The product is battery-operated and serves for contact-free temperature measuring on objects or surfaces. A laser point
serves as aiming device. The degree of emission can be modified for measuring different surfaces.
Diagnostic application for medical purposes is not admissible. Do not use any other source of energy.
Please also heed the additional safety instructions in each chapter of these instructions.
Any use other than that described above is not permitted. In addition, this involves other risks, such as e.g. eye injuries.
Safety
Safety
Safety
Safety Instructions
Instructions
Instructions
Instructions and
and
and
and Hazard
Hazard
Hazard
Hazard Warnings
Warnings
Warnings
Warnings
_ An
An
An
An exclamation
exclamation
exclamation
exclamation mark
mark
mark
mark in
in
in
in a
a
a
a triangle
triangle
triangle
triangle indicates
indicates
indicates
indicates important
important
important
important information
information
information
information in
in
in
in these
these
these
these operating
operating
operating
operating instructions.
instructions.
instructions.
instructions.
Please
Please
Please
Please read
read
read
read the
the
the
the operating
operating
operating
operating instructions
instructions
instructions
instructions through
through
through
through completely
completely
completely
completely before
before
before
before putting
putting
putting
putting the
the
the
the device
device
device
device into
into
into
into operation.
operation.
operation.
operation.
They
They
They
They contain
contain
contain
contain important
important
important
important information
information
information
information for
for
for
for correct
correct
correct
correct operation.
operation.
operation.
operation.
_ The
The
The
The warranty
warranty
warranty
warranty will
will
will
will be
be
be
be rendered
rendered
rendered
rendered invalid
invalid
invalid
invalid for
for
for
for damage
damage
damage
damage caused
caused
caused
caused due
due
due
due to
to
to
to non-compliance
non-compliance
non-compliance
non-compliance with
with
with
with these
these
these
these operating
operating
operating
operating
instructions.
instructions.
instructions.
instructions. We
We
We
We shall
shall
shall
shall not
not
not
not be
be
be
be liable
liable
liable
liable for
for
for
for any
any
any
any consequential
consequential
consequential
consequential damage.
damage.
damage.
damage.
We shall not accept liability for damage to property or personal injury caused by improper handling or non-compliance with
the safety instructions. The warranty will lapse in these cases.
• For safety and licensing reasons (CE), unauthorized conversion and/or modification of the device is not permitted.
• Due to the principle-related inaccuracy of IR temperature measuring, the displayed and the „actual“ temperature may differ
slightly. Therefore, this product may not be used for very exact temperature measuring (e.g. boiling or melting points,
chemical reactions, etc.).
Do not expose the device to high temperatures, strong vibrations or a high level of humidity.
• Never look into the laser beam and never point it at persons or animals. Laser radiation may lead to eye or skin injuries.
• Do not point the laser beam on mirrors or other reflecting areas. The uncontrolledly deflected beam could hit persons or
animals.
• Keep the device and the batteries out of the reach of children. They are not a toy.
• This product is equipped with a class 2 laser according to EN 60 825-1. Apart from a battery change, the device may not
be opened. Setting or maintenance tasks must only be executed by a trained
Caution - if operation settings or procedures others than described here in these instructions are used, this could lead to a
dangerous radiation exposition.
Description
Description
Description
Description of
of
of
of Individual
Individual
Individual
Individual Parts
Parts
Parts
Parts
1 Output opening for the laser beam
2 IR-Temperature sensor
3 „SET“ button for mode setting
4 LC display (LCD = liquid crystal display)
5 „MEAS“ button for measuring
6
Hand Strap
7 „LASER/UP-DOWN“ button for changing the
Inserting/replacing
Inserting/replacing
Inserting/replacing
Inserting/replacing the
the
the
the batteries
batteries
batteries
batteries
_ Keep batteries out of the reach of children.
PMIR15
pyleaudio.com

Do not leave the batteries lying around in the open; there is the risk of them being swallowed by children
or domestic animals. If swallowed, consult a doctor immediately.
Make sure that the polarity is correct when inserting the batteries.
Remove the batteries when the device is not being used for long periods of time.
Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use suitable protective
gloves.
Batteries must not be short-circuited or thrown into fire. There is a risk of explosion!
Never take the batteries/ apart!
Always exchange the complete set of batteries; do not mix full batteries with empty/half-empty batteries. Never use batteries
and accumulators together.
• Open the battery compartment on the back of the IR thermometer by sliding it in the direction of the arrow.
• Insert two micro-batteries (AAA) in the battery compartment observing the correct polarity. You will find the corresponding
illustration in the battery compartment.
• Close the battery compartment in reverse order.
• If the battery icon appears on the display, exchange the batteries immediately to prevent false measuring results.
Initial
Initial
Initial
Initial operation
operation
operation
operation
Operating
Operating
Operating
Operating principle
principle
principle
principle
IR thermometers measure the surface temperatures of objects. The device’s sensor measures the emitted, reflected and
penetrated
heat radiation of the object and converts this information into a temperature value.
Measuring
Measuring
Measuring
Measuring temperatures
temperatures
temperatures
temperatures
Direct the opening of the IR sensor onto the object or surface to be measured and press „MEAS“ (5).
As long as the button is kept depressed, the temperature is measured and displayed (the display shows „SCAN“). The last
measured value is displayed on the LC display (the display shows „HOLD“).
The IR thermometer shuts off automatically after approx. 12 seconds. Make sure that the surface to be measured is larger
than the measuring spot. The ratio of the distance to spot ratio (D/S) is 6:1 with this IR thermometer. This means, that with a
measuring distance of 60 cm, the measuring spot has a diameter of approx. 10 cm.
For exact measuring, the measuring object should be at least twice as large as the measuring spot (hold the IR thermometer
closer to the measuring object, if applicable).
The temperature displayed by the IR thermometer is the average temperature of this measuring spot!
Activating
Activating
Activating
Activating the
the
the
the laser
laser
laser
laser
A switchable laser enables the easier positioning of the measuring spot. Make sure that the laser point is approx. 16 mm
away
from the center of the measuring spot (see sketch).
Turn the IR thermometer on (button „MEAS“) and briefly press the button „LASER“ (6). A small laser icon appears on the
display
(triangle with a sun icon). Now the laser is activated automatically during measuring. To turn the laser off, press the button
„LASER“ (6) again and the laser icon on the display disappears again.

