Mrcool UHP18036-O Universal Series 36K BTU, 3 Ton, 18 SEER2, DC Inverter Heat Pump Condenser

Product's Documents

Below are documents related to this product, you can read online or download:
Installation Instruction Other Documents
UHP18036-O photo

Installation Manual

This is the main product document for model UHP18036-O. Additionally, the document applies to other Mrcool models: 840255587891, UHP18036-O, 24K, 30K, 48K, 60K

The file format is pdf, 56 pages, you can download this manual here .

background
MRCOOL® UNIVERSAL
®
Series Split System
INSTALLATION & OWNER’S MANUAL
MODELS:
UAH18*-O
UHP18*-O
Read this manual carefully before installation and keep it where
the operator can easily nd it for future reference.
Due to updates and constantly improving performance, the
information and instructions within this manual are subject to
change without notice.
Version Date: September 25, 2025
Please visit www.mrcool.com/documentation
to ensure you have the latest version of this manual.
This product utilizes R-454B refrigerant
background
mrcool.com1
CONTENTS
SAFETY ............................................................................................................................... 2
PACKING LIST .................................................................................................................... 9
INDOOR UNIT INSTALLATION ....................................................................................... 10
3.1 Product Overview .............................................................................................. 10
3.2 Installation Location ........................................................................................ 11
3.3 Installation Preparation & Precautions .......................................................... 12
3.4 Installation Mounting Positions....................................................................... 18
3.5 Airow Directions .............................................................................................. 18
3.6 Wire & Piping Connections ............................................................................... 19
3.7 Vertical Installation ........................................................................................... 22
REFRIGERANT PIPING CONNECTION ........................................................................... 23
CONFIRMATION OF INDOOR UNIT............................................................................... 26
5.1 Units without Electric Heat .............................................................................. 26
OUTDOOR UNIT INSTALLATION ................................................................................... 27
6.1 Location Selection ............................................................................................. 27
6.2 Drain Fitting ....................................................................................................... 28
6.3 Anchor Outdoor Unit ........................................................................................ 29
ELECTRICAL CONNECTIONS .......................................................................................... 31
7.1 Wiring Precautions ............................................................................................ 31
7.2 Wiring Overview ................................................................................................ 31
7.3 Outdoor Unit Wiring .......................................................................................... 32
7.4 Indoor Unit Wiring ............................................................................................. 33
7.5 Specic Wiring Methods ................................................................................... 33
7.6 DIP Switch Denitions ....................................................................................... 37
AIR EVACUATION ............................................................................................................ 44
8.1 Preparations & Precautions .............................................................................. 44
8.2 Evacuation Instructions ..................................................................................... 44
TEST RUN ......................................................................................................................... 45
9.1 Before Test Run .................................................................................................. 45
9.2 Test Run Instructions ......................................................................................... 45
POST-INSTALLATION ...................................................................................................... 46
10.1 Care & Maintenance ........................................................................................ 46
10.2 Troubleshooting ............................................................................................... 47
10.3 24V Signal Chart ................................................................................................ 49
10.4 Error Display (Indoor Unit) .............................................................................. 50
10.5 Error Display (Wired Controller) ..................................................................... 51
10.6 Error Display (Outdoor Unit) ........................................................................... 51
10.7 Quick Maintenance by Error Code ................................................................. 52
1
Contents
2
3
4
5
6
7
8
9
10
background
mrcool.com 2 2
Incorrect usage may cause serious damage or injury.
The symbols below are used throughout this manual to indicate instructions that should be followed closely
or actions that should be avoided to prevent death, injury, and/or property damage.
Safety Precautions
CAUTION
Indicates a medium level of risk which, if not avoided, may
result in death or serious injury.
Indicates a low degree of risk which, if not avoided, may
result in minor or moderate injury.
Indicates important information but not danger.
Read Before Using
WARNING
WARNINGS FOR PRODUCT INSTALLATION
INSTALLATION MUST BE PERFORMED BY AN AUTHORIZED DEALER OR SPECIALIST. DEFECTIVE
INSTALLATION CAN CAUSE WATER LEAKAGE, ELECTRICAL SHOCK, OR FIRE.
****ELECTRICAL WORK MUST BE COMPLETED BY A QUALIFIED ELECTRICAL TECHNICIAN****
DO NOT install the unit in a location that may be exposed to combustible gas leaks. If
combustiblegasaccumulatesaroundtheunit,itcouldcausere.
DO NOT turn on the power until the installation and all work has been completed.
DO NOT install a unit equipped with an auxiliary electric heater within 3 ft (1 m) of any
combustible materials.
1. Turn o the unit and disconnect the power before performing any installation or repairs. Failure to do so
can cause electric shock.
2. Installation must be performed according to the installation instructions. Improper installation could cause
water leakage, electrical shock, re, and could void the warranty. Contact an authorized service technician
for repair or maintenance of this unit. This appliance must be installed in accordance with national wiring
regulations.
3. Only use the included accessories, parts, and specied parts for installation. Using non-standard parts can
cause water leakage, electrical shock, re, and/or failure of the unit.
4. Install the unit in a rm location that can support the unit’s weight. If the location cannot support the unit’s
weight, or the installation is not done properly, the unit may drop and cause serious injury and damage.
5. Install the drainage piping according to the instructions in this manual. Improper drainage could cause
water damage to your home and/or property.
6. When moving or relocating the air conditioner, consult experienced service technicians for disconnection
and re-installation of the unit.
7. For detailed information of how to install the indoor and outdoor units to their respective supports, please
refer to the indoor unit installation and outdoor unit installation sections of this manual.
8. For units with a wireless network function, the USB device access, replacement, and maintenance
operations must be carried out by professional sta.
9. Refer to details further in this manual regarding installing the unit to its support.
NOTICE
SAFETY
1
background
mrcool.com3
SAFETY
1
WARNINGS FOR PRODUCT USE
DO NOT insertngers,rods,orotherobjectsintotheairinletoroutlet.Thiscouldcauseinjury,
since the fan may be rotating at high speeds.
DO NOT useammablesprayssuchashairspray,lacquerorpaintneartheunit,asthiscould
causereand/oranexplosion.
DO NOT operate the unit in places near or around combustible gases. Emitted gas may collect
around the unit and cause an explosion.
DO NOT allow children to play with the appliance. Children must be supervised around
the unit at all times.
DO NOT operate the unit in a room where it could be exposed to excessive amounts of water,
such as a bathroom or laundry room. Exposure to excessive water amounts can cause the
electrical components to short circuit.
DO NOT exposeyourbodydirectlytodirectcoolairowfromtheunitforaprolongedperiod
of time.
1. If the unit operates abnormally (emits strange noises or a burning smell), immediately turn o the unit
and disconnect the power in order to avoid electric shock, re, and/or injury. Call your local dealer, or
MRCOOL® tech support at (270) 366-0457, for further assistance.
2. If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room
in order to avoid an oxygen deciency.
3. In certain functional environments (such as kitchens and server rooms etc.), the use of specially designed
air-conditioning units is highly recommended.
4. This appliance can be used by children (8 years and older) and persons with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge if they have been given instruction concerning the
use of the appliance and understand the hazards involved.
5. Improper installation, adjustment, alteration, service, or maintenance can cause property damage,
personal injury or loss of life. Installation and service must be performed by a licensed professional HVAC
installer, service agency, or the gas supplier.
ELECTRICAL WARNINGS
****ELECTRICAL WORK MUST BE COMPLETED BY A QUALIFIED ELECTRICAL TECHNICIAN****
DO NOT share the power supply with other appliances. The unit must be installed on a dedicated
electricalcircuit.Animproperorinsucientpowersupplycouldcausereand/orelectrical
shock.
1. The product must be properly grounded during installation or electrical shock could occur.
2. Appropriate wiring standards, regulations, and the installation manual must be followed for all electrical
work.
3. If connecting power to xed wiring, an all-pole disconnection device must be incorporated in the xed
wiring in accordance with the wiring rules.
4. For all electrical work, fuse the specied cables. Connect cables tightly and clamp them securely to prevent
external forces from damaging the terminal. Improper electrical connections could overheat, causing re
and/or electrical shock.
5. All electrical connections must be made according to the Electrical Connection Diagram located on the
panels of the indoor and outdoor units.
6. All wiring must be properly arranged to ensure that the control board cover can close properly. If the
control board cover is not properly closed, it can lead to corrosion and cause the connection points on the
terminal to heat up, catch re, or cause electrical shock.
7. Only use the specied wire. If the wire is damaged, it must be replaced by the manufacturer, its service
agent, or similarly qualied person in order to avoid a hazard.
8. Disconnection must be incorporated in the xed wiring in accordance with the NEC, CEC, or local codes.
background
mrcool.com 4
4
SAFETY
1
WARNINGS FOR CLEANING & MAINTENANCE
DO NOT clean the unit with excessive amounts of water.
DO NOT cleanunitwithcombustiblecleaningagents,asthesecouldcausedeformationand/or
re.
1. Turn o the device and disconnect the power before cleaning. Failure to do this could result in electrical
shock.
TAKE NOTE OF FUSE SPECIFICATIONS
• The unit’s circuit board (PCB) is designed with a fuse to provide over-current protection. This fuse must be
replaced with an identical component if the existing fuse is blown.
• The specications of the fuse are printed on the circuit board, examples of such are T3.15AL/250VAC,
T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC, etc.
• NOTE: Only blast-proof ceramic fuses can be used.
CAUTION
DO NOT allow the air conditioner to operate for extended periods of time with the doors or
windows open, or in very high humidity.
DO NOT operate the air conditioner with wet hands, as this could cause electric shock.
DO NOT use device for any other purpose than its intended use.
DO NOT climbontoorplaceobjectsontopoftheoutdoorunit.
1. Make sure that water condensation can drain smoothly and unhindered from the unit.
2. Turn o the unit and disconnect the power if the unit will not be used for an extended period of time.
3. As with any mechanical equipment, contact with sharp metal edges can result in personal injury. Ensure
care is taken when handling the unit and any of its accessories by wearing gloves and protective clothing.
NOTE ON FLUORINATED GASES:
1. This unit contains uorinated greenhouse gases.
2. For specic information on the type of gas and the amount, please refer to the relevant label on the unit
itself.
3. Service, maintenance, and repair of this unit must be performed by a certied technician.
4. Product un-installation and recycling must be performed by a certied technician.
5. When checking the unit for leaks, maintain proper record-keeping of all checks.
NOTE ON STATIC PRESSURE:
The allowed static pressure range of the air conditioner on site refers to the table below:
Model 24K 30-36K 48-60K
Pressure 0-1.0 in.wc. (0-250Pa) 0-1.0 in.wc. (0-250Pa) 0-0.8 in.wc. (0-200Pa)
Units: Inch of Water Column (Pascals)
NOTE: The maximum functional total external static pressure cannot exceed the above range values.
The airow reduces signicantly with pressures above and beyond the maximum value. The system
design should allow for the increased resistance of lters as they become dirty.
ThedatabelowrepresentsthestaticpressuresatfullrequiredairowusedforAHRItesting:
Model 24K 30-36K 48-60K
Pressure 0.5 in.wc. (125Pa) 0.5 in.wc. (125Pa) 0.5 in.wc. (125Pa)
background
mrcool.com5
SAFETY
1
FLAMMABLE REFRIGERANT WARNINGS
1. The installation of pipe-work should be kept to a minimum and should be protected from physical damage.
2. Refrigerant pipes should comply with national gas regulations.
3. All mechanical connections and ventilation openings should be kept clear of obstruction.
4. Utilize proper disposal processes based on national regulations.
5. Any person involved with working on or breaking into a refrigerant circuit should hold a current valid
certicate from an industry-accredited assessment authority, which authorizes their competence to handle
refrigerants safely in accordance with an industry recognized assessment specication.
6. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the
supervision of the person competent in the use of ammable refrigerants.
7. Do not use any means to accelerate the defrosting process or to clean, other than those recommended by
the manufacturer.
8. The appliance shall be stored in a room without continuously operating ignition sources (for example: open
ames, an operating gas appliance, or an operating electric heater).
9. Do not allow foreign matter (oil, water, etc.) to enter the piping, and securely seal the opening by pinching,
taping, etc.
10. Do not pierce or burn.
11. Refrigerants may not contain an odor.
12. Working procedures that aect safety should only be carried out by competent persons.
13. The unit should be stored in a well-ventilated area where the room size corresponds to the room area as
specic for operation, and should be stored so as to prevent potential mechanical damage from occurring.
14. Joints should be tested with detection equipment with a capability of 5 g/year of refrigerant or better, with
the equipment in standstill and under operation or under a pressure of at least these standstill or operation
conditions after installation. Detachable joints should NOT be used in the indoor side of the unit (brazed,
welded joint could be used).
15. A leak detection system is installed. The unit must be powered except for service. For units with a refrigerant
sensor, the indoor unit will display an error code and emit a buzzing sound, the compressor of the outdoor
unit will immediately stop, and the indoor fan will start running. The service life of the refrigerant sensor
is 15 years. When the refrigerant sensor malfunctions, the indoor unit will display the error code "FHCC".
