Senville SENWH-HP65US 65 Gallon Heat Pump Water Heater with 3.75 UEF, ENERGY STAR Certified

Product's Documents

Below are documents related to this product, you can read online or download:
SENWH-HP65US photo

Owner's Manual

This is the main product document for model SENWH-HP65US.

The file format is pdf, 40 pages, you can download this manual here .

background
Electric Residential Hybrid
Water Heater
With Installation Instructions for the Installer
USE & CARE MANUAL
Warning: DO NOT destroy or lose this manual. Please read the manual thoroughly. Store manual for easy retrieval
to change without advanced notice. Consult your manufacturer or your dealer for details concerning your
product. The diagram pictured on front cover is a reference image; please take the appearance of the actual
product as the standard.
as a future reference. As a result of product improvement, specification and design of this water heater are subject
SENWH-HP50US
SENWH-HP65US
background
2
2
INTENDED USE
CONTENTS
INTENDED USE
...............................................................................................................
SAFETY INSTRUCTIONS ........................................................................................................
SPECIFICATION SHEET ..........................................................................................................
INSTALLATION INSTRUCTIONS.........................................................................................
.........................................................................................
.........................................................................................
.........................................................................................
.........................................................................................
OPERATING INSTRUCTIONS
CARE & CLEANING
TROUBLESHOOTING TIPS
CUSTOMER SERVICE
3
2
8
22
24
3
This manual will provide the installer with recommendations and basic instructions for the proper
installation and adjustment of the water heater. This manual will explain to the owner-operator: the features,
operations, safety precautions, maintenance, and troubleshooting steps of the water heater.This manual
includes a replacement parts list.
The instructions must be read carefully by the owner-operator to ensure that they can adjust the water
heater or operate the water heater proficiently. Please seek professional advice if you find that you do not
understand the instructions.
For addition questions regarding service, warranty, and maintenance that are not covered by these
instructions, please contact the seller from whom your product was purchased.
9
19
2
background
3
3
SAFETY INSTRUCTIONS
For Your Records
Read This Manual
Write the model and serial numbers here:
# ___________________________________________________________________
# ___________________________________________________________________
Check rating label on the front of your water heater for these numbers.
Keep track of sales slip and proof of original purchase. This evidence is needed by owner to obtain service
under warranty.
Preventative care by owner can maximize the life of the water heater. Please refer to CARE & CLEANING
section and TROUBLESHOOTING TIPS section. This may prevent you from making a service call for your unit.
Explanation of symbols
DANGER
This represents a serious hazard that must be taken seriously to avoid death or injury to
yourself and others.
WARNING
CAUTION
This symbol indicates owner/user should take care to avoid minor or moderate injury in
a potentially harmful situation.
NOTICE
Read The Safety Information
Your safety is important. The safety of others is important. There are important safety messaged in this
manual and for your water heater. Obey all safety messages.
Located to the left is a symbol fort safety alert. That symbol indicates Important Safety
This represents a potentially hazardous situation. Warnings should be noted so that users
can avoid situations that could result in damage to property and/or death or serious injury.
This symbol is to indicate that attention should be directed towards a specified procedure
or maintain a specific condition.
Information regarding potential hazards that can cause harm or death to you and others.
Please see explanation of symbols below for “DANGER”, “WARNING”, “CAUTION” or “NOTICE”.
background
4
4
DANGER - WATER TEMPERATURE SETTING
DANGER
NOTICE
Temperature Time To Produce a Serious Burn
120°F (49°C) More than 5 minutes
125°F (52°C) 1
1/2
to 2 minutes
130°F (54°C) About 30 seconds
135°F (57°C) About 10 seconds
140°F (60°C) Less than 6 seconds
145°F (63°C) Less than 3 seconds
150°F (65°C) About 1
1/2
seconds
155°F (68°C) About 1 seconds
Table courtesy of Shriners Burn Institute
Time/Temperature Relationship in Scalds
DANGER
Important Safety Information - Read All Instructions Before Using
To use demand response for your water heater, use a thermostatic
mixing valve (that conforms to ASSE 1017) on the hot water supply
line following instructions.
This water heater can make water
hot enough to cause severe burns
instantly, resulting in severe injury
or death. Be careful to have
children, disabled and elderly not
exposed to scald risk.
Before setting temperature at
water heater, see instruction
manual. Test water temperature
before bathing or showering.
Refer to manual for temperature
limiting valves reference.
The guide above shows how fast it is possible to be
scalded based on the output temperature of the
water. Use this guide to determine the proper water
temperature for your home.
It is important to note that higher temperatures of
water increases scald risk.
If the SUPPLY CORD is damaged, it must be replaced by the
manufacturer,its service agent or similarly qualified person in order
to avoid a hazard.
Please consider safety and energy conservation when selecting
the water temperature setting of water heater.
Severe burns can occur from hot water.
In extreme cases, death from scalding can occur. As owner-operator,
be sure to read and follow the warnings outlined on the label
pictured right. This label is also located on the water heater.
Heat Pump Strictest operation environment: 3°C~43°C. Heating
element Strictest operation environment: -15°C~46°C. Strictest
operation environment:-15°C~46°C. Temperature can set range
is 43°C~65°C.
The vent shall not be obstructed.
It is possible to reduce point of use water temperature with a mixing
valve. The way that mixing valves work is that they mixing hot and
cold water in branch water lines. Please note that this product does
not include a mixing valve. During installation and use, it is necessary
to purchase and install a mixing valve separately.It is recommended
that a mixing valve complying with the Standard for Temperature
Actuated Mixing Valves for Hot Water Distribution Systems,
ASSE 1017 before being installed. See page 33 for more details.
For assistance, please contact a licensed plumber for further
information.
This applianceis not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance. Before the water heater
is shipped from the factory, it was set to a temperature
of 120 °F (49°C) to reduce the risk of scald injury
(For CAN – factory set to 140 °F (60.0°C)). This is done
to comply with safety regulations. Refer to illustration
below shows the water temperature setting. Refer to
the Operating instructions on Page 27 in this manual
for detailed instructions in how to adjust the water
temperature.
background
5
Relief Valve Warnings
Safety Devices
Pressure & Temperature Relief (PTR) Valve
Please note that this valve is located near the top
of the water heater and is essential for safe operation.
It is normal for the valve to release a small quantity
of water through the drain line during heating.
Temperature sensors, overheat sensors and switch-
es and a Pressure & Temperature Relief(PTR) valve
are supplied for the water heating system.
• DO NOT tamper with these device.
• DO NOT remove these devices.
DO NOT seal the PTR Valve or drain
pipe.
• DO NOT operate the system unless
each device is properly fitted.
5
The PTR valve or its drain must NEVER be blocked for any reason. Every 6 months the easing gear MUST be
operated in order to verify that they are not blocked and to remove lime deposits. Water heater may fail if
these steps are not followed.
Contact local plumber without delay if the PTR valve does (1) not discharge water when the easing gear
lever is opened, or (2) does not seal again when the easing gear is closed. The PTR valve is not serviceable
and must be replaced if damaged.
•
•
•
•
•
WARNING
DO NOT remove safety devices or tamper with them.
ENSURE that all safety devices are fitted and in working order BEFORE operating the water heater.
The PTR Valve and drain pipe MUST NOT be block or sealed in any way.
WARNING:
Contains coin battery.
BATTERY WARNING
INGESTION HAZARD: This product
contains a button cell or coin battery.
WARNING
BATTERY WARNING: KEEP OUT OF REACH OF CHILDREN;
If the battery compartment (if applicable) does not close
securely, stop using the product and keep it away from children.
If you think batteries might have been swallowed or placed
inside any part of the body, seek immediate medical attention.
WARNING
INGESTION HAZARD: This product contains a button cell or
coin battery.
DEATH or serious injury can occur if ingested.
A swallowed button cell or coin battery can cause Internal
Chemical Burns in as little as 2 hours.
KEEP new and used batteries OUT OF REACH of CHILDREN.
Seek immediate medical attention if a battery is suspected
to be swallowed or inserted inside any part of the body.
KEEP OUT OF REACH OF CHILDREN.
Swallowing can lead to chemical burns, perforation
of soft tissue, and death. Severe burns can occur
within 2 hours of ingestion. Seek medical attention
immediately.
BATTERY WARNING
WARNING
Remove and immediately recycle or dispose of used batteries according to local regulations and keep away
from children. Do not dispose of batteries in household trash or incinerate.
Even used batteries may cause severe injury or death.
Call a local poison control center for treatment information.
Non-rechargeable batteries are not to be recharged.
Do not force discharge, recharge, disassemble, heat above (-20-70℃) or incinerate. Doing so may result in
injury due to venting, leakage or explosion resulting in chemical burs.
Ensure the batteries are installed correctly according to polarity (+ and -).
Do not mix old and new batteries, different brands or types of batteries, such as alkaline, carbon-zinc, or
rechargeable batteries.
