Hikvision DS-2TD2117-3/PI Thermal Network Bullet Camera

User Manual - Page 56

For DS-2TD2117-3/PI.

PDF File Manual, 96 pages, Read Online | Download pdf file

DS-2TD2117-3/PI photo
Loading ...
Loading ...
Loading ...
Check to add data on alarm triggered capture of thermal channel.
Picture Quality
Set picture quality as high, medium, or low.
Add Original Data on Stream
Add and save original raw data to stream. The funcon requires higher network bandwidth.
Data Refresh Interval
It means the refresh interval of original data.
Display Pixel-to-Pixel Thermometry Data on Stream
Add and save
real-me pixel-to-pixel thermometry data to stream. The funcon requires
higher network bandwidth.
The funcon varies according to dierent camera models.
Pixel-to-Pixel Thermometry Data Refresh Interval
It means the refresh interval of thermometry data added to the stream.
Unit
Display temperature with Degree Celsius (°C)/Degree Fahrenheit (°F)/Degree Kelvin (K).
Temperature Range
Select the temperature measurement range. The device can adjust the temperature range
automacally if you select Auto.
Atmospheric Temperature
Set the atmospheric temperature.
Atmospheric Humidity
Set the atmospheric humidity.
Atmospheric Transmissivity
Set the atmospheric transmissivity from 0 to 1.
Distance Mode
Select the distance mode for temperature measurement. Fixed Distance and
Self-Adapon
are selectable. Fixed distance mode is suitable for xed objects or objects move in a very
small area.
Self-adapon mode is suitable for moving objects. In this mode, device
automacally adjusts parameters according to the distance to objects, so as to ensure
temperature measurement accuracy.
Version
View the version of current algorithm.
Calibraon File Version
View the version of calibraon le.
Alarm Interval
Set the alarm interval between two alarms.
Thermal Network Camera User Manual