The refrigerant sensor cannot be repaired and can only be replaced by the manufacturer. It should only be
replaced with the sensor specied by the manufacturer.
16. Prior to beginning work on systems containing ammable refrigerants, safety checks are necessary
to ensure that the risk of ignition is minimized. For repairs to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the system.
17. Work should be undertaken under a controlled procedure so as to minimize the risk of a ammable gas or
vapor being present while the work is being performed.
18. All maintenance sta and others working in the local area should be instructed on the nature of work being
carried out. Avoid work in conned spaces.
19. The area should be checked with an appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially ammable atmospheres. Ensure that the leak detection equipment being
used is suitable for use with ammable refrigerants, i.e. no sparking, adequately sealed, or intrinsically safe.
20. If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate re
extinguishing equipment should be on site and readily available. Have a dry power or CO2 re extinguisher
adjacent to the charging area.
21. No person carrying out work in relation to a refrigerating system which involves exposing any pipe work
should use any sources of ignition in such a manner that it may lead to the risk of re or explosion. All
possible ignition sources, including cigarette smoking, should be kept suciently far away from the site
of installation, repairing, removing, and disposal, during which refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make
sure that there are no ammable hazards or ignition risks. "No Smoking" signs should be displayed.
22. Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or
conducting any hot work. A degree of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the
atmosphere.
background
mrcool.com 6
6
FLAMMABLE REFRIGERANT WARNINGS
23. Where electrical components are being changed, they shall be t for the purpose and to the correct
specication. At all times the manfacturer's maintenance ad service guidelines shall be followed. If in
doubt, consult the manufacturer's technical department for assistance. The following checks should be
applied to installations using ammable refrigerants:
• the actual refrigerant charge is in accordance with the room size within which the refrigerant containing
parts are installed;
• the ventilation machinery and outlets are operating adequately and are not obstructed;
• if an indirect refrigerating circuit is being used, the secondary circuits should be checked for the
presence of refrigerant;
• marking to the equipment continues to be visible and legible, marking and signs that are illegible
should be corrected;
• refrigeration pipe or components are installed in a position where they are unlikely to be exposed to
any substance which may corrode refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being corroded or are suitably protected
against being so corroded.
24. Repair and maintenance to electrical components shall include initial safety checks and component
inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it
is necessary to continue operation, an adequate temporary solution should be used.
25. Initial safety checks should include:
• that capacitors are discharged: this should be done in a safe manner to avoid the possibility of
sparking;
• that there are no live electrical components and wiring are exposed while charging, recovering, or
purging the system;
• that there is continuity of earth bonding.
26. Sealed electrical components should be replaced if damaged.
27. Intrinsically safe components should be replaced if damaged.
28. Check that wiring will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges, or
any other adverse environmental eects. The check shall also take into account the eects of aging or
continual vibration from sources such as compressors or fans.
29. Under no circumstances should potential sources of ignition be used in the search for or detection of
refrigerant leaks. A halide torch (or any other detector using a naked ame) should not be used.
The following leak detection methods are deemed acceptable for refrigerant systems. Electronic leak detectors
may be used to detect refrigerant leaks but, in the case of ammable refrigerants, the sensitivity may not be
adequate, or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.) En-
sure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detec-
tion equipment shall be set at a percentage of the LFL of the refrigerant and should be calibrated to the refrig-
erant employed, and the appropriate percentage of gas (25% minimum) is conrmed. Leak detection uids are
also suitable for use with most refrigerants but the use of detergents containing chlorine may react with the
refrigerant and corrode the copper work. Examples of leak detection uids are the bubble method, uorescent
method agents, etc. If a leak is suspected, all naked ames should be removed/extinguished. If a leakage of
refrigerant is found which requires brazing, all of the refrigerant should be recovered from the system, or iso-
lated (by means of shut-o valves) in a part of the system remote from the leak. See the following instructions
of removal of refrigerant.
30. When breaking into the refrigerant circuit to make repairs, or for any other purpose, conventional
procedures should be used. However, for ammable refrigerants, it is even more vital to follow best
practice. The following procedure should be adhered to:
• safely remove refrigerant following local and national regulations;
• evacuate;
• purge the circuit with inert gas;
• evacuate;
• continuously ush or purge with inert gas when using ame to open circuit;
• open the circuit
SAFETY
1
background
mrcool.com7
SAFETY
1
FLAMMABLE REFRIGERANT WARNINGS
31. The refrigerant charge should be recovered into the correct recovery cylinders if venting is not allowed by
local and national codes. For units containing ammable refrigerants, the system should be purged with
oxygen-free nitrogen to render the appliance safe for ammable refrigerants. This process might need to
be repeated several times. Compressed air or oxygen shall not be used for purging refrigerant systems.
For appliances containing ammable refrigerants, refrigerant purging should be achieved by breaking the
vacuum in the system with oxygen-free nitrogen and continuing to ll the working pressure is achieved,
then venting to atmosphere, and nally pulling down to a vacuum. This process should be repeated until
no refrigerant is within the system. When the nal oxygen-free nitrogen charge is used, the system should
be vented down to atmospheric pressure to enable work to take place. The outlet for the vacuum pump
should not be close to any potential ignition sources, and ventilation should be available.
32. In addition to conventional charging procedures, the following requirements should be followed:
• Work should be undertaken with appropriate tools only (in case of uncertainty, please consult the
manufacturer of the tools for use with ammable refrigerants).
• Ensure that contamination of dierent refrigerants does not occur when using charging equipment.
Hoses or lines shall be as shot as possible to minimize the amount of refrigerant contained in them.
• Cylinders should be kept upright.
• Ensure that the refrigeration system is grounded prior to charging the system with refrigerant.
• Label the system when charging is complete (if not already).
• Extreme care should be taken not to overll the refrigeration system.
• Prior to recharging the system, it should be pressure tested with oxygen-free nitrogen (OFN). The
system should be leak-tested on completion of charging but prior to commissioning. A follow-up leak
test shall be carried out prior to leaving the site.
33. Before carrying out this procedure, it is essential that the technician is completely familiar with the
equipment and all its detail. It is good recommended practice that all refrigerants are recovered safely.
Prior to the task being carried out, an oil and refrigerant sample should be taken in case analysis is
required prior to re-use of recovered refrigerant. It is essential that electrical power is available before the
task is commenced.
a. Become familiar with the equipment and its operation.
b. Isolate the system electrically.
c. Before attempting the procedure ensure that:
• mechanical handling equipment is available, if required, for handling refrigerant cylinders;
• all personal protective equipment is available and being used correctly;
• the recovery process is supervised at all times by a competent person;
• recovery equipment and cylinders conform to the appropriate standards
d. Pump down refrigerant system, if possible.
e. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of
the system.
f. Make sure that the cylinder is situated on the scales before recovery takes place.
g. Start the recovery machine and operate in accordance with instructions.
h. Do not overll cylinders (no more than 80% volume liquid charge).
i. Do not exceed the maximum working pressure of the cylinder, even temporarily.
j. When the cylinders have been lled correctly and the process completed, make sure that the cylinders
and equipment are removed from the site promptly and all isolation valves on the equipment are closed
o.
k. Recovered refrigerant should not be charged into another refrigeration system unless it has been
cleaned and checked.
34. Equipment shall be labeled stating that it has been decommissioned and emptied of refrigerant. The
label should be dated and signed. For appliances containing ammable refrigerants, ensure that there are
labels on the equipment stating the equipment contains ammable refrigerant.
background
mrcool.com 8
8
FLAMMABLE REFRIGERANT WARNINGS
35. When removing refrigerant from a system, either for servicing or decommissioning, it is good
recommended practice that all refrigerants are removed safely. When transferring refrigerant into
cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge is available. All cylinders to be used should
be designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders for the
recovery of refrigerant). Cylinders shall be complete with pressure-relief valve and associated shut-o
valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before
recovery occurs. The recovery equipment should be in good working order with a set of instructions
concerning the equipment that is at hand and should be suitable for the recovery of the ammable
refrigerant. If in doubt, the manufacturer should be consulted. In addition, a set of calibrated weighing
scales should be available and in good working order. Hoses should be complete with leak-free disconnect
couplings and in good condition. The recovered refrigerant should be processed according to local
legislation in the correct recovery cylinder, and the relevant waste transfer note arranged. Do not mix
refrigerants in recovery units and especially not in cylinders. If compressors or compressor oils are to be
removed, ensure that they have been evacuated to an acceptable level to make certain that ammable
refrigerant does not remain within the lubricant. The compressor body should not be heated by an open
ame or other ignition sources to accelerate this process. When oil is drained from a system, it should be
carried out safely.
36. An unventilated area where the appliance using ammable refrigerants is installed should be constructed
so that should any refrigerant leak, it will not stagnate so as to create a re or explosion hazard. If
appliances connected via an air duct system to one or more rooms below the ventilation requirements,
that room should never contain potential ignition sources. A ame-producing device may be installed
in the space if the device is provided with an eective ame arrest. Auxiliary devices which may be a
potential ignition source should not be installed in the duct work. Examples of such are hot surfaces with
a temperature exceeding 1292°F (700°C) and electric switching devices. Only auxiliary devices (such as
a certied heater kit) approved by the manufacturer or declared suitable with the refrigerant should be
installed in connecting ductwork. False or drop ceilings may be used as a return air plenum if a refrigerant
detection system is provided in the appliance and any external connections are also provided with a sensor
immediately below the return air plenum duct joint. Refrigerant sensors for refrigerant detection systems
should only be replaced with sensors specied by the manufacturer. A leak detection system is installed.
The unit must be powered except for service.
37. Transport of equipment containing ammable refrigerants should comply with transportation regulations.
38. Marking of equipment using signs should comply with local regulations.
39. Disposal of equipment using ammable refrigerants should comply with national regulations.
40. Storage of equipment/appliances should be in accordance with the manufacturer's instructions.
41. Storage of packed (unsold) equipment should be constructed so that mechanical damage to the equipment
inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of
equipment permitted to be stored together will be determined by local regulations.
Symbols Displayed on Indoor & Outdoor Unit
WARNING
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant
is leaked and exposed to an external ignition source, there is a risk of re.
CAUTION This symbol shows that the operation manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with
reference to the installation manual.
CAUTION
CAUTION
This symbol shows that information is available such as the operating manual or
installation manual.
SAFETY
1
background
mrcool.com9
2-Packing List
The listing below shows the accessories and parts (these may vary depending on purchase & options). Use all
of the installation parts and accessories to install the system. Improper installation may result in water leakage,
electrical shock, re, and/or equipment failure.
PART LOOKS LIKE QUANTITY
Installation & Owner's
Manual
1
Cable Ties
(Type A)
4
Insulation Sleeve 2
Flare Nut 2
Braze to Flare Adapter 2
Reusable Zip Ties
(Type B)
2
Adapter Cable
(For full 24V
communication)
1
Drain Joint 1
Seal Ring
(Will vary per condenser)
1
PACKING LIST
2
background
mrcool.com 10
10
INDOOR UNIT INSTALLATION
3
3.1 Product Overview
Operating Conditions
Cool Mode Heat Mode
Room
Temperature
60°F - 90°F
(16°C - 32°C)
32°F - 86°F
(0°C - 30°C)
50°F - 90°F
(10°C - 32°C)
Outdoor
Temperature
-22°F - 122°F
(-30°C - 50°C)
-22°F - 75°F
(-30°C - 24°C)
32°F - 122°F
(0°C - 50°C)
For units with auxiliary electric heater: When the
outside temperature is below 32°F (0°C), we strongly
recommend keeping the outdoor unit powered at all
times to prevent damage to equipment.
NOTE: Room relative humidity should be less than
80%. IF the unit operates in excess of this gure,
the surface of the unit may attract condensation.
Use the system under the following temperatures for safe and eective operation. If the unit is used under
dierent conditions, it may malfunction or become less ecient.
background
mrcool.com11
INDOOR UNIT INSTALLATION
3
3.2 Installation Location
Do NOT install the unit in the following locations:
CAUTION
Install the indoor and outdoor units, cables, and wires at least 3-1/5ft (1m) from televisions or radios
to prevent static or image distortion. Depending on the appliances, a 3-1/5ft (1m) distance may not be
sucient. The indoor unit must be electrically grounded per national and local electrical codes.
Environments with excessive
moisture, which can corrode
the equipment, electrical
components, and cause
electrical shorts.
Areas were there may be
detergent or other corrosive
gases in the air, such as
bathrooms or laundry
rooms.
Areas with
strong
electromagnetic
waves.
Areas that store
ammable
materials or gas.
Coastal areas
with high salt
content in the
air.
Areas where
the air inlet and
outlet may be
obstructed.
Areas with
oil drilling or
fracking.
Areas with danger
of explosion. Keep
ammable materials &
vapors, such as gasoline,
away from air handler.
Unit location MUST meet the following requirements:
; Securely install the indoor unit on a structure that
can support its weight. If the structure is too weak,
the unit may fall and cause personal injury, unit and
property damage, or death.
; Place air handler so that heating elements are at
least 18in (460mm) above the oor for a garage
installation. Failure to follow these instructions can
result in death, explosion, or re.
