31. Install all the remaining anchor bolts
around the bottom flange of the entire
Safety Shelter. Once installed, make
sure to torque them to 40 Ft-lbs. See
instruction in Step 5 of this manual and
follow the Manufacturers Instructions. If
needed a steel punch or large screw
driver can be used to help align the holes
in the base flanges with the holes in the
concrete.
It is ok to install the six anchor bolts at
the base of the Front Wall. However,
before you torque them down, remove
the nuts and washers. In a later Step
these will be reinstalled.
32. Tighten all bolts around the roof exterior
and interior flanges to 31 Ft-lbs.
33. Tighten all bolts in every wall flange to 31
Ft-lbs.