EFURDEN EDOG15 7000W Portable Inverter Generator Gas ECO Quiet Pure Sine Wave Generator

Product's Documents

Below are documents related to this product, you can read online or download:
EDOG15 photo

User Manual

This is the main product document for model EDOG15.

The file format is pdf, 37 pages, you can download this manual here .

background
INVERTER GENERATOR
EDOG15
Please read and save this manual.
background
1
1
Be sure to read the manual before using, otherwise the wrong operation
will lead to safety risks or equipment damage. As long as follow the operation of
this manual book, the company's inverter generator is safe and reliable.
Safety Warning
The personal and property safety of you and others is very important.
Please read carefully the extremely important safety warnings we have written in
the manual and the label of the generator set.
Safety warnings can alert you to potential dangers that may harm you and
others.
There are one of these three symbols: “Danger”, “Warning”, “Notice” in
front of safety warning. Details as below:
If you do not follow the instructions, your life will be in danger or you will be seriously
injured.
If you do not follow the instructions, your life could be in danger or you will be
seriously injured.
If you do not follow the instructions, you will be slightly injured.
If you do not follow the instructions, your generator set and other property may be
damaged.
background
2
CONTENT
1. SAFETY INFORMATION
.................................................................... 3
2. Labels...................................................................................................... 9
3. Components Identification................................................................10
4. Control System
....................................................................................12
5. Preparations
.........................................................................................15
6. Generator Usage................................................................................ 17
7. Start the Generator
.............................................................................22
8. Stop the Generator
.............................................................................23
9. Maintenance........................................................................................ 24
10. Storage
............................................................................................... 29
11.
Troubleshooting
................................................................................30
12. Circuit Diagram................................................................................. 31
13. Parameter
...........................................................................................32
14. SERVICE INFORMATION
............................................................. 33
To ensure personal and property safety, please read the
following content carefully.
background
3
1. SAFETY INFORMATION
Before use, add gasoline to the red ring in the tank!
Check the oil level before use!
TOXIC FUMES
The engine tail gas contains carbon monoxide, and it
is strictly prohibited to run the generator at the place where the
indoor or the ventilation is not good.
Ensure that adequate ventilation is provided while the
generator is in operation.
The muffler is hot when the generator is running and
just stopping. Be careful not to touch it.
FIRE
Under certain circumstances, gasoline and LPG(if
equipped) is extremely flammable and explosive.
Be sure to add gasoline in a well-ventilated place. Turn
off the engine and let it cool before filling.
When refueling, keep away from the open fire.
If there is oil spill while refueling, wipe the spilled
gasoline immediately.
Use in places with high fire risk should be prohibited.
background
4
ELECTRICAL SHOCK
Do not connect the generator to building’s electrical
system, or it may cause people to die from electric shock when
they come into contact with the wire; damage the generator or
damage the home appliance.
This generator produces powerful voltage and the
electricity CAN KILL YOU.
This generator must be properly connected to an
appropriate ground to help prevent electric shock. Failure to
properly ground generator can result in electrocution,
especially if the generator is equipped with a wheel kit. Consult
an electrician for local grounding requirements.
Installation should be performed by a certified
electrician. Improper installation can result in electrical shock
and death.
The portable generator stator winding is isolated from
the frame and from the AC receptacle ground pin;and
Electrical devices that require a connection between
one conductor pin and the grounded receptacle pin may not
function properly.
background
5
HOT SURFACE
Running engines generators produce heat. Severe
burns can occur on contact.
DO NOT touch generator while operating or just
after stopping. Avoid contact with hot exhaust gases.
Maintain at least three feet of clearance on all sides
to ensure adequate cooling.
Combustible material can catch fire on contact.
Maintain at least five feet of clearance from combustible
materials.
Place the appliance on stable surfaces only.
The load must not exceed the power marked on the
rating label of the generator. Overloading may result in
damage to, or a shorter life of the appliance.
The motor must not be operated with excessive
rotary speed. The operation of the motor with excessive
rotary speed raises the risk of injury. Parts which affect the
rotary speed must not modified or replaced.
