Brondell RC250 H2O+ Collection Capella Reverse Osmosis Water Filtration System, WQA Gold Seal Certified with Eco-friendly 11 Wastewater Ratio in White

User Manual - Page 24

For RC250.

PDF File Manual, 104 pages, Read Online | Download pdf file

RC250 photo
Loading ...
Loading ...
Loading ...
22
Step 5
Step 7a
Step 7c
Step 7d
For California Residents: CR2032 batteries contain Perchlorate
Material — special handling may apply.
Visit www.dtsc.ca.gov/hazardouswaste/perchlorate for more information.
b. With the top and bottom arrows still lined up, insert the top of
the filters into the housing and turn to the right until the filters
will not turn anymore.
5. Open the T-valve to restore the flow of water to the Capella.
6. Flush the new filters and the system thoroughly with the
following steps.
a. Turn the faucet on all the way for 10 minutes to purge all the
air out of the system. It is normal for some water to flow out of
the faucet during this first purge.
b. After the initial 10-minute purge, turn the faucet o and let the
system run for 90 minutes or until the tank fills.
c. After 90 minutes, turn the faucet on all the way once more for
10 minutes (or until the tank empties) to flush the filters and
the water tank.
d. Turn the faucet o.
e. The tank will fill again in about 90 minutes, and then filtered
water will be ready to drink.
f. Record installation date on the filter change sticker
chart, and place behind the sink cabinet door or another
accessible place.
Battery Replacement For LED Indicator Faucet
7. Replace the battery in the faucet LED indicator to reset the filter
change reminder. The battery type is CR2032, and Brondell
provides one with every set of RF-30 filters.
a. Under the faucet handle, locate the black rubber battery
compartment. Grasp it from the sides, and pull down as shown.
b. Remove the old battery from the compartment by lifting the
silver metal tab and sliding the battery out of the rubber
casing. Wait 30 seconds for the residual energy to drain to
reset the indicator.
c. Replace with a new CR2032 battery by sliding the battery
under the silver tab, making sure that the words on the battery
are facing out.
d. Push the black rubber battery compartment back up into the
faucet handle.
e. The indicator will blink red once then blue once, then it will
function as normal.
Step 6a
1
2
3
Step 4b
MAINTENANCE
Filter Replacement
Loading ...
Loading ...
Loading ...