115
Figure 9-25 Alarm Rule Settings (Point)
b) Set the Alarm Rule.
c) Set the Alarm Temperature, Pre-Alarm Temperature, and Tolerance
Temperature.
d) Set the Filtering Time.
e) Set the Pre-Alarm Output and Alarm Output with the connected alarm
sensor and alarm device.
Example: select Alarm Rule as Above (Average Temperature), set the Alarm
Temperature to 50 °C and Filtering Time as 5 s, and then the device alarms
when its average temperature keeps being above 50 °C for over 5 s.