Napoleon BIPRO665RBNSS-3-PL Built-in Prestige PRO 665 RB with Infrared Rear Burner

Manual - Page 19

For BIPRO665RBNSS-3-PL.

PDF File Manual, 68 pages, Download pdf file

Loading ...
Loading ...
Loading ...
19
EN
www.napoleon.com
N415-0542CE-GB-DE FEB 01.22
BUILT-IN UNIT OPENING DIMENSIONS
MODEL OPENING DIMENSIONS NOTES
W D H
BIPRO665 38”
965mm
20 5/8”
524mm
8 7/8”
225mm
SIDE BURNER
N370-0504 -LPG
N370-0505 -NAT
12 3/4”
324mm
16 1/2”
419mm
4 1/2”
114mm
OPENING OF AT LEAST
32cm
2
MUST BE PROVIDED FOR COMBUS
TION
AIR FOR SIDE BURNER.
WARNING! This grill is designed for Non-combusble enclosures only, and must be installed and
serviced by a qualied installer to local codes.
WARNING! Enclosures must be built from non combusble materials (cered class A to EN
13501-1 standard).
!
!
W
H
D
W
H
D
BUILT-IN SIDEBURNER
GAS INLET OPENING
NON-COMBUSTIBLE MATERIAL
OUTDOOR GFI ELECTRICAL OUTLET
REC
OMMENDED - LOCATE ON SAME SIDE
OF GRILL AS ROTISSERIE BRACKET.
GAS INLET OPENING
127mm
44mm
ELECTRICAL BOX OPENING
IF THE COUNTER TOP IS OVERHANGING THE EDGE OF
THE ENCLOSURE THE CORNERS MUST BE NOTCHED
A MINIMUM OF 30 mm TO ACCOMMODATE THE
CONTROL PANEL END CAPS.
NOTE: ACCESSORY
FRAMES OVERLAP
OPENING BY 4cm
ON ALL 4 SIDES.
WARNING! CABINET FRAME, CABINET AND COUNTER TOP
MUST BE MADE FROM NON-COMBUSTIBLE MATERIAL.
!
!
864mm
RECOMMENDED
ELECTRICAL OPENING
2" (51mm)
4” (102mm)
4” (102mm)
If enclosure houses an LPG cylinder, this construcon
must comply with the built-in cylinder enclosure
instrucons. Refer to ‘Gas Connecon’.
!
Loading ...
Loading ...
Loading ...