Hikvision DS-2CD6825G0/C-IVSB Dual-Lens People Counting Network Camera

User Manual - Page 86

For DS-2CD6825G0/C-IVSB.

PDF File Manual, 92 pages, Read Online | Download pdf file

DS-2CD6825G0/C-IVSB photo
Loading ...
Loading ...
Loading ...
7.
Click Save to save the rule conguraon.
8.
Set arming schedule. See Set Arming Schedule .
9.
Set linkage method. See Linkage Method Sengs .
10.
Oponal: Set data opmizaon parameters. Click Save aer seng the parameters.
Height Filtering
Enable the funcon and set a height value. Persons and objects whose height is below the
set value will not be counted as a valid target.
Children Data Upload
Enable the funcon and set a height value. Persons and objects whose height is higher than
this set value will not be counted as children.
11.
Oponal: Set people counng data uploading parameters. Refer to Data Uploading for details.
12.
Oponal: Set reverse counng alarm.
1) Click Reverse Counng Alarm to enter the interface. Check Enable Reverse Entering Alarm
to enable the funcon.
2) Set the arming schedule and linkage method.
3) Click Save.
When the detecon target leaves the detecon area in the direcon opposite to the detecon
direcon, an alarm will be triggered.
13.
Oponal: Set overlay and capture parameters. Refer to Overlay and Capture for details.
14.
Oponal: Set people counng advanced parameters for detecon accuracy improvement and
maintenance. Refer to Advanced Sengs for details.
15.
Oponal: Set shield region.
The shield region allows you to set the specic region in which the set smart funcon rule is
invalid.
1) Select Shield Region.
2) Click
to draw shield region. Repeat this step above to set more shield regions.
3) Select and click on the drawn region, then click to delete the selected drawn region.
4) Click to delete all drawn regions.
5) Click Save.
What to do next
Go to Applicaon Display to view detailed people counng data analysis. For detailed sengs,
refer to View People Counng Data .
Auto Calibraon
Camera automacally calculates the installaon parameters and complete calibraon.
Steps
1.
Select calibraon mode as Auto.
2.
Drag the calibraon area (the green rectangle in image) to cover a level area of the ground.
Network Camera User Manual