![](https://files.manualsfile.com/24948726-wdv0904/bg22.png)
56V LITHIUM-ION WET/DRY VACUUM CLEANER — WDV0900/WDV0900-FC34
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
The vacuum
cleaner fails to
start.
◾
Battery pack charge
is low.
◾
Charge the battery pack.
◾
Battery pack is not
installed properly.
◾
Slide the battery pack onto the vacuum
cleaner until it snaps into position.
Vacuum power is
weak
◾
There is a blockage in
the vacuum hose or the
suction inlet.
◾
Check and clear the blockage in the
vacuum hose or the suction inlet.
◾
The filter is clogged by
fine dust.
◾
Clean the filter following the section
“FILTER MAINTENANCE” in this manual.
◾
The dust tank is full.
◾
Empty the dust tank.
◾
Battery pack charge
is low.
◾
Charge the battery pack.
◾
The drain port cap is
removed from the dust
tank.
◾
Install the drain port cap onto the dust
tank.
The machine is
running but there
is no suction.
◾
The power head
assembly is not
installed onto dust tank
completely.
◾
Ensure the power head assembly is
installed onto the dust tank completely
Dust escapes
from the blowing
outlet port.
◾
Filter is missing or
installed incorrectly.
◾
Check the filter for correct installation.
◾
Filter is damaged.
◾
Replace with a new filter.
Loading ...
Loading ...