Honda EB6500 Industrial Generator

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual
  • Owner's Manual EALC 1025774 - 9999999 - (English) Read Online | Download pdf
  • Owner's Manual AG, AN types (mfg on or after 4/1/23) EBLC 1522911 - 9999999 - (English) Download
  • Owner's Manual AG, AN types EBLC 1506199 - 1522910 - (English) Download
  • Owner's Manual EBLC 1019455 - 1506198 - (English) Download
  • Owner's Manual EALC 1020452 - 1025773 - (English) Download
  • Owner's Manual EALC 1000001 - 1020451 - (English) Download
  • Owner's Manual EBLC 1000001 - 1019454 - (English) Download
  • Owner's Manual EZCH 1002886 - 1006208 - (English) Download
  • Owner's Manual EZCH 1000001 - 1002885 - (English) Download
Other Documents
  • AC Receptacle Selection EALC 1000001 - 9999999 - (English) Download
  • Breather Heater Kit EALC 1000001 - 9999999 - (English) Download
User Service
  • Common replacement parts guide EALC 1000001 - 9999999 - (English) Download
Installation Instruction
  • Handle and Wheel Kit Installation EALC 1000001 - 9999999 - (English) Download
EB6500 photo

Owner's Manual EALC 1025774 - 9999999

This is the main product document for model EB6500. Additionally, the document applies to other Honda models: EB6500X1AN, EB6500X1AG

The file format is pdf, 75 pages, you can download this manual here .

background
background
Exhaust contains poisonous carbon monoxide gas that can build up
to dangerous levels in closed areas.
Breathing carbon monoxide can cause unconsciousness or death.
Never run the generator in a closed, or even partly closed area where
people may be present.
The generator is a potential source of electrical shock if misused. Do
not expose the generator to moisture, rain or snow. Do not let the
generator get wet, and do not operate it with wet hands.
Keep this owner’s manual handy so that you can refer to it at any time.
This owner’s manual is considered a permanent part of the generator
and should remain with the generator if resold.
The information and specifications included in this publication were in
effect at the time of approval for printing. Honda Motor Co., Ltd.
reserves the right, however, to discontinue or change specifications or
design at any time without notice and without incurring any obligation
whatever. No part of this publication may be reproduced without
written permission.
The engine exhaust from this product
contains chemicals known to the State
of California to cause cancer, birth
defects or other reproductive harm.
09/02/10 10:28:44 31Z22600_001
background
1
Congratulations on your selection of a Honda generator. We are
certain you will be pleased with your purchase of one of the finest
generators on the market.
We want to help you get the best results from your new generator and
to operate it safely. This manual contains the information on how to
do that; please read it carefully.
As you read this manual, you will find information preceded by a
symbol. That information is intended to help you avoid
damage to your generator, other property, or the environment.
We suggest you read the warranty policy to fully understand its
coverage and your responsibilities of ownership. The warranty policy
is a separate document that should have been given to you by your
dealer.
When your generator needs scheduled maintenance, keep in mind
that your Honda servicing dealer is specially trained in servicing
Honda generators. Your authorized Honda servicing dealer is
dedicated to your satisfaction and will be pleased to answer your
questions and concerns.
Best Wishes,
Honda Motor Co., Ltd.
09/02/10 10:28:51 31Z22600_002
background
−
−
−
−
−
−
2
A FEW WORDS ABOUT SAFETY
Safety Labels
Safety Messages
Safety Headings
Safety Section
Instructions
To help you make informed decisions about safety, we have provided
operating procedures and other information on labels and in this
manual. This information alerts you to potential hazards that could
hurt you or others.
Of course, it is not practical or possible to warn you about all the
hazards associated with operating or maintaining a generator. You
must use your own good judgement.
You will find important safety information in a variety of forms,
including:
on the generator.
These signal words mean:
be or if
you don’t follow instructions.
be or if
you don’t follow instructions.
be if you don’t follow
instructions.
Your safety and the safety of others are very important. And using
this generator safely is an important responsibility.
preceded by a safety alert symbol and one
of three signal words, DANGER, WARNING, or CAUTION.
such as
IMPORTANT SAFETY INFORMATION
.
such as
how to use this generator correctly and safely.
This entire book is filled with important safety information please
read it carefully.
You WILL KILLED SERIOUSLY HURT
You CAN KILLED SERIOUSLY HURT
You CAN HURT
GENERAT OR SAFET Y .
09/02/10 10:29:04 31Z22600_003
background
3
CONTENTS
..............................................................................GENERATOR SAFETY . 5
.......................................................................Safety Label Locations . 5
............................................................Important Safety Information . 6
..............................................................COMPONENT IDENTIFICATION . 8
..............................................................................................CONTROLS . 10
....................................................................................Engine Switch . 10
........................................................................................Starter Grip . 10
................................................................................Fuel Valve Lever . 11
..........................................................................................Choke Rod . 11
............................Voltage Selector Switch (Dual Voltage System) . 12
...............................................................................Ground Terminal . 12
..............................................................................Oil Alert
System . 13
......................................................................Auto Throttle
System . 13
...................................................................................Circuit Breaker . 14
................................................................................Circuit Protector . 15
...........................................Ground Fault Circuit Interrupter (GFCI) . 16
...................................................................................GENERATOR USE . 20
...............................Connections to a Building’s Electrical System . 20
..................................................................................Ground System .20
.......................................................................Special Requirements . 20
.................................................................................AC Applications . 21
.....................................................................................AC Operation . 22
...................................................................AC Receptacle Selection . 23
......................................................................Auto Throttle
System . 29
....................................................................High Altitude Operation . 30
.......................................................................PRE-OPERATION CHECK . 31
..........................................................................................Engine Oil . 31
............................................................................................Refueling . 32
....................................................................Fuel Recommendations . 33
..............................STARTING THE ENGINE/STOPPING THE ENGINE . 34
......................................................................................MAINTENANCE . 36
......................................................The Importance of Maintenance . 36
..........................................................................Maintenance Safety . 37
.....................................................................Maintenance Schedule . 38
............................................................................Engine Oil Change . 39
...........................................................................Air Cleaner Service . 40
...........................................................Fuel Sediment Cup Cleaning . 41
............................................................................Spark Plug Service . 42
............................................................Spark Arrester Maintenance . 43
09/02/10 10:29:09 31Z22600_004
background
4
................................................................................................STORAGE . 44
..........................................................................Storage Preparation . 44
...........................................................................................Cleaning . 44
...................................................................................................Fuel . 44
.........................................................................................Engine Oil . 47
.........................................................................Storage Precautions . 48
....................................................................Removal From Storage . 48
.....................................................................................TRANSPORTING . 49
.............................................................................TROUBLESHOOTING . 50
..................................................................TECHNICAL INFORMATION . 52
............................................Emission Control System Information . 52
.............................................................................................Air Index . 54
.................................................................................WIRING DIAGRAM . 55
....................................................................................SPECIFICATIONS . 57
..............................................................................................ASSEMBLY . 60
.................................................WARRANTY SERVICE INFORMATION . 68
.................................................DEALER LOCATOR INFORMATION . 68
............................................CUSTOMER SERVICE INFORMATION . 68
.....................................................................Honda PUBLICATIONS . 69
......................................................................................................INDEX . 70
09/02/10 10:29:13 31Z22600_005
background
5
GENERATOR SAFETY
SAFETY LABEL LOCATION
California type
Non-California type
These labels warn you of potential hazards that can cause serious
injury. Read them carefully.
If a label comes off or becomes hard to read, contact your Honda
generator dealer for a replacement.
09/02/25 16:55:17 31Z22600_006
background
6
Operator Responsibility
IMPORTANT SAFETY INFORMATION
Carbon Monoxide Hazards
Honda generators are designed to give safe and dependable service if
operated according to instructions. Read and understand this owner’s
manual before operating your generator. You can help prevent
accidents by being familiar with your generator’s controls and by
observing safe operating procedures.
Know how to stop the generator quickly in case of emergency.
Understand the use of all generator controls, output receptacles,
and connections.
Be sure that anyone who operates the generator receives proper
instruction. Do not let children operate the generator without
parental supervision.
Exhaust contains poisonous carbon monoxide, a colorless and
odorless gas. Breathing carbon monoxide can cause loss of
consciousness and may lead to death.
If you run the generator in a confined or even partly enclosed area,
the air you breathe could contain dangerous amount of exhaust gas.
Never run your generator inside a garage, house, or near open
windows or doors.
09/02/10 10:29:42 31Z22600_007
background
−
−
−
7
Electric Shock Hazards
Fire and Burn Hazards
The generator produces enough electric power to cause a serious
shock or electrocution if misused.
