ROVSUN SF105-18G 27'' High 1400W 120V Electric Fireplace with Mantel & Remote

Product's Documents

Below are documents related to this product, you can read online or download:
SF105-18G photo

User Manual

This is the main product document for model SF105-18G.

The file format is pdf, 13 pages, you can download this manual here .

background
SF105-18G
MADE IN CHINA
ELECTRIC FIREPLACE
background
2
TableofContents
Safety Information..................................................................................3
Pre-installation.......................................................................................6
Assembly......................................................................................7
Operation.........................................................................................8
Using the Remote Control....................................................................11
Care and Maintenance..........................................................................12
Troubleshooting....................................................................................13
background
3
SafetyInformation
IMPORTANTSAFETYINFORMATION
PLEASEREADALLOFTHEINFORMATIONINTHISOPERATINGMANUAL,INCLUDING
ALLSAFETY,OPERATING,ANDMAINTENANCEINFORMATION.TOAVOIDTHE
POTENTIALRISKOFFIRE,ELECTRICSHOCK,ORINJURYTOPERSONS,
USERSSHOULDFOLLOWTHEDIRECTIONSANDWARNINGSINTHISMANUAL
1.Readallinstructionsbeforeusingthisheater.
2.Donotusethisheateroutdoors.
3.Thisheaterisnotintendedforuseinbathrooms,laundryareasandsimilarindoorlocations.Neverlocatethe
heaterwhereitmayfallintoabathtuborotherwatercontainer.
4.Donotrunthepowercordundercarpeting.Donotcoverthepowercordwiththrowrugs,runners,orthelike.
Arrangethepowercordawayfromtrafcareasandwhereitwillnotbetrippedover.
5.Todisconnecttheheater,turncontrolstooff,thenremovetheplugfromtheoutlet.
6.Connecttoproperlygroundedoutletsonly.Alwaysplugheatersdirectlyintoawalloutlet/receptacle.Never
usewithanextensioncordorrelocatablepowertap(outlet/powerstrip).
7.Topreventapossiblere,donotblockreboxairintakesortheexhaustinanymanner.Donotoperatethe
reboxonsoftsurfaces,likeabed,whereopeningsmaybecomeblocked.
8.Thereisathermostatlimiterinsidetheheater.Whentheinnertemperatureoverheatsorabnormalheating
occurs,thethermostatprotectivedevicecutsoffthepowersupplytoavoidreplacedamagedorriskofre.
9.Usethisheateronlyasdescribedinthismanual.Anyotherusenotrecommendedbythemanufacturermay
causere,electricalshock,orinjurytopersons.
background
4
SAVETHESEINSTRUCTIONS
WARNING
!
Therearenouserserviceablepartsinsidethereplace/heater,
Iftheunitappearstomalfunction,
turmtheunitoffandunplugtheunitfromthewallimmediately,andcontactCustomer.
WARNING
!
Thisheaterishotwheninuse.Toavoidburns,donotletbareskintouchhotsurfaces.
Ifprovided,usehandleswhenmovingthisheater,Keepcombustiblematerial,
suchasfurniture,pillows,bedding,papers,clothesandcurtains
atleast3f.t(0.9meters)fromthefrontoftheheaterandkeepthemawayfrom
thesidesandrear.
WARNING
!
Extremecautionisnecessarywhenanyheaterisusedbyornearchildrenorinvalids
andwhenevertheheaterisleftoperatingandunattended.
WARNING
!
Alwaysunplugtheheaterwhennotinuse.
WARNING
!
Donotoperateanyheaterwithadamagedcordorplugor
aftertheheatermalfunctions,hasbeendroppedordamagedinanymanner.
Returntheheatertoanauthorizedservicefacilityforexamination,
