2. Avoir beaucoup de frais eau et savon proche dans cas batterie acide contacts peau,
vêtements, ou yeux.
3. Porter complet œil protection et vêtements protection. Éviter touchant yeux alors que
fonctionnement près batterie.
4. Si batterie acide contacts peau ou vêtements, laver immédiatement avec savon et eau. Si
acide entre yeux, rincer immédiatement les yeux à l'eau froide courante pendant au moins 10
minutes et consulter un médecin attention immédiatement.
5. JAMAIS fumée ou permettre un étincelle ou flamme dans environs de batterie ou moteur.
6. Être supplémentaire prudent à réduire risque de goutte un métal outil sur batterie. Il pourrait
étincelle ou court-circuit batterie ou autre électrique partie que peut cause explosion.
7. Retirez vos objets personnels en métal tels que bagues, bracelets, colliers et montres lorsque
fonctionnement avec un plomb-acide batterie. UN plomb-acide batterie peut produire un
court-circuit actuel haut assez à souder un anneau ou le comme à métal, causant un grave
brûler.
8. JAMAIS charge un congelé batterie.
9. Si nécessaire à retirer batterie depuis navire, toujours retirer fondé Terminal depuis batterie
d'abord. Faire bien sûr tous accessoires dans le navires sont désactivé, donc comme pas à
cause un arc.
10. Être bien sûr zone autour batterie est Bien ventilé.
11. Faire le ménage batterie terminaux. Être prudent à garder corrosion depuis à venir dans
contact avec yeux.
12. Étude tous batterie du fabricant spécifique précautions tel comme suppression ou pas
suppression cellule casquettes alors que charge et recommandé tarifs de charge.
13. Ajoutez de l'eau distillée dans chaque cellule jusqu'à ce que l'acide de la batterie atteigne le
niveau spécifié par la batterie fabricant. Ce aide purge excessif gaz depuis cellules. Faire pas
déborder. Pour un batterie sans cellule casquettes, soigneusement suivre du fabricant
recharger instructions.
1.3.4 DC Connexion Précautions
1. Connecter et déconnecter batterie relations seulement après paramètre n'importe lequel
appareil commutateurs à désactivé position et suppression CA corde depuis électrique sortie
ou ouverture CA déconnecter.
2. EXTERNE RELATIONS À CHARGEUR DEVOIR SE CONFORMER AVEC LE UNI ÉTATS CÔTE
GARDE ÉLECTRIQUE RÈGLEMENTS (33CFR183, SOUS PARTIE JE).
1.4 Électrique Sécurité
1.4.1 Général Exigences
1. Assurer tous électrique relations se conformer avec national/régional électrique normes.
2. Fourni par l'utilisateur câbles devrait rencontrer locale légal exigences.
3. Utiliser spécialisé isolé outils pour électrique travail.
1.4.2 Mise à la terre Exigences
1. Avant en fonctionnement le unité, toujours confirmer que il est correctement fondé à
réduire le risque de électrique choc.
2. Prendre soins pas à dommage le mise à la terre conducteur.
3. Relations à unité devrait se conformer avec tous locale codes et ordonnances.
4. Selon à IEC62109-1 lignes directrices, si le sol fil est endommagé ou déconnecté, connecter
un protecteur sol fil à assurer sûr utiliser de le unité. Assurer le sol fil rencontre à moins un de
ces critères:
a. Utiliser un monocœur de plein air cuivre câble avec un conducteur transversale zone de ≥10
mm2 si le éducation physique Terminal dans le CA connecteur est pas connecté.
b. Utiliser câbles avec le même fil diamètre comme le CA sortir câbles, mise à la terre les deux le
éducation physique Terminal dans le CA connecteur et le châssis mise à la terre vis
séparément.
1.4.3 Câblage Exigences
1. Garder câbles à moins 1,18 pouces (30 mm) loin depuis chaleur sources et appareils que
émettre chaleur, comme haut températures peut cause isolation à âge ou devenir
endommagé.
2. Paquet câbles de similaire types ensemble à réduire électromagnétique ingérence. Garder

différent types de câbles à moins 1,18 pouces (30 mm) à part et éviter torsion ou passage eux.
3. Tous câble doit être en toute sécurité connecté, bien isolé, et de approprié caractéristiques.
4. Prendre nécessaire mesures à protéger câbles quand passage à travers tuyaux ou trous.
5. dans froid températures, grave impacts ou vibrations peut cause le plastique revêtement de
câbles à devenir fragile et fissure. À assurer sûr installation:
a. Poser et installer tous câbles à températures au-dessus de 0°C (0°C). Poignée câbles avec
soins, en particulier quand fonctionnement dans froid environnements.
b. Si câbles avoir a été stocké dans températures ci-dessous 0°C (0°C), magasin eux à chambre
détrempe- ture pour à moins 24 heures avant installation.