Using a generator or electrical appliance in wet conditions, such as
rain or snow, or near a pool or sprinkler system, or when your hands
are wet, could result in electrocution. Keep the generator dry.
Fuel vapors are extremely flammable and may ignite after the
engine has started. Make sure that any spilled fuel has been wiped
up before starting the generator.
Gasoline is extremely flammable and is explosive under certain
conditions. Do not smoke or allow flames or sparks where the
generator is refueled or where gasoline is stored. Refuel in a well-
ventilated area with the engine stopped.
The muffler becomes very hot during operation and remains hot for
a while after stopping the engine. Be careful not to touch the muffler
while it is hot. Let the engine cool before storing the generator
indoors.
Keep the generator at least 3 feet (1 meter) away from buildings
and other equipment during operation.
Do not enclose the generator in any structure.
Keep flammable materials away from the generator.
The exhaust system gets hot enough to ignite some materials.
Do not connect to a building’s electrical system unless an isolation
switch has been installed by a qualified electrician.
Do not connect to swimming pool equipment installed before
adoption of the 1965 national electric code.
If the generator is stored outdoors, unprotected from the weather,
check the ground-fault circuit Interrupter (GFCI), and all other
electrical components on the control panel, before each use.
Moisture or ice can cause a malfunction or short circuit in electrical
components that could result in electrocution.
09/02/10 10:29:52 31Z22600_008
background
−
*
*
8
COMPONENT IDENTIFICATION
CONTROL PANEL
CHOKE ROD
ENGINE SWITCH
CONTROL PANEL
AIR CLEANER
FUEL VALVE LEVER
ENGINE SERIAL NUMBER
GFCI TEST BUTTON
GFCI RESET BUTTON
AC CIRCUIT PROTECTORS
GROUND TERMINAL
CIRCUIT BREAKER
120 ONLY 120/240
VOLTAGE SELECTOR SWITCH
1
1: Except EB3800X
OIL FILLER CAP/DIPSTICK
OIL DRAIN PLUG
STARTER GRIP
AUTO THROTTLE
SWITCH
120/240V AC
RECEPTACLE
120V AC RECEPTACLES
09/02/25 16:55:24 31Z22600_009
background
9
FUEL TANK CAP
FUEL GAUGE
WHEEL
MUFFLER
STAND
SPARK PLUG CAP
TRANSPORT HANDLE
LIFTING HANGER
FRAME SERIAL NUMBER
Date of purchase:
Record the engine and frame serial numbers and date of purchase
for your future reference. Refer to these serial numbers when
ordering parts and when making technical or warranty inquiries (see
page ).
Frame serial number:
Engine serial number:
*
68
09/02/25 16:55:29 31Z22600_010
background
10
CONTROLS
Engine Switch
Starter Grip
Switch position:
OFF:
ON:
STARTER GRIP
ENGINE SWITCH
ON
OOFFFF
RECOIL STARTER
To start and stop the engine.
To start the engine, pull the starter grip lightly until resistance is felt,
and then pull briskly.
Do not allow the starter grip to snap back against the engine. Return it
gently to prevent damage to the starter.
To stop the engine.
To run the engine.
09/02/10 10:30:17 31Z22600_011
background
11
Fuel Valve Lever
Choke Rod
OPEN
CHOKE ROD
OFF
ON
FUEL VALVE LEVER
CCLLOOSSEEDD
The choke is used to provide an enriched fuel mixture when starting a
cold engine. It can be opened and closed by operating the choke rod
manually. Pull the rod out toward CLOSED to enrich the mixture for
cold starting.
The fuel valve is located between the fuel tank and carburetor. When
the valve lever is in the ON position, fuel is allowed to flow from the
fuel tank to the carburetor. Be sure to return the fuel valve lever to the
OFF position after stopping the engine.
09/02/10 10:30:23 31Z22600_012
background
12
Voltage Selector Switch (Dual Voltage System)
Ground Terminal
Switch Position
120/240V:
120V ONLY:
GROUND TERMINAL
VOLTAGE SELECTOR SWITCH
120V ONLY
120/240V
112200//224400VV
112200VV OONNLLYY
The voltage selector switch switches the main power carrying
windings of the generator to produce ‘‘120V ONLY’’ or ‘‘120/240V’’. If a
240V appliance is connected to the 4-prong receptacle, the switch
must be in the ‘‘120/240V’’ position. If only a 120V appliance is being
connected to any of the 120V 3-prong receptacles, select the ‘‘120V
ONLY’’ position.
ONLY the 120V receptacles can be used. Do not use the
120/240V receptacle in this position. The most power
will be available at the 30A 120V locking plug
receptacle.
The 120V and 120/240V receptacles can be used
simultaneously.
Before using the ground terminal, consult a qualified electrician,
electrical inspector, or local agency having jurisdiction for local codes
or ordinances that apply to the intended use of the generator.
The generator ground terminal is connected to the frame of the
generator, the metal non-current-carrying parts of the generator, and
the ground terminals of each receptacle.
09/02/10 10:30:33 31Z22600_013
background
13
Oil Alert System
Auto Throttle
System
Switch Position
AUTO:
OFF:
OFF
ON
OFF
ON
AUTO THROTTLE SWITCH
If the engine stops and will not restart, check the engine oil level (see
page ) before troubleshooting in other areas.
Recommended to minimize fuel consumption and further
reduce noise levels when no load is applied to the generator.
The Auto Throttle system does not operate.
Recommended to minimize warm-up time when the
generator is started and when starting a load with large start-
up power equipments.
The Oil Alert
system is designed to prevent engine damage caused
by an insufficient amount of oil in the crankcase. Before the oil level in
the crankcase can fall below a safe limit, the Oil Alert system will
automatically stop the engine (the engine switch will remain in the ON
position). The Oil Alert system should not take the place of checking
the oil level before each use.
The Auto Throttle
system automatically reduces engine speed when
all loads are turned off or disconnected. When appliances are turned
on or reconnected, the engine returns to the rated speed.
31
09/02/10 10:30:42 31Z22600_014
background
−
−
14
Circuit Breaker
GFCI RESET BUTTON
CIRCUIT BREAKER
ON
OFF
Check the following if the circuit breaker switches OFF automatically:
The circuit breaker will automatically switch OFF if there is a short
circuit or a significant overload of the generator at the receptacle, or if
the ground fault circuit interrupter (GFCI) detects a ground fault
current.
When the GFCI RESET button is extended (page 18):
The circuit breaker may be used to switch the generator power on or
off.
Check that the appliance is working properly and does not exceed
the rated load capacity of the circuit before switching the circuit
breaker ON again.
When the GFCI RESET button is not extended:
Unplug all appliances from the receptacles and check the
appliance for any defects as described in TROUBLESHOOTING
(page 50).
After making repairs, push the GFCI RESET button then turn the
circuit breaker ON.
09/02/10 10:30:51 31Z22600_015
background
*
*
15
Circuit Protector
CIRCUIT PROTECTORS
ON
OFF
1
1: Except EB3800X
The circuit protectors will automatically switch OFF if there is a short
circuit or a significant overload of the generator at the 20A 120V, 30A
120V locking plug, or 120/240V locking plug receptacle. If a circuit
protector switches OFF automatically, check that the appliance is
working properly and does not exceed the rated load capacity of the
circuit before resetting the circuit protector ON.
09/02/10 10:30:57 31Z22600_016
background
16
Using the generator in rain or snow or near water can lead to death
from electric shock. Keep the generator dry.
Ground Fault Circuit Interrupter (GFCI)
GFCI TEST BUTTON
GFCI RESET BUTTON CIRCUIT BREAKER
All receptacles on the generator are protected by a ground fault circuit
interrupter (GFCI) for protection against the shock hazard of ground
fault current. The GFCI has TEST and RESET buttons and is connected
to the circuit breaker.
An example of ground fault current is the current that would flow
through a person who is using an appliance with faulty insulation and,
at the same time, is in contact with an electrical ground such as a
plumbing fixture, wet floor, or earth.
The ground fault circuit interrupter will not protect against short
circuits or overloads. The circuit breaker in the control panel that
supplies power to the circuit provides that protection (refer to circuit
breaker on page ).14
09/02/10 10:31:03 31Z22600_017
background
17
Observe the following precautions to ensure proper GFCI operation
and to reduce shock hazards:
Use grounded 3-conductor extension cords, tools, and appliances,
or double-insulated tools and appliances.
Inspect cords and plugs, and replace if damaged.
Do not use cord lengths greater than 164 feet (50 meters), and do
not use multiple tools and appliances with built-in noise filters. Such
use may activate the GFCI and trip the circuit breaker.