Do not operate or store the appliance in wet or
humid surroundings or on highly conductive surfaces such
as metal coatings or steel constructions.
background
6
Poisonous gas!
Engine exhaust gas is poisonous; don’t operate in an
unventilated room. When installed in ventilated room,
additional requirement for fire and explosion protection shall be
observed.
A pre-operation check must be performed before
starting the engine to avoid accidents or equipment damage.
Generators must operate at least one meter away from
the building and other equipment.
Please put the generator on the horizontal ground. If
the generator is tilted, it may cause gasoline overflow.
Be sure to master how to quickly shut off generators
and understand the operation of all control components.
Children and pets must stay away from the operating area. While
the engine is running, all personnel must be away from its rotating
parts.
background
7
If the operation is not proper, there is a potential
danger to the generator. Do not operate the generator with a
wet hand.
Do not operate in the rain, snow, lest wet generator.
Maintenance of generators should be by professionals
only.
It is strictly forbidden to use in an indoor or enclosed
environment.
Do not use in environments with explosion hazard.
The operation and maintenance of equipment requires
the use of personal protective equipment such as gloves,
earmuffs, etc.
These labels warn you of potential dangers that can
cause serious casualties. Please read carefully the label
contents described in this manual, as well as safety warnings
and comments. If the label has fallen off or cannot be seen
clearly, please contact our distributor and replace it.
Electrical safety
Before use, the generating set and its electrical
equipment (including lines and plug connections) should be
checked to ensure that they are not defective.
Protection against electrical shock depends on circuit
breakers specially matched to the generating set. If the circuit
breakers require replacement, they should be replaced with a
background
8
circuit breaker having identical ratings and performances
characteristics.
Due to high mechanical stresses, only tough
rubber-sheathed flexible cable or the equivalent should be
used.
If you need extension cords, use flexible cables such
as rubber sleeves (compliant with IEC245 or corresponding
requirements).Specification: 14AWG/20ft.the extension
lines should be special used for power supply cord line.
The choice of protection arrangement to be carried out
depending on characteristic of the generator, running
conditions and scheme of grounded liaisons determined by the
user. The user that he shall conform to regulations of electrical
safety applicable to the place where the generating sets are
used. And the requirements and the precautions to be
respected by the user in the case of re-supply by generating
sets of an installation, depending on existing protective
measures in this installation and applicable regulations.
The generator produces enough electric power to
cause a serious shock or electrocution if misused.
Using a generator or electrical appliance in wet
conditions, such as rain or snow, or near a pool or sprinkler
system, or when your hands are wet, could result in
electrocution. Keep the generatordry.
If the generator is stored outdoors, unprotected from
the weather, check all electrical components on the control
panel, before each use. Moisture or ice can cause a
malfunction or short circuit in electrical components which
could result in electrocution.
Do not connect to a building’s electrical system unless
an isolation switch has been installed by a qualified electrician.
background
9
Grounding
The portable generator stator winding is isolated from
the frame and from the AC receptacle ground pin, and
Electrical devices that require a connection between
one conductor pin and the grounded receptacle pin may not
function properly.
2. Labels
2.1 Warning labels
1) CO poisoning hazard label
2) Warning labels
3) Burning hazard label
background
10
2.2 Nameplate
3. Components Identification
3.1 Components Feature
Oil maintenance
cover
Start
switch
Recoil start
handle
Handle
Fuel gauge
Fuel tank cap
Maintenance
cover switch
Handle
Right cover
Handle
Muffler
cover
Spark plug
maintenance cover
Muffler
exhaust port
Left cover
Maintenance cover
switch
cover
Shock-absorbing
seat
Wheel
background
11
3.2 Control Panel
Depending on the configuration, the factory will make the
appropriate adjustments, those changes are without separate notice.
1.Reset Button
2.Low oil indicator (yellow)
3.Overload indicator (red)
4.Running indicator (green)
5.AC Socket
6.AC Overload
7.AC Overload
8.Parallel connection
9.Ground protection
10.AC Socket
11.DC Socket
12.DC Overload
13.V.F.T METER
14.ECO Switch
background
12
4. Control System
4.1 Oil Alarm System (Yellow)
The engine oil protection system will stop
the engine automatically if the oil is insufficient
and the oil indicator will turn on. Check the oil
level and re-fill it if necessary then start again.