; The structure that the equipment is suspended from
must support the weight of the indoor unit.
; Enough room for
installation and
maintenance.
; Enough room for
the connecting
pipe and drainpipe.
background
mrcool.com 12
12
INDOOR UNIT INSTALLATION
3
3.3 Installation Preparation & Precautions
WARNING
There must be an airtight seal between the bottom of the air handler and the return air plenum. Use berglass
sealing strips, foil duct tape, caulking, or equivalent sealing method between the plenum and the air handler
cabinet to ensure a tight seal. Return air must not be drawn from a room where this air handler or any gas-
fueled appliance (i.e., water heater), or carbon monoxide-producing device (i.e., wood replace) is installed.
WARNING
• Please apply sealant around the places where the
wires, refrigerant pipes, and condensate pipes
enter the cabinet.
• Use duct tape or exible sealant to seal closed
any space around the holes where the drain lines
exit the cabinet. Warm air must not be allowed to
enter through any gaps or holes in the cabinet.
NOTE: Remove all accessories and packing in the air
outlet before installation.
Ductwork Acoustical Treatment
• Metal duct systems that do not have a 90 degree
elbow and 10ft (3m) of main duct to rst branch
takeo may require internal acoustical lining.
• As an alternative, brous ductwork may be used if
constructed and installed in accordance with the
latest edition of the SMACNA construction standard
on brous glass ducts.
• Both acoustical and brous ductwork shall comply
with the National Fire Protection Association as
tested by UL Standard 181 for Class 1 air ducts.
• The air supply and reutrn may be handled in one
of several ways; whichever situation is best suited
for the installation. A large number of issues
encountered with split-system installations can
be linked to improperly designed or installed duct
systems. It is therefore very important that the duct
system be properly designed and installed.
• Use of exible duct collars is recommended to
minimize the transmission of vibration/noise into
the conditioned space. Where the air duct is short,
or where sound is liable to be a problem, sound
absorbing glass ber should be used inside the
duct. Insulation of duct work must be installed
according to local codes and best practices. The
supply air duct should be properly sized by use of a
transition to match the unit opening. This unit is not
designed for non-ducted (free blow) applications.
NOTE: Duct work should be fabricated and installed
inaccordancewithlocaland/ornationalcodes.
background
mrcool.com13
INDOOR UNIT INSTALLATION
3
Indoor Unit Clearance Requirements
The distances between the mounted indoor unit
should meet the specications illustrated in the
following diagrams.
Vertical Installations
Mounting instructions: When installed vertically
(upow or downow), the lower end of the air outlet
needs to be connected to the L-shaped metal air
duct and fastened by screws. If return air is to be
ducted, install duct ush with oor. Set unit on oor
over opening. All return air must pass through coil.
Outlet side pipe length: 4.9 ft. (1.5m)
Dimensions
Dimensions
ModelCapacity(BTU/H)
24K 30K/36K 48K/60K
Length of A
49-3/4 in
(1263 mm)
54 in
(1371 mm)
56 in
(1421 mm)
Length of B
21-1/2 in
(546 mm)
21-1/2 in
(546 mm)
21-1/2 in
(546 mm)
Length of C
14-1/2 in
(368 mm)
17-1/2 in
(445 mm)
21-1/2 in
(546 mm)
Length of D
13 in
(330 mm)
16 in
(407 mm)
20 in
(508 mm)
Length of E
10-1/4 in
(273 mm)
10-1/4 in
(273 mm)
10-1/4 in
(273 mm)
background
mrcool.com 14
14
INDOOR UNIT INSTALLATION
3
Filter Dimensions
Filter must meet the requirements of UL900.
Model Capacity
(BTU/H)
Width
(W)
Depth
(D)
Thickness
(t)
24K
12 in
(305 mm)
20 in
(508 mm)
1 in
(25 mm)
30K/36K
16 in
(406 mm)
20 in
(508 mm)
1 in
(25 mm)
48K/60K
20 in
(508 mm)
20 in
(508 mm)
1 in
(25 mm)
Installation Position Requirements
Top View
Side View
Note on Ductwork & Connections
• Air supply and return can be handled in one of several ways depending on which is best suited for the
type of installation. Please see the dimensions on the previous page to determine duct inlet and outlet
connection sizes to match the air handler. The vast majority of problems encountered with combination
cooling systems can be linked to improperly designed or installed ductwork. For this reason, it is highly
important that the duct system be properly designed and installed.
• The use of exible duct collars will minimize the transmission of vibration and noise into the conditioned
space. In an installation where the return air duct is short, or where sound is likely to be a problem, a
sound absorbing liner should be used inside the duct.
• Insulation of the ductwork is a requirement anywhere it runs through an uncooled space during the
cooling season.
• The use of a vapor barrier is recommended to prevent absorption of moisture from the surrounding air
into the insulation.
• The supply air duct should utilize a properly sized transition in order to match the unit opening.
• All ducts should be suspended using exible hangers and never fastened directly to the structure. This unit
is not designed for non-ducted (free-blow) applications.
• Ductwork should be fabricated and installed in accordance with local and/or national codes.
background
mrcool.com15
CAUTION
• A eld-fabricated secondary drain pan (not included), with a drain pipe to the outside of the building is
required in all installations over a nished living space or in any area that may be damaged by overow
from the main drain pan. NOTE: A secondary drain pan is required for horizontal installations.
• This unit is not designed for non-ducted (free-blow) applications. Electric heat kit elements and/or blower
is easily accessible without ductwork and creates a safety hazard that could result in electric shock and/or
personal injury.
INDOOR UNIT INSTALLATION
3
Room Size Restriction
The units are connected via an air duct to one or more rooms, the bottom of the air outlet of the air duct in the
room should be at a height ≥7.3 ft (2.2m) from the oor. In UL/CSA 60335-2-40, the R454B refrigerant belongs to
mildly ammable refrigerants, which will limit the room area of the system service. Similarly, the total amount
of refrigerant in the system should be less than or equal to the maximum allowable refrigerant charge, which
depends on the room area serviced by the system.
Refrigerant Charge and Room Area Limitations
For the purpose of determination of room area (A) when used to calculate the maximum allowable refrigerant
charge (mmax) in an unventilated space, the following shall apply.
The room area (A) shall be dened as the room area enclosed by the projection to the oor of the walls,
partitions and doors of the space in which the appliance is installed. Spaces connected by only drop ceilings,
ductwork, or similar connections shall not be considered a single space.
For units mounted higher than 6 ft (1.8m), spaces divided by partition walls which are no higher than 5.3ft/1.6m
shall be considered a single space.
For xed appliances, rooms on the same oor and connected by an open passageway between the spaces can
be considered a single room when determining compliance to Amin, if the passageway complies with all of the
following:
• it is a permanent opening
• it extends to the oor
• it is intended for people to walk through
For xed appliances, the areas of the adjacent rooms, on the same oor, connected by a permanent opening
in the walls and/or doors between occupied spaces, including gaps between the wall and the oor, can be
considered a single room when determining compliance to Amin, provided all of the following are met:
• the space shall have appropriate openings
• the minimum opening area for natural ventilation Anvmin shall not be less than the following:
SECTION TERMINOLOGY
Mc: the actual refrigerant charge in the system
A: the actual room area where the appliance is
installed
Amin: the required minimum room area
Mmax: the allowable maximum refrigerant charge in
a room
Qmin: the minimum circulation airow
Anvmin: the minimum opening area for connected
rooms
TAmin: the total area of the conditioned space (for
appliances serving one or more rooms with an air
duct system)
TA: The total area of the conditioned space connected
by air ducts.
background
mrcool.com 16
16
INDOOR UNIT INSTALLATION
3
HeightofOutlet/m A/m
2
Mc/kg Mmax/kg Anvmin/m
2
2.2 5 5.0 2.685 0.045
2.2 6 5.0 2.941 0.042
2.2 7 5.0 3.177 0.038
2.2 8 5.0 3.396 0.035
2.2 9 5.0 3.602 0.031
2.2 10 5.0 3.797 0.028
2.2 11 5.0 3.983 0.024
2.2 12 5.0 4.160 0.020
2.2 13 5.0 4.330 0.016
2.2 14 5.0 4.493 0.013
2.2 15 5.0 4.651 0.009
2.2 16 5.0 4.803 0.005
2.2 17 5.0 4.951 0.001
NOTE
Take the Mc=5.0kg as an example. For appliances serving one or more rooms with an air duct system, the
room area calculation should be determined based on the total area of the conditioned space (TA) connected
by ducts taking into consideration that the circulating airow distributed to all the rooms by the appliance
integral indoor fan will mix and dilute the leaking refrigerant before entering any room.
When the openings for connected rooms are required, the
following conditions should be applied:
• the area of any openings above 11.81in (300mm) from the
oor should not be considered in determining compliance
with Anvmin.
• at least 50% of the required opening area Anvmin should be
below 7.87in (200mm) from the oor.
• the bottom of the lowest openings should not be higher
than the point of release when the unit is installed and not
more than 3.94in (100mm) from the oor.
• openings are permanent openings which cannot be closed
(for openings extending to the oor, the height should not
be less than .79in (20mm) above the surface of the oor
covering)
• A second higher opening should be provided. The total size
of the second opening should not be less than 50% of the
minimum opening area for Anvmin and should be at least
4.9ft (1.5m) above the oor. (NOTE: The requirement for
the second opening can be met by drop ceilings, ventilation
ducts, or similar arrangements that provide an airow path
between the connected rooms.)
• The room into which refrigerant can leak, plus the
connected adjacent room(s) should have a total area of no
less than TAmin.
• The room in which the unit is installed should not be less
than 20% TAmin.
Opening Conditions for Connected Rooms
(.79 in)
(11.81 in)
(7.87 in) (3.94 in)
(.79 in)
(4.9 ft)
background
mrcool.com17
INDOOR UNIT INSTALLATION
3
454B Refrigerant Charge Amount & Minimum Room Area
The unit matches the following table. The indoor and outdoor units are designed to be used together. Refer to
the unit you purchased. The minimum room area of operating or storage should be as specied in the following
table:
Model Indoor Unit Outdoor Unit
24K(208/230V) UAH18024-O UHP18024-O
30K(208/230V) UAH18030-O UHP18030-O
36K(208/230V) UAH18036-O UHP18036-O
48K(208/230V) UAH18048-O UHP18048-O
60K(208/230V) UAH18060-O UHP18060-O
MC or MREL
[oz/kg]
TAmin
[ft
2
/m
2
]
MC or MREL
[oz/kg]
TAmin
[ft
2
/m
2
]
MC or MREL
[oz/kg]
TAmin
[ft
2
/m
2
]
MC or MREL
[oz/kg]
TAmin
[ft
2
/m
2
]
<=62.7/1.776 12/1.1 134/3.8 126/11.67 211.6/6.0 198/18.43 289.2/8.2 271/25.18
63.5/1.8 60/5.53 141.1/4 132/12.29 218.7/6.2 205/19.04 296.3/8.4 278/25.8
70.5/2 66/6.14 148.1/4.2 139/12.9 225.8/6.4 212/19.66 303.4/8.6 284/26.41
77.6/2.2 73/6.76 155.2/4.4 145/13.51 232.8/6.6 218/20.27 310.4/8.8 291/27.63
84.6/2.4 79/7.37 162.2/4.6 152/14.3 239.9/6.8 225/20.88 317.5/9.0 298/27.64
91.7/2.6 86/7.99 169.3/4.8 159/14.74 246.9/7.0 231/21.5 324.5/9.2 304/28.26
98.8/2.8 93/8.6 176.4/5 165/15.36 254/7.2 238/22.11 331.6/9.4 311/28.87
105.8/3 99/9.21 183.4/5.2 172/15.97 261/7.4 245/22.73 338.6/9.6 317/29.48
112.9/3.2 106/9.83 190.5/5.4 179/16.58 268.1/7.6 251/23.34 345.7/9.8 324/30.10
119.9/3.4 112/10.44 197.5/5.6 185/17.2 275.1/7.8 258/23.96 352.7/10.0 331/30.71
127/3.6 119/11.06 204.6/5.8 192/17.81 282.2/8.0 264/24.57
Area
Formula
TAmin is the required minimum room area in ft
2
/m
2
.
MC is the actual refrigerant charge in the system in oz/kg.
MREL is the refrigerant charge in the system in oz/kg.
hinst is the height of the bottom of the unit relative to the oor of the room after installation.
WARNING: The minimum room area or minimum room area of conditioned space is based on releasable
charge and total system refrigerant charge.
When the unit detects a refrigerant leak, the minimum airow of the indoor unit is as follows:
Model 24K 30K 36K 48K 60K
Nomimal Air
Volume
400CFM
(680m
3
/h)
447CFM
(760m
3
/h)
541CFM
(920m
3
/h)
706CFM
(1200m
3
/h)
824CFM
(1400m
3
/h)
background
mrcool.com 18
18
INDOOR UNIT INSTALLATION
3
3.4 Installation Mounting Positions
The unit can be installed in a Vertical (downow or upow) or a Horizontal (right or left) conguration.