09/02/10 10:31:08 31Z22600_018
background
18
Inspection:
You risk electric shock if you operate this generator with a faulty GFCI
(ground fault circuit interrupter).
Test GFCI before use.
If the GFCI fails testing, do not use your generator. Contact your
Honda dealer.
CIRCUIT BREAKER
GFCI RESET BUTTON GFCI TEST BUTTON
OFF
Always check GFCI operation before using the generator.
Unplug all tools and appliances from the generator.
Start the engine.
Turn the circuit breaker to the ON position.
Turn the Auto Throttle switch to the OFF position.
Press the GFCI TEST button. The RESET button should extend, and
the circuit breaker should switch to the OFF position.
If the GFCI and circuit breaker do not function as described, take the
generator to an authorized Honda generator dealer for repair.
1.
2.
3.
4.
5.
09/02/10 10:31:15 31Z22600_019
background
19
GFCI RESET BUTTON
CIRCUIT BREAKER
ON
Press the GFCI RESET button. The RESET button should stay in,
flush with its base plate.
With the RESET button in and engine running, turn the circuit
breaker to the ON position. The circuit breaker should remain in the
ON position. The circuit breaker will not remain in the ON position if
the RESET button is extended.
If the GFCI and circuit breaker do not function as described, take the
generator to an authorized Honda generator dealer for repair.
During generator use, if the GFCI RESET button extends and the circuit
breaker trips, this usually indicates a faulty power tool, appliance, or
cord.
If that occurs, perform test steps 1 through 6 to verify that the GFCI
and circuit breaker are in proper working order. If the GFCI and circuit
breaker test correctly, then you will know that the fault is in the power
tool, appliance, or cord. Repair or replace the faulty power tool,
appliance, or cord before further use.
6.
09/02/10 10:31:20 31Z22600_020
background
20
GENERATOR USE
Ground System
Special Requirements
Connections to a Building’s Electrical System
Improper connections to a building’s electrical system can allow
electrical current from the generator to backfeed into the utility lines.
Such backfeed may electrocute utility company workers or others
who contact the lines during a power outage, and the generator may
explode, burn, or cause fires when utility power is restored. Consult
the utility company or a qualified electrician.
There may be Federal or State Occupational Safety and Health
Administration (OSHA) regulations, local codes, or ordinances that
apply to the intended use of the generator. Please consult a qualified
electrician, electrical inspector, or the local agency having jurisdiction.
If the generator is used at a construction site, there may be
additional regulations that must be observed.
In some areas, generators are required to be registered with local
utility companies.
Honda portable generators have a system ground that connects
generator frame components to the ground terminals in the AC output
receptacles. The system ground is not connected to the AC neutral
wire. If the generator is tested by a receptacle tester, it will show the
same ground circuit condition as for a home receptacle.
Connections for standby power to a building’s electrical system must
be made by a qualified electrician. The connection must isolate the
generator power from utility power, and must comply with all
applicable laws and electrical codes. A transfer switch, which isolates
generator power from utility power, is available through authorized
Honda generator dealers.
09/02/10 10:31:29 31Z22600_021
background
21
AC Applications
Before connecting an appliance or power cord to the generator:
Make sure that it is in good working order. Faulty appliances or
power cords can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance,
and determine whether the problem is the appliance or the rated
load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not
exceed that of the generator. Never exceed the maximum power
rating of the generator. Power levels between rated and maximum
may be used for no more than 30 minutes.
Limit operation requiring maximum power to 30 minutes.
Maximum power is:
3.8 kVA
5.0 kVA
6.5 kVA
Substantial overloading will open the circuit breaker. Exceeding the
time limit for maximum power operation or slightly overloading the
generator may not switch the circuit breaker or circuit protector OFF,
but will shorten the service life of the generator.
For continuous operation (longer than 30 minutes), do not exceed the
rated power.
Rated power is:
The total power requirements (VA) of all appliances connected must
be considered. Appliance and power tool manufacturers usually list
rating information near the model number or serial number.
5.5 kVA
4.5 kVA
3.3 kVA
EB3800X:
EB5000X:
EB6500X:
EB3800X:
EB5000X:
EB6500X:
09/02/10 10:31:41 31Z22600_022
background
*
*
22
AC Operation
AC CIRCUIT BREAKER
VOLTAGE SELECTOR SWITCH
GFCI RESET BUTTON
AACC CCIIRRCCUUIITT PPRROOTTEECCTTOORRSS
1
1: Except EB3800X
Check GFCI operation before each use (see page 18 ).
Do not exceed the current limit specified for any one receptacle. If an
overloaded circuit causes the AC circuit breaker or circuit protector to
switch OFF, reduce the electrical load on the circuit, wait a few minutes
and then reset the circuit breaker or circuit protector.
Start the engine (see page ).
Turn the voltage selector switch to either position.
With the voltage selector switch in the ‘‘120/240V’’ position, you can
use the 120V and 120/240V receptacles simultaneously. If you are
NOT using the 120/240V receptacle, then select the ‘‘120V ONLY’’
position.
Make sure that the GFCI RESET button is pushed in (flush with its
base plate).
Switch ON the AC circuit breaker.
Plug in the appliance.
Be sure that all appliances are in good working order before
connecting them to the generator. If an appliance begins to operate
abnormally, becomes sluggish, or stops suddenly, turn off the ignition
switch lever immediately. Then disconnect the appliance and examine
it for signs of malfunction.
Most motorized appliances require more than their rated power for
startup.
1.
2.
3.
5.
4.
6.
34
09/02/10 10:31:54 31Z22600_023
background
#
○
○
○
○
23
AC Receptacle Selection
Power Producing Circuits
EB3800X:
120V/240V
POWER
CIRCUIT 1
POWER
CIRCUIT 2
POWER CIRCUIT 1
POWER CIRCUIT 2
120V ONLY
120V 30A
120V 20A (in total)
120V 20A (in total)
& 120/240V 20A
4B
4A
4A 4B
The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals, 4A and 4B.
This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
09/02/10 10:32:02 31Z22600_024
background
++
+
24
Voltage Selector Switch
120V ONLY Position
120V/240V Position
ReceptacleSwitch Position
Set of
Receptacles
Power Producing
Circuit
Total Current
Available
Available Power
The power available to each receptacle depends on the position of the
voltage selector switch.
When the voltage selector switch is in the 120V ONLY position, you
do not need to spread the load over the receptacles. You must,
however, make sure the load on any receptacle does not exceed its
available power shown in the preceding table and the total load does
not exceed 27.5 amps.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 13.8 amps.
1
2
3
4A
4B
1
2
3
4A-4B
120V ONLY
120V/240V
134B
24A
1
2
13.8A
13.8A
27.5A at 120V
20A at 120V
20A at 120V
20A at 120V
None
13.8A at 120V
13.8A at 120V
13.8A at 120V
13.8A at 240V
09/02/10 10:32:09 31Z22600_025
background
#
○
○
○○
25
Power Producing Circuits
EB5000X:
120V/240V
POWER
CIRCUIT 1
POWER
CIRCUIT 2
POWER CIRCUIT 1
POWER CIRCUIT 2
120V 30A
120V 20A (in total)
120V 20A (in total)
& 120/240V 30A
120V ONLY
4A 4B
4B
4A
This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals, 4A and 4B.
09/02/10 10:32:17 31Z22600_026
background
++
+
26
Voltage Selector Switch
120V ONLY Position
120V/240V Position
ReceptacleSwitch Position
Set of
Receptacles
Power Producing
Circuit
Available Power
Total Current
Available
The power available to each receptacle depends on the position of the
voltage selector switch.
When the voltage selector switch is in the 120V ONLY position, you
do not need to spread the load over the receptacles. You must,
however, make sure the load on any receptacle does not exceed its
available power shown in the preceding table and the total load does
not exceed 37.5 amps.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 18.8 amps.
1
2
3
4A
4B
1
2
3
4A-4B
120V ONLY
120V/240V
134B
24A
1
2
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
18.8A at 120V
18.8A at 120V
18.8A at 120V
18.8A at 240V
18.8A
18.8A
09/02/10 10:32:24 31Z22600_027
background
#
○
○
○○
27
Power Producing Circuits
EB6500X:
120V/240V
POWER
CIRCUIT 1
POWER
CIRCUIT 2
POWER CIRCUIT 1
POWER CIRCUIT 2
120V 30A
120V 20A (in total)
120V 20A (in total)
& 120/240V 30A
120V ONLY
4A 4B
4B
4A
This generator is equipped with two power generating circuits. When
the voltage selector switch is in the 120V/240V position, each of the
two power producing circuits supplies power to specific receptacles.