electricalormechanicaladjustment,orrepair.
WARNING
!
Donotinsertorallowforeignobjectstoenteranyventilationorexhaustopenings
asthismaycauseanelectricshockorre,ordamagetheheater.
WARNING
!
Aheaterhashotandarchingorsparkingpartsinside.
Donotuseinareaswheregasoline,paint,orammableliquidsareusedorstored.
CAUTION
!
Whiletheheaterisinuse,thetopcenterofthereplacecangethottothetouch,
andmaycauseseriousinjuryorburns.
Alwayssupervisesmallchildrenaroundthereplace/heater.
Donotplaceanyclothordecorationsovertheheateroutletofthereplace,
orotherwiseobstructtheheateroutletofthereplace,
asthismaycauseareandseriousinjurymayresult,
background
5
SafetyInformation(continued)
GROUNDINGINSTRUCTIONS
Thisproductmustbegrounded.Ifitshouldmalfunctionorbreakdown,groundingprovidesapathofleast
resistanceforelectriccurrenttoreducetheriskofelectricshock,Thisproductisequippedwithacordhaving
anequipment-groundingconductorandagroundingplug.Theplugmustbepluggedintoanappropriateoutlet
thatisproperlyinstalledandgroundedinaccordancewithalllocalcodesandordinances.
Thisheaterisforuseon120-voltcircuitsandhasagroundedplug.Anadapterisavailablefromyourlocal
electronicsstoreoronlinesupplierforconnectingthree-bladegrounding-typeplugstotwo-slotreceptacles.
Thegreengroundinglugextendingfromtheadaptermustbeconnectedtoapermanentground
suchasaproperlygroundedoutletbox.Theadaptershouldnotbeusedifathree-slotgroundedreceptacle
isavailable.
DANGER
!
Improperconnectionoftheequipment-groundingconductorcanresult
inariskofelectricshock.Checkwithaqualiedelectrician
orservicemanifyouareindoubtastowhethertheproductisproperlygrounded.
Donotmodifytheplugprovidedwiththeproduct.
Ifitwillnotttheoutlet,haveaproperoutletinstalledbyaqualiedelectrician.
Cover of Grounded Outlet Box
Grounding Pin
Adapter
Grounding Lug
Metal Screw
Cover of Grounded Outlet Box
background
6
Pre-installation
TECHNICAL SPECIFICATION
Model Number Description
19"*5.1"*17.5"
Dimensions(WxDxH)
Net Weight
Gross Weight
Power Rating
Voltage
Frequency
12.6 Ib
14.8 Ib
1400W
120V
60Hz
PACKAGE CONTENT
Fireplace Unit Remote Control Screw x5
background
7
Assembly
STEP 1
Take out the unit from the box and layout all the spare parts for easy assembly. Make sure all small items
are not left in packaging materials.
NOTE:
Do not attempt to install the unit from the front of the mantel. It will not t.
STEP 2
Carefully set the unit from the back of the mantel and center it in the opening.
Check the alignment and attach the unit of the mantel by inserting screws through the drilled holes
on the trim of the mantel.
background
8
Operation
󵿎Identifyingthecontrolpanel
Thecontrolpanelislocatedonthetoprightcornerofthereplace/heaterunit.
Thecontrolpanelcontainsthedisplayunit(1),functionindicator(2),timerfunction(3),heatercontrol(4),
amescontrol(5),andmainpower(6).
Thedisplayunit(1)displaysinformationabouttheamelevel,timer,andcurrenttemperature.
󵿎Understandingthefunctionindicator
Thefunctionindicator(2)hasthreesquareLEDS-red,green,andblue.TheredLEDindicatesthattheFahrenheit
temperatureheatingfunctionisrunning,thegreenLEDindicatesthattheCelsiustemperatureheatingfunction
isrunning,andtheblueLEDindicatesthatthetimerfunctionisengaged.
TothebottomofthethreeLEDS,istheinfraredreceivermodulewhichcommunicateswiththeremotecontrol
tocontroltheheater.
background
9
Operation