Remove and immediately recycle or dispose of batteries from equipment not used for an extended period of
time according to local regulations.
Always completely secure the battery compartment. If the battery compartment does not close securely,
stop using the product, remove the batteries, and keep them away from children.
Battery type: CR2032
Battery nominal voltage: 3.0 V
Lower lever carefully
until water flows from
drain line.
background
6
6
SAVE THESE INSTRUCTIONS.
NOTICE
WARNING
WARNING
Safety Precautions
Read And Follow This Safety Information Carefully
In order to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal
injury, or loss of life, please follow the information in this manual.Before attempting to install or operate
this water heater, be sure to read and understand the entire Use and Care Manual.
STOP if you have any issues understanding the instructions in this manual and get help from a local
plumber, local plumbing authority, local electric utility, or qualified service technician.
BEFORE starting maintenance, disconnect all power
to unit in order to avoid electrical shock resulting in
severe personal injury or death.
A water heater equipped with an adjustable tempera-
ture-regulating control shall be provided with instruc-
tions that: Inform the user that the thermostat , as
applicable, has been set at the factory to 120°F
(49°C) or lower, to reduce the risk of scald injury (For
CAN -factory set to 140°F(60.0°C).
COMPRESSOR IS NOT SERVICEABLE; DO NOT
ATTEMPT TO SERVICE COMPRESSOR.
The pressurized refrigerant and oil can escape if the
compressor wiring terminais arc. This can cause the
compressor to ignite and cause serious bodily injury,
severe burns or death.
• Know the location of the circuit breaker and how to shut it off if necessary. If you cannot
find the circuit breaker, ask the installer to locate it for you. Should the water heater be subjected
to overheating, fire, flood physical damage or if the ECO (temperature limiting control) fails to shut
off, turn off the circuit breaker IMMEDIATELY.
• Local codes and the provided installation instructions should be used to ensure your appliance is
properly installed.
• Servicing should be referred to a qualified technician. DO NOT repair or replace any part of your
water heater unless it is specifically recommended in this manual.
• DO NOT attempt to repair any part associated with the sealed refrigerant system.
• MAKE SURE the water heater is completely filled with water BEFORE turning on the electrical
supply.
CAUTION
In order to avoid a hazard due to inadvertent reset-
ting of the THERMAL CUT-OUT, this appliance must
not be supplied through an external switching device,
such as a timer, or connected to a circuit that is
regularly switched on and off by the utility.
WARNING
WARNING
WARNING
Pressure & Temperature Relief (PTR) Valve (Required) and Expansion Control Valve (ECV)-(If Required)
Excessive Discharge From Safety Devices
A small quantity of water will discharge from the PTR valve during normal operation during the heating cycle of
the water heater. Continuous and ongoing leakage of water from the valve and its drain line may indicate a
problem with the water heater.
If the valve leaks continuously but by not a large amount, then there may be foreign matter inside the valve.
Locate a bucket to place under valve and ease the valve gear for a few seconds to dislodge the debris.
HOWEVER, if the valve discharges at high flow this may be because the water pressure is exceeding the design
pressure of the water heater. Ask your installer or local plumber to heater. fit a Pressure Limiting Valve (PLV).
•
•
•
DO NOT EVER replace the PTR valve with one which
has a higher pressure rating than is specified for your
water heater; This can result in damage to the water
heater and create unsafe conditions.
background
7
Refrigerant
This Hybrid Water Heater is factory charged with R134a; do not attempt to service refrigerant.
When using electrical appliances, basic safety precautions to reduce the risk of fire, electric shock, or injury to
persons should be followed, including: READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.
This water heater must be grounded. Connect only to properly grounded outlet. See "GROUNDING
INSTRUCTIONS" page 18.
7
Operating Principle
System Schematic
The electric heat pump operation is a reverse of a refrigerator’s operation. The heat pump transfers heat from
the ambient outside air into the water. Electricity is only used to operate the system.
The heat pump system will be more efficient at heating water during warmer ambient conditions.
There is a micro-channel heat exchanger wrapped around the inner cylinder; this is to allow for thermal
conductivity between the refrigerant in the tank. A suitable tank temperature is achieved by using a
temperature sensor in the tank.
In the event that ambient weather conditions are not suitable for the heat pump to operate, the electric element
will provide heating to ensure operator-owner will have a supply of hot water.
EEV
DRY FILTER
EVAPORATOR
WATER TANK
HEAT EXCHANGER
MICRO-CHANNEL
* This figure only for reference,maybe differ from actual system
Install or locate this water heater only in accordance with the provided installation instructions.
Use this water heater only for its intended use as described in this manual.
As with any appliance, close supervision is necessary when used by children.
This water heater should be serviced only by qualified service personnel. Contact nearest authorized
service facility for examination, repair, or adjustment.
Do not use multi-outlet adaptors (i.e. power strips) with this water heater.
background
8
8
SPECIFICATION SHEET
This specification sheet is based on the ductless version of the appliance.
Inlet
Outlet
Sound
NEEA test protocol
Description
Energy Info
Features
Dimensions
Certifications
Element Wattage
Water Connection Size
UL 174
AHRI
NEEA
NSF/ANSI 372
Energy Star
Ship Length
Ship Height
Ship Weight
Drainage Hose
UL 60335-1 & UL 60335-2-40
Installation Clearnace (top)
Dry Fire Protection
Body Height
Body Diameter
Body Weight
Min. Circuit Amps
Electric Breaker Size
Replaceable Filter
Installation Clearnace (Back)
Installation Clearnace (side)
Built-in CTA-2045 Port
Leak Detection
8'' inlet&outlet air duct connection
Opration Modes
TP Valve installed
Recovery In G.P.H. 90℉ Rise
Heat pump ambient operating range
Heating element ambient operating range
LED Screen
WiFi-Ready
Uniform Energy Factor (UEF)
First Hour Rating (FHR)
Compressor capacity
Total Unit Wattage (input)
Cold Climate Efficiency(CCE)
Model Number
Normal Gallon Capacity
Rated Gallon Capacity
Voltage
Water Outlet Temperature Range
Upper
Lower
80
75
4.00
91
74 3/5 inch
25 7/10 inch
293.22 lb
30 3/10 inch × 29 1/10 inch
83 2/5 inch
357.15 lb
208V/240V, 60Hz, 1Ph
4500W(240V)
4500W(240V)
1500W
5500W
3
27.5
Optional
Optional
5
23.6A(208V)/26.8A(240V)
25A(208V)/30A(240V)
0''
6''
20''
3/4inch
3/4inch
3/4inch
Tier 4
49.5dB(A)
x
√
√
√
√
√
√
√
√
√
√
37
℉
~109
℉
(
3
℃
~43
℃)
109
℉
~149
℉(
43
℃
~65
℃)
5
℉
~115
℉(
-15
℃
~46
℃)
50
47
3.75
69
66 4/5 inch
218.26 lb
28 7/10 inch × 27 3/5 inch
75 1/5 inch
264.56 lb
21 9/10 inch
65
61
3.90
80
65 6/7 inch
271.39 lb
30 1/10 inch× 28 9/10 inch
75 3/5 inch
334 2/9 lb
25 7/10 inch
SENWH-HP80
SENWH-HP50 SENWH-HP65
background
9
10
INSTALLATION INSTRUCTIONS
Local Installation Regulations
Inspect Shipment
The location chosen for the water heater must take into consideration the following:
Location
Locate a clean dry area for your water heater
and position it as near as practical to the area of
greatest heated water demand. Please understand
that long un-insulated hot water lines can waste
energy and water.
Ensure that the thermistor and element access
panels can be removed when choosing a location
for the water heater. This is to permit inspection
and servicing such as removal of elements or
checking controls.
Protect the water heater and water lines from
freezing temperatures, AVOID installing the water
heater in outdoor, unprotected areas.
The floor underneath the water heater MUST be
strong enough to support the weight of the water
heater after being completely filled with water.
Where applicable, install a floor isolation kit is
recommended to minimize vibrations.
The Water Heater should not be located in an
area where leakage of the tank or connections
will result in damage to the area adjacent to it
or to lower floors of the structure. Where such
areas cannot be avoided, it is recommended
that a suitable drain pan, adequately drained,
be installed under the water heater.
CAUTION
If adequate ventilation is not provided for installs
inside confined spaces, the unit will have higher power
consumption.
DO NOT install the hybrid water where ambient
temperaturesEXCEED 114°F(46°C)
NOTICE
NOTICE
Diameter of water
heater plus 4” min.
A
A
Maximum 2”
To open drain, line
should be at least
3/4” ID and pitched
for proper drainage.
B
Clearances
Rear Sides Top
0” 6” 20”
B
Follow the instructions in this manual, local codes, utility codes, utility company requirements or, in the
absence of local codes, the latest edition of the National Electrical Code while installing this water heater.