When the voltage selector switch is in the 120V ONLY position, the
power producing circuits operate in parallel, sharing the total load
connected to terminal 4A and receptacles 1, 2, and 3.
The control panel, shown below, has a voltage selector switch and
four receptacles. Receptacle 4, the 240-volt receptacle, has two
powered terminals, 4A and 4B.
09/02/10 10:32:34 31Z22600_028
background
++
+
28
Voltage Selector Switch
120V ONLY Position
120V/240V Position
ReceptacleSwitch Position
Set of
Receptacles
Power Producing
Circuit
Available Power
Total Current
Available
The power available to each receptacle depends on the position of the
voltage selector switch.
When the voltage selector switch is in the 120V ONLY position, you
do not need to spread the load over the receptacles. You must,
however, make sure the load on any receptacle does not exceed its
available power shown in the preceding table and the total load does
not exceed 45.8 amps.
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 22.9 amps.
1
2
3
4A
4B
1
2
3
4A-4B
120V ONLY
120V/240V
134B
24A
1
2
30A at 120V
20A at 120V
20A at 120V
30A at 120V
None
22.9A at 120V
20A at 120V
20A at 120V
22.9A at 240V
22.9A
22.9A
09/02/10 10:32:41 31Z22600_029
background
29
Auto Throttle System
OFF
ON
OFF
ON
AUTO THROTTLE SWITCH
With the switch in the AUTO position, engine speed is automatically
reduced when ALL loads are turned OFF or disconnected. When
appliances are turned ON or reconnected, the engine returns to rated
speed. In the OFF position, the Auto Throttle system does not operate.
Appliances with large start-up power demands may not allow the
engine to reach normal operating rpm when they are connected to the
generator. Push the Auto Throttle switch to the OFF position and
connect the appliance to the generator. If the engine still will not reach
normal operating speed, check that the appliance does not exceed the
rated load capacity of the generator.
To avoid extended warm-up periods, keep the switch OFF until the
engine reaches operating temperature.
The Auto Throttle system is not effective for use with appliances that
require only momentary power. If the tool or appliance will be turned
ON and OFF quickly, the Auto Throttle switch should be in the OFF
position.
The Auto Throttle system will not respond to electrical loads of less
than 1 ampere or intermittent loads such as a staple gun. Turn the
Auto Throttle switch to the OFF position to operate loads of less than 1
amp.
09/02/10 10:32:49 31Z22600_030
background
30
High Altitude Operation
At high altitude, the standard carburetor air/fuel mixture will be too
rich. Performance will decrease, and fuel consumption will increase. A
very rich mixture will also foul the spark plug and cause hard starting.
Operation at an altitude that differs from that at which this engine was
certified, for extended periods of time, may increase emissions.
Even with carburetor modification, engine horsepower will decrease
about 3.5% for each 1,000-foot (300-meter) increase in altitude. The ef-
fect of altitude on horsepower will be greater than this if no carburetor
modification is made.
High altitude performance can be improved by specific modifications
to the carburetor. If you always operate your generator at altitudes
above 5,000 feet (1,500 meters), have your dealer perform this
carburetor modification. This engine, when operated at high altitude
with the carburetor modifications for high altitude use, will meet each
emission standard throughout its useful life.
When the carburetor has been modified for high altitude operation,
the air/fuel mixture will be too lean for low altitude use. Operation at
altitudes below 5,000 feet (1,500 meters) with a modified carburetor
may cause the engine to overheat and result in serious engine damage.
For use at low altitudes, have your servicing dealer return the
carburetor to original factory specifications.
09/02/10 10:32:55 31Z22600_031
background
31
PRE-OPERATION CHECK
Engine Oil
UPPER LEVEL
OIL FILLER HOLE
AMBIENT TEMPERATURE
OIL FILLER CAP/DIPSTICK
ChecktheoillevelBEFORE
EACH USE with the generator on
a level surface and the engine
stopped.
Use 4-stroke motor oil that
meets or exceeds the
requirements for API service
category SJ or later (or
equivalent). Always check the
API SERVICE label on the oil
container to be sure it includes
the letters SJ or later (or
equivalent).
If the level is low, fill to the upper limit of the oil filler neck with the
recommended oil.
SAE 10W-30 is recommended for general, all-temperature use. Other
viscosities shown in the chart may be used when the average
temperature in your area is within the indicated range.
Remove the oil filler cap/dipstick and wipe the dipstick clean.
Check the oil level by inserting the dipstick into the filler neck
without screwing it in.
1.
2.
3.
09/02/10 10:33:06 31Z22600_032
background
32
Refueling
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when handling fuel.
Stop engine and keep heat, sparks, and flame away.
Refuel only outdoors.
Wipe up spills immediately.
FUEL GAUGE
FUEL TANK CAP
NON-CALIFORNIA TYPE CALIFORNIA TYPE
TETHER
UPPER LIMIT MARK
UPPER LIMIT MARK
Never refuel the engine inside a building where gasoline fumes may
reach flames or sparks. Keep gasoline away from appliance pilot lights,
barbecues, electric appliances, power tools, etc.
Spilled fuel is not only a fire hazard, it causes environmental damage.
Wipe up spills immediately.
With the engine stopped, check the fuel level gauge. Refill the fuel tank
if the fuel level is low.
Refuel in a well-ventilated area with the engine stopped. If the engine
has been running, allow it to cool first. Refuel carefully to avoid
spilling fuel. Do not fill above the upper limit mark.
09/02/10 10:33:16 31Z22600_033
background
33
Fuel Recommendations
Fuel can damage paint and plastic. Be careful not to spill fuel when
filling your fuel tank. Damage caused by spilled fuel is not covered
under warranty.
Engine damage or performance problems that result from using a fuel
with percentages of ethanol or methanol greater than shown above
are not covered under warranty.
Use of fuels with content of ethanol or methanol greater than shown
above may cause starting and/or performance problems. It may also
damage metal, rubber, and plastic parts of the fuel system.
You may use regular unleaded gasoline containing no more than 10%
ethanol (E10) or 5% methanol by volume. In addition, methanol must
contain cosolvents and corrosion inhibitors.
Never use stale or contaminated gasoline or an oil/gasoline mixture.
Avoid getting dirt or water in the fuel tank.
This engine is certified to operate on regular unleaded gasoline with a
pump octane rating of 86 or higher.
After refueling, reinstall the fuel tank cap securely.
09/02/10 10:33:24 31Z22600_034
background
34
STARTING THE ENGINE/STOPPING THE ENGINE
Starting the Engine
Exhaust contains poisonous carbon monoxide gas that can build up
to dangerous levels in closed areas.
Breathing carbon monoxide can cause unconsciousness or death.
Never run the generator in a closed, or even partly closed area where
people may be present.
For your safety, do not operate the generator in an enclosed area such
as a garage. Your generator’s exhaust contains poisonous carbon
monoxide gas that can collect rapidly in an enclosed area and cause
illness or death.
If you wish to use the Auto Throttle system, turn the Auto Throttle
switch to the AUTO position after the engine has warmed up for 2 or
3 minutes.
Push the choke rod to the OPEN position as the engine warms up.
Do not allow the starter grip to snap back against the engine. Return it
gently to prevent damage to the starter.
Pull the starter grip lightly until resistance is felt, then pull briskly.
Move the engine switch to the ON position.
Make sure the Auto Throttle switch is in the OFF position, or more
time will be required for warm up.
Pull the choke rod to the CLOSE position.
Turn the fuel valve lever to the ON position.
Make sure that the AC circuit breaker is in the OFF position. The
generator may be hard to start if a load is connected.
Perform the
PRE-OPERATION CHECK
(see page ).
To prevent a possible fire, keep the generator at least 3 feet (1 meter)
away from building walls and other equipment during operation. Do
not place flammable objects close to the engine.
Operating this generator less than 3 feet (1 meter) from a building or
other obstruction can cause overheating and damage the generator.
For proper cooling, allow at least 3 feet (1 meter) of empty space
above and around the generator.
Refer to
AC Operation
(see page ) for connecting loads to the
generator.
9.
8.
7.
6.
5.
3.
4.
2.
1. 31
22
09/02/10 10:33:40 31Z22600_035
background
35
Stopping the Engine
In normal use:
In an emergency:
To stop the engine in an emergency, move the engine switch to the
OFF position.
Turn the AC circuit breaker to the OFF position.
Move the engine switch to the OFF position.
Turn the fuel valve lever to the OFF position.
1.
2.
3.
09/02/10 10:33:46 31Z22600_036
background
36
MAINTENANCE
Maintenance, replacement, or repair of the emission control devices
and systems may be performed by any engine repair establishment or
individual, using parts that are ‘‘certified’’ to EPA standards.