3.5AirowDirections
NOTE
• The unit can be installed vertical up and horizontal right
with no need to change the direction of the evaporator.
• The unit may be installed in upow, downow, left ow, or
right ow orientations.
NOTE
• Vertical Up and Horizontal Left installation does not require a change to the direction of the evaporator.
• For Horizontal installation, a secondary drain pan (not supplied) must be installed.
background
mrcool.com19
The steps below detail the installation of a downow or horizontal left indoor unit once it has been securely
mounted in place.
1. Remove the four
screws and open the
upper front panel.
2. Disconnect the
connectors.
3. Loosen three zip
ties (reusable).
4. Identify the position of the evaporator’s temperature sensor.
24K Model
3.6 Wire & Piping Connections
Follow these steps to perform an upow and horizontal right installation:
Step 1:
Remove the four screws and open the upper front panel.
Step 2:
Connect the wires according to the wiring diagram.
Step 3:
Connect the pipes and install the drainage pipes.
INDOOR UNIT INSTALLATION
3
30K-36K Model
48-60K Model
background
mrcool.com 20
20
INDOOR UNIT INSTALLATION
3
6. Take out the evaporator and drain pan and
rotate 180° (when your equipment needs to be
inaverticaldownconguration).
7. Reinstall the evaporator and drain pan.5. Remove the four screws and open the lower
front panel.
8. Relocate the wires in the coil module.
background
mrcool.com21
INDOOR UNIT INSTALLATION
3
NOTE: The wire body needs to pass through the wire
groove from the drain pan and attach to the hook of
the drain pan.
9. Relocate the wires in the fan module.
10. Connect the wires according to the wiring
diagram.
11. Reassemble the upper and lower front
panel.
CAUTION
• Insulate all piping to prevent condensation,
which could lead to water damage.
• The drainpipe is used to drain water away from
the unit. If the drainpipe is bent or installed
incorrectly, water may leak and cause a water-
level switch malfunction.
• In heat mode, the outdoor unit will discharge
water. Ensure that the drain hose is placed in an
appropriate area to avoid water damage and icy
conditions on walkways.
• DO NOT pull the drainpipe forcefully. This could
disconnect it.
NOTE: If installed above a nished living space, a
secondary drain pan (as required by many building
codes), must be installed under the entire unit
and its condensate drain line must be routed to a
location such that the user will see the condensate
discharge.
background
mrcool.com 22
INDOOR UNIT INSTALLATION
3
NOTICE ON PIPE PURCHASING
Installation requires PVC pipe or other suitable material per local and national codes. These can be found at
your local hardware store or dealer.
WARNING
• After removing the drain pan plug(s), check the drain hole(s) to verify that the drain opening is fully clear
and free of any debris. Also check to ensure no debris has fallen into the drain pan during installation that
could plug the drain opening. Apply sealant around the exiting drain pipe and the liquid and suction lines
to prevent the inltration of humid air.
• On units of this type in which the blower “draws” in air rather than “blows” air through the coil, traps must
be installed in the condensate drain lines (primary and auxiliary, if used). Traps prevent the blower from
drawing air through the drain lines into the air supply.
3.7 Vertical Installation
The unit operates with a negative pressure at the
drain connections and a drain trap is required. The
trap must be installed as close to the unit as possible.
Make sure the top of the trap is below the connection
to the drain pan to allow complete drainage of the
pan.
NOTE: A secondary drain or external drain pan may
be mandatory. Please refer to local codes.
NOTICE
Horizontal runs must also have an anti-siphon air vent
(standpipe) installed ahead of the horizontal run to
eliminate air trapping.
NOTE ON DRAINPIPE INSTALLATION:
• The gure shows how to trap or plug all drains during
vertical discharge.
• The gure shows how to trap or plug all drains during
right-hand discharge.
• The seal plug is supplied and should be screwed
tightly by hand only.
• Incorrect installation could cause water to ow back
into the unit and ood.
CAUTION
• The drainpipe outlet should be at least 2 in (5 cm)
above the ground.
• If it touches the ground, the unit may become
blocked and malfunction.
background
mrcool.com23
REFRIGERANT PIPING CONNECTION
4
WARNING ON REFRIGERANT PIPING
All eld piping must be completed by a licensed technician and must comply with all local and national
regulations.
• When the air conditioner is installed in a small room, precautions must be taken to prevent the refrigerant
concentration in the room from exceeding the safety limit.
• In the event of refrigerant leakage, if the refrigerant leaks and its concentration exceeds its proper limit,
hazards due to lack of oxygen may result.
• When installing the refrigeration system, ensure that air, dust, moisture, or foreign substances do not enter
the refrigerant circuit. Contamination in the system may cause poor operating capacity, high pressure in
the refrigeration cycle, explosion, or injury.
• Ventilate the area immediately if there is refrigerant leakage during the installation. Leaked refrigerant gas
is both toxic and may be ammable. Ensure there is no refrigerant leakage after completing the installation
work.
Name Model
PipeSpecication
Remark
Liquid Side Gas Side
Connecting Pipe
Assembly
24K Ø3/8in (Ø9.52mm) Ø3/4in (Ø19mm)
Pipes are not included
in the accessories and
need to be purchased
separately.
30K Ø3/8in (Ø9.52mm) Ø3/4in (Ø19mm)
36K Ø3/8in (Ø9.52mm) Ø3/4in (Ø19mm)
48K Ø3/8in (Ø9.52mm) Ø3/4in (Ø19mm)
60K Ø3/8in (Ø9.52mm) Ø3/4in (Ø19mm)
Air Handler Model AirHandlerUnitConnection(in.are)
Adapter Required at Indoor Unit
(in.aretobraze)
24K/30K/
36K/48K/60K
Liquid 3/8 3/8are-->3/8braze
Gas 3/4 3/4are-->3/4braze
Step 1: Cut Pipes
When preparing refrigerant pipes, take extra care
to cut and are them properly. This will ensure
ecient operation and minimize the need for future
maintenance.
• Measure the distance between the indoor and
outdoor units.
• Using a pipe cutter, cut the pipe a little longer than
the measured distance.
• Make sure that the pipe is cut at a perfect 90°
angle.
NOTE: Do not deform pipe while cutting. Be careful
not to damage, kink, or deform the pipe while cutting.
This will drastically reduce the heating performance.
Step 2: Remove Burrs
• Hold the pipe at a downward angle to prevent
burrs from falling into the pipe.
• Using a reamer or deburring tool, remove all burrs
from the cut section of the pipe.
Burrs can aect the air-tight seal of the refrigerant
piping connection. They must be completely removed.
background
mrcool.com 24
REFRIGERANT PIPING CONNECTION
4
Proper aring is essential to achieve an airtight seal.
• After removing burrs from cut pipe, seal the ends
with PVC tape to prevent foreign materials from
entering the pipe.
• Sheath the pipe with insulating material.
• Place are nuts on both ends of the pipe. Make
sure they are facing in the right direction, because
you can't put them on or change their direction
after aring.
• Remove PVC tape from ends of pipe when ready
to perform aring work.
Step 3: Flare Pipe Ends
• Clamp are form on the end of the pipe. The end
of the pipe must extend beyond the are form.
• Place aring tool onto the form.
• Turn the handle of the aring tool clockwise until
the pipe is fully ared.
Piping Extension Beyond Flare Form
Pipe Gauge
Tightening
Torque
Flare Dimension (A)
Min. Max.
Ø3/8in
(Ø9.52mm)
32-39 N.m
(320-390kgf.cm)
0.52in
(13.2mm)
0.53in
(13.5mm)
Ø3/4in
(Ø19mm)
67-101 N.m
(670-1010kgf.cm)
0.91in
(23.2mm)
0.93in
(23.7mm)
Flare Shape
• Remove the aring tool and are form, then
inspect the end of the pipe for cracks and even
aring.
Step 4: Connect Pipes
Connect the copper pipes to the indoor unit rst, then
connect it to the outdoor unit. First connect the low-
pressure pipe, then the high pressure pipe.
• When connecting the are nuts, apply a thin coat
of refrigeration oil to the ared ends of the pipes.
• Align the center of the two pipes that you will
connect.
• Tighten the are nut snugly by hand.
• Using a wrench, grip the nut on the unit tubing.
• While rmly gripping the nut, use a torque wrench
to tighten the are nut according to the torque
valves in the table above.
NOTICE
Use both a crescent wrench and a torque wrench
when connecting or disconnecting pipes to/from the
unit.
CAUTION
Be sure to wrap insulation around the piping. Direct
contact with the bare piping may result in burns or
frostbite.
• Make sure the pipe is properly connected. Over
tightening may damage the bell mouth and
under tightening may lead to leakage.
background
mrcool.com25
REFRIGERANT PIPING CONNECTION
4
NOTICE-MINIMUM BEND RADIUS
Carefully bend the tubing in the middle according to
the diagram below. DO NOT bend the tubing more
than 90° or more than 3 times.
• After connecting the copper pipes to the indoor
unit, wrap the power cable, signal cable, and the
piping together with binding tape.
NOTICE
DO NOT intertwine or cross the signal cable with any
other wiring.
• Thread this pipeline through the wall and connect
it to the outdoor unit.
• Insulate all the piping, including the valves of the
outdoor unit.
• Open the stop valves of the outdoor unit to start
the ow of the refrigerant between the indoor and
outdoor unit.
CAUTION
Check to make sure there is no refrigerant leak after
completing installation work. If there is a refrigerant
leak, ventilate the area immediately and evacuate
the system (refer to Air Evacuation section of this
manual).
Insulation Sleeve
After the unit is
installed, wrap the
piping and brass
tting with foam
tape.
You need to wrap all the connected copper
pipes, nuts, and other metal parts tightly into the
insulation.
Correct Refrigerant Piping Installation Methods:
Model Capacity
(BTU/H)
Maximum
Length of Piping
Maximum
Drop Height
24K/30K 164 ft (50 m) 82 ft (25 m)
36K/48K/60K 246 ft (75 m) 98.4 ft (30 m)
Maximum length and drop height
background
mrcool.com 26
CONFIRMATION OF INDOOR UNIT
5
Unit
Size
Volts-Phase Rated Current (A) Minimum Circuit Amps
Branch Circuit
Minimum Wire
Size AWG
Fuse/Circuit
Breaker Amps
24K 115/208/230V-1
115V: 6.0A 115V: 8.0A
14#
115V: 15.0A
208/230V: 4.0A 208/230V: 5.5A 208/230V: 15.0A
30K 115/208/230V-1
115V: 7.5A 115V: 10.0A
14#
115V: 15.0A
208/230V: 4.5A 208/230V: 6.0A 208/230V: 15.0A
36K 115/208/230V-1
115V: 7.5A 115V: 10.0A
14#
115V: 15.0A
208/230V: 4.5A 208/230V: 6.0A 208/230V: 15.0A
48K 115/208/230V-1
115V: 14.0A 115V: 17.5A
14#
115V: 20.0A
208/230V: 8.5A 208/230V: 11.0A 208/230V: 15.0A
60K 115/208/230V-1
115V: 14.0A 115V: 17.5A
14#
115V: 20.0A
208/230V: 8.5A 208/230V: 11.0A 208/230V: 15.0A
Use copper wire only to connect the unit. If other than uncoated (non-plated) 75°C copper wire (solid wire for
10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the National
Electric Code (ANSI/NFPA 70).
NOTICE
The specication may be dierent between dierent models. Refer to the indoor unit’s nameplate. Choose the
cable type according to the local electrical codes and regulations. Choose the correct cable size according to
the Minimum Circuit Ampacity indicated on the nameplate of the unit.
5.1 Units without Electrical Heat
background
mrcool.com27
OUTDOOR UNIT INSTALLATION
6
6.1 Location Selection
Proper Installation Locations Meet the Following Standards:
; Meets all spatial requirements shown in Installation requirements above.
; The location can support
the unit & won't vibrate.
; Good air circulation &
ventilation.
NOTE: Install the unit by following local codes and regulations, which may dier between dierent regions.
CAUTION: SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
If the unit is exposed to heavy wind:
Install the unit so that the air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in
front of the unit to protect it from extremely heavy winds.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air ow around the unit.
If the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist corrosion.
DO NOT install the unit in the following locations:
ǿ Near an obstacle that will block air inlets & outlets.
ǿ Near a public street, crowded areas, or where noise
from the unit will disturb others.
ǿ In a location exposed to large amounts of dust.
ǿ Near animals or plants that will be harmed by hot air
discharge.
ǿ Near any source of combustible gas.
; Where snowfall is
anticipated, take
appropriate measures to
prevent ice buildup & coil
damage.
; Noise from the unit will
not disturb other people.
Before installing the outdoor unit, you must choose an appropriate location. The following are standards that
will help you choose an appropriate location for the unit.
; The outdoor unit must
be installed on risers of
at least 6in.(15cm) in
height (or per local code)
above snowfall.
background
mrcool.com 28
OUTDOOR UNIT INSTALLATION
6
Step 2:
• Fit the rubber seal on the end of the drain tting that will connect to the outdoor unit.
• Insert the drain tting into the hole in the base pan of the unit. The drain tting will click into place.
