Page1of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
SECTION1:PRODUCTANDCOMPANYIDENTIFICATION
ProductName: Lithium‐ionBatteries‐Rechargeable DrawingNumber: 58‐97‐0500
IssueDate: January2018
SupersedesDate: April2016
MilwaukeeElectricToolCorporation CompanyPhoneNumber: 262‐781‐3600or
13135WestLisbonRoad 1‐800‐729‐3878
Brookfield,WisconsinUSA53005‐2550 EmergencyContactNumber: 1‐800‐424‐9300
www.milwaukeetool.com Chemtrec:UnitedStatesonly
ForInternational:+1‐703‐741‐5970
SECTION2:HAZARDSIDENTIFICATION
Health Environmental Physical
EyeIrritation:Noclassifiedhazards AcuteToxicity: Noclassifiedhazards Flammableliquid:Noclassifiedhazards
SkinIrritation:Noclassifiedhazards ChronicToxicity: Noclassifiedhazards
AcuteToxicity,Oral:Noclassified
hazards
AcuteToxicity,Inhalation:Noclassified
hazards
GHSLabel
Noapplicablelabeling
HazardStatements PrecautionaryStatements
Noexposureduringroutinehandlingofproduct
CLASSIFIEDHAZARDS
ThismaterialisnothazardousunderthecriteriaoftheFederalOSHAHazardCommunicationStandard29CFR1910.1200.This
SDScontainsvaluableinformationforthesafehandlingandproperuseofthisproduct.SavethisSDSforfuturereference.
OTHERHAZARDS
Flammable:
Organiccomponentswillburnifcellisincinerated.CombustionofcellcontentsmaycauseevolutionofHydrogenFluoride.
PotentialHealthEffects:
Fluorideinterfereswithnerveimpulseconductioncausingseverepainorabsenceofsensations
WARNING:
Noexposureduringroutinehandlingofproduct.HydrofluoricAcidexposureduringfirefighting:Thisinformationisgiven
fortheuseofprofessionalfirefightersrespondingtoawarehousefirewherefirefromothermaterialsmayincinerate
batteries.Thissectionisprovidedsolelyincaseofexposure,duringfirefighting,tothecombustionby‐products.
Product Information Sheet
MaybeusedtocomplywithOSHA’sHazardCommunication
Standard29CFR1910.1200.
Thisstandardmustbeconsultedforspecificrequirements.

Page2of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
SECTION3:COMPOSITION/INFORMATIONOFINGREDIENTS
ChemicalName CAS# Concentration
AluminumFoil 7429‐90‐5 0.1‐ 10
Biphenyl(BP) 92‐52‐4 0.1‐ 0.3
CopperFoil 7440‐50‐8 0.1‐ 10
Linear&CyclicCarbonatesolvents N/A 0‐ 17
GraphitePowder/Carbon 7440‐44‐0 10‐ 30
MetalOxideorotherElectrolyte(proprietary) Confidential 10‐ 50
LithiumHexaflurophosphate(LiPF
6
) 21324‐40‐3 0‐ 5
PolyvinylideneFlouride(PVDF) 24937‐79‐9 0.1‐ 5
StyreneButadieneRubber(SBR) N/A <5
Aluminum,Steel,Nickelandotherinertmaterials N/A Remainder
SECTION4:FIRSTAIDMEASURES
Noexposureduringroutinehandlingofproduct.Riskofexposureoccursonlyifthebatteryismechanicallyorelectricallyabused.
Noeffectunderroutinehandlingandusetoeyes,skinorifinhaled.Ingestionisnotlikely,giventhephysicalsizeandstateofthe
cell.Ifswallowed,seekmedicalattentionimmediately.
Ifexposuretointernalmaterialswithincellduetodamagedoutercasingthefollowingactionsarerecommended:
EYECONTACT:
Flushwithwaterfor15minuteswithoutrubbingandimmediatelyseekmedicalattention.
SKINCONTACT:
Washareaimmediatelywithsoapandwater.Ifirritationcontinuesseemedicalattention.
