Steps
1. Go to System → Storage Management → Storage HDD → Array Management .
2. Rebuild an array.
Table 9-2 Rebuilding Method
Rebuilding Method Descripon
Auto Rebuild There should be a hot spare disk in the array,
and the hot spare disk capacity is not less than
the disk with the minimum capacity in the
array. Click in Operaon column under
Physical Disk to set a hot spare disk.
When an HDD in the array in the array is not
working, the hot spare disk would be
acvated, and the array would be
automacally rebuilt.
Note
Aer auto rebuild nishes, it is recommended
to install another HDD, and congure it as the
hot spare disk.
Manual Rebuild If there is no hot spare disks in the array, you
have to manually rebuild the array.
Go to System → Storage Management →
Storage HDD → Array Management , and
select the hot spare disk in the list to rebuild.
9.2.3 Delete Array
Go to System → Storage Management → Storage HDD to click to delete the selected array.
9.2.4 View Firmware Info
You can view array rmware informaon and set the background task speed.
Before You Start
Ensure disk array is enabled.
Steps
1. Go to System → Storage Management → Storage HDD → Array Management .
2. Click Firmware Info.
3. Oponal: Set Back Ground Task Speed.