• Connect a drain hose extension (not included) to the drain tting to redirect water from the unit during
heating mode.
IN COLD CLIMATES
In cold climates, make sure that the drain hose is as vertical as possible to ensure swift water drainage. If
water drains too slowly, it can freeze inside the hose and ood the unit.
6.2 Drain Fitting
Step 1:
Find the base pan hole on the outdoor unit.
background
mrcool.com29
The outdoor unit can be anchored to the ground or to a wall-mounted bracket with an M10 bolt. Prepare the
installation base of the unit according to the dimensions below.
Model
Outdoor Unit Dimensions Mounting Dimensions
W H D A B
mm inch mm inch mm inch mm inch mm inch
24K 890 35 673 26-1/2 342 13-15/32 663 26-1/8 354 13-15/16
30/36K 946 37-1/4 810 31-29/32 410 16-5/32 673 26-1/2 403 15-7/8
48K/60K 980 38-19/32 975 38-3/8 415 16-11/32 616 24-1/4 397 15-5/8
6.3 Anchor Outdoor Unit
OUTDOOR UNIT INSTALLATION
6
background
mrcool.com 30
9.8in
(25cm)
or more
9.8in
(25cm)
or more
59in
(150cm)
or more
23.6in
(60cm)
or more
118in
(300cm)
or more
L A
L≤H
L≤1/2H 25cm/9-13/16inormore
1/2H<L≤H 30cm/11-13/16inormore
L > H Cannot be installed
Rows of Series Installation
The relations between H, A, and L are as follows:
If installing the unit on the ground or concrete
mounting platform, do the following:
• Mark the positions for four expansion bolts based
on the dimensions chart.
• Pre-Drill holes for expansion bolts.
• Place a nut on the end of each expansion bolt.
• Hammer expansion bolts into the pre-drilled holes.
• Remove the nuts from expansion bolts, and place
the outdoor unit on bolts.
• Put a washer on each expansion bolt, then replace
the nuts.
• Using a wrench, tighten each nut until snug.
If installing the unit on a wall-mounted bracket,
do the following:
• Mark the position of the bracket holes based on
the dimensions chart.
• Pre-Drill holes for expansion bolts.
• Place a washer and nut on the end of each
expansion bolt.
• Thread expansion bolts through the holes in the
mounting brackets, put mounting brackets into
position, and hammer the expansion bolts into
the wall.
• Check that the mounting brackets are level.
• Carefully lift the unit and place its mounting feet
on brackets.
• Bolt the unit rmly to the brackets.
• If allowed, install the unit with rubber isolator
pads to reduce vibrations and noise.
WARNING
WHEN DRILLING INTO CONCRETE, EYE PROTECTION
IS RECOMMENDED AT ALL TIMES.
CAUTION
Make sure the wall is made of solid brick, concrete,
or of similarly strong material. The wall must be able
to support at least four times the weight of the unit.
OUTDOOR UNIT INSTALLATION
6
background
mrcool.com31
ELECTRICAL CONNECTIONS
7
WIRING WARNINGS
Before performing any electrical work, read these warnings:
• BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.
• All wiring must comply with local and national electrical codes, regulations, and must be installed by a licensed
electrician.
• All electrical connections must be made according to the Electrical Connection Diagram located on the panels
of the indoor and outdoor units.
• If there is a serious safety issue with the power supply, stop work immediately. Do not resume the install until
the safety issue is properly resolved.
• Power voltage should be within 90-110% of rated voltage. Insucient power supply can cause malfunction,
electrical shock, or re.
• Installation of an external surge suppressor at the outdoor disconnect is recommended.
• If connecting power to xed wiring, a switch or circuit breaker that disconnects all poles and has a contact
separation of at least 1/8in (3mm) must be incorporated in the xed wiring. The qualied technician must use
an approved circuit breaker or switch.
• Only connect the unit to an individual branch circuit. Do not connect another appliance to that circuit.
• Make sure to properly ground the unit.
• Every wire must be rmly connected. Loose wiring can cause the terminal to overheat, resulting in product
malfunction and possible re.
• Do not let wires touch or rest against refrigerant tubing, the compressor, or any moving parts within the unit.
• To avoid getting electric shock, never touch the electrical components soon after the power supply has
been turned o. After turning o the power, always wait 10 minutes or more before you touch the electrical
components.
• Ensure electrical wiring does not cross with signal wiring. This may cause distortion, interference, or possibly
damage the circuit boards.
• No other equipment should be connected to the same power circuit.
• Connect the outdoor wires before connecting the indoor wires.
• The diagrams are for explanation purpose only. Your machine may be slightly dierent. The actual diagram
shall prevail.
• Select a service disconnect as required by local, regional, and national codes.
7.2 Wiring Overview
7.1 Wiring Precautions
(purchased separately)
(purchased separately)
(purchased separately)
(purchased separately)
background
mrcool.com 32
ELECTRICAL CONNECTIONS
7
7.3 Outdoor Unit Wiring
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.
Prepare the cable for connection
Step 1:
1. Choose the right cable size according to the
local electrical codes and regulations, and the
Minimum Circuit Ampacity indicated on the unit
nameplate.
2. Using wire strippers, strip the jacket from both
ends of the signal cable to reveal approximately
5.9in (15cm) of wire.
3. Strip the insulation from the ends.
4. Stranded wire requires u-lugs or ring terminals to
be crimped onto the ends of the wire.
NOTICE
• When connecting the wires, strictly follow the
wiring diagram found inside the electrical box
cover.
• Choose the cable type according to the local
electrical switches and regulations.
• Choose the right cable size according to the
Minimum Circuit Ampacity indicated on the
nameplate of the unit.
Step 2:
Remove the electrical box cover of the outdoor unit.
If there is no cover on the outdoor unit, take o the
bolts from the maintenance board and remove the
protection board.
Step 3:
1. Match the wire colors/labels with the labels on the
terminal block. Firmly screw the u-lug of each wire
to its corresponding terminal.
2. Clamp down the cable with the cable clamp.
3. Insulate unused wires with electrical tape. Keep
them away from any electrical or metal parts.
4. Reinstall the cover of the electric control box.
WARNING
• RISK OF ELECTRIC SHOCK CAN CAUSE INJURY
OR DEATH. DISCONNECT ALL REMOTE ELECTRIC
POWER SUPPLIES BEFORE SERVICING.
• ISOLATE THE POWER SUPPLY LEADS AND
COMMUNICATION LEADS BY THE STRAIN RELIEF
AND KEEP POWER SUPPLY LEADS AWAY FROM
COMMUNICATION LEADS.
Step 4:
1. Remove the wire cover from the unit by loosening
the 3 screws.
2. Remove caps on the conduit panel.
3. Mount the conduit tubes (not included) on the
conduit panel.
4. Properly connect both the power supply and low
voltage lines to the corresponding terminals on
the terminal block.
5. Ground the unit in accordance with local switches.
6. Be sure to size each wire allowing several inches
longer than the required length for wiring.
background
mrcool.com33
7.4 Indoor Unit Wiring
WARNING
ISOLATE THE POWER SUPPLY LEADS AND COMMUNICATION LEADS BY THE STRAIN RELIEF AND KEEP POWER
SUPPLY LEADS AWAY FROM COMMUNICATION LEADS.
Step 1: Prepare the cable for connection.
1. Using wire strippers, strip the rubber jacket from both ends of the signal cable to reveal about 5.9in (15cm)
of the wire.
2. Strip the insulation from the ends of the wires.
Step 2: Open the front panel.
Using a screwdriver, remove the cover of the electric control box on your indoor unit.
Step 3: Connect the wires to the terminals.
1. Thread the power cable and the signal cable through the wire outlet.
2. Match the wire colors/labels with the labels on the terminal block. Firmly screw the wires of each wire to its
corresponding terminal. Refer to the Serial Number and Wiring Diagram located on the cover of the electric
control box. Terminal block wiring: when using 208V or 230V, connect L1 and L2. When using 115V, connect
L1 and L2. (L2 is used as N.)
3. Clamp down the cable with the cable clamp. The cable must not be loose or pull on the u-lugs.
4. Reattach the electric box cover.
CAUTION
• While connecting the wires, strictly follow the wiring diagram.
• The refrigerant circuit can become very hot. Keep the interconnection cable away from the copper tube.
• The holes on the cover of the electronic control box must be threaded through with armored wires.
ELECTRICAL CONNECTIONS
7
background
mrcool.com 34
ELECTRICAL CONNECTIONS
7
7.5SpecicWiringMethods
WARNING
Please refer to the wiring nameplate for the wiring method. Do not connect the power cord to the
communication line, as this may damage the system.
When using a 24V thermostat, please refer to the non-communicating wiring diagrams that follow:
Connection Method C: The following wiring diagrams are suitable for the AHU and ODU with a 24V thermostat.
Non-Communication Scheme Wiring Reference:
Note: The adapter cable must be used when the full 24V communication scheme is applied. It will stop the
operation of the outdoor unit if a refrigerant leak is detected.
Wiring for 3H & 2C Thermostat:
Wiring for 2H & 2C Thermostat:
Wiring for 2H & 1C Thermostat:
Wiring for 1H & 1C Thermostat:
background
mrcool.com35
ELECTRICAL CONNECTIONS
7
Optional Function Wiring:
CondensateOverowSwitch:
The unit will accommodate a remote condensate
overow switch. To enable, remove jumper J7 and
connect the installer-provided condensate overow
device to CN23 per below. When an overow
condition is present, the device should open
connection signaling the unit to turn o the system.
Fault Warning:
Alarm Output:
An alarm output (CN33) can be utilized if actions are
required when a fault is present. This is a passive
outlet port, so you will need to input a voltage signal.
The relay is normally open for normal operation, and
closed when a fault condition is active.
HumidierControl:
To connect a humidier, utilize the passive signal
“WORK” output (CN23) port as well as the R and C
wires on the controller, and wire the humidistat and
humidier per above wiring diagram. When the fan
is running, the CN23 relay will be closed, which will
allow power to the humidier when the humidistat
is below the humidity set point. If the thermostat or
zone controller has an HUM interface, connect the
humidier directly to the HUM and C ports.
background
mrcool.com 36
ELECTRICAL CONNECTIONS
7
UV, Fresh Air, or Ion Generator Wiring:
The WORK port is linked with the fan. When the fan is
running, the relay is closed
Control Logic
Indoor Unit Connector
Connector Purpose
R 24V Power Connection
C Common
G Fan Control
Y1 Low Demand Compressor
Y/Y2 High Demand Compressor
B Heating Reversing Valve
W Heating Control
W1 Stage 1 Electric Heating
W2 Stage 2 Electric Heating
E/AUX Emergency Heating
DH/BK Dehumidication/Zoning Control
DS Reserved Signal
L System Fault Signal
Outdoor Unit Connector
Connector Purpose
R 24V Power Connection
C Common
Y1 Low Demand Compressor
Y2 High Demand Compressor
B Heating Reversing Valve
W Heating Control
D Defrost Control
L System Fault Signal
LED Display
The control displays unit status as well as any
active fault codes on the LED display. If the unit
is functioning normally, the LED will display the
current temperature set point. When a fault code is
active, the display will quickly ash the active fault
code. Refer to the fault code table located in the
troubleshooting section of the manual for detailed
fault code information.
KEY1 Instructions (For Wired Controller Only):
• Press KEY1 to enter the forced automatic mode.
Press KEY1 again to enter the forced cooling
mode (LED display FC), and press KEY1 again to
shut down.
• Long press KEY1 under forced cooling mode (LED
display FC) for 5 seconds to enter forced defrost
mode.
background
mrcool.com37
7.6DIPSwitchDenitions
ELECTRICAL CONNECTIONS
7
background
mrcool.com 38
ELECTRICAL CONNECTIONS
7
Function DIP Switch Settings:
The 24V thermostat modes must refer to the following settings:
Function Combination Table of SW1-1 and SW1-4:
SW4-1 000isthedefault000/001/010/011/100
/101/110/111,internalmachineswith
dierentabilities,electricheating,
andPSCclassicationforuse.
SW4-2
SW4-3
SW1 Control Type IDU and ODU Connection Note
Wired Controller / 24V
Thermostat
(S1+S2) / 24V Connection Auto Discovery
Wired Controller S1+S2 Scenario 2
24V Thermostat S1+S2 Scenario 1
24V Thermostat 24V Connection Scenario 3
background
mrcool.com39
ELECTRICAL CONNECTIONS
7
Indoor Unit Dial Code
No.
Dial
Code
Control
Scenario
Function ON OFF Note
1 SW1-2 1, 2, 3
Anti-cold blow protection
option
NO [Default] YES
2 SW1-3 1, 2, 3
Single cooling/heating and
cooling options
Cooling [Default] Cooling & Heating
3 SW2-1 1
Compressor Running
(demand working with heat
pump+electric heat)
Compressor slower speed [Default] Faster Compressor
Only aects
compressor
and W1
4 SW2-1 2
Temperature dierential to
activate rst stage auxiliary
heat (the GAP of T1 and Ts),
Wire controller demand with
heat pump+electric heat
working together
2°F (1°C) [Default] 4°F (2°C)
5 SW2-2 2 Electric heat on delay YES [Default] NO
6 SW2-3 2
Electric auxiliary heating delay
to start time
30 minutes [Default] 15 minutes
Based on
SW2-2 is ON.
