Printed in Thailand
GENERATOR
’Owner s Manual
H i
FMAH
英
PANTONE
186C
K
背幅4.6mm
EU1000i
See page 12 for Initial Use Instructions
2023 Honda Motor Co., Ltd. -All Rights Reserved
C
EU1000i
31Z40614
00X31-Z40-6140

Keep this owner’s manual handy so that you can refer to it any time.
This owner’s manual is considered a permanent part of the generator and
should remain with the generator if resold.
The information and specifications included in this publication were in effect at
the time of approval for printing. Honda Motor Co., Ltd. reserves the right,
however, to discontinue or change specifications or design at any time without
notice and without incurring any obligation whatsoever.
The illustration may vary according to the type.
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other
reproductive harm.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.

1
INTRODUCTION
Thank you for purchasing a Honda generator.
We would like to help you get the best results from your new generator and to
operate it safely. This manual contains the information on how to do that; please
read it carefully.
We suggest you read the "Distributor’s Limited Warranty" (see page 79) to fully
understand its coverage and your responsibilities of ownership.
When your generator needs scheduled maintenance, keep in mind that your
Honda servicing dealer is specially trained in servicing Honda generators and is
supported by the parts and service divisions of American Honda. Your Honda
servicing dealer is dedicated to your satisfaction and will be pleased to answer
your questions and concerns.

2
INTRODUCTION
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important.
We have provided important safety messages in this manual and on the
generator. This information alerts you to potential hazards that could hurt you
or others. Please read these messages carefully.
Of course, it is not practical or possible to warn you about all the hazards
associated with operating or maintaining a generator. You must use your own
good judgment.
You will find important safety information in a variety of forms:
• Safety Labels — on the generator.
• Instructions — how to use this generator correctly and safely.
• Safety Headings — such as IMPORTANT SAFETY INFORMATION.
• Safety Messages — preceded by a safety alert symbol and one of three
signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
This entire book is filled with important safety information - please read it
carefully.
DAMAGE PREVENTION MESSAGES
In addition to the above, you will find information preceded by a symbol.
That information is intended to help you avoid damage to your generator, other
property, or the environment.
You WILL be KILLED or SERIOUSLY HURT if you do
not follow instructions.
You CAN be KILLED or SERIOUSLY HURT if you do
not follow instructions.
You CAN be HURT if you do not follow instructions.

3
CONTENTS
INTRODUCTION ................................................................................................ 1
GENERATOR SAFETY ........................................................................................ 6
IMPORTANT SAFETY INFORMATION................................................................................6
Operator Responsibility...................................................................................................6
Carbon Monoxide Hazards.............................................................................................7
Electric Shock Hazards .....................................................................................................8
Fire and Burn Hazards ......................................................................................................8
Refuel With Care.................................................................................................................9
Vehicles and Transportation Hazards.........................................................................9
SAFETY LABEL LOCATIONS................................................................................................10
INITIAL USE INSTRUCTIONS........................................................................... 12
ENGINE OIL..............................................................................................................................12
ENGINE OIL RECOMMENDATIONS..................................................................................13
FUEL...........................................................................................................................................14
FUEL RECOMMENDATIONS...............................................................................................17
CONTROLS & FEATURES................................................................................. 18
COMPONENT & CONTROL LOCATIONS ........................................................................18
CONTROLS...............................................................................................................................20
Engine Switch....................................................................................................................20
Starter Grip.........................................................................................................................20
Fuel Filler Cap Vent Lever .............................................................................................21
Choke Lever .......................................................................................................................21
Eco Throttle
®
Switch........................................................................................................22
CO-MINDER (CO Shut-off System) .............................................................................23
Parallel Operation Outlets ............................................................................................25
FEATURES ................................................................................................................................26
Output Indicator ..............................................................................................................26
Overload Alarm (Indicator)...........................................................................................26
Oil Alert
®
/Check Indicator .............................................................................................27
Ground Terminal..............................................................................................................27
BEFORE OPERATION....................................................................................... 28
ARE YOU READY TO GET STARTED? ...............................................................................28
Knowledge .........................................................................................................................28
IS YOUR GENERATOR READY TO GO?............................................................................28
Check the Engine.............................................................................................................29
AC Appliance and Power Cord....................................................................................29
ENGINE OIL LEVEL CHECK ..................................................................................................30
AIR FILTER CHECK .................................................................................................................32
SAFE OPERATING PRECAUTIONS ....................................................................................33

4
CONTENTS
OPERATION ..................................................................................................... 34
STARTING THE ENGINE .......................................................................................................34
STOPPING THE ENGINE.......................................................................................................37
HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)
................................................................................................................................................39
AC OPERATION ......................................................................................................................40
AC Applications ................................................................................................................42
AC PARALLEL OPERATION.................................................................................................43
AC Parallel Operation Applications...........................................................................45
ECO THROTTLE
®
SYSTEM....................................................................................................48
STANDBY POWER..................................................................................................................49
Connections to a Building’s Electrical System.......................................................49
System Ground.................................................................................................................49
Special Requirements.....................................................................................................50
SERVICING YOUR GENERATOR ...................................................................... 51
THE IMPORTANCE OF MAINTENANCE...........................................................................51
MAINTENANCE SAFETY ......................................................................................................52
Safety Precautions...........................................................................................................52
MAINTENANCE SCHEDULE................................................................................................53
ENGINE OIL CHANGE ...........................................................................................................53
AIR CLEANER SERVICE .........................................................................................................55
Foam Air Filter Cleaning................................................................................................55
SPARK PLUG SERVICE ..........................................................................................................56
SPARK ARRESTER SERVICE .................................................................................................58
STORAGE ......................................................................................................... 60
STORAGE PREPARATION ....................................................................................................60
Cleaning ..............................................................................................................................60
Fuel .......................................................................................................................................60
Engine Oil ...........................................................................................................................63
Engine Cylinder ................................................................................................................63
STORAGE PRECAUTIONS....................................................................................................64
REMOVAL FROM STORAGE................................................................................................64
TRANSPORTING .............................................................................................. 65
TAKING CARE OF UNEXPECTED PROBLEMS ................................................. 66
ENGINE WILL NOT START ...................................................................................................66
ENGINE LACKS POWER........................................................................................................67
NO POWER AT THE AC RECEPTACLES ...........................................................................67
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR
FLASHING ...........................................................................................................................68

5
CONTENTS
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING....................................................................................................68
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING
THE ENGINE........................................................................................................................68
TECHNICAL INFORMATION............................................................................ 69
SERIAL NUMBER LOCATION..............................................................................................69
CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION.......................70
EMISSION CONTROL SYSTEM INFORMATION.............................................................71
Air Index ...................................................................................................................................73
SPECIFICATIONS....................................................................................................................74
WIRING DIAGRAM.................................................................................................................76
CONSUMER INFORMATION............................................................................ 77
DEALER LOCATOR INFORMATION..................................................................................77
Honda PUBLICATIONS.........................................................................................................77
CUSTOMER SERVICE INFORMATION ..............................................................................78
Distributor’s Limited Warranty.........................................................................................79
Emission Control System Warranty................................................................................84
REGISTRATION .......................................................................................................................89
Please Register Your Generator..................................................................................89
INDEX.............................................................................................................. 90
QUICK REFERENCE INFORMATION.......................................inside back cover

6
GENERATOR SAFETY
IMPORTANT SAFETY INFORMATION
Honda generators are designed for use with electrical equipment that has
suitable power requirements. Other uses can result in injury to the operator or
damage to the generator and other property.
Most injuries or property damage can be prevented if you follow all instructions
in this manual and on the generator. The most common hazards are discussed
below, along with the best way to protect yourself and others.
Operator Responsibility
• Never attempt to modify the generator. It can cause an accident as well as
damage to the generator and appliances.
• Know how to stop the generator quickly in case of emergency.
• Understand the use of all generator controls, output receptacles, and
connections.
• Be sure that anyone who operates the generator receives proper instruction.
• Protect children by keeping them at a safe distance from the generator.
• Obey all applicable laws and regulations where the generator is used.

GENERATOR SAFETY
7
Carbon Monoxide Hazards
A generator's exhaust contains toxic carbon monoxide, which you cannot see or
smell. Breathing carbon monoxide can KILL YOU IN MINUTES. To avoid carbon
monoxide poisoning, follow these instructions when operating a generator:
• Only run a generator OUTSIDE, far away from windows, doors, and vents with
engine exhaust directed away from occupied structures.
• Never operate a generator inside a house, garage, basement, crawl space, any
type of vehicle, trailer, or boat, or any enclosed or partly enclosed space.
• Never operate a generator near open doors, windows, vents, or hatches.
• Get fresh air and seek medical attention immediately if you suspect you have
inhaled carbon monoxide.
Early symptoms of carbon monoxide exposure include headache, fatigue,
shortness of breath, nausea, and dizziness. Continued exposure to carbon
monoxide can cause loss of muscular coordination, loss of consciousness, and
then death.
To alert you to potentially dangerous levels of carbon monoxide coming from a
generator operating outside or from other sources, install battery operated
carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-
up on every level of your home, outside sleeping areas, inside any type of
vehicle, trailer, or boat in accordance with the alarm’s instructions.
CO-MINDER:
This generator is equipped with a CO-MINDER system that automatically stops
the engine before the surrounding carbon monoxide concentration exceeds a
certain concentration.
• Do not modify the CO-MINDER.
• The CO-MINDER cannot prevent all danger associated with or caused by
carbon monoxide. Pay careful attention to the location of the generator (see
page 23).

GENERATOR SAFETY
8
Electric Shock Hazards
The generator produces enough electric power to cause a serious shock or
electrocution if misused.
• Do not use in wet conditions. Keep the generator dry.
– Do not use in the rain or snow.
– Do not use near pool or a sprinkler system.
– Do not use when your hands are wet.
• If the generator is stored outdoors, unprotected from the weather, check all
of the electrical components on the control panel before each use. Moisture
or ice can cause a malfunction or short circuit in electrical components that
could result in electrocution.
• Do not connect to a building’s electrical system unless an isolation switch has
been installed by a qualified electrician.
• For parallel operation, use only a Honda approved parallel cable (optional
equipment) when connecting one EU1000i to another EU1000i generator.
• Never connect different generator models.
Fire and Burn Hazards
• The exhaust system gets hot enough to ignite some materials.
– Keep the generator at least 3 feet (1 meter) away from buildings and any
type of vehicle, trailer, boat, or other equipment during operation.
– Do not enclose the generator in any structure.
– Keep flammable materials away from the generator.
– Generators with standard equipment transport wheels must not be
operated with the wheels and/or stands removed.
– Do not block intake or exhaust vents, hoses, ports, or restrict air into or
away from generator.
– Do not add, remove, or modify covers, panels, cowlings, or straps.
• The muffler becomes very hot during operation and remains hot for a while
after stopping the engine. Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator.
• Do not pour the water directly on the generator to put out the fire when it
occurs. Use an appropriate fire extinguisher specially designed for electric fire
or oil fire.