Setting
Setting
Setting
Setting the
the
the
the measuring
measuring
measuring
measuring functions
functions
functions
functions
The IR thermometerHT-280H can perform different measuring functions.
To access setup mode, press the button „SET“ when the thermometer is turned on (button
„MEAS“).
The „SET“ button takes you to the next respective menu point and the button „LASER“ changes
the parameters. The active function is displayed on the display.
Menu
Menu
Menu
Menu sequence:
sequence:
sequence:
sequence:
MAX/MIN: Display of the minimum or maximum value. (MAX / MIN / Off = no icon).
Switching the temperature unit from Celsius (°C) to Fahrenheit (°F) and vice-versa.
Increasing the degree of emission „E“ (max. 1.00)
Decreasing the degree of emission „E“ (min. 0.10)
Setting for permanent measuring (lock icon).
OFF = Measuring only takes place when the measuring button is depressed
ON = Permanent measuring is activated, the device does not switch off after 12 s. To deactivate
this mode, press the button „Laser“. The castle icon goes off.
Raising the alarm level
Lowering the alarm level
Activating the temperature alarm.
OFF
ON = The measuring device emits a warning sound when exceeding the previously set alarm
level.
Tips
Tips
Tips
Tips and
and
and
and information
information
information
information
• The emission degree described the energy emission characteristics of a material. The higher this value is, the more
radiation
a material may emit (thermal radiation). Many materials have a value that is close to the preset value „0.95“ of the IR
thermometer.
Metallic shiny surfaces have a lesser degree of emission than
matte black surfaces.
Therefore, the degree of emission must be preset accordingly.
In this case, attaching an adhesive strip (or lacquer with matte black paint, if possible), helps to be able to measure with
the common emission degree of 0.95.
• Measuring through a glass pane is not possible, instead, the temperature of the glass pane is displayed.
Maintenance
Maintenance
Maintenance
Maintenance and
and
and
and Cleaning
Cleaning
Cleaning
Cleaning
Periodically check the technical safety of the device.
It can be assumed that risk-free operation is no longer possible if:
• there is visible damage to the appliance or

• the device has been stored under unfavourable conditions for a longer period of time
Periodically clean the surface of the IR sensor with a clean, soft brush and a vacuum cleaner. The outside of the appliance
should be cleaned with a clean dry cloth or brush only. Do not use abrasive or chemical cleaning agents which could damage
the housing or impair operation.
Never try to open the housing, apart from the battery compartment.
Disposal
Disposal
Disposal
Disposal of
of
of
of spent
spent
spent
spent Accumulators/Batteries
Accumulators/Batteries
Accumulators/Batteries
Accumulators/Batteries
The end user is legally obliged (German
(German
(German
(German battery
battery
battery
battery law)
law)
law)
law) to return all used batteries. Disposal
Disposal
Disposal
Disposal in
in
in
in household
household
household
household waste
waste
waste
waste is
is
is
is
prohibited.
prohibited.
prohibited.
prohibited.
Batteries and accumulators containing hazardous substances are marked with the shown symbols indicating that
they must not be disposed of in the household waste. The heavy metals concerned are: Cd
Cd
Cd
Cd
= cadmium, Hg
Hg
Hg
Hg = mercury, Pb
Pb
Pb
Pb = lead. You can return flat batteries/rechargeable batteries free of charge to the collection
points in your community, our branches or anywhere else where batteries or rechargeable batteries are sold.
You will thus carry out your legal obligations and contribute to the protection of our environment.
Disposal
Disposal
Disposal
Disposal
Old electronic devices are valuable materials. When the device has become unusable, dispose of it in accordance with the
current statutory regulations at your communal collection points. Disposing of flat batteries/accumulators in the household
waste is prohibited!
Technical
Technical
Technical
Technical Data
Data
Data
Data
Operating voltage ....................................................................: 3 VDC (2x micro-batteries AAA)
Automatic switch-off ..............................................................: approximately 12 seconds
Laser ....................................................................................: <1mW, red
display ....................................................................................: 3.5-digit, LCD
Weight ....................................................................................: approx. 76g
Dimensions (LxWxH)................................................................: 94 mm x 51 mm x 25 mm
Measuring
Measuring
Measuring
Measuring data
data
data
data
Measuring range ....................................................................: -50°C to +280 °C
Display resolution....................................................................: 0.1°C
Measuring accuracy (at 18°C to 28°C) ....................................: +
2.5% or +2°C)
Degree of emission ................................................................: 0.10 to 1.00, digitally adjustable
Ratio distance/spot..................................................................: 6:1
Alarm range ............................................................................: -35°C to +228°C
Ambient
Ambient
Ambient
Ambient conditions
conditions
conditions
conditions
Working temperature range ....................................................: 0°C to 50 °C
Relative air humidity: .............................................................. <80% (non-condensing)