6 49-5000874 Rev. 1
Using the Air Conditioner
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for
freezing outdoor conditions.
It must not be used when the outdoor temperature is
below freezing (32°F).
Control Panel Lights On/Off Feature
This air conditioner has a control panel lights on/off
feature where its lights will turn off when there is no
activity with the controls for over one minute. To wake up
the controls, press any pad on the controls and the lights
will come on to show the previous settings.
To turn this feature off, press LED button on remote
control, the unit will beep to signal the successful toggle
of the feature on and off.
USING THE AIR CONDITIONER
Remote Control
ŶTo ensure proper operation, aim the remote control at
the signal receiver on the air conditioner.
ŶThe remote control signal has a range of up to 20 feet.
ŶMake sure nothing is between the air conditioner and
the remote control that could block the signal.
ŶMake sure batteries are fresh and installed correctly as
indicated on the remote control.
Cool Mode
8VHWKH&RROPRGHDWLow, Med, High or Auto fan
VSHHGIRUFRROLQJ8VHWKHTemperature Increase + /
Decrease - pads to set the desired temperature between
60°F and 86°F in 1°F increments.
An electronic thermostat is used to maintain the room
temperature. The compressor will cycle on and off and
also change operating speeds to keep the room at
the set level of comfort. Set the thermostat at a lower
number and the indoor air will become cooler. Set the
thermostat at a higher number and the indoor air will
become warmer.
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan setting
to a Cool setting, it may take approximately 3 minutes
for the compressor to start and cooling to begin.
Cooling Descriptions
For Normal Cooling—Select the Cool mode and
High or Med fan with a middle set temperature.
For Maximum Cooling—Select the Cool mode
and High fan with a lower set temperature.
For Quieter and Nighttime Cooling—Select the
Cool mode and Low fan with a middle set temperature.
Eco Pad
Controls the fan and compressor.
ON—The fan will cycle on and off with the compressor.
This may result in wider variations of room temperature.
NOTE: the fan may continue to run for a short time or
may pulse intermittently after the compressor cycles off
to sample the room air. OFF—The fan runs all the time,
while the compressor cycles on and off.
Fan Only Mode
8VHWKH)DQ2QO\0RGHDW$XWR/RZ0HGRU+LJK
fan speed to provide air circulation and filtering without
cooling. Since fan-only settings do not provide cooling,
a Set temperature cannot be entered. The room
temperature will appear in the display.
Auto Fan Mode
Set to Auto for the fan speed to automatically set to the
speed needed to provide optimum comfort settings with
the set temperature.
If the room needs more cooling, the fan speed will
automatically increase. If the room needs less cooling, the
fan speed will automatically decrease.
Control Panel Sound On/Off Feature
This air conditioner has a control panel sounds on/off
feature where the sounds that occur when a button on
the user interface is touched can be turned on or off.
This feature is turned on by default, meaning that the
air conditioner will make a sound when any button is
pressed on the user interface. To turn this feature off so
as to make the button presses silent, press and hold the
Filter button on the user interface for 5 seconds. The air
conditioner will beep to signal the successful toggle of
this feature on and off.
Loading ...