The Importance of Maintenance
Improper maintenance, or failure to correct a problem before
operation, can cause a malfunction in which you can be seriously hurt
or killed.
Always follow the inspection and maintenance recommendations and
schedules in this owner’s manual.
Good maintenance is essential for safe, economical, and trouble free
operation. It will also help reduce air pollution.
To help you properly care for your generator, the following pages
include a maintenance schedule, routine inspection procedures, and
simple maintenance procedures using basic hand tools. Other service
tasks that are more difficult or require special tools are best handled
by professionals and are normally performed by a Honda technician or
other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If
you operate your generator under severe conditions, such as
sustained high-load or high-temperature operation, or use it in
unusually wet or dusty conditions, consult your servicing dealer for
recommendations applicable to your individual needs and use.
09/02/10 10:33:52 31Z22600_037
background
−
−
−
37
Safety Precautions
Maintenance Safety
Failure to properly follow maintenance instructions and precautions
can cause you to be seriously hurt or killed.
Always follow the procedures and precautions in the owner’s manual.
Carbon monoxide poisoning from engine exhaust.
Burns from hot parts.
Injury from moving parts.
Some of the most important safety precautions follow. However, we
cannot warn you of every conceivable hazard that can arise in
performing maintenance. Only you can decide whether or not you
should perform a given task.
Make sure the engine is off before you begin any maintenance or
repairs. This will eliminate several potential hazards:
Operate outside away from open windows or doors.
Let the engine and exhaust system cool before touching.
Do not run the engine unless instructed to do so.
Read the instructions before you begin, and make sure you have the
tools and skills required.
To reduce the possibility of fire or explosion, be careful when
working around gasoline. Use only a non-flammable solvent, not
gasoline, to clean parts. Keep cigarettes, sparks, and flames away
from all fuel-related parts.
Remember that your servicing dealer knows your generator best and
is fully equipped to maintain and repair it.
To ensure the best quality and reliability, use only new, Honda
Genuine parts or their equivalents for repair or replacement.
09/02/10 10:34:04 31Z22600_038
background
38
Maintenance Schedule
Performed at every indicated
month or operating hour interval,
whichever comes first.
ITEM
First
month
or
20 Hrs.
Every
3 months
or
50 Hrs.
(1)
Each
use
Engine oil
Air cleaner
GFCI
Canister
(California type)
Purge tube
(California type)
Charge tube
(California type)
Sediment cup
Spark plug
Spark arrester
Idle speed
Valve clearance
Combustion
chamber
Fuel tank and filter
Fuel tube
Failure to follow this maintenance schedule could result in non-warrantable failures.
For commercial use, log hours of operation to determine proper maintenance intervals.
These items should be serviced by an authorized Honda generator dealer, unless the owner
has the proper tools and is mechanically proficient. See the Honda Shop Manual.
Service more frequently when used in dusty areas.
Every 2 years (Replace if necessary)(2)
After every 500 Hrs.(2)
Every
year
or
300 Hrs.
(2)
(2)
Every
6 months
or
100 Hrs.
(2)
Check level
Change
Check
Clean
Check
Check
Check
Check
Clean
Check-adjust
Replace
Clean
Check-adjust
Check-adjust
Clean
Clean
Check
(1)
(2)
(3)
Every 2 years (2)
Every 2 years (2)
Every 2 years (2)
REGULAR SERVICE PERIOD (3)
09/02/10 10:34:19 31Z22600_039
background
39
Engine Oil Change
UPPER LEVEL
OILFILLER CAP/DIPSTICK
SEALING WASHER
OIL DRAIN PLUG
Drain the oil while the engine is warm to assure rapid and complete
draining.
Place a suitable container below the engine to catch the oil, then
remove the oil drain plug and sealing washer, remove the oil filler
cap/dipstick, and drain the oil.
Reinstall the oil drain plug and a new sealing washer. Tighten the
plug securely.
Refill with the recommended oil (see page ) and check the oil level.
Wash your hands with soap and water after handling used oil.
Improper disposal of engine oil can be harmful to the environment. If
you change your own oil, please dispose of it properly. Put it in a
sealed container, and take it to a recycling center. Do not discard it in a
trash bin, dump it on the ground, or pour it down a drain.
1.
2.
3. 31
09/02/10 10:34:29 31Z22600_040
background
40
Air Cleaner Service
AIR CLEANER COVER
ELEMENT
ELEMENT
• properly
hooked
• improperly
hooked
CLIP (2)
CLIP (2)
AIR CLEANER COVER
ELEMENT
A dirty air cleaner will restrict air flow to the carburetor. To prevent
carburetor malfunction, service the air cleaner regularly. Service more
frequently when operating the generator in extremely dusty areas.
Reinstall the air cleaner element and the cover.
Soak the air cleaner element in clean engine oil and squeeze out the
excess oil. The engine will smoke during initial startup if too much
oil is left in the air cleaner element.
Wash the air cleaner element in a solution of household detergent
and warm water, then rinse thoroughly, or wash in nonflammable or
high flashpoint solvent. Allow the air cleaner element to dry
thoroughly.
Operating the engine without an air filter or with a damaged air filter
will allow dirt to enter the engine, causing rapid engine wear. This type
of damage is not covered by the
Distributor’s Limited Warranty.
Unsnap the two air cleaner cover clips, remove the air cleaner cover,
and remove the element.
1.
2.
3.
4.
09/02/10 10:34:42 31Z22600_041
background
41
Fuel Sediment Cup Cleaning
SEDIMENT CUP
FUEL FILTER
FUEL VALVE LEVER
O-RING
(Replace)
OOFFFF
The sediment cup prevents dirt or water that may be in the fuel tank
from entering the carburetor. If the engine has not been run for a long
time, the sediment cup should be cleaned.
Turn the fuel valve lever to the OFF position. Remove the sediment
cup, O-ring, and filter.
Turn the fuel valve lever ON and check for leaks.
Clean the sediment cup and filter in nonflammable or high flash
point solvent.
Reinstall the filter, new O-ring, and sediment cup.
1.
2.
3.
4.
09/02/10 10:34:50 31Z22600_042
background
−−
−
−
42
Recommended spark plugs:
Spark Plug Service
SPARK PLUG WRENCH
SPARK PLUG CAP
0.028 0.031 in
(0.7 0.8 mm)
SEALING WASHER
In order to service the spark plug, you will need a spark plug wrench
(commercially available).
BPR5ES (NGK)
Visually inspect the spark plug.
Discard it if the insulator is
cracked, chipped, or fouled.
To ensure proper engine operation, the spark plug must be properly
gapped and free of deposits.
An incorrect spark plug can cause engine damage.
If the engine has been running, let it to cool before servicing the spark
plug.
Remove the spark plug cap.
Clean any dirt from around the spark plug base.
Use a spark plug wrench to remove the spark plug.
Measure the spark plug electrode
gap with a wire-type feeler gauge.
Correct the gap, if necessary, by
carefullybendingtheside
electrode.
The gap should be:
0.028 0.031 in (0.7 0.8 mm)
W16EPR-U (DENSO)
1.
2.
3.
4.
5.
,
09/02/10 10:35:04 31Z22600_043
background
−
−
43
Spark Arrester Maintenance
SPARK ARRESTER
SPARK ARRESTER SCREEN
SCREW
Afterthesparkplugisseated,tightenwithasparkplugwrenchto
compress the washer.
If installing a new spark plug, tighten 1/2 turn after the spark plug
seats to compress the washer. If reinstalling a used spark plug,
tighten 1/8 1/4 turn after the spark plug seats to compress the
washer.
A loose spark plug can overheat and damage the engine.
Overtightening the spark plug can damage the threads in the
cylinder head.
If the generator has been running, the muffler will be very hot. Allow it
to cool before proceeding.
The spark arrester must be serviced every 100 hours to maintain its
efficiency.
Clean the spark arrester as follows:
Loosen the screw by the exhaust port of the muffler and remove the
spark arrester.
Use a brush to remove carbon deposits from the spark arrester
screen.
Inspect the screen for breaks or tears and replace it if necessary.
Install the spark arrester in the reverse order of removal.
Check that the spark plug sealing washer is in good condition, and
thread the spark plug in by hand to prevent cross-threading.
6.
7.
1.
2.
3.
09/02/10 10:35:18 31Z22600_044
background
44
STORAGE
Cleaning
Fuel
Storage Preparation
Proper storage preparation is essential for keeping your generator
trouble-free and looking good. The following steps will help to keep
rust and corrosion from impairing your generator’s function and
appearance, and will make the engine easier to start when you use the
generator again.
Wipe the generator with a moist cloth. After the generator has dried,
touch up any damaged paint, and coat other areas that may rust with a
light film of oil.
