PN 4897580 September 2017 Rev. 2, 3/20
©2017-2020 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.
All product names are trademarks of their respective companies.
T6-600/T6-1000/
T6-1000 PRO
Electrical Tester
with FieldSense Technology
Safety Information
A Warning identifies conditions and procedures that are dangerous
to the user.
XW Warning
To prevent possible electrical shock, fire, or personal
injury:
• Read
all safety information before you use the Product.
• Carefully read all instructions.
• Do not alter the Product and use only as specified, or the
protection supplied by the Product can be compromised.
• Do not use the Product around explosive gas, vapor, or
in damp or wet environments.
• Comply with local and national safety codes. Use
personal protective equipment (approved rubber gloves,
face protection, and flame-resistant clothes) to prevent
shock and arc blast injury where hazardous live
conductors are exposed.
• Examine the case before you use the Product. Look for
cracks or missing plastic. Carefully look at the insulation
around the terminals.
• T6-600/T6-1000: Examine the battery door decal for
damage to this insulator. Look for any cracks, holes, or
evidence of delamination. This insulator houses a
laminated foil that provides a capacitive current path for
the FieldSense function. This insulator provides a means
2-Year Limited Warranty.
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com

of protection against electric shock when the COM probe
test lead (black) is installed into the back case.
• The battery door must be closed and locked before you
operate the Product.
• Do not use the Product if it is damaged.
• Disable the Product if it is damaged.
• Do not use the Product if it operates incorrectly.
• Do not use test leads if they are damaged. Examine the
test leads for damaged insulation or exposed metal.
Check test lead continuity.
• Limit operation to the specified measurement category,
voltage, or amperage ratings.
• Do not touch voltages >30 V ac rms, 42 V ac peak, or
60 V dc.
• Use the correct terminals, function, and range for
measurements.
• Do not apply more than the rated voltage, between the
terminals or between each terminal and earth ground.
• Do not exceed the Measurement Category (CAT) rating of
the lowest rated individual component of a Product,
probe, or accessory.
• Keep fingers behind the finger guards on the probes.
• Hold the Product behind the tactile barrier. See the Quick
Reference Guide for this Product.
• T6-600/T6-1000: To use the FieldSense Ground Contact,
make sure the – test probe (BLACK) is stowed in the
storage location in the back case before a FieldSense
measurement. See the Quick Reference Guide for this
Product.
• Disconnect power and discharge all high-voltage
capacitors before you measure resistance or continuity.
• Replace the batteries when the low battery indicator
shows to prevent incorrect measurements.
• Do not operate the Product with covers removed or the
case open. Hazardous voltage exposure is possible.
• Have an approved technician repair the Product.
• Use only specified replacement parts.
For safe operation and maintenance of the Product:
• Remove batteries to prevent battery leakage and damage
to the Product if it is not used for an extended period.
• Repair the Product before use if the battery leaks.
• Be sure that the battery polarity is correct to prevent
battery leakage.
• Clean the case with a damp cloth and detergent. Do not
use abrasives or solvents.
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com

Safety Specifications
Battery............................... 2 x AA (IEC LR6)
Temperature
Operating........................ -10 °C to +50 °C (+14 °F to +122 °F)
Storage........................... -30 °C to +60 °C (-22 °F to +140 °F)
Operating Relative Humidity
0 % to 95 %.................... 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %.................... 30 °C to 40 °C (86 °F to 104 °F)
0 % to 45 %.................... 40 °C to 50 °C (104 °F to 122 °F)
Altitude
Operating........................ 2000 m
Storage........................... 10 000 m
Safety
General........................... IEC 61010-1: Pollution Degree 2
Measurement .................IEC 61010-2-032, IEC 61010-2-033
T6-600.......................... CAT III 600 V
T6-1000/T6-1000 Pro... CAT IV 600 V / CAT III 1000 V
Electromagnetic Compatibility (EMC)
International.................... IEC 61326-1: Portable Electromagnetic
Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses
conductively-coupled radio frequency energy that is necessary
for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments
other than domestic and those directly connected to a low-
voltage power supply network that supplies buildings used for
domestic purposes. There may be potential difficulties in
ensuring electromagnetic compatibility in other environments
due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential
environments and may not provide adequate protection to radio
reception in such environments.
Korea (KCC)................... Class A Equipment (Industrial
Broadcasting & Communication
Equipment)
Class A: Equipment meets requirements for industrial
electromagnetic wave equipment and the seller or user should
take notice of it. This equipment is intended for use in business
environments and not to be used in homes.
USA (FCC) ..................... 47 CFR 15 subpart B. This product is
considered an exempt device per clause
15.103.
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com

Symbols
Symbol Description
W
WARNING. RISK OF DANGER.
X
WARNING. HAZARDOUS VOLTAGE. Risk of electric
shock.
Consult user documentation.
FieldSense Measurement: Fluke voltage/current sensing
technique.
T
Double Insulated
,
Application around and removal from uninsulated
hazardous live conductors is permitted.
Earth
Both direct and alternating current
Battery
Measurement Category II is applicable to test and
measuring circuits connected directly to utilization points
(socket outlets and similar points) of the low-voltage
MAINS installation.
Measurement Category III is applicable to test and
measuring circuits connected to the distribution part of
the building’s low-voltage MAINS installation.
Measurement Category IV is applicable to test and
measuring circuits connected at the source of the
building’s low-voltage MAINS installation.
P
Conforms to European Union directives.
)
Certified by CSA Group to North American safety
standards.
Conforms to relevant South Korean EMC standards.
Conforms to relevant Australian EMC standards.
~
This product complies with the WEEE Directive marking
requirements. The affixed label indicates that you must
not discard this electrical/electronic product in domestic
household waste. Product Category: With reference to
the equipment types in the WEEE Directive Annex I, this
product is classed as category 9 "Monitoring and Control
Instrumentation" product. Do not dispose of this product
as unsorted municipal waste.
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com

LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for
two years from the date of purchase. This warrant
y does not cover fuses,
disposable batteries, or damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling. Resellers are
not authorized to extend any other warranty on Fluke’s behalf. To obtain
service during the warranty period, contact your nearest authorized service
center to obtain return authorization information, then send the product to that
Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES,
SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR
IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING
FROM ANY CAUSE OR THEORY. Since some states or countries do not allow
the exclusion or limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may not apply to you.
SOFTWARE NOTICE
Copyright 2014, Texas Instruments Incorporated. All rights reserved.
Redistribution and use in source and binary forms, with or without modification,
are permitted provided that the following conditions are met:
• Redistributions of source code must retain the above copyright notice, this
list of conditions and the following disclaimer.
• Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation and/
or other materials provided with the distribution.
• Neither the name of Texas Instruments Incorporated nor the names of its
contributors may be used to endorse or promote products derived from this
software without specific prior written permission.
Copyright
2009-2015 ARM Limited. All rights reserved. Redistribution and
use in source and binary forms, with or without modification, are permitted
provided that the following conditions are met:
• Redistributions of source code must retain the above copyright notice, this
list of conditions and the following disclaimer.
• Redistributions in binary form must reproduce the above copyright notice,
this list of conditions and the following disclaimer in the documentation and/
or other materials provided with the distribution.
• Neither the name of ARM nor the names of its contributors may be used to
endorse or promote products derived from this software without specific
prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
DISCLAIMED. IN NO EVENT SHALL COPYRIGHT HOLDERS AND
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT
OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct.com