󵿎Usingthetimerfunction
Thetimerbutton(3)allowsyoutosettheamountoftimeyouwantthereplace/heatertorun.Thetimerbutton(3)
operatesboththeamesandtheheaterfunction.iftheheaterisoperatingwhenthetimerisset,thentheheater
isonthetimer.iftheamesareoperating,thenthetimerwillcontroltheames.ifboththeheaterandamesare
operatingwiththetimerset,thenthetimercontrolsboththeamesandtheheater.Pressingthebuttoninsequence
willsetthetimerforasetinterval.Thisintervalperiodisshowninthedisplay(1),inblue.Thesetintervals
aredisplayedinthistable.Thetimerintervalissetfromthetimetheintervalisselected.Thereisnoclockfunction
forturningtheheateroramesonoroffataspecictime.
󵿎Usingtheheatercontrol
Theheaterbutton(4)turnstheheateronoroff.Thereisnospeedsettingfortheheaterblower.lfyouputthe
heaterinastandbymode(turnoffbythemainpowerbutton6),theunitwillholdthesettingsinthememory.
Whenthepoweristurnedbackon,theheaterwillturnonatthesamesettings.
Whentheheatingfunctionturnson,pressandholdtheheaterbutton(4)forvesecondstoentertemperature
adjustmentmode.TheLEDindicatorisred.Inadjustmentmode,thedisplayunit(1)ashes(intervalis0.5second).
Thereare22levelstochangeFahrenheittemperature72°F—73°F...82°F—ON—62F—63F...71F.
Afterthisisset,thedisplay(1)willashvetimesandexitfromsettingstatus.
Ifidle,thedisplayturnsoffafter10seconds.
Withtheheateron,gentlypressandholdthemainpowerbuttonforvesecondstoentertemperature
convertingmode.TheLEDindicatorashesvetimesinredcolorthenchangestogreen.Inthisconvertingmode,
thedisplay(1)ashes(intervalis0.5second).Pressandholdtheheaterbutton(4)forvesecondstoenter
temperatureadjustmentmode.Thereare12levelstochangeCelsiustemperature
22C—23°c...27·C—ON—17C—18..21C.Afteriisset,thedisplay(1)ashesvetimes.Ifidle,thedisplayturnsoff
after10seconds.RepeatthesameprocesstoconvertCelsiustemperatureintoFahrenheittemperature.
ButtonPress
1stpress
2ndpress
3rdpress
4th press
5th press
6th press
7th press
8th press
TimerInterval Display
30Minutes
30
1Hour
2Hours
3Hours
4Hours
5Hours
6Hours
OFF
1h
2h
3h
4h
5h
6h
None
background
10
Operation
󵿎Usingtheamecontrol
Presstheamebutton(5)tosettheamesfordifferentlevelsofameheight.Theseamelevelsareshowninthe
display(1).Theamesettingsareasfollows:
ButtonPress
1stpress
2ndpress
3rdpress
4th press
FlameLevel Displayvalue
High
L3
Medium
Low
AllOff
L2
L1
None
FireplaceAppearance
FlamesHighest,LogsGlowHighest
FlamesMedium,LogsGlowMedium
FlamesLow,LogsGlowLow
FlamesOff,Logsoff
Regardlessofthepreviousamesetting,whenpoweredoffbythemainpowerbutton(6),
theameswillcomeoninL3mode(High)whenyouturntheheateron.
Whentheheaterfunctionturnson,theamelevelwillcyclethroughthe3differentlevelsettingscontinuously.
ButtonPress
1stpress
2ndpress
3rdpress
FlameLevel Displayvalue
High
L3
Medium
Low
L2
L1
FireplaceAppearance
FlamesHighest,LogsGlowHighest
FlamesMedium,LogsGlowMedium
FlamesLow,LogsGlowLow
󵿎Usingthemainpowerbutton
Pressthepowerbutton(6)toturnthereplace/heaterunitonandoft.
Pressthepowerbutton(6)oncetoturntheuniton.Pressagaintoturntheunitoff.
background
11
UsingtheRemoteControl
1.Non-rechargeablebatteriesarenottoberecharged.
2.Batteriesaretobeinsertedwiththecorrectpolarity.
3.Exhaustedbatteriesaretoberemovedfromtheproduct.
4.Alwayspurchasethecorrectsizeandgradeofbatterymostsuitable
fortheintendeduse.
5.Replaceallbatteriesofasetatthesametime..
6.Cleanthebatterycontactsandalsothoseofthedevicepriortobatteryinstallation.
