CE LINK 300W PRO Portable Power Station

Product's Documents

Below are documents related to this product, you can read online or download:
300W PRO photo

Users Manual

This is the main product document for model 300W PRO. Additionally, the document applies to other CE LINK models: 300W

The file format is pdf, 12 pages, you can download this manual here .

background
���W Portable Power Station
User Manual
This manual is a general version. If the purchased unit does not support wireless charging, please disregard the related descriptions.
background
Content
�. Maintenance
��
�. What's in the box
��
�. Error messages & solutions
��
�. FAQs (Frequently Asked Questions)
��
�.� Product overview
�.� LCD screen
�.� Use
�.� AC charging
�.� Car charging
�.�
Wireless Charging (Optional)
��
��
�.�
PV charging
��
�. Guideline for users
�. Safety guidelines
�.� Warning
�.� Disposal
�. Parameters
�.� EPS function
��
�. Disclaimer
��
�. Parameters
Output
Inverter mode
AC socket*�
pure sine-wave, total ���W (peak ���W), ���-���V~, ��Hz/��Hz, �.�A
Bypass mode
���-���V~, ��Hz/��Hz, ���W Max., �.�A
(UK/EU/FR/AU/ZA)
(US)
USB-A�
USB-C�/C�
USB-C�
Car charger
Wireless Charger (Optional)
��W Max.
��.�V ��A, ���W Max.
�V �.�A, ��W Max.
�/�/��/��V �A, ��V �.��A, ��W Max.
General
Net weight
Dimension
≈�.�kg (≈�.��lbs)
���x���x���mm (�.�*�.�*�.�in)
Battery capacity
���W h ��.�V , ��Ah
Input
AC input power
AC input voltage
���-���V~, ��Hz/��Hz
(UK/EU/FR/AU/ZA)
Inverter mode
AC socket*�
pure sine-wave, total ���W (peak ���W), ���-���V~, ��Hz, �A
���-���V~, ��Hz, ���W Max., �A
�V �A, �V �.��A, ��W Max.
���W Max., �A
AC input power
AC input voltage
���-���V~, ��Hz
(US)
���W Max., �A
Bypass mode
* Bypass mode: the output AC power comes from the grid, not the battery.
* Inverter mode: the output AC power comes from the battery, not the grid.
�.� P-Boost function
��
background
PV charge
Car charging input
��V battery supported, �A by default
���W Max., ��-��V �A
PV charging input
��W Max.
Car charging input
��W Max.
Input charging
AC+PV charging power
���W Max.
AC charging power
���W Max.
*Whether the product can be charged or discharged is subject to the actual battery pack temperature.
*Test conditions: ��%DOD, �.�C charge & discharge at +��℃±�°C, ��%SOH.
Battery
Cell Type
Life cycle
Protection type
lithium iron phosphate battery (LiFePO
)
���� cycles
�. Safety guidelines
�.� Warning
over temperature protection, low temperature protection,
over discharge protection, over charge protection, over load
protection, short circuit protection, over current protection
�.Do not place this product near heat sources while it is operating, such as open flames or heaters.
�.Keep this product away from all liquids. Do not immerse it in water or allow it to get wet. Never use the product in the rain or in
humid environments.
�.Do not use this product in environments with strong static electricity or strong magnetic fields.
�.Do not disassemble or puncture this product in any way using sharp objects.
�.Do not short-circuit the product using wires or other metal objects.
�.Do not step on, sit on, or climb on the product.
�.Do not use any parts or accessories not provided by the manufacturer. For replacements, please refer to official sales channels.
�.Use this product strictly within the operating temperature range specified in this manual. Excessive heat may cause the battery
to catch fire or even explode; excessive cold may severely reduce product performance and affect normal use.
�.Do not place heavy objects on top of this product.
��.Do not forcibly block the fan while the product is in use. Avoid using the product in poorly ventilated or dusty environments.
��.Avoid impacts, drops, or strong vibrations. If the product experiences significant external impact, immediately power it off and
stop using it. Secure the product during transport to prevent shock or collision.
