Typhur SYNC GOLD DUAL 2-Probe Wireless Meat Thermometer

Product's Documents

Below are documents related to this product, you can read online or download:
SYNC GOLD DUAL photo

User Manual

This is the main product document for model SYNC GOLD DUAL.

The file format is pdf, 21 pages, you can download this manual here .

background
Typhur Sync Gold Dual
User Manual
US Version
v1.0 2024.05
background
Activate your 3-year warranty
within 30 days after purchase
with the QR code :
background
Typhur Sync Gold Dual User Manual
01
Copyright © 2024 Typhur Inc. All rights reserved.
IMPORTANT SAFEGUARD
CAUTION: Please read this entire manual before using your Typhur Sync Gold
Dual. Failure to follow these instructions could result in property damage or
bodily injury.
8
DO NOT use the Probe when cooking at temperatures above 662°F for 20
minutes, or above 752°F for 2 minutes
DO NOT place the Device Base unit directly on the grill cover or close to any
hot surface
DO NOT use the Probe in a microwave or pressure cooker
DO NOT use cleaning products containing alcohol, ammonium, benzene, or
abrasives, all of which could damage the device
DO NOT submerge the Probe in water for long periods of time
DO NOT run the Probe under cold water immediately after cooking. Let the
probe cool down prior to washing
The Device Base is NOT waterproof and should not be submerged in water
or placed in the dishwasher. The probe is SHARP! Care should be exercise
when handling the probe. This appliance should NOT be used by or near
children or individuals with certain disabilities
If the Probe falls into a re or direct heat source, turn off the cooking
appliance and close the lid immediately. Allow the Probe to cool completel
before removing.
background
Typhur Sync Gold Dual User Manual
02
Copyright © 2024 Typhur Inc. All rights reserved.
10
Carefully remove the Probe from the cooked meat, taking caution as it may
be hot
The Device Base shall only be supplied with safety extra-low voltage (SELV)
corresponding to the marking on the appliance
Save these Instructions.
background
5
Ambient Temperature Sensor (Ambient Max 932 °F
Internal Temperature Sensor 1 - 5 (Internal Max 221 °F
Safety Notc
Stainless Stee
High-density Ceramic Handle
Diagram
- Probe 1
- Probe 2
Copyright © 2024 Typhur Inc. All rights reserved.
Typhur Sync Gold Dual User Manual
03
23415
background
5
2.4" TFT Scree
Touch Capacitive Contro
Type-C USB (5V 1400mA minimum required
Probe Icon (Identify each Probe through the number
Stan
Diagram
Copyright © 2024 Typhur Inc. All rights reserved.
Typhur Sync Gold Dual User Manual
04
1
4
2
5
3
background
Typhur Sync Gold Dual User Manual
05
Specications
Copyright © 2024 Typhur Inc. All rights reserved.
Probe:
Number of Temperature
Sensors
6 (5 Internal and 1 Ambient)
Temperature Range
Internal 32 °F - 221 °
Ambient 32 °F - 932 °F
Accuracy Internal ±0.5 °F
Dimensions 5.08" (L) x0.22" dia
Water Resistance IPX8
Bluetooth Output Power +13dBM
Probe Material Stainless Steel + Ceramic
background
Typhur Sync Gold Dual User Manual
06
Specications
Copyright © 2024 Typhur Inc. All rights reserved.
Device Base:
Display 2.4" TFT LCD
Dimensions 5.5" x 3.4" x 1.1"
Water Resistance IPX2
Battery 3.7 volts 3020 mAh
Connection Bluetooth/Wi-Fi (device only supports 2.4 GHz Wi-Fi)
Sleep Mode
Device will automatically enter default Sleep Mode after
minutes if the Probe is removed
background
Using for the First Time:
Before using your Typhur Sync Gold Dual, ensure the product is fully
charged and you have reviewed the important safety information
Download the free Typhur App for iOS or Android
Insert the probe completely into the meat, ensuring that it passes the
safety notch but does not exceed the zirconia ceramic handle and that
the internal sensors are in the center of the meat.
Copyright © 2024 Typhur Inc. All rights reserved.
Typhur Sync Gold Dual User Manual
07
background
Typhur Sync Gold Dual User Manual
08
1 Bluetooth Indicator
3 Battery Indicator
Rechargeable Device Bas
5 Left/Right Button
Select an item
Operation:
2 Wi-Fi Indicator
4 Probe Interface
Display the battery status of the Probe,
temperature, and remaining time
6 Power/Conrm Button
Turn the Device Base ON or OFF; execute the
selected command
Copyright © 2024 Typhur Inc. All rights reserved.
Panel Instruction
1
2
3
5
6
4
background
Typhur Sync Gold Dual User Manual
09