GENERATOR SAFETY
9
Refuel With Care
Gasoline is highly flammable, and gasoline vapor can explode.
• Do not refuel during operation.
• Allow the engine to cool if it has been in operation.
• Refuel only outdoors in a well-ventilated area and on a level surface.
• Never smoke near gasoline, and keep other flames and sparks away.
• Do not overfill the fuel tank.
• Make sure that any spilled fuel has been wiped up and cleaned before
starting the engine.
• Always store gasoline in an approved container.
Vehicles and Transportation Hazards
• Do not operate the generator while it is being transported or while it is
mounted to any type vehicle, trailer, or boat.
• Do not operate the generator when it is in a storage, cargo, or security
enclosure, including any RV generator bay.
• Always completely remove the generator from the vehicle, RV, truck, trailer,
boat, other equipment or structure during operation.
• The generator must remain stationary while in operation.

GENERATOR SAFETY
10
SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious injury. Read
them carefully.
If a label comes off or becomes hard to read, contact your servicing dealer for a
replacement.

GENERATOR SAFETY
11

12
INITIAL USE INSTRUCTIONS
ENGINE OIL
The generator is shipped WITHOUT OIL in the engine.
1. Place the generator on a level surface.
2. Loosen the maintenance cover screw and remove the maintenance cover.
3. With the generator in a level position, remove the oil filler cap by turning it
counterclockwise.
4. Add enough oil to bring the oil level to the upper limit of the oil filler neck.
SAE10W-30 API service category SJ or later (or equivalent) is recommended
for general use; for additional recommendations (see page 13).
Maximum oil capacity: 8 oz (0.25 L)
Do not overfill the engine with oil. If the engine is overfilled, the excess oil
may be transferred to the air cleaner case and air filter.
5. Screw in the oil filler cap securely.
6. Reinstall the maintenance cover and tighten the maintenance cover screw
securely.
MAINTENANCE COVER SCREW
MAINTENANCE COVER
OIL FILLER CAP
UPPER LIMIT
(The oil exists to
the oil filler neck.)
OIL FILLER NECK
DIPSTICK

INITIAL USE INSTRUCTIONS
13
ENGINE OIL RECOMMENDATIONS
Oil is a major factor affecting performance and service life. Use 4-stroke
automotive detergent oil.
SAE 10W–30 is recommended for general use. Other viscosities shown in the
chart may be used when the average temperature in your area is within the
recommended range.
The SAE oil viscosity and service category are in the API label on the oil
container. Honda recommends that you use API service category SJ or later (or
equivalent) oil.
AMBIENT TEMPERATURE

INITIAL USE INSTRUCTIONS
14
FUEL
Add fuel to the generator in a well-ventilated area. Fuel only outdoors. Keep
gasoline away from appliance, such as pilot lights, barbecues, electric
appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes
environmental damage. Fuel carefully to avoid spilling fuel. Wipe up spills
immediately. Do not fill the fuel tank above the upper level mark (red) on the
fuel strainer. After fueling, reinstall the fuel tank cap securely.
When appropriate, with the engine stopped, check the fuel level. If the fuel level
is low, wait for the generator to cool off and refill the fuel tank.
This engine is certified to operate on unleaded gasoline with a pump octane
rating 86 or higher. Refer to "FUEL RECOMMENDATIONS" (see page 17) for
additional fuel recommendations.
Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel
tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited
Warranty.
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.

INITIAL USE INSTRUCTIONS
15
1. Remove the fuel filler cap.
2. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper
level mark (red) on the fuel strainer.
Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel
tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited
Warranty.
FUEL FILLER CAP
UPPER LIMIT MARK (RED)
FUEL STRAINER

INITIAL USE INSTRUCTIONS
16
3. After refueling, tighten the fuel filler cap securely. Keep the fuel filler cap vent
lever OFF for storage or transport, and ON to run the generator.
Move the generator at least 10 feet (3 meters) away from the fueling source and
site before starting the engine.
After initial fueling (or anytime the generator is run completely out of fuel),
starting the engine may require additional pulls of the starter grip. This
generator utilizes a vacuum operated fuel pump and may require additional
pulls to draw fuel into the carburetor.
FUEL FILLER CAP
OFF
ON
FUEL FILLER CAP VENT LEVER

INITIAL USE INSTRUCTIONS
17
FUEL RECOMMENDATIONS
This engine is certified to operate on regular unleaded gasoline with a pump
octane rating of 86 or higher.
Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting
dirt or water in the fuel tank.
You may use regular unleaded gasoline containing no more than 10% ethanol
(E10) or 5% methanol by volume. In addition, methanol must contain cosolvents
and corrosion inhibitors.
Use of fuels with content of ethanol or methanol greater than shown above may
cause starting and/or performance problems. It may also damage metal, rubber,
and plastic parts of the fuel system.
Engine damage or performance problems that result from using a fuel with
percentages of ethanol or methanol greater than shown above and leaded
gasoline are not covered under the Distributor Limited Warranty.
If your equipment will be used on an infrequent basis, refer to the fuel section of
"STORAGE" chapter (see page 60) for additional information regarding fuel
deterioration.

18
CONTROLS & FEATURES
COMPONENT & CONTROL LOCATIONS
Use the illustrations on these pages to locate and identify the most frequently
used controls.
PARALLEL OPERATION
OUTLETS
AC RECEPTACLES
ECO THROTTLE SWITCH
GROUND TERMINAL
OIL ALERT/CHECK
INDICATOR
OVERLOAD ALARM
INDICATOR
OUTPUT INDICATOR
FUEL FILLER CAP VENT LEVER
FUEL FILLER CAP
STARTER GRIP
CHOKE LEVER
MAINTENANCE
COVER
ENGINE SWITCH
CO-MINDER

CONTROLS & FEATURES
19
SPARK PLUG MAINTENANCE COVER
MUFFLER
SPARK PLUG

CONTROLS & FEATURES
20
CONTROLS
Engine Switch
The engine switch controls the
ignition system and the fuel valve.
OFF – Stops the engine and closes the
fuel valve.
ON – Running position; opens the fuel
valve and allows the engine to be
started.
Starter Grip
Pulling the starter grip operates the
recoil starter to start the engine.
Do not allow the starter grip to snap
back against the generator. Return it
gently to prevent damage to the starter.
ENGINE SWITCH
STARTER GRIP
OFF
ON

CONTROLS & FEATURES
21
Fuel Filler Cap Vent Lever
The fuel filler cap is provided with a vent lever to seal the fuel tank.
The fuel filler cap vent lever must be in the ON position for the engine to run.
When the engine is not in use, leave the fuel filler cap vent lever in the OFF
position to reduce the possibility of fuel leakage. Allow the engine to cool
before turning the fuel filler cap vent lever to the OFF position.
Choke Lever
The choke is used to provide proper
starting mixture when the engine is
cold. It can be opened and closed by
operating the choke lever manually.
Move the choke lever to the CLOSED
position to enrich the mixture for cold
starting.
OFF
ON
FUEL FILLER CAP
FUEL FILLER CAP VENT LEVER
CHOKE LEVER
OPEN
CLOSED

CONTROLS & FEATURES
22
Eco Throttle® Switch
The Eco Throttle® system automatically reduces engine speed when loads are
turned off or disconnected. When appliances are turned on or reconnected, the
engine returns to the proper speed to power the electrical load.
If high electrical loads are connected simultaneously, turn the Eco Throttle
switch to the OFF position to reduce voltage changes.
ON - Recommended to minimize fuel consumption and further reduce noise
levels when less than a full load is applied to the generator.
OFF - The Eco Throttle system does not operate.
ECO THROTTLE SWITCH
OFF
ON

CONTROLS & FEATURES
23
CO-MINDER (CO Shut-off System)
CO-MINDER is a system that automatically stops the engine before the
surrounding carbon monoxide concentration exceeds a certain level.
If the CO-MINDER detects a high carbon monoxide concentration, the engine
will stop and the CO ALARM indicator will flash for about five minutes.
Continuously using the generator in areas with high concentrations of carbon
monoxide can cause serious health hazards due to carbon monoxide poisoning
(see page 7). If you are in the same area as the generator, evacuate the area
immediately. Get fresh air and seek medical attention immediately if you feel
sick or suspect you have inhaled carbon monoxide. Ventilate the area or space
where the generator is located.
If the engine is stopped by the CO-MINDER system, change the operating
location of the generator.
• Do not operate the generator in an enclosed or partly enclosed area such as a
garage.
• Do not enclose or cover the generator with boards or a tent, even when it is
outside and away from of a building.
• Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other
structures, or vehicles (see page 46).
• Avoid placing the generator near devices that emit carbon monoxide, such as
another generator.
• When operating generators in parallel operation, place the generators so that
the exhaust from one generator is not directed onto the other generator (see
page 46).
The Oil Alert/Check Indicator also comes ON when the engine is automatically
stopped by the CO-MINDER.
CO-MINDER RESET BUTTON
CO ALARM INDICATOR
FAULT/CO SENSOR LIFE
INDICATOR

CONTROLS & FEATURES
24
RESTARTING THE ENGINE
When the engine is stopped automatically by CO-MINDER, press the CO-
MINDER reset button to restart the engine.
If the engine is restarted without pressing the CO-MINDER reset button, the
engine will automatically stop immediately after restarting and the CO ALARM
indicator will flash for approximately five minutes.
Resetting the CO-MINDER is possible only after the CO ALARM indicator is
turned off.
CO-MINDER MALFUNCTION DETECTION
If the CO-MINDER detects a system malfunction, the engine will stop
automatically and the FAULT/CO SENSOR LIFE indicator will flash for
approximately five minutes. Press the CO-MINDER reset button to turn off the
FAULT/CO SENSOR LIFE indicator. If the engine will not remain running after
attempting to restart it and the FAULT/CO SENSOR LIFE indicator comes on
again, there may be a system malfunction. If this occurs, do not attempt to
restart the generator more than two times. If the CO-MINDER system is
malfunctioning, it cannot warn you of potential high concentrations of carbon
monoxide. Move the generator to a well-ventilated location and consult an
authorized Honda Power Equipment dealer.
CO SENSOR LIFE
If the FAULT/CO SENSOR LIFE indicator flashes when operating the generator,
the CO-MINDER may be reaching the end of its useful lifespan and will
eventually need replacement.
• If the indicator flashes once every four seconds, this means there is
approximately six months to one year of life left in the CO-MINDER.
• If the indicator flashes once every two seconds, this means there is
approximately six months of life or less left in the CO-MINDER.
• The FAULT/CO SENSOR LIFE indicator indicates the estimated life left in the CO-
MINDER.
• The generator stopping period and storage period are also included in the useful
lifespan of the CO-MINDER.
• Contact an authorized Honda Power Equipment dealer for CO-MINDER
replacement.

