17
Gas Shut-off Valve (not included)
Gas Shut-off Valve
P
X
GAS INLET
Pressure Regulator
Pressure Regulator
Since service pressure may fluctuate with local demand, every gas cooking
range must be equipped
with a pressure regulator on the incoming service line for safe and efficient operation.
The pressure regulator preinstalled on the range has a gas inlet of 1/2" NPT for the 30", 36" & of 3/4"
NPT for the 48"'.
Pressure regulator can withstand a maximum input pressure of 0.5 psi (3.5 kPa), and is set at 5"
WC outlet pressure when used on NATURAL GAS and 10" WC outlet pressure when used on
LIQUID PROPANE.
The supply line must be equipped with
an approved external gas shut-off valve located near the range
in an accessible location. Do not block access to the shut-off valve. Refer to the illustration below.
A 3/4" (19 mm) ID gas supply line must be connected to the range. If local codes permit, a certified, 3'
(.9 m) long, 1/2" (13 mm) or 3/4" (19 mm) ID flexible metal gas line is recommended to connect the
unit’s 1/2" NPT (30", 36") or 3/4" NPT (48",60'') female inlet to the gas supply line. Pipe joint
compounds suitable for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected from the gas supply piping system during
must be isolated from the gas supply piping system by closing its individual manual shutoff valve
during any pressure testing of the system at test pressures equal to or less than 0.5 psi (3.5 kPa).