1.5 Manutention Exigences
Tableau 1-1 Recommandé Nombre de Personnes Basé sur le Poids de Produit
JUST POWER ON 67
FR
1. Éviter fonctionnement avec en direct électrique composants.
2. Avant installation, double vérifier le unité pour n'importe lequel signes de dommage ou
défauts à minimiser potentiel risques.
3. Faire bien sûr le unité et tous associé commutateurs sont tourné désactivé (pas dans dormir
mode) à prévenir électrique choc.
4. Faire pas touche n'importe lequel Terminal alors que le unité est en cours d'exécution,
comme il peut pose un risque de électrique choc.
5. Utiliser un testeur à vérifier pour dangereux tension avant touchant n'importe lequel
conducteur ou Terminal.
1.2.1 Général Exigences
1. Après installation, retirer le inactif emballer matériels depuis le site tel comme carton, mousse,
plastique, nylon liens, etc.
2. Garder personnes autre que le installateurs loin depuis le site.
3. Poignée le unité et accessoires soigneusement pendant transport; utiliser original ou
protecteur paquet- ing.
4. Joint câblage ports en toute sécurité avec ignifuger et étanche matériels.
5. Faire pas modifier ou couverture équipement marquages ou plaques signalétiques.
6. Vérifier et faire bien sûr tous sûr gardes, y compris vis et étanche anneaux, sont dans lieu et
correctement resserré.
7. Faire le ménage le unité et accessoires avec un doux tissu; éviter eau ou rude produits
chimiques.
8. Faire pas faire n'importe lequel changements à le unités structure, installation séquence, ou
n'importe lequel autre aspects sans autorisation.
1.2.2 Forage Exigences
Quand forage trous dans le mur ou sur le sol, suivre ces sécurité mesures:
1. Porter lunettes de protection et protecteur gants à tous fois.
2. Bouclier le unité à prévenir débris depuis chute dans il, et retirer tous débris après forage.
3. Percer trous sur le unité est interdit comme il peut dommage le le unités électromagnétique
blindage performance. Le métal copeaux peut cause court circuits sur le circuit conseil.
4. Faire bien sûr à vérifier pour n'importe lequel intégré tuyaux ou câbles avant forage à
prévenir court circuits ou autre dangers.
1.2.3 Emplacement Exigences
1. Situer RV5 loin depuis batterie dans un séparé, Bien ventilé compartiment.
2. Jamais lieu appareil directement au-dessus de batterie; gaz depuis batterie volonté corroder
et dommage appareil.
3. Jamais permettre batterie acide à goutte sur appareil quand en lisant pesanteur ou
remplissage batterie.
4. Faire pas fonctionner appareil dans un fermé zone ou limiter ventilation dans n'importe
lequel chemin.
1.3 Batterie Sécurité
1.3.1 Clause de non-responsabilité
Notre entreprise devoir pas être responsable pour équipement dysfonctionnements,
composant dommage, personnel blessure, propriété perte, ou autre problèmes causé par:
• En utilisant endommagé ou modifié batterie paquets ou appareils.
• En utilisant batterie types pas spécifié dans le manuel ou piles avec non pris en charge
tension.
• Défaut à suivre le batterie utilisateur manuel pour approprié utiliser et manutention.
• Incorrect batterie opérationnel paramètres.
• Court circuits, dommage, gouttes, ou fuites exigible à incorrect utiliser ou relations.
1.3.2 Général Exigences
1. AVERTISSEMENT – RISQUE DE EXPLOSIF GAZ.
2. PRUDENCE – FONCTIONNEMENT DANS ENVIRONS DE UN PLOMB-ACIDE BATTERIE EST
DANGEREUX. PILES GÉNÈRE DES GAZ EXPLOSIFS PENDANT LE FONCTIONNEMENT
NORMAL DE LA BATTERIE. POUR CELA RAISON, IL EST DE MAXIMUM IMPORTANCE QUE
CHAQUE TEMPS AVANT ENTRETIEN LE UNITÉ DANS À PROXIMITÉ DE LA BATTERIE, VOUS
LISEZ CE MANUEL ET SUIVEZ LES INSTRUCTIONS EXACTEMENT.
3. À réduire risque de batterie explosion, suivre ces instructions et ceux publié par batterie
fabricant et fabricant de n'importe lequel unité toi avoir l'intention à utiliser dans environs de
batterie. Revoir de précaution marquage sur ces produits et sur moteur.
4. Ce unité est destiné à recharger piles. Le batterie que est connecté à ce produit est
seulement approprié si il conforme avec le donné batterie standard pour que batterie taper et
est fourni avec un batterie gestion système que volonté moniteur et contrôle le électrique et
thermique santé de le batterie pendant charge. Quand installation ce appareil, le batterie est à
être vérifié comme dans conformité avec le en vigueur batterie standard.