These materiais are available from some local libraries. These materiais also be purchased from the National
Fire Protection Association. Batterymarch Park, Quincy, MA 02269 as booklet ANSI/NFPA 70.For Canadian
owners, please refer to Canadian Standards Association, 5050 Spectrum Way, Missisauga, ONT L4W 5N6 to
purchase standard CSA22.1.
Installation should be avoided in an environment where flammable and explosive gases are leaking or where
there are strong corrosive gases.
ENSURE that the auxiliary drain pan conforms to local codes.
Purchase drain pan kits from the store where the water
heater was purchased, or any water heater distributor.
ENSURE that the drain pan DOES NOT obstruct cold inlet
or drain valve.
Check the water heater for possible shipping damage after receiving the unit. Be certain that the power supply
corresponds to the water heater requirements by checking the marking on the rating plate. Rating plate is located on
front of water heater.
background
10
11
Min 6”
The clearance requirements of this water heater as follows:
Minimum Required Clearances
This installation clearance is required for both 50 and 80 gallon heaters
Back Left Side Right Side
Top
0 0 6'' 20''
Front
Min 20”
background
11
12
Duct Adapter Kit Installation
NOTICE
50
NOMINAL
GALLON
CAPACITY
DIMENSIONS(SHOWN IN INCHES)
65 80
71
7
/
8
70
5
/
8
79
6
/
8
46
4
/
8
97
4
/
8
30
6
/
8
30
6
/
8
25
6
/
8
37
6
/
8
88
3
/
8
25
5
/
8
26
7
/
8
21
6
/
8
5
4
/
8
5
4
/
8
5
4
/
8
39
4
/
8
≥59
1
/
8
≥59
1
/
8
≥59
1
/
8
89
5
/
8
A
B
C
D
E
F
G
HPWHA-08A(UL)
1. Duct Adapter A
2. Duct Adapter B
3. Sealplate
1. Duct Adapter A 2. Duct Adapter B 3. Sealplate
15”
5
”
1
/
10
11
”
4
/
5
10
”
4
/
5
2
”
1
/
10
1
”
7
/
10
8
”
7
/
10
14
”
1
/
5
9
”
3
/
5
1. Glue sponge along the edges
of the duct adapter and
sealplate.
2. Secure the duct adapter
Cover to the tank,then fix the
screws.
3. Secure the sealplate Cover to
the edge of duct adapter .
Sponge
Sponge
Sponge
Duct Adapter B
Screw
Sealplate
Duct Adapter A
Duct Adapter B
Screw
Duct Adapter A
1 2 3
Must be installed by professionals. It is recommended to adjust
the engineering channel 40(Detail operation please look at the
part of “OPERATING INSTRUCTIONS→Setting Menu ”in the
USE&CARE MANUAL) after installing the air duct to achieve
better performance.When installing the ducting , obstacles need
to be kept at a certain distance from the duct adapter, as shown
in “F” (Fig1); the headroom required for installation is shown in
“G”(Fig1).Objects around the duct need to be more than 1 inch
away from the duct.
Duct Adapter Kit
Fig1
8”
Insulated
Flex Duct
(Flex Duct Insulation
extended over reducers
and secured with Duct tie)
Wall
Air Inlet
HVAC tap
used to seal
Reducer and
Termination
Joints
Cold Air
Exhaust
Adjustable
Elbow
secured with screws
to unit adapter
duct adapter A
duct adapter B
A
B
C
E
D
F
G
(SENWH-HP50.3-2)
(SENWH-HP50.3-3)
(SENWH-HP50.3-4)
background
12
13
Ducting Requirements
Duct System Configuration
Accessory Installation Requirements (not included)
Elbows/Bends
Terminations/Registers
Duct Type / Diameter 8” 7” 6” 5”
Rigid 357’ 168’ 68’ 18’
Flexible 131’ 68’ 26’ --
Table 1 - Maximum Duct Length
Considerations when planning the duct system:
Use direct route for running the ducting.For best
airflow, reduce elbows/bends used in layout as
much as possible.
Uilize largest duct size for project that is
allowable for install.
Damper
Before designing the duct system, always check
with local building and HVAC codes. Read
these instructions carefully for ducting unit to
outdoors or other spaces. Any ducting
configurations that do not comply with these
instructions are not supported.
This water heater MUST be ducted separately from
other appliances. Only use ducting approved for
HVAC applications. ENSURE ducting is adequately
supported and that terminations are used.
HVAC approved indoor registers are required.
To minimize transmission of vibration or noise,
rigid ducting must be isolated from floor joists or
other structural members. Utilize a short section
(12 in. or larger) of flexible duct between the water
heater and rigid ducting as an isolation method.
Every foot of flexible ducting counts as three feet
of rigid ducting. Ducting must be insulated per
HVAC codes (to prevent condensation).
Cold air MUST exhaust is suciently away from
structures to prevent condensation on surfaces.
Lowering resistance to airflow and regular filter
maintenance will maximize heater performance.
Providing unit with warm moist air is also
beneficial to the performance of the water heater.
•
•
•
Use 8 in. diameter ducting for inlet and outlet ducting connections on the water heater.
Note that 7 inch, 6 inch, 5 inch diameter ducting are supported. Total feet of ducting allowed is in Table 1.
An elbow is defined as a rigid duct with a flex
bends greater than 45°.
If a bend is needed that has a tighter radius then
its diameter, then a rigid elbow must be used.
Smaller diameter terminations and registers with
more than a 2 ft. connection should not be used.
The angle of the duct adapter needs to be main-
tained at an inclined angle to avoid
rainfall backflow.
An approved damper should be installed no
further than 10 ft. of rigid ducting total (two
elbows equivalent)from the unit if ducting to
the outside while using an exhaust duct only
(no intake duct). This action will prevent outside
air from entering the living space.
All ducting accessories and installation need to
follow local electrical installation and building
code.When the installation is completed, the
equivalent pressure load needs to be less than 45
Pa or the airflow at the outlet of the water heater
needs to be no less than 150 m
3
/h. If the static
pressure is higher than 45Pa or the airflow at the
outlet is less than 150m3/h, the eciency will
reduce more than 20%.
When the unit is running in a high humidity
environment, it is recommended to add sponge
wrapping at the air outlet duct to reduce the
generation of condensation water.
NOTICE
These accessories will increase the load static pressure throughout the piping system and will
reduce airflow.
NOTICE
Utilize largest termination possible for ductwork
The length of duct is the length on the inlet plus
the length on the outlet. You may use any
combination of duct lengths to reach max.
duct length in Table 1.
background
13
14
Transport and Handling
Positioning The Heat Pump
Install a plinth under the heat pump
where it is subjected to wet conditions
• DO NOT drain on to grass or garden beds.
• DO NOT commence a job where the risks cannot be controlled.
NOTE
• Allow 200m
3
of free space surrounding the unit. This provides clear
ambient air flow assisting the product’s performance. Ensure the
clearance requirements specified in the section ‘Location’ on page
8 are complied with. The area MUST also be clear of debris such as
leaves and tree branches.
An open water system occurs if a cold water inlet line does not have a check valve or back flow prevention
device. This can cause a problem when thermal expansion occurs. Thermal expansion is the increase in
pressure and volume that water undergoes when it is heated. In an open water system, this thermal
expansion of the water exceeds the capacity of the water heater and then flows back into the city main
where the pressure is easily dissipated.
In contrast, a closed water system, prevents the expanding water from flowing back into the main supply
line. This can create a rapid and dangerous pressure increase in the water heater and system piping, which
will activate the safety setting of the relief valve. When the relief valve is constantly activated, it will cause
premature failure. Please note that replacing the relief valve WILL NOT resolve the problem.
To control thermal expansion, please install an expansion tank in the cold water line between the water
heater and the check valve. The expansion tank relieving the over pressure condition and prevents the relief
valve from being activated regularly. The expansion tank is built to have an air cushion built in that
compresses as the system pressure increases.
If you require more information on this subject, please contact your installing contractor, water supplier
or plumbing inspector. It is important to extend your water heater's longevity by using an expansion tank.
Thermal Expansion
Perform a Work Method Statements (WMS) or Job Site Analysis
(JSA) on site to ensure safety. Be careful to unload all materiais
in a safe manner.
For ease of unloading, position vehicle with all materiais and the
unit in a position near the work area.
Installer MUST consider impact to living areas caused by noise
of the water heater Avoid positioning unit against wall shared
with neighbours' bedrooms. The water heater is expected to run
at night and noise caused by the unit (while low) can be
considered interruptive to inhabitance of the home.
MAINTAIN access to the relief valve and anodes.
OBSERVE all plumbing and building regulations while installing
unit. ENSURE the unit is installed on a flat and level surface.
To prevent property damage from water spillage, you MUST
use a properly drained overflow tray (See AS/NZS 3500.4.2 for
further details.)
DO NOT drain into gardens or outdoor areas containing greenery.