To power on the Device Base, press the "O" button for 3 seconds. The Device Base will activate and
the buttons will illuminate.
Power On
Sleep Mode
The Device Base automatically enters default Sleep Mode after 5 minutes of Probe inactivity. The
default Sleep Mode time can b
changed via the Typhur App. When in Sleep Mode, the display turns off, the "<" and ">" buttons
cease to illuminate, and the "O"button emits a pulsing light.
Power Control
Power Off
Copyright © 2024 Typhur Inc. All rights reserved.
Press and hold the "O" button for 3 seconds to shut down the screen. When cooking, select "Stop"
on the screen prompt of "Stop the Current Cooking" to power off the Device Base. The Probe will
automatically power off after 30 minutes of being plugged into the Device Base.
The screen will enter locked mode after 30 seconds of inactivity on the main page. To unlock the
screen, simply touch any key. The screen will then return to its previous state.
Screen Lock Mode
background
Typhur Sync Gold Dual User Manual
10
For rst-time use, you will see the "Pair Typhur App" prompt on the Device Base
Open the Typhur App on your smartphone or tablet. Tap on "Devices" and select "Add Device".
Select Typhur Sync Gold Dual and follow the instructions to pair your device.
The device will actively connect to Wi-Fi when within range of a Wi-Fi signal. This ensures that the
Typhur App instantly receives any messages from the Device Base. The device will display the signal
strength of the currently connected Wi-Fi network through the "Wi-Fi" icon.
Wi-Fi connection (highly recommended)
Connectivity
Pair the Typhur App
Copyright © 2024 Typhur Inc. All rights reserved.
The device can also connect to and push messages to the Typhur App via Bluetooth. However, this
connection method does not guarantee that the app will receive all messages instantaneously.
Please note that the Wi-Fi connection is more reliable than the Bluetooth connection.
Bluetooth connection
background
Typhur Sync Gold Dual User Manual
11
Copyright © 2024 Typhur Inc. All rights reserved.
Press "<" and ">" simultaneously for 5 seconds to enter the "Reset" mode. Follow the prompts to
complete the operation.
Restore Factory Settings
background
Typhur Sync Gold Dual User Manual
12
Copyright © 2024 Typhur Inc. All rights reserved.
Cooking
Unplug either Probe to be used, and the Device Base's screen will display the "Set up cook" prompt
You can adjust your temperature unit preference via the Typhur App.
Temperature Setting
Smart Mode
Smart Mode will predict when the meat should be removed from the heat source, based on its target
temperature and the rate of warming. You will be alerted when the meat is both removed from the
heat and when it is ready to serve.
background
Typhur Sync Gold Dual User Manual
13
Copyright © 2024 Typhur Inc. All rights reserved.
Manual Mode
Receive alerts only when the temperature reaches the set temperature.
Cooking States
This state indicates that the food should be removed from the heat source.
Remove from heat
background
Typhur Sync Gold Dual User Manual
14
Copyright © 2024 Typhur Inc. All rights reserved.
The food has entered a resting state, allowing the residual heat to continue to rise.
The food is cooked and ready to be served. Click "O" button to end the cooking process.
Resting
Ready
background
Typhur Sync Gold Dual User Manual
15
Copyright © 2024 Typhur Inc. All rights reserved.
Troubleshooting
Device Base Prompt
"Probe Battery Low
"Device Battery Low
"Overheating
"Error 403"
Possible Cause
The Probe's battery power is at a low
level.
The Device Base's battery power is at a
low level.
The Probe has been exposed to an
overheated environment
There may be a software, hardware
sensor, or communication failure.
Solution
Plug the Probe into the Device Base to
charge it.
Use the included Type-C USB cable to
charge the Device Base.
R
emove the Probe from the heat source
and allow it to cool down before using it
again.
Contact our customer support team fo
assistance. They will be able to help yo
diagnose and resolve the issue.
Contains FCC ID:
2B
EFM
-
W
T1000
Contains IC:
3
1
88
4-
W
T1000
FCC ID:
2B
EFM
-
W
TP200
IC: 3
1
88
4-
W
TP2000
Certi
cations
:
background
Typhur Sync Gold Dual User Manual
16
Copyright © 2024 Typhur Inc. All rights reserved.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions
 This device may not cause harmful interference