CONTROLS & FEATURES
25
Parallel Operation Outlets
These outlets are used for connecting two EU1000i generators for parallel
operation (see page 43). A Honda-approved parallel operation cable (optional
equipment) is required for parallel operation. This cable can be purchased from
an authorized Honda Power Equipment dealer.
PARALLEL OPERATION
OUTLETS

CONTROLS & FEATURES
26
FEATURES
Output Indicator
The output indicator (green) is illuminated when the generator is operating
normally. It indicates that the generator is producing electrical power at the
receptacles.
In addition, the output indicator has a simplified hour meter function. When you
start the engine, the indicator blinks according to the generator’s cumulative
operating hours as follows:
• No blinks: 0–100 hours
• 1 blink: 100–200 hours
• 2 blinks: 200–300 hours
• 3 blinks: 300–400 hours
• 4 blinks: 400–500 hours
• 5 blinks: 500 or more hours
Overload Alarm (Indicator)
If the generator is overloaded (in excess of 1.0 kVA), or if there is a short circuit in
a connected appliance, the overload alarm indicator (red) will come ON. The
overload alarm indicator (red) will stay ON, and after about four seconds,
current to the connected appliance(s) will shut off, and the output indicator
(green) will go OFF. However, the engine will continue to run.
OUTPUT INDICATOR
(GREEN)
OVERLOAD ALARM INDICATOR
(RED)

CONTROLS & FEATURES
27
Oil Alert®/Check Indicator
The Oil Alert® system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
can fall below a safe limit, the Oil Alert/Check indicator (red) comes ON and the
Oil Alert system automatically will stop the engine (the engine switch will
remain in the ON position).
If the engine stops or the Oil Alert/Check indicator (red) comes ON when you
pull the starter grip, check the engine oil level (see page 30) before
troubleshooting in other areas.
The Oil Alert/Check Indicator also comes ON when the engine is automatically
stopped by the CO-MINDER.
Ground Terminal
The generator ground terminal is connected to the frame of the generator, the
metal non-current-carrying parts of the generator, and the ground terminals of
each receptacle.
Before using the ground terminal, consult a qualified electrician, electrical
inspector, or local agency having jurisdiction for local codes or ordinances that
apply to the intended use of the generator.
NEUTRAL FLOATING:
• The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
• Electrical devices that require a grounded receptacle pin connection will not
function if the receptacle ground pin is not functional.
OIL ALERT/CHECK INDICATOR
(RED)
GROUND TERMINAL

28
BEFORE OPERATION
ARE YOU READY TO GET STARTED?
Your safety is your responsibility. A little time spent in preparation will
significantly reduce your risk of injury.
Knowledge
Read and understand this manual. Know what the controls do and how to
operate them.
Familiarize yourself with the generator and its operation before you begin using
it. Know how to quickly shut off the generator in case of an emergency.
If the generator is being used to power appliances, be sure that they do not
exceed the generator’s load rating (see pages 42 and 47).
IS YOUR GENERATOR READY TO GO?
For your safety, to ensure compliance with environmental regulations, and to
maximize the service life of your equipment, it is very important to take a few
moments before you operate the generator to check its condition. Be sure to
take care of any problem you find, or have your servicing dealer correct it,
before you operate the generator.
Failure to properly maintain this
generator, or failing to correct a problem
before operation, could result in a
significant malfunction.
Some malfunctions can cause serious
injuries or death.
Always perform a pre-operation
inspection before each operation and
correct any problems.

BEFORE OPERATION
29
To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from
building walls and other equipment during operation. Do not place flammable
objects close to the engine.
Before beginning your pre-operation checks, be sure the generator is on a level
and firm surface and the engine switch is in the OFF position.
Check the Engine
• Before each use, look around and underneath the engine for signs of oil or
gasoline leaks.
• Check the engine oil level (see page 30). A low engine oil level will cause the
Oil Alert system to shut down the engine.
• Check the air filter (see page 32). A dirty air filter will restrict air flow to the
carburetor, reducing engine and generator performance.
• Check the fuel level (see page 14). Starting with a full tank will help to
eliminate or reduce operating interruptions for refueling.
AC Appliance and Power Cord
Before connecting an AC appliance or power cord to the generator:
• Use grounded 3-prong extension cords, tools, and appliances, or double-
insulated tools and appliances.
• Inspect cords and plugs, and replace if damaged.
• Make sure that the appliance is in good working order. Faulty appliances or
power cords can create a potential for electric shock.
• Make sure the electrical rating of the tool or appliance does not exceed the
rated power of the generator or the receptacle being used.
• Do not exceed the current limit specified for any one receptacle.

BEFORE OPERATION
30
ENGINE OIL LEVEL CHECK
Check the engine oil level with the generator on a level surface and the engine
stopped.
1. Loosen the maintenance cover screw and remove the maintenance cover.
2. Remove the oil filler cap by turning it counterclockwise. Wipe the dipstick
clean.
3. Insert the dipstick into the oil filler neck as shown, but do not screw it in, then
remove it to check the oil level.
4. If the oil level is near or below the lower limit, fill with the recommended oil
to the upper limit. Do not overfill.
• "Upper limit" means the oil exists to the oil filler neck.
• "Lower limit" means the oil is attached only to the lower end of the
dipstick.
Refer to "ENGINE OIL RECOMMENDATIONS" in page 13.
5. Reinstall the oil filler cap securely.
MAINTENANCE COVER SCREW
MAINTENANCE COVER

BEFORE OPERATION
31
6. Reinstall the maintenance cover and tighten the maintenance cover screw
securely.
The Oil Alert system will automatically stop the engine before the oil level falls
below safe limits. However, to avoid the inconvenience of an unexpected
shutdown, check the oil level regularly.
OIL FILLER NECK
OIL FILLER CAP
UPPER LIMIT
(The oil exists to the
oil filler neck.)
LOWER LIMIT
(The oil is attached
only to the lower end
of the dipstick.)
DIPSTICK

BEFORE OPERATION
32
AIR FILTER CHECK
1. Loosen the maintenance cover screw
and remove the maintenance cover.
2. Press the latch tab on the top of the
air cleaner case, and remove the air
cleaner cover.
3. Check the foam air filter to be sure it is
clean and in good condition. If the
foam air filter is dirty, clean it as
described on page 55. Replace the
foam air filter if it is damaged.
4. Reinstall the air filter.
5. Make sure that the rubber seal is set
in the groove of the air cleaner cover.
6. Reinstall the air cleaner cover by
inserting the lower tab and the latch
tab.
7. Reinstall the maintenance cover, and
tighten the maintenance cover screw
securely.
Operating the engine without an air filter or with a damaged air filter will allow dirt
to enter the engine, causing rapid engine wear. This type of damage is not covered
by the Distributor’s Limited Warranty.
MAINTENANCE COVER SCREW
MAINTENANCE COVER
AIR CLEANER CASE
FOAM AIR
FILTER
AIR CLEANER
COVER
RUBBER SEAL
LATCH TAB
LOWER TAB

BEFORE OPERATION
33
SAFE OPERATING PRECAUTIONS
Before operating the generator, review chapters "GENERATOR SAFETY" (see
page 6).
For your safety, do not operate the generator in an enclosed, or partly enclosed
area such as a garage (even if the door is open) or near structures or vehicles.
Your generator's exhaust contains poisonous carbon monoxide gas that can
collect rapidly in such areas, structures, vehicles, trailers, or boats.
• Do not operate the generator when it is in a storage, cargo, or security
enclosure, including any RV generator bay.
• Always completely remove the generator from the vehicle, trailer, boat or
other equipment or structure during operation.
• The generator must remain stationary while in operation.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.

34
OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from
building or trailer walls, vehicles, trailers, boats, and other equipment during
operation. Do not place flammable objects close to the engine.
• Operating this generator less than 3 feet (1 meter) from a building, obstruction, or
when it is in an enclosure, a storage or security compartment/bay, can cause
overheating and damage the generator.
• For proper cooling, allow at least 3 feet (1 meter) of empty space above and
around the generator.
Keep all cooling holes open and clear of debris, mud, water, etc. Cooling holes are
located on the side panel, the control panel, and the bottom of the generator. If
the cooling holes are blocked, the generator may overheat and damage the
engine, inverter, or windings.
• Since the CO-MINDER may detect the carbon monoxide concentration and the
engine may stop automatically, pay attention to the direction of exhaust and
where the generator is located (see page 23).
Refer to "SAFE OPERATING PRECAUTIONS" on page 33 and perform the "IS
YOUR GENERATOR READY TO GO?" checks (see page 28).
Refer to "AC OPERATION" (see page 40) for connecting loads to the generator.
1. Make sure that all appliances are disconnected from the AC receptacle.
2. Turn the fuel filler cap vent lever to the ON position.
FUEL FILLER CAP VENT LEVER
OFF
ON

OPERATION
35
3. Make sure the Eco Throttle switch is
in the OFF position, or more time
will be required for warm-up.
4. To start a cold engine, move the
choke lever to the CLOSED position.
To restart a warm engine, leave the
choke lever in the OPEN position.
5. Turn the engine switch to the ON
position.
ECO THROTTLE SWITCH
OFF
CHOKE LEVER
OPEN
CLOSED
ENGINE SWITCH
OFF
ON

OPERATION
36
6. Pull the starter grip lightly until you
feel resistance; then pull briskly in
the direction of the arrow as shown.
Do not allow the starter grip to snap
back against the generator. Return it
gently to prevent damage to the
starter.
7. If the choke lever was moved to the
CLOSED position to start the
engine, gradually move it to the
OPEN position as the engine warms
up.
8. If you wish to use the Eco Throttle
system, turn the Eco Throttle switch
to the ON position after the engine
has warmed up for 2 or 3 minutes.
STARTER GRIP
Direction to pull
CLOSED
CHOKE LEVER
OPEN
ECO THROTTLE SWITCH
ON

OPERATION
37
STOPPING THE ENGINE
To stop the engine in an emergency, simply turn the engine switch to the OFF
position. Under normal conditions, use the following procedure.
1. Turn off or disconnect all appliances that are connected to the generator.
2. Turn the engine switch to the OFF position.
3. Allow the engine to cool, and then turn the fuel filler cap vent lever to the OFF
position.
ENGINE SWITCH
OFF
ON
FUEL FILLER CAP VENT LEVER
OFF
ON

OPERATION
38
4. If two generators were connected for parallel operation, disconnect the
parallel operation cable after stopping the engines if you do not wish to
resume parallel operation.
PARALLEL OPERATION CABLE
(optional equipment)

OPERATION
39
HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)
When the engine is automatically stopped by the CO-MINDER, move the
generator to an area with fresh air and away from any device that may be
emitting carbon monoxide, such as another generator. Press the CO-MINDER
reset button and then follow the standard procedure for starting the engine.
When the CO ALARM indicator or the FAULT/CO-MINDER LIFE indicator flashes,
press the CO-MINDER reset button to turn off the indicator.
• After the engine is stopped by the CO-MINDER (CO Shut-off System), the engine
cannot be restarted for approximately 30 seconds.
• The Oil Alert/Check Indicator also comes ON when the engine is automatically
stopped by the CO-MINDER.
CO-MINDER RESET BUTTON
CO ALARM INDICATOR
FAULT/CO SENSOR LIFE
INDICATOR

OPERATION
40
AC OPERATION
Before connecting an appliance to the generator, make sure that it is in good
working order and that its electrical rating does not exceed that of the
generator.
Most motorized appliances require more than their electrical rating for startup.
When an electric motor is started, the overload alarm indicator (red) may come
ON. This is normal if the overload alarm indicator (red) goes OFF within 4
seconds. If the overload alarm indicator (red) stays ON, consult an authorized
Honda Power Equipment dealer.
1. Start the engine (see page 34) and make sure the output indicator (green)
comes ON.
OUTPUT INDICATOR (GREEN) OVERLOAD ALARM INDICATOR (RED)

OPERATION
41
2. Plug the appliance into the receptacle.
3. Turn on the appliance.
If the generator is overloaded (see page 42), or if there is a short circuit in a
connected appliance, the overload alarm indicator (red) will go ON. The
overload alarm indicator (red) will stay ON, and after about four seconds, current
to the connected appliance(s) will shut off, and the output indicator (green) will
go OFF. Stop the engine and investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an overload.
Correct the problem and restart the generator.

