Installation & Operating Instructions for the
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
Sicherheit information
1. To reduce the risk of an electrical blow, electricity on the
protec�ve switch or the safety box went out before star�ng.
2. All wiring must correspond to the NASI/NFPA 70-1999
Na�onal Electric Code and local electrical regula�ons. The
electrical installa�on must be carried out by a qualified and
approved electrician.
3. The connec�on box and support construc�on must be
assembled safely and 35 pounds (15.9 kilos) must be able
to transport reliably. Use only output boxes listed with
labeling
"Accepted for fans with a weight of £ 35 (15.9 kilos) or less."
4. The fan must be installed with a minimum distance of 2.1 m
(7 feet) from the posterior edge of the blades to the floor.
5. Do not operate the reverse switch if the fan blades are
moving. You have to turn off the fan and stop the blades
before reverse the direc�on of the blades.
6. Do not place objects on the road to blades.
7. To avoid lesions or damage to the fan and other objects, be
careful if you work on the fan or clean it.
8. Electrical diagrams only serve as a reference. The ligh�ng
rates that are not delivered with the fan must be listed and
marked with the valve model that will be installed for use.
The switches must be general use switches UL. Take into
account the instruc�ons for the appropriate installa�on
included in the ligh�ng rates and the switches.
9. A�er the electrical connec�ons have been made, the size
staircase must be turned up and carefully push to the plug
box. The cables must be distributed in such a way that the
ground connected driver and the device head are next to
the socket.
10.All fixing screws must be verified before installa�on and, if
necessary, followed.
WARNING: To reduce the risk of injury, blade brackets
cannot be folded during installa�on or a�er installa�on.
Do not put any object on the path of blades.
WARNING:
Remove rubber motor a�acks at the
bo�om of the fan before moun�ng the blades or try
the motor.
WARNING: To avoid the risk of a fire or an
electrical blow, this fan should not be used with a
semiconductor speed controller.
WARNING: To avoid a possible electric shock,
turn off the current in the main security box
before wiring. If you feel that you do not have
enough knowledge or experience in electrical
wiring, communicate with a license electrician.
WARNING: Electrical diagrams only serve as a
reference. The op�onal use of an ligh�ng rate must
be on the list and marked with this fan for use.
WARNING: To reduce the risk of fires, electrical
discharges or injuries, assemble the device in a
socket that with the inscrip�on accepted for fans
with a weight of £ 35) or less. It is marked and use
the screws supplied with the plug.
TECHNICAL INFORMATION
530173SQQSNDW
52W
Make sure that there is a space of at least 30 cm between the
fan’s blades and any wall or other obstacle with which they
could collide.It is important to note that the greater the
distance,the more efficient the airflow would be.
0,3m
1
Nominal voltage Nominal output (motor) light
SKU
110-120V AC
18W LED 3000/4000/6000K
110-120V AC
18W LED 3000/4000/6000K
530173SQQSNBW
110-120V AC 18W LED 3000/4000/6000K
530173SQQWO
52W
52W
Perimost Owner's Installation ,Manual

2
Installation & Operating Instructions for the
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
Fan-motor assembly
Mounting screw(2PCS)
Washer(2PCS)
Blade screw(7PCS)
Plastic wire nut(6PCS)
Blade 3PCS
Remote control (1 PC)
Perimost Owner's Installation ,Manual

3
Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
1
result in serious injury.
electrician install this fan.
screws & washers.
the blade to the nearest objects or walls.Secure
structure that is capable of carrying a load of at least 15.9kgs,with two long screws provided.
Ensure at least 30mm of the screws is threaded into the support.
2
for later use.
4
70%
70%
100%
100%
Washers
Outlet box
3
WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
X4
R E C E I V E R
L
N
L
N
FROM POWER SOURCE AC 110- 120 VOLT 60Hz 3.5AMPS.
OUTPUT
Black
Blue
White
Ground wire
Red
White
Black
Use plastic wire nuts
fan
supplied with the
Use plastic wire nuts
fan
supplied with the
White
Blue

4
Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
(WINTER TIME)
(SUMMER TIME)
-(Forward) A downward airflow creates a cooling effect.
This allows you to set your air condi�oner on a higher se�ng without affec�ng your comfort.
-(Reverse) A upward airflow moves warm air off the ceiling.
This allows you to set hea�ng unit on a lower se�ng without affec�ng your comfort.
The appropriate speed se�ngs for warm or cool weather depends on factors such as the room size,ceiling height, and number of fans.
The silde switch(XX) controls the direc�on of the blades: forward(switch le�) or reverse(switch right).
5
NOTE: Wait for the fan to stop before reversing the direc�on of the blade rota�on.
One blade at a �me,insert the blade into the slot through the motor and aligh the blade with the 2 holes.
Tighten screws securely.
Repeat for the remaining 2 blades.
Remove 3 screws from the motor, and then connect the connectors.
Install the light pan to the motor with 3 screws. Tighten screws securely.
6
6
7
Aligh groove in the light cover with ridge in the light pan.
Twist light cover clockwise un�l it is secure.
X3
X6
X3
X3
F
R