DO NOT start the job of installing the water heater when risks
cannot be controlled.
ENSURE 200m of free space to provide
clear ambient airflow around the water heater; this helps the water
heater's performance. This free space must be clear of debris,
stored items, tree branches, and obstructive elements.
2
•
•
•
•
•
•
•
•
•
background
14
15
NOTICE
NOTICE
Consult local codes or ordinances fo specific requirements. Refer to page 16.
IMPORTANT: When making drain fitting connections to the drain tubing, use a clamps secure.
IMPORTANT: When making drain fitting connections to the drain tubing, DO NOT overtighten. Overtightening
fittings can split pipe connections on the drain pan.
Water Supply Connections
Condensate Drains
Refer to the illustration on Page 19 for water supply connections.
The HOT and COLD water connections use 3/4" NPT on all models. Please install a shut- off valve in the cold
water line near the water heater.These appliances are intended to be permanently connected to the water mains,
and shall not connected by hose-sets.See page 16 for further instruction on "To Fill The Water Heater".
Water inlet or outlet pipes: The spec of the water inlet or outlet thread is 3/4" NPT (external thread). Pipes
must be heat-resistant and durable. The outlet of drain pan should be connected to the drainage system by
DETACHABLE HOSE -SETS the new hose-sets supplied with the appliance are to be used and that old
hose-sets should not be reused.
Installation of the pipe for PTR valve: The valve connecting thread is 3/4" NPT (internal thread). After
installation, it must be confirmed that the drainpipe outlet is exposed in the air All piping properly installed
and free of leaks. Unit completely filled with water. Tempering valve installed per manufacturer’s instructions
The water in this appliance does not need to be potable,if a potable water source is used for the equipment’s
water supply, the source water supply shall be protected against back siphonage by the equipment. Besides,
The water inlet or outlet of the equipment is unpotable A one-way valve must be installed on the water inlet
side, as well as an isolation value. It is normal for some water to be released from the PTR valve during
operation. But, if there is a large volume of water, call your service agent for instructions. After long term use,
check the unit base and fittings.
If damaged, the unit may sink, resulting in injury. Arrange the drain pipe to ensure smooth draining. Improper
drainage work may cause wetting of the building, furniture etc. Do not touch the inner parts of the controller
or remove the front panel. Some parts inside are dangerous to touch, and damage may be caused.
DO NOT apply heat or heating processed to the HOT or COLD water connections during installation; doing
so will damage the heat traps. Connect the hose to the adapter before installing the adapter to the water
connection on the heater.
For more requirements, please consult local codes or ordinances. Refer to page 10.
IMPORTANT: USE SECURE CLAMPS when making drain fitting connections to the drain tubing.
IMPORTANT: DO NOT over-tighten when making drain fitting connections to the drain tubing. Overtightening
fittings can split pipe connections on the drain pan.
DO NOT reduce drain line size less than connection size provided for the condensate drain.
To ensure proper drainage, pitched drain lines downward away from the unit a minimum of 1/8" per foot of
line include a P-trap in drain line if itis connected to a sewer pipe.
DO NOT allow water heater drain pan to be used as a condensate drain.
INSULATE the drain line to prevent sweating an damage due to condensate forming on the outside surface
of the line.
•
•
•
•
•
•
•
Condensate is not required to be neutralized from this unit because it is not acidic.
background
15
20 Minimum clearance above heat
pump to allow for filter maintenance
16
Typical Installation
T&P plumbing MUST go directly to a suitable
open drain.
T&P MUST NOT connect to the condensate
plumbing.
Ceiling
Air filter
Disassemble position
A temperature and pressure relief valve (that complies with the Standard for Relief Valves for Hot Water
Supply Systems, ANSI Z21.22) is factory installed and must remain installed.
DO NOT install a valve of any type between the relief valve and the tank.
Relief Valve (T&P Valve)
Look at the rating label of the water heater, the btu/h rating of the relief valve must not be less than the
input rating listed (1 watt = 3.412 btu/h).
DO NOT allow discharge water to contact live electrical parts. Make sure that the relief valve is connected
to a suitable open drain.
ONLY use piping that is approved for hot water distribution. The outlet of the valve and must pitch
downward from the valve. This allows complete drainage (by gravity) of the relief valve and discharge line.
The discharge line should be protected from freezing.
DO NOT install a valve of any type, restriction or reducer coupling in the discharge line.
The pressure rating of the relief valve must
NOT exceed the maximum working pressure
of the water heater as marked on the rating
place (150 PSI).
CAUTION
To reduce the risk of excessive pressures and temperatures in this water heater, install temperature and
pressure protective equipment required by local codes and no less than a combination temperature and
pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic
inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves
and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22. This valve must be marked
with a maximum set pressure not to exceed the marked maximum working pressure of the water heater.
Install the valve into an opening provided and marked for this purpose in the water heater, and orient it or
provide tubing so that any discharge from the valve exits only within 6 inches above, or at any distance below,
the structural floor, and does not contact any live electrical part. The discharge opening must not be blocked
or reduced in size under any circumstances.
WARNING
WARNING
background
16
17
To Fill the Water Heater
Electrical Connections
Right Side View
Junction
Box Cover
Conduit
Connector
Ground
Screw
Wire
Connections
CTA Adaptor
(Not applicable
for all models)
Water Heater Junction Box
Ensure the closure of the drain valve before
starting this process. For the cold water
supply line, open completely.
Allow the air to vent from the water heater
and piping by opening each hot water faucet
slowly to allow. A steady flow of water from
the hot water faucet(s) indicates a full water
heater.
Built-in leak detection and automatic water
shut off valve protect the water heater. The
app is notified if there is a trigger for leak
detection and the unit will shut down.
The manufacturer's warranty will be void if
installer or owner fails to follow the instructions
provided in this manual. Failure to follow directions
in manual may permanently damage the unit.
ENSURE the water heater is completely filled with
water before turning on the electrical supply.
If the water heater is operated with an empty or
partially empty tank, the warranty does not cover
the resulting damage or failure.
Before making any electrical connections, turn off
electric power at the fuse box or service panel.
ENSURE ground connection is completed before
making line voltage connections. Death,injury, or
electrical shock can result in failure to do so. Also,
before any maintenance, disconnect all power to
unit before starting maintenance.
DO NOT operate the water heater if the water
heater has been subjected to fire, flood or physical
damage, until it has been checked by a qualified
service technician.
NOTICE
If this water heater or any part of this water heater has been under water and/or flooded, DO NOT attempt
to repair the unit! It must be replaced.
A qualified electrician be commissioned to provide a
separate branch circuit with copper conductors, over
current protective device and suitable disconnecting,
Latest edition of National Electrical Code ANSI/NFPA
70 and ali local codes must be conformed to for wiring.
WARNING
WARNING
WARNING
Green/Y&G)
Ground Wire
Connection
L1 L2
Grounding
Screw
L1 Wire
Connection
L2 Wire
Connection
Junction Box Details
background
17
Grounding Instruction
Air Outlet
Opening
Controller
Assembly
Vertical
Flexible Filter
Branch Circuit Sizing And Wire Size
Guide - Single Phase Wiring
CAUTION
If local codes require the application of an external
insulation blanket to this water heater, pay careful
attention to the following so as not to restrict the
proper function and operation of the water heater:
CAUTION
NOTICE
Recommended Over
Current Protection
(Fuse or Circuit Breaker
Amperage Rating)
Copper Wire Size
AWG Based on
NE.C Table 310-16
(75°C)
5500
Insulation Blankets
18
MAKE SURE unit is full of water before turning on the
electrical supply or operating this water heater.
Refer to National Electric Code. Refer to wiring
diagrams in this manual for field wiring connections.
Note that the presence of water in the piping and
water heater does not provide acceptable conduction
for a ground. The water heater can become electrically
isolated if non-metallic piping, dielectric unions,
flexible connectors etc. are used.
NOTE: When sizing the breaker and wire for over
current protection, include an additional 500W to the
upper element wattage rating for the maximum
amperage draw of the compressor and fan motor.
Follow the manufacturer's instructions on insulation
blanket kits included with the kit carefully if local codes
require external application of insulation blanket. An
insulation blanket can reduce standby heat loss.
This manufacture's warranty does not claim
responsibility for any damage or defect caused by
installation, attachment or use of any type of energy
saving or other unapproved devices (other than those
authorized by the manufacturer) into, onto or in
conjunction with the water heater.
Operating or warning labels attached to the
water heater MUST STAY visible.
Air openings on both sides of the water heater
MUST STAY OPEN.
Controller Assembly, temperature and pressure
relief valve or drain valve SHOULD NOT be
covered.
Frequently inspect the insulation blanket.
•
•
•
•
L1
L2
GND
Power Cable
Circuit Breaker
(including GFCI type)
Power Supply
1. Metallic conduit or metallic sheathed cable
(approved for use as a grounding conductor).
