Note
Draw three segments of the rule from near to far to cover all of the detection area.
6.
Check to enable Filter by Pixel. Then Draw max size and min size rectangles to lter the
target among human, vehicle, animal, and others. Only the target whose size is between
the Max. Size and Min. Size value will trigger the alarm.
Note
You can draw the max. size and min. size rectangles according to the real target in the
scene. The recommended size is 1.2 times of the target.
The height of the rectangle is a more important factor as it is the main difference to
tell apart a human and an animal.
Click to copy the same settings to other rules.
7.
Click Save.
8.
Refer to
Set Arming Schedule
for setting scheduled time. Refer to
Linkage Method
Settings
for setting linkage method.
6.3.3 Set the Scene Auto-Switch
The device support patrol tracking for multiple important scenes. The alarm will be
triggered if the rule is broken during patrol sequence.
Before You Start
Finish scene settings in advance. See
Set Detection Scenes and Tracking
for conguration
instructions.
Steps
1.
Go to VCA > Scene Auto-Switch to congure this function.
2.
Set the scene patrol sequence.
Scene Name
Select a scene name from the drop down list.
Duration
Set the dwell time of the scene when doing patrol tracking.
3.
Click the up, down arrow to adjust the patrol sequence.
4.
Click Save.
6.3.4 Set Polling Plan
Both the optical channel and the thermal channels support the perimeter protection. Set
the working shift for each channel.
Before You Start
The detection scenes and rules should be congured in advance for both channels.