117
Figure 9-27 Area Temperature Comparison Alarm
c) Select the comparison rule.
d) Set the temperature difference threshold value.
Example: select Area 1 and Area 11, and set the comparison rule as
Above (Max. Temperature), and set the temperature difference
threshold to 5 °C. The device alarms when the difference of two areas'
maximum temperature is above 5 °C.
9.4.3 Linkage Method
Purpose:
Set the linkage method of the alarm.
Steps:
1. Enter Configuration > Temperature Measurement > Linkage Method.
2. Set the arming schedule and linkage method.
Arming Schedule: Click on the time bar and drag the mouse to select the
time period.
Linkage Method: Click Linkage Method and check the checkbox to select the
linkage method. Audible warning, notify surveillance center, send email,
upload to FTP, trigger channel and trigger alarm output are selectable. You
can specify the linkage method when an event occurs.
3. Click Save to save the settings.
After the settings, you can view the current temperature and humidity on the top of