5. ATTENTION – Il est recommandé d'utiliser les batteries fournies par BLUETTI. Non vérifié,
endommagé, ou modifié piles peut pose feu, explosion, ou blessure risques. Si en utilisant un
tierce personne batterie, suivre c'est utilisateur manuel pour approprié utiliser et entretien.
6. Si le batterie a Non intégré protection caractéristiques, installer un correctement noté fusible
ou DC circuit briseur à le Terminal.
7. Utiliser court batterie câbles à minimiser chaleur s'accumuler et améliorer performance.
8. AVERTISSEMENT -Jamais inverse le batteries positif et négatif terminaux. Dommage causé
par incorrect connexion est pas couvert sous garantie.
9. Pour marin utiliser, paire ce unité avec Epad ou n'importe lequel compatible tension et
actuel surveillance appareil à piste le charge processus.
1.3.3 Personnel Précautions
1. Quelqu'un devrait être dans gamme de ton voix ou fermer assez à viens à ton aide quand toi
travail près un plomb-acide batterie.
2. Avoir beaucoup de frais eau et savon proche dans cas batterie acide contacts peau,
vêtements, ou yeux.
3. Porter complet œil protection et vêtements protection. Éviter touchant yeux alors que
fonctionnement près batterie.
4. Si batterie acide contacts peau ou vêtements, laver immédiatement avec savon et eau. Si
acide entre yeux, rincer immédiatement les yeux à l'eau froide courante pendant au moins 10
minutes et consulter un médecin attention immédiatement.
5. JAMAIS fumée ou permettre un étincelle ou flamme dans environs de batterie ou moteur.
6. Être supplémentaire prudent à réduire risque de goutte un métal outil sur batterie. Il pourrait
étincelle ou court-circuit batterie ou autre électrique partie que peut cause explosion.
7. Retirez vos objets personnels en métal tels que bagues, bracelets, colliers et montres lorsque
fonctionnement avec un plomb-acide batterie. UN plomb-acide batterie peut produire un
court-circuit actuel haut assez à souder un anneau ou le comme à métal, causant un grave
brûler.
8. JAMAIS charge un congelé batterie.
9. Si nécessaire à retirer batterie depuis navire, toujours retirer fondé Terminal depuis batterie
d'abord. Faire bien sûr tous accessoires dans le navires sont désactivé, donc comme pas à
cause un arc.
10. Être bien sûr zone autour batterie est Bien ventilé.
11. Faire le ménage batterie terminaux. Être prudent à garder corrosion depuis à venir dans
contact avec yeux.
12. Étude tous batterie du fabricant spécifique précautions tel comme suppression ou pas
suppression cellule casquettes alors que charge et recommandé tarifs de charge.
13. Ajoutez de l'eau distillée dans chaque cellule jusqu'à ce que l'acide de la batterie atteigne le
niveau spécifié par la batterie fabricant. Ce aide purge excessif gaz depuis cellules. Faire pas
déborder. Pour un batterie sans cellule casquettes, soigneusement suivre du fabricant
recharger instructions.
1.3.4 DC Connexion Précautions
1. Connecter et déconnecter batterie relations seulement après paramètre n'importe lequel
appareil commutateurs à désactivé position et suppression CA corde depuis électrique sortie
ou ouverture CA déconnecter.
2. EXTERNE RELATIONS À CHARGEUR DEVOIR SE CONFORMER AVEC LE UNI ÉTATS CÔTE
GARDE ÉLECTRIQUE RÈGLEMENTS (33CFR183, SOUS PARTIE JE).
1.4 Électrique Sécurité
1.4.1 Général Exigences
1. Assurer tous électrique relations se conformer avec national/régional électrique normes.
2. Fourni par l'utilisateur câbles devrait rencontrer locale légal exigences.
3. Utiliser spécialisé isolé outils pour électrique travail.
1.4.2 Mise à la terre Exigences
1. Avant en fonctionnement le unité, toujours confirmer que il est correctement fondé à
réduire le risque de électrique choc.
2. Prendre soins pas à dommage le mise à la terre conducteur.
3. Relations à unité devrait se conformer avec tous locale codes et ordonnances.
4. Selon à IEC62109-1 lignes directrices, si le sol fil est endommagé ou déconnecté, connecter
un protecteur sol fil à assurer sûr utiliser de le unité. Assurer le sol fil rencontre à moins un de
ces critères:
a. Utiliser un monocœur de plein air cuivre câble avec un conducteur transversale zone de ≥10
mm2 si le éducation physique Terminal dans le CA connecteur est pas connecté.
b. Utiliser câbles avec le même fil diamètre comme le CA sortir câbles, mise à la terre les deux le
éducation physique Terminal dans le CA connecteur et le châssis mise à la terre vis
séparément.