 This device must accept any interference received, including interference that may cause
undesired operation
This equipment has been tested and found to comply with the limits for a Class B digital device
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protectio
against harmful interference in a residential installation. This equipment generates uses an
can radiate radio frequency energy and, if not installed and used in accordance with th
instructions, may cause harmful interference to radio communications. However, there is n
guarantee that interference will not occur in a particular installation. If this equipment doe
cause harmful interference to radio or television reception, which can be determined by turnin
the equipment off and on, the user is encouraged to try to correct the interference by one or mor
of the following measures
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced radio/TV technician for help
CAUTION: The user is cautioned that changes or modications not expressly approved by the part
responsible for compliance could void the user's authority to operate the equipment.
FCC Radiation Exposure Statement:
The device complies with RF specications when used near your body at a distance of 10 mm.
Ensure that the device accessories, such as a device case and device holster, are not composed of
metal components. Keep the device away from your body to meet the distance requirement.
background
Typhur Sync Gold Dual User Manual
17
Copyright © 2024 Typhur Inc. All rights reserved.
FCC Supplier's Declaration of Conformity
Product Name: Typhur Sync Gold Dual Wireless Thermomete
Model number: WT0
Suppliers Name: Typhur Inc
Suppliers Address (USA): 2890 Zanker Rd, Suite 120, San Jose, CA9513
Suppliers contact mail: allen.f@typhur.com
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science
and Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following
two conditions
 This device may not cause interference
 This device must accept any interference, including interference that may cause undesired
operation of the device
This equipment complies with Industry Canada radiation exposure limits set forth for an uncontrolled
environment.
ISED Radiation Exposure Statement
The device complies with RF specications when used near your body at a distance of 10 mm.
Ensure that the device accessories, such as a device case and device holster, are not composed of
metal components. Keep the device away from your body to meet the distance requirement.
This symbol, afxed to the product or its packaging, indicates that the product must not
be processed with household waste. It must be brought to an electric or electronic waste
collection point for recycling and disposal.
B
y ensuring the Appropriate disposal of this
product you also help in preventing potentially negative consequences for the
environment and human health. The recycling of materials helps preserve our natural
resources. For further information regarding the recycling of this product, please contact
your municipality, local waste disposal center, or the store where the product was
purchased.
background
Typhur Sync Gold Dual User Manual
18
Copyright © 2024 Typhur Inc. All rights reserved.
Support
Please contact our Customer Support Team if you have any questions
1(888) 838-6563 (USA
support@typhur.co
www.typhur.com/contact-us (USA)
Typhur Privacy Statement
We value your privacy and personal data rights, and we, Typhur Inc. are the entity responsible for the
collection, use, and disclosure of information under our Privacy Statement. For more details, please
visit https://www.typhur.com/privacy-statement.
Terms of Service
For details about Typhur Terms of Service, please visit https://www.typhur.com/terms-of-service.
Refund & Return Policy
Typhur has a 30-calendar day hassle-free return policy
For more details please visit: https://www.typhur.com/refund-and-return.
3-Year Warranty
Activate your 3-year warranty within 30 days after purchase with the QR code below
Full details are stated in Typhur's warranty policy at www.typhur.com/warranty.
background
WE ARE HERE FOR YOU
Contact
Typhur Support
If you have any questions about this document,
please contact Typhur by sending a message to support@typhur.co
© 2024 Typhur Inc. All rights reserved.

Specifications

Typhur SYNC GOLD DUAL Questions and Answers