These must be installed with fittings approved for
the purpose.
2. A separate conductor for grounding shall be �
included for non-metallic sheathed cable, metallic
conduit or metallic sheathed cable not approved
for use as a ground conductor.
3. The unit in must be installed with a circuit breaker
(including GFCI type) near the power supply and
must be effectively earthed.
4. All wires connection refer to page 39.
Maximum
Wattage
30 10
240V 240V
25
208V
WARNING
WARNING
background
18
Hot and Cold Pipe Insulation Installation
Install the insulation on the cold water supply inlet and the hot water outlet as shown in the illustration.
Relief
Valve
Hot Water
Outlet
Shut off Valve
(Not included in all models)
Drain Valve
Leak Sensor
(Not included in all models)
Cold Water
inlet
19
background
19
Operating The Water Heater
OPERATING INSTRUCTIONS
CAUTION
The cause of the high temperature condition must be investigated by qualified service technician and
corrective action must be taken before placing the water heater in service again.
Safety Precautions
Safety Controls
The water heater is equipped with a temperature limiting control (ECO) that is located above the upper
heating element in contact with the tank surface. If for any reason the water temperature becomes
excessively high, the temperature limitig control (ECO) breaks the power circuit to the heating element. Once
the control opens, it must be reset manually.
DO NOT use this appliance if any part has been under water. Immediately call a qualified installer or service
agency to replace a flooded water heater.
DO NOT attempt to repair the unit! It must be replaced.
NOTICE
To reset the temperature limiting control (Refer to illustration in Cavity Insert section):
1. Disconnect all power to unit before starting maintenance.
2. Remove the upper cavity cover and insulation.
3. Press the red RESET button.
4. Replace the insulation, jacket access panel and plastic housing before turning on the power to the
water heater.
20
Hydrogen gas (EXTREAMLY FLAMMABLE) can be produced in a hot water system served by this water heater
that has not been used for a period of two weeks or more. It is recommended that the hot water faucet be
opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water
system.
You will hear a strange sound of air escaping if hydrogen is present. Do not have open flame or smoke near any
facet if this is the case.
1. If water heater if it has been subjected to over heating, fire, flood, or physical damage,disconnect the power.
2. Fill water heater completely before turning water heater.
3. If cold water supply shut-off valve is closed, DO NOT turn on water heater.
4. Itis recommended that a qualified person or serviceman perform the work.
If the water heater has been subjected to fire, flood or physical damage, disconnect all power to water heater.
DO NOT operate the water heater again until it has been checked by a qualified service technician.
Resetting ECO
WARNING
background
20
21
The temperature of the water in the water heater can be regulated by selecting the desired temperature
on control display. Safety and energy conservation are factors to be considered when selecting the water
temperature setting of the water heater. The lower the temperature setting, the greater the savings in
energy and operating costs.
To comply with safety regulations the temperature is factory set at 120°F (49°C) (For CAN -factory set to
140°F(60.0°C) or less where local codes require. This is the recommended starting point. Severe burns can
occur from hot water.
Be sure to read and follow the warnings outlined in this manual and on the label on the water heater.
This label is located on the front of the water heater.
Mixing valves are recommended for reducing point of use water temperature by mixing hot and cold water
in branch water lines. It is recommended that a mixing valve complying with the Standard for Temperature
Actuated Mixing Valves for Hot Water Distribution Systems, ASSE 1017 be installed. See page 4 for more details
and contact a licensed plumber or the local plumbing authority for further information.
When used in demand response applications a thermostatic mixing valve conforming to ASSE 1017 shall be
installed on the hot water supply line following all manufacturer installation instructions. See page 35 for
additional installation information.
The chart on the page 4 may be used as a guide in determining the proper water temperature for your home.
There is a hot water scald potential if the thermostat is set too high. Households with small children,
disabled, or elderly persons may require a 120°F (49°C) or lower thermostat setting to prevent contact
with HOT water.
DANGER
Operating The Water Heater (cont.)
Water Temperature Setting
background
21
22
Change Mode of Operation
Setting Menu
Press the “MODE” button to select operating mode.
Operation Modes
• Vacation
• Hybrid
• E-Heater
• Economy
• Heat-Pump
Mode Efficiency Recovery
Local Startup (cont.)
Enter the engineering channel mode:
Long press and hold the check button for 3 seconds on the
main interface.
0-Centigrade
1-Fahrenheit degree
Temperature unit
switching
Select engineering channel, press the confirm button to enter,
and switch between valid values using the up/down keys.
Engineering channel
Engineering channel 1
0:
O
ff
1:
O
n
Maintenance
reminder on
Engineering channel 2
Default value:
365 days
Maintenance
time setting
Engineering channel 3
0:Do not clear;
1:Clean up
Zero maintenance
time
Engineering channel 4
Hybrid mode
automatically
switches to
Economy mode
Engineering channel 20
0: No
1:Yes
0: No
1:Yes
E-Heater mode
automatically
switches to
Economy mode
Engineering channel 19
0:
O
ff(Backlight always on)
1:
O
n(Normal mode)
Backlight
Engineering channel 30
Heat-Pump
Vacation
Hybrid
E-Heater
Economy
Very High
N/A
Low
Very Low
High
Very Low
N/A
High
Very High
Low
Turn off sound
Engineering channel 34
Automatic child
lock
Engineering channel 35
Ball Valve
Engineering channel 38
Forced sterilization
Engineering channel 39
Air duct
Engineering channel 40
0:Off (Normal mode)
1:On(No buzzer sounds)
0:
O
ff (Normal mode)
1:
O
n
0:Null
1:With
0:
O
ff
1:
O
n(Valid once)
0:Null
1: With
2:Not recommended
to set
background
22
CARE & CLEANING
Draining the Water Heater
Routine Preventative Maintenance
DANGER
CAUTION
Vertical
Flexible
Filter
Filter
Handle
23
Be sure to shut-off power to the water heater before attempting to drain
the water heater.
Before manually operating the relief valve make certain no one will be
exposed to the hot water released by the valve to avoid any scald risk,
injury or damage.
Do not use volatile oils, alcohols, thinners, lacquers, etc. to clean the
machine; otherwise, the product may be damaged.
Turn off the cold water supply before drain the water heater.
Attach a garden hose to the drain valve on the water heater, open
the T&P valve, and direct the stream of water to a drain. Open the valve.
Your water heater will provide years of dependable trouble free service if you maintain your water heater
properly. However, contact a qualified installer or plumbing contractor to inspect unit if you see or hear any
strange behavior.
Annually you must:
1. Lift and release the lever handle on the temperature pressure relief valve and allow water to discharge
from the system.
2. Clean the air filter (or more often as needed). A clean filter is important for keeping air flow to heat
pump from being obstructed.
3. Pour bleach down the condensate drain.
4. Check that the condensate can flow freely.
5. Drain water heater to clear debris accumulated in tank from hard water deposits.
background
23
Vacation and Extended Shut-Down
Anode Rod
Refer to the Hydrogen Gas Caution in the Operating Instructions.
NOTICE
NOTICE
The power and water to the appliance should be turned off to conserve energy and prevent a build-up
of dangerous hydrogen gas for periods of inactivity longer then 2 weeks.
If there is risk that the water heater and piping will be subject to freezing while the init is inactive, the
water heater and piping should be drained.
The water heater's operation and controls should be checked by qualified service person after a long
shut-down period. Make sure to completely refill the water heater before placing it in operation.
The life of the glass-lined tank can be prolonged by the anode rod as it prevents corrosion of the tank.
Do not remove the anode rod.
The gas-lined tank of this water heater is protected by an anode rod. The purpose of this rod is to attract
corrosive elements inside of hard water so that the anode rod is sacrificed to corrosion instead of the insicle
of the water heater. For cases where the water contains high mineral content or high sulfates, this process
of the anode rod reacting to the water can cause an odor, This odor is similar to rotten eggs. This can happen
especially during long periods of inactivity. In this case, the owner can use the chlorine bleach removal method
by adding an automatic chlorination to the water system. The chlorine will eliminate the rotten egg smell
because it chemically reacts with hydrogen sulfice and disinfect the water.
24
background
24
1. When the self-protection happens, the system will
be stopped and start self-check, and restart when the
protection resolved.
2.When the self-protection happens, the buzzer will
buzz in all the time , the “ ” light up and error
code will be shown at water temperature indicator.
The “ ” and error code does not disappear until
protection resolved.
3. In the following circumstance, self-protection may
happen;
-Air inlet or outlet is blocked;
- The evaporator is covered with too much dust;
- Incorrect power supply (exceedingthe range of 187-265V).
1. If some normal errors happen, please contact
qualified staff to repair.
2. If some sever error happen, unit will not start,
please contact qualified staff to repair.
3. If a fault occurs, the “ ” icon will light up, the
buzzer will beep and the main interface will display
a fault code.