INHALATION:
Leaveareaimmediatelyandmovetofreshairandseekmedicalattention.
INGESTION:
Ifswallowed,contactPOISONCONTROLCENTERimmediately.
SECTION5:FIREFIGHTINGMEASURES
NFPA704HazardClassHMIS
SUITABLEEXTINGUISHINGMEDIA:
Waterspray,carbondioxide,drychemicalpowderorappropriatefoam.Useagentappropriateforsurroundingmaterials.
UNSUITABLEEXTINGUISHINGMEDIA:
None.

Page3of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
PRODUCTSOFCOMBUSTION:
Organiccomponentswillburnifincinerated.CombustionofcellcontentsmaycauseevolutionofHydrogenFluoride.Incaseof
fireinanadjacentarea,usewater,CO2,ordrychemicalextinguishersifcellsarepackedintheiroriginalcontainerssincethe
fuelofthefireisbasicallypaperproducts.
PROTECTIONOFFIREFIGHTERS:
HydrofluoricAcidexposureduringfirefighting:Thisinformationisgivenfortheuseofprofessionalfirefightersrespondingtoa
warehousefirewherefirefromothermaterialsmayincineratebatteries.Thissectionisprovidedsolelyincaseofexposure,
duringfirefighting,tothecombustionby‐products.
SECTION6:ACCIDENTALRELEASEMEASURES
PERSONALPRECAUTIONS:
Usestandardindustrialclothinginnormaluse.Ifhandlinglargecontainersofcellswearsteel‐toedfootwear.
ENVIRONMENTALPRECAUTIONS:
Nospecialprecautionsnecessary.
METHODSFORCONTAINMENT:
Transportcontaineroutdoors.Holdburnedcellsandfirecleanupsolidsfordisposalaspotentialhazardouswaste.Unburned
cellsarenothazardouswaste.Afirewithover100kgofcellsburntwilllikelyrequirereportingtoenvironmentalofficials.
Alwaysconsultandobeyallinternational,federalandlocalenvironmentallaws.
METHODSFORCLEAN‐UP:
Nodataavailable
OTHERINFORMATION:
Nodataavailable
SECTION7:HANDLINGANDSTORAGE
HANDLING:
Useonlyapprovedchargingequipment.Donotdisassemblebatteryorbatterypack.Donotpuncture,crushordisposeofinfire.
STORAGE:
Storeinacool,dryplaceawayfromsparksandflame.Keepbelow125°C.Keepabove‐60°C.Chargebetween0°Cand45°C.
SECTION8:EXPOSURECONTROLS/PERSONALPROTECTION
ChemicalName
OSHA
PEL
ACGIH
TLV
CaliforniaProp65
Reg.Y/N
IARC/NTP
Y/N
AluminumFoil TWA
5mg/m
3
*
TWA
5mg/m
3
*
N N
Biphenyl(BP) NA NA N N
CopperFoil NA NA N N
Linear&CyclicCarbonatesolvents NA NA N N
GraphitePowder/Carbon NA NA N N
MetalOxideorotherElectrolyte(proprietary) NA NA N N
LithiumHexaflurophosphate(LiPF
6
) NA NA N N

Page4of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
PolyvinylideneFlouride(PVDF) NA NA N N
StyreneButadieneRubber(SBR) NA NA N N
Aluminum,Steel,Nickelandotherinertmaterials NA NA N N
EYEPROTECTION:
Notnecessaryunderconditionsofnormaluse
SKINPROTECTION:
Notnecessaryunderconditionsofnormaluse
RESPIRATORYPROTECTION:
Notnecessaryunderconditionsofnormaluse
ENGINEERINGCONTROLS:
Notnecessaryunderconditionsofnormaluse
GENERALHYGIENECONSIDERATIONS:
Notnecessaryunderconditionsofnormaluse
EXPOSUREGUIDELINES:
Notnecessaryunderconditionsofnormaluse
SECTION9:PHYSICALANDCHEMICALPROPERTIES
Datarepresenttypicalvaluesandarenotintendedtobespecifications.NA=NotApplicable;ND=NotDetermined
Physicalstate:.................................SolidViscosity:.......................................................NA
Colour:............................................NA UpperExplosiveLimits(vol%inair):..........NA
Odor:..............................................Odorless LowerExplosiveLimits(vol%inair):...........NA
OdorThreshold:.............................NA Vaporpressure:............................................NA
pH:.................................................NA Vapordensity:..............................................NA
Melting/FreezingPoint:.................NA Relativedensity:...........................................NA
VOCContent:..................................NA Solubility:......................................................NA
BoilingPoint:..................................NA PartitionCoefficient:....................................NA
FlashPoint:.....................................NA Auto‐ignitionTemperature:.........................NA
EvaporationRate:...........................NA DecompositionTemperature:......................NA
SpecificGravity:............................NA Flammability(solid,gas):.............................Organiccomponentswill
burnifcellisincinerated
SECTION10:STABILITYANDREACTIVITY
INCOMPATIBLEMATERIALS:
Water,heatandstrongacids.
