Chapter 4 Wiring
You can connect the NC/NO and COM terminal with the door lock, connect the SEN and GND
terminal with the door contact and the BTN/GND terminal with the exit buon.
Note
●
If cable size is 18 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 20 m.
●
If the cable size is 15 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 30 m.
●
If the cable size is 12 AWG, you should use a 12 V power supply. And the distance between the
power supply and the device should be no more than 40 m.
●
The external card reader, door lock, exit buon, and door magnec need individual power
supply.
4.1 Terminal Descripon
The terminals contains power input and door lock.
The descripons of the terminals are as follows:
Table 4-1 Terminal Descripons
Group No. Funcon Color Name Descripon
Group A A1 Power Input Red +12 V 12 VDC Power
Supply
A2 Black GND Ground
Group B B1 Door Lock White/Purple NC Lock Wiring
(NC)
B2 White/Yellow COM Common
B3 White/Red NO Lock Wiring
(NO)
B4 Yellow/Green SENSOR Door Contact
B5 Black GND Ground
B6 Yellow/Grey BUTTON Exit Door
Wiring
DS-K1T320 Series Face Recognion Terminal User Manual