XO UIM1565SP 15 Inch Built-In Indoor/Outdoor Gourmet Ice Maker with Crystal Clear Cubes,

User Guide - Page 29

For UIM1565SP.

PDF File Manual, 32 pages, Read Online | Download pdf file

UIM1565SP photo
Loading ...
Loading ...
Loading ...
sanitizing cont.
Make sure the switch is in the “OFF” position and restore power by plugging the unit in or turning on the breaker.
AUTOMATIC SANITIZING:
Start the automatic sanitizing process by turning the switch to the “WASH” position. This will also sanitize the piping.
The automatic sanitizing cycle takes 21 minutes to complete. After it is finished set the switch in the “OFF” position.
RINSING:
If any disinfectant solution remains in the water tank, remove the drain plug to empty the tank.
Re-install the drain plug, pour one quart of clean water into the water tank and run “WASH” again for 10 minutes.
Do NOT wipe the interior dry.
Turn on the “ICE” function and the unit will resume making ice.
Discard the first batch of ice after sanitizing.
29
Proper maintenance assures better ice and longer product life.
Shown below is a recommended service schedule to maintain your ice maker at peak performance.
Failure to provide maintenance as prescibed in this manual may void warranty.
The intervals shown are based on average conditions, your unit may require more frequent
maintenance based on your particular installation, such as areas where hard water, dust or
salt air are present.
RECOMMENDED SCHEDULE:
IMPORTANT NOTE:
If your ice maker has been winterized, you must wash, sterilize and clean/descale it
thoroughly before returning it to service to ensure that any detergents or chemicals
have been completely flushed from the system.
Always discard the first batch of ice made after restarting.
maintenance schedule
MAINTENANCE
CLEAN EXTERIOR
WASH INTERIOR
STERILIZE
CLEAN/DESCALE
VACUUM CONDENSER
CHECK ICE QUALITY
WEEKLY MONTHLY QUARTERLY ANNUALLY AT START-UP
CHANGE WATER FILTER
Loading ...
Loading ...
Loading ...