If the oil alarm indicator flashes for few seconds, it means the oil
capacity is insufficient. Refill the oil and restart the engine.
4.2 Overload Indicator(Red)
4.2.1 When the red indicator light
flashes and the green indicator light remains
on constantly, it indicates that the generator
set has exceeded the rated load. If used for a
long time, the output will be automatically
disconnected. Please reduce the load equipment or lower the load power
to the rated power range.
4.2.2 When the green indicator light goes out and the red indicator
light flashes 6 times every 3 seconds, it indicates that the output of the
generator set is disconnected due to overload protection or short circuit.
Please reduce the load equipment or lower the load power to the rated
power range, or remove the short circuit fault, and then gently touch the
reset button. When the green indicator light is on again, it indicates that the
generator set is operating normally.
4.2.3 When the green indicator light is off and the red indicator flashes
3 times every 3s, it indicates that the operating temperature of the
generator set has exceeded the limit. Please turn off the generator set and
background
13
place it in a well-ventilated environment with a temperature below 40
before using it again. Or reduce the load power and then gently touch the
reset button. When the green indicator light is on again, it indicates that the
generator set is operating normally.
4.2.4 When the green indicator light is off and the red indicator light
flashes once every 3s, it indicates that the power input of the generator set
is insufficient. Please turn off the generator set, maintain the air filter, spark
plug and carburetor before using it again. Or reduce the load power and
then gently touch the reset button. When the green indicator light is on
again, it indicates that the generator set is operating normally.
NOTE: When using the electrical equipment with high starting
current (like compressors and sinking pumps,etc.), the overload
indicator may flash for few seconds, which is a normal phenomenon,
because the inverter is controlled according to the current, as long as
the duration does not reach the protection time, the equipment will
return to normal after successful operation.
4.3 Running Indicator Light (Green)
The Running indicator is on when the
engine starts and outputs normally.
When the red indicator light flashes and
the green indicator light remains on constantly,
it indicates that the generator set has
exceeded the rated load. Please refer to 4.2.1 to solve this problem. When
the green indicator light is off and the red indicator light flashes, please
refer to 4.2.2~4.2.4 to solve this problem.
background
14
4.4 Energy-Saving Switch
4.4.1 ON
When the switch is in the "ON" position, the energy-saving device
controls the engine speed according to the load it is connected to, resulting
in better fuel consumption and low noise.
4.4.2
OFF
When the energy-saving switch is in the "OFF"
position, the engine runs at rated speed regardless of
whether the load is connected.
Tips: When using devices such as air compressors or sinking
pumps, the ECO must be turned off as a large starting current is
required.
4.5 Ground Terminal
The ground terminal is connected to the ground wire to prevent
electric shock.When electrical equipment is grounded, the generator must
be grounded.
Ground terminal
background
15
5. Preparations
5.1 Fuel
Fuel is flammable and toxic. Please read the safety instructions
carefully before refueling (see page 6 for details).
Do not fill the fuel tank too full, otherwise, the fuel will overflow
when the tank gets warm.
After refueling, confirm that the fuel tank cap has been tightened.
After refueling, wipe the residual gasoline with a clean, soft cloth to
avoid damaging the plastic shell.
Do use unleaded gasoline, because leaded gasoline can seriously
damage the engine's internal parts.
Recommended fuel: Unleaded gasoline
Loosen
Fuel tank cap
Tighten
Full Empty
Fuel gauge
background
16
5.2 Oil
The generator was delivered without engine oil. Do not start the
generator without sufficient engine oil.
5.2.1 Please place the generator on a horizontal place.
5.2.2 Turn the knob
to the ON position and remove the oil
maintenance door
.
5.2.3 Remove the oil dipstick .
5.2.4 Inject the specified amount of recommended oil and tighten the
oil dipstick.