7.Removebatteriesfromequipmentwhennotusedforanextendedperiodoftime.
WARNING
!
Donotingestbatteries.
NOTE:
Batterydisposal
Pleasealwaysdispose
ofbatteries atasuitable
recyclingpoint.
Flame Control
Heater Control
󵿎Using the Remote control
The operation of the remote control buttons work the same as button on the control panel.
󵾯Install the battery
For replacement batteries, use AAA batteries.
Press down and slide back cover off the battery compartment.
Insert two provided AAA batteries into the battery compartment making sure that the ends of the batteries
with the negative(-) symbols are against the springs in the battery compartment.
Replace the battery compartment cover, making sure it snaps into position.
Main Power
Time Control
Heater Down
Heater Up
background
12
Care and Maintenance
WARNING
!
Alwaysdisconnectfromthepowersupplybeforecleaningtheheater.
Firstturnoffthemain power.
Thenremovetheelectricalplugfromthewall outlet.
WARNING
!
Donotusethisreplaceinsertifanypartof ithasbeenunderwater.
Immediatelycallaqualied servicetechniciantoinspectthereboxand
replace anypartoftheelectricalsystemwhichhasbeenunderwater.
Theblowermotorandamemotorarepre-lubricatedforadurableusingtimeandneednofurtherlubrication
ormaintenance.Toremoveanyaccumulationofdustordebris,thesoftbrushattachmentofavacuumcleaner
shouldoccasionallybeusedtocleantheoutletgrilleofthefanheater.
Useasoft,cleancloththatwillnotscratchthesurfacewhendusting.
Useacleansoftclothdampenedwithwarmwatertocleanthereplacesurface.
D0NOTusehouseholdorabrasive cleaners,astheseproductsmaydamagethesurface.
Whencleaningtheglassviewingscreenuseanon-abrasivedampclothwithliquidcleanerorsoftsoap
ifnecessary;Don NOTusecleaningpowdersoranyothersubstancewithabrasives
sincethesesubstanceswillscratchglass.
Undernocircumstancesshouldthisproductbeoperatedwithabrokenorchippedglasspanel.
Donotstrikeorslamtheglass.
Intheeventthatyourapplianceisstainedorotherwisedamagedduringuse,werecommendthatyoucall
aprofessionaltoit.
Whennotinusepleaseunplugthecordfromtheoutlettopreventanydamageoraccidents.
background
13
Troubleshooting
Problem
Solution
Checkthattheunitisfullypluggedinto
astandard120Voutlet.
Pressthepowerbuttononthecontrolpanel.
Theunitdoesnotturnon.
Theunitison,butthereisnoameeffect. Openthebackpanelstocheckiftheame
spindlehas fallenofffromthespindlemotor.
Thereisavisibleameeffect,buttheheater
doesnot continuetoblowwarmairafterrepeatedly
turningontheheater.
Turnon/offtheheaterbuttonseveraltimesto
makesure itisinthe“ON”position.
Theheaterdoesnotwork,butthepower
andheaterswitchesareinthe“ON”position.
Turnallswitchestothe“OFF”positionandunplug
the unitfromthewalloutletfor5minutes.
After5minutesplugtheunitbackintothewalloutlet,
andoperateas normal.
Makesurethatnoobjectsareblockingtheair
ventsonthetopandonthefrontofyourreplace.
Changetheremotebattery.
Operateremotetransmitterataslowmeasuredpace.
Presstheremotecontrolbuttonswithanevenmotion
andgentlepressure.
Repeatedlypressingbuttonsinrapidsuccessionmay
causethetransmittertomalfunction.
Standclosertoyourreplace.
Removeobjectsthatmayblockyourremotecontrol's
abilitytocommunicatewithyourreplace.
Remotecontrolisnotworking.

Specifications

Indexed Terms: Electric Fireplace, Mantel

ROVSUN SF105-18G Questions and Answers

Questions and Answers

Related Products