TROUBLESHOOTING TIPS
Troubleshooting
Before You Call For Service...
1 Non-error tips
Save time and money! Review the chart on this page first and you may not need to call for service.
2 Self-protection of unit
3 Recognizing an Error
Q: Why wont the compressor start immediately
after turning on the unit?
A:The pressure of system needs to be balanced.
This a self protection logic of unit that should
take 3-4 min.
Q:Sometimes the temperature shown on the
display panel decreases while unit is running,
why is this?
A:The upper tank temp and bottom tank
temp will mix when there is a temperature
difference, thus lowering the reading. This is not
abnormal operation.
Q: The display shows decreased temperature
unit but the unit is closed?
A: To avoid cutting on and off repeatedly, the
mechine will turn on only when T5U temperature
is lower than setting temperature for at least
5℃(50 Gal)/4℃(80 Gal).
Q:Why sometimes the temperature shown on the
display decreased but I still have hot water?
A: The upper water sensor is positioned on the
upper 1/4 of the water heater and therefore there
is still about1/4 of the tank of hot water avaiable
to the user.
Q: Why is it that sometimes the buttons are
unavailable?
A:Maybe the panel is locked, press
the “ ” and “ ” for 2 seconds, unit will lock
the panel,shows “ ” , to unlock the panel,
please press the “ ” and “ ” for 2 seconds again.
Q: Sometimes there is some water that flowed
from drainage pipe of PT valve, why does this occur?
A: Because the tank is pressure-bearable one, when
water is heated inside the tank, water will expand,
so the pressure inside of tank will increase, if pressure
goes up more than 1.0MPa,PT valve will activate to
relief the pressure and hot water drop will be
discharged correspondingly. If water drop is
continually discharged from PT valve drainage
pipe, it is abnormal, please contact qualified stuff
to check.
25
background
25
Troubleshooting (cont.)
4 Error phenomenon shooting
26
Error
phenomenon
Possible reason
solution
Cold water
tapped out and
display screen
extinguished
No hot water
tapped out
Water leakage
Hydraulic pipeline
joints are not sealed
well.
1. Plug in;
2. Setting water temp.
higher;
3. Contact service
center.
1.
Bad connection between
power supply plug and
socket;
2.
Setting water
temperature too low;
3.
Temp. sensor broken;
PCB of indicator broken.
Check and reseal all
joints.
1. Waiting for public
water supply recover;
2.Waiting for inlet water
pressure increase;
3.Open water inlet valve.
1. Public water supply
ceased;
2.Cold water inlet
pressure too low
(<0.15 MPa);
3.Cold water inlet
valve closed.
background
26
Press “ ” the button to select VACATION,
unit will automatically heat water to 15°C(59°F)
for the purpose of energy saving during
vacation days.
1 Basic function
1. Vacation function
2. How is the unit running
If unit is OFF -
>
press “
” -
>
unit will be
waken -
>
press “
” to set target water
-
>
“ ” unit will automatically select heat source
and start to heat water to target temperature.
3. Remote shutdown function
Users can connect a switch. If the switch
is closed, the unit will be stopped forcibly.
If switch breaks, the unit can run normally
according settings.
2 Query function
Press the ” “ button then system running
parameters will be shown one by one with
following sequence by each pushing of “
”
or “
” button.
27
No.
Hour
low bit
Min.
high bit
Min.
Low bit
unit
Explenation
1
Temp.
T5U
2
Temp.
T5L
3
Temp.
T3
4
Temp.
T4
5
Temp.
TP
6
Temp.
Th
7
8
9
10
11
12
Temp.
Temp.
Current
Temp.
Heat pump stop temp
Disinfect temp.
Compressor and
electric heating current
No.
Hour
low bit
Min.
high bit
Min.
Low bit
unit
Explenation
13
14
15
16
17
18
19
20
21
Fan
Ac Fan
0:OFF
1:LOW
2:MID
3:HIGH
22
23
24
25
26
27
28
Dc Fan
Real speed/10
Machine
parameters
0~255
Compression mechanism
hot water demand
0:Ac Fan
1:Dc Fan
1
(Eheater control type)
0
(Compressor control type)
Tank capacity
Four-way valve status
0
Host software version
LCD panel software version
000
Version
Version
Version
Electronic expansion
valve opening
29
30
31
32
33
34
35
36
0:One electric heater
2
Last error code
Previous 1 st error or protection code
Previous 2 nd error or protection code
Maintenance time
Target Temp
End sign
1:Two electric heaters
>
temperature (43°C/109°F~65°C/149°F) - press
background
27
28
1 Operation
1.1 Control Panel Explanation
1.2 Display Explanation
Display
Operation
N0 Icon Description
will be lightened if screen is unlocked.
It shows water temperature on normal;
It shows remaining vacation days on vacation;
It shows setting temperature on setting;
It shows unit setting/running parameters,
error/protection code on querying.
Time and clock setting
Whenever there is any setting for clock, SET TIME
will be lightened.
shows the clock.
1
2
3
4
There are daily or weekly TIMER icon.
If there is none of timers has been set, it will keep
extinguished.
If anyone of them has been set, this icon will lighten
the corresponding one when screen is unlocked
If timer is being set, this icon will flash the
corresponding one with 2Hz frequency as well
lighten the timer which has been set.
It flashes to remind the user to maintain the water tank
and clean the air filter. If you do not need maintenance
reminders, you can enter engineering mode channel 2
to disable this function, or engineering mode channel 4
to reset the maintenance reminder time, the default
maintenance reminder time is 365 days.
5
Lock:
If button is locked, the icon will be lightened, otherwise
it will be extinguished.
6
7
8
HYBRID MODE:
E-heat:
It will be lightened when E-heat is running, otherwise
it will be extinguished.
NOTE: When the operating conditions are not met to
turn on this function, the corresponding icon on the wire
controller lights up briefly and then goes out.
9
10
High temp. Alarm
If water temp is higher than
122 °F
(50°C), it will be
lightened,otherwise it will be extinguished.
Error:
It will be lightened when unit is under protection/error.
VACATION MODE:
For the outgoing vacation mode, the water tank is set
at
59 °F(
15°C). Maintains low tank water temperature,
preheats hot water and anti-freeze lines, while
reducing on/off operation of the tank.
15
1
3
5
12
10
6
11
8
2
13
1718 19
14
4
16
9
7
The heat pump and the electric heater are running at
the same time.
background
28
29
61 2
3 7 5
4
Any pressing of button is effective only under
button and display unlocked state.
Icon Description
Default ECONOMY mode
Switch to HEAT PUMP mode
Use this key to switch mode
Switch to HYBRID mode
Switch to VACATION mode
Adjust vacation days (1-360 days)
Switch to E-heater mode
Switch to ECONOMY mode
When the DR icon goes out, the DR
function is not turned on. Click this button
to turn on the DR function. After waiting
for it to turn on, the DR icon stays on.
DR button is valid once.
If you need to turn off the DR function,
you need to click the DR button again
while the DR is on and the device is on,
and the DR icon will turn off.
N0 Icon Description
11
E-HEATER MODE:
ECONOMY MODE:
HEAT PUMP MODE:
This icon will be lightened when the
appliance
is running
in HEAT PUMP MODE.
In this mode while the ambient temperature is at the heat
pump ambient operating range, heat pump will work if
T5U/T5L is lower than special parameter. If the ambient
temperature is out of the heat pump ambient operating
range, only the heating element will work (won't work at
the same time).
12
13
14
15
16
When any key is invalid, this icon will flash 3 sec.
The icon lights up when the water temperature is
being set.
The icon lights up when the clock is being set.
17
18
19
When the heat pump is operating and producing hot
water, the icon lights up.
Wireless:
(some units)
will be lightened when Wireless is connected;
will be extinguished when Wireless is not connected;
will flash with 2Hz frequency when setting Wireless.
HEAT PUMP ICON:
DR ICON:
2
1
This icon will be lightened when the appliance is running in
E-HEATER MODE.In this mode, only the heating element
will work (won't work at the same time).
After the DR function is enabled, if general curtailment,
basic load up, advanced load up, or critical curtailment
request is received, the icon DR will flash slowly; when
receiving the grid emergency request, the icon DR will
flash quickly
This icon will be lightened when the appliance is
running in ECONOMY MODE.
In this mode while the ambient temperature is at the
heat pump ambient operating range, heat pump will
work if T5U/T5L is lower than special parameter. And
upper heating element wil work when T5U is lower than
36℃. If the ambient temperature is out of the heat pump
ambient operating range, only the heating element will
work (won't work at the same time).
After the DR function is enabled, if
general curtailment, basic load up,
advanced load up, or critical
curtailment request is received, the
icon DR will flash slowly; when
receiving the grid emergency request,
the icon DR will flash quickly
If no user changes the device mode within
72 hours (except for VACATION mode and
HEATPUMP mode), it will automatically
switch to ECONOMY mode (72 hours is the
power on time).
background
29
INCREASE AND DECREASE
If screen is unlocked, corresponding value will
increase by pressing the button.
temperature value will be increased continuously;
clock/timer value will be increased continuously;
day value will be increased continuously;
On querying, check items will page up by pressing it
.
