Rinnai 8 HW_CF OIM
MAXIMUM DELIVERY TEMPERATURES
Rinnai continuous ow water heaters are factory pre-set to various maximum delivery temperatures depending on
model and their intended application� For the majority of applications, the factory pre-set temperature is appropriate�
In the unlikely event this is not the case this setting can be increased or decreased by an authorised person such
as a licensed plumber
NOTE
This does not apply to “50 degree compliant” models� To meet the regulatory requirements the
maximum delivery temperature is factory set and sealed�
For model specic information in regards to the factory pre-set temperature of your appliance
refer to "Table 3� Maximum Delivery Temperatures" on page 27� The appliance model number
can be found on the dataplate, which is located on the left hand side of appliance�
OPERATION WITHOUT WATER CONTROLLERS
Rinnai Continuous Flow water heater products do not use a pilot light� When installed and operated without water
controllers, the opening of any hot water tap will automatically start the appliance. Once water is owing through
the appliance the burner will be ignited by electronic ignition. When the hot water tap is closed and water owing
through the appliance has stopped the burner ame will extinguish.
RINNAI WATER CONTROLLERS
NOTE
Other manufacturers water controllers are NOT compatible with Rinnai water heaters� Rinnai
water controllers brought in from other countries are also NOT compatible with Rinnai appliances
sold in Australia�
Water controllers MUST NOT be used with any Solar Boost water heater
Water controllers are available as an optional extra� Wireless, Universal and Deluxe water controllers can be
used together and will function as described in the Operation Sections of this manual� Refer to "Water Controller
Combinations & Congurations" on page 9 to conrm the maximum number and combination of water
controllers that can be tted to your water heater model.
Location
Water controllers must be installed in shaded and clean locations. They should be tted out of reach of children
(suggested height from oor to be at least 1500 mm).
Water Resistance
The MC-601Q universal water controller is a water resistant device, however excessive exposure to water such as
immersion may result in damage to the water controller� Durability of water controllers is improved when positioned
outside of the shower recess�
NOTE
Controllers MUST BE installed at least 400 mm above the highest part of a sink, basin or bath�
DO NOT immerse the water controller into water
AVOID direct exposure to water or steam as these conditions may cause a malfunction�
ALWAYS AVOID exposure to water when the battery compartment is open�
When cleaning your water controller use ONLY a damp cloth and a mild detergent�
WATER TEMPERATURE CONTROL