5
Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
6
6
Remote controller
INSTRUCTION OF INSTALLATION AND OPERATION
7. To Reduce the risk of shock, this fan must be installed
3. Electrical wire must meet all local and national
2. Do not use with solid state fans.
by removing fuse or switching off circuit breaker.
1. INSTALLING RECEIVER IN CEILING FAN
5. Maximum fan motor amps: 1.0.
6. Maximum light watts: 180 incandescent or ballast and LED.
4. Supply for fan must be 110/120 volt, 60Hz, 3.5A
1. WARNING: HIGH VOLTAGE! Disconnect power
Black receiver wire(TO MOTOR L)...Black fan wire
White receiver wire(TO MOTOR N)...White fan wire
White receiver wire(AC IN N)......White supply wire
Red/Black receiver wire(AC IN L)......Red/Black supply wire
supplied.
2.Remove ceiling fan canopy from the mounting bracket.
B. Installing receiver in fan
CONNECT TO
1. Remove power from the circuit.
CAUTION: Ceiling Angle Shall Not Exceed 30 Degrees,
For Mounting Controller. Models GA043
4.Make connections as follows, using the wire nuts
3.Disconnect existing wiring between ceiling fan
and Supply in electrical junction box.
Blue receiver wire(FOR LIGHT)...Blue light wire
(FIG.3)
ANTENNA PUT AT OUTSIDE
OF CANOPY BOX CAN GET
MORE OPERATION DISTANCE
LIGHT MUST KEEP AT THE
TURN ON POSITION
FAN MUST KEEP AT THE
HIGH SPEED POSITION
RECEIVER
CANOPY
FROM POWER SOURCE
AC 110~120 VOLT
60Hz 3.5AMPS.
.fanthewithsuppliednutsconnectingwireUse
(FIG.2)
RECEIVER
A.Safety precautions
with a wall switch/control.
CANOPY
WHITE
INPUT
RED/BLACK
ANT
b.Lay the brown antenna wire on top of the receiver,and put the receiver into the mounting bracket.
If other fans or supply wires are different color, have this unit installed by qualified licensed electrician.
d.Restore power.
c.Reinstall the canopy on the mounting bracket.
a.Push all connected wires up into junction box.
e.Install 1.5 volt battery. (To prevent damage to transmitter, remove the battery if not used for a long time).
f. Store the transmitter away from excessive heat or humidity.
g.This remote control unit is equipped with roll code combinations. In order to prevent possible interference from or to
other remote units such as garage door openers, car alarm or security system. If you find that your fan and light kit go on
and off without using your remote control, simply change the code combination in your transmitter and receiver
RECEIVER
electrical code requirements.
(FIG.1)
Models RE-018
ACN
INPUT
ACL
OUTPUT
TNA
RECEIVER
TNA
CODE
CODE
COM
N
R
A
NE
L
TRANSMITTER
OUTPUT
WHITE
WHITE
BLUE
BLUE
BLACK
BLACK

6
Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
6
6
authority to operate the equipment.
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital, pursuant to Part 15 or the FCC
After the 1# and 2# remote control transmitters have been successfully learned, turn on the power of the two ceiling fans. At this time,
e.Good battery in the transmitter?
d.Light kit switch turned on?
c.Fan manual speed control in highest position?
b.Receiver wired correctly?
a.Power to receiver?
3.TROUBLE SHOOTING GUIDE
the 1# transmitter and the 2# transmitter can be used separately for one ceiling fan.
And so on, only one ceiling fan is powered on each time the corresponding transmitter learns.
If there are two or more ceiling fans installed in the same house, in order to prevent your ceiling fans from being affected by the
1 key-for fan low speed.
YOUR REMOTE NOW HAS FULL CONTROL OF THE FAN AND LIGHT.
OFF key-for fan off.
LIGHT key-for light on and off.
2 key-for fan medium speed.
Operating the buttons on the panel of the transmitter.
3 key -for fan high speed.
2. OPERATING TRANSMITTER:
Do NOT install this fan with variable speed wall
WARNING:
2hr , 4hr , 8hr button to set the FAN sleep timer
remote control of the adjacent ceiling fans, first turn the switch in each remote control transmitter to the CODE(UP) position (see the
schematic diagram FIG1) Remarks: The standard state of the transmitter is in the down code COM.
(Power-off means you need to use a wall switch to shut down the power of the ceiling fan, if you do not have a wall switch,
please power off the whole room from the air circuit-breaker for each room)
After installing the remote control receiver on the ceiling fan
1: Turn on the power of the 1# ceiling fan receiver (the power of the 2# receiver is kept in a power-off state), within 30 seconds after
the fan power is turned on, press the LEARN button corresponding to the 1# transmitter, then The receiver will learn the transmitter code.
When the transmitter code is learned successfully, the light of the ceiling fans will flash twice, and then it can be used normally.
2: Turn on the power of the 2# ceiling fan receiver (the power of the 1# receiver is kept in a power-off state), within 30 seconds after
the fan power is turned on, press the LEARN button corresponding to the 2# transmitter, then The receiver will learn the transmitter code.
When the transmitter code is learned successfully, the light of the ceiling fans will flash twice, and then it can be used normally.
FCC Statement:
This device must accept any interference received, including interference that may cause undesired operation.
This device may not cause harmful interference.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may casue harmful interference to radio communications,
However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
--- Reorient or relocate the receiving antenna.
--- Increase the separation between the equipment and receiver.
--- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--- Consult the dealer or an experienced radio/ TV technician for help.
control or wall-mounted dimmer switch. It will
permanently damage the fan's remote control
and cause the fan's function to fail.
NO Variable speed wall control
NO Dimmer switch
TRANSMITTER
ACN
INPUT
ACL
RECEIVER
(FIG.1)
ANT
CODE
COM
CODE
LEARN
CODE
MODEL:GA043
OPERATION DISTANCE 20 FEET
CODE
CR2032
LEARN
CODE
LEARN
Open battery compartment
to remove insulation spacer
before use transmitter
PULL
REMOVE BEFORE USE
CR2032
OUTPUT