7 SW2-4 1 Compressor
The operation of the heat pump is limited by the outdoor
temperature, and the operation of auxiliary heat is not limited.
The system makes judgments according to the following rules:
1) The compressor cannot be operated hwen the outdoor
temperature is lower than the S3 rotary switch.
2) The compressor can be operated when the outdoor
temperature is ≥ S3 Rotary switch temperature +35.6°F (2°C).
SW2-4 and
S3 need to
be working
together.
8 SW2-4 2
Compressor/Auxiliary heat
outdoor ambient lockout
The operation of heat pump
is limited by the outdoor
temperature, and the operation
of auxiliary heat is not limited.
The system makes judgments
according to the following rules:
1) The compressor can be
operated when the outdoor
temperature is ≥S3 Rotary
switch temperature +35.6°F
(2°C).
2) The compressor cannot be
operated when the outdoor
temperature is lower than the
S3 rotary switch temperature.
[Default] Only one heat
pump or auxiliary heat can
be operated. The system
makes judgment according
to the following rules:
1) When the outdoor
temperature is lower
than the S3 Rotary
switch temperature, the
compressor is not allowed to
operate, but auxiliary heat is
allowed to operate.
2) When the outdoor
temperature is ≥S3 Rotary
switch temperature +35.6°F
(2°C), the compressor can be
operated but auxiliary heat
cannot be operated.
9
Rotary
Switch
S3
1,2
Set outdoor temperature
limitation (for auxiliary
heating or compressor)
Table A
background
mrcool.com 40
No.
Dial
Code
Control
Scenario
Function ON OFF Note
10 SW3-1 1
Maximum continuous
runtime allowed before
system automatically stages
up capacity to satisfy set
point. This adds 1 to 5°F
to the user set point to
increase capacity and satisfy
user set point.
30 minutes [Default] 90 minutes
11 SW3-2 1
Cooling and heating Y/Y2
temperature dierential
adjustment
Compressor slower speed [Default] Faster compressor
Only aects
compressor
12 SW3-3 1
Compressor running
(demand working with heat
pump+electric heat)
Compressor slower speed [Default] Faster compressor
Only aects
compressor
and W2
13 SW3-3 2
Temperature dierential
to activate second stage
auxiliary heating (the
GAP of T1 and Ts). Wire
controller demand with heat
pump+electric heat working
together
4°F (2°C) [Default] 6°F (3°C)
14 SW3-4 1, 3
Fan speed of cooling mode
when 24V Thermostat is
applied for
Turbo High
15
SW4-1
SW4-2
SW4-3
1, 2, 3
Electric heat nominal CFM
adjustment
Available settings are 000/001/010/011. Each digit corresponds
to an individual switch position. For example [SW4-1 OFF, SW4-2
ON, SW4-3 OFF] = 010; See table 11 for the corresponding CFM
adjustment.
16 SW4-4 2
Temperature dierential to
activate third stage auxiliary
heating (the GAP of T1 and
Ts) Wire controller demand
with heat pump + electric
heat working together
6°F (3°C) [Default] 8° (4°C)
Only valid
for product
which has
three stage
auxiliary
heating.
17 SW4-4 1,3 Default ON
[Default] For single stage
supplemental heat, W1 and W2
are connected
For dual stage supplemental
heat, W1 and W2 are
controlled independently
18 S4-2 1,3 DH Function Selection
[Default] Dehumidication
control not available
Dehumidication feature is
enabled through thermostat
19 SW5-3 1,2,3 L or Alarm relay selection
L output 24V or alarm relay
close only when refrigerant
sensor fault or R454B
refrigerant leakage is detected
[Default] L output 24V or alarm
relay closed when any fault is
detected
20 SW5-4 1,2,3 R output selection
R stop output 24V when
refrigerant sensor fault or
R454B refrigerant leakage is
detected
[Default] R keep output 24V
even when refrigerant sensor
fault or R454B refrigerant
leakage is detected
ELECTRICAL CONNECTIONS
7
background
mrcool.com41
Address DIP Switch:
Address dialing S1+SW8: When the user uses the
centralized controller, the address dialing is required.
Network address: The address silkscreen is NET
address, which is composed of a 16-bit address rotary
code S1 plus a two-digit DIP switch SW8 [Set during
engineering installation, network function does not
need to be set]
When SW8 is 00 (the dialing code is not connected), the
network address value is the value of S1;
When SW8 is 10 (corresponding to the switch of the
hardware connected to the 10K resistor), the network
address value is S1 plus 16;
Determined by dial code SW8 1-10K 2-5.1K.
When SW8 is 01 (corresponding to the dial code of the
5.1K resistor connected to the hardware is turned on),
the network address value is the value of S1 plus 32;
When SW8 is 11 (all dialing codes are on), the network
address value is the value of S1 plus 48.
ELECTRICAL CONNECTIONS
7
Outdoor Unit DIP Switch Setting:
No. Dial Code Features ON OFF
1 SW1-1 Function to be dened
2 SW1-2 Communication dial code 24V communication only
24V communication/ 485
communication
3 SW1-3 Strong cold and strong heat function
The cooling/heating target pressure
compensation value is valid
The cooling/heating target pressure
compensation value is invalid
4 SW1-4 Enhanced defrosting function Enhanced defrosting
Default setting (standard defrost
algorithm)
Press the SW4 button for 10 seconds for
force defrosting.
S3 S3 (°F) S3 (°C)
0 OFF OFF
1 -22 -30
2 -18 -28
3 -15 -26
4 -11 -24
5 -8 -22
6 -4 -20
7 3 -16
8 10 -12
9 18 -8
A 25 -4
B 32 0
C 36 2
D 39 4
E 43 6
F 46 8
Determined by dial code SW8 1-10K 2-5.1K
Dial Code Selection Website Address
S1 + 48
S1 + 32
S1 + 16
S1
background
mrcool.com 42
Air Volume Table
ELECTRICAL CONNECTIONS
7
Capacity
External Static
Pressure Range
Fan Speed
Electric
Auxiliary Heat
Module
24V Thermostat Wired Controller
Airow
Volume
(CFM)
DIP Switch
24V Terminal
Engaged
DIP Switch Mode
24K
(2 Ton)
0-1.0in. wc.
Cooling Turbo - SW3-4 = ON Y2/Y - Cool 824
Cooling High - SW3-4 = OFF Y2/Y - Cool 759
Cooling Medium - - Y1 - Cool 694
Cooling Low - - - - Cool 629
Heat Pump Turbo - - - - Heat 788
Heat Pump High - - B + Y2/Y, W - Heat 753
Heat Pump Medium - - Y1 - Heat 641
Heat Pump Low - - - - Heat 524
Electric Auxiliary
Module 0 [Default]
15kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 988
Electric Auxiliary
Module 1
15kW, 10kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
Heat + AUX, AUX 841
Electric Auxiliary
Module 2
10kW, 8kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
Heat + AUX, AUX 818
Electric Auxiliary
Module 3
5kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
Heat + AUX, AUX 788
30K
(2.5 Ton)
0-1.0 in. wc.
Cooling Turbo - SW3-4 = ON Y2/Y - Cool 988
Cooling High - SW3-4 = OFF Y2/Y - Cool 894
Cooling Medium - -
Y1 - Cool 806
Cooling Low - - - - Cool 712
Heat Pump Turbo - - - - Heat 988
Heat Pump High - - B+Y2/Y, W - Heat 894
Heat Pump Medium - - Y1 - Heat 806
Heat Pump Low - - - - Heat 712
Electric Auxiliary
Heat Module 0
15kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 1088
Electric Auxiliary
Heat Module 1
15kW, 10kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
Heat + AUX, AUX 1029
Electric Auxiliary
Heat Module 2
10kW, 8kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
Heat + AUX, AUX 976
Electric Auxiliary
Heat Module 3
5kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
W1. W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
Heat + AUX, AUX 918
The constant airow volume motor is applied. Therefore, the airow volume is constant at all ESP within the stated range.
background
mrcool.com43
ELECTRICAL CONNECTIONS
7
Capacity
External Static
Pressure Range
Fan Speed
Electric
Auxiliary Heat
Module
24V Thermostat
Wired Controller
Airow
Volume
(CFM)
DIP Switch
24V Terminal
Engaged
DIP Switch Mode
36K
(3 Ton)
0-1.0 in. wc.
Cooling Turbo -
SW3-4 = ON
Y2/Y - Cool 1188
Cooling High -
SW3-4 = OFF
Y2/Y - Cool 1082
Cooling Medium -
-
Y1 - Cool 971
Cooling Low -
-
- - Cool 865
Heat Pump Turbo -
-
- - Heat 1112
Heat Pump High -
-
B + Y2/Y, W - Heat 1059
Heat Pump Medium -
-
Y1 - Heat 794
Heat Pump Low -
-
- - Heat 582
Electric Auxiliary
Module 0 [Default]
20kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 1306
Electric Auxiliary
Module 1
15kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
Heat + AUX, AUX 1241
Electric Auxiliary
Module 2
10kW, 8kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
Heat + AUX, AUX 1176
Electric Auxiliary
Module 3
5kW, 8kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
Heat + AUX, AUX 1112
48K
(4 Ton)
0-0.8 in.wc.
Cooling Turbo -
SW3-4 = ON
Y2/Y
-
Cool 1600
Cooling High -
SW3-4 = OFF
Y2/Y
-
Cool 1441
Cooling Medium -
-
Y1
-
Cool 1265
Cooling Low -
-
-
-
Cool 1088
Heat Pump Turbo -
-
-
-
Heat 1471
Heat Pump High -
-
B+Y2/Y, W
-
Heat 1324
Heat Pump Medium -
-
Y1
-
Heat 1147
Heat Pump Low -
-
-
-
Heat 971
Electric Auxiliary Heat
Module 0
20kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 1741
Electric Auxiliary Heat
Module 1
15kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
Heat + AUX, AUX 1653
Electric Auxiliary Heat
Module 2
10kW, 8kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
Heat + AUX, AUX 1559
Electric Auxiliary Heat
Module 3
8kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
Heat + AUX, AUX 1471
60K
(5 Ton)
0-0.8 in.wc.
Cooling Turbo -
SW3-4 = ON
Y2/Y
-
Cool 1800
Cooling High -
SW3-4 = OFF
Y2/Y
-
Cool 1647
Cooling Medium -
-
Y1
-
Cool 1500
Cooling Low -
-
-
-
Cool 1234
Heat Pump Turbo -
-
-
-
Heat 1682
Heat Pump High -
-
B+Y2/Y, W
-
Heat 1582
Heat Pump Medium -
-
Y1
-
Heat 1359
Heat Pump Low -
-
-
-
Heat 1047
Electric Auxiliary Heat
Module 0
25kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 2171
Electric Auxiliary Heat
Module 1
15kW, 20kW
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 2029
Electric Auxiliary Heat
Module 2
10kW, 15kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = OFF
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 1894
Electric Auxiliary Heat
Module 3
10kW
SW4-1 = OFF
SW4-2 = ON
SW4-3 = ON
W1, W2, AUX
SW4-1 = OFF
SW4-2 = OFF
SW4-3 = OFF
Heat + AUX, AUX 1753
background
mrcool.com 44
AIR EVACUATION
8
8.1 Preparation & Precautions
NOTE: When opening valve stems, turn the hexagonal wrench until it hits against the stopper. Do not try to
force the valve open further.
Air and foreign matter in the refrigerant circuit can cause abnormal rises in pressure, which can damage the
unit, reduce its eciency, and cause injury. Use a vacuum pump and manifold gauge to evacuate the refrigerant
circuit, removing any non-condensible gas and moisture from the system. Evacuation should be performed
upon initial installation and when unit is relocated.
Before Performing Evacuation:
; Check to ensure the connective pipes between the indoor and outdoor units are connected properly.
; Check to make sure all wiring is connected properly.
1. Connect the charge hose of the manifold gauge to service port on the outdoor unit’s low pressure valve.
2. Connect another charge hose from the manifold gauge to the vacuum pump.
3. Open the low pressure side of the manifold gauge. Keep the high pressure side closed.
4. Turn on the vacuum pump to evacuate the system.
5. Run the vacuum for at least 15 minutes, or until the compound meter reads -500 Microns (-10
5
Pa).
6. Close the low pressure side of the manifold gauge, and turn o the vacuum pump.
7. Wait for 5 minutes, then check that there has been no change in system pressure.
8. If there is a change in system pressure, refer to the Gas Leak Check section for information on how to check
for leaks. If there is no change in system pressure, unscrew the cap from the packed valve (high pressure
valve).
9. Insert hexagonal wrench into the packed valve (high pressure valve) and open the valve by turning the
wrench in a 1/4 counter clockwise turn. Listen for gas to exit the system, then close the valve after 5 seconds.
10. Watch the pressure gauge for one minute to make sure that there is no change in pressure. The pressure
gauge should read slightly higher than atmospheric pressure.