��.If the product is accidentally dropped into water, place it in a safe and open area, and stay away until it is completely dry. Do
not reuse the product once dried. Dispose of it properly as described in Section �.� (Disposal). If the product catches fire, use
firefighting equipment in the following recommended order: water or mist, sand, fire blanket, dry powder, or CO
extinguisher.
��.If there is dirt on the products ports, wipe it off with a dry cloth.
��.Place the product securely to prevent it from tipping over. In case of severe damage caused by tipping, immediately shut it
down, place the battery in an open area away from flammable materials and people, and dispose of it in accordance with local
laws and regulations.
��.Keep the product out of reach of children and pets.
��.Store the product in a dry, well-ventilated place.
��.When using the product in humid environments (e.g., near the sea or water), it is recommended to use it with a moisture-proof
bag to avoid water ingress. If water enters the product, do not reuse or power it on.
��.This product is not recommended for powering life-support or safety-critical medical devices, including but not limited to
hospital-grade CPAP (Continuous Positive Airway Pressure) machines and ECMO (Extracorporeal Membrane Oxygenation)
systems. However, home-use CPAP machines for general household environments may be used, as they typically do not require
constant professional monitoring. Please follow medical advice and consult the device manufacturer regarding usage
limitations. For general medical equipment, always monitor battery levels to avoid power depletion.
��.Power supplies will inevitably generate electromagnetic fields when it is in use, which might affect the implantable medical
device or normal operation of personal medical device, such as pacemaker devices, cochlear implants, hearing AlDs,
defibrillators, etc. lf any of these medical devices are used, please consult the manufacturer about the restrictions on the use to
ensure that power station is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants,
hearing AlDs, defibrillators, etc.
Operating temperature
Discharge temperature range
Charge temperature range
-��℃~��℃ (-�°F~���°F)
�℃~��℃ (��°F~���°F)
Optimal operating temperature
Storage ambient temperature
��℃~��℃ (��°F~��°F)
-��℃~��℃(��℃~��℃ preferred) [ -�°F~���°F(��°F~��°F preferred)]
background
�.� Disposal
�.� Product overview
�. Guideline for users
�.If conditions permit, please ensure the battery is fully discharged before placing the product in a designated battery recycling bin.
Power station contains a battery, which is classified as hazardous chemical waste and must not be disposed of in regular trash bins.
For more details, please follow local laws and regulations regarding battery recycling and disposal.
�.If the battery cannot be fully discharged due to a product malfunction, do not place it directly into a recycling bin. Instead, contact
a certified battery recycling company for proper handling.
�.If the battery is over-discharged and cannot be restarted, please treat it as waste and dispose of it accordingly.
��.When the power station is connected to a refrigerator load in normal mode, the power fluctuation characteristics of the
refrigerator may cause the power station to shut down automatically. For refrigerators storing medicines, vaccines, or other
high-value items, it is recommended to long-press the LED button to activate the "Never Shutdown" mode when connecting to
the power station, ensuring continuous power supply. Meanwhile, the user should monitor the power station's battery level to
avoid unexpected power loss.
��.Do not place any items on top of the product while moving it by pushing or pulling.
Car Output Port
DC/Wireless Output
Power Button
LED Light button
LED Light
LCD (Liquid
Crystal Display)
Wireless Charger
AC Output
Power Button
Strap
AC Output Sockets
USB-C Output Ports
x
ON/OFF button
FR
ZA
UK
EU
AU
USB-A Output Port x�
Car Charging Port
Solar Charging Port
AC Input Socket
Heat
Dissipation
Vent
Heat
Dissipation
Vent
US
x�
x�
x�
x�
x�
x�
background
�.� LCD screen
�.� Use
Short press to turn on
Long press to turn off
Battery Capacity: When the power station is charging, the SOC (State of Charge) icon will blink.
* Please refer to clause � for more details regarding error message.
Error Code
Current Input Power
Current Output Power
Wi-Fi Connection Status
Remaining Charging
and Discharging Time
Bluetooth Current Battery Level
AC Output
DC Output (including USB &
Car Port & Wireless charging)
DC Input
Power On and Off
·
To turn on the device, press the main power switch. The screen will light up, and the main power indicator will
turn on.