5.2.5 Restore the oil maintenance door and turn the knob to the OFF
position.
Recommended engine oil: SAE 10W-30.
Recommended grade of engine oil: API standard SJ type or higher
grade.
1
background
17
5.3 AC Circuit Breaker Protection
Overload current can automatically turn off the breaker protector. Load
short circuit and overload should be avoided. If the circuit breaker is
automatically turned off, be sure to check the load condition before
pressing it to the ON position.
5.4 Ground Terminal
Ground terminal is a special terminal used to ground the whole
generator well.
6. Generator Usage
Applicable temperature: -5 ~ 40.
Applicable humidity: below 95%.
Applicable altitude: the area below 1000 meters (Drop the power or
contact the dealer to adjust the carburetor for use in the area above 1000
meters).
6.1 Connect Household Electrical Equipment
After connecting the household electrical equipment to the
generator, carefully check whether the electrical connection is safe
AC Circuit Breaker
Protection
Ground Termin
al
background
18
and reliable. If there is any incorrect electrical connection, it may
cause damage, combustion or fire to the generator.
When connecting the generator to the household power grid as a
backup power , it should be operated by a specialist electrician or
someone familiar with electricity.
Generator without ATS (Automatic Transfer Switch) function
shall not be directly connected to the household power grid.
6.2 Generator Ground
To prevent inferior electrical appliances from being electrocuted or the
generator from being damaged due to incorrect use of electrical equipment,
it is recommended to ground the generator with high-quality insulated
wires.
Ground Terminal
background
19
6.3 Alternating Current
Make sure before starting the generator:
The total power of the load apparatus (the sum of resistive, capacitive
and inductive load) shall not exceed the rated power of the generator.
Overload will lead to generator flameout or greatly shorten the life of
the generator. If more than one load or electrical equipment is connected
to the generator set, remember that the one with the highest starting load is
connected first, and the one with the lowest starting current is connected
last.
background
20
In general, capacitive and inductive load, especially motor drive device,
produce a large starting current when starting up.The following table is for
your reference when you connect these electrical appliances to the
generator set.
Type
Wattage
Typical
Equipment
example
Start
Rated
Device
Start
Rated
Incandescent
Lamp
Heating
Apparatus
X1
X1
100W
100VA
(W)
100VA
(W)
Fluorescent
Lamp
X2
X1.5
40W
80VA
(W)
60VA
(W)
Electromotor
Drive Device
X3-5
X2
150W
450-750VA
(W)
300VA
(W)
6.4 Used at high altitudes
At high altitudes, a standard carburetor can over-concentrate the
mixture gases of the engine, reduce power output and increase fuel
consumption. The performance of gasoline engines can be improved by
replacing the carburetor with a slightly smaller main injector or by adjusting
the adjusting screw. If you often use the generator at an altitude of more
than 1000 meters, you can buy special high-altitude parts to replace for
use. Otherwise, the load power should be reduced to use the generator.
Even with the right carburetor, every 300 meters increase in altitude,
the power of a gasoline engine will decrease by approximately 3.5%.
background
21
Without the replacement of a suitable carburetor, this decline would be
even greater.
If carburetors suitable for high-altitude use are equipped on
gasoline engines for low-altitude use, the overly thin mixture will
cause a decrease in the output power of the gasoline engine,
overheating and even serious damage.
6.5 Parallel Operation
Connect two same model generators with special PARALLEL KIT.
Make sure the ECO switch is in the same position on both generators.
All electric devices should be turned OFF and disconnected from
generators prior to starting generator engines.
Starting the generator, make sure the green output indicator light comes
on for each generator.
When engines have stabilized, plug in electric device to AC receptacle
and turn on first load.
Allow generator output to stabilize (engine and attached devices run
evenly) before plugging in the next load.
6.6 Rated Power in Parallel Operation
The parallel power shall not exceed: 9kW. For continuous operation,
do not exceed the rated output.
Note:
Only connect electric devices to the generator that are in good
working order and do not exceed the rated power supply of the
parallel generators or the desired receptacle.
A faulty appliance or power cord can create an electric shock. Do not
background
22
use electric devices that have a damaged cord or plug.