1.4.3 Câblage Exigences
1. Garder câbles à moins 1,18 pouces (30 mm) loin depuis chaleur sources et appareils que
émettre chaleur, comme haut températures peut cause isolation à âge ou devenir
endommagé.
2. Paquet câbles de similaire types ensemble à réduire électromagnétique ingérence. Garder

différent types de câbles à moins 1,18 pouces (30 mm) à part et éviter torsion ou passage eux.
3. Tous câble doit être en toute sécurité connecté, bien isolé, et de approprié caractéristiques.
4. Prendre nécessaire mesures à protéger câbles quand passage à travers tuyaux ou trous.
5. dans froid températures, grave impacts ou vibrations peut cause le plastique revêtement de
câbles à devenir fragile et fissure. À assurer sûr installation:
a. Poser et installer tous câbles à températures au-dessus de 0°C (0°C). Poignée câbles avec
soins, en particulier quand fonctionnement dans froid environnements.
b. Si câbles avoir a été stocké dans températures ci-dessous 0°C (0°C), magasin eux à chambre
détrempe- ture pour à moins 24 heures avant installation.
1.5 Manutention Exigences
Tableau 1-1 Recommandé Nombre de Personnes Basé sur le Poids de Produit
FR
JUST POWER ON
68
1. Éviter fonctionnement avec en direct électrique composants.
2. Avant installation, double vérifier le unité pour n'importe lequel signes de dommage ou
défauts à minimiser potentiel risques.
3. Faire bien sûr le unité et tous associé commutateurs sont tourné désactivé (pas dans dormir
mode) à prévenir électrique choc.
4. Faire pas touche n'importe lequel Terminal alors que le unité est en cours d'exécution,
comme il peut pose un risque de électrique choc.
5. Utiliser un testeur à vérifier pour dangereux tension avant touchant n'importe lequel
conducteur ou Terminal.
1.2.1 Général Exigences
1. Après installation, retirer le inactif emballer matériels depuis le site tel comme carton, mousse,
plastique, nylon liens, etc.
2. Garder personnes autre que le installateurs loin depuis le site.
3. Poignée le unité et accessoires soigneusement pendant transport; utiliser original ou
protecteur paquet- ing.
4. Joint câblage ports en toute sécurité avec ignifuger et étanche matériels.
5. Faire pas modifier ou couverture équipement marquages ou plaques signalétiques.
6. Vérifier et faire bien sûr tous sûr gardes, y compris vis et étanche anneaux, sont dans lieu et
correctement resserré.
7. Faire le ménage le unité et accessoires avec un doux tissu; éviter eau ou rude produits
chimiques.
8. Faire pas faire n'importe lequel changements à le unités structure, installation séquence, ou
n'importe lequel autre aspects sans autorisation.
1.2.2 Forage Exigences
Quand forage trous dans le mur ou sur le sol, suivre ces sécurité mesures:
1. Porter lunettes de protection et protecteur gants à tous fois.
2. Bouclier le unité à prévenir débris depuis chute dans il, et retirer tous débris après forage.
3. Percer trous sur le unité est interdit comme il peut dommage le le unités électromagnétique
blindage performance. Le métal copeaux peut cause court circuits sur le circuit conseil.
4. Faire bien sûr à vérifier pour n'importe lequel intégré tuyaux ou câbles avant forage à
prévenir court circuits ou autre dangers.
1.2.3 Emplacement Exigences
1. Situer RV5 loin depuis batterie dans un séparé, Bien ventilé compartiment.
2. Jamais lieu appareil directement au-dessus de batterie; gaz depuis batterie volonté corroder
et dommage appareil.
3. Jamais permettre batterie acide à goutte sur appareil quand en lisant pesanteur ou
remplissage batterie.
4. Faire pas fonctionner appareil dans un fermé zone ou limiter ventilation dans n'importe
lequel chemin.
1.3 Batterie Sécurité
1.3.1 Clause de non-responsabilité
Notre entreprise devoir pas être responsable pour équipement dysfonctionnements,
composant dommage, personnel blessure, propriété perte, ou autre problèmes causé par:
• En utilisant endommagé ou modifié batterie paquets ou appareils.
• En utilisant batterie types pas spécifié dans le manuel ou piles avec non pris en charge
tension.
• Défaut à suivre le batterie utilisateur manuel pour approprié utiliser et manutention.
• Incorrect batterie opérationnel paramètres.
• Court circuits, dommage, gouttes, ou fuites exigible à incorrect utiliser ou relations.
