Chapter 74 IP Source Guard
XGS2220 Series User’s Guide
550
74.3.1 Add/Edit IPv4 Source Guard Static Binding
Use this screen to manage static bindings for DHCP snooping and ARP inspection. Static bindings are
uniquely identified by the MAC address and VLAN ID. Each MAC address and VLAN ID can only be in
one static binding. If you try to create a static binding with the same MAC address and VLAN ID as an
existing static binding, the new static binding replaces the original one. Click Add/Edit, or select an entry
and click Add/Edit in the SECURITY > IPv4 Source Guard > IP Source Guard > Static Binding screen to
display this screen.
Figure 435 SECURITY > IPv4 Source Guard > IP Source Guard > Static Binding > Add/Edit (Standalone
Mode)
Figure 436 SECURITY > IPv4 Source Guard > IP Source Guard > Static Binding > Add/Edit (Stacking
Mode)
The following table describes the labels in this screen.
Table 286 SECURITY > IPv4 Source Guard > IP Source Guard > Static Binding > Add/Edit
LABEL DESCRIPTION
IP Address Enter the IP address assigned to the MAC address in the binding.
VLAN Enter the source VLAN ID in the binding.
MAC Address Enter the source MAC address in the binding. If this binding applies to all MAC addresses,
select Any.
Port Specify the ports in the binding. If this binding has one port, select the first radio button and
enter the port number in the field to the right. In Stacking mode, the first field is the slot ID and
the second field is the port number. If this binding applies to all ports, select Any.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to
save your changes to the non-volatile memory when you are done configuring.
Clear Click Clear to clear the fields to the factory defaults.
Cancel Click Cancel to not save the configuration you make and return to the last screen.