CARE & USE/INSTALLATION
|
47
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
Max BTU for all
Appliances on line
10 360,000
20 245,000
30 198,000
40 169,000
50 150,000
60 135,000
70 123,000
80 115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL-SPECIFIC BTU OUTPUTS
MODEL ROTISSERIE TRIDENT TOTAL INPUT
LF36AT(F)R 1 @ 14,000 3 @ 23,000 83,000 Btu/Hr