1.3.2 Général Exigences
1. AVERTISSEMENT – RISQUE DE EXPLOSIF GAZ.
2. PRUDENCE – FONCTIONNEMENT DANS ENVIRONS DE UN PLOMB-ACIDE BATTERIE EST
DANGEREUX. PILES GÉNÈRE DES GAZ EXPLOSIFS PENDANT LE FONCTIONNEMENT
NORMAL DE LA BATTERIE. POUR CELA RAISON, IL EST DE MAXIMUM IMPORTANCE QUE
CHAQUE TEMPS AVANT ENTRETIEN LE UNITÉ DANS À PROXIMITÉ DE LA BATTERIE, VOUS
LISEZ CE MANUEL ET SUIVEZ LES INSTRUCTIONS EXACTEMENT.
3. À réduire risque de batterie explosion, suivre ces instructions et ceux publié par batterie
fabricant et fabricant de n'importe lequel unité toi avoir l'intention à utiliser dans environs de
batterie. Revoir de précaution marquage sur ces produits et sur moteur.
4. Ce unité est destiné à recharger piles. Le batterie que est connecté à ce produit est
seulement approprié si il conforme avec le donné batterie standard pour que batterie taper et
est fourni avec un batterie gestion système que volonté moniteur et contrôle le électrique et
thermique santé de le batterie pendant charge. Quand installation ce appareil, le batterie est à
être vérifié comme dans conformité avec le en vigueur batterie standard.
5. ATTENTION – Il est recommandé d'utiliser les batteries fournies par BLUETTI. Non vérifié,
endommagé, ou modifié piles peut pose feu, explosion, ou blessure risques. Si en utilisant un
tierce personne batterie, suivre c'est utilisateur manuel pour approprié utiliser et entretien.
6. Si le batterie a Non intégré protection caractéristiques, installer un correctement noté fusible
ou DC circuit briseur à le Terminal.
7. Utiliser court batterie câbles à minimiser chaleur s'accumuler et améliorer performance.
8. AVERTISSEMENT -Jamais inverse le batteries positif et négatif terminaux. Dommage causé
par incorrect connexion est pas couvert sous garantie.
9. Pour marin utiliser, paire ce unité avec Epad ou n'importe lequel compatible tension et
actuel surveillance appareil à piste le charge processus.
1.3.3 Personnel Précautions
1. Quelqu'un devrait être dans gamme de ton voix ou fermer assez à viens à ton aide quand toi
travail près un plomb-acide batterie.
2. Avoir beaucoup de frais eau et savon proche dans cas batterie acide contacts peau,
vêtements, ou yeux.
3. Porter complet œil protection et vêtements protection. Éviter touchant yeux alors que
fonctionnement près batterie.
4. Si batterie acide contacts peau ou vêtements, laver immédiatement avec savon et eau. Si
acide entre yeux, rincer immédiatement les yeux à l'eau froide courante pendant au moins 10
minutes et consulter un médecin attention immédiatement.
5. JAMAIS fumée ou permettre un étincelle ou flamme dans environs de batterie ou moteur.
6. Être supplémentaire prudent à réduire risque de goutte un métal outil sur batterie. Il pourrait
étincelle ou court-circuit batterie ou autre électrique partie que peut cause explosion.
7. Retirez vos objets personnels en métal tels que bagues, bracelets, colliers et montres lorsque
fonctionnement avec un plomb-acide batterie. UN plomb-acide batterie peut produire un
court-circuit actuel haut assez à souder un anneau ou le comme à métal, causant un grave
brûler.
8. JAMAIS charge un congelé batterie.
9. Si nécessaire à retirer batterie depuis navire, toujours retirer fondé Terminal depuis batterie
d'abord. Faire bien sûr tous accessoires dans le navires sont désactivé, donc comme pas à
cause un arc.
10. Être bien sûr zone autour batterie est Bien ventilé.
11. Faire le ménage batterie terminaux. Être prudent à garder corrosion depuis à venir dans
contact avec yeux.
12. Étude tous batterie du fabricant spécifique précautions tel comme suppression ou pas
suppression cellule casquettes alors que charge et recommandé tarifs de charge.
13. Ajoutez de l'eau distillée dans chaque cellule jusqu'à ce que l'acide de la batterie atteigne le
niveau spécifié par la batterie fabricant. Ce aide purge excessif gaz depuis cellules. Faire pas
déborder. Pour un batterie sans cellule casquettes, soigneusement suivre du fabricant
recharger instructions.
1.3.4 DC Connexion Précautions
1. Connecter et déconnecter batterie relations seulement après paramètre n'importe lequel
appareil commutateurs à désactivé position et suppression CA corde depuis électrique sortie
ou ouverture CA déconnecter.
2. EXTERNE RELATIONS À CHARGEUR DEVOIR SE CONFORMER AVEC LE UNI ÉTATS CÔTE
GARDE ÉLECTRIQUE RÈGLEMENTS (33CFR183, SOUS PARTIE JE).