OPERATION
42
AC Applications
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. A faulty appliance or power cord
can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is the appliance or the rated load capacity of the
generator has been exceeded.
Most appliance motors require more than their rated wattage for startup.
Make sure the electrical rating of the tool or appliance does not exceed the
maximum power rating of the generator.
Maximum power is:
1.0 kVA
For continuous operation, do not exceed the rated power.
Rated power is:
0.9 kVA
In either case, the total power requirements (VA) of all appliances connected
must be considered. Appliance and power tool manufacturers usually list rating
information near the model number or serial number.
Substantial overloading that continuously lights the overload alarm indicator (red)
may damage the generator. Marginal overloading that temporarily lights the
overload alarm indicator (red) may shorten the service life of the generator.

OPERATION
43
AC PARALLEL OPERATION
Before connecting an appliance to either generator, make sure that the
appliance is in good working order and that its electrical rating does not exceed
that of the receptacle.
Most motorized appliances require more than their electrical rating for startup.
When an electric motor is started, the overload alarm indicator (red) may come
ON. This is normal if the overload alarm indicator (red) goes OFF within 4
seconds. If the overload alarm indicator (red) stays ON, consult an authorized
Honda Power Equipment dealer.
During parallel operation, the Eco Throttle switch should be in the same
position on both generators.
1. Connect the parallel operation cable (optional equipment) between the two
EU1000i generators following the instructions supplied with the parallel
operation cable.
2. Start the engines (see page 34) and make sure the output indicator (green) on
each generator comes ON (see page 40).
PARALLEL OPERATION CABLE
(optional equipment)

OPERATION
44
3. Plug the appliance following the instruction provided with the parallel
operation cable.
4. Turn on the appliance.
If the generators are overloaded (see page 47), or if there is a short circuit in a
connected appliance, the overload alarm indicator (red) will go ON. The
overload alarm indicator (red) will stay ON, and after about four seconds, current
to the connected appliance(s) will shut off, and the output indicator (green) will
go OFF. Stop both engines and investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an overload.
Correct the problem and restart the generator.

OPERATION
45
AC Parallel Operation Applications
Follow the instructions included with the parallel operation cable. Before
connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. A faulty appliance or power cord
can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is the appliance or the rated load capacity of the
generator has been exceeded.
• Never connect different generator models.
• Use only a Honda-approved parallel operation cable (optional equipment,
see page 77) when connecting two EU1000i generators for parallel operation.
• Never connect or remove the parallel operation cable when the generator is
running.
• For single generator operation, the parallel operation cable must be
removed.

OPERATION
46
When operating generators in parallel operation, if one generator emits exhaust
toward the other, the CO-MINDER (CO Shut-off System) of the generator that is
receiving the exhaust may stop the engine. Pay attention to the following for
placing generators in parallel operation.
• Align the two generators so that their mufflers are on the same line and exhaust in
the same direction.
• Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other structures,
or vehicles.
EXHAUST
EXHAUST
ON THE SAME LINE
WIND DIRECTION
WIND DIRECTION
This generator may detect exhaust from the
adjacent generator and will stop the engine.
OK INCORRECT
MUFFLER

OPERATION
47
Most appliance motors require more than their rated wattage for startup.
Make sure the electrical rating of the tool or appliance does not exceed the
maximum power rating of the generator.
Maximum power in parallel operation is:
2.0 kVA
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is:
1.8 kVA
In either case, the total power requirements (VA) of all appliances connected
must be considered. Appliance and power tool manufacturers usually list rating
information near the model number or serial number.
Substantial overloading that continuously lights the overload alarm indicator (red)
may damage the generator. Marginal overloading that temporarily lights the
overload alarm indicator (red)) may shorten the service life of the generator.

OPERATION
48
ECO THROTTLE® SYSTEM
With the switch in the ON position, engine speed is automatically lowered when
loads are reduced, turned off, or disconnected. When appliances are turned on
or reconnected, the engine returns to the proper speed to power the electrical
load. In the OFF position, the Eco Throttle® system does not operate.
Appliances with large start-up power demands may not allow the engine to
reach normal operating rpm when they are connected to the generator. Turn
the Eco Throttle switch to the OFF position and connect the appliance to the
generator. If the engine still will not reach normal operating speed, check that
the appliance does not exceed the rated load capacity of the generator.
If high electrical loads are connected simultaneously, turn the Eco Throttle
switch to the OFF position to reduce voltage changes.
The Eco Throttle system is not effective for use with appliances or tools that
require only momentary power. If the tool or appliance will be turned ON and
OFF quickly, the Eco Throttle switch should be in the OFF position.
ECO THROTTLE SWITCH
OFF
ON

OPERATION
49
STANDBY POWER
Connections to a Building’s Electrical System
Connections for standby power to a building’s electrical system must be made
by a qualified electrician. The connection must isolate the generator power
from utility power, and must comply with all applicable laws and electrical
codes.
In some areas, generators are required by law to be registered with local utility
companies. Check local regulations for proper registration and use procedures.
System Ground
This generator has a system ground that connects generator frame components
to ground terminals in the AC output receptacles. The system ground is not
connected to the AC neutral wire.
Improper connections to a building’s
electrical system can allow current from
the generator to backfeed into the
utility lines.
Such backfeed may electrocute utility
company workers or others who contact
the lines during a power outage, and the
generator may explode, burn, or cause
fires when utility power is restored.
Consult the utility company or a
qualified electrician prior to making any
power connections.

OPERATION
50
Special Requirements
Do not lay the generator on its side when moving, storing, or operating it. Oil and
fuel may leak and damage the engine or your property.
There may be Federal or State Occupational Safety and Health Administration
(OSHA) regulations, local codes, or ordinances that apply to the intended use of
the generator. Please consult a qualified electrician, electrical inspector, or the
local agency having jurisdiction.
• In some areas, generators are required to be registered with local utility
companies.
• If the generator is used at a construction site, there may be additional
regulations that must be observed.

51
SERVICING YOUR GENERATOR
THE IMPORTANCE OF MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation.
It will also help reduce air pollution.
To help you properly care for your generator, the following pages include a
maintenance schedule, routine inspection procedures, and simple maintenance
procedures using basic hand tools. Other service tasks that are more difficult or
require special tools are best handled by professionals and are normally
performed by a Honda technician or other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If you
operate your generator under unusual conditions, such as sustained high-load
or high-temperature operation, or use it in dusty conditions, consult your
servicing dealer for recommendations applicable to your individual needs and
use.
Remember that an authorized Honda Power Equipment dealer knows your
generator best and is fully equipped to maintain and repair it.
To ensure the best quality and reliability, use only new, Honda Genuine parts or
their equivalents for repair and replacement.
Maintenance, replacement, or repair of the emission control devices and
systems may be performed by any engine repair establishment or
individual, using parts that are “certified” to EPA standards.
Failure to properly maintain this
generator, or failing to correct a problem
before operation, could result in a
significant malfunction.
Some malfunctions can cause serious
injuries or death.
Always follow the inspection and
maintenance recommendations and
schedules in this owner’s manual.

SERVICING YOUR GENERATOR
52
MAINTENANCE SAFETY
Some of the most important safety precautions follow. However, we cannot
warn you of every conceivable hazard that can arise in performing
maintenance. Only you can decide whether or not you should perform a given
task.
Safety Precautions
Read the instructions before you begin, and make sure you have the tools and
skills required.
• Make sure the engine is off before you begin any maintenance or repairs. This
will eliminate several potential hazards:
– Carbon monoxide poisoning from engine exhaust
Operate outside away from open windows or doors with engine exhaust
directed away from occupied structures.
– Burns from hot parts
Let the engine and exhaust system cool before touching.
– Injury from moving parts
Do not run the engine unless instructed to do so.
• To reduce the possibility of fire or explosion, be careful when working around
gasoline. Use only a non-flammable solvent, not gasoline, to clean parts. Keep
cigarettes, sparks, and flames away from all fuel-related parts.
Improper maintenance can cause an
unsafe condition.
Failure to properly follow maintenance
instructions and precautions can cause
serious injuries or death.
Always follow the procedures and
precautions in this owner’s manual.

SERVICING YOUR GENERATOR
53
MAINTENANCE SCHEDULE
Failure to follow this maintenance schedule could result in non-warrantable
failures.
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, unless you have the proper tools and are
mechanically proficient. Refer to the Honda shop manual for service procedures.
See "Honda PUBLICATIONS" on page 77 for ordering information.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Turn the engine switch and fuel filler cap vent lever to the OFF position (see
page 37) to reduce the possibility of fuel leakage.
2. Loosen the maintenance cover screw and remove the maintenance cover
(see page 30).
3. Place a suitable container next to the engine to catch the used oil.
REGULAR SERVICE PERIOD (3)
Perform at every indicated month
or operating hour interval,
whichever comes first.
ITEM
Each
use
First
month
or
10 hrs.
Every
3
months
or
50 hrs.
Every
6
months
or
100 hrs.
Every
2 years
or
300 hrs.
Page
Engine oil Check level o 30
Change o o 53
Air cleaner Check o 32
Clean o (1) 55
Spark plug Check-adjust o 56
Replace o 56
Spark arrester Clean o 58
Valve clearance Check-adjust o (2) —
Combustion chamber Clean After every 300 hrs. (2) —
Fuel tank and filter Clean Every year (2) —
Fuel tube Check Every 2 years (Replace if necessary) (2) —

SERVICING YOUR GENERATOR
54
4. Remove the oil filler cap, and drain the oil into the container by tipping the
engine toward the oil filler neck.
Improper disposal of engine oil can be harmful to the environment.
If you change your own oil, please dispose of the used oil properly. Put it in a
sealed container, and take it to a recycling center. Do not discard it in a trash bin,
dump it on the ground, or pour it down the drain.
5. With the generator in a level position, fill with the recommended oil to the
upper limit. Do not overfill.
• “Upper limit” means the oil exists to the oil filler neck. Refer to "ENGINE OIL
RECOMMENDATIONS" in page 13.
Maximum oil capacity: 8 oz (0.25 L)
6. Reinstall the oil filler cap securely.
7. Reinstall the maintenance cover and tighten the maintenance cover screw
securely.
Wash your hands with soap and water after handling used oil.
OIL FILLER NECK
UPPER LIMIT
(The oil exists to the
oil filler neck.)
OIL FILLER CAP