DECOMPOSITIONPRODUCTSMAYINCLUDE:
HydrogenFluoride,PhosphorusOxides,CarbonMonoxide,CarbonDioxide,LithiumHydroxide,ManganeseOxides,Aluminum
Oxide,possiblefluoro‐compounds,Carbonsoot.
CONDITIONSTOAVOID:
Donotcrush,puncture,incinerate,immerseinwaterorheatover212°F(100°C).Steelcasingslowlydissolvesinstrongmineral
acids.

Page5of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
POLYMERIZATION:
Hazardouspolymerizationwillnotoccur.Spontaneousdecompositionwillnotoccuratnormaltemperature.
CHEMICALSTABILITY:
Thisproductisstable.
REACTIVITY:
Hazardouspolymerizationwillnotoccur.Spontaneousdecompositionwillnotoccuratnormaltemperature.
SECTION11:TOXICOLOGYINFORMATION
LIKELYROUTESOFEXPOSURE: Inhalation,EyeandSkincontact
Eyecontact,skincontact,skinabsorption,inhalationonlyifburned.Hydrofluoricacidisextremelycorrosive.Contactwith
hydrogenfluoridefumesistobeavoided.Permissibleexposurelimitis3ppm.Incaseofcontactwithhydrogenfluoridefumes,
immediatelyleavetheareaandseekfirstaidandemergencymedicalattention.Symptomsmayhavedelayedonset.Fluoride
ionspenetrateskinreadilycausingdestructionofdeeptissuelayersevenbone.Fluorideinterfereswithnerveimpulse
conductioncausingseverepainorabsenceofsensations.Immediatelyflusheyesorskinwithwaterforatleast20minutesto
neutralizetheacidityandremovesomefluoride.Removeanddestroyallcontaminatedclothingandpermeablepersonal
possessions.Beforere‐use,impermeablepossessionsshouldbesoakedinbenzalkoniumchlorideafterwashing.Following
flushingoftheaffectedareas,anicedaqueoussolutionofbenzalkoniumchlorideor2.5%calciumgluconategelshouldbe
appliedtoreactwiththefluorideion.Compressesandwrapsmaybeusedforareaswhereimmersionisnotpractical.
Medicateddressingshouldbechangedevery2minutes.Exposuretohydrofluoricacidfumessufficienttocausepainrequires
immediatehospitalizationformonitoringforpulmonaryedema.
ACUTESYMPTOMSANDEFFECTS:
Inhalation: Nofurthertoxicologicaldataknown
Eyecontact: Nofurthertoxicologicaldataknown
Skincontact: Nofurthertoxicologicaldataknown
Ingestion: Nofurthertoxicologicaldataknown
OTHER:
Nofurtherdataknown.
SECTION12:ECOLOGICALINFORMATION
ECOTOXICOLOGICALINFORMATION:
Noneinroutinehandlingofproduct.