If an appliance begins to operate abnormally, becomes sluggish, or
stalls, turn it off and disconnect it immediately. The appliance may have
a fault, or its rated load capacity may exceed the generator’s power
supply.
To avoid damage to generator or electric device, do not connect a load
to the generator if its electrical rating exceeds that of the receptacle.
Never connect generators that are different models.
The parallel cable must be removed if operating only one generator.
Never disconnect or remove the parallel operation cable while generator
is still running.
7. Start the Generator
Disconnect the electrical equipment from the alternator's AC socket
before starting the engine.
For initial use (long unused, start after gasoline is used up), turn the start
switch to "ON" position for 10 to 20 seconds before starting, so that
gasoline can enter the engine carburetor.
It is strictly forbidden to use in indoor and closed environment.
7.1 Recoil Start
7.1.1 Remove all loads from the output end.
7.1.2 Turn the start switch to the CHOKE position.
7.1.3 Press the AC circuit breaker protector to the OFF position.
background
23
7.1.4 Gently pull the starting handle up until resistance is felt and pull it
out quickly.
7.1.5 When the generator is started, turn the start switch to the RUN
position.
7.1.6 Press the AC circuit breaker protector to the ON position before
the electrical load can be used.
When start the engine in the hot condition and fail to start normally
according to the above method, turn the start switch to RUN position and
start it again.
Do not allow the starting handle to rebound and retract automatically to
avoid damage to the shell. Slowly put the starting handle back.
8. Stop the Generator
8.1 Turn off and disconnect all electrical appliances.
8.2 Turn the ECO energy-saving switch to "OFF".
8.3 Turn off the AC circuit breaker protector.
8.4 Turn the start switch to the "OFF" position.
If you need to stop the generator in an emergency, put the generator
switch in the "OFF" position.
Recoil Start Handle
Start Switch
CHOKE
RUN
background
24
9. Maintenance
Good maintenance is the best guarantee to achieve safe, economic
and zero-fault operation. It also contributes to the environment protection.
To keep the engine in good condition, you must check and maintain it
regularly. Please follow the schedule below.
Maintenance Period
Item
Every
time
First
time in 1
month or
20 hours
after use
Every
three
months
or every
50 hours
Every
Year or
300
hours
after
use
Engine Oil
Check-Add
Replace
Reducer Gear Oil
(if equipped)
Check Oil Level
Replace
Air Filter
Elements
Check
Clean
Replace
Sedimentation
Cup (if equipped)
Clean
Spark Plug
Clean-Adjust
Spark Arrester
Clean
Idling(if
equipped)**
Check-Adjust
Valve Lash**
Check-Adjust
background
25
If it often works at high temperatures or under high loads, the engine
oil should be changed every 10 hours.
If it often works in a dusty or harsh environment, the air filter element
should be cleaned every 10 hours. If necessary, the air filter element
should be replaced every 25 hours.
The inspection cycle and time should be maintained on a first-come,
first-served basis.
If the maintenance period expired, the maintenance should be
carried out according to the form above as soon as possible.
Please stop the machine before carrying out any maintenance. The
engine should be placed in a horizontal position. To prevent the engine
from starting, separate the spark plug cap from the spark plug.
Do not use it indoors or in poorly ventilated places such as tunnels and
caves, and make sure that the working area is well ventilated. Exhaust gas
from engine contains toxic gas carbon monoxide, which can cause shock,
loss of consciousness and even death when inhaled.
Fuel Tank and
Fuel Filter **
Clean
Fuel Pipe
Check
Every two years (Replace if necessary)
Cylinder Head,
Piston
Eliminate
carbon depositio
n
Displacement <225cc, every 125 hours;
Displacement 225cc, every 250 hours.
*These items should be replaced if necessary.
**These items shall be maintained by the authorized dealer of our company
unless the User has the appropriate tools and maintenance capabilities.
background
26
9.1 Change Oil
Letting the gasoline engine start before draining the engine oil can
ensure that the oil is drained quickly and cleanly.