Depending on the region where you operate your equipment, fuel
formulations may deteriorate and oxidize rapidly. Fuel deterioration
and oxidation can occur in as little as 30 days and may cause damage
to the carburetor and/or fuel system. Please check with your servicing
dealer for local storage recommendations.
Gasoline will oxidize and deteriorate in storage. Old gasoline will
cause hard starting, and it leaves gum deposits that clog the fuel
system. If the gasoline in your generator deteriorates during storage,
you may need to have the carburetor and other fuel system
components serviced or replaced.
The length of time that gasoline can be left in your fuel tank and
carburetor without causing functional problems will vary with such
factors as gasoline blend, your storage temperatures, and whether the
fuel tank is partially or completely filled. The air in a partially filled fuel
tank promotes fuel deterioration. Very warm storage temperatures
accelerate fuel deterioration. Fuel deterioration problems may occur
within a few months, or even less if the gasoline was not fresh when
you filled the fuel tank.
The does not cover fuel system damage or
engine performance problems resulting from neglected storage
preparation.
You can extend fuel storage life by adding a gasoline stabilizer that is
formulated for that purpose, or you can avoid fuel deterioration
problems by draining the carburetor, sediment cup (if applicable) and/
or fuel tank.
Distributor’s Limited Warranty
09/02/10 10:35:29 31Z22600_045
background
45
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Service according to the table below:
Less than 1 month
1 to 2 months
2 months to 1 year
1 year or more
Use gasoline stabilizers that are formulated to extend storage
life.
Follow the manufacturer’s instructions for use.
Contact your authorized Honda generator dealer for stabilizer
recommendations.
No preparation required
Fill with fresh gasoline and add gasoline
stabilizer *.
Fill with fresh gasoline and add gasoline
stabilizer *.
Drain the carburetor float bowl (page 46 ).
Drain the fuel sediment cup (page 41 ).
Fill with fresh gasoline and add gasoline
stabilizer *.
Drain the carburetor float bowl (page 46 ).
Drain the fuel sediment cup (page 41 ).
Remove the spark plug. Put a teaspoon of
engine oil into the cylinder. Turn the engine
slowly with the pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil (page 39 ).
After removal from storage, drain the stored
gasoline into a suitable container, and fill
with fresh gasoline before starting.
*
09/02/10 10:35:34 31Z22600_046
background
46
Draining the Fuel Tank and Carburetor
Gasoline is highly flammable and explosive.
You can be burned or seriously injured when handling fuel.
Stop the engine and keep heat, sparks, and flame away.
Handle fuel only outdoors.
Wipe up spills immediately.
DRAIN SCREW
Drain the carburetor by loosening the drain screw. Drain the
gasoline into a suitable container.
Place a suitable gasoline container below the sediment cup, and use
a funnel to avoid spilling gasoline.
Remove the sediment cup (see page ), and then turn the fuel
valve lever to the ON position.
Allow the gasoline to drain completely, and then install the sediment
cup (see page ).
1.
2.
3.
4.
41
41
09/02/10 10:35:42 31Z22600_047
background
−
47
Engine Oil
STARTER GRIP
Align the notch on the starter pulley
with the hole at the top of recoil starter.
Reinstall the spark plug.
Pull the starter grip several times to distribute the oil in the cylinder.
Pour a teaspoon (5 10 cc) of clean engine oil into the cylinder.
Remove the spark plug (see page ).
Change the engine oil (see page ).
Slowly pull the starter grip until resistance is felt. At this point, the
piston is coming up on its compression stroke and both the intake
and exhaust valves are closed. Storing the engine in this position
will help to protect it from internal corrosion. Return the starter grip
gently.
1.
2.
3.
4.
5.
6.
39
42
09/02/10 10:35:50 31Z22600_048
background
48
Storage Precautions
Removal From Storage
If your generator will be stored with gasoline in the fuel tank and
carburetor, it is important to reduce the hazard of gasoline vapor
ignition.
Do not use sheet plastic as a dust cover. A nonporous cover will trap
moisture around the generator, promoting rust and corrosion.
With the engine and exhaust system cool, cover the generator to keep
out dust. A hot engine and exhaust system can ignite or melt some
materials.
Place the generator on a level surface. Tilting can cause fuel or oil
leakage.
Unless all fuel has been drained from the fuel tank, leave the fuel valve
in the OFF position to reduce the possibility of leakage.
If possible, avoid storage areas with high humidity, because that
promotes rust and corrosion.
Also avoid any area with a spark-producing electric motor, or where
power tools are operated.
Select a well ventilated storage area away from any appliance that
operates with a flame, such as a furnace, water heater, or clothes dryer.
If the fuel was drained during storage preparation, fill the tank with
fresh gasoline. If you keep a container of gasoline for refueling, be
sure that it contains only fresh gasoline. Gasoline oxidizes and
deteriorates over time, causing hard starting.
If the cylinder was coated with oil during storage preparation, the
engine may smoke briefly at startup. This is normal.
Check your generator as described in the
PRE-OPERATION CHECK
chapter of this manual (see page ).31
09/02/10 10:36:03 31Z22600_049
background
49
TRANSPORTING
Contact with a hot engine or exhaust system can cause serious burns
or fires. Let the engine cool before transporting or storing the
generator.
When transporting the generator, turn the engine switch and the fuel
valve OFF. Keep the generator level to prevent fuel spillage. Fuel vapor
or spilled fuel may ignite.
Take care not to drop or strike the generator when transporting. Do not
place heavy objects on the generator.
When transporting the generator by loading it on to a vehicle, secure
to the generator frame as shown.
09/02/25 16:55:34 31Z22600_050
background
50
TROUBLESHOOTING
When the engine will not start:
Is there fuel in the
tank?
Is there enough oil
in the engine?
Is the spark plug in
good condition?
Is the fuel reaching
the carburetor?
If the engine still
does not start, take
the generator to an
authorized Honda
generator dealer.
Refill the fuel tank.
(page 32)
Add the recom-
mended oil.
(page 31)
Readjust gap and
dry the spark plug.
Replace it if
necessary.
(page 42)
Clean the fuel
sediment cup.
(page 41)
Turn off the engine switch and loosen
the drain screw. (page 46)
Turn the fuel valve to ON. Fuel should
flow from the drain when the fuel valve
is turned ON.
To check:
YES
YES
YES
NO
NO
NO
YES
NO
1)
2)
09/02/10 10:36:17 31Z22600_051
background
〈〉
〈〉
51
No electricity at the AC receptacles:
Replace the electrical ap-
pliance or equipment.
Take the electrical ap-
pliance or equipment to an
electrical shop for repair.
Is the AC circuit breaker
ON?
When the GFCI RESET button is not extended
Unplug all appliances
and equipment, and in-
spect the GFCI operation.
(refer to page 18)
When the GFCI RESET button is extended
Replace the electrical ap-
pliance or equipment.
Take the electrical ap-
pliance or equipment to an
electrical shop for repair.
Is the AC circuit protector
ON?
Check the electrical ap-
pliance or equipment for
any defects.
Take the generator to an au-
thorized Honda generator
dealer.
Turn the AC circuit breaker
ON. (page 14)
Reset the circuit protector.
(page 15)
Take the generator to an au-
thorized Honda generator
dealer.
NO
YES
DEFECTS
NO DEFECTS
The GFCI RESET button
is extended again.
YES
NO
The GFCI RESET button
is not extended.
09/02/10 10:36:31 31Z22600_052
background
52
TECHNICAL INFORMATION
Source of Emissions
Emission Control System Information
The U.S. and California Clean Air Acts
Tampering and Altering
The combustion process produces carbon monoxide, oxides of
nitrogen, and hydrocarbons. Control of hydrocarbons and oxides of
nitrogen are very important because, under certain conditions, they
react to form photochemical smog when subjected to sunlight. Carbon
monoxide does not react in the same way, but it is toxic.
Honda utilizes appropriate air/fuel ratios and other emissions control
systems to reduce the emissions of carbon monoxide, oxides of
nitrogen, and hydrocarbons.
Additionally, Honda fuel systems utilize components and control
technologies to reduce evaporative emissions.
EPA and California regulations require all manufacturers to furnish
written instructions describing the operation and maintenance of
emission control systems.
The following instructions and procedures must be followed in order
to keep the emissions from your Honda engine within the emission
standards.
Tampering with or altering the emission control system may increase
emissions beyond the legal limit. Among those acts that constitute
tampering are:
Removal or alteration of any part of the intake, fuel, or exhaust
systems.
Altering or defeating the governor linkage or speed-adjusting
mechanism to cause the engine to operate outside its design
parameters.