1.4 Électrique Sécurité
1.4.1 Général Exigences
1. Assurer tous électrique relations se conformer avec national/régional électrique normes.
2. Fourni par l'utilisateur câbles devrait rencontrer locale légal exigences.
3. Utiliser spécialisé isolé outils pour électrique travail.
1.4.2 Mise à la terre Exigences
1. Avant en fonctionnement le unité, toujours confirmer que il est correctement fondé à
réduire le risque de électrique choc.
2. Prendre soins pas à dommage le mise à la terre conducteur.
3. Relations à unité devrait se conformer avec tous locale codes et ordonnances.
4. Selon à IEC62109-1 lignes directrices, si le sol fil est endommagé ou déconnecté, connecter
un protecteur sol fil à assurer sûr utiliser de le unité. Assurer le sol fil rencontre à moins un de
ces critères:
a. Utiliser un monocœur de plein air cuivre câble avec un conducteur transversale zone de ≥10
mm2 si le éducation physique Terminal dans le CA connecteur est pas connecté.
b. Utiliser câbles avec le même fil diamètre comme le CA sortir câbles, mise à la terre les deux le
éducation physique Terminal dans le CA connecteur et le châssis mise à la terre vis
séparément.
1.4.3 Câblage Exigences
1. Garder câbles à moins 1,18 pouces (30 mm) loin depuis chaleur sources et appareils que
émettre chaleur, comme haut températures peut cause isolation à âge ou devenir
endommagé.
2. Paquet câbles de similaire types ensemble à réduire électromagnétique ingérence. Garder

différent types de câbles à moins 1,18 pouces (30 mm) à part et éviter torsion ou passage eux.
3. Tous câble doit être en toute sécurité connecté, bien isolé, et de approprié caractéristiques.
4. Prendre nécessaire mesures à protéger câbles quand passage à travers tuyaux ou trous.
5. dans froid températures, grave impacts ou vibrations peut cause le plastique revêtement de
câbles à devenir fragile et fissure. À assurer sûr installation:
a. Poser et installer tous câbles à températures au-dessus de 0°C (0°C). Poignée câbles avec
soins, en particulier quand fonctionnement dans froid environnements.
b. Si câbles avoir a été stocké dans températures ci-dessous 0°C (0°C), magasin eux à chambre
détrempe- ture pour à moins 24 heures avant installation.
1.5 Manutention Exigences
Tableau 1-1 Recommandé Nombre de Personnes Basé sur le Poids de Produit
Poids
<18 kg (39,7 livres)
18 kg à 32 kg (39,7 lb-70,5 lb)
32 kg à 55 kg (70,5 lb-121,3 lb)
>55 kg (121,3 lb)
Nombre de Personnes
1
2
3
4 ou un chariot
JUST POWER ON 69
FR
1. Éviter fonctionnement avec en direct électrique composants.
2. Avant installation, double vérifier le unité pour n'importe lequel signes de dommage ou
défauts à minimiser potentiel risques.
3. Faire bien sûr le unité et tous associé commutateurs sont tourné désactivé (pas dans dormir
mode) à prévenir électrique choc.
4. Faire pas touche n'importe lequel Terminal alors que le unité est en cours d'exécution,
comme il peut pose un risque de électrique choc.
5. Utiliser un testeur à vérifier pour dangereux tension avant touchant n'importe lequel
conducteur ou Terminal.
1.2.1 Général Exigences
1. Après installation, retirer le inactif emballer matériels depuis le site tel comme carton, mousse,
plastique, nylon liens, etc.
2. Garder personnes autre que le installateurs loin depuis le site.
3. Poignée le unité et accessoires soigneusement pendant transport; utiliser original ou
protecteur paquet- ing.
4. Joint câblage ports en toute sécurité avec ignifuger et étanche matériels.
5. Faire pas modifier ou couverture équipement marquages ou plaques signalétiques.
6. Vérifier et faire bien sûr tous sûr gardes, y compris vis et étanche anneaux, sont dans lieu et
correctement resserré.
7. Faire le ménage le unité et accessoires avec un doux tissu; éviter eau ou rude produits
chimiques.
8. Faire pas faire n'importe lequel changements à le unités structure, installation séquence, ou
n'importe lequel autre aspects sans autorisation.
1.2.2 Forage Exigences
Quand forage trous dans le mur ou sur le sol, suivre ces sécurité mesures:
1. Porter lunettes de protection et protecteur gants à tous fois.
2. Bouclier le unité à prévenir débris depuis chute dans il, et retirer tous débris après forage.
3. Percer trous sur le unité est interdit comme il peut dommage le le unités électromagnétique
blindage performance. Le métal copeaux peut cause court circuits sur le circuit conseil.