9.1.1 Remove the oil dipstick. Unscrew the oil drain bolt and drain oil.
9.1.2 Install the oil drain bolt and tighten it.
9.1.3 Add oil and check the oil level.
9.1.4 Install the oil dipstick.
Long-term and frequent skin contact with engine oil may lead to skin
cancer. Although this is not inevitable, it is recommended to wash the skin
exposed to engine oil immediately and thoroughly with soap and water.
From the perspective of environmental protection, please properly
dispose of the used engine oil after use. We strongly recommend that you
put the waste engine oil in a sealed container and send it to the local
service station or waste oil recovery center. Remember: do not throw it into
a garbage or drop it on the ground or in a ditch.
9.2 Maintain the Air Filter
A dirty air filter will affect the flow of air into the carburetor. To prevent
carburetor malfunctions, please maintain the air filter regularly. If used in
dusty environment, it should be maintained more frequently.
Cleaning the filter element with gasoline or flammable solvents may
Oil dipstick
Oil drain bolt
Top level
Bottom level
background
27
cause fire or explosion. Please use soapy water or non flammable solvent
to clean the filter element.
It is strictly forbidden to start the generator without installing an
air filter, otherwise it will cause rapid wear and tear of the engine.
9.2.1 Open the connecting button of the air filter cover and remove the
air filter cover. Check the air filter element to ensure it is intact and clean.
9.2.2 If the foam filter element gets dirty, please clean it. It can be
washed in hot water with household detergent, or in non-flammable or high
flash point solvents. Then rinse it with clean water and squeeze, and drop
a few drops of engine oil and squeeze evenly.
9.2.3 Install the filter element and cover the air filter.
9.3 Spark Plug
Please replace the spark plug in accordance with the original
specificationF7TC/ F7RTC
9.3.1 Remove the cover of the spark plug.
9.3.2 Remove the spark plug with the socket wrench.
9.3.3 Inspect whether the spark plug insulator is damaged or not. Replace
the spark plug if it is damaged.
Filter element
Air filter cover
Locking clamp
background
28
9.3.4 Measure the spark plug clearance with a thickness gauge, and bend
the side electrodes to adjust the clearance. The clearance should be
guaranteed within 0.70-0.80mm.
9.3.5 Inspect whether the spark plug gasket is in good condition.
9.3.6 Install the spark plug, and tighten it with the socket wrenchpress the
spark plug gasket and cover the spark plug cap tightly.
Please use the spark plug with proper calorific value.
9.4 Spark Arrester
The spark arrester must be maintained for every 100 hours of engine
operation.
9.4.1 Loosen the screws in the muffler cover and take off the
maintenance cover.
9.4.2 When the muffler is cooled, loosen the screws from the muffler
outlet and take off the spark arrester.
9.4.3 Use a brush to clean the carbon deposits on the spark arrester. If
the spark arrester is damaged, and replace it.
9.4.4 Re-install the spark arrester.
background
29
10. Storage
In order to avoid burning or fire caused by contact with
high-temperature parts of the generator, the generator must be cooled
before being packaged and stored.
Please ensure the storage area is clean and dry if long-term storage is
needed.
10.1 Drain the the fuel tank completely. Clean the fuel filter screen,
O-ring seal and sedimentation cup before reinstalling them. Unscrew the
carburetor's drain bolt, drain all the fuel from the carburetor, then reinstall it
and tighten the carburetor's drain bolt.
Under normal circumstances, gasoline is flammable and
explosive. Please drain the fuel in a well-ventilated area after the
machine stops. Smoking and open flames are strictly prohibited
during the process of draining fuel.
10.2 Unscrew the oil dipstick, unscrew the oil drain bolt on the
crankcase, and drain the oil from the crankcase completely. Then tighten
the oil drain bolt and fill with new oil to the upper limit, and install the oil
dipstick properly.
10.3 Remove the spark plug and add a tablespoon of clean engine oil
into the combustion chamber. Rotate the crankshaft several times to
distribute the oil throughout. Install the spark plug again.
10.4 Gently pull the start handle until you feel resistance to keep both
the intake and exhaust valves closed.