·
If the device remains idle for � minutes, the LCD display will automatically turn off. The LCD will light up again
when the device is plugged in or unplugged from the grid, PV, car charger, or when the key operation is used. You
can manually control the LCD display by pressing the main power switch to turn it on or off.
·
To completely power off the device, press and hold the main power switch.
Standby Mode
·
In normal operation (when power is above �%), the default standby time is set to � hour. If the AC output switch
is off, and there is no charge or discharge activity for hour, the device will automatically shut down. You can
adjust the standby time via the app.
·
When the power level reaches �% or below, the device will enter low power mode. If there is no charge or
discharge activity, the standby time will adjust based on the remaining power, and the device will automatically
shut down.
Never-Power-Off Mode
·
In normal mode, press and hold the LED light button to enable Never-Power-Off mode. The icon on the
screen will flash. Press and hold again to re-enter the automatic shutdown mode, at which point the icon
will remain steady.
Note: The automatic shutdown feature is designed to protect the battery from overdischarge. Exiting this setting
may reduce battery lifespan, so please proceed with caution.
background
Please ensure to use the standard AC charging cable provided. Connect the cable directly to a wall outlet
rated for ��A or higher. We are not liable for any damages resulting from the use of unauthorized charging
accessories or failure to follow these instructions.
�.� AC charging
Using AC Output
Short press the AC
Output Power Button
Using ��V DC Output
Using USB Output
LED Light Usage
Wireless Charging Usage
Short press the DC/Wireless output switch.
LED light button
The wireless charger supports
phones compatible with the Qi�.�
standard. To activate the wireless
charging function, briefly press
the DC/Wireless output switch
after turning on the power station.
Short press the LED light
button to cycle through five
modes: Low, Medium, High,
SOS, and Off.
The USB output is off by
default. To activate it, briefly
press the DC/Wireless
output switch after turning
on the power station.
Note: When there is no AC input, you can switch the AC off-grid output frequency( / )
by long pressing the AC output button for � seconds. The AC output icon will flash three times to
indicate successful switching.
The cigarette lighter output is off by
default. To activate it, briefly press
the DC/Wireless output switch after
turning on the power station.
· After ensuring the power station is turned on, briefly press the AC output power
switch to activate the AC output. Press it again to turn off the AC output.
· The default standby time for the AC output port is �� mins. If no load is connected
within this period, the AC output will automatically turn off. To enable the
Never-Power-Off function, press and hold the LED light button. The icon will
flash to indicate the change. Press and hold the LED light button again to exit the
Never-Power-Off setting, and the icon will stop flashing. (Note: The
Never-Power-Off mode is disabled by default. After restart, you need to press and
hold the LED light button again to turn it on.)
· The option to enable the Never-Power-Off setting is suitable for AC equipment
below ��W and pulse-operated devices.
· To conserve energy, please turn off the AC output and the Never-Power-Off mode
when it's not in use.
AC Charging Cable
· In fast charging mode, the battery can be fully charged in approximately �.� hours.
· By default, the product is set to fast charging mode when powered on.
*AC Fast Charging Mode: charging time deviation 士�.�h.
*Conditions: New battery, fully discharged at �C rate under room temperature, then rested
for � hours at room temperature before performing AC fast charging at room temperature.
background
· When using the company's solar panel to charge this product, please follow the connection guidelines
outlined in the user manual.
· Before connecting the solar panel, ensure that its output voltage is within the supported range of the
product to avoid damage.
· This product supports solar charging via the XT�� terminal. If an XT�� to MC� adapter cable is needed, please
purchase it seperately.
�.� PV charging
The user can charge the product with a solar panel as shown in the diagram.
Solar Charging Cable (XT��)
The power station can be charged via the vehicle’s cigarette lighter port. To prevent battery drain and
potential failure to start the engine, charging should only begin after the vehicle is running. Always ensure a
secure connection between the car charging port (DC ����) and the cigarette lighter adapter. We are not liable
for any losses resulting from improper operation.
