E0 ash every 4 seconds temperature sensor issue:
Contact Leisure-Tec on 1300 07 2018
E1 ash every 4 seconds - low voltage & Battery Protection:
An E1 will occur when the battery protection level has been reached.
i.e input voltage to low for protection setting, check power source voltage.
Try on dierent power source (vehicle or 240V AC power).
If changing power source xed issue, then possible issue with original power source.
Ensure cabling between fridge and battery is at least 1.5 mm
2
,
if the distance is more than 2 metres use at least 2.5 mm
2
cable.
Try turning on your vehicle so that the battery is being charged. E1 should automatically clear
after a few minutes, and the fridge will resume normal operation, when the power source voltage
increases above the battery protection cut o point.
E2 ashes every 4 seconds - fan issue:
Fan is drawing too many amps (over 0.6 amps), replace fan.
Contact Leisure-Tec on 1300 07 2018
E3 ashes every 4 seconds - compressor start issue:
Unplug cable and allow unit to rest for 10 minutes.
Try on dierent power source (vehicle or 240 V AC power).
Electronic box fault.
Compressor fault.
If changing from 240v AC to 12v DC power or vice versa, if the change is done too quickly
without switching o the unit; the unit will show an error.
Just wait 5 minutes and it will automatically correct and run normally.
E4 ashes every 4 seconds - low motor speed:
Reduce products/items inside unit.
Move so unit is in a lower ambient temperature,
clean vents/ensure clear air ow over compressor.
Fan fault.
If changing from 240v AC to 12v DC power or vice versa, if the change is done too quickly
without switching o the unit; the unit will show an error.
Just wait 5 minutes and it will automatically correct and run normally.
E5 ashes every 4 seconds -
over temperature:
Ambient temperature too high.
Clean vents/ensure clear air ow
over compressor.
Fan fault.
NOTE:
The status indicator will be green if running normal.
If it changes to a ashing orange light, this indicates
that there is a change in status. There will also be
a status indicator code shown on the LED display.