4. Faire bien sûr à vérifier pour n'importe lequel intégré tuyaux ou câbles avant forage à
prévenir court circuits ou autre dangers.
1.2.3 Emplacement Exigences
1. Situer RV5 loin depuis batterie dans un séparé, Bien ventilé compartiment.
2. Jamais lieu appareil directement au-dessus de batterie; gaz depuis batterie volonté corroder
et dommage appareil.
3. Jamais permettre batterie acide à goutte sur appareil quand en lisant pesanteur ou
remplissage batterie.
4. Faire pas fonctionner appareil dans un fermé zone ou limiter ventilation dans n'importe
lequel chemin.
1.3 Batterie Sécurité
1.3.1 Clause de non-responsabilité
Notre entreprise devoir pas être responsable pour équipement dysfonctionnements,
composant dommage, personnel blessure, propriété perte, ou autre problèmes causé par:
• En utilisant endommagé ou modifié batterie paquets ou appareils.
• En utilisant batterie types pas spécifié dans le manuel ou piles avec non pris en charge
tension.
• Défaut à suivre le batterie utilisateur manuel pour approprié utiliser et manutention.
• Incorrect batterie opérationnel paramètres.
• Court circuits, dommage, gouttes, ou fuites exigible à incorrect utiliser ou relations.
1.3.2 Général Exigences
1. AVERTISSEMENT – RISQUE DE EXPLOSIF GAZ.
2. PRUDENCE – FONCTIONNEMENT DANS ENVIRONS DE UN PLOMB-ACIDE BATTERIE EST
DANGEREUX. PILES GÉNÈRE DES GAZ EXPLOSIFS PENDANT LE FONCTIONNEMENT
NORMAL DE LA BATTERIE. POUR CELA RAISON, IL EST DE MAXIMUM IMPORTANCE QUE
CHAQUE TEMPS AVANT ENTRETIEN LE UNITÉ DANS À PROXIMITÉ DE LA BATTERIE, VOUS
LISEZ CE MANUEL ET SUIVEZ LES INSTRUCTIONS EXACTEMENT.
3. À réduire risque de batterie explosion, suivre ces instructions et ceux publié par batterie
fabricant et fabricant de n'importe lequel unité toi avoir l'intention à utiliser dans environs de
batterie. Revoir de précaution marquage sur ces produits et sur moteur.
4. Ce unité est destiné à recharger piles. Le batterie que est connecté à ce produit est
seulement approprié si il conforme avec le donné batterie standard pour que batterie taper et
est fourni avec un batterie gestion système que volonté moniteur et contrôle le électrique et
thermique santé de le batterie pendant charge. Quand installation ce appareil, le batterie est à
être vérifié comme dans conformité avec le en vigueur batterie standard.
5. ATTENTION – Il est recommandé d'utiliser les batteries fournies par BLUETTI. Non vérifié,
endommagé, ou modifié piles peut pose feu, explosion, ou blessure risques. Si en utilisant un
tierce personne batterie, suivre c'est utilisateur manuel pour approprié utiliser et entretien.
6. Si le batterie a Non intégré protection caractéristiques, installer un correctement noté fusible
ou DC circuit briseur à le Terminal.
7. Utiliser court batterie câbles à minimiser chaleur s'accumuler et améliorer performance.
8. AVERTISSEMENT -Jamais inverse le batteries positif et négatif terminaux. Dommage causé
par incorrect connexion est pas couvert sous garantie.
9. Pour marin utiliser, paire ce unité avec Epad ou n'importe lequel compatible tension et
actuel surveillance appareil à piste le charge processus.
1.3.3 Personnel Précautions
1. Quelqu'un devrait être dans gamme de ton voix ou fermer assez à viens à ton aide quand toi
travail près un plomb-acide batterie.
2. Avoir beaucoup de frais eau et savon proche dans cas batterie acide contacts peau,
vêtements, ou yeux.
3. Porter complet œil protection et vêtements protection. Éviter touchant yeux alors que
fonctionnement près batterie.
4. Si batterie acide contacts peau ou vêtements, laver immédiatement avec savon et eau. Si
acide entre yeux, rincer immédiatement les yeux à l'eau froide courante pendant au moins 10
minutes et consulter un médecin attention immédiatement.
5. JAMAIS fumée ou permettre un étincelle ou flamme dans environs de batterie ou moteur.
6. Être supplémentaire prudent à réduire risque de goutte un métal outil sur batterie. Il pourrait
étincelle ou court-circuit batterie ou autre électrique partie que peut cause explosion.
7. Retirez vos objets personnels en métal tels que bagues, bracelets, colliers et montres lorsque
fonctionnement avec un plomb-acide batterie. UN plomb-acide batterie peut produire un
court-circuit actuel haut assez à souder un anneau ou le comme à métal, causant un grave
brûler.