Car charger cable (DC����)
�.� Car charging
�.� Wireless Charging (Optional)
Place your phone steadily on the wireless charging stand to charge devices that support the Qi�.� standard.
Note: Ensure that the DC/Wireless output is turned on before using the wireless charger. You can place your
phone flat on the wireless charger stand or at different angles for charging.
����
Solar Panel Charging Notice
To ensure system safety and stable operation, the solar
input power will automatically adjust according to the
input voltage and temperature conditions, as described
below:
�. Input Voltage: ��V‒��V
Maximum solar input power: ���W MAX
Within this voltage range, the unit can achieve its rated
maximum solar charging power.
�. Input Voltage: ��V‒��V
Maximum solar input power: ��W MAX
When the solar panel voltage exceeds ��V, the system will
automatically reduce the charging power to ensure circuit
safety and long-term stability.
�. Temperature Protection Mechanism (PV NTC)
When the PV port temperature (NTC sensor reading)
exceeds ��°C,
the solar input power will automatically be reduced from
���W to ���W MAX.
This protection mechanism prevents overheating of
internal components under high-temperature conditions
and is part of normal system operation.
Note:
Actual charging power may vary depending
on sunlight intensity, ambient temperature,
and battery state.
Rated Power
��% Power
�� �� �� �� �� �� ��
background
Important Notes for Use:
�. The Constant Power Output function is enabled by default.
The Constant Power Output function is unavailable in the following cases:
(�) AC output is turned on during charging (operates in bypass mode at this time);
(�) The Constant Power Output mode is disabled.
�. When connecting high-power appliances, connect only one appliance at a time. This avoids voltage
fluctuations caused by multiple appliances operating simultaneously from affecting the performance of other
devices.
�. The Constant Power Output function is more suitable for heating and motor-driven devices, and not
compatible with all appliances. Certain devices equipped with voltage protection (e.g., precision instruments)
are not suitable for this function. To confirm if a device can use the Constant Power Output function, please
refer to actual testing for compatibility.
�.� P-Boost function
Page Number Constant Power On Constant Power OffPage Number
Page Number Setting Item Setting ItemPage Number
The constant power output function of this product allows you to use appliances exceeding its rated power
without overloading the battery. When the power station needs to drive high-power appliances, the
inverter will intelligently adjust the power stations output power to maintain a constant actual output
power, ensuring the appliances operate reliably.
Page allows control of the Constant Power modes on/off: displaying "OFF" indicates the mode is
disabled, while displaying "On" indicates it is enabled.
On this page, short-press Button (LED Button) to enter the parameter modification mode, where the
battery percentage icon will flash. In the parameter modification mode, short-press Button ➀ (Power
Button) to toggle the Constant Power mode on or off. Short-press Button ➁ (LED Button) again to exit the
parameter modification mode and confirm the parameter changes.
In the settings interface, short-press Button (Power Button) to navigate to Page �, where the factory reset
function can be configured. The page displays "�" by default. Short-press Button ➁ (LED Button) to enter the
parameter modification mode. Use short-presses of Button ➀ (Power Button) to select whether to perform a
factory reset. When the display shows "�", short-press Button (LED Button) to exit the parameter
modification mode and execute the factory reset. The display will automatically revert to "�" after the factory
reset is completed.
Enter/Exit the Constant Power Output Function Settings Interface:
Short-press Button (Power Button) and Button (DC Button) simultaneously to enter the parameter
settings interface. Short-press Button ➀ (Power Button) to cycle through the interfaces.
����
background
�.� EPS function
�. FAQs (Frequently Asked Questions)
electrical appliance
socket
�. What kind of battery is used?
Lithium iron phosphate battery (LiFePO�).
The AC output port of the product has a high-rated power capacity, suitable for small household equipment.
We recommend verifying the power requirements of your equipment before use to ensure that the total power
consumption of all connected devices is lower than the rated power.
The time is displayed on the LCD screen, which can be referred to for estimating the runtime of equipment
with stable power consumption.