Engineering Mode
1) In the main interface, press and hold the key
for 3 seconds to enter the engineering mode; use
the up and down keys to switch the inspection
channel, and the attribute value of the channel will
be displayed when switching to the channel. By up
and down key, you can modify a parameter setting,
after setting and adjusting, press confirm key to
return to the main interface to make the setting
effective (ch
annel 2, 3, 4, 34, 35 will be effective
immediate
ly). Press the Return button to return to
the previous interface (channel selection interface).
After 30 seconds from the last operation of the up
and down buttons, or by pressing the return button
or the on/off button, you can directly exit the
engineering mode.
2
Engineering mode can be accessed in both
power-on and power-off state.
It is strictly prohibited for the customer to change the
parameter settings of other channels in the
engineering mode without authorisation to avoid
affecting the normal operation of the unit or causing
damage to the prototype.
Power on/off button
Press the button to turn the device on or off.
Icon Description
Query function
1) In the main interface, press the search to enter
the spot check function, and use the up and down
keys to switch the spot check channel, and the
attribute value of the channel will be displayed when
switching to the channel, and the specific channel
can be found in the function book.
2) After 30 seconds from the last operation of the up
and down keys, or by pressing the return key or the
on/off key, you can directly exit the engineering
mode;
3
Query mode can be entered in both power-on
and power-off state.
No Icon Description
CONFIRM/UNLOCK
If screen and buttons are unlocked, press it to upload
setting parameters after setting any parameter.
TIMER (Daily setting)
TIMER (Weekly setting)
1) Press the TIMER button to the day timer icon ,
press the confirmation button to enter the day timer
setting interface, the day timer has a total of 6 time
periods, each time period can be set to open the time,
close the time, mode, set the temperature of the water;
when set the first time period set the temperature of the
water, press the confirmation button to enter t
he next
time pe
riod of the set; when set the sixth time period set
the temperature of the water, press the confirmation
button to return to the main interface; during this period,
you can press the return button Return to the
previous setting or main interface;
2) When setting the on time and off time, press the delete
button , the time can be restored to the default value,
and displaying ( -. --
).
3) If there is a conflict between the set time periods, the
time period set at the back will be the valid time period,
and the time period in front will be the invalid time period;
the invalid time period restores the default setting
4) You can enter the daily timer setting in both power-on
and power-off state.
1) Press the TIMER button to the weekly timer icon ,
press the confirmation button to enter the weekly
timer setting interface, weekly timer a total of 7 days,
there are 6 time slots can be set each day, each time
slot can be set to open the time, close the time, the
mode, set the water temperature; when the first time
slot set the water temperature, press the confirmation
b
utton to enter the
next time slot settings; when the
sixth time slot set the temperature, press the confirma-
tion button to return to weekly After setting the water
temperature for the 6th period, press the confirmation
key to return to the selection of week; during this period,
you can press the return key to return to the previous
level of setting or the main interface;
2) When setting the
on time and off time, press the delete
button to restore the time, mode and set water
temperature to the default value, and displaying (-. --).
3) If you adjust the timing time again after the setting is
completed, then all the settings after the adjustment
time period will be canceled. For example, if you adjust
the timer on for time period 2, the timer off for time
period 2, and th
e settings for time periods 3, 4, 5, and 6
will al
l be canceled to (-:---) after adjustment. Mode and
setting water temperature become default values
(Energy saving mode, 60°C(140 °F).
4) In the weekly timer setting, in the weekly selection,
use the copy button , you can locate the setting of a
certain day to the base day, select other days, press the
copy button to change the status of the day,
the fast
flashing is selected, the slow flashing is unselected, and
a
fter pressing on the confirmation button, you can copy
the setting of the base day to the selected day;
5) You can enter the weekly timer setting in both power-on
and power-off state.
6
4
3
5
30
6
7
N0
N0
8
background
30
No.
Icon
Description
Setting the
date and
clock
Connecting
the wireless
function
1) In the main interface, long
press the on/off key for 3
seconds to enter the AP wireless
network mode, there will be a
wireless icon in the upper right
corner of the line controller. At
this time, enter the APP, select
the category of air water heater,
choose the correct model, and
then network according to the
APP prompts, and after the
network is completed, the
wireless icon will be always on;
(2) Wireless matching can last
up to 8 minutes, after 8 minutes,
if the matching is not succes
sful,
the wireless icon will go out;
3) Long press the delete button
for 8 seconds in the main
interface to reset the wireless
function;
4) It can be set in both power on
and power off state.
1) In the main interface, long
press the key combination for 2
seconds to ent
er the child lock
state;
(2) In the state of child lock, long
press the key combination again
for 2 seconds to release the child
lock state;
3) In the locked state, there will
be an icon next to the water
temperature display.
1) In the main interface, press
and hold the timer button for 3
seconds to enter the date
setting, press the up/do
wn
button to select the date, press
the confirmation button to
enter the clock setting, press
the up/down button to modify
the time, and press and hold to
accelerate the increase/de-
crease of the time. After
setting the clock, press the
confirm button to return to the
main interface to complete the
setting of date and time.
(2) After 30 seconds from the
last operation of the up/down
button or pressing the return
button or the power on/off
button, you can directly exit the
date and time setting;
3) Setting can be done in both
powe
r-on and power-off state.
Child lock
fun
ction
Press for 3 sec
+ +
Press for 2 sec
1.3 Combination button
31
background
31
32
Display
noitcAevitcerroCnoitpircseDnoitcnuflaM
EH0b
Tank and LCD panel communication error.
If the connection between LCD panei and PCB has released or
PCB has been broken.
EH00
Machine working parameters are abnormal. Contact a qualified person to service the unit.
EH03
DC fan fault.
If the connection between fan and PCB has released or fan has
been broken. Contact a qualified person to service the unit.
PH15
Electric leakage error. If PCB current_induction_circuit
check the current difference between L,N > 14mA,
system consider it as ”electric leakage error”.
If some wires have been broken or bad wire connection.
Contact a qualified person to service the unit.
EC54
Compressor discharge temperature sensor TP error.
If the connection between sensor and PCB has released or
sensor has been broken.
Contact a qualified person to service the unit.
EH5H
Compressor suction temperature sensor TH error.
EC53
Ambient temperature sensor T4 error.
EC52
Evaporator temperature sensor T3 error.
EH5L
Error of sensor T5L (lower water temperature sensor).
EH5U
Error of sensor T5U (upper water temperature sensor).
EHLA
When the ambient temperature T4 is out of the
compressor operating range, the compressor stops,
and EHLA is displayed until T4 returns to the normal
range. Only works on units without electric heaters.
Devices with electric heaters will never display “EH
LA”.
It is normal, and no necessary to repair.
EH5d
Electric heater open-circuit error.
If the electric heater has been broken or bad wire
connection after repair.
EHHP
Heat pump system fault. When PH20, PH21, PC30,
PC06 any protection appears 3 times or the
protection lasts 1 hour.
person to service the unit.
PHdH
.gnitaeherofebknatretawehtniretawsierehttahterusnE.noitcetorpgninrubyrD
PH20
Compressor abnormally stopped protection. The
discharge temperature is not so higher than evaporator
temperature after compressor running a term.
If the compressor broken or bad connection between
service the unit.
PH21
The working current of the compressor is too large.
If the compressor is broken, system blocked, air or water or
more refrigerant in system (after repair), water temperature
sensor malfunction, etc. Contact a qualified person to
service the unit.
PH24
Frost protection. T5L < 4°C(39.2 °F) and T4 < 7°C(44.6 °F) .
The cold water temperature is too low, which will affect the
water tank. The electric heater will work.
PC30
System high pressure protection
3.0 MPa active; 2.4 MPa inactive
If the system is blocked, air or water or more
refrigerant in system (after repair), water temperature sensor
malfunction, etc. Contact a qualified person to service the unit.
PC06
High TP protection. Tp > 105°C
(221°F)
.
Protection active; Tp < 90°C
(194°F)
Protection
inactive.
If the system blocked, air or water or less
refrigerant (leakage) in system (after repair), water
temperature sensor malfunction, etc. Contact a qualified
person to service the unit.
PH9b
Overtemperature protection. The current water
temperature exceeds the target temperature by
more than 5°C
(41°F)
.
The water temperature sensor is faulty or the current water
person to check.
PH91
Low T3 protection.
If the fault persists. Contact a qualified person to service the unit.
PH22
Chassis leakage protection.
Check if the chassis is leaking water. If there is any leakage.
Please clean and check the leakage portor contact after-
sales personnel.
PHL1
Leakage protection of the water tray.