SERVICING YOUR GENERATOR
55
AIR CLEANER SERVICE
Foam Air Filter Cleaning
A dirty foam air filter will restrict air flow to the carburetor, reducing engine
performance. If you operate the generator in very dusty areas, clean the foam
air filter more frequently than specified in the Maintenance Schedule (see page
53).
1. Clean the air filter in warm soapy water, rinse, and allow to dry thoroughly, or
clean in nonflammable solvent and allow to dry.
2. Dip the air filter in clean engine oil, and then squeeze out all excess oil. The
engine will smoke when started if too much oil is left in the air filter.
3. Remove the rubber air guide from the air cleaner case.
Clean the rubber air guide and the air cleaner case with a moist rag, then
reinstall the rubber air guide.
Clean
Squeeze and dry
Dip in oil
Squeeze
Do not twist. Do not twist.
AIR CLEANER CASE
RUBBER AIR GUIDE

SERVICING YOUR GENERATOR
56
SPARK PLUG SERVICE
In order to service the spark plug, you will need a spark plug wrench
(commercially available).
Required spark plug: LR4C-E (NGK)
To ensure proper engine operation, the spark plug must be properly gapped
and free of deposits.
An incorrect spark plug can cause engine damage.
If the engine is hot, allow it to cool before servicing the spark plug.
1. Remove the spark plug maintenance cover.
2. Disconnect the spark plug cap, and remove any dirt from around the spark
plug area.
3. Remove the spark plug with a spark plug wrench.
SPARK PLUG
MAINTENANCE COVER
SPARK PLUG CAP
SPARK PLUG CAP
SPARK PLUG WRENCH

SERVICING YOUR GENERATOR
57
4. Inspect the spark plug. Replace it if
the electrodes are worn or fouled, or if
the insulator is cracked or chipped.
Clean the spark plug with a wire
brush if it is to be reused.
5. Measure the spark plug electrode gap
with a wire-type feeler gauge. Correct
the gap, if necessary, by carefully
bending the side electrode.
Spark plug gap:
0.024–0.028 in (0.6–0.7 mm)
6. Make sure that the spark plug sealing washer is in good condition, and thread
the spark plug in by hand to prevent cross-threading.
7. After the spark plug is seated, tighten with a spark plug wrench to compress
the washer.
If reinstalling a used spark plug, tighten 1/8–1/4 turn after the spark plug is
seated.
If installing a new spark plug, tighten 1/2 turn after the spark plug is seated.
Torque: 8.7 lbf∙ft (11.8 N∙m, 1.2 kgf∙m)
A loose spark plug can overheat and damage the engine.
Overtightening the spark plug can damage the threads in the cylinder head.
8. Reinstall the spark plug cap on the spark plug securely.
9. Reinstall the spark plug maintenance cover.
SIDE ELECTRODE
0.024–0.028 in
(0.6–0.7 mm)
SEALING WASHER
INSULATOR

SERVICING YOUR GENERATOR
58
SPARK ARRESTER SERVICE
The spark arrester must be serviced every 100 hours to keep it functioning as
designed.
If the engine has been running, the muffler will be very hot. Allow the muffler to
cool before servicing the spark arrester.
Clean the spark arrester as follows:
1. Remove the four 5 mm screws, and remove the muffler protector.
2. Remove the three 6 mm bolts, and remove the muffler, the spark arrester, and
the muffler gasket.
MUFFLER PROTECTOR
5 mm SCREWS
MUFFLER GASKET
6 mm BOLTS
SPARK ARRESTER
MUFFLER

SERVICING YOUR GENERATOR
59
3. Use a brush to remove carbon deposits from the spark arrester screen.
Be careful to avoid damaging the screen.
The spark arrester must be free of breaks and tears. Replace the spark arrester
if it is damaged.
4. Check the muffler gasket; replace if damaged.
Reinstall the muffler gasket, the spark arrester, the muffler, and the muffler
protector in the reverse order of removal.

60
STORAGE
STORAGE PREPARATION
Proper storage preparation is essential for keeping your generator trouble-free
and looking good. The following steps will help to keep rust and corrosion from
impairing your generator’s function and appearance, and will make the engine
easier to start when you use the generator again.
Cleaning
Wipe the generator with a moist cloth. After the generator has dried, touch up
any damaged paint, and coat other areas that may rust with a light film of oil.
Fuel
Depending on the region where you operate your equipment, fuel formulations may
deteriorate and oxidize rapidly. Fuel deterioration and oxidation can occur in as
little as 30 days and may cause damage to the carburetor and/or fuel system. Please
check with your servicing dealer for local storage recommendations.
Gasoline will oxidize and deteriorate in storage. Old gasoline will cause hard
starting, and it leaves gum deposits that clog the fuel system. If the gasoline in
your generator deteriorates during storage, you may need to have the
carburetor and other fuel system components serviced or replaced.
The length of time that gasoline can be left in your fuel tank and carburetor
without causing functional problems will vary with such factors as gasoline
blend, your storage temperatures, and whether the fuel tank is partly or
completely filled. The air in a partly filled fuel tank promotes fuel deterioration.
Very warm storage temperatures accelerate fuel deterioration. Fuel
deterioration problems may occur within a few months, or even less if the
gasoline was not fresh when you filled the fuel tank.
The Distributor’s Limited Warranty does not cover fuel system damage or engine
performance problems resulting from neglected storage preparation.
You can extend fuel storage life by adding a gasoline stabilizer that is
formulated for that purpose, or you can avoid fuel deterioration problems by
draining the fuel tank and carburetor.

STORAGE
61
Service according to the table below:
DRAINING THE FUEL TANK AND CARBURETOR
1. Unscrew the fuel filler cap (see page 15), remove the fuel strainer, and empty
the fuel tank into an approved gasoline container. We recommend using a
commercially available gasoline hand pump to empty the tank. Do not use an
electric pump. Reinstall the fuel strainer and the fuel filler cap.
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month No preparation required.
1 to 2 months Fill with fresh gasoline and add gasoline stabilizer*.
2 months to 1 year Fill with fresh gasoline and add gasoline stabilizer*.
Turn the engine switch to the OFF position and drain
the carburetor float bowl (see page 61).
1 year or more Drain the fuel tank and carburetor (see page 61).
Change the engine oil and lubricate the cylinder (see
page 63).
*Use gasoline stabilizers that are formulated to extend storage life.
Follow the manufacturer’s instructions for use.
Contact your authorized Honda Power Equipment dealer for stabilizer
recommendations.
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.

STORAGE
62
2. Loosen the maintenance cover screw and remove the maintenance cover
(see page 30).
3. Loosen the carburetor drain screw, and drain the gasoline from the
carburetor into a suitable container.
4. Remove the spark plug maintenance cover, and the spark plug cap (see
page 56).
5. Turn the engine switch to the ON position (see page 35).
6. Pull the starter grip (see page 36) 3 to 4 times to drain the gasoline from the
fuel pump into a suitable container.
7. Turn the engine switch to the OFF position.
8. Tighten the carburetor drain screw.
CARBURETOR DRAIN SCREW
FUEL STRAINER
FUEL FILLER CAP

STORAGE
63
Engine Oil
Change the engine oil (see page 53).
Engine Cylinder
1. Remove the spark plug (see page 56), and pour approximately one teaspoon
(5 cc) of clean engine oil into the cylinder. Crank the engine several
revolutions to distribute the oil, and then reinstall the spark plug.
2. Reinstall the spark plug cap on the spark plug securely.
3. Reinstall the spark plug maintenance cover.
4. Reinstall the maintenance cover and tighten the maintenance cover screw
securely.
5. Pull the starter grip (see page 36) slowly until you feel resistance, and then
return the starter grip gently. This closes the valves so moisture cannot enter.

STORAGE
64
STORAGE PRECAUTIONS
If your generator will be stored with gasoline in the fuel tank and carburetor, it is
important to reduce the hazard of gasoline vapor ignition.
Select a well-ventilated storage area away from any appliance that operates
with a flame, such as a furnace, water heater, or clothes dryer.
Also avoid any area with a spark-producing electric motor, or where power tools
are operated.
If possible, avoid storage areas with high humidity, because that promotes rust
and corrosion.
Unless all fuel has been drained from the fuel tank, leave the engine switch in
the OFF position, and the fuel filler cap vent lever in the OFF position (see
page 37) to reduce the possibility of leakage.
Place the generator on a level surface. Tilting or laying it on its side can cause
fuel or oil leakage.
With the engine and exhaust system cool, cover the generator to keep out dust.
A hot engine and exhaust system can ignite or melt some materials.
Do not use a plastic sheet as a dust cover. A nonporous cover will trap moisture
around the generator, promoting rust and corrosion.
REMOVAL FROM STORAGE
Check your generator as described in the "BEFORE OPERATION" chapter of this
manual (see page 28).
If the fuel was drained during storage preparation, fill the tank with fresh
gasoline. If you keep a container of gasoline for refueling, be sure that it
contains only fresh gasoline. Gasoline oxidizes and deteriorates over time,
causing hard starting.
If the cylinder was coated with oil during storage preparation, the engine may
smoke briefly at startup. This is normal.

65
TRANSPORTING
To prevent spillage when transporting, the generator should be secured upright
in its normal operating position, with the engine switch OFF and the fuel filler
cap vent lever turned fully counterclockwise to the OFF position (see page 37).
Do not lay the generator on its side when moving, storing, or operating it. Oil may
leak and damage the engine or your property.
Do not operate the generator while it is being transported or while it is
mounted to any type of vehicle, trailer, or boat.
Take care not to drop or strike the generator when transporting. Do not place
heavy objects on the generator.
An engine that has been running will
remain very hot for a period of time.
A hot engine and exhaust system can
burn you and ignite some material.
If the generator has been used, allow it
to cool for at least 15 minutes before
loading the generator on the transport
vehicle.

66
TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE WILL NOT START
Possible Cause Correction
Fuel filler cap vent lever is in the
OFF position.
Turn the fuel filler cap vent lever to the ON
position (see page 21).
Engine switch is in the OFF
position.
Turn the engine switch to the ON position
(see page 20).
Out of fuel. Refuel (see page 15).
Bad fuel, generator stored
without treating or draining
gasoline, or refueled with bad
gasoline.
Drain fuel tank and carburetor (see
page 61).
Refuel with fresh gasoline (see page 15).
Low engine oil level caused Oil
Alert to stop engine.
Turn the engine switch to the OFF position.
Add engine oil. Then turn the engine
switch to the ON position and restart the
engine.
Spark plug faulty, fouled, or
improperly gapped.
Gap or replace spark plug (see page 56).
Spark plug wet with fuel (flooded
engine).
Dry and reinstall spark plug.
Fuel strainer restricted, carburetor
malfunction, ignition
malfunction, valves stuck, etc.
Take the generator to an authorized Honda
Power Equipment dealer, or refer to the
shop manual.
CO-MINDER (CO Shut-off System)
is detecting high carbon
monoxide (CO) levels around the
generator.
Review the location of the generator, such
as by placing it in a well-ventilated outdoor
location (see page 23).
When the engine is stopped automatically
by CO-MINDER, press the CO-MINDER reset
button to restart the engine (see page 39).

TAKING CARE OF UNEXPECTED PROBLEMS
67
ENGINE LACKS POWER
NO POWER AT THE AC RECEPTACLES
Possible Cause Correction
Air filter restricted. Clean or replace air filter
(see pages 32, 55).
Bad fuel, generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank and carburetor
(see page 61).
Refuel with fresh gasoline
(see page 15).
Fuel strainer restricted, carburetor
malfunction, ignition malfunction,
valves stuck, etc.
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
Possible Cause Correction
Output indicator is OFF, and overload
alarm indicator is ON.
Check AC load. Stop and restart the
engine.
Check the cooling air inlet. Stop and
restart the engine.
Faulty power tool or appliance. Replace or repair power tool or
appliance.
Stop and restart the engine.
Faulty generator. Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.