TOXICITY:
Nodataavailable
PERSISTENCEANDDEGRADABILITY(BIOPERSISTENCY&BIODEGRADABILITY):
Noneinroutinehandlingofproduct.
POTENTIALOFBIOACCUMULATION:
Noneinroutinehandlingofproduct.
MOBILITYINSOIL:
Noneinroutinehandlingofproduct.
OTHERADVERSEEFFECTS:
Nodataavailable

Page6of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
SECTION13:DISPOSALCONSIDERATIONS
DISPOSAL:
Disposeinaccordancewithappropriateregulations.Alwaysconsultandobeyallinternational,federal,provincial/stateandlocal
hazardouswastedisposallaws.Somejurisdictionsrequirerecyclingofthisspentproduct.Batteryrecyclingisencouraged.
Lithiumionbatteriesaresafefordisposalinthenormalmunicipalwastestreamsincetheyarenotdefinedbythefederal
governmentashazardouswaste.However,Lithiumionbatteriesarerecyclable.
Thisproductdoesnotcontainmercury,cadmiumorLithium(metal).
DONOTINCINERATEorsubjectbatterycellstotemperaturesinexcessof212°F(100°C).
SECTION14:TRANSPORTATIONINFORMATION
U.S.DOTHAZARDOUSMATERIALREGULATIONS(RE:GROUNDTRANSPORT)
ProperShippingDescription:
UN3480Lithium‐ionbatteries;UN3481Lithium‐ionbatteriespackedwithorcontainedinequipment;Class9.
MilwaukeeLithium‐ionbatteriesaretobeshippedincompliancewithrelevantrequirementsofHMR“49CFR173.185”.
CANADATRANSPORTDANGEROUSGOODS(RE:GROUNDTRANSPORT)
ProperShippingDescription:
UN3480Lithium‐ionbatteries;UN3481Lithium‐ionbatteriespackedwithorcontainedinequipment;Class9.
MilwaukeeLithium‐ionbatteriesaretobeshippedincompliancewithrelevantrequirementsofTDG“Part2”(Section2.43),
orTDG“Schedule2”(SpecialProvision34),asapplicable.
INTERNATIONALDANGEROUSGOODSREGULATIONS(RE:AIR,SEA,GROUNDTRANSPORT)
ProperShippingDescription:
UN3480Lithium‐ionbatteries;UN3481Lithium‐ionbatteriespackedwithorcontainedinequipment;Class9.
MilwaukeeLithium‐ionbatteriesaretobeshippedincompliancewithrelevantrequirementsofthefollowingDG
Regulations:
ICAOTechnicalInstructionsorIATADangerousGoodsRegulations(59
th
Edition):PackingInstructions965;966;967
(SectionI,orSectionII,asapplicable).
IMDGCode:PackingInstructionP903,orSpecialProvision188,asapplicable.
UNModelRegulationsontheTransportofDangerousGoods:PackingInstructionP903,orSpecialProvision188,as
applicable.
UNEuropeanAgreements(ADR/RID/ADN):PackingInstructionP903,orSpecialProvision188,asapplicable.
AustralianDangerousGoods(ADG):PackingInstructionP903,orSpecialProvision188,asapplicable.
IMPORTANT:Theproperclassification,packaging,labeling,marking,anddocumentationrequirementsforshippingLithium‐ion
batteriesisdependentuponwhethertheparticularbatteriesare:
a.) Ratedat100Watt‐hours(Wh)orless;or
b.) Ratedatgreaterthan100Wh.
Generally,Lithium‐ionbatteriesrated100Whorlessare“excepted”fromcertainClass9DGrequirements.Alwayscheck
complianceofLithium‐ionbatteryconsignmentsagainstthecurrentregulationsgoverningthechosenmodeoftransport.When
indoubt,contactthecarrierorothertrainedDangerousGoodsprofessionaltoconfirmacceptability.

Page7of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
UN38.3BATTERYTRANSPORTATIONTESTING:
MilwaukeerechargeableLithium‐ionbatterieslistedinSection1havepassedtherelevanttransportationtestrequirementsas
describedintheUNManualofTestsandCriteria,PartIII,section38.3.
