Note
AIN1 and AIN2 are defaulted to connect door contact. Door contact connected to
AIN1 detects status of the lock that connected to NC1/NO1; Door contact connected
to AIN2 detects the status of the lock connected to NC2/NO2.
1.3.3 Exit Buon Wiring
Figure 1-14 Exit Buon Wiring
Note
AIN3 and AIN4 are set as default for connecng exit buon. Exit buon connected to
AIN3 opens the lock connected to NC1/NO1; Exit buon connected to AIN4 controls
the lock that connected to NC2/NO2.