AXISP8815-23DPeopleCounter
Additionalsettings
1.Inthedevice’swebpage,gotoSetup>Occupancy.
2.UnderAllowevents,enter50inHigherthreshold.
Createadeviceeventtrigger
1.InAXISCameraStation,click
andgotoConguration>Recordingandevents>ActionrulesandclickNew.
2.ClickAddtoaddatrigger.
3.SelectDeviceeventfromthelistoftriggersandclickOk.
4.IntheConguredeviceeventtriggersection:
-InDevice,selectthedevice.
-InEvent,selectA3DPCOccupancyEvent-High.
-InTriggerperiod,setanintervaltimebetweentwosuccessivetriggers.Usethisfunctiontoreducethenumber
ofsuccessiverecordings.Ifanadditionaltriggeroccurswithinthisinterval,theeventwillcontinueandthe
triggerperiodstartsoverfromthatpointintime.
5.InFilters,setactivetoYes.
6.ClickOk.
Createactionstosendnoticationstothemobileapp
1.ClickNext.
2.ClickAddtoaddanaction.
3.SelectSendmobileappnoticationfromthelistofactionsandclickOk.
Note
Themessageiswhatthereceiverseeswhenanalarmistriggered.
4.InMessage,enterthemessagetosendwhentheoccupancylimitisexceeded.
5.SelectDefault.ThisopensthemainpageoftheAXISCameraStationMobileappwhenthereceiverclicksthenotication.
6.ClickOk.
Specifywhenthealarmisactive
1.ClickNext.
2.Ifyouonlywantthealarmtobeactiveduringcertainhours,selectCustomschedule.
3.Selectaschedulefromthelist.
4.ClickNext.
5.Enteranamefortherule.
6.ClickFinish.
Occupancystatuspages
Ifyouwanttovisualizethecurrentoccupancyleveltoanoperatorordirectlytocustomers,youcanusetheoccupancystatuspages.
http://<servername>/a3dpc/index.html#/occupancy-operator-view:Thepageshowshowmanypeoplearecurrently
inthepremises,andwhetherthatnumberislow,medium,orhighoccupancy.GotoSetup>Occupancy>Events
todenethethresholds.