09/02/10 10:36:42 31Z22600_053
background
53
Maintenance
Replacement Parts
Problems That May Affect Emissions
Follow the
Maintenance Schedule
on page . Remember that this
schedule is based on the assumption that your machine will be used
for its designed purpose. Sustained high-load or high-temperature
operation, or use in unusually wet or dusty conditions, will require
more frequent service.
If you are aware of any of the following symptoms, have your engine
inspected and repaired by your servicing dealer.
Hard starting or stalling after starting.
Rough idle.
Misfiring or backfiring under load.
Afterburning (backfiring).
Black exhaust smoke or high fuel consumption.
The emission control systems on your Honda engine were designed,
built, and certified to conform with applicable emission regulations.
We recommend the use of Honda Genuine parts whenever you have
maintenance done. These original-design replacement parts are
manufactured to the same standards as the original parts, so you can
be confident of their performance. The use of replacement parts that
are not of the original design and quality may impair the effectiveness
of your emission control system.
A manufacturer of an aftermarket part assumes the responsibility that
the part will not adversely affect emission performance. The
manufacturer or rebuilder of the part must certify that use of the part
will not result in a failure of the engine to comply with emission
regulations.
38
09/02/10 10:36:49 31Z22600_054
background
−
−
−
54
Air Index
(Models certified for sale in California)
Extended 300 hours (0 80 cc, inclusive)
500 hours (greater than 80 cc)
1,000 hours (225 cc and greater)
Intermediate 125 hours (0 80 cc, inclusive)
250 hours (greater than 80 cc)
Moderate 50 hours (0 80 cc, inclusive)
125 hours (greater than 80 cc)
Descriptive Term Applicable to Emission Durability Period
The durability description is intended to provide you with information
relating to the engine’s emission durability period. The descriptive
term indicates the useful life period for the engine’s emission control
system. See your
Emission Control System Warranty
for additional
information.
The bar graph is intended to provide you, our customer, the ability to
compare the emissions performance of available engines. The lower
the Air Index, the less pollution.
An Air Index Information label is applied to engines certified to an
emission durability time period in accordance with the requirements
of the California Air Resources Board.
09/02/10 10:37:01 31Z22600_055
background
55
WIRING DIAGRAM
EB3800X
09/02/10 10:37:23 31Z22600_056
background
56
EB5000X, EB6500X
09/02/10 10:37:39 31Z22600_057
background
×××
±
±
−−
57
SPECIFICATIONS
Dimensions
Engine
Generator
ITEM SPECIFICATION MAINTENANCE
Tuneup Specifications
EAJC
40.9 in (1,040 mm)
27.2 in (691 mm)
30.4 in (773 mm)
GX240
14.8 cu-in (242 cm
)
[2.9 2.3 in (73.0 58.0 mm)]
8.2 : 1
3,600 rpm
Forced air cooling
Transistorized magneto
Model
Type
Description code
Length
Width
Height
Dry mass [weight]
Model
Type
Engine type
Displacement
[Bore Stroke]
Compression ratio
Engine speed
Cooling system
Ignition system
Oil capacity
Fuel tank capacity
Spark plug
Model
Rated voltage
Rated frequency
AC output Rated current
Rated output
Maximum output
120/240 V
60 Hz
27.5/13.8 A
3.3 kVA
3.8 kVA
Spark plug gap
Valve clearance
Other specifications
IN: 0.15 0.02 mm (cold)
EX: 0.20 0.02 mm (cold)
No other adjustments needed.
185 lbs (84 kg)
California type
(AC type)
Non-California type
(AN type)
Non-California type
(AN type)
California type
(AC type)
BPR5ES (NGK) W16EPR-U (DENSO)
186.3 lbs (84.5 kg)
Refer to page 42
See your authorized
Honda dealer.
1.2 US qt (1.1 L)
6.21 US gal (23.5 L)
EB3800X
EB3800X
Specifications may vary according to the types, and are subject to
change without notice.
0.028 0.031 in (0.7 0.8 mm)
4-stroke, overhead valve, single cylinder
,
09/02/10 10:37:57 31Z22600_058
background
×
±
±
××
−−
58
Dimensions
Engine
Generator
ITEM MAINTENANCESPECIFICATION
Tuneup Specifications
Model
Type
Description code
Length
Width
Height
Dry mass [weight]
Model
Type
Engine type
Displacement
[Bore Stroke]
Compression ratio
Engine speed
Cooling system
Ignition system
Oil capacity
Fuel tank capacity
Spark plug
Model
Rated voltage
Rated frequency
AC output Rated current
Rated output
Maximum output
Spark plug gap
Valve clearance
Other specifications No other adjustments needed.
IN: 0.15 0.02 mm (cold)
EX: 0.20 0.02 mm (cold)
Refer to page 42
See your authorized
Honda dealer.
EAKC
41.3 in (1,049 mm)
27.2 in (691 mm)
30.4 in (773 mm)
GX340
20.6 cu-in (337 cm
)
[3.2 2.5 in (82.0 64.0 mm)]
8.0 : 1
3,600 rpm
Forced air cooling
Transistorized magneto
120/240 V
60 Hz
37.5/18.8 A
4.5 kVA
5.0 kVA
California type
(AC, ACH type)
Non-California type
(AN, ANH type)
215.6 lbs (97.8 kg) 214.5 lbs (97.3 kg)
Non-California type
(AN, ANH type)
BPR5ES (NGK) W16EPR-U (DENSO)
California type
(AC, ACH type)
1.2 US qt (1.1 L)
6.21 US gal (23.5 L)
EB5000X
EB5000X
Specifications may vary according to the types, and are subject to
change without notice.
0.028 0.031 in (0.7 0.8 mm)
4-stroke, overhead valve, single cylinder
,
09/02/10 10:38:13 31Z22600_059
background
×
±
±
××
−−
59
Dimensions
Engine
Generator
ITEM MAINTENANCESPECIFICATION
Tuneup Specifications
Model
Type
Description code
Length
Width
Height
Dry mass [weight]
Model
Type
Engine type
Displacement
[Bore Stroke]
Compression ratio
Engine speed
Cooling system
Ignition system
Oil capacity
Fuel tank capacity
Spark plug
Model
Rated voltage
Rated frequency
AC output Rated current
Rated output
Maximum output
Spark plug gap
Valve clearance
Other specifications No other adjustments needed.
IN: 0.15 0.02 mm (cold)
EX: 0.20 0.02 mm (cold)
Refer to page 42
See your authorized
Honda dealer.
EALC
8.0 : 1
3,600 rpm
Forced air cooling
Transistorized magneto
120/240 V
41.9 in (1,064 mm)
27.2 in (691 mm)
30.4 in (773 mm)
GX390
23.7 cu-in (389 cm
)
[3.5 2.5 in (88.0 64.0 mm)]
60 Hz
45.8/22.9 A
5.5 kVA
6.5 kVA
California type
(AC, ACH type)
BPR5ES (NGK)
California type
(AC, ACH type)
Non-California type
(AN, ANH type)
Non-California type
(AN, ANH type)
W16EPR-U (DENSO)
220.7 lbs (100.1 kg) 219.6 lbs (99.6 kg)
1.2 US qt (1.1 L)
6.21 US gal (23.5 L)
EB6500X
EB6500X
Specifications may vary according to the types, and are subject to
change without notice.
0.028 0.031 in (0.7 0.8 mm)
4-stroke, overhead valve, single cylinder
,
09/02/10 10:38:28 31Z22600_060
background
60
ASSEMBLY
The Importance of Proper Assembly
Improper assembly can cause an unsafe condition that can lead to
serious injury or death.
Follow the procedures and precautions in the assembly instructions
carefully.
Failure to properly follow instructions and precautions can cause you
to be seriously hurt or killed.
Follow the procedures and precautions in this manual carefully.
Proper assembly is essential to operator safety and the reliability of
the machine. Any error or oversight made by the person assembling
and servicing a unit can easily result in faulty operation, damage to the
machine, or injury to the operator.
Some of the most important safety precautions are given below.
However, we cannot warn you of every conceivable hazard that can
arise in performing this assembly. Only you can decide whether or not
you should perform a given task.
09/02/10 10:38:35 31Z22600_061
background
□
□
□
□
61
Important Safety Precautions
Carbon monoxide poisoning from engine exhaust.
Burns from hot parts.
Injury from moving parts.
Make sure you have a clear understanding of all basic shop safety
practices and that you are wearing appropriate clothing and safety
equipment. When performing this assembly, be especially careful of
the following:
Make sure the engine is off before you begin any maintenance or
repairs. This will help eliminate several potential hazards:
Read the instructions before you begin, and be sure you have
the tools and skills required to perform the tasks safely.