7
Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
6
6
7.67in
5.9in
6.3in
10.15in
7.08in
5.51in
52in
∅52in

Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
8
WARNING INGESTION HAZARD:
This product contains a button cell or coin battery.
Remove and immediately recycle or dispose of used batteries according to local regulations and keep away from children.
Do NOT dispose of batteries in household trash or incinerate. Even used batteries may cause severe injury or death.
Call a local poison control center for treatment information. Compatible battery type is CR2032, 3V.
Ensure the batteries are installed correctly with regard to polarity (+ and -).
Do not mix old and new batteries, different brands or types of batteries, such as alkaline, carbon-zinc, or rechargeable batteries.
Non-rechargeable batteries are not to be recharged. Exhausted batteries are to be removed from the product.
Do not force discharge, recharge, disassemble, heat above (manufacturer's specified temperature rating) or incinerate.
Doing so may result in injury due to venting, leakage or explosion resulting in chemical burns.
Remove and immediately recycle or dispose of batteries from equipment not used for an extended period of time according to local regulations.
Always completely secure the battery compartment. If the battery compartment does not close securely, stop using the product, remove the batteries,
and keep them away from children.
WARNING
INGESTION HAZARD:
This product contains a
button cell or coin battery.
DEATH
or serious injury can occur if ingested.
A swallowed button cell or coin battery can cause
Internal Chemical Burns
in as little as 2 hours.
KEEP
new and used batteries
OUT OF BEACH OF CHILDREN
Seek immediate medical attention
if a
battery is suspected to be swallowed or inserted
inside any part of the body.

9
Installation & Operating Instructions for the
Perimost Owner's Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
530173SQQSNDW
530173SQQSNBW
530173SQQWO
AFTER INSTALLATION
The fan blades have been adjusted in the factory to minimize any wobble
NOTE:CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY
ARE MOUNTED ON A RUBBER CROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE
CEILING, IT WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF A FEW CENTIMENTERS
IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM
WOBBLE”
TO REDUCE THE FAN WOBBLE: PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING
BRACKET AND DOWNROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN:
1.Check that all blade and blade arm screws are secure.
2.Mos
t fan wobbling problems are caused when blade levels are unequal. Check this level by
selecting a point on the ceiling above the tip of one of the
blades. Measure this distance.Rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. The distance deviation should be equal within
1/8"(0.32cm).
3.If the blade wobble is still noticeable, interchanging two
adjacent (side by side) blades can redistribute the weight
and possibly result in smoother operation. WARNING: TO REDUCE THE RISK OF PERSONAL
INJURY, DO NOT BEND THE BLADE ARM WHILE INSTALLING, BALANCING THE BLADES, OR
CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.
NOISE
When it is quiet(especially at night) you may hear occasional small noises. This is normal. Please allow a 24-
hour “breaking-in” period, most noises associated with a new fan disappear during the time.
CARE AND CLEANING
1.Periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to
avoid scratching the paint finish. Please make sure to turn off electricity power before you clean your fan
2.Do not use water when cleaning your ceiling fan. It could damage the motor or the blades
and create the possibility of an electrical shock.
3.Motor has permanently lubricated ball bearing. No need to oil
NOTE: MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU
ATTEMPT ANY CLEANING OR REPAIRS.