Check if the drain tray is leaking. If there is any leakage. Please
clean and check the leakage port or contact after-sales personnel.
FC06
Electric ball valve malfunction.
Check if the electric ball valve is working properly. If it does
not work properly. Please replace it or contact after-sales
personnel.
The compressor works abnormally. Contact a qualified
PCB and compressor. Contact a qualified person to
temperature is too high. In case of burns, contact a qualified
background
32
CTA Module Wiring
CUSTOMER SERVICE
Water Heater Juntion Box
33
A qualified technician must install a separate branch circuit with copper conductors and an over current
protective device. He must also provided a suitable disconnecting means.
Please consult National Electrical Code ANSI/NFPA70 for wiring best practices.
Please consult local codes.
Install the Adaptor on the top right side of water heater (as shown in Fig8.1 ) .To gain access of the port,
remove 3 screws holding junction box cover and connect the Adaptor to the port.
Look at the manufacturer instuctions for the CTA2045(that is ACTA2045 compliant) .
WARNING
CTA Adaptor
Connection Port
Conduit
Connector
Ground
Screw
Wire
Connections
CTA Adaptor
Junction Box Cover (CTA2045)
(Not applicable
for all models)
Fig8.1
background
33
Hot Water Outlet
3/4” Tempered
domestic hot water
supply to house
Nominal 3/4” size mixing or
tempering valve (refer to warning
above). Follow mixing or tempering
valve manufacturer's instructions
for installation of the valve
Cold Water Inlet
Demand Response (CTA-2045) Installations
A thermostatic mixing valve conforming to ASSE 1017 shall be installed on the hot water supply line
following all manufacturer installation instructions.
34
Maximum and minimum inlet water operating temperatures 9°C~43°C;
Maximum and minimum inlet water operating pressures 0.3 MPa-1.03 MPa and flow rate 0.2-0.7(m /h);
3
background
34
35
Replacement Parts
Instructions For Placing a Parts Order
Address parts orders to the distributor or store
where the heater was purchased.
All parts orders should include:
1. The model and serial number of the water heater
from the rating plate located on the tank jacket.
2. Specify voltage and wattage as marked on the
rating plate.
3. Part description (as noted below) and number of
parts desired.
FLAMMABLE CONTENTS UNDER PRESSURE.
The compressor is not a serviceable part. The
compressor wiring terminals may are allowing
pressurized refrigerant and oil to escape, ignite and
cause serious bodily injury, severe burns or death.
Check the water heater’s rating label on the front of
the unit for the acceptable element wattage.
NOTICE
For your safety DO NOT attempt repair of electrical
wiring, heating elements, heat pump or electronic
controls. Refer repairs to qualified service personnel.
CAUTION
No. Name on Manual List
1 Air filter
2 Top cover
3 Front cover
4 Display box rear cover
5 Display box front cover
6 Display box assembly
7
Relay board E-box assembly
Relay board
No. Name on Manual List
17 Fan box assembly
Evaporator assembly
Expansion valve subassembly
20 Air discharge pipe assembly
Pressure switch
Compressor
Water Level Switch
23
Dry filter
HP Temperature sensors (T3,T4,TP)
8 Junction box subassembly
7.1
9 Junction box cover
10 Junction box cover(CTA-2045)
11 Main Control E-box assembly
Main Control E-box Lid Assembly
8.1
Wiring terminal
11.1
Main control board11.2
Compressor capacitor
Cover ofRelay board E-box
11.3
12
Motor holder assembly13
Suction line temperature sensor(TH)26
Drainage pipe27
Ground wire24.3
28
29
30
30.1
30.2
30.3
Compressor harness
Tank foaming assembly
Drainage tray
Insulating Cover(Upper)
Insulating Cover(Lower)
30.4
Cover(TCO)/Cover(Electric heater)
Fan motor
14
Suction pipe assembly
Axial Flow Fan
15
16 Ventilation ring
18
19
20.1
21
22
24
25
WARNING
background
35
Replacement Parts
Instructions For Placing a Parts Order
Address parts orders to the distributor or store
where the heater was purchased.
All parts orders should include:
1. The model and serial number of the water heater
from the rating plate located on the tank jacket.
2. Specify voltage and wattage as marked on the
rating plate.
3. Part description (as noted below) and number of
parts desired.
FLAMMABLE CONTENTS UNDER PRESSURE.
The compressor is not a serviceable part. The
compressor wiring terminals may are allowing
pressurized refrigerant and oil to escape, ignite and
cause serious bodily injury, severe burns or death.
Check the water heater’s rating label on the front of
the unit for the acceptable element wattage.
NOTICE
For your safety DO NOT attempt repair of electrical
wiring, heating elements, heat pump or electronic
controls. Refer repairs to qualified service personnel.
CAUTION
36
WARNING
Element heater30.6
30.10
30.10.1
TCO30.5
30.9
30.10.2
T&P valve
30.7
Water temperature sensor
Tank enamel assembly
Drain valve
Anode rod
Water outlet J-tube
Water inlet pipe assembly
30.8
30.10.3
background
36
1. Download NetHome Plus App
The following QR code is only available for downloading App. It is totally different with the QR code packed with unit.
Android Phone users: Scan Android QR code or go to google play, search “Nethome Plus” App and download it.
IOS users: Scan IOS QR code or go to APP Store, search “Nethome Plus” app and download it.
Android
IOS
The NetHome Plus App (cont.)
2. Register Or Login Account
Open the App and create a user account, if you
already have one, just log in.
3. Add Your Appliance
Tap the “+” icon to add home appliance to your
NetHome Plus account.
4. Choose Air Source Heat Pump Water
Heater
5. Connected To The Network
Follow the instructions in the app to set up the
Wireless connection.
If the network connection fails, please refer to
the App tips for operation.
The actual UI design may look different from
examples due to app updates. �
37
Ensure that your mobile phone is connected to the home
wireless network, the 2.4GHz band wireless signal is enabled on
your wireless router and you know the network password.
Turn on Bluetooth on your phone and the device
must also be powered up.
CAUTION
background
37
Cavity Insert Instructions
The following instructions are intended for qualified service personnel ONLY, and should only be done
when necessary.
In order to replace the ECO, thermistor or heating element, remove
the cavity insert crossbar by following the instructions below:
1. Disconnect all power to unit before to starting maintenance.
2. Remove the cap.
3. Replace the ECO, thermistor and/or element as necessary.
4. Recover the cap before turning on the power to the water
heater.
The cavity insert crossbar is necessary for the manufacturing
process only.
The removal of the crossbar will not interfere with the operation
of the water heater.
NOTICE
38
Press the button to reset
CAUTION
background
38
Wiring Diagram
CT2
CT1
AC mutual inductor
Zero-phase electricity mutual inductor
T4
T3
T5U
T5L
TP
TH
Suction temperature sensor
Ambient temperature sensor
Evaporator temperature sensor
Tank temperature sensor(Upper)
Tank temperature sensor(Lower)
Discharge temperature sensor
EEV
Emergency cut offECO
Electric expansive value
POWER IN
CT1
CT2
CN38
Main control board
CN18
PE
CN12
FAN-H
CN2
Alarm
CN53
CN10
CN51
CN36
CN24
CN28
T3
CN29
TH
CN1
T4
TP
CN14
EEV
CN19
DEBUG
CN41
TEST
CN20
EEPROM
Display
DC
FAN
EEV
Green or Y/G
UE
Gray
Blue
5
T5U/T5L
6
This symbol indicates the element isoptional,
the actual shape shall prevail.
Y/G
RY1
The L1, L2 wires, which get through the
zero-phase
electricity mutual inductor,must keeping the same
direction during wiring, otherwise, system malfunction
may caused.
C
Red
R
S
Compressor Capacitor
White
Blue
Compressor
Red
Red
Brown
Y/G
Blue
4
Relay board
RY5N
RY6N
RY5L
RY6L
N
L
P3P4
HEAT1N
HEAT1L
HEAT2N
HEAT2L
CN17
CN17
CTA2045 CN50
3
CTA2045
3
Black
Red P1P2
FUSE
4
3
2
1
LE
T5U
ECO
T5L
Black
White
Black
White
Black
White
Gray
Gray
Gray
Red
Red
L2
L1
L2L1
Blue
L1 L2
Black
White
Brown
Red
Blue
Brown
Red
Black
5
Brown
Water Tank
Water level Switch (Normally Closed)
To Water Tank (T5U/T5L)
To Water Tank (
Water level Switch)
CN37
2
2
4
4
6(5)
2
2
2
2
2
2
2
208VAC 60Hz
240VAC 60Hz
To Water Tank (DC MOTOR)
DC
MOTOR
2
6
*
*
2
2
PRO_H
Note 1:
Green
39
background
background
MD14IU-134A
16125300A19368

Specifications

Senville SENWH-HP65US Questions and Answers

Questions and Answers

Related Products