8. JAMAIS charge un congelé batterie.
9. Si nécessaire à retirer batterie depuis navire, toujours retirer fondé Terminal depuis batterie
d'abord. Faire bien sûr tous accessoires dans le navires sont désactivé, donc comme pas à
cause un arc.
10. Être bien sûr zone autour batterie est Bien ventilé.
11. Faire le ménage batterie terminaux. Être prudent à garder corrosion depuis à venir dans
contact avec yeux.
12. Étude tous batterie du fabricant spécifique précautions tel comme suppression ou pas
suppression cellule casquettes alors que charge et recommandé tarifs de charge.
13. Ajoutez de l'eau distillée dans chaque cellule jusqu'à ce que l'acide de la batterie atteigne le
niveau spécifié par la batterie fabricant. Ce aide purge excessif gaz depuis cellules. Faire pas
déborder. Pour un batterie sans cellule casquettes, soigneusement suivre du fabricant
recharger instructions.
1.3.4 DC Connexion Précautions
1. Connecter et déconnecter batterie relations seulement après paramètre n'importe lequel
appareil commutateurs à désactivé position et suppression CA corde depuis électrique sortie
ou ouverture CA déconnecter.
2. EXTERNE RELATIONS À CHARGEUR DEVOIR SE CONFORMER AVEC LE UNI ÉTATS CÔTE
GARDE ÉLECTRIQUE RÈGLEMENTS (33CFR183, SOUS PARTIE JE).
1.4 Électrique Sécurité
1.4.1 Général Exigences
1. Assurer tous électrique relations se conformer avec national/régional électrique normes.
2. Fourni par l'utilisateur câbles devrait rencontrer locale légal exigences.
3. Utiliser spécialisé isolé outils pour électrique travail.
1.4.2 Mise à la terre Exigences
1. Avant en fonctionnement le unité, toujours confirmer que il est correctement fondé à
réduire le risque de électrique choc.
2. Prendre soins pas à dommage le mise à la terre conducteur.
3. Relations à unité devrait se conformer avec tous locale codes et ordonnances.
4. Selon à IEC62109-1 lignes directrices, si le sol fil est endommagé ou déconnecté, connecter
un protecteur sol fil à assurer sûr utiliser de le unité. Assurer le sol fil rencontre à moins un de
ces critères:
a. Utiliser un monocœur de plein air cuivre câble avec un conducteur transversale zone de ≥10
mm2 si le éducation physique Terminal dans le CA connecteur est pas connecté.
b. Utiliser câbles avec le même fil diamètre comme le CA sortir câbles, mise à la terre les deux le
éducation physique Terminal dans le CA connecteur et le châssis mise à la terre vis
séparément.
1.4.3 Câblage Exigences
1. Garder câbles à moins 1,18 pouces (30 mm) loin depuis chaleur sources et appareils que
émettre chaleur, comme haut températures peut cause isolation à âge ou devenir
endommagé.
2. Paquet câbles de similaire types ensemble à réduire électromagnétique ingérence. Garder

FR
JUST POWER ON
70
• Déclaration de la FCC
(1) L’appareil ne doit pas produire de brouillage nuisible.
(2) L’appareil doit accepter tout brouillage subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Cet équipement a été testé et jugé conforme aux limites d’un appareil numérique de
fournir une protection raisonnable contre les brouillages nuisibles dans une installation
résidentielle. Cet équipement génère, utilise et peut émettre de l’énergie radiofréquence
et, s’il n’est pas installé et utilisé conformément aux instructions, peut provoquer un
brouillage nuisible pour les communications radio. Il n’existe toutefois aucune garantie
qu’aucun brouillage ne se produise dans une installation particulière. Si cet équipement
provoque des brouillages nuisibles pour la réception radio ou télévision, ce qui peut être
déterminé en éteignant et en rallumant l’équipement, il est recommandé d’essayer de
- Réorienter ou déplacer l’antenne de réception.
- Augmenter la séparation entre l’équipement et le récepteur.
- Brancher l’équipement sur une prise d’un circuit différent de celui sur lequel le récepteur
est branché.
- Consulter le revendeur ou un technicien radio/TV expérimenté pour obtenir de l’aide.
Tout changement ou modification non expressément approuvé
par la partie responsable de la conformité pourrait annuler l’autorité de l’utilisateur à
utiliser cet équipement.
Cet équipement est conforme aux limites d’exposition aux rayonnements de la FCC
définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé
Conformité

JUST POWER ON 71
FR
• Mise en garde d’IC
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Sciences et Développement économique Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
L’équipement est conforme aux limites d’exposition aux
rayonnements IC définies pour les environnements non contrôlés. Cet équipement doit être
CAN ICES (B)/NMB(B) (Canada)

Certificate
Inspector:
QC:
P/N:17.0303.0898-00