11. Remove the charge hose from the service port.
Outdoor Unit
12. Open the stop valves of the outdoor unit to start the ow of the refrigerant between the indoor and outdoor
unit. Using a hexagonal wrench, fully open both the high pressure and low pressure valves.
13. Tighten valve caps on all three valves (service port, high pressure, low pressure) by hand. You may tighten it
further using a torque wrench if needed.
8.2 Evacuation Instructions
background
mrcool.com45
TEST RUN
9
CAUTION
Failure to perform the test run may result in unit damage, property damage, or personal injury.
A test run must be performed after the entire system has been completely installed. Conrm the following
points before performing the test:
a. Indoor and outdoor units are properly installed.
b. Piping and wiring are properly connected.
c. No obstacles near the inlet and outlet of the unit that might cause poor performance or product
malfunction.
d. Refrigeration system does not leak.
e. Drainage system is unimpeded and draining to a safe location.
f. Insulation of piping and duct is properly installed.
g. Grounding wires are properly connected.
h. Length of the piping and additional refrigerant capacity have been recorded.
i. Power voltage is the correct voltage for the system.
1. Open both the liquid and gas service valves.
2. Turn on the main power switch and allow the unit to warm up.
3. Set the unit to COOL mode.
9.1 Before Test Run
9.2 Test Run Instructions
6. Drainage Test
; Ensure the drainpipe ows smoothly. New buildings should perform this test before nishing the ceiling.
; Turn on the main power switch and run the unit in COOL mode.
; Check to see that the water is discharged. It may take up to one minute before the unit begins to drain
depending on the drainpipe.
; Make sure that there are no leaks in any of the piping.
; Stop the unit. Turn o the main power switch and reinstall the test cover.
4. For the Indoor Unit
; Double check to see if the room temperature is
being registered correctly.
; Ensure the manual buttons on the indoor unit
work properly.
; Check to see that the drainage system is
unimpeded and draining smoothly.
; Ensure there is no vibration or abnormal noise
during operation.
5. For the Outdoor Unit
; Check for any leaks from the refrigeration system.
; Make sure there is no vibration or abnormal noise
during operation.
; Ensure the wind, noise, and water generated by
the unit do not disturb others or pose a safety
hazard.
background
mrcool.com 46
POST-INSTALLATION
10
NOTE: If the unit malfunctions or does not
operate according to expectations, refer to
the Troubleshooting section of the Service
Manual before calling customer service.
10.1 Care & Maintenance
BEFORE CLEANING & MAINTENANCE
• Disconnect the power before cleaning or maintenance, except for cleaning the air lter.
• Contact an authorized service technician for repair or maintenance. Improper repair and maintenance may
cause water leakage, electrical shock, or re, and may void your warranty.
• Do not substitute a blown fuse with a higher or lower amperage rating fuse, as this may cause circuit damage or
an electrical re. The replacement fuse must be identical to the one removed.
• Make sure the drain hose is set up according to the instructions. Failure to do so could cause leakage and result
in personal property damage, re, and electric shock.
• Make sure that all wires are connected properly. Failure to connect wires according to instructions can result in
electrical shock or re.
• Only use a soft, dry cloth to wipe the unit clean. If needed, use a cloth soaked in warm water to wipe it clean.
• Do not use chemicals or chemically treated cloths to clean the unit.
• Do not use benzene, paint thinner, polishing powder, or other solvents to clean the unit. They can cause the
plastic surface to crack or deform.
• To avoid panel deformation or discoloration, do not use water hotter than 104°F (40°C) to clean the front panel.
• Do not wash the unit under running water. Doing so creates an electrical hazard.
• Clean the unit using a damp, lint-free cloth and neutral detergent. Dry the unit with a dry, lint-free cloth.
• Do not use water to clean the inside of the indoor unit. This can destroy insulation and cause electrical shock.
• An authorized dealer or licensed service provider should perform maintenance and cleaning of the outdoor unit.
• Any unit repairs should be performed by an authorized dealer or a licensed service provider.
CHANGING THE FILTER
• Before changing the lter or cleaning, turn o the unit and disconnect its power supply.
• When removing the lter, do not touch the metal parts in the unit. The sharp metal edges can cut you.
• Do not expose the lter to direct sunlight when drying. This can shrink the lter.
Maintaining the Unit
Long Periods of Non-Use
If you plan not to use the unit for an extended
period of time, do the following:
Clean all lters.
Turn on fan function
until unit dries out
completely.
Pre-Season Inspection
After long periods of non-use, or before periods of frequent use,
do the following:
Clean all lters.
Check for damaged
wires.
Check for leaks.
Ensure nothing is blocking the air inlets & outlets.
background
mrcool.com47
CAUTION
If any of the following conditions occur, turn o the unit immediately.
• You smell a burning odor.
• The unit emits loud or abnormal sounds.
• A power fuse blows or the circuit breaker frequently trips.
• Water or other objects fall into or out of the unit.
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORIZED SERVICE PROVIDER IMMEDIATELY.
10.2 Troubleshooting
The following problems are not a malfunction, and in most situations will not require repairs.
Issue Possible Causes
Unit does not turn on when
pressingON/OFFbutton.
The unit has a 3-minute protection feature that prevents the unit from overloading.
The unit cannot be restarted within 3 minutes of being turned o.
If the operation light and PRE-DEF indicators are lit up, the outdoor temperature is
too cold and the unit's anti-cold wind is activated in order to defrost the unit.
TheunitchangesfromCOOL/
HEAT mode to FAN mode.
The unit may change its setting to prevent frost from forming on the unit. Once the
temperature increases, the unit will start operating in the previously selected mode
again.
The set temperature has been reached, at which point the unit turns o the
compressor. The unit will continue operating when the temperature uctuates again.
The indoor unit emits white
mist.
In humid regions, a large temperature dierence between the room's air and the
conditioned air can cause white mist.
Both the indoor and outdoor
units emit white mist.
When the unit restarts in heat mode after defrosting, white mist may be emitted due
to moisture generated from the defrosting process.
The indoor unit makes noises.
A squeaking sound is heard when the system is o or in cool mode. The noise is also
heard when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in heat mode due to expansion
and contraction of the unit's plastic parts.
Both the indoor unit and the
outdoor unit make noises.
Low hissing sound during operation: this is normal and is caused by refrigerant gas
owing through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting:
this noise is normal and is caused by the refrigerant gas stopping or changing
direction.
Squeaking sound: normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises. The unit will make dierent sounds based on its current operating mode.
Dust is emitted from either the
indoor or outdoor unit.
The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit during
long periods of inactivity.
The unit emits a bad odor.
The unit may absorb odors from the environment (such as furniture, cooking,
cigarettes, etc.) which will be emitted during operation.
The unit's lters have become moldy and should be cleaned.
The fan of the outdoor unit
does not operate.
During operation, the fan speed is controlled to optimize product operation.
POST-INSTALLATION
10
Common Issues
Note: If a problem persists, contact a local dealer or MRCOOL
®
customer service. Provide them with a detailed description of
the unit malfunction as well as your model number.
background
mrcool.com 48
POST-INSTALLATION
10
Problem Possible Causes Solution
Poor Cooling
Performance
Temperature setting may be higher
than ambient room temperature.
Lower the temperature setting.
The heat exchanger on the indoor or
outdoor unit is dirty.
Clean the aected heat exchanger.
Theairlterisdirty. Remove the lter and clean it according to instructions.
The air inlet or outlet of either unit is
blocked.
Turn the unit o, remove the obstruction and turn it back
on.
Doors and windows are open.
Make sure that all doors and windows are closed while
operating the unit.
Excessive heat is generated by
sunlight.
Close windows and curtains during periods of high heat
or bright sunshine.
Too many sources of heat in the room
(people, computers, electronics, etc.)
Reduce the amount of heat sources.
Low refrigerant due to leak or long-
term use.
Check for leaks, re-seal if necessary, and top o
refrigerant.
The unit is not
working
Power failure Wait for the power to be restored.
Thepoweristurnedo. Turn on the power.
The fuse is burned out. Replace the fuse.
The unit's 3-minute protection has
been activated.
Wait three minutes after restarting the unit.
Timer is activated Turn timer o
The unit starts and
stops frequently.
There's too much or too little
refrigerant in the system.
Call a technician to check for leaks and recharge the
system with refrigerant.
Incompressible gas, air, or moisture,
or foreign material has entered the
system.
Call a technician to evacuate and recharge the system
with refrigerant.
System circuit is blocked.
Determine which circuit is blocked and replace the
malfunctioning piece of equipment.
The compressor is broken. Call a technician to replace the compressor.
The voltage is too high or too low. Install a manostat to regulate the voltage.
Poor heating
performance
The outdoor temperature is
extremely low
Use auxiliary heating device
Cold air is entering through doors and
windows.
Make sure that all doors and windows are closed during
use.
Low refrigerant due to leak or long-
term use.
Call a technician to check for leaks, re-seal if necessary,
and top o refrigerant.
When trouble occurs, please check the following points before contacting a repair company.
Note: If your problem persists after performing the checks and diagnostics above, turn o your unit immediately and contact
a local dealer or MRCOOL
®
customer service.
background
mrcool.com49
Note:
1: 24V signal
0: No 24V signal
*: 1 or 0
The AUU will turn o if the 24V input cannot meet the table.
10.3 24V Signal Chart
Mode Priority G Y1 Y/Y2 B W W1 W2 E/AUX DH Fan Speed Display
OFF / 0 0 0 0 0 0 0 0 * OFF 00
FAN 7 1 0 0 * 0 0 0 0 * Low 01
Cooling Stage 1
6
* 1 0 0 0 0 0 0 1 Mid 02
Cooling Stage 2 * * 1 0 0 0 0 0 1 High 03
Dehumidication 1 * 1 0 0 0 0 0 0 0 Low 04
Dehumidication 2 * * 1 0 0 0 0 0 0 Low 05
Heat Pump Stage 1
5
* 1 0 1 0 0 0 0 1 Mid 06
Heat Pump Stage 2 * * 1 1 0 0 0 0 1 High
07
Heat Pump Stage 2 * * * * 1 0 0 0 1 High
Electric Auxiliary Heat
Module 1
3
* 0 0 * 0 1 0
0 * Turbo
08
Electric Auxiliary Heat
Module 2
* 0 0 * 0 0 1 0 * Turbo
Electric Auxiliary Heat
Module 1 & 2
* 0 0 * 0 1 1 0 * Turbo 09
Heat Pump Stage 1 +
Electric Auxiliary Heat
Module 1
4
* 1 0 1 0 1 0 0 1 Turbo
10
Heat Pump Stage 1 +
Electric Auxiliary Heat
Module 2
* 1 0 1 0 0 1 0 1 Turbo
Heat Pump Stage 2 +
Electric Auxiliary Heat
Module 1
* * 1 1 0 1 0 0 1 Turbo
Heat Pump Stage 2 +
Electric Auxiliary Heat
Module 1
* * * * 1 1 0 0 1 Turbo
Heat Pump Stage 2 +
Electric Auxiliary Heat
Module 2
* * 1 1 0 0 1 0 1 Turbo
Heat Pump Stage 2 +
Electric Auxiliary Heat
Module 2
* * * * 1 0 1 0 1 Turbo
Heat Pump Stage 1 +
Electric Auxiliary Heat
Module 1 & 2
* 1 0 1 0 1 1 0 1 Turbo
11
Heat Pump Stage 2 +
Electric Auxiliary Heat
Module 1 & 2
* * 1 1 0 1 1 0
1 Turbo
Heat Pump Stage 2 +
Electric Auxiliary Heat
Module 1 & 2
* * * * 1 1 1 0 1 Turbo
Emergency Heat 1 * * * * * * * 1 * Turbo 12
Heating Zone Control
2
* 1 0 1 0 * * 0 0 Low
13Heating Zone Control * * 1 1 0 * * 0 0 Low
Heating Zone Control * * * * 1 * * 0 0 Low
POST-INSTALLATION
10
background
mrcool.com 50
POST-INSTALLATION
10
10.4 Error Display (Indoor Unit)
When the indoor unit encounters a recognized error, the operation lamp will ash in a corresponding series, the
timer lamp may turn on or begin ashing, and an error code will be displayed. These error codes are described
in the following table:
Display Error Information Solution
EC 07 ODU fan speed out of control TS21
EC 0D ODU malfunction TS38
EC 51 ODU EEPROM parameter error TS19
EC 52 ODU coil temp. sensor (T3) error TS23
EC 53 ODU ambient temp. sensor (T4) error TS23
EC 54 COMP. discharge temp. sensor (TP) error TS23
EC 56 IDU coil outlet temp. sensor (T2B) error (Multi-Zone) TS23
EC C1 Other IDU refrigerant sensor detects leakage (Multi-Zone) TS35
EH 00 IDU EEPROM malfunction TS19
EH 03 IDU fan speed out of control TS21
EH 0A IDU EEPROM parameter error TS19
EH 0B IDU main control board & display board communication error TS39
EH 0E Water-level alarm malfunction TS25
EH 3A External fan DC bus voltage is too low TS35
EH 3B External fan DC bus voltage is too high TS35
EH 60 IDU room temp. sensor (T1) error TS23
EH 61 IDU coil temp. sensor (T2) error TS23
EH 62 / EH 66 Evaporator coil inlet temperature sensor T2B is in open circuit or short circuit TS23
EH 65 Evaporator coil temperature sensor T2A is in open circuit or short circuit TS23
EH BA Communication malfunction between indoor unit and external fan module TS35
EH C1 Refrigerant sensor detects leakage TS37
EH C2 Refrigerant sensor is out of range and leakage is detected TS37
EH C3 Refrigerant sensor is out of range TS36
EL 01 IDU & ODU communication error TS20
EL 0C System lacks refrigerant TS23
EL 16 Communication malfunction between adapter board and outdoor main board TS40
FH CC Refrigerant sensor error TS36
FL 09 Mismatch between the new and old platforms TS40
pC 00 ODU IPM module protection TS26
PC 01 ODU voltage protection TS27
PC 02 Compressor top (or IPM) temp. protection TS32
PC 03 Pressure protection (low or high pressure) TS29
PC 04 Inverter compressor drive error TS28
PC 0l Low ambient temperature protection TS33
---- IDUs mode conict (Multi-Zone) --
For other errors:
The display board may show a
garbled code or a code undened
by the service manual. Ensure that
this code is not a temperature
reading.