Operate outside away from open windows or doors.
Let the engine and exhaust system cool before touching.
Do not run the engine unless the instruction tells you to do so.
Even then, keep your hands, fingers, and clothing away. Do not
run the engine when any protective guard or shield is removed.
To reduce the possibility of a fire or explosion, be careful when
working around gasoline or batteries. Use only a non-flammable
solvent, not gasoline, to clean parts. Keep all cigarettes, sparks, and
flames away from all fuel-related parts.
09/02/10 10:38:42 31Z22600_062
background
×
×
62
Unpacking
Loose Parts (Wheel kit, hanger and handle)
Remove the generator and loose parts box from the carton.
Compare the loose parts with the inventory list below.
Check all loose parts against the following list. Contact your dealer if
any of the loose parts shown below are not included with your
generator.
Tools Required:
1.
2.
12 mm wrench (2), pliers
Ref. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
Qty.
2
1
1
1
1
1
2
1
2
16
2
2
4
Description
Wheel
Axle
Left upper handle assy
Right upper handle assy
Left handle bracket
Right handle bracket
Stand
Hanger
Hanger bracket
8 16 mm Flange bolt
20 mm Washer
4.0 28 mm Cotter pin
8 mm Flange nut
09/02/25 16:55:43 31Z22600_063
background
−− −
×
63
Hanger Kit Installation
TORQUE:
HANGER
HANGER
GENERATOR
SIDE
HANGER BRACKET (2)
8 16 mm FLANGE BOLT (4)
280 mm (11 in)
Position the hanger at the generator’s balance point as shown below.
Fit the end tabs of the hanger through the bracket slots, and bolt the
brackets to the hanger and tighten securely.
17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)
1.
2.
09/02/10 10:39:01 31Z22600_064
background
−− −
×
64
Handle Installation
TORQUE:
RIGHT HANDLE
BRACKET
LEFT HANDLE BRACKET
8 16 mm FLANGE BOLT (4)
LEFT UPPER HANDLE ASSY
RIGHT UPPER HANDLE ASSY
Install the right and left handles on the generator upper frame using
the brackets and 6 flange bolts.
17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)
09/02/10 10:39:06 31Z22600_065
background
×
×
−− −
×
×
×
65
Wheel Kit Installation
TORQUE:
AXLE
8 mm FLANGE NUT (4)
8 16 mm FLANGE BOLT (4)
GENERATOR
SIDE
8 16 mm FLANGE BOLT (4)
STAND (2)
LONGER
20 mm WASHER (2)
4.0 30 mm
COTTER PIN (2)
WHEEL (2)
Install the axle assembly on the generator using four 8 16 mm
flange bolts and 8 mm flange nuts.
Install the two stands on the under frame using four 8 16 mm
flange bolts.
17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)
Apply grease to the axle shaft as shown below, and install the two
wheels on the axle shaft using the washers and split pins.
1.
2.
3.
09/02/25 16:55:50 31Z22600_066
background
66
Engine Oil
WITHOUT OIL
Fuel
AMBIENT TEMPERATURE
OIL FILLER HOLE
UPPER LEVEL
OIL FILLER CAP/DIPSTICK
The generator is shipped
in the engine.
Place the generator on a level
surface. Add enough of the
recommended oil to bring the
oil level to the top of the oil
filler neck.
Refer to page .
Use a 4-stroke motor oil that
meets the requirements for
API service category SJ or
later (or equivalent).
Do not overfill the engine
with oil. If the engine is
overfilled, the excess oil may
get transferred to the air
cleaner housing and air filter.
SAE 10W-30 is recommended
for general, all-temperature
use. Other viscosities in the
chart may be used when the
temperature in your area is
within the indicated range.
32
09/02/10 10:39:25 31Z22600_067
background
67
BEFORE OPERATION
CONTROLS
GENERATOR USE
STARTING THE ENGINE
GENERATOR SAFETY
STOPPING THE ENGINE
Before using your generator, you should become familiar with
information contained in the following chapters and sections:
(page )
(page )
(page )
(page )
(page )
10
20
5
34
35
09/02/10 10:39:33 31Z22600_068
background
68
WARRANTY SERVICE INFORMATION
DEALER LOCATOR INFORMATION
CUSTOMER SERVICE INFORMATION
Model and serial number (see pages and )
Name of dealer who sold the generator to you
Name and address of dealer who services your generator
Date of purchase
Your name, address, and telephone number
A detailed description of the problem
When you write or call, please give us this information:
Servicing dealership personnel are trained professionals. They should
be able to answer most questions you may have. If you encounter a
problem that your dealer does not solve to your satisfaction, please
discuss it with the dealership’s management. The Service Manager or
General Manager can help. Almost all problems are solved in this way.
To find an authorized Honda Servicing Dealer anywhere in the United
States:
visit our web site:
www.hondapowerequipment.com/dealerlocator/
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
If you are dissatisfied with the decision made by the dealership’s
management, contact the Honda Power Equipment Customer
Relations Office. You can write to:
Or telephone: (770) 497-6400 8:30 am to 7:00 pm ET
89
09/02/10 10:39:44 31Z22600_069
background
69
Shop Manual
Parts Catalog
Accessories Catalog
Honda PUBLICATIONS
This manual covers complete maintenance and overhaul procedures.
It is intended to be used by a skilled technician.
Available through your Honda dealer or through Helm Inc. at 1 888-
292-5395 or visit www.hondapowerequipment.com
This manual provides complete, illustrated parts lists. Available
through your Honda dealer.
Your authorized Honda power equipment dealer offers a wide
selection of accessories (optional equipment) to make your generator
even more useful.
Visit www.hondapowerequipment.com
09/02/10 10:39:54 31Z22600_070
background
70
INDEX
..............................................................................................ASSEMBLY . 57
..............................................................COMPONENT IDENTIFICATION . 8
................................................................................................CONTENTS . 3
..............................................................................................CONTROLS . 10
......................................................................Auto Throttle
System . 13
..........................................................................................Choke Rod . 11
...................................................................................Circuit Breaker . 14
................................................................................Circuit Protector . 15
....................................................................................Engine Switch . 10
................................................................................Fuel Valve Lever . 11
...........................................Ground Fault Circuit Interrupter (GFCI) . 16
...............................................................................Ground Terminal . 12
..............................................................................Oil Alert
System . 13
........................................................................................Starter Grip . 10
............................Voltage Selector Switch (Dual Voltage System) . 12
..............................................................................GENERATOR SAFETY . 5
............................................................Important Safety Information . 6
.......................................................................Safety Label Locations . 5
...................................................................................GENERATOR USE . 20
.................................................................................AC Applications . 21
.....................................................................................AC Operation . 22
...................................................................AC Receptacle Selection . 23
......................................................................Auto Throttle
System . 29
...............................Connections to a Building’s Electrical System . 20
.................................................................................Ground System . 20
....................................................................High Altitude Operation . 30
.......................................................................Special Requirements . 20
......................................................................................MAINTENANCE . 36
...........................................................................Air Cleaner Service . 40
............................................................................Engine Oil Change . 39
...........................................................Fuel Sediment Cup Cleaning . 41
..........................................................................Maintenance Safety . 37
.....................................................................Maintenance Schedule . 38
............................................................Spark Arrester Maintenance . 43
............................................................................Spark Plug Service . 42
......................................................The Importance of Maintenance . 36
09/02/10 10:39:59 31Z22600_071
background
71
.......................................................................PRE-OPERATION CHECK . 31
..........................................................................................Engine Oil . 31
....................................................................Fuel Recommendations . 33
............................................................................................Refueling . 32
....................................................................................SPECIFICATIONS . 54
..............................STARTING THE ENGINE/STOPPING THE ENGINE . 34
................................................................................................STORAGE . 44
.........................................................................Storage Precautions . 48
..........................................................................Storage Preparation . 44
....................................................................Removal From Storage . 48
..................................................................TECHNICAL INFORMATION . 52
.............................................................................................Air Index . 54
............................................Emission Control System Information . 52
.....................................................................................TRANSPORTING . 49
.............................................................................TROUBLESHOOTING . 50
.................................................WARRANTY SERVICE INFORMATION . 68
............................................CUSTOMER SERVICE INFORMATION . 68
.................................................DEALER LOCATOR INFORMATION . 68
.....................................................................Honda PUBLICATIONS . 69
.................................................................................WIRING DIAGRAM . 55
09/02/10 10:40:02 31Z22600_072
background
72
MEMO
09/02/10 10:40:05 31Z22600_073
background
00X31Z226060

Specifications

Indexed Terms: Generator, Industrial

Honda EB6500 Questions and Answers

Questions and Answers

Related Products