TAKING CARE OF UNEXPECTED PROBLEMS
68
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE
ENGINE
Possible Cause Correction
CO concentration around the
generator is high.
Review the location of the generator,
and place it in a well-ventilated
outdoor location (see page 23).
When the engine is stopped
automatically by CO-MINDER, press
the CO-MINDER reset button to restart
the engine (see page 39).
Possible Cause Correction
CO sensor malfunction. If the engine cannot be started and the
CO ALARM indicator flashes, even if the
location of the generator has changed,
there may be a CO-MINDER
malfunction. Consult an authorized
Honda Power Equipment dealer.
CO sensor may have reached the end
of its useful lifespan (see page 24).
Consult an authorized Honda Power
Equipment dealer.
Possible Cause Correction
CO sensor may reach the end of its
useful lifespan (see page 24).
Consult an authorized Honda Power
Equipment dealer for replacement.

69
TECHNICAL INFORMATION
SERIAL NUMBER LOCATION
Record the frame serial number and date purchased in the spaces below. You
will need this information when ordering parts and when making technical or
warranty inquiries.
Frame serial number:
Date purchased:
FRAME SERIAL NUMBER

TECHNICAL INFORMATION
70
CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION
At high altitude, the standard carburetor air-fuel mixture will be too rich.
Performance will decrease, and fuel consumption will increase. A very rich
mixture will also foul the spark plug and cause hard starting. Operation at an
altitude that differs from that at which this engine was certified, for extended
periods of time, may increase emissions.
High altitude performance can be improved by specific modifications to the
carburetor. If you always operate your generator at altitudes above 2,000 feet
(610 meters), have your authorized Honda servicing dealer perform this
carburetor modification. This engine, when operated at high altitude with the
carburetor modifications for high altitude use, will meet each emission standard
throughout its useful life.
Even with carburetor modification, engine horsepower will decrease about
3.5% for each 1,000-foot (300-meter) increase in altitude. The effect of altitude
on horsepower will be greater than this if no carburetor modification is made.
When the carburetor has been modified for high altitude operation, the air/fuel
mixture will be too lean for low altitude use. Operation at altitudes below 2,000 feet
(610 meters) with a modified carburetor may cause the engine to overheat and
result in serious engine damage. For use at low altitudes, have your servicing dealer
return the carburetor to original factory specifications.

TECHNICAL INFORMATION
71
EMISSION CONTROL SYSTEM INFORMATION
Source of Emissions
The combustion process produces carbon monoxide, oxides of nitrogen, and
hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very
important because, under certain conditions, they react to form photochemical
smog when subjected to sunlight. Carbon monoxide does not react in the same
way, but it is toxic.
Honda utilizes appropriate air/fuel ratios and other emissions control systems to
reduce the emissions of carbon monoxide, oxides of nitrogen, and
hydrocarbons.
Additionally, Honda fuel systems utilize components and control technologies
to reduce evaporative emissions.
The U.S. and California Clean Air Acts, and Environment and Climate
Change Canada (ECCC)
U.S. EPA, California and Canadian regulations require all manufacturers to
furnish written instructions describing the operation and maintenance of
emission control systems.
The following instructions and procedures must be followed in order to keep
the emissions from your Honda engine within the emission standards.
Tampering and Altering
Tampering is a violation of federal and California law.
Tampering with or altering the emission control system may increase emissions
beyond the legal limit. Among those acts that constitute tampering are:
• Removal or alteration of any part of intake, fuel, or exhaust systems.
• Alterations that would cause the engine to operate outside its design
parameters.

TECHNICAL INFORMATION
72
Problems That May Affect Emissions
If you are aware of any of the following symptoms, have your engine inspected
and repaired by your authorized Honda Power Equipment dealer.
• Hard starting or stalling after starting.
•Rough idle.
• Misfiring or backfiring under load.
• Afterburning (backfiring).
• Black exhaust smoke or high fuel consumption.
Replacement Parts
The emissions control systems on your new Honda engine were designed, built,
and certified to conform with EPA, California (models certified for sale in
California only), and Canadian emissions regulations. We recommend the use of
Honda Genuine parts whenever you have maintenance done. These original
design replacement parts are manufactured to the same standards as the
original parts, so you can be confident of their performance. Honda cannot
deny coverage under the emission warranty solely for the use of non-Honda
replacement parts or service performed at a location other than an authorized
Honda dealership; you may use comparable EPA certified parts, and have
service performed at non-Honda locations. However, the use of replacement
parts that are not of the original design and quality may impair the effectiveness
of your emissions control system.
A manufacturer of an aftermarket part assumes the responsibility that the part
will not adversely affect emissions performance. The manufacturer or rebuilder
of the part must certify that use of the part will not result in a failure of the
engine to comply with emissions regulations.
Maintenance
As the power equipment engine owner, you are responsible for completing all
required maintenance listed in your owner's manual. Honda recommends that
you retain all receipts covering maintenance on your power equipment engine,
but Honda cannot deny warranty coverage solely for the lack of receipts or for
your failure to ensure that all scheduled maintenance has been completed.
Follow the "MAINTENANCE SCHEDULE" on page 53.
Remember that this schedule is based on the assumption that your Honda
engine product will be used for its designed purpose. Sustained high-load or
high-temperature operation, or use in dusty conditions, will require more
frequent service.

TECHNICAL INFORMATION
73
Air Index
(Models certified for sale in California)
An Air Index Information label is applied to engines certified to an emission
durability time period in accordance with the requirements of the California Air
Resources Board.
The bar graph is intended to provide you, our customer, the ability to compare
the emissions performance of available engines. The lower the Air Index, the
less pollution.
The durability description is intended to provide you with information relating
to the engine’s emission durability period. The descriptive term indicates the
useful life period for the engine’s emission control system. See your "Emission
Control System Warranty" (see page 84) for additional information.
Descriptive Term Applicable to Emission Durability Period
Moderate 50 hours (0–80 cc, inclusive)
125 hours (greater than 80 cc)
Intermediate 125 hours (0–80 cc, inclusive)
250 hours (greater than 80 cc)
Extended 300 hours (0–80 cc, inclusive)
500 hours (greater than 80 cc)
1,000 hours (225 cc and greater)

TECHNICAL INFORMATION
74
SPECIFICATIONS
Dimensions
Engine
Generator
Model EU1000iT1
Description code EAAT
Length 17.8 in (451 mm)
Width 9.5 in (242 mm)
Height 14.9 in (379 mm)
Dry mass [weight] 29.5 lbs (13.4 kg)
Model GXH50T
Engine type 4-stroke, overhead valve, single cylinder
Displacement
[Bore × Stroke]
3.01 cu-in (49.4 cm
3
)
[1.65 × 1.42 in (41.8 × 36.0 mm)]
Compression ratio 8.0:1
Engine speed 5,500 – 6,000 rpm
(with Eco Throttle switch OFF)
Cooling system Forced air
Ignition system Full transistor
Engine oil capacity 8 oz (0.25 L)
Fuel tank capacity 0.55 US gal (2.1 L)
Spark plug LR4C-E (NGK)
Model EU1000iT1
Type AG type
AC
output
Rated Voltage 120 V
Rated Frequency 60 Hz
Rated Current 7.5 A
Rated Output 0.9 kVA
Maximum Output 1.0 kVA

TECHNICAL INFORMATION
75
Tuneup Specifications
Specifications are subject to change without notice.
ITEM SPECIFICATION MAINTENANCE
Spark plug gap 0.024 – 0.028 in
(0.6 – 0.7 mm)
Refer to page 56.
Valve clearance (cold) IN: 0.08 ± 0.02 mm
EX: 0.11 ± 0.02 mm
See your authorized
Honda Power
Equipment dealer.
Other specifications No other adjustments needed.

TECHNICAL INFORMATION
76
WIRING DIAGRAM
R
RR
R/W
R/Y
G/R
G/Bl
Bu
Y
R
W
Bl/Bu
Gr
Br
P
Bu
W
R
Y
Bl
Y
Bl
Bl/BuBl/Bu
Bu
G
Br
Br
Bu
G
Br
Br
P
Gr
Br
R
Bu
W
Br
R
Bu
W
Bl/Bu
Gr
Br
P
G
G
R
R
R
R
W
Y
Bu
G
B
G
G
G
BB
Bu
YY
G
B
R/W
R/Y
R/W
G/R
G/Bl
Bl/Bu
Y
G
Bl
Bu
GENERATOR BLOCK
CONTROL PANEL BLOCK
THROT CONTL MOTOR
FRM EARTH
ENG STOP SW
OIL LEV
SW
PULSER
COIL
ENG EARTH
IGN COIL
ENGINE BLOCK
S-PLUG
MAIN. W.
COM
ECO THROTTLE SW
ENG STOP SW
OFF
ON
CSW
PL
OL
OA
IND (+)
PL
OL
OIL
ALERT
UNIT
FULL-Tr
UNIT
LS
AC OUT 1
AC OUT 2
GND
ING
EX
PC
ECO THROTTLE SW
EX. W.
SUB. W.
(INV)
SUB. W.
(CO)
COMPOSITE
SOCKET
AC RECEPTACLE
15A-125V
SPARK UNIT
(WITH INDICATOR)
IG
OFF
ON
E
SUB 2
MAIN 1
MAIN 2
MAIN 3
SUN 1
INVERTER
/B
/A
B
A
OL (RED)
PL (GREEN)
N. C.
N. C.
N. C.
N. C.
ECO SW
COM
Bu
G
R
W
Bl BLACK
YELLOW
BROWNBr
ORANGEO
LIGHT BLUELb
LIGHT GREENLg
PINKP
GRAYGr
BLUE
GREEN
RED
WHITE
V BEIGEBeVIOLET
Y
COLOR COMB: GROUND/MARKING
CO UNIT and
INDICATOR UNIT

77
CONSUMER INFORMATION
DEALER LOCATOR INFORMATION
To find an authorized Honda Servicing Dealer anywhere in the United States:
Visit our website:
http://powerequipment.honda.com/dealer-locator
Honda PUBLICATIONS
Shop Manual
This manual covers complete maintenance and overhaul procedures.
It is intended to be used by a skilled technician.
Available through your Honda dealer or visit
http://powerequipment.honda.com/support/shop-manuals
Parts Catalog
This manual provides complete, illustrated parts lists for your generator. Visit
peparts.honda.com for free online access to the parts catalog. It is also available
for purchase in paper form through your Honda dealer.
Accessories Catalog
Your authorized Honda Power Equipment dealer offers a wide selection of
accessories (optional equipment) to make your generator even more useful.
Visit http://powerequipment.honda.com/generators/accessories and click on
See all generator accessories and Welders to see the entire catalog of
accessories.