10.5 Place the generator set in a clean, cool, and dry area.
background
30
11. Troubleshooting
When the engine cannot start:
When it shows no voltage:
Yes
No
No
Check if there is any fuel
in the fuel tank?
Check if there is enough
engine oil in the crankcase?
Add oil
No
Add fuel
Yes
Check if there is any fuel in
the carburetor?
Check if the spark plug is in
good condition?
No
Ask the authorized
repair center for
service
Change the
spark plug
No
Yes
Check and clean
the carburetor
sedimentation cup
Yes
Ask the authorized repair
center for service
Is the circuit breaker
protector turned on?
Yes
Turn on the circuit
breaker protector
Check if there are any
faults with the electrical
components?
No
No
Ask the authorized
repair center for service
Change the electrical
components
Yes
background
31
12. Circuit Diagram
According to different configurations, the factory will make
corresponding adjustments. Subject to change without prior notice
background
32
13. Parameter
Gasoline
engine
Items
EDOG15
Engine type
Single cylinder, four-stroke, air-cooled
Displacement(cc)
223
Ignition system
Integrated digital ignition
Start mode
Recoil start
Oil capacity(L)
0.65
Generator
set
Tank capacity (L)
13
Fuel type
Unleaded gasoline
Frequency (Hz)
60
Phase
Single phase
Voltage (V)
120
Rated power(kW)
5.5
Max. power (kW)
7.0
DC output
12V/8.3A
Length(mm)
605
Width(mm)
430
Height(mm)
560
background
33
14. SERVICE INFORMATION
If you are not entirely satisfied with your purchase, please feel free to
contact us using the following steps:
1. Go to Your Orders.
2. Find your order in the list.
3. Select Problem with order.
4. Choose your topic from list displayed.
5. Select Contact seller.
6. You can also contact us via email, our email:
background
EMISSION CONTROL SYSTEM WARRANTY STATEMENT
YOUR WARRANTY RIGHTS AND OBLIGATIONS
The U. S. EPA and Shenzhen enfuni Technology Co., Ltd are pleased to explain the
emissions control system warranty on your model year 2026 and later small off-road
engine and equipment (equipment).
New equipment must be designed, built and equipped to meet the stringent anti-smog standards.
Shenzhen enfuni Technology Co., Ltd must warranty the emission control system on your equipment for
the period of time listed below, provided there has been no abuse, neglect or improper maintenance of
your equipment.
Your emission control system may include parts such as the carburetor, air cleaner, ignition system,
exhaust system, and other associated emission-related components.
Where a warrantable condition exists, Shenzhen enfuni Technology Co., Ltd will repair your equipment at
no cost to your including diagnosis, parts and labor.
MANUFACTURER’S WARRANTY COVERAGE
This emissions control system is warranted for two years. If any emission-related part on your equipment
is defective, the part will be repaired or replaced by Shenzhen enfuni Technology Co., Ltd.
OWNER’S WARRANTY RESPONSIBILITIES
As the equipment owner, you are responsible for the performance of the required maintenance listed in
your Owner’s Manual. Shenzhen enfuni Technology Co., Ltd recommends that you retain all your receipts
covering maintenances on your equipment, but Shenzhen enfuni Technology Co., Ltd cannot deny
warranty solely for the lack of receipts or for your failure to ensure the performance to all scheduled
maintenance.
As the equipment owner, you should however be aware that Shenzhen enfuni Technology Co., Ltd may
deny your warranty coverage if your equipment or part has failed due to abuse, neglect, improper
maintenance or unapproved modifications.
You are responsible for presenting your equipment to an Authorized Shenzhen enfuni
Technology Co., Ltd Service Dealer as soon as a problem exists. The warranted repairs
should be completed in a reasonable amount of time, not to exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities, you should contact:
Company: Windrider Tech Co., Ltd.
Contact PersonAustin
Tel.: 4696597752
Add.: 2707 Realty Road STE 100 Carrollton Texas 75006
background
DEFECTS WARRANTY REQUIREMENTS
Shenzhen enfuni Technology Co., Ltd warrants to the ultimate purchaser and each subsequent purchaser
that the equipment is designed, built and equipped so as to conform with all applicable regulations; and
free from defects in materials and workmanship that cause the failure of a warranted part, and is identical
in all material respects to that part as described in the application for certification.