�. What kind of equipment can be connected to the AC output ports?
�. How to know it is charging?
When charging, the LCD will display the remaining charging time. The SOC icon will flicker, and input power
will be shown.
�. How to know how long the PPS can supply power?
�. How to clean the unit?
Clean the unit with a dry, soft and clean cloth or tissue.
�. How to store the unit?
Turn off the unit and store it in a dry, well-ventilated place. Avoid exposure to water. For long-term storage,
charge and discharge the unit every � months. Discharge it to �%, then charge it to ���%, and finally discharge
it to ��%‒��%.
�. Can it be taken on board an airplane?
No.
UK US EU
FR AU ZA
This product supports the EPS (Emergency Power Supply) function. To use it, connect the AC input port of the
product to the wall socket via the AC charging cable. In Bypass mode, the AC power is supplied by the grid, not
the battery. When the grid power is interrupted, the product will automatically switch to Inverter mode within
��ms, where AC power will be supplied by the battery instead of the grid. This function does not support �ms
switching. Do not connect it to devices requiring uninterrupted power supply, such as data servers or
workstations. If you choose to use it with such devices, ensure multiple tests are conducted to confirm
compatibility. It is recommended to use only one device at a time to avoid triggering overload protection.
Please note, if the device does not operate correctly or if data loss occurs due to non-compliance with these
instructions, our company will not be responsible for any resulting issues.
�� ��
background
Icon
Fault Description
Solution
Icon
Fault Description
Solution
Battery OTP
(over temperature
protection) fault
Battery UTP
(under temperature
protection) fault
OCP (over current
protection) fault
Battery under
voltage fault
Automatic shutdown. Requires charging.
Contact after-sales service if charging
fails repeatedly or is unavailable.
Abnormal INV
battery voltage
Grid voltage or
frequency fault
Abnormal INV
BUS voltage
Abnormal INV output
INV discharge overload
Charge overload
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Error code always on
Excessive Voltage
Difference
Error code always on
Remove all charging and discharging
equipment, and the fault will be automatically
cleared.
Auto shutdown, fault cleared when
temperature is restored.
When triggered during charging: Remove all
charging and discharging equipment, and the
fault will be automatically cleared.
When triggered when not charging: Remove all
charging and discharging equipment, charge
using AC or PV power, and the fault will be
automatically cleared once charging starts
successfully.
Remove all charging and discharging devices,
charge using AC or PV power, and the fault
will be automatically cleared once charging
starts successfully.
Remove all charging and discharging
equipment, the fault will be automatically
cleared, and check whether the voltage,
frequency, etc. of the charging equipment
meet the specifications.
Abnormal precharge
Remove all charging and discharging
devices, and the fault will be
automatically cleared.
Error code always on
Remove all charging and discharging
devices, and the fault will be automatically
cleared.
Remove all charging and discharging
equipment, the fault will be automatically
cleared, and check whether the load power
exceeds the equipment specifications.
Remove all charging and discharging
equipment, and the fault will be
automatically cleared. If there is a
connected load, check whether the load
power exceeds the equipment
specifications.
Remove all charging and discharging
equipment, keep away from high-temperature
sources, wait for the product temperature to
return to normal, and the fault will be
automatically cleared.
Remove all charging and discharging
equipment, keep away from low-temperature
sources, wait for the product temperature to
return to normal, and the fault will be
automatically cleared.
�. Error messages & solutions
Charging Soft Start Fault
MOSFET UTP(Under
Temperature
Protection) Fault
Error code always on
Error code always on
Error code always on
Hardware Overcurrent
Brake Protection
MOSFET OTP(Over
Temperature
Protection) Fault
Error code always on
Remove all charging and discharging
devices, and the fault will be
automatically cleared.
Remove the DC charging equipment, the fault
will be automatically cleared, and check
whether the DC input meets the specifications.
Error code always on
Error code always on
DC input hardware
overcurrent protection
DC input software
overcurrent protection
�� ��
background
Car charge cable
Icon
Fault Description
Solution
PV output OVP
(over voltage
protection) fault
Abnormal
communication
Error code always on
Error code always on
Error code always on
Car charger Output
OTP(Over-Temparature
Protection)
Error code always on
Error code always on
Error code always on Contact after-sales service for handling.
