FLUKE T6-600/C60 Electrical Tester with FieldSense technology, 1000 V

User Manual for the Fluke T6-600/C60 Electrical Tester with FieldSense technology, 1000 V

For T6-600/C60.

PDF File Manual, 2 pages, Read Online | Download pdf file

T6-600/C60 photo
HOLD
3
2
1
5
7
6
200 A
CAT
1000 V
CAT 600 V
4
HOLD
200 A
CAT
1000 V
CAT 600 V
AUTO
SELECT
T6-1000
ELECTRICAL TESTER
5
2
7
3
1
4
6
True
RMS
Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated leads ()
PN 4462973
TP1 Single Probe, Flat-Tip, Red PN 648128
TP1 Single Probe, Flat-Tip, Black PN 648102
TP38 Single Probe, Round-Tip, Red PN 1276841
TP38 Single Probe, Round-Tip, Black PN 1276852
Battery Door PN 4944370
Battery Door Screw PN 1618578
Use only specied replacement parts
Quick Reference Guide
Model T6-1000 Model T6-600
Function
Requires
Test Leads
Range Range Resolution Accuracy
[1]
FieldSense
Voltage ac true-rms
No 1000 V 600 V 1 V
±(3 % + 3 counts)
45 Hz to 66 Hz
[2] [3]
FieldSense
Current ac true-rms
No 200.0 A 200.0 A 0.1 A
±(3 % + 3 counts)
45 Hz to 66 Hz
FieldSense
frequency (Hz)
No 45 Hz to 66 Hz 1 Hz ±(1 % + 2 counts)
[3]
Voltage ac true-rms Yes 1000 V 600 V 1 V
±(1.5 % + 2 counts)
45 Hz to 66 Hz
Voltage dc Yes 1000 V 600 V 1 V ±(1 % + 2 counts)
Resistance
Yes 2000 Ω 2000 Ω 1 Ω
±(1 % + 2 counts)Yes 20.00 kΩ 0.01 kΩ
Yes 100.0 kΩ 0.1 kΩ
[1] Accuracy: ±( [ % of reading] + [number of least signi󰘰cant digits] ). Accuracy is speci󰘰ed for 1 year after calibration, at
18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are accoupled, RMS responding.
[2] Add 3 % typical without an external ground connection. External ground connection required for user wearing insulated
gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is speci󰘰ed from 16 V to 100 % of range.
Fork opening 17.8 mm
Temperature
Operating
Storage
-10 °C to +50 °C (+14 °F to +122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating
Storage
2000 m
10 000 m
Relative Humidity 0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life 2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function
Temperature coe󰘲cient 0.1 x (speci󰘰ed accuracy) / °C for <18°C or >28 °C (<64.4 °F or >82.4 °F)
T6-600/T6-1000
Electrical Tester
with FieldSense Technology
» See
Safety Information
.
Go to www.󰘱uke.com to register your product and 󰘰nd more information, or
download this Quick Reference Guide in other languages.
PN 4897598 September 2017 Rev. 4, 7/18
© 2017-2018 Fluke Corporation. All rights reserved.
Speci󰘰cations are subject to change without noti󰘰cation.
Fork Opening 17.8 mm
Overview
Wire Position
1 Wire Only
Finger Guard
For safe operation, hold the
Tester behind the 󰘰nger guard.
Display
Model T6-1000
Model T6-600
X Hazardous Voltage ≥30 V
Function Selection/On/O󰀨
Auto O󰀨
15 min
FieldSense Ground Contact
Test Probes/Storage Dock
Symbols
W
WARNING. RISK OF DANGER. Test with fork and FieldSense ground contact.
»
Consult user documentation. Test with fork and ground probe.
Y
Hazardous voltage ≥30 V. Test with probes.
Battery full charge.
FieldSense Measurement: Fluke voltage/current
sensing technique.
Battery low. Replace.
J
Good earth ground connection.
Back light
J
No earth ground connection.
Specications
HT6 Belt Holster
TPAK Hanger
PRV240FS Proving Unit
AC285 SureGrip™ Alligator Clips
AC220 SureGrip™ Alligator Clips
C60 softcase
.Lead Replacement
Accessories
● HT6 ●
Replacement Parts
Wire must contact
the bottom of the
fork opening.
1.888.610.7664 sales@GlobalTestSupply.com
Fluke-Direct
.com
Loading ...

Other documents for FLUKE T6-600/C60

The following documents are available:
User Manual
  • User Manual for the Fluke T6-600/C60 Electrical Tester with FieldSense technology, 1000 V - (English) Read Online | Download pdf
Specification
  • Datasheet for the Fluke T6-600/C60 Electrical Tester with FieldSense technology, 1000 V - (English) Download
Photos

Specifications