The warranty period begins on the date the equipment is delivered to an ultimate purchaser or first placed
into service. Subject to certain conditions and exclusions as stated below, the warranty on emission-related
parts is as follows:
1.
Any warranted part that is not scheduled for replacement as required maintenance in the written
instructions supplied is warranted for the warranty period stated above. If the part fails during the period of
warranty coverage, the part will be repaired or replaced by Shenzhen enfuni Technology Co., Ltd
according to subsection (4) below. Any such part repaired or replaced under warranty will be warranted for
the remainder of the period.
2.
Any warranted part that is scheduled only for regular inspection in the written instructions supplied is
warranted for the warranty period stated above. Any such part repaired or replaced under warranty will be
warranted for the remaining warranty period.
3.
Any warranted part that is scheduled for replacement as required maintenance in the written instructions
supplied is warranted for the period of time before the first scheduled replacement date for that part. If the
part fails before the first scheduled replacement, the part will be repaired or replaced by Shenzhen enfuni
Technology Co., Ltd according to subsection (4) below. Any such part repaired or replaced under warranty
will be warranted for the remainder of the period prior to the first scheduled replacement point for the part.
4.
Repair or replacement of any warranted part under the warranty provisions herein must be performed at a
warranty station at no charge to the owner.
5.
Notwithstanding the provisions herein, warranty services or repairs will be provided at all of our distribution
centers that are franchised to service the subject engines or equipment.
6.
The equipment owner will not be charged for diagnostic labor that is directly associated with diagnosis of a
defective, emission-related warranted part, provided that such diagnostic work is performed at a warranty
station.
7.
Shenzhen enfuni Technology Co., Ltd is liable for damages to other engine or equipment components
proximately caused by a failure under warranty of any warranted part.
8.
Throughout the equipment warranty period stated above, Shenzhen enfuni Technology Co., Ltd will
maintain a supply of warranted parts sufficient to meet the expected demand for such parts.
9.
Any replacement part may be used in the performance of any warranty maintenance or repairs and must
be provided without charge to the owner. Such use will not reduce the warranty obligations of Shenzhen
enfuni Technology Co., Ltd.
10.
Add-on or modified parts that are not exempted by the Air Resources Board may not be used. The use of
any non-exempted add-on or modified parts by the ultimate purchaser will be grounds for disallowing a
warranty claim. Shenzhen enfuni Technology Co., Ltd will not be liable to warrant failures of warranted
parts caused by the use of a non-exempted add-on or modified part.
background
WARRANTED PARTS
The repair or replacement of any warranted part otherwise eligible for warranty coverage may be
excluded from such warranty coverage if Shenzhen enfuni Technology Co., Ltd demonstrates that the
equipment has been abused, neglected, or improperly maintained, and that such abuse, neglect, or
improper maintenance was the direct cause of the need for repair or replacement of the part. That
notwithstanding, any adjustment of a component that has a factory installed, and properly operating,
adjustment limiting device is still eligible for warranty coverage. Further, the coverage under this
warranty extends only to parts that were present on the equipment purchased.
The following emission warranty parts are covered (if applicable):
1.
Air-induction system
. • Air cleaner
. • Intake manifold
2.
Fuel system
. • Cold start enrichment system (soft choke)
. • Carburetor and internal parts
. • Fuel Pump
. • Fuel Tank
3.
Ignition system
. • Spark plug(s)
. • Magneto Ignition System
4.
Exhaust systems
5.
Miscellaneous Items Used in Above System
. Vacuum, temperature , position, time sensitive valves and switches
. • Sensors
. • Electronic control units
6.
Evaporative Emissions Control
. • Fuel Cap.
. • Fuel Line.
. • Fuel Line Fittings.
. • Vapor Hoses.

Specifications

EFURDEN EDOG15 Questions and Answers

Questions and Answers

Related Products