Troubleshooting:
Test the unit using the remote control. If
the unit does not resoond to the remote,
the indoor PCB requires replacement. If the
unit responds, the display board requires
replacement.
LED Flash Frequency:
background
mrcool.com51
10.6 Error Display (Outdoor Unit)
Display Error Information Solution
DF Defrosting
Normal display, not error
code
FC Forced cooling
EC 07 ODU fan speed out of control TS12
EC 51 ODU EEPROM parameter error TS10
EC 52 ODU coil temperature sensor (T3) error TS14
EC 53 ODU ambient temperature sensor (T4) error TS14
EC 54 Compressor discharge temperature sensor (T4) error TS14
EC 55 ODU IPM module temperature sensor malfunction TS33
EC 57 Refrigerant pipe temperature sensor error TS14
EC SC Pressure sensor failure TS35
EL 01 IDU & ODU communication error TS11
EL 16 Communication malfunction between adapter board and ODU main board TS36
PC 00 IPM Module Protection TS17
PC 02 Compressor top (or IPM) temperature protection / Refrigerant sensor error TS25
PC 06 Discharge temperature protection of compressor TS23
PC 08 Outdoor overcurrent protection TS15
PC 0A High temperature protection of condenser TS24
PC 0F PFC Module Protection TS22
PC 10 ODU low AC voltage protection TS19
PC 11 ODU main control board DC bus high voltage protection TS19
PC 12 ODU main control board DC bus low voltage protection / 341 MCE error TS19
PC 30 System high pressure protection TS27
PC 31 System low pressure protection TS29
PC 31 System low pressure protection TS29
PC 40 Communication error between ODU main chip and compressor driven chip TS21
PC 31 System low pressure protection TS29
PC 40 Communication error between ODU main chip and compressor driven chip TS21
PC 41 Compressor current sampling failure TS32
PC 42 Compressor start failure of outdoor unit TS15
PC 43 ODU compressor lack phase protection TS31
PC 44 ODU zero speed protection TS15
PC 45 ODU IR chip drive failure TS32
PC 46 Compressor speed out of control TS15
PC 49 Compressor overcurrent failure TS15
LC 06 High temperature protection of Inverter Module (IPM) TS26
PH 90 High temperature protection of evaporator TS34
PH 91 Low temperature protection of evaporator TS35
10.5 Error Display (Wired Controller)
Display Error Information Solution
EH B3 Communication malfunction between wire and master control TS34
The other error codes displayed on the wired controller are the same as those on the unit.
POST-INSTALLATION
10
background
mrcool.com 52
10.7 Quick Maintenance by Error Code
If you do not have the time to test which specic parts are faulty, you can change the required parts according to
the error code. You can nd the parts to replace by error code in the following table.
Part Requiring
Replacement
Error Code
EH 00/EH 0A EL 01 EH 03 EH 60 EH 61 EH 62/EH66 EH 65 EL OC
EH C1/CH
C2
EH oE EH OB
Indoor PCB √ √ √ √ √ √ √ √ X √ √
Outdoor PCB X √ X X X X X X X X X
Indoor Fan Motor X X √ X X X X X X X X
T1 Sensor X X X √ X X X X X X X
T2 Sensor X X X X √ X X √ X √ X
T2B Sensor X X X X X √ X X X X X
T2A Sensor X X X X X X √ X X X X
Magnet Ring X √ X X X X X X X X X
Compressor X X X X X X X X X X X
Additional Refrigerant X X X X X X X √ √
√ X
Water-Level Switch X X X X X X X X X √ X
Water Pump X X X X X X X X X √ X
Display Board X X X X X X X X X X √
Part Requiring
Replacement
Error Code
EC 54 EC 51 EC 52 EC 53 EC 56 EC 07 PC 00 PC 01 PC 02 PC 04 PC 03 FH cc/EH C3
Indoor PCB X X X X X X X X X X X √
Outdoor PCB √ √ √ √ √ √ √ √ √ √ √ X
Outdoor Fan Motor X X X X X √ √ X √ √ X X
T3 Sensor X X √ X X X X X X X X X
T4 Sensor X X X √ X X X X X X X X
TP Sensor √ X X X X X X X X X X X
T2B Sensor X X X X √ X X X X X X X
Refrigerant Sensor X X X X X X X X X X X √
Reactor Sensor X X X X X X X √ X X X X
Compressor X
X X X X X √ X X √ X X
IPM Module Board X X X X X X √ √ √ √ X X
Pressure Protector X X X X X X X X X X √ X
Additional Refrigerant X X X X X X X X X X √ X
POST-INSTALLATION
10
Part Requiring Replacement
Error Code
EL 01 EC 51 EC 52 EC 53 EC 54 EC 55 EC SC EC 57
Indoor PCB √ X X X X X X X
Outdoor PCB √ √ √ √ √ √ √ √
ODU Coil Temp. Sensor X X √ X X X X X
ODU Ambient Temp. Sensor X X X √ X X X X
COMP. Discharge Temp. Sensor X X X X √ X X X
IPM Module Temperature Sensor X X X X X √ X X
Pressure Sensor X X X X X X √ X
Refrigerant Pipe Temperature Sensor X X X X X X X √
Condenser Temperature Sensor X X X X X X X X
Reactor √ X X X X X X X
IPM Module Board √ X X X X X X X
background
mrcool.com53
10.8 Outdoor Unit Point Check Function
• A check switch is included on the adapter board.
• Push SW4 to check the unit's status while running. The digital display shows the following codes each time
SW4 is pushed.
Number of
Presses
Display Remark
0 Normal Display
Displays running frequency, running state, or malfunction code
Defrosting mode: "dF" or alternative displays between running frequency and "dF" (each appears for 0.5s)
Forced cooling mode: the LED displays "FC" or alternative displays between running frequency and "FC"
(each appears for 0.5s)
1
Indoor unit capacity
demand code
Actual data *HP*10
If capacity demand code is higher than 99, the decimal point of the high digit tube will be
lighted. (For example, the digital display tube shows "5.0". 5.0 multiplied by 10 becomes 50,
then added to 100 to become 150. The actual capacity demand = 150/10=15. If the digital
display tube shows "60", the actual capacity demand = 60/10=6.0.)
GA algorithm models display "--"
2
The frequency
after the capacity
requirement adapter
If the value is higher than 99, the decimal point of the high digit tube will be lighted.
POST-INSTALLATION
10
Part Requiring Replacement
Error Code
EC 07 PC 00
PC 10 / PC 11 /
PC 12
PC 02
PC 08 / PC 42 / PC
44 / PC 46 / PC 49
PC 0f PC 41 PH 90 PH 91
Outdoor PCB √ √ √ √ √ √ √ X X
Outdoor Fan Motor √ √ X X X X X X X
Reactor or Inductance X √ √ X √ √ X X X
Compressor X √ X X X X X X X
IPM Module Board X √ √ X √ X X X X
Bridge Rectier X √ √ X √ X X X X
Evaporator Coil Temperature Sensor X X X X X X X √ √
PFC Module X X X X X √ X X X
Additional Refrigerant X X X X X X X X X
Overload Protector X X X √ X X X X X
ODU Ambient Temperature Sensor X X X X X X X X X
Refrigerant Pipe Temperature Sensor X X X X X X X X X
Indoor Fan
X X X X X X X √ X
Indoor PCB X X X X X X X √ √
Part Requiring Replacement
Error Code
PC 40 PC 43 PC 45 PC 06 PC oA PC 30 PC 31 EL 16
Outdoor PCB √ √ X √ √ √ √ √
Outdoor Fan Motor X X X X √ √ √ X
ODU Coil Temp. Sensor X X X X √ X X X
Comp. Discharge Temp. Sensor X X X √ X X X X
Compressor X √ X X X X X X
IPM Module Board X X √ X X X X X
Additional Refrigerant X X X √ √ X √ X
Electric Control Box √ X X X X X X X
High Pressure Switch X X X X X √ X X
Low Pressure Switch X X X X X X √ X
Adapter Board X X X X X X X √
background
mrcool.com 54
Number
of
Presses
Display Remark
3 Room Temperature (T1)
If the temperature is lower than 0°C (32°F), the digital display tube will show "0".
If the temperature is higher than 70°C (158°F), the digital display tube will show "70".
4
Indoor Unit Evaporator
Temperature (T2)
If the temperature is lower an -9°C (15.8°F), the digital display tube will show "-9". If the
temperature is higher than 70°C (158°F), the digital display tube will show "70". If the
outdoor unit is not connected, the digital display tube will show "--".
5 Condenser pipe temperature (T3)
6
Outdoor ambient temperature
(T4)
7
Compressor discharge
temperature (TP)
The display value is between 0~199°C (32°F~390.2°F). If the temperature is lower than
0°C (32°F), the digital display tube will show "0". If the temperature is higher than 99°C
(210.2°F), the decimal point of the high digit tube will be lighted. (For example, the
digital display tube shows "0.5", so 0.5 multiplied by 10 becomes 5, then added to 100
to become 105°C (221°F).)
8 AD value of current
The display value is a hex number.
For example, the digital display tube shows "Cd", so
C*16
1
+d*16
0
=12*16+13=205 means AD value is 205.
9 AD value of voltage
10 Indoor unit Running Mode Code
Standby: 0, Cooling: 1, Heating: 2, Fan Only: 3, Drying: 4, Forced Cooling: 6, Defrost: 7,
ECO: 9, Forced Defrosting: A, Self-Clean: B
11
Outdoor Unit Running Mode
Code
12 EXV Open Angle
Actual Data / 4
If the value is higher than 99, the decimal point of the high digit tube will be lighted. For
example, the digital display tube shows "2.0". 2.0 multiplied by 10 becomes 20, then
added to 100 to become 120. This means the EXV open angle is 120x4=480p.
13
Frequency Limit Symbol
AD value of current
AD value of voltage
Indoor unit Running Mode Code
Outdoor Unit Running Mode
Code
Bit 7 Frequenc limit caused by IGBT radiator
The display value is a hex
number. For example, the
digital display shows 2A. The
corresponding binary is 101010,
so Bit5=1, Bit3=1, and Bit1=1.
This means that a frequency
limit may be caused by T3 or
the current.
Bit 6 Reserved
Bit 5 Reserved
Bit 4
Frequency limit caused by low temperature of
T2. (LH00)
Bit 3 Frequency limit caused by T3. (LC01)
Bit 2 Frequency limit caused by TP. (LC02)
Bit 1 Frequency limit caused by current (LC03)
Bit 0 Frequency limit caused by voltage (LC05)
14 Outdoor unit fan speed
If it is higher than 99, the decimal point of the high digit tube will be lighted. (For
example, the digital display tube shows 2.0, so 2.0 multiplied by 10 becomes 20, then
added to 100 to become 120. This value is multiplied by 8, so the current fan speed:
120*8=960.
15
The average value of the
temperature values detected
by the high and low pressure
sensors in the last 10 seconds
of the compressor frequency
calculation period
The displayed value is the actual value plus 60. (When the displayed value is 10, the
actual value is -50.) When the displayed value is high than 99, the decimal point of
the high digit tube will be lighted. (For example, if it displays 2.0, 2.0 multiplied by 10
becomes 20, then added to 100 to become 120, so the actual value is 60.)
When there is no pressure sensor, it is displayed as --
16
The temperature value detected
by the high and low presure
sensor
17
AD value detected by the high
and low pressure sensor
The display value is a hex number. For example, the digital display tube shows "Cd".
C*16
1
+d*16
0
=12*16+13=205 means AD value is 205.
When there is no pressure sensor, it is displayed as --
18
The currently running
communication protocol version
00-99
POST-INSTALLATION
10
background
MRCOOL® UNIVERSAL
®
Series
The design and specications of this product and/or manual are subject to change without prior notice.
Consult with the sales agency or manufacturer for details.

Specifications