CONSUMER INFORMATION
78
CUSTOMER SERVICE INFORMATION
Honda Power Equipment dealership personnel are trained professionals. They
should be able to answer any question you may have. If you encounter a
problem that your dealer does not solve to your satisfaction, please discuss it
with the dealership’s management.
The Service Manager or General Manager can help. Almost all problems are
solved in this way.
If you are dissatisfied with the decision made by the dealership’s management,
contact the Honda Power Equipment Customer Relations Office. You can write
to:
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Or telephone: (770) 497-6400
1-888-888-3139 (toll free)
M-F 9:00am - 7:30pm ET
When you write or call, please give us this information:
• Model and serial numbers (see page 69)
• Name of the dealer who sold the generator to you
• Name and address of the dealer who services your generator
• Date of purchase
• Your name, address, and telephone number
• A detailed description of the problem

CONSUMER INFORMATION
79
Distributor’s Limited Warranty
This warranty is limited to the following Honda products when distributed by
American Honda Motor Co., Inc., Power Sports and Products Division, 4900
Marconi Drive, Alpharetta, Georgia 30005. The following warranty applies to
products manufactured on or after April 1, 2023.
(1) Length of Warranty: Batteries supplied with applicable products as
standard, original equipment are covered by this warranty for a period of 12
months (private residential) or 3 months (commercial/rental/institutional
use) from the date of original retail product purchase.
(2) Private residential: Used in maintaining owner’s primary and/or secondary
residence. Any other use, including but not limited to informal “for hire” use,
is considered commercial/rental/institutional use.
To Qualify for This Warranty:
The product must be purchased in the United States, Puerto Rico, or the U.S.
Virgin Islands from American Honda or a dealer authorized by American Honda
to sell those products. This warranty applies to first retail purchaser and each
subsequent owner during the applicable warranty time period, unless noted
otherwise.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any part that is proven to be
defective in material or workmanship under normal use during the applicable
warranty time period. Warranty repairs and replacements will be made without
charge for parts or labor. Anything replaced under warranty becomes the
property of American Honda Motor Co., Inc. All parts replaced under warranty
will be considered as part of the original product, and any warranty on those
parts will expire coincident with the original product warranty.
PRODUCTS COVERED
BY THIS WARRANTY:
LENGTH OF WARRANTY: (1)
(FROM DATE OF ORIGINAL RETAIL PURCHASE)
PRIVATE
RESIDENTIAL (2)
COMMERCIAL/
RENTAL/INSTITUTIONAL
Generators 36 months 12 months
The Parts, Accessories, and Apparel warranty is on page 82

CONSUMER INFORMATION
80
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment product,
accessory, replacement part, apparel, or the power equipment on which the
accessory or replacement part is installed, and proof of purchase to any Honda
Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin
Islands who is authorized to sell and/or service that product, during the dealer’s
normal business hours. To locate a dealer near you, visit our web site at http://
powerequipment.honda.com and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved;
normally this will resolve the problem. However, if you should require further
assistance, write or call the Power Equipment Customer Relations Department
of American Honda Motor Co., Inc. at the following address:
American Honda Motor Co., Inc.
Power Equipment Customer Relations Dept.
4900 Marconi Drive
Alpharetta, GA 30005-8847 Telephone: (770) 497-6400

CONSUMER INFORMATION
81
Exclusions:
1. Any damage or deterioration resulting from the following:
– Neglect of the periodic maintenance as specified in the product owner’s
manual
– Improper repair or maintenance
– Operating methods other than those indicated in the product owner’s
manual
– Increasing engine speed beyond factory specification
– The use of non-genuine Honda parts, accessories, lubricants, and fluids
other than those approved by Honda
– Exposure of the product to soot and smoke, chemical agents, bird
droppings, sea water, salt, or other corrosive environments
– Collision, fuel contamination or deterioration, neglect, unauthorized
alteration, misuse, incorporation or use of unsuitable attachments or parts
– Normal wear and tear (including, but not limited to, normal fading of
painted or plated surfaces, sheet peeling, and other natural deterioration)
2. Consumable parts: Honda does not warrant parts deterioration due to
normal wear and tear. The following parts are not covered by this warranty
unless they are needed during another repair covered under this warranty:
spark plug, fuel filter, air cleaner element, clutch disc, tire, wheel bearing,
recoil starter rope, cable, belt, cutter blade, oil, and grease.
3. Cleaning, adjustment, and normal periodic maintenance work (carburetor
cleaning, engine oil draining, blade sharpening, belt and cable adjustments).
4. Any product that has ever been declared a total loss or sold for salvage by a
financial institution or insurer.
5. Auger and paddle assemblies, skid shoes, and scraper bars of snow throwers/
snow blowers, tiller tines of roto-tillers, and mower blades and mower deck
housings are specifically not warranted against impact damage including,
but not limited to, abrasive damage.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the
product, transportation, commercial loss, or any other incidental or
consequential damage. Any implied warranties are limited to the duration of
this written limited warranty. Some states do not allow limitations on how long
an implied warranty lasts and/or do not allow the exclusion or limitation of
incidental or consequential damages, therefore the above exclusions and
limitations may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights, which vary from state to state.

CONSUMER INFORMATION
82
Honda Parts, Accessories, and Apparel
This warranty is limited to Honda Power Equipment parts, accessories, and
apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi
Drive, Alpharetta, Georgia 30005-8847.
To Qualify for This Warranty:
1. The parts, accessories, or apparel must be purchased from American Honda
or a dealer authorized by American Honda to sell those products in the
United States, Puerto Rico, and the U.S. Virgin Islands. Parts and accessories
must be purchased for installation on original Honda equipment or engines
to be eligible for warranty coverage.
Installing parts and accessories on non-Honda products or engines voids this
warranty.
2. You must be the first retail purchaser. This warranty is not transferable to
subsequent owners.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any Honda Power
Equipment parts, accessories, or apparel that are proven to be defective in
material or workmanship under normal use during the applicable warranty time
period. Anything replaced under warranty becomes the property of American
Honda Motor Co., Inc. The warranty on all parts, accessories, and apparel
replaced under warranty will expire coincident with the original warranty on the
replaced parts, accessories, or apparel.
Parts and accessories installed by a dealer who is authorized by American
Honda to sell them will be repaired or replaced under warranty without charge
for parts or labor. If installed by anyone else, parts and accessories will be
repaired or replaced under warranty without charge for parts, but any labor
charges will be the responsibility of the purchaser.
Apparel will be repaired or replaced under warranty without any charge.
PRODUCTS COVERED
BY WARRANTY:
LENGTH OF WARRANTY:
(FROM DATE OF ORIGINAL RETAIL PURCHASE)
PRIVATE
RESIDENTIAL
COMMERCIAL/
RENTAL/INSTITUTIONAL
Parts 6 months 3 months
Batteries 6 months 3 months
Accessories 12 months 3 months
Apparel 6 months 3 months

CONSUMER INFORMATION
83
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment part, accessory, or
apparel, or the Honda Power Equipment on which the accessory or part is
installed, and proof of purchase to any Honda Power Equipment dealer in the
United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell
that product, during the dealer’s normal business hours.
To locate a dealer near you, go to our web site at http://PowerEquipment.Honda.com
and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved; normally this
will resolve the problem. However, if you should require further assistance,
write or call the Power Equipment Customer Relations Department of American
Honda Motor Co., Inc. Refer to page 80 for contact information.
Exclusions:
This warranty does not extend to parts, accessories, or apparel affected or
damaged by collision, normal wear, use in an application for which the product
was not designed, or any other misuse, neglect, incorporation or use of
unsuitable attachments or parts, unauthorized alteration, improper installation,
or any causes other than defects in material or workmanship of the product.
Installing parts and accessories on non-Honda products or engines voids this
warranty.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the
product, or the power equipment on which the product is installed,
transportation, commercial loss, or any other incidental or consequential
damage. Any implied warranties are limited to the duration of this written
warranty. Some states do not allow limitations on how long an implied warranty
lasts and/or do not allow the exclusion or limitation of incidental or
consequential damages, so the above exclusions and limitations may not apply
to you.
This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state.

CONSUMER INFORMATION
84
Emission Control System Warranty
Your new Honda Power Equipment engine complies with the U.S. EPA,
Environment Canada, and State of California (models certified for sale in
California only) emission regulations. American Honda Motor Co., Inc. provides
the emission warranty coverage for engines in the United States and its
territories. Honda Canada Inc. provides the emission warranty for engines in the
13 provinces and territories of Canada. In the remainder of this Emission Control
System Warranty, American Honda Motor Co., Inc. and Honda Canada Inc. will
be referred to as Honda.
CALIFORNIA EXHAUST AND EVAPORATIVE EMISSIONS CONTROL
WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS
The California Air Resources Board and Honda are pleased to explain the
exhaust and evaporative emissions (“emissions”) control system warranty on
your 2023 and later Honda Power Equipment engine. In California, new
equipment that use small off-road engines must be designed, built, and
equipped to meet the State's stringent anti-smog standards. Honda must
warrant the emissions control system on your power equipment engine for the
periods of time listed below provided there has been no abuse, neglect, or
improper maintenance of your small off-road engine or equipment leading to
the failure of the emissions control system.
Your emissions control system may include parts such as the carburetor or
fuel-injection system, the ignition system, catalytic converter, fuel tanks, fuel
lines (for liquid fuel and fuel vapors), fuel caps, valves, canisters, filters, clamps
and other associated components. Also included may be hoses, belts,
connectors, and other emission-related assemblies (see page 88 for additional
covered parts).
Where a warrantable condition exists, Honda will repair your power equipment
engine at no cost to you including diagnosis, parts and labor.
MANUFACTURER'S WARRANTY COVERAGE:
The exhaust and evaporative emissions control system on your Honda power
equipment engine is warranted for two years. If any emissions-related part on
your Honda power equipment engine is defective, the part will be repaired or
replaced by Honda.

CONSUMER INFORMATION
85
OWNER'S WARRANTY RESPONSIBILITY:
• As the power equipment engine owner, you are responsible for the
performance of the required maintenance listed in your owner's manual.
Honda recommends that you retain all receipts covering maintenance on
your power equipment engine, but Honda cannot deny warranty coverage
solely for the lack of receipts or for your failure to ensure the performance of
all scheduled maintenance.
• As the power equipment engine owner, you should however be aware that
Honda may deny you warranty coverage if your power equipment engine or a
part has failed due to abuse, neglect, improper maintenance, or unapproved
modifications.
• You are responsible for presenting your power equipment engine to a Honda
Power Equipment servicing dealer as soon as the problem exists. The
warranty repairs shall be completed in a reasonable amount of time, not to
exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities,
you should contact the Honda office in your region:
American Honda Motor Co., Inc.
Power Equipment Customer
Relations
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
@ahm.honda.com
or
Honda Canada Inc.
Power Equipment Customer
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
Telephone: (888) 946-6329

CONSUMER INFORMATION
86
YOUR WARRANTY RIGHTS AND OBLIGATIONS
Other States, U.S. territories, and Canada:
In other areas of the United States and in Canada, your engine must be
designed, built, and equipped to meet the U.S. EPA and Environment Canada
emission standards for spark-ignited engines at or below 19 kilowatts.
Specific Honda products that do not meet the California emissions regulations
can be identified by a “California: Not for sale or use” or “California: Only for use
in Farming or Construction Equipment” decal.
All of the United States and Canada:
The exhaust and evaporative emissions control system on your Honda power
equipment engine sold in the United States and Canada is warranted for two
years from the date of delivery to the ultimate purchaser or the length of the
Honda Distributor’s Limited Warranty, whichever is longer. This warranty is
transferable to each subsequent purchaser for the duration of the warranty
period.
If any emissions-related part on your Honda power equipment engine is
defective, the part will be repaired or replaced by Honda. All defective parts
replaced under this warranty become the property of Honda. Only Honda
approved replacement parts may be used in the performance of any warranty
repairs and must be provided without charge to the owner. A list of warranted
parts is on the reverse side of this warranty statement. All emission related parts
are under warranty for the remainder of the warranty period. Normal
maintenance items, such as spark plugs and filters, that are on the warranted
parts list are warranted up to their required replacement interval only.
Honda will also replace other engine components damaged by a failure of any
warranted part during the warranty period. Honda cannot deny coverage under
the emission warranty solely for use of non-Honda replacement parts or service
performed at a location other than an authorized Honda dealership; however,
use of a part that is not functionally identical to the original equipment part in
any respect that may in any way affect emissions (including durability) could
result in denial of coverage. If such a non-Honda replacement part is used in the
repair or maintenance of your engine, and an authorized Honda dealer
determines it is defective or causes a failure of a warranted part, your claim for
repair of your engine may be denied. If the part in question is not related to the
reason your engine requires repair, your claim will not be denied.

