123B/124B/125B
Users Manual
86
The Fluke 12xB series, including standard accessories, conforms to the EEC directive 2004/108/EC for EMC immunity, as
defined by EN61326-1: 2006, with the addition of the table below.
Trace disturbance with STL120-IV
Frequency Field strength
No visible
disturbance
Disturbance less than
10% of full scale
80 MHz to 1 GHz 10 V/m 1 V/div to 200 V/div 500 mV/div
1.4 GHz to 2 GHz 3 V/m All ranges -
2 GHz to 2.7 GHz 1 V/m All ranges -
(-) = no visible disturbance
Ranges not specified may have a disturbance of >10 % of full scale.