UN38.3TestReportsaremaintainedonfileatthecorporateheadquartersofMilwaukeeElectricToolCorporationlocatedat
13135W.LisbonRd.,Brookfield,WI,USA53005.
SECTION15:REGULATORYINFORMATION
GLOBALINVENTORIES
TSCA:UnitedStates SeeSec.14.Compliantwith,relevanttransportationtestrequirementsasdescribedinthe
UNManualofTests&Criteria,PartIII,Sub‐section38.3.
DSL:Canada SeeSec.14.Compliantwith,relevanttransportationtestrequirementsasdescribedinthe
UNManualofTests&Criteria,PartIII,Sub‐section38.3.
ECL:Korea Compliantwith,relevanttransportationtestrequirementsasdescribedintheUNManual
ofTests&Criteria,PartIII,Sub‐section38.3.
PICCS:Philippines Compliantwith,relevanttransportationtestrequirementsasdescribedintheUNManual
ofTests&Criteria,PartIII,Sub‐section38.3.
ENCS:Japan Compliantwith,relevanttransportationtestrequirementsasdescribedintheUNManual
ofTests&Criteria,PartIII,Sub‐section38.3.
AICS:Australia Compliantwith,relevanttransportationtestrequirementsasdescribedintheUNManual
ofTests&Criteria,PartIII,Sub‐section38.3.
IECS:China Compliantwith,relevanttransportationtestrequirementsasdescribedintheUNManual
ofTests&Criteria,PartIII,Sub‐section38.3.
EINECS:EuropeanUnion Compliantwith,relevanttransportationtestrequirementsasdescribedintheUNManual
ofTests&Criteria,PartIII,Sub‐section38.3.
SARA313Information:
SARATitleIIISection313:Thisproductdoesnotcontainregulatedlevelsofanytoxicchemicalsubjecttothereporting
requirementsofSection313ofTitleIIIoftheSuperfundAmendmentsandReauthorizationActof1986(SARA)and40CFRpart
372.
CaliforniaSafeDrinkingWaterandToxicEnforcementActof1986(Proposition65)
ThisproductdoesnotcontainregulatedlevelsofanytoxicchemicalsubjecttothereportingrequirementsofCaliforniaSafe
DrinkingWaterandToxicEnforcementActof1986(Proposition65)
WHMIS:CanadianWorkplace
Thisproductdoesnotcontainregulatedlevelsofanytoxicchemicalsubjecttothereportingrequirements
SECTION16: OTHERINFORMATION
ABBREVIATIONS:
TSCA.....................ToxicSubstanceControlAct
ICAO.....................InternationalCivilAviationOrganization
IMDG......................InternationalMaritimeDangerous
OSHA....................OccupationalSafetyandHealth
IARC/NTP...............InternationalAgencyforResearchonCancer/NationalToxicologyProgram
SARA.....................SuperfundAmendmentsandReauthorizationActof1986
ACGIH...................AmericanConferenceofGovernmentalIndustrialHygienists

Page8of8 58‐97‐0500
Lithium‐ionBattery‐Rechargeable
12A
NIOSH/MSHA........NationalInstituteforOccupationalSafetyHealth/
MineSafetyandHealthAdministration
WHMIS...................WorkplaceHazardousMaterialsInformationSystem
Preparedby: MilwaukeeElectricToolCorporation
ThebatteriesreferencedhereinareconsideredexemptarticlesandarenotsubjecttotheOSHAHazardCommunicationStandard;
thereforeaSDSisnotrequired.Thissheetisbeingprovidedasaservicetoourcustomers.
Theinformationandrecommendationssetfortharemadeingoodfaithandbelievedtobeaccurateasofthedateofpreparation.
MILWAUKEEELECTRICTOOLCORPORATIONmakesnowarranty,expressedorimplied,regardingtheaccuracyofthisdataorthe
resultstobeobtainedfromthe use thereto.