CONSUMER INFORMATION
87
TO OBTAIN WARRANTY SERVICE:
You must, at your own expense, take your Honda Power Equipment engine or
the product on which it is installed, along with your sales registration card or
other proof of original purchase date, to any Honda Power Equipment dealer
who is authorized by Honda to sell and service that Honda product during their
normal business hours. Claims for repair or adjustment found to be caused
solely by defects in material or workmanship will not be denied because the
engine was not properly maintained and used.
If you are unable to obtain emission warranty service or are dissatisfied with the
warranty service you received, contact the owner of the dealership involved.
Normally this should resolve your problem. However, if you require further
assistance, contact the Honda office in your region:
EXCLUSIONS:
Failures other than those resulting from defects in material or workmanship are
not covered by this warranty. This warranty does not extend to emission control
systems or parts that are affected or damaged by owner abuse, neglect,
improper maintenance, or unapproved modifications.
This warranty does not cover replacement of expendable maintenance items
made in connection with required maintenance service after the item's first
scheduled replacement as listed in the maintenance section of the product
owner's manual, such as: spark plugs and filters.
American Honda Motor Co., Inc.
Power Equipment Customer
Relations
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
@ahm.honda.com
or
Honda Canada Inc.
Power Equipment Customer
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
Telephone: (888) 946-6329

CONSUMER INFORMATION
88
DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION OF IMPLIED
WARRANTIES:
American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any
responsibility for incidental or consequential damages such as loss of time or
the use of the power equipment, or any commercial loss due to the failure of the
equipment; and any implied warranties are limited to the duration of this
written warranty. This warranty is applicable only where the California, U.S. EPA,
or Environment Canada emission control system warranty regulation is in effect.
EMISSION CONTROL SYSTEM WARRANTY PARTS:
*Covered up to the first required replacement only.
See the "MAINTENANCE SCHEDULE" on page 53.
SYSTEMS COVERED
BY THIS WARRANTY:
PARTS
DESCRIPTION:
Fuel Metering Carburetor assembly (includes starting enrichment
system), Oxygen sensor, Throttle body, Engine
temperature sensor, Engine control module, Fuel
injector, Fuel regulator, Intake manifold
Evaporative Fuel tank, Fuel cap, Fuel lines (for liquid and fuel
vapors), Carbon canister, Canister mounting
brackets, Fuel line fittings, Fuel strainer, Fuel valve,
Fuel pump, Fuel hose joint, Canister purge port
connector
Exhaust Catalyst, Exhaust pipe, Muffler (with catalyst),
Exhaust manifold
Air Induction Air cleaner case, Air cleaner element*
Ignition Flywheel comp., Flywheel magneto, Ignition pulse
generator, Crankshaft position sensor, Power coil,
Ignition coil assembly, Ignition control module,
Spark plug cap, Spark plug*
Crankcase Emission
Control
Crankcase breather tube, Breather valve assembly,
Oil filler cap
Miscellaneous Parts Tubing, fittings, seals, gaskets, and clamps
associated with these listed systems.

CONSUMER INFORMATION
89
REGISTRATION
Please Register Your Generator
If your dealer did not collect registration information from you, please take a
few minutes and register your purchase with Honda. This allows us to contact
you with any important updates regarding your generator. Please note
registration is not required to obtain warranty service. You can register your
generator by visiting the Honda Power Equipment website,
http://powerequipment.honda.com/support and click on Product Registration.
Your information will remain confidential. It will not be released to any other
company or organization.

90
INDEX
A
AC Appliance and Power Cord........................................................................................ 29
AC Applications.................................................................................................................... 42
AC OPERATION ..................................................................................................................... 40
AC Parallel Operation Applications............................................................................... 45
AC PARALLEL OPERATION................................................................................................ 43
AIR CLEANER SERVICE ........................................................................................................ 55
AIR FILTER CHECK ................................................................................................................ 32
Air Index .................................................................................................................................. 73
ARE YOU READY TO GET STARTED? .............................................................................. 28
B
BEFORE OPERATION ........................................................................................................... 28
C
Carbon Monoxide Hazards................................................................................................. 7
CARBURETOR MODIFICATION FOR HIGH ALTITUDE OPERATION...................... 70
Check the Engine................................................................................................................. 29
Choke Lever ........................................................................................................................... 21
Cleaning .................................................................................................................................. 60
CO-MINDER (CO Shut-off System) ................................................................................. 23
COMPONENT & CONTROL LOCATIONS ....................................................................... 18
Connections to a Building’s Electrical System........................................................... 49
CONSUMER INFORMATION.............................................................................................. 77
CONTROLS & FEATURES .................................................................................................... 18
CONTROLS.............................................................................................................................. 20
CUSTOMER SERVICE INFORMATION ............................................................................. 78
D
DEALER LOCATOR INFORMATION................................................................................. 77
Distributor’s Limited Warranty .......................................................................................79
E
Eco Throttle
®
Switch............................................................................................................ 22
ECO THROTTLE
®
SYSTEM................................................................................................... 48
Electric Shock Hazards ......................................................................................................... 8
EMISSION CONTROL SYSTEM INFORMATION............................................................ 71
Emission Control System Warranty ...............................................................................84
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR
FLASHING .......................................................................................................................... 68

91
INDEX
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING................................................................................................... 68
Engine Cylinder .................................................................................................................... 63
ENGINE LACKS POWER....................................................................................................... 67
ENGINE OIL CHANGE .......................................................................................................... 53
ENGINE OIL LEVEL CHECK ................................................................................................. 30
ENGINE OIL RECOMMENDATIONS................................................................................. 13
ENGINE OIL...................................................................................................................... 12, 63
Engine Switch........................................................................................................................ 20
ENGINE WILL NOT START .................................................................................................. 66
F
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING
THE ENGINE....................................................................................................................... 68
FEATURES ............................................................................................................................... 26
Fire and Burn Hazards .......................................................................................................... 8
Foam Air Filter Cleaning.................................................................................................... 55
Fuel Filler Cap Vent Lever ................................................................................................. 21
FUEL RECOMMENDATIONS.............................................................................................. 17
FUEL................................................................................................................................... 14, 60
G
GENERATOR SAFETY............................................................................................................. 6
Ground Terminal.................................................................................................................. 27
H
Honda PUBLICATIONS........................................................................................................ 77
HOW TO RESTART WHEN STOPPED BY CO-MINDER (CO SHUT-OFF SYSTEM)
............................................................................................................................................... 39
I
IMPORTANT SAFETY INFORMATION............................................................................... 6
INITIAL USE INSTRUCTIONS.............................................................................................. 12
INTRODUCTION ......................................................................................................................1
IS YOUR GENERATOR READY TO GO?........................................................................... 28
K
Knowledge ............................................................................................................................. 28
M
MAINTENANCE SAFETY ..................................................................................................... 52

92
INDEX
MAINTENANCE SCHEDULE............................................................................................... 53
N
NO POWER AT THE AC RECEPTACLES .......................................................................... 67
O
Oil Alert
®
/Check Indicator................................................................................................. 27
OPERATION ............................................................................................................................ 34
Operator Responsibility....................................................................................................... 6
Overload Alarm (Indicator)............................................................................................... 26
Output Indicator .................................................................................................................. 26
P
Parallel Operation Outlets ................................................................................................ 25
Please Register Your Generator...................................................................................... 89
Q
QUICK REFERENCE INFORMATION .................................................. inside back cover
R
Refuel With Care..................................................................................................................... 9
REGISTRATION ...................................................................................................................... 89
REMOVAL FROM STORAGE............................................................................................... 64
S
SAFE OPERATING PRECAUTIONS ................................................................................... 33
SAFETY LABEL LOCATIONS............................................................................................... 10
Safety Precautions............................................................................................................... 52
SERIAL NUMBER LOCATION............................................................................................. 69
SERVICING YOUR GENERATOR........................................................................................ 51
SPARK ARRESTER SERVICE ................................................................................................ 58
SPARK PLUG SERVICE ......................................................................................................... 56
Special Requirements......................................................................................................... 50
SPECIFICATIONS................................................................................................................... 74
STANDBY POWER................................................................................................................. 49
Starter Grip............................................................................................................................. 20
STARTING THE ENGINE ...................................................................................................... 34
STOPPING THE ENGINE...................................................................................................... 37
STORAGE PRECAUTIONS................................................................................................... 64
STORAGE PREPARATION ................................................................................................... 60
STORAGE................................................................................................................................. 60

93
INDEX
System Ground..................................................................................................................... 49
T
TAKING CARE OF UNEXPECTED PROBLEMS............................................................... 66
TECHNICAL INFORMATION .............................................................................................. 69
THE IMPORTANCE OF MAINTENANCE.......................................................................... 51
TRANSPORTING .................................................................................................................... 65
V
Vehicles and Transportation Hazards............................................................................. 9
W
WIRING DIAGRAM................................................................................................................ 76

94
MEMO

95
MEMO

96
MEMO

QUICK REFERENCE INFORMATION
Fuel Type Regular unleaded gasoline with an
ethanol content of no more than 10%
and a pump octane rating of 86 or
higher
Engine Oil Type SAE 10W-30, API SJ or later (or
equivalent), for general use
(see page 13)
Maximum oil capacity: 8 oz (0.25 L)
Spark Plug Type NGK: LR4C-E
Electrode Gap 0.024–0.028 in (0.6–0.7 mm)
Maintenance Before each use Check engine oil level.
Check air filter.
First 10 hours Change engine oil.
Subsequent See "MAINTENANCE SCHEDULE"
(see page 53)

Printed in Thailand
GENERATOR
’Owner s Manual
H i
FMAH
英
PANTONE
186C
K
背幅4.6mm
EU1000i
See page 12 for Initial Use Instructions
2023 Honda Motor Co., Ltd. -All Rights Reserved
C
EU1000i
31Z40614
00X31-Z40-6140