7.2.1 Recommended Scene
This part introduces the recommended scenes of re source detecon and helps you select the
appropriate scene.
Fire source
detecon can be applied to indoor and outdoor monitoring with a large detecon
radius. To achieve the best monitoring eect, please set the installaon place as requirements
below.
●
The installaon place should be the highest posion within the detecon area. The lens should
not be covered during movement to detect the maximum area.
●
It is beer to choose the installaon place with convenient trac, well-equipped power and
internet facilies (e.g., communicaon tower, watchtower and high-rise roof).
7.2.2 Set Dynamic Fire Source
Detecon
To avoid the potenal re damage, you can congure the re detecon funcon for certain areas.
The detail conguraon steps show as below.
Before You Start
Go to
Conguraon → System → Maintenance → VCA Resource Type , select Temperature
Measurement + Perimeter Protecon.
Steps
1.
Go to Conguraon → Local .
2.
Check Locate Highest Temperature Point to display the
posion of highest temperature. Check
Frame Fire Point to frame the re source on live view.
3.
Go to Conguraon → Event → Smart Event , select Dynamic Fire Source Detecon.
4.
Check Enable Dynamic Fire Source
Detecon.
5.
Set the parameters of re detecon.
Fire Source Detecon
Smoking Mode
Detect smoking behavior in the scene.
Dynamic Fire
Detect the dynamic re source in the scene.
Sensivity
The sensivity of re detecon. The bigger the value is, more easily the re source can be
detected, and the false rate is higher.
Alarm Interval
Set the alarm interval between two alarms.