The battery voltage
is too low.
The battery is broken
DC input over
temperature protection
DC Input Overvoltage
Protection
Remove the PV input, the fault will be automatical-
ly cleared, and check whether the PV input voltage
meets the equipment specifications.
Remove the PV input, the fault will be automatical-
ly cleared, and check whether the PV input voltage
meets the equipment specifications.
Remove all charging and discharging equipment,
keep away from high-temperature sources, wait
for the product temperature to return to normal,
and the fault will be automatically cleared.
The DC output turns off automatically, remove all
charging and discharging equipment, keep away
from high-temperature sources, wait for the
product temperature to return to normal, and the
fault will be automatically cleared.
Restart the machine or change the operating
environment. If the fault is not resolved, contact
after-sales service for handling.
�. What's in the box
�. Maintenance
User manualAC cable
Power station
· It’s recommended to use or store the power station in an environment with ambient temperatures between
��°C and ��°C. Keep the unit away from water, heat sources, and metal objects to avoid damage.
· For storage periods exceeding � months, perform a cycle of charging and discharging every � months. First,
discharge to �%, then charge to ���%, and finally discharge to ��%-��% to maintain battery health.
· Do not store the power station in temperatures above ��°C or below -��°C, as this could damage the unit.
· If the battery capacity falls below �%, charge the unit to at least ��%. Storing the product with low power for
extended periods may cause irreversible damage to the cells, reducing the overall lifespan.
· If the power station has been idle for too long with insufficient battery, it will enter a "deep sleep" mode. To
reactivate it, simply charge the product.
· After charging or discharging, wait at least �� minutes before using the power station to ensure optimal
performance and safety.
When charging with PV panels, please
connect the cable to the XT�� terminal.
For car charger usage, connect the cable
to the DC���� terminal.
Important:
If a warning appears during product use, and the warning icon remains after restarting the device, please
stop using the product immediately. Do not attempt to charge or discharge it.
If the issue persists and the above steps do not resolve the problem, please contact customer service for
further assistance.
XT��(For Solar charging)
DC����(For Car Charging)
�� ��
background
�. Disclaimer
· The product is equipped with a built-in battery management system, which provides several protections
including overcharge, overdischarge, overcurrent, short circuit, high and low temperature, and abnormal
communication. During use, these protections may activate and cause an interruption in output. The company
is not responsible for any indirect losses caused by accidental power failures, including those affecting medical
equipment or servers. Additionally, any damage resulting from improper use, tampering, or human error is not
the responsibility of the company.
· Before using the power station, please thoroughly read this user manual to ensure proper understanding and
safe usage. After reviewing the manual, please store it in a safe place for future reference. Improper operation
can lead to serious injury, product damage, or property loss. By using the power station, you acknowledge and
accept all terms and conditions outlined in this manual. Users are fully responsible for their actions and any
consequences resulting from non-compliance.
· In accordance with applicable laws and regulations, the company reserves the right to make the final
interpretation of this document and all related materials for this product. The content may be updated, revised,
or discontinued without prior notice. Please visit the official website for the most up-to-date product
information.
FCC Statement
This device complies with Part �� of the FCC Rules. Operation is subject to the following two conditions:
(�)This device may not cause harmful interference.
(�)This device must accept any interference received, including interference that may cause undesired operation.
�. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
Note:This equipment has been tested and found to comply with the limits for a class B digital device,pursuant to Part �� of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequence energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipmemt does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an autlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a
minumum distance of �� cm between the radiator and your body.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development
Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment should be installed and operated with a minimum distance of �� cm between the radiator and your body.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables auxappareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes :
(�)l'appareil ne doit pas produire de brouillage, et (�) l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre lefonctionnement. Cet équipement doit être installé et utilisé avec une
distance minimale de �� cm entre le radiateur et votre corps.
��

Specifications

CE LINK 300W PRO Questions and Answers

Questions and Answers