Adjustment
Program the Travel
Travel limits regulate the points at which the door will stop when moving
up or down.
While programming the travel, the UP and DOWN buttons can be used to
move the door as needed. During the Automatic Force Setup, the door will
automatically open and close.
1. Press and hold the Adjustment Button until the UP Button begins to
flash and/or a beep is heard. The Safety Reversing Sensors will be
disconnected during the Program the Travel process.
2. Press and hold the UP Button until the door is in the desired UP
position.
3. Once the door is in the desired UP position press and release the
Adjustment Button. The garage door opener lights will flash twice and
the DOWN Button will begin to flash.
4. Press and hold the DOWN Button until the door is in the desired
DOWN position.
5. Once the door is in the desired DOWN position press and release the
Adjustment Button. The garage door opener lights will flash twice.
Program the Travel is now complete. If the garage door opener lights
flash 5 times, then programming has timed out and the Travel Limits
have not been set. Please restart the Program the Travel process.
Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or KILLED
by a closing garage door.
Incorrect adjustment of garage door travel limits will interfere with
proper operation of safety reversal system.
After ANY adjustments are made, the safety reversal system MUST
be tested. Door MUST reverse on contact with 1-1/2" high (3.8 cm)
object (or 2x4 laid flat) on floor.
To prevent damage to vehicles, be sure fully open door provides
adequate clearance.
1
2
3
5
4
UP
Button
Adjustment
Button
DOWN
Button
Programming Buttons
To prevent possible SERIOUS INJURY or DEATH, after ANY changes to
the door profile, reprogram limits.
Automatic Force Set Up
Once both the up and down positions have been manually set, the Safety
Reversing Sensors will reconnect and become operational. Then, the opener
will enter a force-sensing operation by automatically moving the door open
and close. The garage door opener will sound an audible and visual alert
before automatically opening and closing the door. The garage door opener
will beep three times, confirming that the Automatic Force Setup completed
successfully. Adjustment is complete.
If you hear one long beep after the door attempts to move, then the
Automatic Force Set Up has not completed successfully. Please start over at
step 1 of Program the Travel.