INSTALLING THE XOUIM1565S without a drain pump.
Position the ice maker in front of the opening. Level the unit using the leveling legs.
Wash and flush the water supply tube and connect the unit to the cold water isolation valve.
Prepare the drain. The drain must be pitched downward at a drop of 1/4” per foot to drain properly.
Horizontal runs of 5’ or more must be anchored to a wall for support to prevent sagging.
A sanitary trap and air gap must be installed in the line prior to entering the home’s drain system.
The trap prevents sewer gas from flowing back to the ice maker.
The air gap device prevents siphoning drain water back into the ice maker.
Cut the 5/8” ID drain hose (not supplied) to the required length. Immerse the hose in warm water to make
installation easie
hose to the drain using hose clamps.
r, then using a threaded hose barb connection sealed with teflon tape, connect the drain
Turn the water supply on and check to ensure there are no leaks.
If there are no leaks, plug the unit into the electrical outlet.
Press the switch to the “ICE” position. The compressor will run approximately 3 - 5 minutes.
Slide the unit back into it’s final position and recheck to ensure it is level.
REMEMBER to adhere to all local building codes and regulations
with gravity drain
DRAIN VENT
THE DRAIN POINT
MUST BE LOWER
THAN THE DRAIN
OUTLET OF THE
ICE MAKER
AI
DEVICE
R GAP
SANITARY TRAP
If you purchase a gravity drain unit
and find you need one with a pump
the XOUIM1565S can easily be
retrofitted with one in the field.
Simply order a XOUIMPUMP from
www.xoappliance.com